21
Experiment 4: TLC and HPLC of Nitroanilines

nitroanilne TLC

Embed Size (px)

Citation preview

Page 1: nitroanilne TLC

Experiment 4:

TLC and HPLC of Nitroanilines

Page 2: nitroanilne TLC

Objectives

To learn the analytical techniques of Thin Layer Chromatography (TLC) and HPLC chromatography.

To use these techniques to separate and identify o-nitroaniline and p-nitroaniline in sample mixture.

To identify the compounds based TLC Rf and HPLC Rt.

To investigate the effect of solvent system polarity on TLC Rf values and HPLC retention times.

Page 3: nitroanilne TLC

Before coming to lab…

Prepare the Pre-lab notebook entry for this experiment!

It is *highly recommended* that you watch the following link prior to coming to lab!http://www.youtube.com/watch?v=EUn2skAAjHk

Page 4: nitroanilne TLC

NITROANILINE STRUCTURES

NH2

NO2

NH2

NO2

p-nitroaniline

MF: C6H6N2O2

MW: 138.13 g/mol

mp: 147-151oC

hazards: Toxic if ingested

Toxic if inhaled

uses: Organic dyes

dipole moment: 3.00 D

o-nitroaniline

MF: C6H6N2O2

MW: 138.13 g/mol

mp: 70-74 oC

hazards: Toxic if ingested

Toxic if inhaled

uses: Organic dyes

dipole moment: 2.27 D

Page 5: nitroanilne TLC

POLARITY OF NITROANILINES

N

N

N

N

p-nitroanilinedipole moment (): 3.00 D

o-nitroanilinedipole moment (): 2.27 D

H HO

O

H H

O O

LARGER = MORE POLAR SMALLER = LESS POLAR

Page 6: nitroanilne TLC

ANALYTE POLARITY VS. STATIONARY PHASE

Si O

OH

Si

OH

O Si

OH

O Si

OH

O Si

OH

O Si

OH

Silica (Stationary phase)

Si O

OH

Si

OH

O Si

OH

O Si

OH

O Si

OH

O Si

OH

Silica (Stationary phase)

Bulk Solvent (Mobile Phase)

ANALYTE

SOLVENT

Polar analyte binds to the SiO2

sites, so it sticks and

moves slowly

Nonpolar analyte doesn’t

bind to SiO2 sites so it doesn’t

stick and moves quickly

Bulk Solvent (Mobile Phase)

Page 7: nitroanilne TLC

THIN LAYER CHROMATOGRAPHY

Supplies for TLC

Analysis

Preparing TLC Plate

Applying

solutions to TLC

plate

Page 8: nitroanilne TLC

THIN LAYER CHROMATOGRAPHY

(Running the Experiment…)

Prepare TLC plate and TLC chamber.

Apply standard solutions and sample solutions to plate.

Develop TLC plate in chamber.

Visualize plate.

Circle spots.

Calculate TLC Rf value for each spot.

o mix p

o mix

filter paper

p

Page 9: nitroanilne TLC

THIN LAYER CHROMATOGRAPHY

Calculation of Rf values

"o" "p"mixxx x

Solvent Front

Origin

Distance solvent migrated = 5.0 cm

Distance "o" migrated = 3.0 cm

Distance "p" migrated = 0.8 cm 0.8 cm

3.0 cm

Rf (B) =

Rf (C) =

Rf (U1) =

Rf (U2) =

= 0.60

= 0.16

= 0.60

= 0.16

3.0 cm5.0 cm

0.8 cm5.0 cm

3.0 cm5.0 cm

0.8 cm5.0 cm

The Rf value is defined as the distance the center of the spot moved divided by the distance the solvent front moved (both measured from the origin)

Page 10: nitroanilne TLC

THIN LAYER CHROMATOGRAPHY

Rf values

Rf values can be used to aid in the identification of a substance by comparison to standards.

The Rf value is not a physical constant, and comparison should be made only between spots run under the same experimental conditions.

Two substances that have the same Rf value may be identical; those with different Rf values are not identical.

Page 11: nitroanilne TLC

HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

(HPLC)

SiO2 packed inside tube

Sample loaded here

HPLC chromatogram produced

Page 12: nitroanilne TLC

HPLC STANDARD CHROMATOGRAMS

o-nitroaniline standardSOLVENT: 50:50 hexane/ethyl acetateRt: 1.074 min

p-nitroaniline standardSOLVENT: 50:50 hexane/ethyl acetateRt: 1.382 min

Page 13: nitroanilne TLC

HPLC SAMPLE CHROMATOGRAM

CompoundRetention

Times of StandardsRetention Times of Sample

o-nitroaniline 1.074 1.074

p-nitroaniline 1.382 1.394

By comparison of sample retention times to standard retention times, the active ingredients can be identified.

Nitroaniline sample mixtureSOLVENT: 50:50 hexane/ethyl acetateo-nitroaniline Rt: 1.074 minp-nitroaniline Rt: 1.394 min

Page 14: nitroanilne TLC

TLC VS. HPLC RESULTS

x

a

b

c

a b c

0 Time

Normal Phase (SiO2)

Normal Phase (SiO2) TLC

Note: A high TLC Rf value = a low HPLC retention time!

Page 15: nitroanilne TLC

FOR MORE INFORMATION...

Please refer to Appendices E and F in the back of your laboratory manual for further explanation of theory behind chromatography.

Page 16: nitroanilne TLC

TABLE 4.1TLC Rf Data

Compound

Rf values in Solvent

System 180:20

hexane/ethyl acetate

Rf values in Solvent

System 250:50

hexane/ethyl acetate

Rf values in Solvent System

3100% ethyl acetate

o-nitroaniline Same #

p-nitroaniline Same #

mixture

TLC Diagrams

(Show measurements for solvent front and all spots in cm)

X X X o mix p

X X X o mix p

X X X o mix p

Don’t forget to give cm measurements for each spot and that of solvent front!

2 decimal places ONLY!

Page 17: nitroanilne TLC

HPLC ChromatogramsNitroaniline sample mixture

SOLVENT: 100% ethyl acetateo-nitroaniline Rt: 0.972 minp-nitroaniline Rt: 1.089 min

Nitroaniline sample mixtureSOLVENT: 50:50 hexane/ethyl acetateo-nitroaniline Rt: 1.074 minp-nitroaniline Rt: 1.394 min

Nitroaniline sample mixtureSOLVENT: 100% ethyl acetateo-nitroaniline Rt: 0.972 minp-nitroaniline Rt: 1.089 min

Nitroaniline sample mixtureSOLVENT: 80:20 hexane/ethyl acetateo-nitroaniline Rt: 1.534 minp-nitroaniline Rt: 3.059 min

Page 18: nitroanilne TLC

TABLE 4.2

HPLC Rt Data

Compound

STANDARD

Rt (min)

SAMPLE

Rt (min)Solvent System

1

SAMPLE

Rt (min) Solvent System

2

SAMPLE

Rt (min) Solvent System 3

o-nitroani

line

p-nitroani

line

Use data from p. 37

Page 19: nitroanilne TLC

SAFETY CONCERNS

Nitroanilines are toxic if inhaled or ingested. Use gloves at all times during the experiment!

All solvents used in today’s experiment are flammable, eye, and skin irritants. Be sure to wash your hands before leaving the laboratory.

Safety goggles are required!

Page 20: nitroanilne TLC

WASTE MANAGEMENT

Place all liquid waste from TLC experiment into container labeled “LIQUID ORGANIC WASTE”.

Place all used TLC capillary tubes in the broken glass container.

Place all TLC plates in yellow trashcan under the supply hood.

TLC chambers should be left with the lids removed in the lab drawer. Do not clean with soap, water, OR acetone!

Page 21: nitroanilne TLC

FOR NEXT LAB…

The pre-lab lab notebook entry for Experiment 5 will be due at the beginning of lab!

Experiment 4 Final Lab Report, along with yellow in-lab notebook pages due at the beginning of lab!