    Narrowband modems PROFIMR400, MR300, MR160

    .

    version 4.122/6/2018

    www.racom.euRACOM s.r.o. Mirova 1283 592 31 Nove Mesto na Morave Czech RepublicTel.: +420 565 659 511 Fax: +420 565 659 512 E-mail: racom@racom.eu

  • Table of ContentsIntroduction .......................................................................................................................................... 51. Radio modem MR400 (MR300, MR160, MR160P) ......................................................................... 62. Description of Radiomodem Functions ........................................................................................... 7

    2.1. Radio part ............................................................................................................................. 72.2. Modem part .......................................................................................................................... 72.3. Supplying .............................................................................................................................. 72.4. Radio Modem Assembly ...................................................................................................... 7

    3. Connectors ...................................................................................................................................... 93.1. Antenna ................................................................................................................................ 93.2. Serial Interface ..................................................................................................................... 93.3. Ethernet .............................................................................................................................. 113.4. Analog and Digital Inputs and Outputs ............................................................................... 123.5. Supply Connector ............................................................................................................... 143.6. Information LED ................................................................................................................. 143.7. Service Connector .............................................................................................................. 153.8. View of Radio Modem ........................................................................................................ 16

    4. Table of Technical Parameters ...................................................................................................... 175. Dimensional Diagram and Labeling Modems ............................................................................... 196. Modem installation ........................................................................................................................ 21

    6.1. General description of installation ...................................................................................... 216.2. Antenna installation ............................................................................................................ 216.3. Power supply ...................................................................................................................... 226.4. Technology connection ....................................................................................................... 226.5. Mechanical mounting ......................................................................................................... 22

    7. Conditions for MR400 Operation ................................................................................................... 247.1. Important Warning .............................................................................................................. 247.2. Conditions of Liability for Defects and Instructions for Safe Operation of Equipment. ....... 247.3. RoHS and WEEE compliance ............................................................................................ 257.4. EU Declaration of Conformity ............................................................................................. 267.5. Country of Origin ................................................................................................................ 277.6. Limitations of Use ............................................................................................................... 28

    A. Revision History ............................................................................................................................ 29

    List of Figures1. Radio modem MR400 with Cannon connectors, MR300 with Cannon connectors and MR160with screw clamps ............................................................................................................................... 53.1. RS232 DSUB9 female .................................................................................................................. 93.2. Data cable RS485 connections .................................................................................................. 103.3. Labelling of serial interface terminals ......................................................................................... 113.4. RJ-45F ........................................................................................................................................ 123.5. Wiring diagrams for analog and digital inputs and outputs ........................................................ 123.6. Description of analog and digital inputs and outputs .................................................................. 133.7. Examples of wiring analog inputs and outputs ........................................................................... 133.8. Power connector & information LED .......................................................................................... 143.9. Service connector ....................................................................................................................... 153.10. Service cable connector connections ....................................................................................... 153.11. View of radio modem description of connectors, model with DSUB (Canon) connectorsand with terminals, numbering of slots .............................................................................................. 165.1. Mounting dimensions of the radiomodem MR400, MR300 and MR160 .................................... 19

    3 RACOM s.r.o. Narrowband modems PROFI MR400, MR300, MR160

  • 6.1. Example of a typical installation of a data network radio point ................................................... 216.2. Example of the layout of equipment in a switchboard ................................................................ 237.1. Warning sticker IEC 60417-5041 (DB:2002-10) ......................................................................... 257.2. EU Declaration of Conformity ..................................................................................................... 267.3. Country of Origin declaration ..................................................................................................... 27

    List of Tables3.1. Table of data connector RS232 connections ................................................................................ 93.2. Table of data connector RS422 connections .............................................................................. 103.3. Table for distinguishing LEDs for RxD and TxD by colour ......................................................... 103.4. Table of Ethernet to cable connector connections ..................................................................... 123.5. Table of digital and analog input and output parameters ........................................................... 133.6. Table of service connector connections ..................................................................................... 153.7. Slot options ................................................................................................................................. 164.1. Table of technical parameters MR400, MR300, MR160 ............................................................ 174.2. Standards complied .................................................................................................................... 184.3. Railway Safety Appliance Standards Regulations ..................................................................... 18

    Narrowband modems PROFI MR400, MR300, MR160 RACOM s.r.o.4

    Narrowband modems PROFIMR400, MR300, MR160

  • IntroductionThis operator manual serves as the primary document for familiarising users with the parameters ofthe radio modem, its properties, modifications and with the parameters of connecting parts. In order tomaster all the functions of the radio modem and theMORSE system you should refer to other documents.

    In next description is used the notation modem or router instead of radiomodem.

    Fig. 1: Radio modem MR400 with Cannon connectors, MR300 with Cannon connectors and MR160with screw clamps

    5 RACOM s.r.o. Narrowband modems PROFI MR400, MR300, MR160

    Introduction

  • 1. Radio modem MR400 (MR300, MR160, MR160P)MR 400, MR300and MR160 are conceptually new radio modems designed for transmitting data in theVHF and UHF bands. The radio modem uses 4-state FSKmodulation providing for a maximum signallingrate of 21.68 kbit/s.

    The radio modem is of modular design with one to four standard RS232 ports (an RS422 or RS485port can be used in place of two of them) available to the user. The configuration can be extended byan Ethernet interface and also by a module with analog and digital inputs/outputs. It is generally man-ufactured with two analog inputs an