16
SS-MXS www.daikincomfort.com 11/15 Supersedes 4/15 MXS Series Product Features • Inverter Compressor • 208/230/1 Power Supply Cooling Operang Range: 0° - 115° F (w/ Wind Baffle) Heang Operang Range: -4° - 75° F (w/ Drain Pan Heater) • Precharged for up to 131 ſt of Liquid Line • Outdoor Sound Pressures as Low as 50 dB(A) Outdoor Unit Quiet Operaon Auto Changeover Auto Fan Speed Control Self Diagnoscs with Digital Display Auto Restart aſter Power Failure An-Corrosion Treatment on Heat Exchanger High-Efficiency Multi-Zone Ductless System Up to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registraon must be completed within 60 days of installaon. Online registraon and some of the addional requirements are not required in California or Quebec.

MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

SS-MXS www.daikincomfort.com 11/15Supersedes 4/15

MXS Series

Product Features• Inverter Compressor• 208/230/1 Power Supply• Cooling Operating Range:

0° - 115° F (w/ Wind Baffle)• Heating Operating Range:

-4° - 75° F (w/ Drain Pan Heater)• Precharged for up to 131

ft of Liquid Line• Outdoor Sound Pressures

as Low as 50 dB(A)

• Outdoor Unit Quiet Operation• Auto Changeover• Auto Fan Speed Control• Self Diagnostics with Digital Display• Auto Restart after Power Failure• Anti-Corrosion Treatment

on Heat Exchanger

High-Efficiency Multi-Zone Ductless System

Up to 19.9 SEER Up to 12.7 EER

Up to 12.5 HSPF

* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration and some of the additional requirements are not required in California or Quebec.

Page 2: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

2 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 3

Product Specifications

Outdoor Units

Model Name 2MXS18NMVJU 3MXS24NMVJU 4MXS36NMVJU RMXS48LVJU

Cooling Capacity (Rated - Max) BTU/h 18,000-21,000 24,000-30,000 36,000-38,000 48,000

Heating Capacity (Rated - Max) BTU/h 18,900-25,000 24,000-36,000 36,000-43,000 54,000

Max Connected Capacity BTU/h 24,000 39,000 48,000 62,400

Min-Max No. of Indoor Units Connections 2 2-3 2-4 2 – 8

Sound Pressure (Cooling/Heating) dB(A) 50/51 52/54 52/54 57/58

Operating Range - Cooling °F DB 14 - 115 14 - 115 14 - 115 14 - 115

Operating Range - Heating 5 – 75 5 – 75 5 – 75 5 – 75

Operating Range - Heating with Drain Pan Heater

°F DB -4 – 75 -4 – 75 -4 – 75 -4 – 75

Piping Dimensions

Max. Length (for all rooms) ft. 164 230 230 433

Max. Length (for one room) ft. 82 82 82 82

Max. Piping Height ft. 49.2 49.2 49.2 98.4

Electrical Data

Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60

Minimum Circuit Amps A 15.8 18.7 19.8 27

Max. Overcurrent Protection A 20 20 20 30

Dimensions (H x W x D) in. 29 x 34¼ x 12⅝ ` 29 x 34¼ x 12⅝ 29 x 34¼ x 12⅝ 52¹⁵⁄₁₆ x 35⁷⁄₁₆ x 12⅝

Net Weight lbs. 128 132 137 129

SEER/ EER

Non-Ducted 18.9/ 12.5 17.9/ 12.7 17.7/ 9.2 18.8/ 10.3

Mixed 16.5/ 11.0 15.9/ 11.2 15.9/ 8.5 16.5/ 9.8

Ducted 14.0/ 9.5 14.0/ 9.7 14.0/ 7.9 14.1/ 9.3

HSPF/ COP

Non-Ducted 10.7 /4.1 12.5/ 4.6 12.2/ 4.5 11.3/ 3.0

Mixed 9.5/ 4.1 10.4/ 3.2 10.2/ 3.4 16.5/ 2.9

Ducted 8.2/ 4.1 8.2/ 3.9 8.2/ 3.9 14.1/ 2.7

Indoor Wall-Mounted Units

Model Name CTXS07LVJU FTXS09LVJU FTXS12LVJU FTXS15LVJU FTXS18LVJU FTXS24LVJU

Outdoor Unit Compatibility

2MXS18NMVJU 2MXS18NMVJU 2MXS18NMVJU 2MXS18NMVJU 3MXS24NMVJU

3MXS24NMVJU 3MXS24NMVJU 3MXS24NMVJU 3MXS24NMVJU 4MXS36NMVJU 4MXS36NMVJU

4MXS36NMVJU 4MXS36NMVJU 4MXS36NMVJU 4MXS36NMVJU RMXS48LVJU RMXS48LVJU

RMXS48LVJU RMXS48LVJU RMXS48LVJU RMXS48LVJU

Airflow-Wet (H/M/L/SL) CFM332/261/ 194/145

381/279/ 194/145

403/307/ 205/155

568/477/ 385/360

583/484/ 385/360

643/494/ 350/328

Airflow-Dry (H/M/L/SL) CFM350/290/ 233/219

420/321/ 233/219

438/335/ 240/212

593/505/ 417/371

625/526/ 431/399

699/572/ 445/403

Sound Pressure - Cooling (H/M/L/SL) dB(A) 38/32/25/22 41/33/25/22 45/37/29/23 45/40/35/32 46/41/36/33 51/44/37/34

Sound Pressure - Heating (H/M/L/SL) dB(A) 38/33/28/25 42/35/28/25 45/39/29/26 43/38/33/30 45/40/35/32 48/42/37/34

Piping Connections

Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4

Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 5/8

Condensate Drain in. Ø 5/8 Ø 5/8 Ø 5/8 Ø 5/8 Ø 5/8 Ø 5/8

Dimensions (H x W x D) in. 11⅝ x 31½ x 8⁷⁄₁₆ 13⅜ x 41⅝ x 9¾

Net Weight lbs. 20 20 22 31 31 31

Page 3: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

2 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 3

Product Specifications

Indoor Slim-Duct UnitsModel Name FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU

Outdoor Unit Compatibility

2MXS18NMVJU 2MXS18NMVJU 2MXS18NMVJU 3MXS24NMVJU

3MXS24NMVJU 3MXS24NMVJU 3MXS24NMVJU 4MXS36NMVJU 4MXS36NMVJU

4MXS36NMVJU 4MXS36NMVJU 4MXS36NMVJU RMXS48LVJU RMXS48LVJU

RMXS48LVJU RMXS48LVJU RMXS48LVJU

External Static Pressure "W.G. 0.12 0.12 0.16 0.16 0.16

Airflow-Wet (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297

Airflow-Dry (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297

Sound Pressure - Cooling (H/M/L/SL) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31

Sound Pressure - Heating (H/M/L/SL) dB(A) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31

Piping Connections

Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4

Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 1/2

Condensate Drain in. Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32

Dimensions (H x W x D) in. 7⅞ x 27⁹⁄₁₆ x 24⁷⁄₁₆ 7⅞ x 35⁷⁄₁₆ x 24⁷⁄₁₆

Indoor 2’x2’ Ceiling Cassette UnitsModel Name FFQ09LVJU FFQ12LVJU FFQ15LVJU FFQ18LVJU

Outdoor Unit Compatibility

2MXS18NMVJU 2MXS18NMVJU 2MXS18NMVJU 3MXS24NMVJU

3MXS24NMVJU 3MXS24NMVJU 3MXS24NMVJU 4MXS36NMVJU

4MXS36NMVJU 4MXS36NMVJU 4MXS36NMVJU RMXS48LVJU

RMXS48LVJU RMXS48LVJU RMXS48LVJU

Cooling Capacity (Nominal) BTU/h 9,500 12,000 15,000 18,000

Heating Capacity (Nominal) BTU/h 11,100 14,000 17,500 21,000

Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60

Airflow Rate (H/L) CFM 318/230 353/230 424/283 530/353

Sound Pressure - Cooling (H/L) dB(A) 36/29 38/29 42/31 46/37

Sound Pressure - Heating (H/L) dB(A) 36/29 38/29 42/31 46/37

Piping Connections

Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4

Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2

Condensate Drain (O.D.) in. Ø 1-1/32 Ø 1-1/32 Ø 1-1/32 Ø 1-1/32

Dimensions – Unit (H x W x D) in. 11¼ x 22⅝ x 22⅝ 11¼ x 22⅝ x 22⅝

Dimensions – Deco Panel (H x W x D) in. 2¼ x 27⅝ x 27⅝ 2¼ x 27⅝ x 27⅝

Net Weight lbs. 38.5 38.5 38.5 38.5

Indoor Floor-Standing UnitsModel Name FVXS09NVJU FVXS12NVJU FVXS18NVJU

Outdoor Unit Compatibility

2MXS18NMVJU 2MXS18NMVJU 3MXS24NMVJU

3MXS24NMVJU 3MXS24NMVJU 4MXS36NMVJU

4MXS36NMVJU 4MXS36NMVJU RMXS48LVJU

RMXS48LVJU RMXS48LVJU

Airflow Rate Cooling CFM 290 300 378

Airflow Rate Heating CFM 311 332 417

Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60

Sound Pressure - Cooling dB(A) 38/32/26/23 39/33/27/24 44/40/36/32

Sound Pressure - Heating dB(A) 38/32/26/23 39/33/27/24 44/40/36/32

Piping Connections

Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4

Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2

Dimensions – Unit (H x W x D) in. 23⅝ x 27½ x 8¼

Net Weight lbs. 31 31 31

Page 4: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

4 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 5

Product Specifications

Piping Requirements Allowable Length Details

Maximum allowable length

Between outdoor and BP units Total piping lengthPiping length between outdoor and BP units ≤ 180 ft (55 m) -[Example] a+b+c+d+e ≤ 180 ft

Between BP and indoor units Total piping lengthPiping length between BP and indoor units: 262 ft (80 m) - [Example] f+g+h+i+j+k+l ≤ 262ft

Between BP and indoor unit 1 room lengthPiping length between BP and indoor unit ≤ 49 ft (15 m) - [Example] f, g, h, i, j, k, l ≤ 49 ft

Allowable height

Between outdoor and indoor units

Difference in height

Difference in height between outdoor & indoor units (H1) ≤ 98 ft (30 m)

Between outdoor and BP units Difference in height between outdoor and BP units (H2) ≤ 98 ft (30 m)

Between BP and BP units Difference in height between BP and BP units (H3) ≤ 49 ft (15 m)

Between indoor and indoor units Difference in height between indoor and indoor units (H4) ≤ 49 ft (15 m)

Minimum allowable length Piping lengthPipe length between outdoor unit and first refrigerant branch kit (refnet joint) ≥ 16.4 ft [Example] a ≥ 16.4 ft

Allowable length after the REFNET branch

Piping length from first refrigerant branch kit (REFNET joint) to indoor unit ≤ 131 ft (40 m) [Example] unit 6: b+c+k ≤ 131 ft [Example] unit 5: b+e+j ≤ 131 ft [Example] unit 3: d+h ≤ 131 ft

Additional refrigerant calculationTotal length (ft / m) of liquid pip-ing size at Ø 3/8 inch (Ø 9.5mm)

x +Total length (ft / m) of liquid piping size at Ø 1/4 inch (Ø

6.4mm)

BP UnitsModel Name BPMKS048A2UPower Supply V/Ph/Hz 208-230/1/60Power Consumption W 10Running Current A 0.05Sound Pressure - (Cooling/Heating) dB(A) 32/32Number of Connectable Indoor Units 1 to 2Minimum Connection Combination 7,000Maximum Connection Combination 48,000

Piping Connections (O.D.)Liquid

Outdoor Unit Side in. Ø 1/4 x 2Indoor Unit Side in. Ø 1/4 x 2

GasOutdoor Unit Side in. Ø 5/8 x 2Indoor Unit Side in. Ø 5/8 x 2

Dimensions (H x W x D) in. 7⅟₁₆ x 11⁹⁄₁₆ x 13¾Net Weight lbs. 18

Nominal Conditions:Cooling Mode: Heating Mode: Note:Indoor: 80 °F DB / 67 °F WB Indoor: 70 °F DB Specifications are subject

to change without noticeOutdoor: 95 °F DB Outdoor: 47 °F DB / 43 °F WB

Level Difference: 0 ft. Level Difference: 0 ft.

Page 5: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

4 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 5

Dimensions — Slim-Duct Indoor Units

FDXS09/12LVJU

SIGNAL TRANSMITTER11/16 (18mm)

2-5/16 (58mm)

7-3/8

(187m

m)

PROTECTION NET10AIR FILTER (ACCESSORY)9SUSPENSION BRACKET8POWER SUPPLY CONNECTION7INFRARED RECEIVER UNIT CONNECTION6CONTROL BOX5DRAIN HOSE (ACCESSORY)4 I.D. φ31/32(φ25mm) (OUTLET)SOCKET FOR DRAIN VP20 (O.D. φ1-1/32 (φ26mm)/ I.D. φ25/32 (φ20mm))3GAS PIPE CONNECTION2LIQUID PIPE CONNECTION1 φ1/4 (φ6.4mm) (FLARE CONNECTION)

φ3/8 (φ9.5mm) (FLARE CONNECTION)

NUMBER DESCRIPTIONNAME

12(300mm) OR MORE27-9/16(700mm)(SERVICE SPACE)

24-7/16(1-3/4) (45mm)

(620mm)

15-3/4 (400mm) OR MORE

9-1/2(

240m

m) O

R MO

RE13

/16 (2

0mm)

OR

MORE

(13/16) 1-1/2 (38mm)2-3/4ROOM TEMP.SENSOR

(SU

SPEN

SIO

N B

OLT

PIT

CH

)

(20mm)(70mm)

27-9

/16

(700

mm

)

OPERATION LAMP

24-7

/16(

620m

m)

19-1

1/16

(500

mm

)

TIMER LAMP

4-3/4

(120m

m)

CEILING8INDOOR UNITON/OFF SWITCH

(300

mm

)11

-13/

16 SIGNAL RECEIVER

<< SERVICE SPACE >>16-φ 3/16 (φ4.7mm) 5x(P3-15/16)=19-11/16HOLE

(2-13

/16) (7

2mm)

(P100mm) INFRARED RECEIVER UNIT(ALL AROUND) ARROW VIEW

13/16

(20m

m) O

R MOR

E

2-3/

8 (6

0mm

)

29-1/8 (740mm) INSPECTION DOOR(CEILING OPENING)(SUSPENSION BOLT PITCH) 16-M5 HOLESSUSPENSION BOLT

(ALL AROUND)5-1/8 (130mm) 3-9/16 (90mm) 23-5/8 (600mm)26-3/4 (680mm)2-1/2 (63mm)26 (660mm) 22-13/16 (580mm)3-15/16 (100mm)

13/16

(20m

m)1-

15/16

(50m

m)

4x(P5-7/8)=23-5/8

2-1/4

(57.5m

m)

3/8 (1

0mm)

13/16

(21m

m)1/2

(12.5

mm)

1012(P150mm) (600mm)9

4

71-3/16 (30mm)14-M4 HOLES 5-1/2 (140mm) 5x(P3-15/16)=19-11/16

(ALL AROUND) (P100mm) (500mm)7/8

(23m

m) 3 5

6 (15

3mm) 13 (330mm)

3-1/8

(80mm

)

3-15

/16 (1

00mm

)

24-7/16 (620mm)3-1/8 (80mm)

3-15

/16 (1

00mm

)6-

5/16 (

160m

m)

6-11

/16 (1

70mm

)

7-7/8

(200m

m)6-1

1/16 (

170m

m)

7-1/1

6 (18

0mm)

<< IN CASE OF BACK-SUCTION >>(620mm)24-7/16

(600mm)23-5/8

9

7-1/16

(180

mm)

6-5/16

(160

mm)

3-15/1

6 (10

0mm)

7-7/

8 (2

00m

m)

63-1/8 (80mm)103-9/16 (90mm)

3/8

(10m

m)

5x(P3-15/16)=19-11/16 5-1/2 (140mm)

13/16

(20m

m)1-1

5/16 (

50mm

)

(P100mm) (500mm)3-15/16 (100mm)22-13/16 (580mm)

16-M5 HOLES<< IN CASE OF BOTTOM-SUCTION >>(ALL AROUND)

WIRELESS REMOTE CONTROLLER(ARC452A23)

4-M8~M10

1. IN CASE OF BACK-SUCTION, MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.IN CASE OF BOTTOM-SUCTION, MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.

2. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.

SELECT ITS COLORIMETHOD (GRAVITY METHOD) 50% OR MORE.IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY) WHEN CONNECTING DUCT TO SUCTION SIDE.

4. PIPE SPECIFICATION

NOTE)

)(

CORD (LENGTH: 74-13/16)( : 1900mm)

3-9/1

6 (90

mm)

1-7/8

(47m

m)

(500mm)

3D074619

CDXS15/18LVJU11-13/16 (300mm) OR MORE35-7/16 (900mm) 24-7/16 (620mm)

(SERVICE SPACE)

15-3/4 (400mm) OR MORE (1-3/4) (45mm)

13/16

(20mm

) OR M

ORE

SIGNAL TRANSMITTER11/16 (18mm)

2-5/16 (58mm)

13/1

6 (2

0mm

) OR

MO

RE

(13/16) 1-1/2 (38mm)2-3/4ROOM TEMP.

35-7

/16

(900

mm

)

SENSOR (20mm)(70mm)

24-7

/16

(620

mm

)

19-1

1/16

(500

mm

)

OPERATION LAMP

(SUS

PENS

ION

BOLT

PITC

H)

CEILINGTIMER LAMP

4-3/4

(120m

m)

< SERVICE SPACE >(ALL AROUND) INDOOR UNIT

7-3/

8 (1

87m

m)

22-φ 3/16 (φ 4.7mm) HOLES ON/OFF SWITCH9-1/2 (

240mm

) OR M

ORE

8 8xP.3-15/16 (100mm)=31-1/2 (800mm) SIGNAL RECEIVERCORD (LENGTH: 74-13/16)37 (940mm)

( :1900mm)(SUSPENSION BOLT PITCH) 2-3/8

(60m

m)

(2-1

3/16

) (72

mm

)

INFRARED RECEIVER UNIT WIRELESS REMOTE CONTROLLER34-5/8 (880mm)(ARC452A23)5-1/8 (130mm) 2-1/2 (63mm)33-7/8 (860mm) ARROW VIEW3-9/16 (90mm) 3-9/16 (90mm)4xP.5-7/8 (150mm)=23-5/8 (600mm) INSPECTION DOOR

11-13

/16 (3

00mm

)

(CEILING OPENING)SUSPENSION BOLT 2 14-UNC5/16 ~ 3/8

3-9/

16 (9

0mm

)1-

7/8

(47m

m)

(M8 ~ M10) 20-M5 HOLES

1-15

/16 (5

0mm)

13/16

(20m

m)

2-1/4

(57.5m

m)13

/16 (2

1mm)

3/8

(10m

m)

1/2 (1

2.5mm

)

10(ALL AROUND)

6 (153m

m)

6-5/16

(160m

m)7-1

/16 (18

0mm)

7-7/8 (

200mm

)6-1

1/16 (1

70 mm

)

71-3/16 (30mm)18-M4 HOLES 7xP.3-15/16 (100)=27-9/16 (700mm)5-7/8 (150 mm)13 (330mm)

(ALL AROUND) 53 30-11/16 (780mm)3-15/16 (100 mm)4

7/8

(23m

m)

93-9/16 (90mm) 31-1/2 (800mm)

3-1/8

(80mm

)

3-15

/16

(100

mm

)

3-15

/16

(100

mm

)

32-5/16 (820mm)3-1/8 (80mm)

6-11

/16

(170

mm

)

<IN CASE OF BACK-SUCTION>

20-M5 HOLES PROTECTION NET10(ALL AROUND) AIR FILTER (ACCESSORY)9

SUSPENSION BRACKET8

3-15

/16

(100

mm

)

POWER SUPPLY CONNECTION7INFRARED RECEIVER UNIT CONNECTION6

1. IN CASE OF BACK-SUCTION,NOTE)10 CONTROL BOX5MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.IN CASE OF BOTTOM-SUCTION,

6-5/16

(160m

m)

I.D.φ 31/32 (φ 25mm) (OUTLET)DRAIN HOSE (ACCESSORY)4

7-7/8 (

200mm

)7-1

/16 (18

0mm)

6 MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT. SOCKET FOR DRAIN VP20 O.D.φ 1-1/32 (φ 26mm)32. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER5-1/8 (130mm)7xP.3-15/16 (100mm)=27-9/16 (700mm) 3. MOUNT THE AIR FILTER AT THE SUCTION SIDE. /I.D.φ 25/32 (φ 20mm) )(SELECT ITS COLORIMETHOD (GRAVITY METHOD)30-11/16 (780mm) 3-15/16 (100mm) )(50% OR MORE.

GAS PIPE CONNECTION φ 1/2 (φ 12.7mm) (FLARE CONNECTION)231-1/2 (800mm) 3-9/16 (90mm)9

3/8

(10m

m)

IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY)32-5/16 (820mm) 3-1/8 (80mm)

13/1

6 (2

0mm

)

LIQUID PIPE CONNECTION1 φ 1/4 (φ 6.4mm) (FLARE CONNECTION)WHEN CONNECTING DUCT TO SUCTION SIDE.1-1

5/16 (

50mm

)

< IN CASE OF BOTTOM-SUCTION > NAME DESCRIPTIONNUMBER

(IN CASE OF BOTTOM SUCTION)

3D075268

Page 6: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

6 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 7

Dimensions — Slim-Duct Indoor Units

CDXS15/18LVJU11-13/16 (300mm) OR MORE35-7/16 (900mm) 24-7/16 (620mm)

(SERVICE SPACE)

15-3/4 (400mm) OR MORE (1-3/4) (45mm)

13/16

(20mm

) OR M

ORE

SIGNAL TRANSMITTER11/16 (18mm)

2-5/16 (58mm)

13/1

6 (2

0mm

) OR

MO

RE

(13/16) 1-1/2 (38mm)2-3/4ROOM TEMP.

35-7

/16

(900

mm

)

SENSOR (20mm)(70mm)

24-7

/16

(620

mm

)

19-1

1/16

(500

mm

)

OPERATION LAMP

(SUS

PENS

ION

BOLT

PITC

H)

CEILINGTIMER LAMP

4-3/4

(120m

m)

< SERVICE SPACE >(ALL AROUND) INDOOR UNIT

7-3/

8 (1

87m

m)

22-φ 3/16 (φ 4.7mm) HOLES ON/OFF SWITCH9-1/2 (

240mm

) OR M

ORE

8 8xP.3-15/16 (100mm)=31-1/2 (800mm) SIGNAL RECEIVERCORD (LENGTH: 74-13/16)37 (940mm)

( :1900mm)(SUSPENSION BOLT PITCH) 2-3/8

(60m

m)

(2-1

3/16

) (72

mm

)

INFRARED RECEIVER UNIT WIRELESS REMOTE CONTROLLER34-5/8 (880mm)(ARC452A23)5-1/8 (130mm) 2-1/2 (63mm)33-7/8 (860mm) ARROW VIEW3-9/16 (90mm) 3-9/16 (90mm)4xP.5-7/8 (150mm)=23-5/8 (600mm) INSPECTION DOOR

11-13

/16 (3

00mm

)

(CEILING OPENING)SUSPENSION BOLT 2 14-UNC5/16 ~ 3/8

3-9/

16 (9

0mm

)1-

7/8

(47m

m)

(M8 ~ M10) 20-M5 HOLES

1-15

/16 (5

0mm)

13/16

(20m

m)

2-1/4

(57.5m

m)13

/16 (2

1mm)

3/8

(10m

m)

1/2 (1

2.5mm

)

10(ALL AROUND)

6 (153m

m)

6-5/16

(160m

m)7-1

/16 (18

0mm)

7-7/8 (

200mm

)6-1

1/16 (1

70 mm

)

71-3/16 (30mm)18-M4 HOLES 7xP.3-15/16 (100)=27-9/16 (700mm)5-7/8 (150 mm)13 (330mm)

(ALL AROUND) 53 30-11/16 (780mm)3-15/16 (100 mm)47/

8 (2

3mm

)93-9/16 (90mm) 31-1/2 (800mm)

3-1/8

(80mm

)

3-15

/16

(100

mm

)

3-15

/16

(100

mm

)

32-5/16 (820mm)3-1/8 (80mm)

6-11

/16

(170

mm

)

<IN CASE OF BACK-SUCTION>

20-M5 HOLES PROTECTION NET10(ALL AROUND) AIR FILTER (ACCESSORY)9

SUSPENSION BRACKET8

3-15

/16

(100

mm

)

POWER SUPPLY CONNECTION7INFRARED RECEIVER UNIT CONNECTION6

1. IN CASE OF BACK-SUCTION,NOTE)10 CONTROL BOX5MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.IN CASE OF BOTTOM-SUCTION,

6-5/16

(160m

m)

I.D.φ 31/32 (φ 25mm) (OUTLET)DRAIN HOSE (ACCESSORY)4

7-7/8 (

200mm

)7-1

/16 (18

0mm)

6 MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT. SOCKET FOR DRAIN VP20 O.D.φ 1-1/32 (φ 26mm)32. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER5-1/8 (130mm)7xP.3-15/16 (100mm)=27-9/16 (700mm) 3. MOUNT THE AIR FILTER AT THE SUCTION SIDE. /I.D.φ 25/32 (φ 20mm) )(SELECT ITS COLORIMETHOD (GRAVITY METHOD)30-11/16 (780mm) 3-15/16 (100mm) )(50% OR MORE.

GAS PIPE CONNECTION φ 1/2 (φ 12.7mm) (FLARE CONNECTION)231-1/2 (800mm) 3-9/16 (90mm)9

3/8

(10m

m)

IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY)32-5/16 (820mm) 3-1/8 (80mm)

13/1

6 (2

0mm

)

LIQUID PIPE CONNECTION1 φ 1/4 (φ 6.4mm) (FLARE CONNECTION)WHEN CONNECTING DUCT TO SUCTION SIDE.1-1

5/16 (

50mm

)

< IN CASE OF BOTTOM-SUCTION > NAME DESCRIPTIONNUMBER

(IN CASE OF BOTTOM SUCTION)

3D075268

CDXS24LVJU

43-5/16 24-7/16

8

24-7

/16

7-7/

8

3-1/

82-

1/4

6-11

/16

1/2

613

/16

7-7/

8

1-15

/16

3-15/1

6

3/8

7-1/

1613

/16

6-5/

16

2-3/

8

13/16

OR

MORE

9-7/16

OR MO

RE

13/16

OR

MORE

10× (P3-15/16)=39-3/8

(ALL AROUND) 26-φ3/16 HOLE

44-7/8(SUSPENSION BOLT PITCH)

11-13/16 OR MORE(SERVICE SPACE)

19-1

1/16

( SUS

PENS

ION

BOLT

PITC

H)

SIGNAL TRANSMITTER

SUSPENSION BOLT 4-M8~M10

18-M4 HOLES (ALL AROUND)

42-1/2

1-3/16

41-3/46×P5-7/8=35-7/16

4

2

3 5

7

10

9

1

10

6

95-1/89× (P3-15/16)=35-7/16

38-9/1639-3/840-3/16

3-15/163-9/163-1/8

IN CASE OF BOTTOM-SUCTION

24-M5 HOLES (ALL AROUND)

NOTE)1. IN CASE OF BACK-SUCTION, MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.IN CASE OF BOTTOM-SUCTION, MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.

2. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.

SELECT ITS COLORIMETHOD (GRAVITY METHOD) 50% OR MORE.IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY)WHEN CONNECTING DUCT TO SUCTION SIDE.

( )I.D. φ31/32 (OUTLET)VP20 (O.D. φ1-1/32/I.D. φ25/32)φ5/8 (FLARE CONNECTION)φ1/4 (FLARE CONNECTION)

DESCRIPTION

SERVICE SPACE

10987654321

NUMBER

PROTECTION NETAIR FILTER (STANDARD ACCESSORY)SUSPENSION BRACKETPOWER SUPPLY CONNECTIONINFRARED RECEIVER UNIT CONNECTIONCONTROL BOXDRAIN HOSE (STANDARD ACCESSORY)SOCKET FOR DRAINGAS PIPE CONNECTIONLIQUID PIPE CONNECTION

NAME

CEILING

15-3/4 OR MORE(IN CASE OF BOTTOM SUCTION)

43-5

/16

4-3/

4

7-3/

8

( 2-1

3/16

)

11-13

/16

ARROW VIEWINSPECTION DOOR (CEILING OPENING)

INFRARED RECEIVER UNIT WIRELESS REMOTE CONTROLLER (ARC452A23)

24-M5 HOLES(ALL AROUND)

TIMER LAMP

OPERATION LAMP

INDOOR UNIT ON/OFF SWITCH

ROOM TEMP. SENSOR

SIGNAL RECEIVER CORD (LENGTH: 74-13/16)

2-3/4 1-1/2 11/162-5/16

(13/16)

(1-3/4)

5-1/8

13

2-1/2

5-7/8 9× (P3-15/16)=35-7/1638-9/1639-3/8

40-3/16

3-15/163-9/163-1/8

1-7/

83-

9/16

6-11

/16

3-15/1

67/

8

1-15

/16

3-15/1

613

/16

6-5/

163/

87-

1/16

IN CASE OF BACK-SUCTION

3D080591

Page 7: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

6 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 7

Dimensions — Wall-Mount Indoor Unit

CTXS07LVJU, FTXS09/12LVJU

FRONT GRILLEFIXED SCREWS(INSIDE)

FLAPS

WIRELESS REMOTE CONTROLLER(ARC452A21)

(SPA

CE

FOR

PER

FOR

MAN

CE)

(SPACE FORMAINTENANCE) (SPACE FOR MAINTENANCE)

INTELLIGENT EYE SENSORSIGNAL RECEIVEROPERATION LAMP DRAIN HOSE

(CONNECTING PARTO.D. φ5/8 (φ16mm)THE HOSE LENGTH OF OUTSIDETHE UNIT IS APPROX. 18-5/16 (465mm))

GAS PIPE φ3/8 (φ9.5mm) CuT(THE LENGTH OF PIPE OUTSIDETHE UNIT: ABOUT 13-3/4 (350mm))TIMER LAMP

INTELLIGENT EYE LAMP LIQUID PIPE φ1/4 (φ6.4mm) CuT(THE LENGTH OF PIPE OUTSIDETHE UNIT: ABOUT 15-3/4 (400mm))

SIGNAL TRANSMITTER

STANDARD LOCATIONS OF WALL HOLES

AIRFLOW (INDOOR)

INCLUDINGMOUNTING PLATE )(

REQUIRED SPACE

NAME PLATE

TERMINAL BLOCKWITH GROUNDTERMINAL

INDOOR UNIT ON/OFF SWITCH

ROOM TEMP. THERMISTOR (INSIDE)MODEL NAME PLATE

BLADE ANGLESUP/DOWN(AUTOMATIC)

WALL HOLEφ2-9/16 (φ65mm) HOLEWALL HOLE FOR

EMBEDDED PIPINGφ2-9/16 (φ65mm) HOLE

31-1/2 (800mm)

REAR

RIGHTLEFT

1-3/

16 (3

0mm

) MIN

8-9/16 (217mm)

1-15/16 (50mm) MIN8-7/16 (215mm)1-15/16 (50mm) MIN

11-5

/8 (2

95m

m)

BOTTOM

31-1/2 (800mm)23-1/16 (586mm)

9/16

(14.

5mm

)

5-3/4 (145.5mm)2-5/16 (58mm) 11/16 (18mm)

FANCOOLING, DRY HEATING

5°15°

1-3/

4 (4

4.5m

m)

1-3/

4 (4

4.5m

m)

11-5

/8 (2

95m

m)

30°35° 30°30°

7-3/

8 (1

87m

m)

65°55° 65°45° 70° 80°

2-3/8 (60mm) 2-5/16 (59.5mm)RIGHT/LEFT(AUTOMATIC)

45° 45°

THE MARK (→) SHOWS PIPING DIRECTION

C: 3D074094A

FTXS15/18LVJU

DRAIN HOSE(CONNECTING PARTO.D. φ5/8 (φ16mm)THE HOSE LENGTH OF OUTSIDETHE UNIT: ABOUT 18-5/16 (465mm))

SIGNALTRANSMITTER

11/16 (18mm)2-5/16 (58mm) UP/DOWN(AUTOMATIC)

FANCOOLING, DRY HEATING

15°15°

25° 30°

7-3/

8 (1

87m

m)

25°40° 75°50° 60° 75° 70°70°

WIRELESS REMOTE CONTROLLER(ARC452A21)

41-5/16 (1050mm)

9-13/16 (250mm)9-3/4 (248mm)

MIN.1-15/16 (50mm) MIN.1-15/16 (50mm)

13-3

/8 (3

40m

m)

41-5/16 (1050mm)

9/16 (

14.5m

m)

1-3/8 (35.5mm)37-5/16 (947mm)

5/8

(16m

m)

8-1/4

(210

mm)

13-3

/8 (3

40m

m)

1-3/

4 (4

5mm

)

3-1/2 (89mm)2-9/16 (65mm)

1-3/

4 (4

5mm

)

45° 45°

THE MARK ( → )SHOWS PIPING DIRECTION AIRFLOW (INDOOR)

REARLEFT RIGHTINCLUDING

INSTALLATION PLATE

(SPACE FORMAINTENANCE)

(SPACE FORMAINTENANCE) REQUIRED SPACENAME PLATE

INTELLIGENT EYE SENSORBOTTOMSIGNAL RECEIVERFLAPS OPERATION LAMP

TIMER LAMPINTELLIGENT EYE LAMPINDOOR UNIT ON/OFFSWITCH

MODEL NAME PLATEBLADE ANGLES

RIGHT/LEFT (AUTOMATIC)

MIN

.1-3

/16

(30m

m)

(SPA

CE

FOR

PER

FOR

MAN

CE)

FRONTGRILLEFIXINGSCREWS(INSIDE)

TERMINAL BLOCK WITHGROUND TERMINAL(INSIDE)

GAS PIPE φ1/2 (φ12.7mm) CuT(THE LENGTH OF PIPE OUTSIDE

THE UNIT: ABOUT 15-3/4 (400mm))LIQUID PIPE φ1/4 (φ6.4mm) CuT

(THE LENGTH OF PIPE OUTSIDETHE UNIT: ABOUT 18-1/8 (460mm))

ROOM TEMP. THERMISTOR(INSIDE)

WALL HOLEφ3-1/8 (φ80mm) HOLE

WALL HOLE FOR EMBEDDEDPIPING φ3-1/8 (φ80mm) HOLE

STANDARD LOCATIONS OF WALL HOLES

( )

C: 3D074024A

Page 8: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

8 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 9

Dimensions — Wall-Mount / Floor-Standing Indoor Units

FTXS24LVJU

SIGNALTRANSMITTER

2-5/16 (58mm) 11/16 (18mm)UP/DOWN(AUTOMATIC)

FANCOOLING, DRY HEATING

15˚ 15˚

25˚ 30˚

7-3/

8 (1

87m

m)

25˚40˚ 75˚50˚ 60˚ 75˚70˚70˚

41-5/16 (1050mm)

9-13/16 (250mm)9-3/4 (248mm)

13-3

/8 (3

40m

m)

41-5/16 (1050mm)

9/16

(14.

5mm

)

1-3/8 (35.5mm)37-5/16 (947mm)

5/8

(16m

m)

8-1/4

(210

mm)

13-3

/8 (3

40m

m)

1-3/

4 (4

5mm

)

3-1/2 (89mm)2-9/16 (65mm)

1-3/

4 (4

5mm

)

45˚ 45˚

THE MARK ( → ) SHOWS PIPING DIRECTION AIRFLOW (INDOOR)

REARLEFT RIGHT

REQUIRED SPACENAME PLATE

INTELLIGENT EYE SENSORBOTTOM

SIGNAL RECEIVERFLAPS OPERATION LAMPTIMER LAMPINTELLIGENT EYE LAMPINDOOR UNIT ON/OFFSWITCH

MODEL NAME PLATEBLADE ANGLES

RIGHT/LEFT (AUTOMATIC)

ROOM TEMP. THERMISTOR(INSIDE)

WALL HOLEφ3-1/8 (φ80mm) HOLE

WALL HOLE FOR EMBEDDEDPIPING φ3-1/8 (φ80mm) HOLE

STANDARD LOCATIONS OF WALL HOLES

FRONT GRILLE FIXING SCREWS (INSIDE)

WIRELESS REMOTE CONTROLLER (ARC452A21)

DRAIN HOSE(CONNECTING PART O.D. φ5/8 (φ16mm)THE HOSE LENGTH OF OUTSIDETHE UNIT: ABOUT 18-5/16 (465mm))

GAS PIPE φ5/8 (φ15.9mm) CuT(THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 15-3/4 (400mm))

LIQUID PIPE φ1/4 (φ6.4mm) CuT(THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 18-1/8 (460mm))

MIN. 1-15/16 (50mm)(SPACE FORMAINTENANCE)

MIN. 1-15/16 (50mm)(SPACE FORMAINTENANCE)

MIN

. 1-3

/16

(30m

m)

(SPA

CE

FOR

PE

RFO

RM

ANC

E)

TERMINAL BLOCK WITH GROUND TERMINAL (INSIDE)

)( INCLUDING INSTALLATION PLATE

C: 3D073962A

FVXS09/12NVJU

27-9/16 (700mm)

OPERATION LAMPTIMER LAMP 8-1/4 (210mm) ROOM TEMP. THERMISTORSIGNAL RECEIVER 3-3/4 (95mm)

(HALF CONCEALED)INDOOR UNIT ON/OFF SWITCH25-3/8 (644mm)LIQUID PIPE (φ1/4 (φ6.4mm CuT))MAIN UNIT FIXING SCREWGAS PIPE (φ3/8 (φ9.5mm CuT))

NAME PLATE

9-13/1

6 (25

0mm)

8-5/

8 (2

18.5

mm

)10

-1/4

(261

mm

)23

-5/8

(600

mm

)

2-3/

4 (7

0mm

)

23 (5

84m

m)

4-3/

4 (1

20.5

mm

)3-

9/16

(90m

m)

3-9/

16 (9

0mm

)

15-3

/4 (4

00m

m)

14-9

/16

(370

mm

)9-1

/16 (2

30mm

)

4-3/

4 (1

20.5

mm

)

11/16 (17mm)FIXED SCREWS FOR FRONT PANEL11/16 (17mm) 3-1/4 (82mm)DRAIN HOSE HOLE FOR SPLINTHOLE FOR SPLINT 4-3/4 (121mm)24-13/16 (630mm) HOLE FOR PIPINGHOLE FOR PIPING

5-3/8 (136mm)FIXED SCREWS FOR MAIN UNIT3-1/4 (82mm)

6-5/16

(160

mm)

5-7/8

(149m

m)

6 (152mm)

3-3/

8 (8

5mm

)

UP/DOWN (AUTOMATIC)RIGHT/LEFT (MANUAL)1-1/2 (38.5mm) COOL, DRY HEAT1-3/4 (44mm) UPPER AIR OUTLET

2-3/4 (70mm)4-1/2 (115mm) 1-1/2 (38.5mm)26-3/8 (670mm)~27-3/16 (690mm)AIR FLOW 40

˚

(WALL HOLE) 25˚

SIGNAL TRANSMITTERREQUIRED SPACE

90˚

90˚

45˚7/8 (21.5mm)2-5/16 (58.5mm) 45˚

LOWER AIR OUTLET

20˚

20˚

2-3/

4 (7

0mm

)

90˚

90˚

45˚

7-7/

16 (1

89m

m)

45˚

ADJUSTING THE AIR FLOW DIRECTION

UPWARD AIR FLOW LIMIT [OFF]

UPWARD AIR FLOW LIMIT [ON]

TERMINAL BLOCK WITH GROUND TERMINAL

(HAL

F C

ON

CEA

LED

)

VP20 I.D. φ13/16 (φ20mm) O.D. φ1 (φ26mm) L8-11/16 (220mm)

DRAIN SOCKET

AIR OUTLET SELECTION SWITCH (INSIDE)

↑→

26-1/4 (666mm) (HALF CONCEALED)

MODEL NAME LABEL

FIXED SCREWS FOR FRONT PANEL (INSIDE)

↑←

↓ ↓

HOLE FOR PIPING

(FOR

PERF

ORMA

NCE)

ARC466A21 WIRELESS REMOTE CONTROLLER

1-15/16 (50mm) MIN

(FOR MAINTENANCE AND PERFORMANCE)

(FOR MAINTENANCE AND PERFORMANCE)

1-15/16 (50mm) MIN23

-1/16

(585

mm)~2

3-7/16

(595

mm)

(WAL

L H

OLE

)

WALL HOLE FOR HALF CONCEALED

NOTE) 1. THE MARK (→) SHOWS PIPING DIRECTION

C: 3D091758

Page 9: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

8 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 9

Dimensions — Floor-Standing Indoor Units

FVXS18NVJU

27-9/16 (700mm)

→→

→←OPERATION LAMPTIMER LAMP 8-1/4 (210mm) ROOM TEMP. THERMISTORSIGNAL RECEIVER 3-3/4 (95mm)

(HALF CONCEALED)INDOOR UNIT ON/OFF SWITCH25-3/8 (644mm) LIQUID PIPE (φ1/4 (φ6.4mm CuT))

MAIN UNIT FIXING SCREW GAS PIPE (φ1/2 (φ12.7mm CuT))

NAME PLATE

9-13

/16

( 250

mm

)

8-5/

8 ( 2

18.5

mm

)10

-1/4

( 261

mm

)23

-5/8

( 600

mm

)

2-3/

4 ( 7

0mm

)

23 ( 5

84m

m)

4-3/

4 ( 1

20.5

mm

)3-

9/16

( 90m

m)

3-9/

16 ( 9

0mm

)

15-3

/4 ( 4

00m

m)

14-9

/16

( 370

mm

)9-1

/16 ( 2

30mm

)

4-3/

4 ( 1

20.5

mm

)

11/16 (17mm)FIXED SCREWS FOR FRONT PANEL11/16 (17mm)

3-1/4 (82mm)DRAIN HOSE HOLE FOR SPLINTHOLE FOR SPLINT 4-3/4 (121mm)24-13/16 (630mm) HOLE FOR PIPINGHOLE FOR PIPING5-3/8 (136mm)FIXED SCREWS FOR MAIN UNIT3-1/4 (82mm)

6-5/16

( 160

mm)

5-7/8

( 149m

m)

6 (152mm)3-

3/8

( 85m

m)

UP/DOWN (AUTOMATIC)RIGHT/LEFT (MANUAL)1-1/2 (38.5mm) COOL, DRY HEAT1-3/4 (44mm) UPPER AIR OUTLET

2-3/4 (70mm)4-1/2 (115mm) 1-1/2 (38.5mm)26-3/8 (670mm)~27-3/16 (690mm)AIR FLOW 40

˚

(WALL HOLE) 25˚

SIGNAL TRANSMITTERREQUIRED SPACE

90˚

90˚

45˚2-5/16 (58.5mm) 7/8 (21.5mm) 45˚

LOWER AIR OUTLET

20˚

20˚

2-3/4

( 70mm

)

90˚

90˚( FOR

PERF

ORMA

NCE)

45˚

7-7/

16 ( 1

89m

m)

45˚

ADJUSTING THE AIR FLOW DIRECTIONWALL HOLE FOR HALF CONCEALED

NOTE) 1. THE MARK (→) SHOWS PIPING DIRECTION

FIXED SCREWS FOR FRONT PANEL (INSIDE)

MODEL NAME LABEL

26-1/4 (666mm) (HALF CONCEALED)

AIR OUTLET SELECTION SWITCH (INSIDE)

TERMINAL BLOCK WITH GROUND TERMINAL

(HAL

F C

ON

CEA

LED

)

VP20 I.D. φ13/16 (φ20mm) O.D. φ1 (φ26mm) L8-11/16 (220mm)

DRAIN SOCKET

↓ ↓

HOLE FOR PIPING

23-1/

16 ( 5

85mm

) ~23-7

/16 ( 5

95mm

)( W

ALL

HO

LE)

1-15/16 (50mm) MIN(FOR MAINTENANCE AND PERFORMANCE)

1-15/16 (50mm) MIN

(FOR MAINTENANCE AND PERFORMANCE)

UPWARD AIR FLOW LIMIT [OFF]

UPWARD AIR FLOW LIMIT [ON]

ARC466A21 WIRELESS REMOTE CONTROLLER C: 3D091774

Page 10: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

10 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 11

Wiring Diagrams — Indoor Units

CTXS07LVJU, FTXS09/12LVJU

1

X1MPCB1PCB3 S46S49 2H1BLK 11 BLK 1 3

~BLK3.15A WHT

OUTDOOR2BLK

C102 V1BLK RED 3- H2MR10BLKGRNBLK

FIELD WIRING.BLKC101BLK

H399 BLK

FGSW1 S21

t˚S1HA 7 REDBZ

4 BLUS25BRNBLK1 1PCB4ORGBLKS26 BLK 1 WHT

S41S47 S3244 BLK M1F1216 22 3 1 116 3131 4 15 9 114 5 78 10

BLK

BLK

BLK

BLK

BLK

PNK

PNK

PNK

BLU

BLU

BLU

OR

G

OR

G

OR

G

RED

RED

RED

YLW

YLW

YLW

S48PCB2t˚1 3

INDOORR2T MSW MSWMSW

M3SM2SM1S

LED1 H1P

LED2 H2P

LED3 H3P

RTH1 R1T

INTELLIGENT EYE SENSOR

WIRELESS REMOTE

CONTROLLER SIGNAL RECEIVER

TRANSMISSION CIRCUIT

FU1 F1U

MS 3~

GRN/YLW

CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN.

BZC101, C102FGF1UH1P~H3PMR10M1FM1S~M3SPCB1~PCB4R1T, R2TS1~S49SW1V1X1M

: BUZZER: CAPACITOR: FRAME GROUND: FUSE: PILOT LAMP: MAGNETIC RELAY: FAN MOTOR: SWING MOTOR: PRINTED CIRCUIT BOARD: THERMISTOR: CONNECTOR: OPERATION SWITCH: VARISTOR: TERMINAL STRIP: PROTECTIVE GROUND

C: 3D058246L

FTXS15/18/24LVJU

1

FU1 X1MPCB1PCB3 S46S49 2H1F1UBLK 11 BLK 1LED1 3BLK

3.15AH1P WHTOUTDOOR

2BLKC102 V1BLKLED2 RED 3--

~

+ H2MR10BLKGRNH2P BLK

FIELD WIRING.BLKLED3GRNC101BLK /H3 YLWH3P 9 9BLK

FGSW1 S21

t˚S1HA 7 RED

RTH1BZR1T

4 BLUS25BLK BRN1 1PCB4BLK ORGS36

1 WHT3S41S47 S32

BLK4 M1F1 1 96 78 1416 4 223 101 2 15 135 11 13

BLK

BLK

BLK

BLK

BLK

PNK

PNK

PNK

BLU

BLU

BLU

ORG

ORG

ORG

RED

RED RE

D

YLW

YLW

YLW

S48PCB2t˚1 3

INDOORR2T MSWMSW MSW

M2SM1S M3S

INTELLIGENT EYE SENSOR

WIRELESS REMOTE

CONTROLLERSIGNAL

RECEIVER

MS3~

TRANSMISSION CIRCUIT CAUTION

NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN.

BZC101, C102FGF1UH1P~H3PMR10M1FM1S~M3SPCB1~PCB4R1T, R2TS1~S49SW1V1X1M

: BUZZER: CAPACITOR: FRAME GROUND: FUSE: PILOT LAMP : MAGNETIC RELAY: FAN MOTOR: SWING MOTOR: PRINTED CIRCUIT BOARD: THERMISTOR: CONNECTOR: OPERATION SWITCH: VARISTOR: TERMINAL STRIP: PROTECTIVE GROUND

C: 3D060942Q

Page 11: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

10 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 11

Wiring Diagram — Indoor Units

X1MA1P 1KLB 1

A2PH1 2WHT 2 →F1U 3V1TR RED 3 OUTDOOR3.15A

LED LEDLED S1 S26 GRNH211FIELD WIRING.

P1H P2H P3H GRN/YLWTERMINAL FORCENTRALIZED CONTROL

H3CAUTION( )

GND NOTE THAT OPERATION WILLRESTART AUTOMATICALLY IFTHE MAIN POWER SUPPLY ISTURNED OFF AND THEN BACKON AGAIN.

6 3 1S21S1W S1

SIGNALRECEIVER

RED BLKS710101 GRY YLWRTH1 S322 1 2 1 3 C1

WHTNRB NRBt°

Mt° 1~ Q1MPPLR1TINDOOR 130°CBLUR2T M1F

: PROTECTIVE GROUNDC1 : CAPACITOR (M1F)F1U : FUSE

WIRELESS REMOTE

CONTROLLER

TRANSMISSION CIRCUIT

: PILOT LAMP H1P~H3P : FAN MOTORM1F : PRINTED CIRCUIT BOARDA1P~A2P : THERMAL PROTECTOR (FOR MOTOR)Q1M : THERMISTORR1T~R2T

S1~S32, RTH1 : CONNECTOR : OPERATION SWITCHS1W : TRIACV1TR : TERMINAL BLOCKX1M

C: 3D073998B

FDXS09/12LVJU, CDXS15/18/24LVJU

1X1MF1UPCB2~ ~

PCB3 V1 H1 21BLKS26S27 RECTIFIER 33.15AS2W(4) 2WHT OUTDOORH2 RED 3S4W GRNGRN/YLW

MR10 FIELD WIRING.E3E4H3

V2 CAUTIONPCB4SA1 E1S47 S46 GRNS1W

S1F2U 7 E3REDLED2LED1 3.15A

4 MBLU M1FBRNH2PH1PORGWHT1

S42 HAS21 t˚RED 1ORG S49S48M YLWM1SPNK R1TBLU

6 PCB1S41

RED 1 t˚ORGM YLW S32M2S

PNKBLU R2T5

INDOOR

WIRELESS REMOTE

CONTROLLER

SIGNAL RECEIVER

TRANSMISSION CIRCUIT

NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN.

F1U, F2UH1P, H2PM1FM1SM2SPCB1~PCB4R1T, R2TS1~S49S1WS2W(4)S4WX1ME3E4

: PROTECTIVE GROUND: FUSE: PILOT LAMP: FAN MOTOR: SWING MOTOR: LOWER AIR OUTLET MOTOR: PRINTED CIRCUIT BOARD: THERMISTOR: CONNECTOR: OPERATION SWITCH: UPWARD AIR FLOW LIMIT SWITCH: AIR OUTLET SELECTION SWITCH: TERMINAL STRIP: GROUND TERMINAL (HEAT EX.): GROUND TERMINAL (SHIELD PLATE)

C: 3D090604

FVXS09/12/18NVJU

Page 12: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

12 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 13

Wiring Diagrams — Indoor Units

R3TR2TR1T

YLW GRNA1PWHTYLW NOTE)4X24AX2M X19A X18A X17AF1U NOTE)3BLK

F2WHT T1RX10A F1X11ARED P2 P2R1TP1X27A P1GRN/YLW

X5A X1MC1KPRV1TR X20AA3P A4PA1P WH

TYLW

SS1 REDH1PBS1 X25AH2P Q1MSS2 BLKYLWH3P M1FX24A X2A RCH4P TC YLWNOTES) NOTE)3 M1PX1AX1A MSWX36A

M1SNOTE)3 HAPNOTE)3X33AX40A NOTE)3 X35A X15AC1 S1L

T1RX1M

X2MA1P

CONTROL BOX

TO OUTDOOR UNIT

WIRED REMOTE CONTROLLER (OPTIONAL ACCESSORY)

M1~

M1~

RECEIVER/DISPLAY UNIT (OPTIONAL ACCESSORY)

: CONNECTER DISCRIMINATION COLOR FOR COMPONENTS. : CONNECTER COLOR FOR COMPONENTS. : CONNECTER COLOR FOR PRINTED CIRCUIT BOARD.

1. : TERMINAL : FIELD WIRING

, : CONNECTOR : PROTECTIVE GROUND (SCREW) : NOISELESS GROUND

2. IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED INSTALLATION MANUAL.

3. X24A, X33A, X35A AND X40A ARE CONNECTED WHEN THE OPTIONAL ACCESSORIES ARE USED.4. GROUND THE SHIELD OF THE REMOTE CONTROLLER CORD TO THE INDOOR UNIT (IN CASE OF USING SHIELD WIRE).5. SYMBOLS SHOW AS FOLLOWS: RED: RED BLK: BLACK WHT: WHITE YLW: YELLOW GRN: GREEN BLU: BLUE

A1PC1F1UHAP

KPRM1FM1PM1SQ1MR1TR2TR3TS1LT1RV1TRX1MX2MRCTC

R1T

A3PA4PBS1

PRINTED CIRCUIT BOARDCAPACITOR (M1F)FUSE (F, 5A, 250V)PILOT LAMP(SERVICE MONITOR GREEN)MAGNETIC RELAY (M1P)FAN MOTORDRAIN PUMP MOTORSWING LOUVER MOTORTHERMAL PROTECTOR FOR MOTORTHERMISTOR (AIR)THERMISTOR (COIL-1)THERMISTOR (COIL-2)FLOAT SWITCHTRANSFORMER (208-230V/25V)TRIACTERMINAL BLOCKTERMINAL BLOCKSIGNAL RECEIVER CIRCUITSIGNAL TRANSMISSION CIRCUIT

WIRED REMOTE CONTROLLERTHERMISTOR (AIR)

WIRED REMOTE CONTROLLER(RECEIVER/DISPLAY UNIT)

PRINTED CIRCUIT BOARDPRINTED CIRCUIT BOARDPUSH BUTTON SWITCH (ON/OFF)

H1P

H2P

H3P

H4P

SS1

SS2

X24A

X33A

X35A

X40A

PILOT LAMP(ON-RED)PILOT LAMP(TIMER-GREEN)PILOT LAMP(FILTER SIGN-RED)PILOT LAMP(DEFROST-ORANGE)SELECTOR SWITCH(MAIN/SUB)SELECTOR SWITCH(WIRELESS ADDRESS SET)

CONNECTOR FOR OPTIONAL PARTSCONNECTOR (WIRELESS REMOTE CONTROLLER)CONNECTOR(ADAPTOR FOR WIRING)CONNECTOR(GROUP CONTROL ADAPTOR)CONNECTOR(ON/OFF INPUT FROM OUTSIDE)

123

t˚˚t ˚t

C: 3D080351A

FFQ09/12/15/18LVJU

Page 13: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

12 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 13

Wiring Diagram — Outdoor Units

2MXS

18NM

VJU

GRN/Y

LWM1

CPC

B2SW

6SW

4SW

2X1

MLE

DPO

WER

SUP

PLY

5SW

5A

42

3SW

3SW

11

BRN

L1L1

BLU

M1F

S2L2

L2S5

01S5

0211

15

1Z2

C N=

4MS

BLK

BLU

REDYLW

BLU

REDYLW

WHT

X2M

11

Y1S

X11A

GRN

BLUPPL

GRN

BLK

BRN

GRN

REDORG

GRY

BLK

BRN

RED

Z5C

N=2

YLW

YLW

WHTSKY BLU

22

PCB1

E1E2

33

111

15

BLU

ORG

RED

BRN

YLW

YLW

WHT

S202

S201

BLKWHT

SA1

X3M

13

71

324W

UV1

1S7

0S8

0V2

2MR

M20

HL1

23

3MR

M10

MR4

ZFV3

HN1

WU

DB1

VDC

++

++

V401

PSRE

D1

C110

YLW

S-

-DC

-IP

M19

S90

S93

S40

S92

S23

1S2

2S2

110

111

58

11

4

BLU

RED

RED

BLUORG

BLK

GRY

BLK

GRY

BLK

BLK

BLKBLK

GRY

ORGYLW

YLW

WHT

WHT

t˚t˚

t˚t˚

t˚t˚

t˚M

MR5T

R2TR4T

R9TR1T

R3TR10

TQ1

LY2

EY1

E

(DISCHARGE)(CONDENSER)(OUTDOOR)

INDO

OROU

TDOO

R

FIELD

WIRI

NG

TO IN

DOOR

UNI

T RO

OM B

TO IN

DOOR

UNI

T RO

OM A

SHEE

T ME

TAL

Z1C

N=3

FU3

30A

Z4C

N=3

ROOM

A1

S20

15

ROOM

B1

5RO

OM C

15

ROOM

D

FU1

3.15A

(ROOM A)(ROOM B)

(ROOM A)(ROOM B)

<GAS

PIP

E><LI

QUID

PIP

E>

FU2

3.15A

~ ~

IN CA

SE OF

HE

AT PU

MP TY

PE

Z6C

N=1

MS

3 ~

Z3C

N=3

C110

DB1

FU1,

FU2,

FU3

IPM1

L1, L

2LE

D1~L

ED5,

LEDA

M1C

M1F

: CAP

ACIT

OR: D

IODE

BRI

DGE

: FUS

E: IN

TELL

IGEN

T PO

WER

MOD

ULE

: LIV

E: P

ILOT

LAMP

: COM

PRES

SOR

MOTO

R: F

AN M

OTOR

MRM1

0, MR

M20

MR4

PCB1

, 2PS Q1

LR1

T~R5

T, R9

T, R1

0TSA

1SH

EET

META

L

: MAG

NETI

C RE

LAY

: MAG

NETI

C RE

LAY

: PRI

NTED

CIR

CUIT

BOA

RD: S

WIT

CHIN

G PO

WER

SUP

PLY

: OVE

RLOA

D PR

OTEC

TOR

: THE

RMIS

TOR

: SUR

GE A

RRES

TER

: TER

MINA

L STR

IP F

IXED

PLA

TE

SW1

SW2

SW3

SW4

SW5

SW6

V2, V

3, V4

01X1

M~X3

M

: FOR

CED

OPER

ATIO

N ON

/OFF

SW

(SW

1): F

ORCE

D OP

ERAT

ION

MODE

SEL

ECT

SW (S

W2)

: WIR

ING

ERRO

R CH

ECK

SW (S

W3)

: PRI

ORIT

Y RO

OM S

ETTI

NG S

W (S

W4)

: FUN

CTIO

N SW

(SW

5): N

IGHT

QUI

ET M

ODE

SETT

ING

SW (S

W6)

: VAR

ISTO

R: T

ERMI

NAL S

TRIP

Y1E~

Y2E

Y1S

Z1C~

Z6C

ZF S, S

2~S5

02U,

V, W

X11A

: ELE

CTRO

NIC

EXPA

NSIO

N VA

LVE

COIL

: REV

ERSI

NG S

OLEN

OID

VALV

E CO

IL: F

ERRI

TE C

ORE

: NOI

SE F

ILTER

: CON

NECT

OR: C

ONNE

CTOR

: CON

NECT

OR

YLW

BL

URE

DW

HT

3D09

2458

Page 14: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

14 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 15

Wiring Diagrams — Outdoor Units

3MXS

24NM

VJU

GRN/

YLW

M1C

PCB2

SW2

SW6

SW4

X1M

POWE

R SU

PPLY

LED

14

SW1

25

SW5

3SW

3A

L1L1

BRN

BLU

M1F

S2L2

L2S5

01S5

0211

15

1MS

BLU

REDYLW

BLKWHT

X2M

11

Y1S

X11A

GRN

GRN

22

PCB1

3E2

E13

511

11

BLU

REDYLW

YLW

YLW

ORGBRN

RED

BLU

WHT

S201

S202

BLKWHT

SA1

X3M

11

34

32

7VUW

11

S70

S80

V2MR

M20

2HL

12

33

MRM1

0MR

4ZF

V3

BLKWHT

HN1

X4M

11

WVU

DB1

DC+

22

++

+V4

01PS

13

3C1

10S

RED

YLW

BLU

~~ --

DC-

IPM1

9S4

0S9

3S9

2S9

010

81

11

11

11

111

4

BLK

BLK

BLK

GRY

BRN

BLK

BLK

BLK

GRY

GRY

YLW

BLUORG

BLU

BLU

ORG

RED

ORG

RED

RED

YLW

YLW

YLW

WHT

WHT

WHT

t˚t˚

t˚t˚

t˚t˚

˚t˚t

˚tM

MM

R10T

R9TR2T

R6TR3T

R4TR5T

R11T

R1TQ1

LY2

EY1

EY3

E

(ROOM C)

(ROOM A)(ROOM B)

(ROOM C)(ROOM B)(ROOM A)

(DISCHARGE)(CONDENSER)(OUTDOOR)

OUTD

OOR

INDO

OR< G

AS P

IPE>

< LIQ

UID

PIPE

>

FIELD

WIRIN

G

S20

5S2

15

S22

5S2

35

Z1C

N=3

Z5C

N=2

FU2

3.15A

Z3C

N=3

Z6C

N=1

IN CA

SE OF

HE

AT PU

MP TY

PE

GRN

GRY

BLK

BLK

ORG

PPLBLU

BRN

REDBRN

RED

YLW

YLW

WHTSKY BLU

Z2C

N=4

C110

DB1

FU1,

FU2,

FU3

IPM1

L1, L

2LE

D1~L

ED5,

LEDA

M1C

M1F

: CAP

ACIT

OR: D

IODE

BRI

DGE

: FUS

E: IN

TELL

IGEN

T PO

WER

MOD

ULE

: LIV

E: P

ILOT

LAMP

: COM

PRES

SOR

MOTO

R: F

AN M

OTOR

: MAG

NETI

C RE

LAY

: MAG

NETI

C RE

LAY

: PRI

NTED

CIR

CUIT

BOA

RD: S

WIT

CHIN

G PO

WER

SUP

PLY

: OVE

RLOA

D PR

OTEC

TOR

: THE

RMIS

TOR

: SUR

GE A

RRES

TER

: TER

MINA

L STR

IP F

IXED

PLA

TE

MRM1

0, MR

M20

MR4

PCB1

, 2PS Q1

LR1

T~R6

T, R

9T~R

11T

SA1

SHEE

T ME

TAL

SW1

SW2

SW3

SW4

SW5

SW6

V2, V

3, V4

01X1

M~X4

M

: FOR

CED

OPER

ATIO

N ON

/OFF

SW

(SW

1): F

ORCE

D OP

ERAT

ION

MODE

SEL

ECT

SW (S

W2)

: WIR

ING

ERRO

R CH

ECK

SW (S

W3)

: PRI

ORIT

Y RO

OM S

ETTI

NG S

W (S

W4)

: FUN

CTIO

N SW

(SW

5): N

IGHT

QUI

ET M

ODE

SETT

ING

SW (S

W6)

: VAR

ISTO

R: T

ERMI

NAL S

TRIP

Y1E~

Y3E

Y1S

Z1C~

Z6C

ZF S, S

2~S5

02U,

V, W

X11A

: ELE

CTRO

NIC

EXPA

NSIO

N VA

LVE

COIL

: REV

ERSI

NG S

OLEN

OID

VALV

E CO

IL: F

ERRI

TE C

ORE

: NOI

SE F

ILTER

: CON

NECT

OR: C

ONNE

CTOR

: CON

NECT

OR

MS

3~

ROOM

AW

HTRE

DRO

OM B

BLU

ROOM

CRO

OM D

YLWFU

1 3.1

5A

FU3

30A

Z4C

N=3

TO IN

DOOR

UNIT

ROOM

B

TO IN

DOOR

UNIT

ROOM

A

TO IN

DOOR

UNIT

ROOM

C

SHEE

T ME

TAL

3D09

2460

Page 15: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

14 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 15

Wiring Diagram — Outdoor Units

4MXS

36NM

VJU

GRN/Y

LWM1

CPC

B2SW

4SW

2SW

6LE

DPO

WER

SUPP

LYX1

M5

SW1

SW3

12

BRN

SW5

A3

4L1

L1BL

UM1

FS2

L2L2

S501

S502

15

111

Z2C

N=4

MS

BLU

RED

BLK

YLW

WHTX2

M

SKY BLU

11

Y1S

X11A

RED

GRN

ORG

GRN

BRN

BLK

BLK

GRN

BRN

PPLGRY

BLU

RED

Z5C

N=2

YLW

YLW

WHT

22

PCB1

E2E1

33

111

15

BLU

RED

ORG

RED

BLUBRN

YLW

YLW

YLW

WHT

S201

S202

BLKWHT

SA1

X3M

132

37

14

UW

V1

1S7

0S8

0V2

2HL

1MR

M20

23

3MR

M10

MR4

ZFV3

BLKWHT

HN1

X4M

11

VUDB

1W

DC+

22

++

V401

PS3

RED

13

C110

YLW

BLKWHT

X5M

SBL

U-

11

DC-

ORG

IPM1

22

93

3S4

0S9

3S9

0S9

21

105

41

511

15

11

81

51

1S2

0S2

2S2

3S2

1

BLK

RED

ORG

BLU

BLU

BLU

BLK

GRY

ORG

RED

BLK

BLU

BLU

BLK

GRY

GRY

RED

BLK

BRN

ORG

BLK

RED

RED

ORG

YLW

YLW

YLW

YLW

YLW

WHT

WHT

WHT

WHT

t˚t˚

t˚t˚

t˚t˚

t˚t˚

t˚t˚

t˚M

MM

MR2T

R5TT9R

T01RR4T

R3TR12

TR11

TR1T

T6RT7R

Q1L

Y2E

Y4E

Y1E

Y3E

(ROOM C)

(ROOM A)

(ROOM D)

(ROOM B)

(ROOM C)

(ROOM A)

(ROOM D)

(ROOM B)

(DISCHARGE)(CONDENSER)(OUTDOOR)

OUTD

OOR

INDO

OR

FIELD

WIRI

NG

SHEE

T ME

TAL

TO IN

DOOR

UNIT

ROOM

B

TO IN

DOOR

UNIT

ROOM

A

TO IN

DOOR

UNIT

ROOM

C

TO IN

DOOR

UNIT

ROOM

D

Z1C

N=3

FU3

30A

Z4C

N=3

ROOM

ARO

OM B

ROOM

CRO

OM D

FU1

3.15A

~ ~

+ -

FU2

3.15A

IN CA

SE OF

HE

AT PU

MP TY

PE

Z6C

N=1

MS

3 ~

Z3C

N=3

<GAS

PIP

E><LI

QUID

PIP

E>C1

10DB

1FU

1, FU

2, FU

3lP

M1L1

, L2

LED1

~LED

5, LE

DAM1

CM1

F

: CAP

ACITO

R: D

IODE

BRI

DGE

: FUS

E: IN

TELL

IGEN

T PO

WER

MOD

ULE

: LIV

E: P

ILOT

LAMP

: COM

PRES

SOR

MOTO

R: F

AN M

OTOR

MRM1

0, MR

M20

MR4

PCB1

, 2PS Q1

LR1

T~R7

T, R9

T~R1

2TSA

1SH

EET

META

L

: MAG

NETI

C RE

LAY

: MAG

NETI

C RE

LAY

: PRI

NTED

CIR

CUIT

BOA

RD: S

WIT

CHIN

G PO

WER

SUP

PLY

: OVE

RLOA

D PR

OTEC

TOR

: THE

RMIS

TOR

: SUR

GE A

RRES

TER

: TER

MINA

L STR

IP F

IXED

PLA

TE

SW1

SW2

SW3

SW4

SW5

SW6

V2, V

3, V4

01X1

M~X5

M

: FOR

CED

OPER

ATIO

N ON

/OFF

SW

(SW

1): F

ORCE

D OP

ERAT

ION

MODE

SEL

ECT

SW (S

W2)

: WIR

ING

ERRO

R CH

ECK

SW (S

W3)

: PRI

ORIT

Y RO

OM S

ETTI

NG S

W (S

W4)

: FUN

CTIO

N SW

(SW

5): N

IGHT

QUI

ET M

ODE

SETT

ING

SW (S

W6)

: VAR

ISTO

R: T

ERMI

NAL S

TRIP

Y1E~

Y4E

Y1S

Z1C~

Z6C

ZF S, S

2~S5

02U,

V, W

X1

1A

: ELE

CTRO

NIC

EXPA

NSIO

N VA

LVE

COIL

: REV

ERSI

NG S

OLEN

OID

VALV

E CO

IL: F

ERRI

TE C

ORE

: NOI

SE F

ILTER

: CON

NECT

OR: C

ONNE

CTOR

: CON

NECT

OR

WHT

RED

BLU

YLW

3D08

9856

Page 16: MXS Series - Daikinshumate.daikincomfort.com/media/pdfs/spec_sheets/SS-MXS.pdfUp to 19.9 SEER Up to 12.7 EER Up to 12.5 HSPF ... 2 SS-MXS SS-MXS 3 Product Specifications Outdoor Units

16 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com PB

Our continuing commitment to quality products may mean a change in specifications without notice. © 2015 • Houston, Texas • Printed in the USA.

Wiring Diagram — Outdoor Unit

Accessories

Indoor Unit

BRC1E72 Wired Navigation Remote Controller (For FFQ Ceiling Cassette Only)

BRC944B2-A08 Wired Controller (For Wall Mount and Slim Duct Units Only) with a 26' cord

BYFQ60B3W1 Decoration Panel for FFQ Ceiling Cassette, ships separately at no charge

DACA-CP3-1 Condensate Pump with Integral Float Switch

DACA-TS1-1 Daikin ENVi Intelligent Thermostat Kit (For Wall Mount and Slim Duct Units Only)

BP Unit

KHRP26A22T REFNET Joint

Outdoor Unit

DACA-WB-3 Powder Coated Wall Mounted Bracket