4
Improved efficiency, safety, usability, servicability design MVE H Eco Series The Next Generation High Efficiency Freezer from Chart MVE With Chart MVE, the best keeps getting better.

MVE HEco Series - Thermo Fisher Scientific...MVE HEco MVE HEco MVE HEco 815P-190 1536P-190 1879P-190 Maximum Storage Capacity 1.2 & 2 ml Vials (Internally Threaded) 15,600 36,40079,950

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MVE HEco Series - Thermo Fisher Scientific...MVE HEco MVE HEco MVE HEco 815P-190 1536P-190 1879P-190 Maximum Storage Capacity 1.2 & 2 ml Vials (Internally Threaded) 15,600 36,40079,950

Improvedefficiency,safety,usability,servicability,design

MVE HEco Series

The Next Generation High Efficiency Freezer from Chart MVE

With Chart MVE, the best keeps getting better.

Page 2: MVE HEco Series - Thermo Fisher Scientific...MVE HEco MVE HEco MVE HEco 815P-190 1536P-190 1879P-190 Maximum Storage Capacity 1.2 & 2 ml Vials (Internally Threaded) 15,600 36,40079,950

2 ML-CRYO0002 C

MVE HEco Series

Chart MVE never stops working to improve products that will better fulfill customer needs and requests. The newest member of the MVE family is the reimagined and redesigned MVE HEco Series. The new MVE HEco Series freezers provide a 20% reduc-tion in LN2 usage, making them the most efficient vapor freezers available. These next generation high efficiency freezers incor-porate hinged work surfaces that fully enclose all electronics and plumbing to enhance overall safety and usability. The technical and visual improvements provide a more aesthetically pleasing freezer while offering greater functionality. As with all of MVE’s cryogenic freezers, the MVE HEco Series freezers provide maxi-mum storage density as well as the industry’s longest hold time and highest sample security.

Features include:• 20% reduction in LN2 usage• Fully enclosed wiring and plumbing• Dry sample storage• -190°C top box temperature• Lowest liftover height • Two tier folding step

-200

-180

-160

-140

-120

-100

-80

-60

-40

-20

0

20

TEM

PERA

TURE

°C

DAYS

MVE HEco 1536P Temperature Test*

Top Box

Bottom Box

0 5 10 15 20 25 30 35

Freezerfirst filled

Lid Open Test-170°C Max

(2 Days)LN2 Supply Removed at

Day 13

Temperaturecrosses -135°C21 days afterLN2 Supplyremoved

40

Temperature Test Graph* Temp Test indicates typical performance of HEco Series

-190°C freezer with full inventory system and factory recommended level settings. Actual performance may vary

with atmospheric conditions and usage.

Page 3: MVE HEco Series - Thermo Fisher Scientific...MVE HEco MVE HEco MVE HEco 815P-190 1536P-190 1879P-190 Maximum Storage Capacity 1.2 & 2 ml Vials (Internally Threaded) 15,600 36,40079,950

MVE HEco Series 3

MV

E H

Eco

Seri

es

0 10 20

Brand B

Brand A

MVE

HOLD TIME (DAYS)

Longest Vapor Safety Hold Time

12

8

4

0Brand BBrand AMVE

NER

(LN

2 L/

DAY)

Energy Usage30% More Energy Efficient

Hinged work surfaces for improved safety and usability

No exposed wiring or cold surfaces

Completely encolsed plumbing assembly which is still easily accessed when needed

Fully integrated control system, power system, and battery backup

Page 4: MVE HEco Series - Thermo Fisher Scientific...MVE HEco MVE HEco MVE HEco 815P-190 1536P-190 1879P-190 Maximum Storage Capacity 1.2 & 2 ml Vials (Internally Threaded) 15,600 36,40079,950

Copyright © 2013 Chart Industries Ref ML-CRYO0002 CChart Inc. reserves the right to discontinue its products, or change the prices, materials, equipment, quality, descriptions, specifications and/or processes to its products at any time without prior notice and with no further obligation or consequence. All rights not expressly stated herein are reserved by us, as applicable.

Go to www.chartbiomed.com for more information.

TWO Year Standard Warranty • FIVE Year Vacuum WarrantyConforms to MDD 93/42/EEC, the Medical Device Directive for the EU. Freezer systems UL/C-UL Listed.* Without inventory**Minimum width required for vessel to pass through opening. Footprint may vary. Contact Tech Service for detailed drawings.

Rack LayoutsSquare Rack Layout (P) 4R9951 Layout (R)

MVE HEco MVE HEco MVE HEco 815P-190 1536P-190 1879P-190

Maximum Storage Capacity1.2 & 2 ml Vials (Internally Threaded) 15,600 36,400 79,950Number of Racks 100 cell boxes 12 24 54Number of Racks 25 cell boxes 4 16 30Number of Stages per Rack 12 13 13High Security Straw Capacity (0.5 ml) 36,960 100,800 236,880Number of Canisters (73 mm) 55 120 282Goblets/Canister : Straws/Goblet 4:168 5:168 5:168

PerformanceLN2 Capacity L 370 730 1745LN2 Capacity Under Tray L 52 115 318Static Hold Time—Vapor days 13 21 35Static Hold Time—Liquid Full days 77 120 174

Unit DimensionsNeck Opening in. (mm) 17.4 (442)Usable Internal Height in. (mm) 26.6 (676) 28.8 (732) 29.5 (749)Inner Diameter in. (mm) 28.8 (731) 38.5 (978) 56.0 (1422)Overall Height in. (mm) 49.0 (1245) 54.7 (1389) 62.1 (1577)Liftover Height in. (mm) 40.0 (1004) 37.3 (947) 38.8 (985)Door Width Requirement** in. (mm) 32.0 (813) 42.0 (1067) 60.0 (1524)Weight Empty lb. (kg) 475 (215) 700 (318) 1606 (728)Weight Liquid Full* lb. (kg) 1134 (514) 2000 (907) 4585 (2080)

Blood Bag Capacities Total Bags Bags/Frame No. Frames Total Bags Bags/Frame No. Frames Total Bags Bags/Frame No. Frames

791 OS/U (25 ml) 1,224 6 204 2,905 7 415 5,866 7 838Compact (25ml) 2,064 8 258 4,338 9 482 8,622 9 9584R9951 (50 ml) 768 6 128 1,488 6 248 2,952 6 4924R9953 (250 ml) 416 4 104 812 4 203 1,584 4 3964R9955 (500 ml) 304 4 76 608 4 152 1,104 4 276DF200 (200 ml) 236 4 59 496 4 124 960 4 240DF700 (700 ml) - - - 256 4 64 504 4 126

©2014 Thermo Fisher Scientific Inc. All rights reserved. A.B.N. 52 058 390 917

For customer service, call 1300-735-292To fax an order, use 1800-067-639Visit us online: www.thermofisher.com.au