Upload
jonymismo
View
9
Download
4
Embed Size (px)
DESCRIPTION
catalogo Moeller powerpoint.
Citation preview
Schutzverm
erk ISO
16016 beachten04/18/23
Dateinam
e
Moeller GmbH / MD-PMM / EdelmannSeite - 1
Competitive comparison of contactor DILM up to 170A
Moeller GmbH / MD-PMM / EdelmannPage - 2
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Usability of features argument for DILM up to 170A
Cage tension spring as connection method
for control current connections up to 150A
for main connections and control connections up to 12A
Same installation depth for
AC and DC actuated contactors
Double box terminal throughout
DC-actuated contactors 32A direct
controllable from PLC
Front control connections
Reliable connection of various
line cross-sections
Avoids costs for coupling relays/contactors Minimises planning
Faster wiring reduces assembly costs Maintenance-free High contact reliability even with vibrations
Same accessories for both types reduces type variety simpler planning
AC DC
SPS
DILM
Easier accessibility to the connections
ensures high rate of wiring safety
Moeller GmbH / MD-PMM / EdelmannPage - 3
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Usability of features argument for DILM up to 170A
Integrated protective circuit for
DC-actuated contactors
Very low standby power (DC)
Combined plug technique for contactors up to 15A
SmartWire control up to 32A
Contactors with integrated auxiliary switch up to 32A
DC
Reduces costs for protecting from voltage peaks Reduced assembly time
Minimises costs for switch-cabinet venting / - cooling Reduces costs because control transformer can be designed smaller
Faster and easier wiring when installing combination of contactor circuit and motor starter- saves assembly time
Reduces costs for additional auxiliary switches Reduces assembly time
Faster and safer wiring reduces assembly/test times Control and diagnostics of contactors and motor starter combination
Moeller GmbH / MD-PMM / EdelmannPage - 4
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Usability of features argument for DILM up to 170A
Wide control voltage range
(0.7…1.2 x Uc) for DC-actuated contactors
Extended voltage safety for
reliable contactor control in
unstable networks
DC
Moeller GmbH / MD-PMM / EdelmannPage - 5
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison 3RT10… and DILM
Mech. lifetime of smallest
size (30Mio.)
With lower frequency of switching and comparable elec. lifetime
Value only applies without auxiliary switch
Lower output power for DC-contactors up to 95A
With higher standby power
Actuation by PLC only ensured up to 25A
Lower DC standby power
Integrated protection circuitry for DC-actuated contactors
Normally, smaller or same installation depths
Higher AC-4 currents can be switched with same lifetime
Moeller GmbH / MD-PMM / EdelmannPage - 6
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison 3RT10… and DILM
From 115A Actuated by AS interface, Profibus DP and display of remaining lifetime
At cost of larger width and higher list price
Lower installation depths (AC)
At cost of higher width at which
most applications are critical Wide-frequency coils for AC- (40…60 Hz) or
DC- actuation for sizes from 115A
Higher list price
DILM is normally the cheaper contactors (AC and DC)
Moeller GmbH / MD-PMM / EdelmannPage - 7
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison of TeSys Model D and DILM
Up to 38A four connection possibilities (screw, spring-type, flat-cable and ring-cable ferrule connection)
Screw and spring-type connections sufficient for European market
2 auxiliary switches (NOC and NCC) in device up to 95A
After consultation with customers, one auxiliary switch is normally enough for most applications
Lower standby power for DC actuated contactors
Double box terminal throughout
Used at -25°C to 60°C
(at Schneider -5°C to 60°C)
Normally, smaller or same installation depths
Moeller GmbH / MD-PMM / EdelmannPage - 8
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison of TeSys Model D and DILM
Additional contactor series with (GL) very low pull-in power and standby power
Only up to 38A
Only one auxiliary switch on front with 2 contacts can be used; no AS on side can be side
Auxiliary switches can be used for entire series
Additional washers required for AS from 40A
For DC, AS on side can only be used from 115A
DC-actuated contactor (DILM9, 12)
up to 50% lower list price
Higher AC-4 currents can be switched with same lifetime
Moeller GmbH / MD-PMM / EdelmannPage - 9
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison of TeSys Model D and DILM
Lower installation depth for AC contactors
Higher installation depth DC contactors
installation width is critical in most applications; normally, this is lower for DILM
1000V from 40A switchable
High voltages only used at high powers; from DILM185, Moeller contactors also suitable for 1000V
Moeller GmbH / MD-PMM / EdelmannPage - 10
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison A9 to A185 and DILM
Double box terminal throughout
(for ABB only up to 37A (AL40))
Same or less installation widths
Lower pull-in power and standby power (AC and DC)
9 to 10 auxiliary switches can be installed on medium type series (37A to 110A)
9 to 10 auxiliary switches are irrelevant for most applications
1000V from 50A switchable
High voltages only used at high powers; from DILM185, Moeller contactors also suitable for 1000V
Moeller GmbH / MD-PMM / EdelmannPage - 11
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison A9 to A185 and DILM
Much better values for DC contactors from 50A
12 x higher mechanical switching frequency
½ pull-in power
double mech. lifetime
Electrical protection integrated throughput (for ABB only from 50A)
Wider working range of coil at 0.7…1,2x Uc
(for ABB 0.85…1.1x Uc)
Up to 37A (AL40) higher switching frequency (AC-3) and higher electrical lifetime
From 50A lower electrical lifetime
1.3 mio. switching cycles are sufficient for
machine lifetime Special series from 50 to 110A with very wide
actuation voltages for AC and DC
Higher list price
High radiation values (use in public low-voltage network requires additional measure)
Moeller GmbH / MD-PMM / EdelmannPage - 12
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison A9 to A185 and DILM
Use of -40°C to 70°C
Only without thermal overload relay
-25°C is suitable for use in switching-cabinet
At low working range of coil 0.85…1,1xUc | ≤55°C
1xUc | 55…70°C
Moeller GmbH / MD-PMM / EdelmannPage - 13
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison 100-C, 100-D and DILM
Same or less installation widths
Lower values for pull-in power and standby power (AC & DC)
Integrated protection circuitry for DC-actuated contactors
for Rockwell only from 60A
8 auxiliary switches can be installed throughout
From 95A 2, auxiliary switch in basic device
After consultation with customers, one auxiliary switch is normally enough for most applications
Up to 85A one accessory for all sizes
Moeller GmbH / MD-PMM / EdelmannPage - 14
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison 100-C, 100-D and DILM
Wider voltage range for DC contactors with 0.7…1.2 x Uc
for Rockwell 08/0.85…1.1 x Uc
Higher electrical lifetime for AC-3 applications
Lower installation depth up to 18.5 kW
Lower average prices
1000V from 95A switchable High voltages only used at high powers; from DILM185, Moeller contactors also suitable for 1000V
Moeller GmbH / MD-PMM / EdelmannPage - 15
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison 100-C, 100-D and DILM
Spring-type terminal and screw connection technology
Only screw connections for Rockwell
Double box terminal throughout
Simple box terminal or ring-cable ferrule connection for Rockwell
Moeller GmbH / MD-PMM / EdelmannPage - 16
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison CL00A to CK08 (GE/AEG) and DILM
From 22 kW AC/DC coils
Higher mech. lifetime (15… 20 mil.)
Higher elec. lifetime (1.5…2 Mil.)
Same or less installation widths
The cheaper contactor
DC wide-range coils with
0.7…1.2 x Uc (at GE 0.8…1.1)
Moeller GmbH / MD-PMM / EdelmannPage - 17
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison CL00A to CK08 (GE/AEG) and DILM
From 22 kW actuated by AC/DC electronics
Due to low voltage tolerances, less reliability in unstable networks
Higher elec. lifetime (1.5…2 Mil.)
1,3 mio. switching cycles are sufficient for machine lifetime
Same or less installation widths
Used at -25°C to 60°C
At GE -25…55°C
DC wide-range coils with
0.7…1.2 x Uc
At GE 0.8…1.1
Moeller GmbH / MD-PMM / EdelmannPage - 18
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison CWM9 to CWM180 (WEG) and DILM
Double box terminal throughout
For WEG, double box terminals for contactors for 32…105A
Integrated protection circuitry for DC-actuated contactors
DC wide-range coils with
0.7…1.2 x Uc (for WEG 0.8…1.1)
1 auxiliary switch on side can be used for all sizes
Moeller GmbH / MD-PMM / EdelmannPage - 19
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Comparison CWM9 to CWM180 (WEG) and DILM
Lower values for pull-in power and standby power for AC and DC actuated contactors
Same or less installation widths
Moeller GmbH / MD-PMM / EdelmannPage - 20
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Layout 1 DILM
Advantage of competitor
Counter-argument
Advantages of Moeller
Picture of competitor
Moeller GmbH / MD-PMM / EdelmannPage - 21
Observe protection m
ark to ISO
1601604/18/23
Dateinam
e
Layout 2 DILM
Advantage of competitor
Counter-argument
Advantages of Moeller
Picture of competitor