17
www.moxa.com email: [email protected] www.moxa.com email: [email protected] Remote Monitoring Solutions 5-28 5 Remote I/O > ioLogik 4000 Modular Remote I/O Digital Input Modules Specs Model M-1400 M-1401 M-1410 M-1411 M-1800 M-1801 M-1600 M-1601 M-1450 M-1451 Channels 4 4 4 4 8 8 16 16 4 4 Sink/Source Sink Source Sink Source Sink Source Sink Source Connector RTB RTB RTB RTB RTB RTB 20-pin 20-pin RTB RTB Voltage 24 VDC 24 VDC 48 VDC 48 VDC 24 VDC 24 VDC 24 VDC 24 VDC 110 VAC 220 VAC Isolation Optical isolation Digital Output Modules Specs Model M-2400 M-2401 M-2800 M-2801 M-2600 M-2601 M-2402 M-2403 M-2404 M-2405 M-2250 M-2254 Channels 4 4 8 8 16 16 4 4 4 4 2 2 Sink/Source Sink Source Sink Source Sink Source Sink Source Sink Source Relay Triac Connector RTB RTB RTB RTB 20-pin 20-pin RTB RTB RTB RTB RTB RTB Voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 230 VAC/ 24 VDC 12 to 125 VDC Current 0.5A 0.5A 0.5A 0.5A 0.3A 0.3A 0.5A 0.5A 2.0A 2.0A 2.0A 0.5A Isolation Optical isolation Diagnostics Yes Yes Yes Yes Analog Input Modules Specs Model M-3400 M-3402 M-3410 M-3412 M-3414 M-3401 M-3403 M-3411 M-3413 M-3415 M-6200 M-6201 Channels 4 4 4 4 4 4 4 4 4 4 2 2 Current 0 to 20 mA 4 to 20 mA 0 to 20 mA 4 to 20 mA Voltage 0 to 10V -10 to 10V 0 to 5V 0 to 10V -10 to 10V 0 to 5V Connector RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB Resolution 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit Isolation Optical isolation Sensor Input RTD (Ohm) Thermo- couple (µV) Analog Output Modules Specs Model M-4201 M-4202 M-4210 M-4211 M-4212 Channels 2 2 2 2 2 Current 0 to 20 mA 4 to 20 mA Voltage 0 to 10V -10 to 10V 0 to 5V Resolution 12-bit 12-bit 12-bit 12-bit 12-bit Connector RTB RTB RTB RTB RTB Isolation 1K VDC galvanic isolation Modular Remote I/O Selection Guide I/O Modules Power Modules Specs Model M-7001 M-7002 M-7803 M-7804 M-7805 M-7806 Channels 0 0 8 8 8 8 Voltage 24 VDC DC: 5, 24, 48 VDC AC: 110/220 VAC - 0 V 24 VDC 4 for 0 VDC 4 for 24 VDC Purpose System power Field power Shield signal Field power Field power Field power

Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

Embed Size (px)

Citation preview

Page 1: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-28 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-28

5

Rem

ote I/O >

ioLogik 4000 Modular R

emote I/O

Digital Input Modules

Specs

Model M-1400 M-1401 M-1410 M-1411 M-1800 M-1801 M-1600 M-1601 M-1450 M-1451

Channels 4 4 4 4 8 8 16 16 4 4

Sink/Source Sink Source Sink Source Sink Source Sink Source – –

Connector RTB RTB RTB RTB RTB RTB 20-pin 20-pin RTB RTB

Voltage 24 VDC 24 VDC 48 VDC 48 VDC 24 VDC 24 VDC 24 VDC 24 VDC 110 VAC 220 VAC

Isolation Optical isolation

Digital Output Modules

Specs

Model M-2400 M-2401 M-2800 M-2801 M-2600 M-2601 M-2402 M-2403 M-2404 M-2405 M-2250 M-2254

Channels 4 4 8 8 16 16 4 4 4 4 2 2

Sink/Source Sink Source Sink Source Sink Source Sink Source Sink Source Relay Triac

Connector RTB RTB RTB RTB 20-pin 20-pin RTB RTB RTB RTB RTB RTB

Voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 230 VAC/ 24 VDC

12 to 125 VDC

Current 0.5A 0.5A 0.5A 0.5A 0.3A 0.3A 0.5A 0.5A 2.0A 2.0A 2.0A 0.5A

Isolation Optical isolation

Diagnostics – – – – – – Yes Yes Yes Yes – –

Analog Input Modules

Specs

Model M-3400 M-3402 M-3410 M-3412 M-3414 M-3401 M-3403 M-3411 M-3413 M-3415 M-6200 M-6201

Channels 4 4 4 4 4 4 4 4 4 4 2 2

Current 0 to 20 mA

4 to 20 mA – – – 0 to 20

mA4 to 20

mA – – – – –

Voltage – – 0 to 10V -10 to 10V 0 to 5V – – 0 to 10V -10 to

10V 0 to 5V – –

Connector RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB

Resolution 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit – –

Isolation Optical isolation

SensorInput – – – – – – – – – – RTD

(Ohm)

Thermo-couple(µV)

Analog Output Modules

Specs

Model M-4201 M-4202 M-4210 M-4211 M-4212

Channels 2 2 2 2 2

Current 0 to 20 mA 4 to 20 mA – – –

Voltage – – 0 to 10V -10 to 10V 0 to 5V

Resolution 12-bit 12-bit 12-bit 12-bit 12-bit

Connector RTB RTB RTB RTB RTB

Isolation 1K VDC galvanic isolation

Modular Remote I/O Selection Guide

I/O Modules

Power Modules

Specs

Model M-7001 M-7002 M-7803 M-7804 M-7805 M-7806

Channels 0 0 8 8 8 8

Voltage 24 VDC DC: 5, 24, 48 VDCAC: 110/220 VAC - 0 V 24 VDC 4 for 0 VDC

4 for 24 VDC

Purpose System power Field power Shield signal Field power Field power Field power

Page 2: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

emai l : [email protected] www.moxa.com 5-5-29

Industrial Networking Solutions

Ethernet network adaptor module

emai l : [email protected] www.moxa.com 5-29

5

Rem

ote I/O >

NA-4010

NA-4010

0 1

2 3

4 5

6 7

CH0 CH0

CH0 CH0

CH0 CH0

CH0 CH0

ioLogik 4000Modbus TCP/IPNA-4010

SYSLINKACTIVEI/O

FieldPower

0 1

2 3

4 5

6 7

SG

Field Power (0 VDC)Field Power (24 VDC)

SG

24V 0V

0V 0V

24V 24V

System Power (0 VDC)

System Power (24 VDC)

Field Power (0 VDC)

Field Power (24 VDC)

Shielding Ground

System Power (5 VDC)System Power (GND)

System Bus

Non-isolationSwitchingPower

Specifi cations

NetworkEthernet: 10/100 Mbps, RJ45

Software Features Protocols: Modbus/TCP, HTTP, BootpIP Settings: ARP, Bootp, static IPUtility: ioAdminProgramming Library: MXIO DLL library for Windows supporting Visual Basic, Visual C++, Borland C++ BuilderNumber of I/O Modules: Max. of 32 I/O expansion modules

Power Requirements Power Input: 11 to 28.8 VDC, 24 VDC typicalPower Consumption: 60 mA typical @ 24 VDCCurrent for I/O Modules: Max. 1.5A @ 5 VDC

Field Power Rated Voltage: 11 to 28.8 VDC, 24 VDC typicalCurrent in Field Power Contact: Max. 10A

IsolationSystem Power to I/O Driver: Optical isolation

Environmental LimitsOperating Temperature: -20 to 60°C, 5 to 90%RHStorage Temperature: -45 to 85°CVibration: IEC-68-2-6, 2G in operation

Regulatory ApprovalsEMC: CE EN-55082, EN-55081Safety: UL 508

WeightNet Weight: 150 g

Ordering Information

NA-4000 Series M-1000/2000/3000/4000/6000 Series M-7000 Series

Step 1: Select a Network Adaptor Module Step 2: Select I/O Modules Step 3: Select Power Modules (optional)

NA-4010: Ethernet Network Adaptor (Modbus/TCP)

*The NA-4010 Ethernet Network Adaptor is expandable with up to 32 I/O modules. Please refer to pages 5-31 to 5-44 to select the M-series modules that you need for your own application.

The certifi cation logos shown here apply to some or all of the products in this section. Please see the Specifi cations section or Moxa’s website for details.

Page 3: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-30

RS-485 or RS-232 network adaptor modules

www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-30

5

Rem

ote I/O >

NA-4020/4021

NA-4020/4021

Specifi cationsSerial CommunicationBaudrate: 1200 to 115200 bpsData Bits: 7, 8Parity Bits: None, Even, OddStop Bits: 1, 2Signals:NA-4020: Data+, Data-, Gnd, DIRNA-4021: TxD, RxD, Gnd

Software FeaturesProtocols: Modbus/RTU, Modbus/ASCIIModbus Address: 00 to 99 by rotary switchesUtility: ioAdminProgramming Library: MXIO DLL library for Windows supporting Visual Basic, Visual C++, Borland C++ BuilderNumber of I/O Modules: Max. of 32 I/O expansion modules

Ordering Information

0 1

2 3

4 5

6 7

CH0

CH0

CH0 CH0

ioLogik 4000Modbus RS-485NA-4020

SYSTxDRxDI/O

FieldPower

0 1

2 3

4 5

6 7

SG

Field Power (0 VDC)Field Power (24 VDC)

SG

24V 0V

0V 0V

24V 24V

System Power (0 VDC)

System Power (24 VDC)

Field Power (0 VDC)

Field Power (24 VDC)

Shielding Ground

System Power (5 VDC)System Power (GND)

System Bus

Non-isolationSwitchingPower

NA-4000 Series M-1000/2000/3000/4000/6000 Series M-7000 Series

Step 1: Select a Network Adaptor Module Step 2: Select I/O Modules Step 3: Select Power Modules (optional)

NA-4020: RS-485 Network Adaptor (Modbus)

NA-4021: RS-232 Network Adaptor (Modbus)

*The NA-4020/4021 RS-485/RS-232 Adaptors are expandable with up to 32 I/O modules. Please refer to pages 5-31 to 5-34 to select the M-series modules that you need for your own application.

Power RequirementsPower Input: 11 to 28.8 VDC, 24 VDC typicalPower Consumption: 70 mA typical @ 24 VDCCurrent for I/O Modules: Max. 1.5A @ 5 VDC

Field PowerRated Voltage: 11 to 28.8 VDC, 24 VDC typicalCurrent in Field Power Contact: Max. 10A

IsolationSystem Power to I/O Driver: Optical isolation

Environmental LimitsOperating Temperature: -20 to 60°C, 5 to 90%RHStorage Temperature: -45 to 85°CVibration: IEC-68-2-6, 2G in operation

Regulatory ApprovalsEMC: CE EN-55082, EN-55081Safety: UL 508

WeightNet Weight: 150 g

The certifi cation logos shown here apply to some or all of the products in this section. Please see the Specifi cations section or Moxa’s website for details.

Page 4: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

emai l : [email protected] www.moxa.com 5-5-31

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-31

5

Rem

ote I/O >

Digital Input M

odules

M-1800 8 digital inputs, sink, 24 VDCInputs per Module: 8 points, sink typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 msCommon Type: External commonPower Consumption: Max. 35 mA @ 5 VDC

M-1401 4 digital inputs, source, 24 VDCInputs per Module: 4 points, source typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 msCommon Type: 4 points/2 COMPower Consumption: Max. 35 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

24V 24V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-1400

Status

0

1

23

M-1400 4 digital inputs, sink, 24 VDCInputs per Module: 4 points, sink typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 msCommon Type: 4 points/2 COMPower Consumption: Max. 35 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

24V 24V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-1401

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

CH4 CH5

CH6 CH7

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power (24 VDC)Field Power (0 VDC)

M-1800

Status

0

1

23

4

5

6

7

Digital Input Modules4 or 8-channel 24 VDC digital input modules4 or 8-channel 24 VDC digital input modules

M-1801 8 digital inputs, source, 24 VDCInputs per Module: 8 points, source typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ 1.5 ms

Common Type: External commonPower Consumption: Max. 35 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

CH4 CH5

CH6 CH7

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power (24 VDC)Field Power (0 VDC)

M-1801

Status

0

1

23

4

5

6

7

Page 5: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-32 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-32

5

Rem

ote I/O >

Digital Input M

odules

M-1411 4 digital inputs, source, 48 VDCInputs per Module: 4 points, source typeOn-state Voltage: 48 VDC nominal, min. 34 VDC to max. 60 VDCMin. Off-state Voltage: Max. 10 VDCOn-state Current: Max. 4 mA / point @ 48 VDCInput Impedance: Typ. 12K ohmsCommon Type: 4 points/2 COMPower Consumption: Max. 35 mA @ 5 VDC

M-1410 4 digital inputs, sink, 48 VDCInputs per Module: 4 points, sink typeOn-state Voltage: 48 VDC nominal, min. 34 VDC to max. 60 VDCMin. Off-state Voltage: Max. 10 VDCOn-state Current: Max. 4 mA / point @ 48 VDCInput Impedance: Typ. 12K ohmsCommon Type: 4 points/2 COMPower Consumption: Max. 35 mA @ 5 VDC

16-channel 24 VDC digital input modules

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

48V 48V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (48 VDC)

* Field Power distributor required.

M-1410

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

48V 48V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (48 VDC)

* Field Power distributor required.

M-1411

Status

0

1

23

M-1600 16 digital inputs, sink, 24 VDC Inputs per Module: 16 points, sink typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 msCommon Type: 16 points/2 COM Power Consumption: Max. 40 mA @ 5 VDC

M-1601 16 digital inputs, source, 24 VDCInputs per Module: 16 points, source typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 ms

Common Type: 16 points/2 COM Power Consumption: Max. 40 mA @ 5 VDC

24V24V

0V0V

1514

1312

1110

98

76

54

32

1Ch0

0 1

18 19

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-1600

Status

3 71115

2 61014

1 5 9 13

0 4 8 12

24V24V

0V0V

1514

1312

1110

98

76

54

32

1Ch0

0 1

18 19

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-1601

Status

3 71115

2 61014

1 5 9 13

0 4 8 12

4-channel 48 VDC digital input modules

Page 6: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

emai l : [email protected] www.moxa.com 5-5-33

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-33

5

Rem

ote I/O >

Digital Input M

odules

4-channel 110/220 VAC digital input modules

M-1451 4 digital inputs, 220 VACInputs per Module: 4 pointsOn-state Voltage: 240 VAC nominal, min. 170 VAC to max. 264 VACMin. Off-state Voltage: Max. 45 VACOn-state Current: Max. 12 mA / point @ 264 VACInput Impedance: Typ. 22K ohmsCommon Type: 4 points/2 COM (single common)Power Consumption: Max. 35 mA @ 5 VDC

M-1450 4 digital inputs, 110 VACInputs per Module: 4 pointsOn-state Voltage: 120 VAC nominal, min. 85 VAC to max. 132 VACMin. Off-state Voltage: Max. 45 VACOn-state Current: Max. 8 mA / point @ 132 VACInput Impedance: Typ. 11K ohmsCommon Type: 4 points/2 COM (single common)Power Consumption: Max. 35 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

N N

L L

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (110 VAC N)Field Power (110 VAC L)

* Field Power distributor required.

M-1450

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

N N

L L

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (220 VAC N)Field Power (220 VAC L)

* Field Power distributor required.

Field Power (220 VAC)

M-1451

Status

0

1

23

Ordering Information

Digital Input Modules

Specs

Model M-1400 M-1401 M-1410 M-1411 M-1800 M-1801 M-1600 M-1601 M-1450 M-1451

Channels 4 4 4 4 8 8 16 16 4 4

Sink/Source Sink Source Sink Source Sink Source Sink Source – –

Connector RTB RTB RTB RTB RTB RTB 20-pin 20-pin RTB RTB

Voltage 24 VDC 24 VDC 48 VDC 48 VDC 24 VDC 24 VDC 24 VDC 24 VDC 110 VAC 220 VAC

Isolation Optical isolation

Page 7: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-34 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-34

5

Rem

ote I/O >

Digital O

utput Modules

M-2400 4 digital outputs, sink, 24 VDC, 0.5AOutputs per Module: 4 points, sink typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 4 points /4 COM (single common)Power consumption: Max. 45 mA @ 5 VDC

Digital Output Modules

4 or 8-channel 24 VDC digital output modules4 or 8-channel 24 VDC digital output modules

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

24V

24V 24V

0 1

2 3

24V

M-2400

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0V 0V

M-2401

Status

0

1

23

M-2401 4 digital outputs, source, 24 VDC, 0.5AOutputs per Module: 4 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 4 points/4 COM (single common)Power Consumption: Max. 45 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

CH4 CH5

CH6 CH7

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power (24 VDC)Field Power (0 VDC)

L

L

L

L

M-2800

Status

0

1

23

4

5

6

7

M-2800 8 digital outputs, sink, 24 VDC, 0.5AOutputs per Module: 8 points, sink typeOutput Voltage Range: 24 VDC nominal, min.11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 8 points/External common (single common)Power Consumption: Max. 60 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

CH4 CH5

CH6 CH7

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power (24 VDC)Field Power (0 VDC)

L

L

L

L

M-2801

Status

0

1

23

4

5

6

7

M-2801 8 digital outputs, source, 24 VDC, 0.5AOutputs per Module: 8 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 8 points/external common (single common)Power Consumption: Max. 60 mA @ 5 VDC

Page 8: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

emai l : [email protected] www.moxa.com 5-5-35

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-35

5

Rem

ote I/O >

Digital O

utput Modules

M-2403 4 digital outputs, diagnostics, source, 24 VDC, 0.5AOutputs per Module: 4 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 4 points /4 COM (single common)Self Diagnostics: YesPower Consumption: Max. 45 mA @ 5 VDC

M-2402 4 digital outputs, diagnostics, sink, 24 VDC, 0.5AOutputs per Module: 4 points, sink typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 4 points/4 COM (single common)Self Diagnostics: YesPower Consumption: Max. 45 mA @ 5 VDC

4-channel digital output modules with diagnostics

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

24V

24V 24V

0 1

2 3

24V

M-2402

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0V 0V

M-2403

Status

0

1

23

M-2405 4 digital outputs, diagnostics, source, 24 VDC, 2AOutputs per Module: 4 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 2A per channel Common Type: 4 points/4 COM (single common)Self Diagnostics: YesPower Consumption: Max. 45 mA @ 5 VDC

M-2404 4 digital outputs, diagnostics, sink, 24 VDC, 2AOutputs per Module: 4 points, sink typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff leakage Current: Max. 50 µAOutput Current Rating: Max. 2A per channel Common Type: 4 points/4 COM (single common)

Self Diagnostics: YesPower Consumption: Max. 45 mA @ 5 VDC

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

24V

24V 24V

0 1

2 3

24V

M-2404

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0V 0V

M-2405

Status

0

1

23

Page 9: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-36 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-36

5

Rem

ote I/O >

Digital O

utput Modules

M-2600 16 digital outputs, sink, 24 VDC, 0.3AOutputs per Module: 16 points, sink typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.3A per channel

Max. 4A per commonCommon Type: 16 points / 2 COM (single common)Power Consumption: Max. 80 mA @ 5 VDC

16-channel digital output modules

24V24V

0V0V

1514

1312

1110

98

76

54

32

1Ch0

0 1

18 19

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

LLLLLL

M-2600

Status

3 71115

2 61014

1 5 9 13

0 4 8 12

24V24V

0V0V

1514

1312

1110

98

76

54

32

1Ch0

0 1

18 19

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

LLLLLL

M-2601

Status

7111561014

1 5 9 13

0 4 8 12

M-2601 16 digital outputs, source, 24 VDC, 0.3AOutputs per Module: 16 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.3A per channel

Max. 4A per common

Common Type: 16 points / 2 COM (single common)Power Consumption: Max. 80 mA @ 5 VDC

Page 10: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

emai l : [email protected] www.moxa.com 5-5-37

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-37

5

Rem

ote I/O >

Digital O

utput Modules

0 1

2 3

4 5

6 7

CH0 CH1

Ch0 Ch1

L1 L1

L2 L2

0 1

2 3

System Power (5 VDC) System Power (GND)

System Bus

Field Power (N or 0 VDC) Field Power (230 VAC or 24 VDC)

* Field power distributor required when the field power is not 24 VDC.

L

L

COM (to N or 0 VDC)

M-2250

Status

0

1

0 1

2 3

4 5

6 7

CH0 CH1

NC NC

N N

L L

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (110 VAC N)Field Power (110 VAC L)

* Field Power distributor required when the field power is not 24 VDC.

L

L

to 125 VAC

M-2254

Status

0

1

NC: No Connection

2-channel relay output module

M-2254 2 digital outputs, Triac, 12 to 125 VAC, 0.5AOutputs per Module: 2 pointsSwitch Type: Zero crossingRated Load Voltage: 15 to 132 VACOutput Current Rating: 0.05 to 0.5AFrequency Range: 47 to 63 HzSurge Current: 40A (16 ms) /4A (30S)On-state Voltage Drop: 1.3 Vrms (max. load)Off-state Leakage Current: Max. 1.5 mACommon Type: 2 points / 2 COMPower Consumption: Max. 35 mA @ 5 VDC

M-2250 2 digital outputs, relay, 24 VDC/230 VAC, 2AOutputs per Module: 2 points, relay Relay Type: Form A, Normally Open (N.O.) Single Pole, Single Throw (SPST)Output Voltage Range: Load dependent 5 to 28.8 VDC / 2A resistive 48 VDC / 0.8A resistive 110 VAC / 0.3A resistive 250 VAC / 2A resistiveMin. Load: 100 µA, 100 m VDC per pointMax. On-state Voltage Drop: 0.5V @ 2A, resistive load, 24 VDCOff-state Leakage Current: Max. 1.5 mACommon Type: 1 point/1 COMPower Consumption: Max. 65 mA @ 5 VDC

Ordering Information

Digital Output Modules

Specs

Model M-2400 M-2401 M-2800 M-2801 M-2600 M-2601 M-2402 M-2403 M-2404 M-2405 M-2250 M-2254

Channels 4 4 8 8 16 16 4 4 4 4 2 2

Sink/Source Sink Source Sink Source Sink Source Sink Source Sink Source Relay Triac

Connector RTB RTB RTB RTB 20-pin 20-pin RTB RTB RTB RTB RTB RTB

Voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 230 VAC/ 24 VDC

12 to 125 VDC

Current 0.5A 0.5A 0.5A 0.5A 0.3A 0.3A 0.5A 0.5A 2.0A 2.0A 2.0A 0.5A

Isolation Optical isolation

Diagnostics – – – – – – Yes Yes Yes Yes – –

Page 11: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-38 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-38

5

Rem

ote I/O >

Analog Input Modules M-3410 4 analog inputs, 0 to 10V, 12 bits

M-3412 4 analog inputs, -10 to 10V, 12 bitsM-3414 4 analog inputs, 0 to 5V, 12 bitsInput SpecificationsResolution in Ranges: 12 bits, 2.44 mV/bit (M-3410) 12 bits, 4.88 mV/bit (M-3412) 12 bits, 1.22 mV/bit (M-3414)Input Current Range: 0 to 10 VDC (M-3410) -10 to 10 VDC (M-3412) 0 to 5 VDC (M-3414)Data Format: 16-bit integer (2’s complement)Accuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°CInput Impedance: 500K ohmsConversion Time: 4 ms / all channels

General SpecificationsPower Consumption: Max. 150 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

M-3400 4 analog inputs, 0 to 20 mA, 12 bitsM-3402 4 analog inputs, 4 to 20 mA, 12 bitsInput SpecificationsResolution in Ranges: 12 bits, 4.88 µA/bit (M-3400) 12 bits, 3.91 µA/bit (M-3402)Input Current Range: 0 to 20 mA (M-3400) 4 to 20 mA (M-3402)Data Format: 16-bit integer (2’s complement)Accuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°CInput Impedance: 120 ohmsConversion Time: 4 ms / all channels

General SpecificationsPower Consumption: Max. 150 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

Analog Input Modules

4-channel analog input modules, 12-bit resolution4-channel analog input modules, 12-bit resolution

4-channel analog input modules, 12-bit resolution Power (GND)System Bus

Field Power (0 VDC) Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

G

CG CG

0 1

2 3

G

Voltage 0 to 10V (M-3410/3411) Voltage -10 to 10V (M-3412/3413) Voltage 0 to 5V (M-3414/3415)

Shielding Ground

M-34xx

Status

0

1

23

4-channel analog input modules, 12-bit resolution Power (5 VDC)

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

G

CG CG

0 1

2 3

G

Current 0 to 20mA (M-3400/3401)

Shielding Ground

Current 4 to 20mA (M-3402/3403)

M-34xx

Status

0

1

23

Page 12: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

emai l : [email protected] www.moxa.com 5-5-39

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-39

5

Rem

ote I/O >

Analog Input Modules

M-3411 4 analog inputs, 0 to 10V, 14 bitsM-3413 4 analog inputs, -10 to 10V, 14 bitsM-3415 4 analog inputs, 0 to 5V, 14 bitsInput SpecificationsResolution in Ranges: 14 bits, 0.61 mV/bit (M-3411) 14 bits, 1.22 mV/bit (M-3413) 14 bits, 0.31 mV/bit (M-3415)Input Current Range: 0 to 10 VDC (M-3411) -10 to 10 VDC (M-3413) 0 to 5 VDC (M-3415)Data Format: 16-bit integer (2’s complement)Accuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°CInput Impedance: 500K ohmsConversion Time: 4 ms / all channels

General SpecificationsPower Consumption: Max. 150 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

M-3401 4 analog inputs, 0 to 20 mA, 14 bitsM-3403 4 analog inputs, 4 to 20 mA, 14 bitsInput SpecificationsResolution in Ranges: 14 bits, 1.22 µA/bit (M-3401) 14 bits, 0.98 µA/bit (M-3403)Input Current Range: 0 to 20 mA (M-3401) 4-20 mA (M-3403)Data Format: 16-bit integer (2’s complement)Accuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°CInput Impedance: 120 ohmsConversion Time: 4 msec. / all channels

General SpecificationsPower Consumption: Max. 150 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

4-channel analog input channels, 14-bit resolution

4-channel analog input modules, 12-bit resolution Power (GND)System Bus

Field Power (0 VDC) Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

G

CG CG

0 1

2 3

G

Voltage 0 to 10V (M-3410/3411) Voltage -10 to 10V (M-3412/3413) Voltage 0 to 5V (M-3414/3415)

Shielding Ground

M-34xx

Status

0

1

23

4-channel analog input modules, 12-bit resolution Power (5 VDC)

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

G

CG CG

0 1

2 3

G

Current 0 to 20mA (M-3400/3401)

Shielding Ground

Current 4 to 20mA (M-3402/3403)

M-34xx

Status

0

1

23

Page 13: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-40 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-40

5

Rem

ote I/O >

Temperature Input M

odules

Temperature Input Modules

2-channel temperature input modules, RTD or thermocouple input2-channel temperature input modules, RTD or thermocouple input

M-6200 2 analog inputs, RTD: PT100, JPT100Input SpecificationsSensor Types: PT50, PT100, PT200, PT500, PT1000, JPT100, JPT200, JPT500, JPT1000, NI100, NI200, NI500, NI1000, NI120, CU10, Resistance 100 milli-ohm/bit, Resistance 10 milli-ohm/bit, Resistance 20 milli-ohm/bitData Format: 16-bit integer (2’s complement)Resolution: 0.1°C / 10 milli-ohmAccuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°CInput Impedance: 500K ohmsConversion Time: 200 ms / all channelsDiagnostics: Range over (if range over, data=Dx8000)

General SpecificationsPower Consumption: Max. 80 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

CH0 CH1

G

CG CG

0 1

2 3

G

RTD

Shielding Ground

CH1-A

CH1-B

M-6200

Status

0

1

M-6201 2 analog inputs, thermocoupleInput SpecificationsSensor Types: Type J/K/T/E/R/S/B/N/L/U/C/D mV input 10 µV/bit, 2 µV/bitData Format: 16-bit integer (2’s compliment)Resolution: 0.1°C / 10uVAccuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°CInput Impedance: 500K ohmsConversion time: 200 ms / all channelsDiagnostics: Range over (if range over, data=Dx8000)

General SpecificationsPower Consumption: Max. 80 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

CH0 CH1

G

CG CG

0 1

2 3

G

Voltage 0 to 10V

Shielding Ground

CH1+

CH1-

Thermocouple

M-6201

Status

0

1

Ordering Information

Analog Input Modules

Specs

Model M-3400 M-3402 M-3410 M-3412 M-3414 M-3401 M-3403 M-3411 M-3413 M-3415 M-6200 M-6201

Channels 4 4 4 4 4 4 4 4 4 4 2 2

Current 0 to 20 mA 4 to 20 mA – – – 0 to 20 mA 4 to 20 mA – – – – –

Voltage – – 0 to 10V -10 to 10V 0 to 5V – – 0 to 10V -10 to 10V 0 to 5V – –

Connector RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB

Resolution 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit – –

Isolation Optical isolation

SensorInput – – – – – – – – – – RTD

(Ohm)

Thermo-couple(µV)

Page 14: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

emai l : [email protected] www.moxa.com 5-5-41

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-41

5

Rem

ote I/O >

Analog Output M

odules

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

NC NC

G

CG CG

0 1

2 3

G

Voltage 0 to 10V (M-4210)Voltage -10 to 10V (M-4211)Voltage 0 to 5V (M-4212)

Shielding Ground

R > 5K Ohm

M-421x

Status

0

1

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

NC NC

G

CG CG

0 1

2 3

G

Current 0 to 20mA (M-4201)Current 4 to 20mA (M-4202)

Shielding Ground

R<500 Ohm

M-420x

Status

0

1

M-4210 2 analog outputs, 0 to 10V, 12 bitsM-4211 2 analog outputs, -10 to 10V, 12 bitsM-4212 2 analog outputs, 0 to 5V, 12 bitsInput SpecificationsResolution in Ranges: 12 bits, 2.44 mV/bit (M-4210) 12 bits, 4.88 mV/bit (M-4211) 12 bits, 1.22 mV/bit (M-4212)Output Current Range: 0 to 10 VDC (M-4210) -10 to 10 VDC (M-4211) 0 to 5 VDC (M-4212)Data Format: 16-bit integer (2’s complement)Accuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°COutput Impedance: Min. 5K ohmsConversion Time: 2 ms / all channelPower Consumption: Max. 200 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

M-4201 2 analog outputs, 0 to 20 mA, 12 bitsM-4202 2 analog outputs, 4 to 20 mA, 12 bitsOutput SpecificationsResolution in Ranges: 12 bits, 4.88 µA/bit (M-4201) 12 bits, 3.91 µA/bit (M-4202)Output Current Range: 0 to 20 mA (M-4201) 4 to 20 mA (M-4202)Data Format: 16-bit integer (2’s complement)Accuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°COutput Impedance: Max. 500 ohmsConversion Time: 2 ms / all channelsPower Consumption: Max. 65 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

Analog Output Modules

2-channel analog input modules, 12-bit resolution

Ordering Information

Analog Output Modules

Specs

Model M-4201 M-4202 M-4210 M-4211 M-4212

Channels 2 2 2 2 2

Current 0 to 20 mA 4 to 20 mA – – –

Voltage – – 0 to 10V -10 to 10V 0 to 5V

Resolution 12-bit 12-bit 12-bit 12-bit 12-bit

Connector RTB RTB RTB RTB RTB

Isolation 1K VDC galvanic isolation

Page 15: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-42 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-42

5

Rem

ote I/O >

Power M

odules

...................

150 mA150 mA

150 mA150 mA

150 mA150 mA

150 mA150 mA

200 mA Supports 1000 mA200 mA

200 mA200 mA

200 mA

Total: 1400 mA Total: 1000 mA

200 mASupports 1000 mA

Supports 1000 mA

0V 24V

24 VDC

0V 48V

48 VDC

0V110 VAC

110 VAC

...................

8-ch , 0 VDC

M-1801 M-7804 M-1800 M-7805

8-ch , 24 VDC

Power ModulesPower expansion and fi eld power or potential distribution

Power expansion module

The system power expansion module is designed to provide extra power for connected I/O expansion modules. Each network adaptor can provide 1.4A @ 5 VDC. If you require more power for your

installed I/O expansion modules, you will need to use an M-7001 module. However, please note that the M-7001 can only provide 1A @ 5 VDC.

Field power distributor module

The field power distributor modules are designed to isolate different field voltages. For example, before you connect a 48 VDC or 110 VAC

DI/O module to a 24 VDC DI/O module, you will need an M-7002 field power module.

Potential distributor module

There are three types of potential distributor modules that provide extra wiring points, such as shielding ground, 0V field power, and 24V field power. For example, the 8-channel digital input (sink type) module

by itself does not have a 24V wiring point. You may add an M-7805 for easier wiring.

Page 16: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

emai l : [email protected] www.moxa.com 5-5-43

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-43

5

Rem

ote I/O >

Power M

odules

M-7001 System power module M-7002 Field power module

0 1

2 3

4 5

6 7

24V 0V

CG CG

0V 0V

24V 24V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power Input (0 VDC)

Field Power Input (24 VDC)

System Power Input (24 VDC)

System Power Input (0 VDC)

Non-isolationSwitchingPower

Shield Ground

M-7001

0 1

2 3

4 5

6 7

CG CG

N N

P P

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (N)Field Power (P)

Shield Ground

Field Power Input (N)

Field Power Input (P)

*Field Power contact disconnected

*Field Power ranging from 24/48 VDC to 110/220 VAC

M-7002

System Input Voltage:• 24 VDC, 11 to 28.8 VDCField Power Input Voltage:• 24 VDC (±20%)System Bus Output Voltage:• 5 VDC (Max.)Field Power Contacts Current:• 10A (Max.)

Field Power Input Voltage: • DC: 5 VDC, 24 VDC, 48 VDCAC: 110 VAC, 220 VACCurrent for Field Power Contacts:• 10A (Max.)

M-7803 Shield signal M-7804 0 VDC M-7805 24 VDC M-7806 24/0 VDC

0 1

2 3

4 5

6 7

CG CG

CG CG

CG CG

CG CG

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (N)Field Power (P)

M-7803

0 1

2 3

4 5

6 7

0V 0V

0V 0V

0V 0V

0V 0V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-7804

0 1

2 3

4 5

6 7

24V 24V

24V 24V

24V 24V

24V 24V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-7805

0 1

2 3

4 5

6 7

24V 0V

24V 0V

24V 0V

24V 0V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-7806

Channels: 8Mode: Shield Signal

Channels: 8Mode: 0 VDC

Channels: 8Mode: 24 VDC

Channels: 4Mode: 24 VDC or 0 VDC

Ordering Information

Power Modules

Specs

Model M-7001 M-7002 M-7803 M-7804 M-7805 M-7806

Channels 0 0 8 8 8 8

Voltage 24 VDC DC: 5, 24, 48 VDCAC: 110/220 VAC --- 0 V 24 VDC 4 for 0 VDC

4 for 24 VDC

Purpose System power Field power Shield signal Field power Field power Field power

Page 17: Modular Remote I/O Selection Guide - Industrial … 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit ... Modular Remote I/O Selection Guide I/O Modules Power Modules

www.moxa.com emai l : [email protected] 5-5-44 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-44

5

Rem

ote I/O >

Accessories

Accessories

Ordering Information

TB 1600 DIN-rail mounting screw terminal module with 20-pin connector20 pins, one-to-one assignment• Connector pitch: 3.81 mm• DIN-rail mounting type• Dimensions (W x L x H): 77.5 x 67.5 x 51 mm• RoHS compliant•

M-8001-PK Removable terminal blockTerminal block for ioLogik 4000 series• Packaging: 9 pcs in one box•

M-8003-PK Marker with 0 to 9 numbering

M-8004-PK Blank markerMarker for ioLogik 4000 series• Packaging: 100 pcs in one box•

20-pin to 20-pin fl at cableConnecting between TB1600 and ioLogik 4000 series• Length: 50 cm• Number of pins: 20•

TB 1600: DIN-rail mounting screw terminal module with 20-pin connector

20-pin to 20-pin fl at cable: 20P-to-20P fl at cable, 500 mm

M-8001-PK: Removable terminal block, 9 pcs per pack

M-8003-PK: Marker with 0 to 9 numbering, white color, 100 pcs

M-8004-PK: Blank marker, 100 pcs