4
Krowne Metal Corporation 100 Haul Rd. Wayne, NJ 07470 (800) 631-0442 krowne.com 40° 35° 35° 35° 35° 35° 35° 40° D D D D D D D D D D C H C H C H MODULAR BAR DETAIL SPECIFICATIONS

MODULAR BAR DETAIL SPECIFICATIONS€¦ · modular bar detail specifications. royal series 1800 (19") 2100 (21") standard series 1800 ... glass racks, approx. 84 garnish station with

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MODULAR BAR DETAIL SPECIFICATIONS€¦ · modular bar detail specifications. royal series 1800 (19") 2100 (21") standard series 1800 ... glass racks, approx. 84 garnish station with

Krowne Metal Corporation100 Haul Rd. Wayne, NJ 07470(800) 631-0442

krowne.com

40°

35°

35°

35°

35°

35°

35°40°

DD

D D

D

D

DD

DD

C

H

C H

C

H

MODULAR BAR DETAIL SPECIFICATIONS

Page 2: MODULAR BAR DETAIL SPECIFICATIONS€¦ · modular bar detail specifications. royal series 1800 (19") 2100 (21") standard series 1800 ... glass racks, approx. 84 garnish station with

ROYAL SERIES 1800 (19") 2100 (21")

STANDARD SERIES 1800 (18.5") 2100 (21")

100 HAUL ROAD

Where passion meets precision.™

Project

WAYNE, NJ 07470800-631-0442973-872-1129

www.krowne.com

© 2019 Krowne Metal Corporation

24"

512"

48" 24" 4" 8" 30" 12" 8" 12" 12"169"

LED (W) LED (W) LED (W) LED (W)

41"3612"

30"

ELIXER STATION(WHEN SPECIFIED)

DIPPER WELL WITHGLASS RINSER(WHEN SPECIFIED)

CUTTING BOARDHOLDS APP.15 BOTTLES

LED LIGHT

3 BOWL SINK WITH LIQUOR RAIL IN FRONT TO EXTEND FULL LENGTH SINK

TYPICAL GLASS STORAGE CABINET SECTION, HOLDS 3 GLASS RACKS, APPROX. 84 GLASSES (WHEN SPECIFIED)

GARNISH STATION WITH SLIDING COVER WITH LIQUOR RAIL IN FRONT TO EXTEND FULL LENGTH (WHEN SPECIFIED)

ICE BIN DIVIDER

� Phillips head screw driver � Level � Tape measure � Chalk line � Power drill � Shims for leveling � 7/16 ratchet wrench � 7/16 box wrench or adjustable wrench � 1/4” x 7/16 hex head bolts and nuts (used for adjoining modular bar sections to each other).

� #8 Self starting galvanized screws (used for modular front panels & Anchoring to floor).

For proper installation, it is important to have the following tools on hand before starting the installation.

LED Lights, pre-wired with quick connectors, run to single power source with AC adapter - plug into the wall

All Underbar Equipment provided with pedestal design. No exposed legs. Pedestal to be sealed to floor.

Removable Panel

Mylar template to be ordered prior to equipment going into production and is used to locate precise footprint of modular bar equipment. Template is to be sent in sections labeled A thru Z for ease of layout. Template allows for accurate marking of floor drain locations and beer/vent lines along with the added benefit of spatially visualizing your future bar. Mylar sections can be sent in up to 200” in length. Mylar template is optional and incurs an additional charge.

Fasteners are supplied in a plastic bag with your bar die.

Make sure all screws are facing the same direction when adjoining modular sections for maintenance purposes.

Tools Required for Installation

Typical Equipment Schedule Typical Bar Assembly Detail with Bar Die Wall Typical Bar Sections with Bar Die Wall Detail*Offset Bartop 2” w/ 36.5” Die Wall

LED Lights & Outlets

Mylar Template

5.5”

Vent Line Chase

Bar Top & Front Finish by others

Electrical ChaseBeer Chase

Soda Chase

Water Line Chase

Plumbing Chase

24”-26”

41”

41” 30”

9”-10”

17.5”

12”

Flat Wall (Side View) Cabinet (Side View)

24”-26”

24”-26”

17.5”

17.5”

17.5”

12”

12”

12”

41”

41”

9”-10”

9”-10”

30”

30”

30”

Removable Panel

Removable Panel

Removable Panel

Removable Panel

5-1/2”

41”

Bar Sink (Side View)

Floor Drain (Side View)

Ice Bin (Side View)

No. Qty Models DescriptionEquipment Remarks

B00 23 KMB Modular Bar Die System

B100 1 KR18-T12 Underbar Dry Waste

B101 1 KR18-MC12 Underbar Mixology Sink

B102 1 KR18-MD8 Underbar Mixology Sink

B103 1 KR18-ML12 Underbar Liquor Display RS-42; KR-521

B104 1 KR18-30-10 Underbar Ice Chest

B105 1 KR18-ME8 Underbar Ice Chest

B106 1 KR18-4SH Underbar Soda Gun Filler

B107 1 KR18-GSB1 Underbar Glass Rack RS-48

B108 1 KR18-43R Underbar Sink

Models Description

KMB-LK-B Cool Blue LED Light (1.5 Watts Output)

KMB-PS-25 25 Watt Power Supply for up to 10 LED Lights

KMB-PS60 60 Watt Power Supply for up to 25 LED Lights

24"

512"

48" 24" 4" 8" 30" 12" 8" 12" 12"169"

LED (W) LED (W) LED (W) LED (W)

41"3612"

30"

ELIXER STATION(WHEN SPECIFIED)

DIPPER WELL WITHGLASS RINSER(WHEN SPECIFIED)

CUTTING BOARDHOLDS APP.15 BOTTLES

LED LIGHT

3 BOWL SINK WITH LIQUOR RAIL IN FRONT TO EXTEND FULL LENGTH SINK

TYPICAL GLASS STORAGE CABINET SECTION, HOLDS 3 GLASS RACKS, APPROX. 84 GLASSES (WHEN SPECIFIED)

GARNISH STATION WITH SLIDING COVER WITH LIQUOR RAIL IN FRONT TO EXTEND FULL LENGTH (WHEN SPECIFIED)

ICE BIN DIVIDER

TYPICAL BAR DETAIL SPECIFICATION

Page 3: MODULAR BAR DETAIL SPECIFICATIONS€¦ · modular bar detail specifications. royal series 1800 (19") 2100 (21") standard series 1800 ... glass racks, approx. 84 garnish station with

ROYAL SERIES 1800 (19") 2100 (21")

STANDARD SERIES 1800 (18.5") 2100 (21")

100 HAUL ROAD

Where passion meets precision.™

Project

WAYNE, NJ 07470800-631-0442973-872-1129

www.krowne.com

© 2019 Krowne Metal Corporation

All underbar equipment and bar die wall provided by Krowne as specified.

Bar top and millwork panels to be provided by millwork fabricator and installed in the field after bar equipment is set. Food service equipment dealer to coordinate.

Z-clips are attached to the inside of the bar front panel.

Millwork InstallationInstall bar counter and removable front millwork panels. It is very important to have the front panels removable to allow access from the customers side for plumbing, electrical and beverage lines. Front panels use interlocking panels and hidden screws meaning they make accessing the underside of the bar very easy and the screws cannot be seen by customers.

Model KMB-PC Stainless Steel Z-CLIPS

with 3/4” offset (24 PACK)

METHOD A

METHOD B

Metal Z-clips are attached to the inside of the bar front panel. Z-clips (KMB-PC) available for purchase.

Slide panel into channel created by two pieces of wood.

Wood should be 3/4” thick to fit Z-clips

TYPICAL MILLWORK SPECIFICATION

Page 4: MODULAR BAR DETAIL SPECIFICATIONS€¦ · modular bar detail specifications. royal series 1800 (19") 2100 (21") standard series 1800 ... glass racks, approx. 84 garnish station with

ROYAL SERIES 1800 (19") 2100 (21")

STANDARD SERIES 1800 (18.5") 2100 (21")

100 HAUL ROAD

Where passion meets precision.™

Project

WAYNE, NJ 07470800-631-0442973-872-1129

www.krowne.com

© 2019 Krowne Metal Corporation

LED Light Specifications

Wiring Example 12/24/V DC No Dimming

Models 25 Watt Power Supply (KMB-PS-25)60 Watt Power Supply (KMB-PS-60)

Features

No glare, down-angled beamRugged and WaterproofBrushed Nickel Oval BezelIncludes stainless steel pre-punched wall plate, (1) 2” x 4” electrical box

Colors Cool Blue (KMB-LK-B)

+12/24VCommon

Power Supply

General Specifications

Mechanical SpecificationsUtility lines: Dedicated chase locations for hot/cold water supply lines, beverage line conduits, and electrical conduit (behind the underbar equipment) this chase is accessible from the floor and runs the entire length of the bar.

Floor drains: Locate floor drains directly below workboard equipment. The number of floor drains will vary depending on the bar layout and local codes.

Plumbing Specifications

Recommended Spot for LED power supply and switch on diagram:

The master switch location is determined by customer preference but we recommend not placing it near a sink and it must meet local district code. Follow these same guideless for the outlet location.

The transformer should be installed in the back of the mod wall and it must be easily accessible by local district code. We would recommend having it plug into an outlet.

All water service and waste connections can be made from the front of the bar (decorative front panel removed). Local codes dictate installation (by others).

Vent Line Chase

Electrical Line Chase

Beer Line Chase

Soda Line Chase

Hot & Cold Water Line Chase

Drain Line Chase

Structure: Configured to the exact size and shape of underbar equipment, freestanding cabinets and openings, as specified.

Chase: Interior chase runs the entire length of the structure including corners.

Utility SpecificationsA 5-1/2” open zone is furnished behind the equipment to provide room for trunk lines, soda lines, plumbing, electrical, etc. To travel vertically or horizontally within the bar structure. Connections can be made from the front of the bar with panels removed.

Electrical SpecificationsAll electrical requirements such as receptacle to blenders, washers, coolers, soda guns, light, etc. (by others).

Modular Bar Die Specifications

Modular Bar Die Chaseways

Input Voltage 9-30V DC, 9-15V AC

Input Power 1.5 Watts Typ, 2.5 Watts Max

Lumens 17 lms typ @3000 °K

IP Rating IP67

Wiring 6” Twisted 18 AWG

TYPICAL DETAIL SPECIFICATION

AC Adapter (not included) - Plug into building wall receptacle. Receptacle to be controlled by a wall switch. Receptacle and wall switch by electrical contractor.

Modular Bar Die Options

24"

512"

48" 24" 4" 8" 30" 12" 8" 12" 12"169"

LED (W) LED (W) LED (W) LED (W)

41"3612"

30"

ICE BIN DIVIDER

ELIXER STATION

GARNISH STATION WITHSLIDING COVER

DIPPER WELL WITHGLASS RINSER

CUTTING BOARD

HOLDS 3 GLASS RACKSAPPROX 84 GLASSES

HOLDS APP.15 BOTTLES

HOLDS APP.12 BOTTLES

HOLDS APP.11 BOTTLES

LED LIGHT

Built-in Duplex Box provision for receptacle to be supplied and installed by electrician. Refer to engineered spec drawing and food service electrical rough-in drawings for receptacle locations.

Down Acting LED Lights, pre-wired with quick connectors, run to single power source with AC adapter. Plug into the wall receptacle. Receptacle to be controlled by a wall switch. AC Adapter, receptacle and wall switch supplied by electrical contractor