1
( MCS ) DC SERVO AMPLIFIERS MODEL MCS 60 MCS 110 SIZE (A) 1/2 2.5/5 6/12 10/20 1/2 2.5/5 6/12 10/20 CASE PM1 PM1 PM1 PM1 PM1 PM1 PM1 PM1 Nominal Current ( ADC ) 1 2.5 6 10 1 2.5 6 10 Peak Current ( ADC ) x 2 sec. 2 5 12 20 2 5 12 20 FDC: Supply Line Fuse type T ( Time-lag ) 15 A / 250 V Supply ( VDC ) 63 VDC 1 100 VDC 1 1 : Recommended DC power supply STANDARD FEATURES u Driving motor range up to 2.7 Nm (386 oz.-in.) u Ultra compact design u Extremely favorable cost to performance ratio u Extremely suitable for personalization u Extremely simple installation and use u Surface Mount Technology u Panel mount u Single DC power supply u Four LED (Red/Green) operating status signals u Fully protected against: - External short circuit - Over/under voltage - Overtemperature u RD Differential reference control mode u T0 Tachogenerator feedback u Five calibration potentiometers SPECIFICATIONS u Supply voltage range: (MCS 60) = 20 - 82 VDC (MCS 110) = 35 - 130 VDC u Operating frequency:................................................................. 22 KHz u Operating temperature:................................... 0 - 40 °C ( 32 - 104 °F ) u Input reference (differential):.................................................. ± 10 VDC u Motor current monitor:................................... ±7,5 V (At peak current) u Auxiliary output supply for encoder(opt):........... +5 V / 12 V @ 130mA u Enable signals:................................................................. +10 - 30 VDC u Output voltage supply:........................................ +10 V / -10 V @ 4mA OPTIONS u A0 Armature Feedback u E0 Encoder Feedback u IO Demand current (torque mode) u PD PWM + Direct u LS + / - Limit switches COMPLIANT P. N. : D.S. / 10.05.16 / MCS / 06

MODEL MCS 60 MCS 110static.e-xina.com/products/oldx/files... · 2020. 3. 16. · : d.s. / 10.05.16 / mcs / 06 DRIVE TYPE MCS - 060 - 10 / 20 - N - S - 1000 / T0 - RD - LS

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MODEL MCS 60 MCS 110static.e-xina.com/products/oldx/files... · 2020. 3. 16. · : d.s. / 10.05.16 / mcs / 06 DRIVE TYPE MCS - 060 - 10 / 20 - N - S - 1000 / T0 - RD - LS

( MCS )

D C S E R V OA M P L I F I E R S

MODEL MCS 60 MCS 110SIZE (A) 1/2 2.5/5 6/12 10/20 1/2 2.5/5 6/12 10/20

CASE PM1 PM1 PM1 PM1 PM1 PM1 PM1 PM1Nominal Current ( ADC ) 1 2.5 6 10 1 2.5 6 10

Peak Current ( ADC ) x 2 sec. 2 5 12 20 2 5 12 20FDC: Supply Line Fuse

type T ( Time-lag ) 15 A / 250 V

Supply ( VDC ) 63 VDC1 100 VDC1

1 : Recommended DC power supply

Standard FeatureSu Driving motor range up to 2.7 Nm (386 oz.-in.)u Ultra compact designu Extremely favorable cost to performance ratiou Extremely suitable for personalizationu Extremely simple installation and useu Surface Mount Technologyu Panel mountu Single DC power supplyu Four LED (Red/Green) operating status signalsu Fully protected against: - External short circuit - Over/under voltage - Overtemperature u RD Differential reference control modeu T0 Tachogenerator feedbacku Five calibration potentiometers

SpeciFicationSu Supply voltage range: (MCS 60) = 20 - 82 VDC

(MCS 110) = 35 - 130 VDC

u Operating frequency:................................................................. 22 KHzu Operating temperature:................................... 0 - 40 °C ( 32 - 104 °F )u Input reference (differential):.................................................. ± 10 VDC

u Motor current monitor:................................... ±7,5 V (At peak current)u Auxiliary output supply for encoder(opt):........... +5 V / 12 V @ 130mAu Enable signals:................................................................. +10 - 30 VDC

u Output voltage supply:........................................ +10 V / -10 V @ 4mA

optionSu A0 Armature Feedbacku E0 Encoder Feedbacku IO Demand current (torque mode)u PD PWM + Directu LS + / - Limit switches

C O M P L I A N T

P. N. : D.S. / 10.05.16 / MCS / 06

Page 2: MODEL MCS 60 MCS 110static.e-xina.com/products/oldx/files... · 2020. 3. 16. · : d.s. / 10.05.16 / mcs / 06 DRIVE TYPE MCS - 060 - 10 / 20 - N - S - 1000 / T0 - RD - LS

Specifications subject to change without notice. Axor does not assume liabil i ty for errors or inaccuracies. © COPYRIGHT 2016 AXOR IND . All r ights reserved. Printed in Italy 05/2016

P. N. : D.S. / 10.05.16 / MCS / 06

DRIVE TYPE

MCS - 060 - 10 / 20 - N - S - 1000 / T0 - RD - LS

POWER SUPPLY: 060 = 60 VDC, 110 = 110 VDC

PROTECTION:S = StandardT = Tropicalized

CONTROL MODE:RD = Differential reference (std)PD = PWM + Direct (opt)IO = Demand current (torque mode) (opt)

ADDITIONAL FEATURES:LS = +/- Limit switches (opt)

AXORadjustamentidentificationnumberHEATSINK VERSIONS: N = Normal (std)

28.5

1819.5

82

95

64.5

135.

5

127.

5

Weight: 0.35 Kg Dimensions in mm

CASE PM1 ( Panel Mount 1 )

Line filter

SIZE: 01/02 - 2.5/05 - 06/12 - 10/20

FEEDBACK:T0 = Tachogenerator (DC) (std)A0 = Armature (opt)E0 = Encoder (opt)00 = No feedback (for I0 and PD control modes) (opt)