MAGNUM MS4448PAE DUAL INVERTERS WITH 2 CLASSIC 150'S ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF LOADS 120 V Utility Main panel or generator. 120/240VAC Dashed Lines indicate Wiring done by customer System must be grounded per NEC specifications ON OFF ON OFF 50 50 ON OFF ON OFF 30 30 ON OFF ON OFF 30 30 ON OFF ON OFF 50 50 INPUT BREAKER MNEAC30QZD-2P INPUT BREAKER MNEA30-2P OUTPUT BREAKER MNEAC50-2P OUTPUT BREAKER MNEAC50-2P ON LOWER DIN RAIL #8 #8 #8 #8 #8 #8 #8 #8 #8 #8 #8 #8 AC HOT OUT L2 AC HOT IN L2 NEUTRAL GROUND AC HOT OUT L1 AC HOT IN L1 GROUND ON OFF ON OFF ON OFF ON OFF 60 60 NORMAL BYPASS BYPASS BREAKER OUTPUT BREAKER 60 60 #8 #8 #6 #6 #6 #6 #6 #6 #8 #8 #8 #8 #8 #8 #8 MNEMS4448PAED-2CL150 RevA – 12/22/2013 Page 1 Customer should remove this wire if this is a grid connected home or if the AC neutral to ground bond is already made in the electrical system. If you are unsure please consult with your electrician.

MNEMS4448PAED-2CL150 MAGNUM MS4448PAE … Diagram Dual...MAGNUM MS4448PAE DUAL INVERTERS WITH 2 CLASSIC 150'S O N F F O N F F O N F F O N F F O N F O N F O N F O ... BTS Cables, Surge

  • Upload
    hahuong

  • View
    232

  • Download
    4

Embed Size (px)

Citation preview

Page 1: MNEMS4448PAED-2CL150 MAGNUM MS4448PAE … Diagram Dual...MAGNUM MS4448PAE DUAL INVERTERS WITH 2 CLASSIC 150'S O N F F O N F F O N F F O N F F O N F O N F O N F O ... BTS Cables, Surge

MAGNUM MS4448PAE DUAL INVERTERS WITH 2 CLASSIC 150'S

ON

OFF

ON

OFF

ON

OFF

ON

OFF O

N

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

LOADS 120 V

Utility Main panelor generator.

120/240VAC

Dashed Lines indicateWiring done by customer

System must be grounded per NEC specifications

ON

OFF

ON

OFF

5050

ON

OFF

ON

OFF

3030

ON

OFF

ON

OFF

3030

ON

OFF

ON

OFF

5050

INP

UT

BR

EAK

ERM

NEA

C3

0Q

ZD-2

P

INP

UT

BR

EAK

ERM

NEA

30

-2P

OU

TPU

T B

REA

KER

MN

EAC

50

-2P

OU

TPU

T B

REA

KER

MN

EAC

50

-2P

ON

LO

WER

DIN

RA

IL

#8 #8#8#8

#8#8

#8#8

#8

#8

#8

#8

AC HOT OUT L2

AC HOT IN L2

NEUTRAL

GROUND

AC HOT OUT L1

AC HOT IN L1

GROUND

ON

OFF

ON

OFF

ON

OFF

ON

OFF

60 60

NO

RM

AL

BYP

ASS

BYP

ASS

BR

EAK

ER

OU

TPU

T B

REA

KER

60 60

#8

#8

#6

#6

#6 #6#6

#6#8 #8

#8 #8

#8

#8

#8

MNEMS4448PAED-2CL150RevA – 12/22/2013

Page 1

Customer should remove this wire if this is a grid connected home or if the AC neutral to ground bond is already made in the electrical

system. If you are unsure please consult with your electrician.

Page 2: MNEMS4448PAED-2CL150 MAGNUM MS4448PAE … Diagram Dual...MAGNUM MS4448PAE DUAL INVERTERS WITH 2 CLASSIC 150'S O N F F O N F F O N F F O N F F O N F O N F O N F O ... BTS Cables, Surge

175ON

OFF

175ON

OFF

GROUND

PV1 Pos In

BATT PLUS BUS

BATTERY NEGATIVE

GROUND

BATTERY NEGATIVE

BATT PLUS BUS

PV2 Pos In

MASTER SLAVE

70

ON

ON

90

70

ON

ON

90

CLASSIC 150 CLASSIC 150

PV

INP

UT

CH

AR

GE C

ON

TRO

LLER O

UT

CH

AR

GE C

ON

TRO

LLER O

UT

PV

INP

UT

INV

ERTER

MA

IN B

REA

KER

INV

ERTER

MA

IN B

REA

KER

DC Wiring done by MidNite SolarDashed Lines

indicates Field wiring done by Customer

PV Array 1

PV Array 2

48 Volt Customer supplied

battery bank

MNEMS4448PAED-2CL150RevA – 12/22/2013

Page 2

All Midnite installed Battery cables are 2/0.

Customer should use minimum of 4/0 cable to the

battery bank

Page 3: MNEMS4448PAED-2CL150 MAGNUM MS4448PAE … Diagram Dual...MAGNUM MS4448PAE DUAL INVERTERS WITH 2 CLASSIC 150'S O N F F O N F F O N F F O N F F O N F O N F O N F O ... BTS Cables, Surge

Communications cabling, BTS Cables, Surge

Protection ETC

SELECT

TECHAGS METER SETUPSHOREINVERTER

CHARGER

INV

CHG

FAULT

PWR

ON/OFF

ON/OFF

STACK

MAGNUM RTR

NETWORK

GROUND

PV 1 Pos In

BATT PLUS BUS

BATTERY NEGATIVE

GROUND

BATTERY NEGATIVE

BATT PLUS BUS

PV 2 Pos In

MAGNUM BMK

ON

OFF

1A

BTS

MASTER SLAVE

BTS

CLASSIC 150 CLASSIC 150

BM

K B

REA

KER

AC HOT OUT L2

AC HOT OUT L1 NEUTRAL

AC HOT IN L2

AC HOT IN L1

SPD 300

SPD 300

SPD 300

SPD 300

MNEMS4448PAED-2CL150RevA – 12/22/2013

Page 3

Page 4: MNEMS4448PAED-2CL150 MAGNUM MS4448PAE … Diagram Dual...MAGNUM MS4448PAE DUAL INVERTERS WITH 2 CLASSIC 150'S O N F F O N F F O N F F O N F F O N F O N F O N F O ... BTS Cables, Surge

Build Notes

1- Use 2 Classic 150's2- Use 4 SPD300's3- Requires 2 an MNE175STM-240 E-Panels4- Requires MidNite Back Plate5- Use 2 MNEDC90 Breakers for the Battery side 1 for each Classic. 6- Use 2 MNEDC70 Breakers for the PV side 1 for each Classic.7- Put Each Classics breakers in that E-panel above the respective Classic8- Install and wire the Magnum BMK and power it through a MNEPV2 Breaker9- Put PV breaker towards the Top/Front of the E-Panel10-Use MNEDC175s for the battery Main Breakers11- Wire the WBjr to Aux2 Positive in Classic 1 (Left side Classic)12- Make sure to label the PV inputs 1 and 2. Classic 1 is on the left13- Install Follow Me Cables and Classic BTS14- Install Magnum Energy BTS 15- Use #4 wire from Battery Main breaker to the Battery Positive bus bar16- All AC wiring to be #8 except Bypass wiring that is #6. 17- ByPass breakers to be 60 amp 2 pole18- Input Breakers are 30 amp 2 pole, Output breakers are 50 amp 2 pole.19- Make sure to set the Magnum back to factory default battery chemistry.20- Program the classics for Follow-Me, BTS Slave/Master, Nominal Battery voltage etc.21- Follow proper test procedures to confirm Sunny Island and Classic functionality22- Send all Pages to the Customer.

Signed by Builder___________________________________________

Page 4

MNEMS4448PAED-2CL150RevA – 12/22/2013