ResponseONE MODEL 92000 WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com PN: 92000-90 REV: E012319

METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

ResponseONE

MODEL 92000WEATHER TRANSMITTER

METEOROLOGICAL INSTRUMENTS

INSTRUCTIONS

R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USATEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com PN: 92000-90

REV: E012319

Page 2: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

92000-90(E)

Contents

SECTION DESCRIPTION PAGE1.0 INTRODUCTION ................................................................................................................. 1

2.0 SPECIFICATIONS ............................................................................................................... 1

3.0 BEFORE INSTALLATION ................................................................................................... 2

4.0 INSTALLATION ................................................................................................................... 24.1 Placement ............................................................................................................................ 24.2 Mounting and Alignment ...................................................................................................... 24.3 Wiring Connections ............................................................................................................. 3

5.0 OPERATION ....................................................................................................................... 35.1 Serial Output Formats ......................................................................................................... 35.2 SDI-12 Measurement Commands ....................................................................................... 35.3 SDI-12 Non-Measurement Commands ............................................................................... 55.4 Extended Commands .......................................................................................................... 55.5 Low Power Operation .......................................................................................................... 6

6.0 SETTING SERIAL OUTPUTS AND OPERATING PARAMETERS .................................. 66.1 SensorConfigurationwithResponseONE CONFIG program ............................................ 66.2 SensorConfigurationusingaGeneralPurposeCommunicationsProgram ....................... 66.3 Command Overview ............................................................................................................ 66.4 Command Details ................................................................................................................ 7

7.0 EXAMPLE SETTINGS ........................................................................................................ 9

8.0 EMC COMPLIANCE ........................................................................................................... 9

9.0 WARRANTY ........................................................................................................................ 9

10.0 CE COMPLIANCE ............................................................................................................. 9

APPENDIX

A WIRING CONNECTIONS A1: RS-232 Serial Connection........................................................................................ 10 A2: RS-485 / RS-422 Serial Connection - Full Duplex .................................................. 10 A3: RS-485 / RS-422 Serial Connection - Half Duplex...................................................11 A4: RS-485 / RS-422 Serial Connection - Output Only ..................................................11 A5: SDI-12 Serial Connection........................................................................................ 12 A6: RS-485 Serial Connection - Full Duplex (Model 26800 Translator) ........................ 12 A7: TippingBucketRainGauge ....................................................................................... 13

B SENSOR ORIENTATION AND DIMENSIONS ................................................................. 14

C TROUBLESHOOTING ...................................................................................................... 15

OPERATING INSTRUCTIONS

Model 92000 ResponseONE Weather Transmitter

Page 3: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980
Page 4: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 192000-90(E)

MODEL 92000ResponseONEWEATHER TRANSMITTER

2.0 SPECIFICATIONSWIND SPEEDRange: 0-70m/s(156mph)Resolution: 0.01 m/sAccuracy: 0 - 30 m/s ±2% or 0.3 m/s

30 - 70 m/s ±3%

WIND DIRECTIONAzimuthRange: 0-360degreesResolution: 0.1 degreeAccuracy: ± 2 degrees

TEMPERATURERange: -40 - +60°CResolution: 0.1°CAccuracy: ± 0.3°C (-20 - +50°C) ±0.7°C(other)

RELATIVE HUMIDITYRange: 0 - 100%Resolution: 0.1% Accuracy: ± 2% (5 - 95%)

ATMOSPHERIC PRESSURE Range: 500-1100hPaResolution: 0.1hPaAccuracy: ±0.3hPa(0-60°C) ±1hPa(-40-0°C)

COMPASS (For siting orientation only)Range: 0-360 degreesResolution: 0.1 degrees Accuracy: ± 2 degrees

TIPPING BUCKET RAIN GAUGE Connection for external tipping bucket rain gauge is provided (normallyopenmagneticreedswitch)

SERIAL OUTPUT (Selectable)Interface Type: RS-232 or RS-485/422, SDI-12Formats: ASCII Text - polled or continuous

NMEA - continuous SDI-12 - polled

Baud Rates: 1200, 4800, 9600, 19200 and 38400

GENERALOutput rate: 1 Hz typicalPower Supply: 10 - 30 VDC,

7 mA typical, 80 mA maxProtection Class: IP65EMC Compliance: FCC Class A digital device

IEC standard 61326-1Dimensions: 30cmhighx13cmwideWeight: 0.7kg(1.5lb)ShippingWeight: 1.6kg(3.5lb)Operating Temperature: -40 - +60°C

1.0 INTRODUCTIONTheModel92000ResponseONEtmWeatherTransmittermeasuresfourkeymeteorologicalvariableswithonecompactinstrument.Itisidealformanyweathermonitoringapplicationsrequiringaccurate,reliable measurement.

Thesensorfeaturesdurablecorrosion-resistantconstructionthroughout.Anultrasonicwindsensor,atmosphericpressuresensor,temperatureandhumiditysensorsarecarefullyintegratedinto a convenient, streamlined package. Connections are provided for optional tipping bucket rain gauge.

TheResponseONE installsonreadily-available1 inch(IPS)pipe.Wiringconnectionsaremadeinaconvenient,weather-proof junction box; special connectors and custom cables are not needed.

Measured data is output in a serial format. NMEA, SDI-12, and ASCII protocols are available to suit many applications. Continuous serial output or polled operation may be used.

RS-232 or RS-485 serial format option allows direct connection to YOUNGdisplays,marineNMEAsystems,dataloggers,orothercompatible serial devices.

OperatingparametersareeasilyreviewedandchangedusingtheResponseONE CONFIG program provided. All settings are stored internally in non-volatile memory.

Page 5: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 292000-90(E)

3.0 BEFORE INSTALLATION3.0 UNPACKING THE ResponseONETheResponseONEcomesinacustomshippingcarton.CarefullyinspecttheinstrumentwhenfirstunpackingandreportanyvisibledamagetoyourYOUNGsupplier.Besuretoretainthebirdspikesand orientation ring for use.

1

3

2

4

7

5

6

8

1. Ultrasonic wind sensor array2. IntegratedpressureT/RHsensor(insideprotectivefilter)3. Temperature screen4. Junction box / wiring terminals5. Mounting post clamp6. Orientation ring7. Sensor cable (ordered separately)8. Bird spikes

Figure 3.0 ResponseONE Features

TheResponseONE arrives fully calibrated and ready to use. As supplied,thesensorisconfiguredasfollows:

FACTORY DEFAULT CONFIGURATION

Protocol: RS-232 ASCII / RS485 (output only)Baud Rate: 9600Wind Format: PolarWindUnits: m/s,DegreesazimuthTemperature: CelsiusRelative Humidity: Percent RHPressure: hPa

DefaultconnectionsareshowninAPPENDIXA,FIGUREA1.OtheroptionsarealsodescribedinAPPENDIXA.TheseareselectedusingtheResponseONE CONFIG programwhichisavailable at www.youngusa.com. Note: Always connect and bench test a complex system before installation in the field.

4.0 INSTALLATION4.1 PLACEMENTProper instrument placement is important. Eddies from buildings, trees, or other structures can influence measurements. Locatethesensorwellawayfromobstructions.Asageneralrule,airflowaroundastructureisdisturbedto10timestheheightofthestructuredownwindand1-1/2timestheheightofthestructureabovetheroof.

10H

1.5 H

H

OPEN, LEVEL GROUND

Fig 4.1 Wind Siting Considerations

4.2 MOUNTING AND ALIGNMENTTheResponseONEmountsonstandard1-inch(IPS)pipe.Thisiscommonlyavailablesteelpipewithanoutsidediameterof1.34inches(34mm).Thepipeshouldbesecuredvertically.Placetheorientationringoverpipeendwithguidepinfacingup.Donottightenclampsyet.

Most applications require aligning the wind sensor array togeographic north (0 degrees). In this orientation the junction boxfacesSOUTH(180degrees).SeethediagraminAPPENDIXBfordetails.Twomethodsaresuggestedbelow:

4.2.1 ORIENTATION USING KNOWN GEOGRAPHIC DATA (PREFERRED)Obtainaccurategeographicdatafortheinstallationsite,thiscanbeatopographicmap,graphicalGPSmapordetailedroadmap.Usingthetransducersasasightingaid,alignthesensorwitharemotefeaturethat represents the proper orientation.After alignment,tighten the mounting post band clamp to secure theposition.DONOTOVER-TIGHTEN.Engageorientationringpinwithslot(Fig4.2.3)insensorbase(underj-box).Nowtightenthebandclampontheorientationring.IftheResponseONE islaterremoved,theorientationringwillpreservethesensoralignment.

NORTH

Fig4.2.1SightingofWindSensorusingGeographicFeature

Page 6: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 392000-90(E)

4.2.2 ORIENTATION USING BUILT-IN ELECTRONIC COMPASS.

Note: Acclimate the ResponseONE to ambient temperature at the installation site before calibrating.

Place theorientationringover thepipeand temporarilytighten theband clampwith theorientation ring restingapproximately4-6inches(10-15cm)fromthetopofthepipewith theguidepin facingup.PlaceResponseONE sensoronmountingpipe,fullyseatingitonthepipeandallowingforfreerotationofthesensor.ConnectcableasindicatedinAPPENDIXAandapplypowertothesystem.Rotate thesensor1-1/4rotations(CWorCCW). Withjunctionboxcover removed, locateandpressandholdthe“calibrate”buttonfor3seconds;theindicatorlightwillblink rapidly to indicate that calibrationmode is active.Slowlyrotatethesensorintheoppositedirectionfor1-1/4rotations(thiswillalsoservetounwindthecablearoundthemountingpole).Aftercompletingtherotations,pressandholdthe“calibrate”buttonagainfor3seconds;theindicatorwilldoubleblink.Withinthenext60seconds,tightenthemountingpostbandclamptosecurethesensor.DONOTOVER-TIGHTEN.Atthispoint,thecompasswilllockthedirectionofthesensorandtheResponseONE will output correctwinddirectiondata;theindicatorwillblinkoncepersecond.

Loosen the orientation ring band clamp and raise theorientationringupwardonthepipetoallowtheguidepintoinsertintotheslotonthebaseoftheResponseONE. Tightentheorientationringbandclamp.

Todisablethecompass,pressandholdthebuttonforonesecond.Theindictorlightwillnolongerblink.

Important: Be sure to allow for magnetic declination in your measurement. A declination value can be entered usingtheResponseONE CONFIG program or it can be compensatedinthedata-loggerprogram.Pleasenotethatdeclinationmaychangeifthesensorismovedtoanewlocation.

http://www.ngdc.noaa.gov/geomag-web/#declination

CALIBRATEBUTTON ROTATE

1-1/4 TURNS

Fig 4.2.2 Orientation of Wind Sensor Using Electronic Compass

SENSOR CLAMP

INDEX PIN IN NOTCH

ORIENTATION RING

Fig4.2.3ProperEngagementofOrientationRingwithSensor

4.3 WIRING CONNECTIONSTheResponseONEissuppliedwithRS-232,RS-485andSDI-12signalcapability.PleaseselectthesignaltypedesiredandrefertotheappropriateWIRINGCONNECTIONSdiagraminAPPENDIXAforconnectingtheResponseONE to your serial device. Please note, theResponseONEisnotequippedwithanalogoutputs.

4.4 TIPPING BUCKET RAIN GAUGETheResponseONEhasprovisionforconnectinganoptionaltippingbucketraingauge.Whenproperlyconnectedandconfigured,thetotalnumberoftipsisincludedontheserialoutputmessageineitherASCII or SDI-12 output format. See Appendix A for details.

5.0 OPERATION5.1 SERIAL OUTPUT FORMATSTheResponseONEcomesstandardwiththefollowingserialoutputformats:

Format/Protocol Wiring FormatASCII Polled and Continuous RS-232, RS-485

NMEA 0183 v3.0 Automatic RS-232, RS-485

SDI-12 Polled SDI-12

Detailedinformationabouteachprotocolisinthefollowingsection.

IfyouwishtochangesettingsfromthefactorydefaultvaluesshowninSection3,thisiseasilydoneusingtheResponseONE CONFIG program described in Section 6.0.

Page 7: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 492000-90(E)

5.1.1 ASCIIASCII output format provides continuous measurement data in text formatatanyoftheavailablebaudrates.

Thewindmeasurement inASCIIoutputappearseither inPOLAR(default)orCARTESIANUVformat.WithPOLARformat,thewindspeed threshold and wind speed units are user-selectable.WithCARTESIANthewindthreshold is ignoredandwindspeedunitsare always meters per second (m/s).

ASCII POLAR FORMATa www.ww ddd.d ttt.t hhh.h bbbb.b ppppp ss*cc<CR>

where:a = Sensor addresswww.ww = Wind speedddd.d = Wind directionttt.t = Temperaturehhh.h = Relative Humiditybbbb.b = Barometric Pressureppppp = Tipping Bucket (Optional)ss = Status code* = Asterisk (ASCII 42)cc =Checksum<CR> = Carriage return (ASCII 13)

ASCII CARTESIAN (UV) FORMATa uu.uu vv.vv ttt.t hhh.h bbbb.b ppppp ss*cc<CR>

where:a = Sensor address±uu.uu = U-axis wind speed (m/s)±vv.vv = V-axis wind speed (m/s)ttt.t = Temperaturehhh.h = Relative Humiditybbbb.b = Barometric Pressureppppp = Tipping Bucket (Optional)ss = Status code* = Asterisk (ASCII 42)cc =Checksum<CR> = Carriage return (ASCII 13)

CHECKSUM is a two-character hexadecimal value (in printableASCIIformat)generatedbytakingtheexclusive-orofallcharactersuptotheasterisk.STATUSCODEshowsanon-zerovaluewhenthesensorcannotacquiresufficientsamplesorameasurementerrorhasoccurred.SeeAPPENDIXCformoreinformationonstatuscodes.

5.1.2 ASCII POLLEDASCII POLLED is like ASCII format described above except just oneserialoutputstringissentforeachpollingcommandreceived.ThepollingcommandisMa!where'a'isthesensoraddress(validcharacters:0-9,A-Z,a-z).Thedefaultaddressis'0' (ASCII 48).

5.1.3 NMEANMEA format provides continuous measurements in standard NMEAmarinesentencesat4800baud.TheResponseONE must be connectedtoaNMEA-capabledevice.TheNMEAdataiscontainedintwosuccessivedatasentences.Thefirstsentence,“MWV”,containswinddata,whilethesecondsentence,“XDR”,containstemperature,relativehumidityandbarometricpressuredata.SpecificdetailsoftheNMEAdatastringarebelow:

NMEA FORMAT - part 1$WIMWV,ddd,R,www.w,u,A*cc<CR><LF>

where:WI =Devicetype(weatherinstrument)MWV = Wind direction and speedddd = Wind direction (degrees)www.w = Wind speedu = Wind speed units S=mph N = knots K=kmph M = m/sA = Data status code: A=valid, V=invalid* = Asterisk (ASCII 42)cc =Checksum<CR><LF> = Carriage return,Line feed (ASCII 13,10)

NMEA FORMAT - part 2$WIXDR,C,ttt.t,cu,TEMP,H,hhh.h,P,RH,P,bbbb.b,pu,BARO*cc<CR><LF>

where:WI =Devicetype(weatherinstrument)XDR = Type of measurement (transducer)ttt.t = Temperaturecu = Temperature units C = Celsius F=Fahrenheithhh.h =Relativehumiditybbbb.b = Barometric Pressurepu = Barometric Pressure units mB = millibar InHg=InchesofMercury* = Asterisk (ASCII 42)cc =Checksum<CR><LF> = Carriage return,Line feed (ASCII 13,10)

CHECKSUM is the two-character printable hexadecimal valuegeneratedbytakingtheexclusive-orofallcharactersbetween'$' and '*'.

5.2 SDI-12SDI-12 stands for serial data interface at 1200 baud. It is often used to interface battery powered data recorders with microprocessorbaseddevicesdesignedforenvironmentaldataacquisition.SDI-12isusedtypicallywhenlowpowerisaconcern.TheSDI-12devicenormally remains in a low power, standby state until it is polled at whichtimeameasurementissent.SDI-12caneffectivelyaddressmultiplesensorsonthesamecable.

5.2.1 SDI-12 MEASUREMENT COMMANDSModel92000usestheSDI-12(v1.3)serialcommunicationprotocolto initiate measurements and set sensor operation parameters. Thedefaultsensoraddressis0(zero),andcanbechangedtoanyvalidsingle-charactervalueifneeded.AdditionaldetailsabouttheSDI-12protocolmaybefoundatwww.sdi-12.org.

Afterinitialpower-upwith12VDC,thesensorisinalow-powerstandbystatewithaquiescentcurrentof4.2mA.AvalidandproperlyaddressedSDI-12commandwakesthesensortoinitiateameasurement,setorcheckoperatingparameters.Aftercommandprocessinghasfinished,thesensorreturnstothelow-powerstandbystate.

SDI-12 'M' or 'C' commands initiate ameasurement.The sensorresponse message indicates the maximum time needed beforethemeasurement isready,anddatavalueswillbeavailable.Themaximumtimerangesfrom1to5secondsdependingontheSampleCount.

Page 8: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 592000-90(E)

If an 'M' command initiates ameasurement, the sensor sends aServiceRequestwhenthemeasurement isreadytoberetrieved.WhenthepollingdevicereceivestheServiceRequestitthensendsa'D'commandtorequestmeasurementresultsfromthesensor.With'C'commands,noServiceRequestissent,andthepollingdevicemustwaitthefulldelaytimebeforesendingthe'D'commandtorequestthemeasurement.

SDI-12 Measurement commands and responses are listed below.

COMMAND RESPONSE DESCRIPTIONaM! attts<CR><LF> Take a measurementaMC! attts<CR><LF> TakeameasurementwithCRC

checksumaC! atttss<CR><LF> Take a concurrent measurementaCC! atttss<CR><LF> Take a concurrent measurement

withCRCchecksumaD0! a+www.ww+ddd.d+sc<CRC><CR><LF> (Polar) a±uu.uu±vv.vv+sc<CRC><CR><LF> (Cartesian)aD1! a+ttt.t+hhh.h+bbbb.b+sc<CRC><CR><LF> a+ttt.t+hhh.h+bbbb.b+rrrrr+sc<CRC><CR><LF>

where:a = Sensor addressttt = Delay time (seconds)s/ss = Number of samples to collectddd.d = Wind direction (degrees)www.ww = Wind speed (selected units)±uu.uu = U-axis wind speed (m/s)±vv.vv = V-axis wind speed (m/s)+sc =StatusCode(seeAPPENDIXC)ttt.t =Temperature (selected units)hhh.h = Relative Humiditybbbb.b = Barometric Pressure (selected units)rrrrr = Tipping Bucket counter (Optional)<CRC> =CRCchecksum(onlywhererequested)<CR><LF> = Carriage return, line feed (ASCII 13, 10)

WinddataformatdependsonthesensorOutputFormatparametersetting (Polar or Cartesian). Rain gauge tip count is disabled by default. See extended commands to enable it.

5.2.2 SDI-12 NON-MEASUREMENT COMMANDSTheSDI-12protocolincludesstandardcommandsforidentifyingthesensorandchangingitsaddress.

COMMAND RESPONSE DESCRIPTION?! a<CR><LF> Address Querya! a<CR><LF> Acknowledge ActiveaI! a13 YOUNG C092000 vvvnnnnnn<CR><LF>

SendIdentification vvv = Firmware Version nnnnnn = Serial NumberaAb! b<CR><LF> ChangeAddress

a = Sensor address b = New sensor address

aV! a0000<CR><LF> StartVerification

5.2.3 EXTENDED COMMANDSThe SDI-12 command set may be customized with ExtendedCommands to accommodate manufacturer settings and otherfunctions. Extended Commands are listed below. Where tworesponsesareshown,oneisforavalidcommand,theotherisforan invalid (ERR) command.

COMMAND RESPONSE DESCRIPTIONaXB! aXB, OK<CR><LF> Saveparametersettingstoflash.aXFn! aXF, F=n<CR><LF> n = Output Format code.

0 or 1 (Polar or Cartesian) aXF,ERR F=0/1<CR><LF>

aXPn! Parameter report, 4 reports needed for all parameters aXP1,F=f,UW=uw,UT=ut,UP=up,T=t,S=s,W=w<CR><LF> a = Sensor address f = Wind Format uw = Polar wind speed units 1=mph 2=knots 3=km/h 4=m/s ut= Temp units up=Pressure units t=Threshold,polaronly(0-150cm/s) s = Sample count, internal (1-800) w = Wait (seconds)

aXP2,OD=od,OT=ot,OH=oh,OP=op<CR><LF> od=WD Offset ot=Temp Offset oh=RHOffset op=Pressure Offset

aXP3,M=m,RE=re,CE=ce,CD=cd<CR><LF> m=WS multiplier re=Rain Enable ce=Compass Enable cd=Compass Declination aXP4,PWR=VV.V VDC<CR><LF> aXPn,ERR n=1/2/3/4 ONLY<CR><LF>

aXSnnn! nnn = Sample Count (001-800 samples) aXS,S=nnn<CR><LF> aXS,ERR S=001-800 ONLY<CR><LF>

aXMnnnnn! nnnnn=WS multiplier x 10000 (00000 - 30000) aXM,M=nnnnn<CR><LF> aXM,ERR M=00000-30000 ONLY<CR><LF>

aXTnnn! nnn=WindSpeedThreshold(000-150cm/s) aXT,T=nnn<CR><LF> aXT,ERR T=000-150 ONLY<CR><LF>

aXUWn! n = Wind Speed Units (1=mph,2=knots,3=kmph,4=m/s) aXUW,UW=n<CR><LF> aXUW,ERR UW=1/2/3/4 ONLY<CR><LF>

aXUTn! n = Temperature Units (0=C, 1=F) aXUT,UT=n<CR><LF> aXUT,ERR UT=0/1 ONLY<CR><LF>

aXUPn! n=PressureUnits(0=hPa/mBar,1=inHg)aXUP,UP=n<CR><LF>

aXUP,ERR UP=0/1 ONLY<CR><LF>

aXOT±nnn! ±nnn = Temperature Offset x 10 (-100 to 100) aXOT,OT=±nnn<CR><LF>

aXOT,ERR OT=-100 - +100 ONLY<CR><LF>

aXOH±nnn! ±nnn = Humidity Offset x 10 (-100 to 100) aXOH,OH=±nnn<CR><LF>

aXOH,ERR OH=-100 - +100 ONLY<CR><LF>

Page 9: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 692000-90(E)

aXOP±nnnn! ±nnnn = Pressure Offset x10 (-5000 to 5000) aXOP,OP=±nnnn<CR><LF>

aXOP,ERR OP=-5000 - +5000 ONLY<CR><LF>

aXOD±nnnn! ±nnnn = Wind Direction Offset x 10 (-3600 to 3600) aXOD,OP=±nnnn<CR><LF>

aXOD,ERR OD=-3600 - +3600 ONLY<CR><LF>

aXCEn! n = Compass Enable (0=Disable, 1=Enable) aXCE,CE=n<CR><LF>

aXCE,ERR CE=0/1 ONLY<CR><LF>

aXCDnddmm! nddmm=Declination(n=E/W/0,dd=DEG,mm=MIN) aXCD,CD=nddmm<CR><LF>

aXCD,ERR CD=nddmm n=E/W/0, dd=00-90, mm=00-60 ONLY<CR><LF>

aXREn! n = Tipping Bucket Enable. 0 or 1 (Disable or Enable) aXRE,RE=n<CR><LF>

aXRE,ERR RE=0/1 ONLY<CR><LF>

aXRR! Reset Tip Count to 0 aXRR,OK<CR><LF>

IMPORTANT! PARAMETER CHANGES MUST BE STORED IN FLASH MEMORY USING THE aXB! COMMAND OR THEY WILL REVERT TO PREVIOUSLY STORED VALUES AT POWER UP.TheaXB!commandmaybesentafterallchangeshavebeenmade,ornotsentatallifthechangesaretemporary.

SAMPLE COUNT(aXSnnn!)Eachwindmeasurementiscalculatedfromthemedianofmultiplewindsamples.Eachsamplerequiresapowerpulsesomoresamplesconsumemorepower.Thedefault sample countof 16 isagoodbalance of low power consumption and robust performance. If winds above 30 m/s are expected, 100 samples may be more suitable. Windsreachingtheperformancelimitof thesensor(70m/s)mayrequireasettingofupto800samples.

THRESHOLD(aXTnnn!)Thresholdsetstheminimumwindspeedneededbeforeanewpolarwinddirectioniscalculated.Thedefaultvalueis25cm/s(0.25m/s).Agreater-than-zerothresholdcanhelpprovidemoremeaningfulscalarwinddirectionaverages.The threshold forCartesian (UV)outputformatisautomaticallyzeroregardlessofthissetting.

5.3 LOW POWER OPERATIONAveragecurrentconsumptionwithdefaultsettingsisabout7.5mA.Thisconfigurationusesminimalpowerandenablesallfeatureseventhoughtheymaynotbeused.Thisissuitableformanylowpowerapplications.

Toreducecurrentconsumptionfurther,additionalstrategiesincludedisabling unused outputs, using polled serial operation, increasing theoutput interval,and limiting thesamplecount to theminimumoptimal number. Faster baud rates also reduce power by limiting transmit duration.

6.0 SETTING OUTPUTS AND OPERATING PARAMETERS

6.1 SENSOR CONFIGURATION WITH ResponseONE CONFIG PROGRAM (RECOMMENDED)

TheYOUNGResponseONE CONFIGprogramisavailablefromthefactorywebsite:www.youngusa.com.Itprovidesaneasymethodforcheckingandconfiguringsensoroperation.InstalltheprogramonaWindows7orhigherPCand follow instructions thatappearontheprogramscreentoretrievecurrentsensorsettingsorsendnew settings.

6.1.1 Opening the ProgramAfterinstallingtheprogramonyourPC,clickthedesktopicontoopentheprogram.Thefollowingscreenshouldappear:

Fig 6.1 ResponseONE CONFIG program opening screen

If you are using theResponseONE for the first time, the defaultsettingswillappear.Forreferencetheseare:

FACTORY DEFAULT CONFIGURATION

Protocol: RS-232 ASCII / RS-485 (output only)Baud Rate: 9600Wind Format: PolarWindUnits: m/s,DegreesazimuthTemperature: CelsiusRelative Humidity: Percent RHPressure: hPa

If these settings are correct for your application, then you mayproceedwithoperationof thedevice. If youwish tochangeanysettings, available options can be selected from menu items visible. After changes are made, the ResponseONE CONFIG program automaticallysavesthenewsettingsinflashmemory

6.2 SENSOR CONFIGURATION USING A GENERAL PURPOSE COMMUNICATIONS PROGRAM

A general purpose text-based serial communications program like HyperTerminalmaybeusedtomanuallyconfigurethesensorbysendingsimpletextcommands.Thefollowingguidelinesapply:

TheYOUNGsensorandcommunicationprogrammustoperateatthe same baud rate and be properly connected. Sensor RS-232modemustbeenabled.SeetheRS-232wiringdiagram,FIGUREA1,inAPPENDIXA.

Factory default sensor baud rate is 9600, Configure the serialcommunicationsprogramforNOhandshakingand1start,8data,1stopbit,noparity,noflowcontrol.

ThesensormustbeinCOMMANDMODEinordertosetparameters.EnterCOMMANDMODEbysendingthreeESCcharacters(ASCII27)inquicksuccessionwhilethesensorisrunning.WhenthesensorisinCOMMANDMODE,itsendsa'>'promptcharacterindicatingthatitisreadytoacceptcommands.

If the prompt does not appear after sending three indicatingcharacters, re-checkwiringandcommunicationprogramsetup. Ifthesensorbaudrateisunknown,trysendingtheESCcharactersateachofthefiveavailablebaudrates(1200,4800,9600,19200and38400).It isalsopossiblethatsensorparametershavebeenpurposelyconfiguredtodisableRS-232mode.Ifthisisthecase,thefollowingmethodmustbeused.

Page 10: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 792000-90(E)

Inordertoprovideaccessunderallconditions,thesensoralwaysbeginsoperationatpowerupwithserialcommunicationssetto38400baud and RS-232 connections enabled. Immediately after power up, thereisashorttimewindowinwhichtosendtheESCcharactersand enter COMMAND MODE.

Tousethisfeature,setyourserialcommunicationprogrambaudrateto38400.Removepowerthenwait5seconds.Re-applypowertothesensor.Thesensorwilltransmitfourasterisksimmediatelyafterpowerup.After theasterisksappear,sendthreeESCcharacters.The COMMANDMODE '>' prompt should appear. To do thisusing ResponseONE CONFIG,connecttheResponseONE to your computer,open theprogram(makesure thecorrectserialport isselected),thengotothe'COMMANDS'menuandselect'ACQUIREResponseONE'.

Awindowwillcomeuptellingyouthattheserialportwillbesetto38400baud.Click'OK'tocontinue.ThensimplyapplypowertotheResponseONEandtheprogramwillconnectautomatically.

6.3 COMMAND OVERVIEWAfterthe'>'promptappears,send'??' to display a list of available commands. Send 'RPTV'toreportcurrentsettings.(Notethatsomevaluesinthereportareforfactorysettingsandcannotbechangedbytheuser.)

Commandsarecasesensitiveandtheexactformatmustbeused.Forexample,theSET01nncommandrequirestwodigitsfortheserialformat code. If you send SET014 instead of SET0104thesensorwillrejectthecommandandindicateanerror.Endallcommandswithacarriagereturn(ASCII13).InHyperTerminal,dothisbypressingtheENTERkey.

After receiving the carriage return, the sensor will evaluate thecommand. Valid commands will be executed. Current settings can be evaluated at any time by sending RPTV to get a new report.

IMPORTANT NOTE:TheYOUNGResponseONE CONFIG program automatically savesallsettingstoflashmemorywhentheyaresenttothesensor.SettingsthatarechangedmanuallymustbesavedtoflashwiththeSET77command.

COMMAND DESCRIPTIONSET01nn Set output modeSET02n Set output formatSET03nn Set baud rateSET04n Set wind speed unitsSET05a Set sensor addressSET06nnn SetwindspeedthresholdSET07nnnnn Set wind speed multiplierSET08±nnnn Set direction offsetSET09dd Set damping factorSET10nnnn Set output intervalSET12nnn Set sample countSET13n Set wind output formatSET14n Set temperature unitsSET15n Set pressure unitsSET16±nnn Set temperature offsetSET17±nnn SetrelativehumidityoffsetSET18±nnnn Set pressure offsetSET25n Turn compass on/offSET26nddmm Set compass declinationSET27 Set tipping bucket count to 0SET28n Enable tipping bucketSET77 Save settingsXX OperatemodeRPTV Report current settings?? Display command listHELP Display command list

6.4 COMMAND DETAILS COMMAND DESCRIPTIONSET01nn Enable RS-232 and RS-485 output modes.

Default value is 04.Where nn=04 Enable RS-232 08 Enable RS-485 output only 16 EnableRS-485halfduplex 24 Enable RS-485 full duplexUsage example:>SET0104 Enables RS-232 only.

SET02n Settheserialoutputformat.Defaultvalueis2.Where n= 2 ASCII 3 ASCII POLLED 4 NMEA 5 SDI-12Usage example:>SET022 Sets output to ASCII continuous. Note: If SDI-12

is selected, save settings (SET77)thenpowermust be cycled off, then on again to operateproperly. SDI-12 automatically sets baud rate to 1200 and disables RS-232 and RS-485.

SET03nn Set the baud rate for RS-232/RS-485 serialcommunication. Default value is 96. Note:Baud ratemustbe thesameasdeviceconnected to it.

Where nn=12 1200 baud 48 4800 baud 96 9600 baud 19 19200 baud 38 38400 baudUsage example:>SET0338 Sets baud rate to 38400.

SET04n Set wind speed units (ASCII, ASCII POLLED, NMEA and SDI-12). Default value is 4.

Where n= 1 mph 2 knots 3 mph 4 m/sUsage example:>SET044 Sets wind speed to m/s.

SET05a Set sensor address for ASCII POLLED and SDI-12.Note:Thisistheaddresswhenpollingwiththe“aM!”command(SDI-12)and‘Ma!’command(ASCIIPolled)where'a'istheaddress. Default value is 0.

Where a= 0-9,A-Z,ora-zUsage example:>SET052 Sets polling address to number 2.

SET06nnn Setthewindspeedthreshold.Minimizeserraticwind direction indications at very low wind speeds.Inpolarmode,thisallowsthesensoroutput tomimicamechanicalwind vane thatretains its orientation when there is no wind.Default value is 25.

Where nnn= 000-150 cm/sUsage example:>SET06025 Setswindspeedthresholdto25cm/s.

SET07nnnnn Set wind speed multiplier. Value is x10000. All windspeedmeasurementsaremultipliedbythisparameter. Default value is 10000 for a multiplier of 1.0000.

Where nnnnn= 00000-30000Usage example:>SET0709909 Sets multiplier to 0.9909>SET0710023 Sets multiplier to 1.0023

Page 11: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 892000-90(E)

SET08±nnnn Set wind direction offset. Value is degrees x10 and may be positive or negative. Wind direction is always re-scaled to a 0-360 range after offset is applied. Default value is 00000.

Where ±nnnn= -3600 to +3600Usage example:>SET08-0012 Offsets wind direction reading by -1.2 degrees>SET08+0005 Offsets wind direction reading by +0.5 degrees

SET09dd Set damping factor.Default value is 00.Thismeans no damping is applied.High dampingvaluesatlongoutputintervalscanslowtherateatwhichindicatedwindvalueschange.Windmeasurement outputs are damped using thefollowing formula: Sdamped = [(dd-1) * Sdamped + Ssample] / dd

Where dd= Damping factor (00-99) Sdamped = New or last damped wind speed Ssample = New wind speed

Usage example:>SET0905 Sets damping factor to 5 (Note: Damping

factor only applies to wind reading.)

SET10nnnn Set output interval. Sets the time intervalbetween measurements in one millisecond increments. Lower values increase power consumptionwhencontinuousmeasurementsare taken. Default is 1000.

Where nnnn= 0000-9999Usage example:>SET101000 Sets output interval to 1000 milliseconds

(1 second) (Note: If output interval is set toolow,theResponseONE will automatically calculatetheminimumoutputinterval.)

SET12nnn Setsamplecount.Therateatwhichthesensorinternally takes complete sonic wind samples is greater than 200 times per second. Thiscommandsetsthenumberofinternalsamplesused to calculate the median measurementresult. Default is 16.

Where nnn= 000-800Usage example:>SET12016 Sets sample count to 16.

More internal samples consume more power whileprovidinggreaterimmunitytoconditionsliketurbulenthigh-speedwind.Fewersamplesconsume less power while providing lessimmunitytodisruptiveconditions.ThiscommandinteractswiththeOUTPUTINTERVALsetting.More samples may require a longer outputinterval.

SET13n SetASCIIoutputformat.DetermineswhetherASCII and ASCII POLLED serial outputs provide winddataineitherPolar(speedanddirection)or Cartesian (UV) form. Default is Polar.

Where n= 0 Polar 1 Cartesian (UV)Usage example:>SET130 Sets output format to polar.

SET14n Set units of temperature to Celsius or Fahrenheit.DefaultisCelsius.

Where n= 0 Celsius 1 FahrenheitUsage example:>SET140 Sets temperature units to Celsius.

SET15n Set units of pressure to hPa or inHg.DefaultishPa.

Where n= 0 hPa 1 inHgUsage example:>SET150 SetspressureunitstohPa.

SET16±nnn Set temperature offset. Value is x10. Default is 0.

Where ±nnn= -100 to +100Usage example:>SET16-012 Sets temperature offset to -1.2

SET17±nnn Set relative humidity offset. Value is x10.Default is 0.

Where ±nnn= -100 to +100Usage example:>SET17+008 Setshumidityoffsetto+0.8

SET18±nnnn Set barometric pressure offset. Value is x10. Default is 0.

Where ±nnnn= -5000 to +5000Usage example:>SET18+1234 Sets pressure offset to +123.4

SET25n Turn compass on or off. Default is 0.Where n= 0 Off 1 OnUsage example:>SET251 Turnscompasson.Note:Thiscommandshould

onlybeusedifthesensorhasbeencalibratedatcurrent location. Calibration automatically turns on compass.

SET26nddmm Set compass (magnet ic) decl inat ion. Magnet i c dec l i na t ion i s the ang lebetween magnetic north and true north.

Where n= E, W, or 0 (East, West, or none) dd= 00 to 90 degrees mm= 00 to 60 minutes Accurate declination data for your location can

be obtained at: http://www.ngdc.noaa.gov/geomag-web/#declination

Usage example:>SET26W0606 SetdeclinationtoWest6°6’(zipcode49686)

SET27 Settippingbucketcounttozero.Themaximumtipping bucket count is 65535. Tipping bucket count automatically rolls over to zero once 65535 maximum count is reached (65535 + 1 = 0).

SET28n Enabletippingbucketoutput.(Note:thisisanoptional configuration which requires a j-boxboardwithtippingbucketinput).Defaultvalueis0.

Where n= 0 Disable tipping bucket 1 Enable tipping bucketUsage example:>SET281 Enable tipping bucket count output.

SET77 Save all settings to non-volatile memory. Any settings which have not been saved will belost when power is removed. Saved settingsare loaded at power up. This commandmaybeusedanytimethesensorisinCOMMANDMODE. Note: ResponseONE CONFIG program automatically sends this commandwhen <Send Parameters> button is pressed.

XX ReturnsthesensortoOPERATEMODERPTV Report current settings?? Display command listHELP Display command list

Page 12: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 992000-90(E)

7.0 EXAMPLE SETTINGSSuggestedsettings.Notallpossiblesettingcombinationsareshown.TheResponseONE CONFIGprogramisrecommendedforchangingsetup parameters. See wiring diagrams for jumper settings.

7.1 FACTORY DEFAULT RS-232: Enabled RS-485 (output only): Enabled Serial Output Format: ASCII Output Interval: 1000 Sample Count: 16

7.2 MINIMUM POWER RS-232: Enabled RS-485: Disabled Serial Output Format: ASCII Output Interval: 1000 Sample Count: 16

7.3 HIGH WINDS Output Delay: 1000 Sample Count: 200

AVERAGE CURRENT DRAW

Output FormatOutput Interval

Sample Count

Baud Rate (bps)

Average Current Draw

(mA)5 minutes 16 1200 4.35 minutes 200 1200 4.41 second 16 9600 7.41 second 200 38400 29.4

ASCII Polled 5 minutes 16 9600 7.21 second 16 4800 7.21 second 50 4800 11.6

Table Typical current draw per output format.

NMEA

ASCII

SDI-12 (polled)

8.0 EMC COMPLIANCEThis device complies with Part 15 of the FCC Rules. Operationissubject to the following twoconditions: (1) thisdevicemaynotcause harmful interference, and (2) this devicemust accept anyinterference received, including interference that may causeundesired operation.

This equipment has been tested and found to comply with thelimits foraClassAdigitaldevice,pursuant topart15of theFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful interferencewhentheequipment isoperated inacommercial environment. This equipment generates, uses, andcan radiate radio frequencyenergyand, ifnot installedandusedin accordance with the instruction manual, may cause harmfulinterferencetoradiocommunications.Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterferenceathisownexpense.

ThisISMdevicecomplieswithCanadianICES-001.Cet appareil ISM est conforme à Ia norme NMB-001 du Canada.

EN55011/CISPR11,Group1,ClassBdevice.ClassBequipment issuitable foruse indomesticestablishmentsand in establishments directly connected to a low voltage powersupply network which supplies buildings used for domesticpurposes.

9.0 WARRANTYThis product iswarranted to be free of defects inmaterials andconstructionforaperiodof12monthsfromdateofinitialpurchase.Liabilityislimitedtorepairorreplacementofthedefectiveitem.AcopyofthewarrantypolicymaybeobtainedfromR.M.YoungCompany.

10.0 CE COMPLIANCEThis product has been tested and complies with European CErequirementsfortheEMCDirective.Pleasenotethatshieldedcable must be used.

Page 13: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 1092000-90(E)

SETTINGSOutput Mode: RS-232Output Format: ASCII, ASCII POLLED, or NMEABaud Rate: 1200, 4800, 9600, 19200 or 38400

Set connected device baud rate to match ResponseONE.1 start bit, 8 data bits, no parity, 1 stop bit, no flow control.

Use shielded cable. Connect cable shield to earth ground as shown.(Color code is for Young 18446 cable)

Figure A1: RS-232 SERIAL CONNECTION

Serial Device

SDIZBA

TXRX

P2JUMPERZ.SDI

Y

TX.B

RX.A

REF

+PWR

-PWR

EARTH GND

WHTGRNBRNREDBLK

Earth Ground

(+)(-)

Supply Voltage 10-30 VDC80mA max

5 3 2

Typical DB-9RS-232 Connection

Z.SDI

Y

TX.B

RX.A

REF

+PWR

-PWR

EARTH GND

WHTBLUGRNORGBRNREDBLK

Earth Ground

(+)(-)

Supply Voltage 10-30 VDC80mA max

Sensor TX (Z Inverted signal)Sensor TX (Y Non-inverted signal)

Sensor RX (B Inverted signal)Sensor RX (A Non-inverted signal)

Signal Reference

SDIZBA

TXRX

P2

JUMPERP2JUMPER

SETTINGSOutput Mode: RS-485 Full DuplexOutput Format: ASCII, ASCII POLLED, or NMEABaud Rate: 1200, 4800, 9600, 19200 or 38400

Set serial device baud rate to match ResponseONE.1 start bit, 8 data bits, no parity, 1 stop bit, no flow control.

Use shielded cable. Connect cable shield to earth ground as shown.(Color code is for Young 18660 Cable)

Figure A2: RS-485 / RS-422 SERIAL CONNECTION - FULL DUPLEX

Serial Device

92000

RESPONSE ONE

APPENDIX A: WIRING CONNECTIONS

Page 14: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 1192000-90(E)

Z.SDI

Y

TX.B

RX.A

REF

+PWR

-PWR

EARTH GND

WHTGRN

BRNREDBLK

Earth Ground

(+)(-)

Supply Voltage 10-30 VDC80mA max

Sensor TX/RX (Inverted signal)Sensor TX/RX (Non-inverted signal)

Signal Reference

SDIZBA

TXRX

P2

JUMPERP2JUMPER

SETTINGSOutput Mode: RS-485 Half DuplexOutput Format: ASCII, ASCII POLLED, or NMEABaud Rate: 1200, 4800, 9600, 19200 or 38400

Set serial device baud rate to match ResponseONE.1 start bit, 8 data bits, no parity, 1 stop bit, no flow control.

Use shielded cable. Connect cable shield to earth ground as shown.(Color code is for Young 18446 Cable)

Figure A3: RS-485 / RS-422 SERIAL CONNECTION - HALF DUPLEX

Serial Device

SETTINGSOutput Mode: RS-485 Output OnlyOutput Format: ASCII, or NMEABaud Rate: 1200, 4800, 9600, 19200 or 38400

Set serial device baud rate to match ResponseONE.1 start bit, 8 data bits, no parity, 1 stop bit, no flow control.

Use shielded cable. Connect cable shield to earth ground as shown.(Color code is for Young 18446 Cable)

Figure A4: RS-485 / RS-422 SERIAL CONNECTION - OUTPUT ONLY

Serial Device

SDIZBA

TXRX

P2JUMPERZ.SDI

Y

TX.B

RX.A

REF

+PWR

-PWR

EARTH GND

WHTGRN

BRNREDBLK

Earth Ground

(+)(-)

Supply Voltage 10-30 VDC80mA max

Sensor TX (Z Inverted signal)Sensor TX (Y Non-inverted signal)

Signal Reference

92000

RESPONSE ONE

92000

RESPONSE ONE

APPENDIX A: WIRING CONNECTIONS

Page 15: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 1292000-90(E)

Z.SDIY

TX.BRX.AREF

+PWR-PWR

EARTH GND

WHTBLUGRNORGBRNREDBLK

P2

JUMPER

SDIZBA

TXRX

P2JUMPEREarth

Ground

SensorTX ZTX YRX BRX A

SIG Ref

Figure A6: RS-485 SERIAL CONNECTION - FULL DUPLEX

Model 26800Translator

SETTINGSOutput Mode: RS-485 Full DuplexOutput Format: ASCII, ASCII POLLED, or NMEABaud Rate: 1200, 4800, 9600, 19200 or 38400

Set 26800 Translator baud rate to match ResponseONE.

Use shielded cable. Connect cable shield to earth ground as shown.(Color code is for Young 18660 cable)

Earth Ground

GRN

BRNREDBLK

To SDI-12 Data Recorder

To SDI-12 Data RecorderSupply Voltage 10-30 VDC ( + )

(80 mA Max) ( - )

Use shielded cable.Connect cable shield to earth ground as shown.

Figure A5: SDI-12 SERIAL CONNECTION

SDI-12Serial Device

SDIZBA

TXRX

P2JUMPER

APPENDIX A: WIRING CONNECTIONS

SHIELD

Z.SDIY

TX.BRX.AREF

+PWR-PWR

EARTH GND

Page 16: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 1392000-90(E)

SETTINGSOutput Mode: RS-232, RS-485Output Format: ASCII, ASCII POLLED, or SDI-12Baud Rate: 1200, 4800, 9600, 19200 or 38400

Command: SET27 Set tipping bucket count to zero SET28n n = 0 Disable Count n = 1 Enable Count

Use 2 conductor cable. (Color code is for Young 18641 cable)

SENSOR SIGNALCABLE

A B

2 CONDUCTOR CABLEYOUNG 18641

CABLE FITTINGINSERT

APPENDIX A: WIRING CONNECTIONS

Figure A7: TIPPING BUCKET RAIN GAUGE

SETTINGSOutput Mode: RS-232, RS-485Output Format: ASCII, ASCII POLLED, or SDI-12Baud Rate: 1200, 4800, 9600, 19200 or 38400

Command: SET27 Set tipping bucket count to zero SET28n n = 0 Disable Count

n = 1 Enable Count

Use 2 conductor cable. (Color code is for Young 18641 cable)

(52202, 52203, OR EQUIVALENT)

Page 17: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 1492000-90(E)

135 mm

26 mm

283 mm

MOUNTINGPIPE

INSERTION80 mm

ORIENTATIONRING

N

W E

SJUNCTION

BOX

270° 90°

180°

POLAR

(WIND SPEED, WIND DIRECTION)

EXAMPLE:

"WIND AT 45° " 0°

Example: 45°

+V m/s"WIND FROM NORTH"

CARTESIAN

(U, V)

+U m/s"WIND FROM EAST"

APPENDIX B: SENSOR ORIENTATION AND DIMENSIONS

Page 18: METEOROLOGICAL INSTRUMENTS...WEATHER TRANSMITTER METEOROLOGICAL INSTRUMENTS INSTRUCTIONS R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980

Page 1592000-90(E)

APPENDIX C: TROUBLESHOOTING

Problem SolutionNo Output • Checkinputvoltageatsensor(10–30VDC).

• Checkwiringconnections.• Verifyserialsettings(baudrate,1stopbit,8databits,noparity,noflowcontrol).• ‘Acquire’thesensorwiththeResponseONE CONFIG program (see section 6.2)

and verify setup mode.

One-way communication

• Checkwiringconnections.• ‘Acquire’thesensorwiththeResponseONE CONFIG program (see section 6.2).• ChangeoutputmodetoRS-485fullorhalfduplex,orRS-232.

Status codes otherthan00

appear

• Statuscodesother than00 (or ‘A’ inNMEAmode)mean there isanerror.See‘StatusCodes’sectionfordetails.

No response to poll command

• Checkpowersupply.• Checkwiringconnections.• Verifyserialsettings(baudrate,1stopbit,8databits,noparity,noflowcontrol).• Verifysensoraddress(ifthesensor’saddressis‘0’,thenthepollcommandis‘0M!’inSDI-12modeand'M0!inASCIIPolledmode.).

• ‘Acquire’thesensorwiththeResponseONE CONFIG program (see section 6.2) and verify setup mode.

Direction is incorrect

• Ifcompassisoff,makesurejunctionboxisfacingsouth.• ‘Acquire’ the sensor with the ResponseONE CONFIG program (see section

6.2) and verify settings. Enable and calibrate compass if needed, enter compass declination,andsetthewinddirectionoffset(defaultis0000).

• Turn compass on and calibrate if needed. Tipping Bucket

input not counting

• Checkwiring.• Verify tipping bucket count output is enabled.• Verifyproperoperationofthetippingbucket.

StatuscodesforASCIIoutputarehexvaluesaddedtogetherbeforeoutput(astatuscodeof0Cwouldbeacodeof08and04).NMEAonlyallowsfor‘acceptable’or‘void’data.

Status Code Meaning00 Valid data01 TransducerpathAblockedordirty,clearblockageandcleantransducers02 TransducerpathBblockedordirty,clearblockageandcleantransducers04 TransducerpathCblockedordirty,clearblockageandcleantransducers08 Temperature/Relative Humidity ErrorA NMEA data acceptable (NMEA wind data only)V NMEA data void (NMEA wind data only)