MC-6 Cabinet / Work Center Assembly Instructions

Inspection Notice: Shipping damage is the responsibility of the freight company. Please inspect the cabinet for any visible signs of damage and notify the freight company immediately.

1. Remove the packing material from the cabinet and lift the cabinet from its shipping skid.

Warning! To avoid injury, please have someone else assist you in lifting or moving the cabinet and any equipment you plan to place on top of the cabinet.

2. Open the doors and remove the accessory box, located inside the cabinet.

3. Attach the Rollers The rollers and mounting screws are located inside the accessories box. Carefully place the cabinet onto its back. A carpeted surface or a piece of cardboard should

be used, beneath the cabinet, to protect the cabinets finish.

There are four rollers (casters). Two of the rollers are locking rollers. For easier access; we suggest that the locking rollers be placed at the front of the cabinet, as shown below.

Each roller is secured with a single Philips head screw, provided.

Page 2: MC6-Cabinet Assembly Instructions - Rena USA Assembly Instructions Rev. 9-16-05 2 4. Feeder Shelf Attachment Information The feeder shelf and mounting screws …

MC6-Cabinet Assembly Instructions Rev. 9-16-05 2

4. Feeder Shelf Attachment Information The feeder shelf and mounting screws are located inside the accessories box.

The feeder shelf and safety plate may be mounted to the left or right side of the cabinet and the height of the feeder shelf is adjustable. Please be sure to choose the appropriate side of the cabinet and proper mounting holes (shown below).

Please refer to the following chart for your specific system. SYSTEM Shelf

Mounting Side See Step # for

Details Envelope Imager III Printer and AF500 Feeder Left 6

XPS-80/90 Printer and AF500 Feeder Right 7 UT-361 Dual Tabber and AF500 Feeder Right 8

Page 3: MC6-Cabinet Assembly Instructions - Rena USA Assembly Instructions Rev. 9-16-05 2 4. Feeder Shelf Attachment Information The feeder shelf and mounting screws …

MC6-Cabinet Assembly Instructions Rev. 9-16-05 3

5. Safety Plate Attachment and Cabinet Height Adjustment Procedure

The safety plate and mounting screws are located inside the accessories box.

Position and attach the safety plate to the appropriate side of the cabinet. See chart below. Lightly secure the safety plate at its highest position.

Cabinet Height Adjustment: Raise the cabinet to the desired height, using the four adjustable feet, as shown below.

Loosen the two screws and lower the safety plate until it rests on the floor, then tighten the screws securely.

Warning! If this step is not followed, the cabinet could tip if a feeder is placed on the cabinet by itself.

Please refer to the following chart for your specific system. SYSTEM Safety Plate

Mounting Side See Step # for

Details Envelope Imager III Printer and AF500 Feeder Left 6

XPS-80/90 Printer and AF500 Feeder Right 7 UT-361 Dual Tabber and AF500 Feeder Right 8

Page 4: MC6-Cabinet Assembly Instructions - Rena USA Assembly Instructions Rev. 9-16-05 2 4. Feeder Shelf Attachment Information The feeder shelf and mounting screws …

MC6-Cabinet Assembly Instructions Rev. 9-16-05 4

6. For use with the Envelope Imager III Printer and AF500 Feeder Carefully place the cabinet onto its right side and attach the feeder shelf and safety plate to the

left side, as shown below.

After properly securing the feeder shelf, place the cabinet back onto its rollers.

Adjust cabinet to the desired height and then lower the safety plate to the floor. Secure the safety plate using the two screws. See step 5 for instructions on attaching the safety plate and adjusting the height of the cabinet.

The cabinet is now ready for use. For safety reasons, place the Envelope Imager III onto the cabinet first, then place the feeder onto the cabinet.

A screw must be installed into all 6 holes (3 holes on each side).

Page 5: MC6-Cabinet Assembly Instructions - Rena USA Assembly Instructions Rev. 9-16-05 2 4. Feeder Shelf Attachment Information The feeder shelf and mounting screws …

MC6-Cabinet Assembly Instructions Rev. 9-16-05 5

7. For use with the XPS-80/90 Printer and AF500 Feeder

Carefully place the cabinet onto its left side and attach the feeder shelf and safety plate to the right side, as shown below. See Step 4 for details on attaching the feeder shelf.

After securing the feeder shelf, place the cabinet back onto its rollers.

Adjust cabinet to the desired height and then lower the safety plate to the floor. Secure the safety plate using the two screws. See Step 5 for instructions on attaching the safety plate and adjusting the height of the cabinet.

The cabinet is now ready for use. For safety reasons; place the XPS-80/90 onto the cabinet first, then place the feeder onto the cabinet.

Page 6: MC6-Cabinet Assembly Instructions - Rena USA Assembly Instructions Rev. 9-16-05 2 4. Feeder Shelf Attachment Information The feeder shelf and mounting screws …

MC6-Cabinet Assembly Instructions Rev. 9-16-05 6

8. For use with the UT-361 Dual Tabber and AF500 Feeder Carefully place the cabinet onto its left side and attach the feeder shelf and safety plate to the

left side, as shown below. See Step 4 for details on attaching the feeder shelf.

After securing the feeder shelf, place the cabinet back onto its rollers.

Adjust cabinet to the desired height and then lower the safety plate to the floor. Secure the safety plate using the two screws. See Step 5 for instructions on attaching the safety plate and adjusting the height of the cabinet.

The cabinet is now ready for use.

For safety reasons; place the UT-361 onto the cabinet first, then place the feeder onto the cabinet.

A TB399 conveyor, with only one leg attached, can be used at the exit end of the UT361, as

shown above.