Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

www.pce-industrial-needs.com

Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 [email protected] http://www.industrial-needs.com/

Manual Sound level meter

PCE DSA 50

Page 2: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

2

Manual ..................................................................................................................................... 1 Sound level meter .................................................................................................................... 1 PCE DSA 50 ............................................................................................................................ 1 1. FEATURES OF THE INSTRUMENT ................................................................................... 4

1.1. Accessories .................................................................................................................................. 4 1.2. Weatherproof accessories set for microphone ............................................................................. 5 1.3. System configuration ................................................................................................................... 6 1.4. Measured quantities ..................................................................................................................... 7 1.4.1. Sound level meter (SLM) mode ............................................................................................... 7 1.4.2. 1/1-octave analyzer mode ........................................................................................................ 7 1.4.3. 1/3-octave analyzer mode ........................................................................................................ 8 1.4.4. Infra G filter mode ................................................................................................................... 8 1.5. Specifications ............................................................................................................................... 8 1.5.1. Specifications for SLM mode ............................................................................................ 12 1.5.2 1/1-octave analyzer mode ........................................................................................................ 14 1.5.2. 1/3-octave analyzer mode .................................................................................................. 16 1.5.3. Infra G filter mode ............................................................................................................. 20 1.6. Influence of operating environment ........................................................................................... 21 1.7. Influence of instrument accessories ........................................................................................... 21

2. CONTROLLING OF THE INSTRUMENT ......................................................................... 24 2.1. Control keys ............................................................................................................................... 24 2.2. Input and output connectors of the instrument ........................................................................... 25 2.3. Default instrument settings .................................................................................................... 27 2.4. Preparation of the instrument to operation ................................................................................. 27

3 . OPERATION .............................................................................................................. 28 3.1. Instrument data plate .................................................................................................................. 28 3.2. SETUP menu ............................................................................................................................. 29 3.3. RESULTS menu ........................................................................................................................ 30 3.3.1. SLM mode ............................................................................................................................. 31 3.3.2. 1/1-octave analyzer ................................................................................................................ 32 3.3.3. 1/3-octave analyzer mode ...................................................................................................... 33 3.3.4. Infra G filter mode ................................................................................................................. 34 3.4. SETUP TIME menu ................................................................................................................... 35 3.5. FILTER menu ............................................................................................................................ 36 3.6. MEMORY menu ....................................................................................................................... 37 3.6.1. Save measure ......................................................................................................................... 37 3.6.2. Load measure ......................................................................................................................... 38 3.6.3. Measurement history .............................................................................................................. 38 3.6.3.1. SLM mode ........................................................................................................................... 39 3.6.3.2. 1/1-octave analyzer mode .................................................................................................... 40 3.6.3.3. 1/3-octave analyzer mode .................................................................................................... 41 3.6.3.4. Infra G filter mode ............................................................................................................... 41 3.6.4. FREE/OCCUPIED menu ....................................................................................................... 42 3.7. CLEAR menu ............................................................................................................................ 42 3.7.1. Measure in memory ............................................................................................................... 43 3.7.2. Measurement history .............................................................................................................. 43 3.7.3. Entire memory ....................................................................................................................... 44

4 . COMMUNICATION WITH COMPUTER ............................................................. 44 5.1. Recommendations for correct performing of measurements ..................................................... 45

Page 3: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

3

5.2. Internal battery ........................................................................................................................... 45 5.3. Calibration of the instrument ..................................................................................................... 45 5.4. Warranty .................................................................................................................................... 46 5.4.1. Complaint instructions for the purchaser: .............................................................................. 46 5.5. Maintenance and repair .............................................................................................................. 47

6. CE MARKING AND CONFORMANCE TO EU COUNCIL DIRECTIVES ....................... 47 Appendix A. Filter characteristics ...................................................................................... 47 Appendix B. Directional responses ................................................................................... 51 Appendix C. Sensitivity to vibration ................................................................................... 53

Page 4: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

4

1. FEATURES OF THE INSTRUMENT Digital sound analyzer model DSA-50 is the instrument combining the features of integrating sound level meter as well as 1/1- and 1/3-octave band frequency analyzer. The majority of quantities characterizing occupational, environmental and other kinds of acoustic noise can be measured by this Class 1 digital-signal-processing instrument. DSA-50 is designed to be capable to perform long-lasting measurements without need of battery recharging. Internal battery allows for at least 24h continuous operation of the instrument provided microphone heating is turned off. External battery or mains adaptor may be also used. The instrument is equipped with USB 1.1 interface to enable bi-directional communication with PC.

1.1. Accessories Basic accessories: Model 5014 external power supply (Mascot). Instruction Manual. Declaration of Conformity. Warranty Card. Certificate of Verification. OP 1/2 microphone windscreen. Carrying case. 1.8 m USB interface cable. DSA-50 computer software for instrument remote operation (PC under MS Windows 98SE/ME/2000/XP required).

Page 5: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

5

DSA Monitor computer software for data display, readout and analysis (PC under MS Windows 98SE/ME/2000/XP required). Additional accessories: Built-in microphone heating system. Watertight carrying case. KA-50 sound calibrator. CV-06 external supply source together with 8614 power supply (Mascot). Weatherproof accessories set for microphone. Microphone extension cable PD5Lx (x stands for cable length, max. 6 m). Microphone extension cable PD7Lx (x stands for cable length, max. 6 m). Supporting stand for microphone: SM2 (2 m height) and SM4 (4 m height). Supporting stand for the instrument: SMR (1.5 m height). 1.2. Weatherproof accessories set for microphone This set enables to convert WK-21 microphone into WK-21WP weatherproof microphone. It consists of: weatherproof version of microphone protecting grid, model SM, rain cover, model OK, windscreen with anti-bird spikes, model TOP, microphone holder. To assemble weatherproof microphone proceed as follows:

Fasten the part (2) of microphone holder to microphone extension cable PD7Lx and next connect this cable to microphone-preamplifier assembly (1) (see Fig. 1.2).

Put part (3) of microphone holder on microphone-preamplifier assembly (1) and then screw it to part (2) of microphone holder fastened earlier to extension cable (see Fig. 1.2). Remove standard protecting grid (4) from WK-21 (see Fig. 1.3). WARNING! During this and next action particular care should be observed as the microphone diaphragm is exposed after protection grid removing and may be easily damaged! Screw SM weatherproof protecting grid (5) to the microphone (see Fig. 1.4). Put OK rain cover (6) on the microphone (see Fig. 1.4). Put TOP windscreen with anti-bird spikes (7) on the microphone assembled as above (see Fig. 1.5) until the windscreen reaches microphone holder. Fig. 1.6 shows completely assembled weatherproof microphone WK-21WP.

1 3

Page 6: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

6

Fig. 1.2. Assembling of weatherproof accessories – step 1.

1 4 Fig. 1.3. Assembling of weatherproof accessories – step 2. 6 5 Fig. 1.4. Assembling of weatherproof accessories – step 3. 7 Fig. 1.5. Assembling of weatherproof accessories – step 4. Fig. 1.6. Completely assembled weatherproof microphone WK-21WP.

1.3. System configuration Basic configuration: DSA-50 digital sound analyzer (manufacturer: SONOPAN). PW21LG ½” microphone preamplifier (manufacturer: SONOPAN). WK-21 ½” measurement microphone (manufacturer: SONOPAN). Other accessories specified in chapter 1.1 are optional.

Page 7: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

7

1.4. Measured quantities Many quantities used to characterize acoustic noise can be measured simultaneously using DSA-50 digital sound analyzer. The set of measured quantities depends on instrument operating mode. Measurement duration and battery condition information is displayed at every operating mode.

1.4.1. Sound level meter (SLM) mode For two frequency weightings, selected among from three ones: A, C and Z available in the instrument, following quantities can be measured simultaneously (in symbols listed below X stands for selected frequency weighting):

LXF current RMS, F-time-weighted sound level, LXFmn minimum RMS, F-time-weighted sound level, LXFmx maximum RMS, F-time-weighted sound level, LXS current RMS, S-time-weighted sound level, LXSmn minimum RMS, S-time-weighted sound level, LXSmx maximum RMS, S-time-weighted sound level, LXI current RMS, I-time-weighted sound level, LXImn minimum RMS, I-time-weighted sound level, LXImx maximum RMS, I-time-weighted sound level, LXPk current peak sound level, LXMPk maximum peak sound level, LXeq time-average (equivalent continuous) sound LXeq1s time-average sound level for last one second.

If A frequency weighting is one of two selected weightings, then following quantities are measured additionally for this weighting:

LAE sound exposure level, LAEX,T noise exposure level referred to specified exposure

1.4.2. 1/1-octave analyzer mode 1/1-octave analyzer contains nine digital octave-band filters having exact centre frequencies specified for binary octave ratio. Nominal centre frequencies are 31.5Hz, 63Hz, 125Hz, 250Hz,500Hz, 1kHz, 2kHz, 4kHz and 8kHz. Specifications of filters conform to Class 1 requirements of EN 61260:1995 and EN 61260:1995/A1:2001. Following quantities can be measured simultaneously for each filter centre frequency (and also for wide-band response), when one frequency weighting is selected among from three available weightings (A, C and Z):

LF current RMS, F-time-weighted sound level, LS current RMS, S-time-weighted sound level, Leq time-average sound level.

Page 8: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

8

If A frequency weighting is selected, then following quantities are measured additionally:

LASmx maximum RMS, A-frequency-weighted, S-time-weighted sound l l LAeq time-average A-frequency-weighted sound level,

LCMPk maximum peak C sound level.

1.4.3. 1/3-octave analyzer mode 1/3-octave analyzer contains twenty nine digital 1/3-octave band filters having exact centre frequencies specified for binary octave ratio. Nominal centre frequencies are 25Hz, 31.5Hz, 40Hz,50Hz, 63Hz, 80Hz, 100Hz, 125Hz, 160Hz, 200Hz, 250Hz, 315Hz, 400Hz, 500Hz, 630Hz, 800Hz, 1kHz, 1.25kHz, 1.6kHz, 2kHz, 2.5kHz, 3.15kHz, 4kHz, 5kHz, 6.3kHz, 8kHz, 10kHz, 12.5kHz and 16kHz. Specifications of filters conform to Class 1 requirements of EN 61260:1995 and EN 61260:1995/A1:2001. Following quantities can be measured simultaneously for each filter centre frequency (and also for wide-band response), when one frequency weighting is selected among from three available weightings (A, C and Z) and when one time weighting is selected among from two available weightings (F and S):

L current RMS sound level, Leq time-average sound level.

1.4.4. Infra G filter mode Following quantities can be measured simultaneously:

LGS current RMS, G-frequency-weighted S-time-weighted sound level, LGSmn minimum RMS, G-frequency-weighted S-time-weighted sound LGSmx maximum RMS, G-frequency-weighted S-time-weighted sound LIPk current peak sound level in infrasound band, LIMPk maximum peak sound level in infrasound band, LGeq G-frequency-weighted time-average sound level.

1.5. Specifications DSA-50 digital sound analyzer conforms to requirements of following standards:

& EN 61672-1:2002 Electroacoustics – Sound level meters – Part 1: Specifications.

& EN 61260:1995/A1:2001 Electroacoustics – Octave-band and fractional-octave- band filters.

& ISO 7196:1995 Acoustics – Frequency-weighting characteristic for infrasound measurements.

DSA-50 conforms to electromagnetic compatibility (EMC) requirements specified in EN 61672-1:2002 for X group instruments.

Page 9: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

9

Accuracy class 1 Readout resolution 0.1dB Maximum sound pressure level can be applied without causing damage to the instrument 150dB (3%

THD) Maximum electrical voltage can be applied at instrument electrical input facility without damage to the instrument 22Vp-p Capacitance of electrical input facility 18pF Reference conditions: - type of sound field free field - reference frequency 1000Hz - reference sound pressure level 94dB - reference level range:

° for 1/1- and 1/3-octave analyzer mode 65 –° for infra G filter mode 65 –

Specifications common for all operating modes: ° for SLM mode 55 – 135dB - sampling frequency: ° for SLM, 1/1- octave and 1/3-octave mode 52.1kHz ° for infra G filter mode 17.4kHz

- Microphone reference direction microphone symmetry axis - microphone reference point microphone diaphragm centre - reference orientation sound wave arriving from reference direction- reference temperature +23°C- reference humidity 50% RH- reference static pressure 101.325kPaPermissible error for sinusoidal reference signal (progressive sound wave incident

di l l

to microphone diaphragm, 94dB, 1000Hz) 0.7dB Operating temperature range -10 +50°CStorage temperature range -10 +50 °C Operating humidity range 90% RH (no

)Operating static pressure range 65 108kPa Electromagnetic emission within the limits specified in EN 61672-1:2002 (maximum emission when operating external power supply) Warm-up time:

- after turn-on 1 minute - after environmental conditions change 15 minutes

Measurement duration 99h 59m 58s (set with 1s or infinite))Serial communication interface USB 1.1

Dimensions (without microphone) 237 x 84 x 50 mm Power supply

Page 10: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

- in - eMinCon micWeNom from

Differeand electrodifferences

nternal batexternal ponimum opentinuous ocrophone hight minal correm instrume

nces betwostatic actus

tteryower supplyerating voltaperating tim

heating turn

ections for ent case (fr

ween WK-2uator respo

y age of inteme (batteryned off)

effects ofree field, 0

1 microphoonse; expa

ernal battery fully

reflection° incidence

one free fieanded (k=2

NiMHMasc

ry 5.5V 24h600g

e) See ta

eld frequen2) uncertai

i

H 6V 2.1Ah ot 5014 (9V

able below

ncy responnty of the d

info@tursdaletec

V, 350mA)

w

nse at 0° indeterminat

chnicalservices.co

)

ncidence tion of thes

o.uk

10

se

Page 11: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

11

Fig. 1.7. Free-field correction for WK-21 microphone (0° incidence).

Table below and Fig. 1.8 show typical free-field frequency response of WK-21 microphone (relative to its sensitivity at 250Hz) together with maximum permissible deviations as specified in EN 61094-4:1995.

Page 12: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

12

Fig. 1.8. Typical free-field frequency response of WK-21 microphone.

1.5.1. Specifications for SLM mode

Frequency weightings A, C, Z AC electrical output (sine, 1000 Hz) - weighted frequency response A, Z - FSD output voltage for level range 14Vp-p - maximum output voltage 22Vp-p - output impedance 1kΩ - load impedance 10kΩ Time weightings SLOW, FAST, IMPULSE

Page 13: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

13

Starting level for level linearity testing reference sound pressure reference level range Maximum unweighted sound pressure level not activating overload indication See table below

Total range for LA sound level and LAeq time-average sound level 18 –

13 dBA Total range for LCPk peak sound level 40 – Extents of measurement range at specified signal frequency, level range and

frequency weighting: - for sound level (L) and time-average sound level (Leq)

Page 14: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

14

- for peak level (LPk)

WARNING! The extents of measurement range for peak level at A and Z frequency weightings are determined for continuous 1000Hz sine signal; measurement error extended by expanded measurement uncertainty is less than 1.1 dB. Self-generated noise - measured with electrical input facility installed: ° at A frequency weighting 13dB ° at C frequency weighting 19dB ° at Z frequency weighting 25dB - measured with WK-21 microphone installed:

° at A frequency weighting 19dB ° at C frequency weighting 24dB ° at Z frequency weighting 27dB

1.5.2 1/1-octave analyzer mode

Frequency weightings A, C, Z AC electrical output (sine, 1000 Hz) - weighted frequency response A, Z - FSD output voltage for level range 14Vp-p - maximum output voltage 22Vp-p - output impedance 1kΩ - load impedance 10kΩ Time weightings SLOW, FAST

Extents of measurement range at specified level range and frequency weighting, for time-weighted sound level L and time-average sound level Leq (analyzer):

Page 15: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

15

Extents of measurement range at specified octave bands and at most-sensitive level range (5 – 75dB), for time-weighted sound level L and time-average sound level Leq (analyzer):

Extent of measurement range for LASmx maximum sound level and LAeq time-average sound level (criterion values 17 – 135dB Extents of measurement range for LCPk peak sound level (criterion values)

Self-generated noise - measured with electrical input facility installed

- measured with WK-21 microphone installed

Page 16: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

16

1.5.2. 1/3-octave analyzer mode

Frequency weightings A, C, Z AC electrical output (sine, 1000 Hz) - weighted frequency response A, Z - FSD output voltage for level range 14Vp-p - maximum output voltage 22Vp-p - output impedance 1kΩ - load impedance 10kΩ Time weightings SLOW, FAST

Extents of measurement range at specified level range and frequency weighting, for time-weighted sound level L and time-average sound level Leq

Extents of measurement range at specified octave bands and at most-sensitive level range(5 – 75 dB), for time-weighted sound level L and time-average sound level Leq

Page 18: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

18

• Self-generated noise - measured with electrical input facility installed

Page 19: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

19

- measured with WK-21 microphone installed

Page 20: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

20

1.5.3. Infra G filter mode

Extents of measurement range at specified level range and frequency weighting, for time- weighted sound level L and time-average sound level Leq Level range G 25 – 105dB TBD 45 – 125dB TBD 65 – 145dB TBD Extents of measurement range for LPk peak sound level Level range G 25 – 105dB TBD 45 – 125dB TBD 65 – 145dB TBD

WARNING! The extents of measurement range for peak level are determined for continuous 10Hz sine signal; measurement error extended by expanded measurement uncertainty is less than 1.1 dB. Self-generated noise - measured with electrical input facility installed ° at G frequency weighting TBD - measured with WK-21 microphone installed: ° at G frequency weighting TBD

Frequency weightings G, I AC electrical output (sine, 1000 Hz) - weighted frequency response Z - FSD output voltage for level range 14Vp-p - maximum output voltage 22Vp-p - output impedance 1kΩ - load impedance 10kΩ Time weightings SLOW Total range for LG sound level and LGeq time-average sound level TBD Total range for LIPk peak sound level TBD

Page 21: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

21

° at A frequency weighting not detectable ° at C frequency weighting ≤ 30.0dB ° at Z frequency weighting ≤ 32.0dB

° at A frequency weighting not detectable ° at C frequency weighting ≤ 30.0dB ° at Z frequency weighting ≤ 31.0dB

° at A frequency weighting not detectable ° at C frequency weighting ≤ 30.0dB ° at Z frequency weighting ≤ 31.0dB

1 2 4 5 6.3 8 10 12.5 16 20 25 135dB 0.07% 0.07% 0.08% 0.08% 0.08% 0.09% 0.09% 0.15% 0.98% 1.9% 1.7%

130dB 0.06%125dB 0.03%

135dB 0.07% 0.07% 0.07% 0.07% 0.07% 0.07% 0.07% - - - -130dB 0.04%125dB 0.03%

1.6. Influence of operating environment Influence of static pressure

- 85kPa108kPa range 0.6dB- 65kPa85kPa range 1.1dB

Influence of temperature 0.8dB Influence of humidity 0.8dB

Influence of vibration see Appendix C conformable to EN 61672-1:2002 specifications (maximum when microphone extension cable is parallel to field direction) Influence of electrostatic field conformable to EN 61672-1:2002

Influence of 80 A/m a.c. power-frequency magnetic field: - SLM mode (15 – 95dB level range)

- 1/1-octave analyzer mode (5 – 75dB level range, f = 63Hz)

- 1/3-octave analyzer mode (5 – 75dB level range, f = 50Hz)

- Infra G filter mode (25 – 105dB level range) TBD

1.7. Influence of instrument accessories Installation of additional equipment does not deteriorate accuracy class of the instrument, however some influence of this equipment on entire instrument performance can be detected. Influence of microphone extension cable its connection to the instrument causes nonlinear distortion increasing with frequency at high input signal levels – see table below.

f [kHz]

Page 22: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

22

Influence of windscreen (at 0º incidence) See table below and Fig. 1.9.

Fig. 1.9. Influence of OP1/2 windscreen.

Page 23: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

23

Influence of weatherproof screen (for 0º incidence) See table below and Fig. 1.10.

Page 24: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

24

2. CONTROLLING OF THE INSTRUMENT DSA-50 digital sound analyzer can be controlled either by instrument keyboard or by PC via USB interface. 2.1. Control keys Instrument keyboard contains following keys: power switch, function keys: MEMORY, FILTER, CLEAR, SETUP, TIME, RESULTS, RUN/PAUSE key, cursor keys, ENTER key .

Page 25: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

25

2.2. Input and output connectors of the instrument The layout of input and output connectors of the instrument is shown on Fig. 2.1 and Fig. 2.2.

The instrument is equipped with following input and output connectors: LEMO EGG.1B.307.CLL microphone connector for microphone preamplifier

Page 26: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

26

GS2-2 analogue AC electrical signal output connector

MJ-14 external power supply connector with 2.1 mm diameter central pin

Page 27: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

27

B-type USB interface connector for data exchange with PC

2.3. Default instrument settings

Default settings of DSA-50 after instrument turn-on are specified below: Operating mode Sound level meter (SLM)

d Level range 55–135dB Frequency weightings A and C Microphone heater Off Measurement history recording Off Integration time 99h 59m 59s (infinite) Noise exposure duration 8h 00m

The instrument setup can be recorded in measurement memory as follows: Turn the instrument on. Set proper operating mode, then select level range, frequency weighting, time weighting (only at 1/3-octave analyzer mode) and microphone heater state (ON or OFF). Save measurement result. To use setup previously recorded, after turning instrument on, open MEMORY menu and load the content of previously filled memory cell.

2.4. Preparation of the instrument to operation Screw WK-21 measurement microphone on microphone preamplifier. Take off microphone protecting cap. Connect this assembly to LEMO microphone connector. If microphone extension cable is to be used, insert it between microphone preamplifier and microphone connector. Place windscreen on the microphone, if necessary. External power supply is optional. External AC mains adaptor or external battery, or internal battery can be used to power the instrument. Turn the instrument on. Default instrument setup is specified in chapter 2.3.Now it is recommended to perform acoustic calibration of the instrument as described in chapter 5.3.After measurements completion, turn the instrument off and place protecting cap on the microphone.

Page 28: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

28

3. OPERATION To operate DSA-50 analyzer, select proper menu among from following: SETUP, RESULTS, TIME, FILTER, MEMORY and CLEAR using function keys. To select proper option of selected menu use arrow keys controlling the cursors. In some menus cursors are used to select proper value directly. Active keys are shown on instrument display. Every setting influencing the measurement, may be modified only when the instrument is set in PAUSE state. In RUN state the information on active keys is not displayed. Particular attention should be paid to results displaying manner in SLM mode. As the room to present measurement results on display screen is far insufficient to show results obtained for all measured quantities, it is necessary to select results to be currently displayed. Detailed description of the method of selection of results to be displayed can be found in chapter 3.3.1.In reduced capabilities version of DSA-50 analyzer following measurement options are unavailable: 1/1-octave analyzer (FILTER 1/1 octave), 1/3-octave analyzer (FILTER 1/3 octave), built-in microphone heater (SETUP MIC HEATER), infra G filter (FILTER infra G). If any of unavailable options is selected, then error message is displayed on the screen.

Fig. 3.1. Error message displayed when unavailable option is selected.

3.1. Instrument data plate After turning the instrument on, initial information is displayed on the screen. This information contains instrument name, firmware version and manufacturer data (name, website, phone).

Fig. 3.2. Instrument data plate.

Page 29: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

3.2. SETTo recall thTo changinstrumentTo changavailable fof three a WARNING Analogue below: S

1/

In

To changetime weighweightingsF time weS time wei WARNING To turn miIf the instchange is

TUP menhis menu p

ge level rat operatingge frequenfrequency available fr

G! Results

signal, ava

LM mode:

/1- or 1/3-o

nfra G filter

e RMS timhtings are s simultaneeightings sighting.

G! Results

crophone rument is disabled a

nu press SETange pres

g mode. Mency weigh weighting

requency w

s of last m

ailable at in

octave ana

r mode:

me weightinavailable.

eously. In imultaneou

s of last m

heater on in RUN s

and informa

UP key. ss or easuremenhting presgs are selweightings

easureme

nstrument

alyzer mode

ng in 1/3-oIn SLM m 1/1-octaveusly. In infr

easureme

or off in allstate, presation on ac

arrownt results ass arrlected. In is selected

ent are cle

AC signal

e:

octave anamode RMSe analyzerra G filter m

ent are cle

l operatingsent instructive keys i

w key. Leare not afferow key. 1/1- or 1

d.

eared by fr

output is fr

alyzer modresults ar

r mode remode, all m

eared by ti

g modes prment settiis not disp

i

evel rangeected by lev In SLM 1/3-octave

requency

requency-w

e, press re determinesults are measureme

ime weigh

ress kengs can blayed.

info@tursdaletec

e setting dvel range c mode tw

e analyzer

weighting

weighted a

arrow kned at S, F determineents are de

hting chan

y. be only wa

chnicalservices.co

2

depends ochange.

wo of threr mode on

g change!

as shown

key. F andF and I tim

ed at S anetermined

nge!

atched –

o.uk

29

on

ee ne

S me nd at

its

Page 30: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

Fi

Fig. 3.5. S

3.3. RESIn DSA-50depends okey. Following overload indicator, Two mode Under-ranlimit,then or is not m WARNINGindicate number imay be eto cause

Measurem displayed AdditionallMicrophonwhen heatBattery ga

ig. 3.3. SETU

SETUP menu

SULTS m0 analyzeon instrume

data areindicator (microphon

es of overlo – overlo – overlo

ge indicat is displa

measured y

G! It may signal le

is displayexplained anumeric r

ment state i – RUN – PAUS –

stands foly in SLM m

ne heater ter is turne

auge can b

P menu at SL

u at 1/3-octav

menu er several ent operat

e displaye(not visibl

ne heater soad conditioad has ocoad has oction is alsayed left oyet, then th

happen evel in eed as powas followseadout, bu

is indicatedstate (mea

SE state (m– waiting

or number omode, propstate is in

ed off and te displaye

LM mode.

ve analyzer m

sets of ing mode b

ed at eacle if no o

state indicaions are inccurred duccurred aftso displayef result nu

he icon

the instrvery freqwer sum fs: signal ut power s

d by followasurementmeasuremfor instrumof secondsper inscriptndicated sthe icon d as follow

Fig

mode.

results arbeing in us

ch operatioverload hator (On/Ofdicated: ring last seer measured. If dispumber. Add is disp

rument in quency bfor entirelevels in psum of the

wing icons:t in progresent stoppement reads remainedtion:imilarly as

is displaws:

g. 3.4. SETUP

Fig. 3.6. SET

e availablse. To sele

ng modehas beenff) and batt

econd, ement starplayed resditionally, iplayed inst

1/1- or band as

frequencparticularese levels

ss), ed), diness to od to the end

,s overloadayed when

i

P menu at 1/1

TUP menu at

le. The nect active s

: measureoccurred

tery gauge

rting but nosult is belif signal letead of res

1/3-octavenot meas

cy range (r frequencs is suffici

operation; d of waiting

, i: its indica

n heater is

info@tursdaletec

1-octave anal

t infra G filte

umber of set use

ement du), RUN/PA

e.

ot during laow level

evel is not sult numbe

e analyzesurable, ( o respectcy bands aent to cau

the numbg period . s displaye

ator is notturned on.

chnicalservices.co

3

lyzer mode.

er mode.

these se or arro

ration timAUSE sta

ast secondrange lowmeasurabr.

r mode twhereas tively). are too louse it.

ber

d. t visible

o.uk

30

ets ow

me, ate

d. wer ble

o a It

ow

Page 31: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

If battery ithen in somagainst exunder too

3.3.1. SAs many modify prekey when result selelines (seepossible toonly one qbe modifieAnalogue deflection specified b

F

Analogue

– full ch – 75% – 50% – 25% – fully d

s fully discme time th

xtremely delow supply

SLM mod quantitie

edefined seany prede

ection cure Fig. 3.7)o turn off quantity dised. Press

signal leis proport

below

Frequency selec

A/CA/ZZ/CZ/Z

level indica

harge, charge, charge, charge, dischargedcharged anhe instrumeeep dischay voltage,

de es are mets of dispefined set sor enablin. Press the displaysplay is of

key wvel indicational to F

weighting cted C ZCZ

ator makes

d. nd no exteent is turnearge and fowhen decl

measured played resu

is displayng the cha

or ky in selectpresent inhen in set

ator is disF-time-weig

s the selec

rnal powered off. It isor disablingared meas

simultaneoults. To enyed. Whenange of diskey to selted line, foterest. Pret modificatsplayed neghted soun

Q

an

ction of opt

r supply isnecessaryg the meassurement a

ously in nter resultn set modsplayed quect any o

or instanceess or tion mode ear lowernd pressu

Quantity dinalogue lev

LA

LALZ

LZ

timum leve

i

connectedy for protecsurementsaccuracy m

this modset modificdification muantity appf available

e to improv key to

to disableborder o

re level a

isplayed byvel indicatoAF AF

ZF

ZF

el range ea

info@tursdaletec

d to the inscting the bas to be permay not be

e, it is cation modmode is e

pears at one quantitieve readabi select dis

e this modeof display at frequenc

y or

asier.

chnicalservices.co

3

strument, attery rformed achieved.

possible de press entered, thne of displaes. It is alsility or whesplay line e.

screen. cy weightin

o.uk

31

to

he ay so en to

Its ng

Page 32: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

Another weighting

3.3.2. 1If predefincursor to sband is dmarked as

predefinedg setting A/

/1-octavned resultsselect bar isplayed ns represe

d sets of r/C or A/Z is

e analyzs set no. representi

numericallyents measu

results (ress selected

zer 1, 2 or 3

ing signaly near lowured signa

sults set n) are show

3 is displalevel in on

wer displayal power su

no. 4 is avwn below:

ayed, thenne of frequy border. Mum from all

i

vailable on

use uency bandMost right octave ba

info@tursdaletec

nly if frequ

and kds. Result bar, some

ands.

chnicalservices.co

3

uency

key to movfor selecte

ewhat wide

o.uk

32

ve ed er,

Page 33: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

If A frequeused for oOn the smeasuremmode (sedisplay scsound leveasier. Another pr

3.3.3. 1Use afrequency border. Mosum from

ency weigccupationascreen co

ment state, ee Fig. 3creen. Its

vel (LAS). A

redefined s

/3-octavand ke

bands. Rost right ba all 1/3-oc

hting is seal noise meorrespondi micropho.7). Analog deflectioAnalogue

sets of res

e analyzey to movResult for ar, somewctave band

et, then reeasuremenng to rene heatergue signan is proplevel indic

ults are sh

zer modeve cursorselected

hat wider,ds.

esults set nts, is avaisults set

r state, baal level indportional tcator mak

hown on the

e to selectband is d

, marked

no. 4, conlable. no. 4 t

attery gaugdicator is dto A-frequkes the se

e figures b

bar repredisplayedas represe

i

ntaining as

he layoutge etc. is displayed ency-weig

election of

below:

esenting snumericall

ents mea

info@tursdaletec

ssessment

t of icons identical near lowe

ghted S-timoptimum

signal levely near losured sig

chnicalservices.co

3

paramete

s indicatinas for SL

er borderme-weighte

level rang

el in oneower displagnal pow

o.uk

33

ers

ng LM

of ed ge

of ay

wer

Page 34: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

34

3.3.4. Infra G filter mode Analogue signal level indicator is displayed near lower border of display screen. Its deflection is proportional to G-frequency-weighted S-time-weighted sound level (LGS). Analogue level indicator makes the selection of optimum level range easier.

Page 35: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

Anoth

3.4. SETTo activanoise expreference Measuremrunning mtime indicduration. WARNINGautomaticinfinite. Ezero at ind The expocompletionLAEX, T is reRecently pto be edite

To edit sedigit is to bpress k

her predefi

TUP TIMEte this m

posure timtime), date

ment duraeasureme

cation (dis

G! When c stoppingElapsed tdication 1

osure timen. e-calculatepreset valued. When s

elected mebe changekey to conf

ned sets o

E menu menu pressme (necess

e and timeation (a.knt is automplayed on

measureg of meatime indic00:00:00.

e may b

ed automatues are disselection is

enu positioed, then usfirm setting

of results a

s TIME ksary to c

e for real-tim.a.: integmatically sn RESULT

ement dasuremenation (dis

e set be

tically aftersplayed ons done pre

on use arrose andg. The instr

re shown o

key. It encalculate nme clock bration tim

stopped. TTS menu s

uration int is disaplayed on

efore mea

r exposuren the scress key

ow keys. P key to

rument ret

on the figu

nables to noise expobuilt in the ime) is thhis time inscreen) is

s set aabled an

n RESULT

asurement

time chanen. Pressto enter ed

Press oset desireurns then t

i

res below:

preset mosure leveinstrumenthe time nterval is r equal to

t 99h 59d measu

TS menu s

begin or

nge. or

dit mode.

or key d value. Ato SETUP

info@tursdaletec

measuremeel LAEX, T t. interval a

reached whpreset m

9m 59s urement dscreen) is

r after m

key to se

to select After editing

TIME men

chnicalservices.co

3

nt duratio for pres

after whichen elapse

measureme

(99:59:59duration then set

measureme

lect positio

place wheg completionu.

o.uk

35

on, set

ch ed

ent

9), is to

ent

on

ere on

Page 36: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

To abandMEMORY

3.5. FILTThis menis practica(operating no 1/ 1/ inUse an WARNING

don edit mY, FILTER o

TER menu makes

ally equiva mode corone (SLM /1 octave (/3 octave (nfra G (infrnd key t

G! Results

mode presor CLEAR)

nu possible tlent to oprespondingmode), (1/1-octave(1/3-octavera G filter mto select fil

s of last m

ss any fun). Changed

to select perating mog to given

e analyzere analyzer

mode). ter, then p

easureme

nction keyd number t

filter to bode selectfilter is spe

r mode), r mode),

press ke

ent are cle

y (SETUPthen will no

e used dtion. Filterecified in p

ey to confir

eared after

i

P, TIME, Rot be stored

uring instrrs specifiedparenthese

rm selectio

r operating

info@tursdaletec

RESULTSd.

rument opd below as).

on.

g mode ch

chnicalservices.co

3

,

peration –are availab

hange!

o.uk

36

it ble

Page 37: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

3.6. MEDSA-50 ameasuremTo select submenu displayed.

3.6.1. SStoring ofAll results measuremrecord mePress opening Scell is avadisplayed displayed.displayed.To confirm

key. Maximum

MORY manalyzer

ment result desired o

press k

Save meaf measure of presen

ment may easuremen

or keySAVE MEAailable then

near low If there

m storing m

forty meas

menu at every and also r

option preskey. Prese

asure ment resunt measurbe contint results aty to selecASURE sun cell no. 1er left cosome da

measure re

surement r

operatingrecording oss or ent status o

ult is possrement togued aftert every instt memory

ubmenu th1 is suggerner of thata are s

esults in s

results can

g mode eof measure

key. Toof measure

sible only gether withloading th

trument opcell the m

he numberest. The stahe screenaved then

selected m

n be saved

enables sement histoo enter seement hist

when meh instrumehe measuperating momeasuremr of first fratus of sel. If it isn date an

memory cel

.

i

saving anory. elected optory record

asurementent settingrement reode. ent result ree cell islected cell free thend time of

ll press

info@tursdaletec

nd loading

ption and oding (On or

t process gs are stoesult. It is

is to be s displayed(Free or O inscriptiof saved m

key, to c

chnicalservices.co

3

g of sing

open propr Off) is als

is stoppeored, so th

possible

saved. Aftd. If no freOccupied)on FREEmeasure a

cancel pres

o.uk

37

gle

per so

ed. he to

ter ee is is

are

ss

Page 38: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

3.6.2. LLoading oresults areis possiblestate, regaTo select and time oof selectedIf no data displayed.

3.6.3. MThe time is possibledone durineach of inbe select5s. The recordepends onumber of

The numbMaximum

Load meaof saved ree displayede to continardless it wmemory c

of stored md cell pressare stored

Measuremhistory of

e to recorng noise mnstrument ted amon

rded valuon instrumf quantities

ber of prforty meas

asure esult is pod, the instrnue this mwas On or cell, from w

measure is s key od in instru

ment hisf measurerd values monitoringoperating g from fo

es are tment operas to be reco

resent hissurement h

ossible onrument ch

measuremeOff duringwhich datadisplayed

or press ment mem

tory ement is r

of selecte). Record mode. T

ollowing: 1s

these meating modeorded. It is

story is dihistories ca

nly when mange its sent. Measstoring.

a should bnear lowe to cancel

mory then t

recorded ined quantitiing of meime intervs, 5s, 10s,

asured sine, time intes displayed

splayed nan be reco

measuremettings tourement h

be loadeder left corne. the messa

ndependenies in preeasuremenval betwee 15s, 30s

nce lasterval betwed near lowe

near upperded.

i

ent procesloaded fro

history rec

use aer of the sc

age: NO D

ntly of meedefined timnt history en subseqand 60s. D

recording. een subseer left corne

er right co

info@tursdaletec

ss is stopom memorording rem

nd keycreen. To

DATA IN M

easuremenme intervacan be pquent recoDefault tim

The recequent recer of the sc

orner of

chnicalservices.co

3

pped. Storery cell andmains in O

ys. The daload conte

MEMORY!

nt results. als (as it erformed ordings ca

me interval

cording timcordings ancreen.

the scree

o.uk

38

ed it

Off

ate ent

is

It is at an is

me nd

en.

Page 39: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

To changturn meas

key. Wmeasuremquantities on instrum

3.6.3.1. This operdeterminedmeasuremquantities selected, Xare as follo LX LX LX LX LX LX LX LXTo selectquantity copress quantity is

e time insurement hWhen histo

ment. To scan be rec

ment operat

SLM morating modd for time

ment run, can be r

X in subscows: XFmn mXFmx mXSmn mXSmx mXImn mXImx mXMPk mXeq tt numberorrespondkey. When assigned

terval betwhistory recory record

select quancorded deting mode.

ode de enablese interval the time

recorded cript stand

minimum Fmaximum minimum Smaximum Sminimum I-maximum maximum time-averar of quaing to seln horizontato given n

ween subcording on

ding is turnntities to bpends .

s to recoelapsedinterval

(the sames for frequ

F-time-weigF-time-wei

S-time-weigS-time-wei-time-weigI-time-weigpeak levelge sound ntity to blected numal dashes aumber.

bsequent mn press ned on thebe recorde

rd valuessince lasis takene set of quency weig

ghted RMSighted RMSghted RMSighted RMhted RMSghted RMS, level. be recordmber presare display

measurem key. To

e data recd press

of 1 tot recordinsince me

quantitiesghting)

S level, S level, S level, S level, level,

S level,

ded pressss or yed instead

i

ents preso stop his

cording be key. Th

6 quantitieng. As foreasuremenfor both

s or key. d of quant

info@tursdaletec

s or story recogins after e number

es. All qur first recnt run mofrequency

key. To confirity symbol

chnicalservices.co

3

key. Tording pres

running thand sort

uantities aording aftoment. Th

y weighting

To selem selectioit means n

o.uk

39

To ss he of

are ter he gs

ect on no

Page 40: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

3.6.3.2. This operdeterminedmeasuremcan be rec LX LX LXTo selectquantity copress quantity is

1/1-octarating modd for time

ment run, thcorded for XFmx mXSmx mXeq tt numberorrespondkey. When assigned

ave analyde enablese interval he time intall filters (X

maximum maximum Stime-averar of quaing to seln horizontato given n

yzer mods to reco

elapsedterval is taX in subscF-time-weiS-time-weige sound ntity to blected numal dashes aumber.

de rd valuessince lasken since

cript standsighted RMSighted RMlevel. be recordmber presare display

of 1 tot recordinmeasurem

s for frequeS level, S level,

ded pressss or yed instead

i

3 quantitieng. As forment run mency weigh

s or key. d of quant

info@tursdaletec

es. All qur first rec

moment. Thhting) are a

key. To confirity symbol

chnicalservices.co

4

uantities aording afthe quantitieas follows:

To selem selectioit means n

o.uk

40

are ter es

ect on no

Page 41: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

3.6.3.3. This operadeterminedmeasuremcan be rec

LXY Leq

To selectquantity copress quantity is

3.6.3.4. This operadeterminedmeasuremcan be rec

LGS LGS LIM LGe

To selectquantity copress quantity is

1/3-octaating moded for time

ment run, thcorded for

Ymx maxiwei

q time

t number orrespondkey. When assigned

Infra G fating moded for time

ment run, thcorded are

Smn minlSmx max

MPk maxeq G-fr

t numberorrespondkey. When assigned

ave analye enables tinterval elahe time inteall filters a

ximum RMghting selee-average

of quaning to seln horizontato given n

filter mode enables tinterval elahe time inte as follows

nimum RMSlximum RM

ximum pearequency-w

r of quaing to seln horizontato given n

yzer modto record vapsed sincerval is tak

are as follow

MS level (Xected)sound lev

ntity to blected numal dashes aumber.

de to record vapsed sincerval is tak

s:

S, G-frequMS, G-frequak sound leweighted ti

ntity to blected numal dashes aumber.

de values of 1ce last recoken since mws:

X stands for

el.

be recordmber presare display

values of 1ce last recoken since m

ency-weiguency-weigevel in infraime-averag

be recordmber presare display

to 2 quanording. Asmeasurem

r frequency

ed pressss or yed instead

to 4 quanording. Asmeasurem

hted S-timghted S-timasound bage sound l

ded pressss or yed instead

i

ntities. All qfor first recent run mo

y weighting

or key. d of quant

ntities. All qfor first recent run mo

me-weightedme-weighteand,evel.

s or key. d of quant

info@tursdaletec

quantities acording aftoment. The

g selected,

key. To confirity symbol

quantities acording aftoment. The

d sound ed sound

key. To confirity symbol

chnicalservices.co

4

are ter e quantities

, Y for

To selem selectioit means n

are ter e quantities

To selem selectioit means n

o.uk

41

s

ect on no

s

ect on no

Page 42: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

3.6.4. FThis mewhether mthe measu

3.7. CLEThis menlast measuWhen memTo select press result is dRESULTS WARNING

FREE/OCnu displa

measuremeurement is

EAR menu enablesurement (nmory contaoption pre key. The deleted di

S menu is d

G! Memory

CCUPIEDays inforent historyrunning.

nu s to clearnot stored iains no datess or

option LArectly by displayed (

y clearing

menu rmation oy is recorde

r entire mn memoryta the mes

key. ToAST MEASpressing (with result

cannot be

on numbed in mem

memory ory). sage NO D

o enter selSURE is

key. Ats set rece

e reversed

er of omory. Thes

r its part

DATA IN Mlected optihere an e

After deletntly selecte

d!

i

occupied se data are

and also

MEMORY! on and dis

exception, ing of lased).

info@tursdaletec

memory e available

to delete

is displayesplay propas last mt measure

chnicalservices.co

4

cells ane also whe

e results

ed. per submenmeasuremeement resu

o.uk

42

nd en

of

nu ent ult

Page 43: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

3.7.1. MTo select are displayclear selec

3.7.2. MTo delete press t

Measure number oyed near lcted cell or

Measuremlast histor

to cancel.

in memoof cell to beft border r key to

ment hisry recorde

ory be cleared

of the scro clear all c

tory d press

d press reen. Whecells; press

key. To

or ken desired

s to can

clear enti

i

ey. Measurcell is sele

ncel.

ire history

info@tursdaletec

rement daected pres

memory p

chnicalservices.co

4

ate and timss key

press k

o.uk

43

me to

key;

Page 44: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

3.7.3. EThe mess

key. To

4. CODSA-

using origCD su in U in in AdThe store instru

5. REC

During do pemicrochanmicro w

du prof wi

do not apequipped preamplifie

Entire meage requiro cancel cl

MMUN-50 shouldginal interfaupplied witstallation pSB D2XX struction mstruction fodobe Readsoftware on PC’s

ument is po

COMENg instrumeo not remoerform allophone or

nges whenophone is hen removuring screwrotect the nd (use wi

pply exceswith facilit

er equippe

emory ring to confearing pre

NICATIOd be conneace cable, h the instrupackage ofdevice driv

manual for or device dder to viewmakes po

s hard disossible. Da

NDATIOent use folloove micropl connectir extensionn the instnot conneving or insw driving) tmicrophonindscreen!

ssive forceties to avo

ed with LEM

firm clearinss key

ON WIected withsupplied t

ument conf Windowsver, the softwa

driver instaw PDF docuossible dowk, and ex

ata transmi

NS FORowing recohone proteion changn cable) otrument iscted to its stalling mito avoid unne against),

e to conneoid impropMO plug is

ng of all da.

TH COh battery-ptogether wtains follow

s based PC

are in PDFallation in Puments. wnloading

xport to otssion proto

R INSTRommendatiection grid ges (connnly whens turnedpreamplifiecrophone

nwanted remechanic

ect or disper conne shown on

ata is disp

OMPUTpowered Pith the instwing data:C software,

format, PDF format

data fromther prograocol is ava

RUMENTions shouldif not nece

necting orthe instrumon, or tuer can leadprotecting

emoving ofcal shocks

connect Lction; the

n Fig. 5.1.

i

layed. To

TER PC class ctrument.

t,

m DSA-50ams. Also

ailable on r

T USE d be strictlessary, r disconnement is tuurning thed to instrum

g cap use f micropho, dust, mo

LEMO conway to d

info@tursdaletec

confirm cle

computer U

0, manipuo, remote request.

y observed

ecting of urned off; e instrumement damaslight rota

ne protectioisture and

nectors asisconnect

chnicalservices.co

4

earing pres

USB interf

late, analcontrol of

d:

preamplimaking thent on wage, ation righting grid,

d strong gu

s these amicrophon

o.uk

44

ss

face

yze, the

fier, ese hen

(as

usts

are ne

Page 45: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

Fig. 5.1. Dis

5.1. RecFasten theat a distadisturbancmeasuremIf existingthe micropSETUP m

5.2. InteThe instruTo charggauge is dto chargeautomatic battery. It is possib WARNINGis necess

WARNINGon!

5.3. CalCorrect mRecommeThis devic1000 Hz of nominaalso used Calibrationmode). To co tu

sconnecting

commene instrumeance (fromce. Selectment. g ambientphone, useenu (see c

ernal battment is noe the badisplayed

e fully discturn-off of

ble to opera

G! If the iary to rec

G! The ba

ibration measuremeended sounce producenominal frl sound prfor calibra

n of the ino perform couple caliburn the cali

g of microph

dations fnt (or its mm the inst level ra

t temperae built-in mchapter 3.2

tery ormally opeattery, coin RESULcharged bf the instru

ate the ins

nstrumenharge bat

ttery char

of the inent can nd calibrates calibraterequency. ressure levtion. nstrument calibration obrator with tbrator on,

hone preamp

for corremicrophonestrument oange ens

ture and microphone2).

erated withnnect extLTS menuattery is 1ument) bef

strument co

nt is not ittery in ord

rging proc

nstrumenbe perforor for DSA

ed sound sAnother so

vel and fre

is performof the instrthe microp

plifier equip

ect perfoe) to its supor its micuring to

humidity e heater. T

internal bternal pow

u at each 12 hours.fore charg

ontinuously

n use forder to avo

ceeds reg

nt rmed onlyA-50 analysignal of 9ound calibquency eq

med at refrument corphone,

ped with LE

rming ofpporting strophone)avoid ov

can leadThe heate

attery suppwer suppinstrumenIf possibleing. Avoid

y using ext

r time lonoid its self-

gardless th

y when cyzer is SON94 dB nomrator of cla

quivalent to

ference lerrectly:

i

EMO connec

f measurtand and eassuring

verload or

d to vapoer can be t

ply. ly to the

nt operatine, fully dis

charging

ternal powe

nger than -discharge

he instrum

calibrated NOPAN KAminal sounass 1 or bo KA-50 so

evel range

info@tursdaletec

ctor.

rements ensure youto avoid r underra

our condeturned on

e instrumeg mode. T

scharge baof partially

er supply.

two mone.

ment is tu

instrumenA-50 sounnd pressuretter, prod

ound calibr

(55135d

chnicalservices.co

4

u are locatesound fie

ange durin

ensation oor off usin

ent. BatteTypical timattery (upy discharge

ths, then

urned off o

nt is usend calibratore level an

ducing signrator, can b

dB for SL

o.uk

45

ed eld ng

on ng

ery me to ed

it

or

ed. or. nd nal be

LM

Page 46: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

46

run the measurement and check if displayed sound pressure level is equal to 93.8dB. At present coupling of the microphone with sound source this indication corresponds to 94dB sound pressure level at free-field conditions, if instrument indication deviates from value mentioned above, then correct indication by turning calibration potentiometer located on instrument right-side panel (see Fig. 2.2) using supplied small screwdriver.

WARNING! During calibration the instrument together with sound calibrator shall not be exposed to noise higher than nominal sound pressure level of sound calibrator in use or ground vibration.

5.4. Warranty SONOPAN grants the warranty on following stipulations: no remains of changes, corrections, crossing-out etc. are found on Warranty Card, the instrument shall be used according to manufacturer Instruction Manual, the warranty becomes void if instrument repairs or modifications are undertaken by unauthorized persons. SONOPAN warrants this instrument: to be fulfilling the specifications given in Instruction Manual, to be working correctly for 12 months from purchase date in 24 months from date the instrument was produced. Not covered by this warranty: damages resulting from instrument transportation (provided no clear neglects of manufacturer have been stated), mechanical damages through the fault of the purchaser, internal damages through the fault of the purchaser. The purchaser is entitled to warranty claim only when instrument dealer does not meet his obligations resulting from this warranty. 5.4.1. Complaint instructions for the purchaser: contact SONOPAN and specify the cause of complaint, Warranty Card number, date and place of purchase and date the instrument was produced, after complaint receipt is confirmed send the instrument with Warranty Card included to SONOPAN by freight company, if SONOPAN service find instrument damage to be not covered by warranty or warranty conditions to be not fulfilled, then the purchaser is obliged to cover service and transport costs as specified in the bill made out by SONOPAN, the costs specified above are covered by SONOPAN if the complaint is accepted.

Page 47: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

47

5.5. Maintenance and repair DSA-50 digital sound analyzer requires no special maintenance treatments. All repairs of the instrument are performed by the manufacturer.

6. CE MARKING AND CONFORMANCE TO EU COUNCIL DIRECTIVES The product described in this instruction conforms to following EU Council Directives:

89/336/EEC Electromagnetic compatibility

The conformance to above-mentioned requirements is confirmed by CE mark.

This product cannot be thrown away with household waste. Deposit the product in an authorized electrical and electronic waste collection area for recycling. Contact local Municipal Bureau or nearest waste disposal company to get more detailed information.

Appendix A. Filter characteristics

Page 51: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

51

Appendix B. Directional responses

Page 53: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

[email protected]

53

Appendix C. Sensitivity to vibration

Page 54: Manual Sound level meter PCE DSA 50 - PCE Instruments˜ LIPk current peak sound level in infrasound band, ˜ LIMPk maximum peak sound level in infrasound band, ˜ LGeq G-frequency-weighted

In this directionhttp://www.indu NOTE: "Thisatmospheres

will find a visioustrial-needs.com

s instrument s (powder, fl

Fig. C.3

n of the measurm/measuring-in

doesn’t haveammable ga

3. Sensitivity

rement techniqunstruments.htm

e ATEX proteases)."

of DSA-50 to

ue:

ection, so it s

o Z-directed v

should not b