Mains-linked PV Static Converter “RESUN“ and Biaxial Tracking System “Railtrak“ Technical Documentation Function and Components

Mains-linked PV Static Converter “RESUN“gpt-power.com/en/Resun-function.pdf · Mains-linked PV Static Converter “RESUN ... Due to comfortable Windows-based software the user

Embed Size (px)

Citation preview

Mains-linked PV Static Converter

“RESUN“

and Biaxial Tracking System

“Railtrak“

Technical Documentation Function and Components

2

Index Page

Position of the Static Converter Sytem „RESUN“ in market comparison 3

Function and components of the Static Converter Sytem „RESUN“ 5

System Operating Management 6 Static converter modules (Power amplifier) 8 WR 1500 8 WR 5000 10 Combined sensor 12

Static converter basic units, INDOOR 14 Wandgehäuse WG 3 14 Wandgehäuse WG 6 16 Standschrank SG 12 18 Standschrank SG 24 20 Optional housings, INDOOR 22 ESG 12 22 ESG 24 24 Static converter basic units, OUTDOOR 26 ASG 12 26 ASG 24 28 Optional housings, OUTDOOR 30 ASGE 12 30 ASGE 24 33

3

Position of the mains-linked PV static converter system “RESUN“ in market comparison

The mains-linked PV static converter system “RESUN“ is a LF-non-transformer three-wire sinus static converter to provide the low voltage network of the power supply companies with direct current power from PV generators. With two basic units of static converter power amplifiers WR1500 (1,5 kVA) and WR5000 (5 kVA) in modular design the required static converter total power of 1,5 kVA up to 1280 kVA can be reached by parallel connection of max. 256 power amplifiers at present.

Unlike other PV static converters, in the “RESUN“ system the in series connected string converters control the MPP-Tracking of the PV modules, not the static converter. They collect direct current power of the connected PV modules string by string and transform it to a common intermediate circuit voltage line which leads to the static converter. So the advantages of string static converters and central static converters are combined.

Like this, it is - for instance - possible to operate up to 30.000 string converters on just one static converter with an appropriate total power, But in regard to

- the string voltage (max. 800 V DC)

- the cell technology (amporphous, polycrystalline, monocrystalline...)

- the arrangement e. g. at a building

- the module temperature

- the adjustment to the sun

the PV string may have absolutely different characteristics without to be afraid of mismatching loss.

For optimum adaption to PV generators (even in difficult applications like in buildings) various compon-ents are availble - there are no limits for the further development of the "RESUN static converter in the PV generator technology:

string converter for stationary PV strings: SK31, SK32, SK61, SK121

string converter for biaxial tracking PV strings: SK31T, SK61T, SK121T

static converter basic units, indoor: WG3, WG6, SG12, SG24

static converter extension units, indoor: ESG12, ESG24

static converter basic units, outdoor: ASG12, ASG24

static converter extension units, outdoor: ASGE12, ASGE24

The biaxial tracking system “Railtrak“ offers a low-cost opportunity to raise the annual generator output up to 45% compared to optimum stationary adjustment - which means an enormous increase of profit of PV systems. And it is also possible to operate stationary and tracking systems simultaneously with one static converter.

Position of the mains-linked PV static converter “RESUN“ compared to other static converter systems established in the market:

4

In case the total power of a static converter of 1280 kVA should not be sufficient, up to 16 static converters can be aligned to a system in master-slave-combination up to 20480 kVA. Various options allow a remote control of the static converter, e. g. via modem, or, on request of powers suppliers, to integrate it into load management systems.

Due to comfortable Windows-based software the user can monitor the static converter and the service crew can configer the system.

An (applied for patent) automatical „process to prevent unintended island-operation when operating self-producing systems at the low voltage network of the EVU“ has not the always accessible disconnecting switch point also in systems with total power <4,6 kVA resp. 30 kVA, whereas “RESUN“ feeds 3-wire any time.

The table below shows the position of the mains-linked static converter system “RESUN“ compared to other mains-linked PV static converters established in the market:

Principle Principle switching MPP-Trackingmodularstatic converter

stringstatic converter

centralstatic converter

staticconverter"RESUN"with string and modularconverters

via modular static converter for each PV modul

via string static converter string by string

via central static converter for whole PV generator

via string converter string by stringvia modular converter module

MPP-Tracking is decoupled from static converter

supply

supply

supply

supply

5

Function and components of the static converter system "RESUN"

R, S, T, N, PE3 x 400 V, 50 Hzmax. 1280 kVA

string converter,stationary

PV modules, stationarySK31,SK32,SK61,SK121

SK31T,SK61T,SK121T

ESTS

BFR

counter

azimuth

PV modules, tracked

"Railtrak"

stringconverter,tracked

elev

atio

n

dat

a

combined sensor

"RESUN"- basic unitsWG3, WG8, SG12, SG24 (INDOOR)ASG12, ASG24(OUTDOOR)

5

PV modules:amorphous,polycrystalline,monocrystalline

"RESUN"- extension unitsESG12, ESG24 (INDOOR)ASGE12, ASGE24 (OUTDOOR)

6

Description

The system operating management provides following main features:

- aquisition and display of operating relevant measuring values and status information - administration and power control of the static converter power amplifiers - communication with connected string converters - supply network monitoring and prevention of unintended island-operation - communication with further static converter basic units "RESUN“ acc. to master-slave-concept (up to 15 slaves) - proceeding information via interfaces to data terminals like modem, fax-alarm, PC - temperature control of the housings - temperature monitoring and dewing protection - Data logging

Application

System operating management for static converter basic units "RESUN“. To fullfill all its tasks the system operating management contains three components:

1. BFR-CPU (Art.-Nr. 557020 resp. 558020)

16-Bit microprocessor assembly in flash-technology with interface drivers

2. BFR-IO (Art.-Nr. 557030 resp. 558030)

Power supply and signal conditioning for microprocessor

System operating management (BFR)

7

3. BFR-display (Art.-Nr. 557040 bzw. 558040)

Display assembly, LCD-display with touch-screen and backlighting, LED-signal for operation, MPP and error (collective error message)

signal LEDs

LCD-display

ON- / OFF-switch

Technical data

- Graphic-compatible LCD-display with backlighting - Touch-panel 2 x 5 keys - 16-Bit microprocessors: 2 pcs. - Power supply: prim.: supply 230 Vac sec.: +3,3 V, +5 V, +15 V, -15 V - Power consumption: operation: 1,5....10 W (depending on „RESUN“ type) sleep mode: <1 W - Electrical connection: plug terminal, reversed polarity protected - Interfaces: RS232 PC, modem / fax-alarm, reserve RS485 counter remote display power interface ext. data logger, measuring transmitter, slaves JTAG operating system access WR unit-internal interface to control static converter power amplifiers SK unit-internal interface to control string converter

External data logger

LCD-display

with touch-screen

DC - ZK AC - NetzService PC Modem Slaves

JTAG RS232 ISS RS232 ISS

WRSS SKSS ISS RS485

BFR - CPUBFR - IO

Power supply

RS232Reserve

Counter

Measuring transmitter

Sym T1 T2 T3 T4 T5 T6 ZK- ZK+

ZK +

PE

ZK -

8WR1500

R S T N Lst

8

Static converter power amplifier 1,5 kVA (plug assembly WR1500 Art.-Nr. 554010)

Description

- 3-wire, no transformer, current supplied 6-pulse push/pull-converter with nominal power 1,5 kVA to supply the direct current intermediate circuit power into the low voltage network - service friendly 19“ plug assembly with frontside plug connectors - latest IGBT-technology, high grade of efficieny (96,5%), low-noise - permanent short circuit-proof - complete with own system processor in flash-technology to connect with an internal unit-bus, IGBT-power amplifier, sinus-filter, EMV-filter, supply disconnect relay

Diagram of principle

Poc = 1,5 kVA Tu = -20 °C...+50 °CUi = 850 V DC (nominal)Ua = 3 x 400 V AC - 50 / 60 Hzfa = 32 kHz

JTAG unit-BUS, internal

static converter internal system processor with self-controlled current regulator, not for island-operation

to system operating management (BFR)

9

Application

- Static converter power amplifier for application in mains-linked PV static converters "RESUN“

Technical data

- Nominal power: 1,5 kVA - Wires: 3 - Rotating field: right - Nominal input voltage DC: 850 V - Nominal input current DC: 1,8 A - Nominal output voltage AC: 3 x 400 V - Nominal current AC: 3 x 2,18 A - Mains frequency: 49,8...50,2 Hz - Grade of efficiency eta: 96,5% *) - cos phi: 0,99...1,0 *) - Operating principle: push-pull current supplied, no NF-transformer - Operating frequency: 32 kHz - Harmonic distortion: <2% *) - Power amplifier cooling: forced ventilation 1,0 W - Noise emission: <30 db(A) - Control mode: current quality self-controlled cos phi mains-controlled

- Weight 3,75 kg - Dimensions: 6HE, 1SP (=14TE) *) at nominal power

Grade of efficiency as function of the AC-power

power (AC) / nominal power (AC)

gra

de

of

effi

cien

cy (

eta)

Sym T1 T2 T3 T4 T5 T6 ZK- ZK+

ZK +

PE

ZK -

8WR5000

R S T N Lst

10

Poc = 1,5 kVA Tu = -20 °C...+50 °CUi = 850 V DC (nominal)Ua = 3 x 400 V AC - 50 / 60 Hzfa = 32 kHz

JTAG unit-BUS, internal

static converter internal system processor with self-controlled current regulator, not for island-operation

to system operating management (BFR)

Static converter power amplifier 5,0 kVA (plug assembly WR5000 Art.-Nr. 554020)

Description

- 3-wire, no transformer, current supplied 6-pulse push/pull-converter with nominal power 5,0 kVA to supply the direct current intermediate circuit power into the low voltage network - service friendly 19“ plug assembly with frontside plug connectors - latest IGBT-technology, high grade of efficieny (96,5%), low-noise - permanent short circuit-proof - complete with own system processor in flash-technology to connect with an internal unit-bus, IGBT-power amplifier, sinus-filter, EMV-filter, supply disconnect relay

Diagram of principle

11

Application

- Static converter power amplifier for application in mains-linked PV static converters "RESUN“

Technical data

- Nominal power: 5,0 kVA - Wires: 3 - Rotating field: right - Nominal input voltage DC: 850 V - Nominal input current DC: 5,9 A - Nominal output voltage AC: 3 x 400 V - Nominal current AC: 3 x 7,3 A - Mains frequency: 49,8...50,2 Hz - Grade of efficiency eta: 96,5% *) - cos phi: 0,99...1,0 *) - Operating principle: push-pull current supplied, no NF-transformer - Operating frequency: 32 kHz - Harmonic distortion: <2% *) - Power amplifier cooling: forced ventilation 2,8 W - Noise emission: <45 db(A) - Control mode: current quality self-controlled cos phi mains-controlled

- Weight 14,45 kg - Dimensions: 6HE, 3SP (=42TE) *) at nominal power

Grade of efficiency as function of the AC-power

power (AC) / nominal power (AC)

gra

de

of

effi

cien

cy (

eta)

12

Combined sensor ESTS (Art.-Nr. 557170)

Description The combined sensor for global insolation and outdoor temperature is connected to the static converter basic units „RESUN“ and is component of each "RESUN“ basic unit and is indispensable for the function of the static converter. Based on the insolation values measured by the sensor the system operating ma-nagement determines how many of the available static converter power amplifiers are necessary at the moment. The total power at the static converter power amplifier is designed for 1000 W/m² as a rule. For example: the sensor measures a present global insolation of 200 W/m², the system operating manage-ment switches off 80% of the power amplifiers and controls with not more than 20% to the operating point. The outdoor temperature is measured for compensation purposes and relevant for the dewing protection. Based on the sensors key function some basic rules have to be regarded at installation to ensure a proper function of the total system.

1. Basically the sensor has to be mounted with its light receiver vertically upright to the sky.

2. Select a location that ensures the sensor is not in a shaded area during the time the PV generator shall operate. Therefore the sensor should be mounted appr. 30 cm above the module level of the PV generator to avoid any shadow on the modules (use special sensor bracket). 3. In systems with lightning protection unit the sensor has to be mounted at least 1,5 m away from parts of the lightning protection system and at least 1 m below the top of the lightning conductor.

4. Avoid nearby chimneys or flues as well as similar sources of pollution (Danger of contamination which might cause measuring errors).

5. Design connecting cables between sensor and static converter just as long as necessary (max. 25 m) and use only cable type LiYCY 2 x 2 x 0,5 mm² (screened) and connect the screen only to the static converter.

Application

- Measuring the diffuse radiation of the sky without albedo and the outdoor temperature - Measuring value independant of direction of radiation - Mounting close to solar generators without shading - for connection with static converter basic units "RESUN“

13

Technical data

Measuring system outdoor temperature

Type of sensor: PTCResistance nominal: 10 k at +25 °C Tolerance: +/-1%Characteristic-linearization: software *)

Measuring system global insolation Type of sensor: photo resistor with diffusorResistance ati 0 W/m²: 10 k at 1000 W/m²: 1 k Characteristic-linearization: software *)Protection class: IP65Housing material: polycarbonateColour: greyCable entry: cable gland M12 with strain reliefElectrical connection: clamp terminalWeight: appr. 150 g Ambient temperature: -25 °C...+70 °C

*) The characteristic-linearization is made by the system operating management of the static converter basic units "RESUN“.

Option

Description: bracket for combined sensor Art.-Nr.: 557180

14

Description

- static converter basic unit "RESUN“ for indoor mounting - wall mounting - for static converter plug assembly WR1500 resp. WR5000 - wired "ready-to-connect" - inclusive combined sensor (insolation and outdoor temperature) - system operating management with LCD-display and touch-panel - no disconnection switch necessary

Diagram of principle

Static converter basic unit WG3

DC-ZK850 V DC

WR 1

supply (counter)R, S, T, N, PE50 Hz

WR 2 WR n

n = x + y

BFR - CPU BFR - IO display

WG 3

15

Technical data

- Wall housing: sheet steel - Colour: RAL7032 / RAL5010 - max. number of plug assemblies: 3 - Protection class: IP21 - Weight (without assemlies): appr. 7 kg - Cable entry: from bottom with cable gland - Cable connections: Mains output (AC): clamp terminal (max. 6 mm²) Intermediate circuit (DC): clamp terminal (max. 4 x 6 mm²) - Ambient temperature: -20 °C...+50 °C - Display: LCD-display with backlighting and touch-panel - Standby power consumption: appr. 1 W

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA) Art.-Nr.

1 - 1,5 555000 2 - 3,0 555010 - 1 5,0 555020

Options

Description Art.-Nr.

Dewing protection 554300 Potential-free contact „collective error“ 554310 Contact for remote switching „static converter on/off“ 554320 Control contact external fan/air condition 554330 Industrial modem, analog 554340 Fax-alarm 554350 PC connection cable 554360 PC interface on clamp 554370 PC interface as wall mounting socket on plaster 554380 concealed 554390 Slave interface (RS232 up to 10 m) 554400 Interface adapter RS232-RS485 554410 Programmable adapter (only qualified personnel) 554420 Tracker-SV 554430

16

Static converter basic unit WG6

DC-ZK850 V DC

WR 1

supply (counter)R, S, T, N, PE50 Hz

WR 2 WR n

n = x + y

BFR - CPU BFR - IO display

WG 6

Description

- static converter basic unit "RESUN“ for indoor mounting - wall mounting - for static converter plug assembly WR1500 resp. WR5000 - wired "ready-to-connect" - inclusive combined sensor (insolation and outdoor temperature) - system operating management with LCD-display and touch-panel - no disconnection switch necessary

Diagram of principle

17

Technical data

- Wall housing: sheet steel - Colour: RAL7032 / RAL5010 - max. number of plug assemblies: 6 - Protection class: IP21 - Weight (without assemlies): appr. 10 kg - Cable entry: from bottom with cable gland - Cable connections: Mains output (AC): clamp terminal (max. 6 mm²) Intermediate circuit (DC): clamp terminal (max. 2 x 4 x 6 mm²) - Ambient temperature: -20 °C...+50 °C - Display: LCD-display with backlighting and touch-panel - Standby power consumption: appr. 1 W

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA) Art.-Nr.

1 - 1,5 555000 2 - 3,0 555010 - 1 5,0 555020

Options

Description Art.-Nr.

Dewing protection 554300 Potential-free contact „collective error“ 554310 Contact for remote switching „static converter on/off“ 554320 Control contact external fan/air condition 554330 Industrial modem, analog 554340 Fax-alarm 554350 PC connection cable 554360 PC interface on clamp 554370 PC interface as wall mounting socket on plaster 554380 concealed 554390 Slave interface (RS232 up to 10 m) 554400 Interface adapter RS232-RS485 554410 Programmable adapter (only qualified personnel) 554420 Tracker-SV 554430

18

Static converter basic unit SG12

Description

- static converter basic unit "RESUN“ for indoor mounting - upright housing on socket - for static converter plug assembly WR1500 resp. WR5000 - wired "ready-to-connect" - selective DC- and AC-safety for each static converter level- inclusive combined sensor (insolation and outdoor temperature) - system operating management with LCD-display and touch-panel - no disconnection switch necessary

Diagram of principle

DC-ZK850 V DC

WR 1

supply (counter)R, S, T, N, PE50 Hz

WR 2 WR n

n = x + y

BFR - CPU BFR - IO display

SG 12

19

Application

- establishing 3-wire no transformer static converters for network input - power range 11,5...20 kVA without extension unit (up to 1280 kVA with extension) - installation in closed and dry rooms without high air humidity and condensate (DIN VDE 0100 T.731/ 02.86)

Technical data - Upright housing: sheet steel on socket - Colour: RAL7032 / RAL5010 - max. number of plug assemblies: 12 - Protection class: IP21 - Weight (without assemlies): appr. 60 kg - Cable entry: from bottom via socket - Cable connections: Mains output (AC): clamp terminal (2 x max. 4 x 25 mm²) Intermediate circuit (DC): clamp terminal (2 x max. 4 x 25 mm²) - Ambient temperature: -20 °C...+50 °C - Display: LCD-display with backlighting and touch-panel - Standby power consumption: appr. 1 W

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA) Art.-Nr.

1 2 11,5 555060 2 2 13,0 555070 - 3 15,0 555080 1 3 16,5 555090 2 3 18,0 555100 - 4 20,0 555110

Options

Description Art.-Nr.

Dewing protection 554300 Potential-free contact „collective error“ 554310 Contact for remote switching „static converter on/off“ 554320 Control contact external fan/air condition 554330 Industrial modem, analog 554340 Fax-alarm 554350 PC connection cable 554360 PC interface on clamp 554370 PC interface as wall mounting socket on plaster 554380 concealed 554390 Slave interface (RS232 up to 10 m) 554400 Interface adapter RS232-RS485 554410 Programmable adapter (only qualified personnel) 554420 Tracker-SV 554430

20

Static converter basic unit SG24

Description

- static converter basic unit "RESUN“ for indoor mounting - upright housing on socket, wired "ready-to-connect" - for static converter plug assembly WR1500 resp. WR5000 - inclusive combined sensor (insolation and outdoor temperature)- selective DC- and AC-safety for each static converter level- system operating management with LCD-display and touch-panel - no disconnection switch necessary up to 30 kVA

Diagram of principle

DC-ZK850 V DC

WR 1

supply (counter)R, S, T, N, PE50 Hz

WR 2 WR n

n = x + y

BFR - CPU BFR - IO display

SG 24

21

Application

- establishing 3-wire no transformer static converters for network input - power range 11,5...20 kVA without extension unit (up to 1280 kVA with extension) - installation in closed and dry rooms without high air humidity and condensate (DIN VDE 0100 T.731/ 02.86)

Technical data - Upright housing: sheet steel on socket - Colour: RAL7032 / RAL5010 - max. number of plug assemblies: 24 - Protection class: IP21 - Weight (without assemlies): appr. 90 kg - Cable entry: from bottom via socket - Cable connections: Mains output (AC): clamp terminal (2 x max. 4 x 25 mm²) Intermediate circuit (DC): clamp terminal (2 x max. 4 x 25 mm²) - Ambient temperature: -20 °C...+50 °C - Display: LCD-display with backlighting and touch-panel - Standby power consumption: appr. 1 W

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA) Art.-Nr.

1 4 21,5 555012 2 4 23,0 555013 - 5 25,0 555014 1 5 26,5 555015 2 5 28,0 555016 - 6 30,0 555017 1 6 31,5 555018 2 6 33,0 555019 - 7 35,0 555020 1 7 36,5 555021 2 7 38,0 555022 - 8 40,0 555023

Options

Description Art.-Nr.

Dewing protection 554300 Potential-free contact „collective error“ 554310 Contact for remote switching „static converter on/off“ 554320 Control contact external fan/air condition 554330 Industrial modem, analog 554340 Fax-alarm 554350 PC connection cable 554360 PC interface on clamp 554370 PC interface as wall mounting socket on plaster 554380 concealed 554390 Slave interface (RS232 up to 10 m) 554400 Interface adapter RS232-RS485 554410 Programmable adapter (only qualified personnel) 554420 Tracker-SV 554430

22

Static converter extension unit ESG12

Description

- static converter extension unit "RESUN“ for indoor mounting to extend performance of the basic units SG12 to maximum 256 pcs. static converter plug assemblies - upright housing on socket - for static converter plug assemblies WR5000 - wired "ready-to-connect", incl. shunt switch for internal unit-bus - selective DC- and AC-safety for each static converter level

Diagram of principle

DC-ZK850 V DC

WR 1

to / frombasic unit

WR 2 WR n

n = x + yAC

BFR - IO display

ESG 12

IGBUS

23

Application

- establishing 3-wire no transformer static converters for network input - installation in closed and dry rooms without high air humidity and condensate (DIN VDE 0100 T.731/ 02.86) - installation right next to the basic unit or back to back - electrical connection to the basic unit via socket

Technical data - Upright housing: sheet steel on socket - Colour: RAL7032 / RAL5010 - Max. number of plug assemblies: 12 - Protection class: IP21 - Weight (without assemlies): appr. 60 kg - Cable entry: from bottom via socket - Cable connections: Mains output (AC): clamp terminal (2 x max. 4 x 25 mm²) Intermediate circuit (DC): clamp terminal (2 x max. 4 x 25 mm²) - Ambient temperature: -20 °C...+50 °C

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA)* Art.-Nr.

- 1 5,0 555240 - 2 10,0 555250 - 3 15,0 555260 - 4 20,5 555270

*) The total power is the sum of the power of the basic unit and the extension units(s).

Options

Description Art.-Nr.

Dewing protection 554300

24

Static converter extension unit ESG24

Description

- static converter extension unit "RESUN“ for indoor mounting to extend performance of the basic units SG24 to maximum 256 pcs. static converter plug assemblies - upright housing on socket - for static converter plug assemblies WR5000 - wired "ready-to-connect", incl. shunt switch for internal unit-bus - selective DC- and AC-safety for each static converter level

Diagram of principle

DC-ZK850 V DC

WR 1

to / frombasic unit

WR 2 WR n

n = x + yAC

BFR - IO display

ESG 24

IGBUS

25

Application

- establishing 3-wire no transformer static converters for network input - installation in closed and dry rooms without high air humidity and condensate (DIN VDE 0100 T.731/ 02.86) - installation right next to the basic unit or back to back - electrical connection to the basic unit via socket

Technical data - Upright housing: sheet steel on socket - Colour: RAL7032 / RAL5010 - Max. number of plug assemblies: 24 - Protection class: IP21 - Weight (without assemlies): appr. 90 kg - Cable entry: from bottom via socket - Cable connections: Mains output (AC): clamp terminal (2 x max. 4 x 25 mm²) Intermediate circuit (DC): clamp terminal (2 x max. 4 x 25 mm²) - Ambient temperature: -20 °C...+50 °C

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA)* Art.-Nr.

- 1 5,0 555280 - 2 10,0 555290 - 3 15,0 555300 - 4 20,0 555310 - 5 25,0 555320 - 6 30,0 555330 - 7 35,0 555340 - 8 40,0 555350

*) The total power is the sum of the power of the basic unit and the extension units(s).

Options

Description Art.-Nr.

Dewing protection 554300

26

Static converter basic unit ASG12 (Outdoor)

DC-ZK850 V DC

WR 1

supply (counter)R, S, T, N, PE50 Hz

WR 2 WR n

n = x + y

BFR - CPU BFR - IO display

ASG 12

Description

- static converter basic unit "RESUN“ for outdoor mounting - upright housing on socket, stainless steel powder coated RAL 7032 - for static converter plug assembly WR1500 resp. WR5000 - wired "ready-to-connect" - selective DC- and AC-safety for each static converter level- system operating management with LCD-display and touch-panel - no disconnection switch necessary up to 30 kVA

Diagram of principle

27

Application

- establishing 3-wire no transformer static converters for network input - power range 1,5...20 kVA without extension unit (up to 1280 kVA with extension) - outdoor installation in covered locations acc. DIN VDE T.737 / 11.90

Technical data - Upright housing: sheet steel on socket - Colour: RAL7032 / RAL5010 - max. number of plug assemblies: 24 - Protection class: IP44 - Weight (without assemlies): appr. 90 kg - Cable entry: from bottom via socket - Cable connections: Mains output (AC): clamp terminal (2 x max. 4 x 25 mm²) Intermediate circuit (DC): clamp terminal (2 x max. 4 x 25 mm²) - Ambient temperature: -20 °C...+50 °C - Display: LCD-display with backlighting and touch-panel - Standby power consumption: appr. 1 W

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA) Art.-Nr.

1 4 21,5 556120 2 4 23,0 556130 - 5 25,0 556140 1 5 26,5 556150 2 5 28,0 556160 - 6 30,0 556170 1 6 31,5 556180 2 6 33,0 556190 - 7 35,0 556200 1 7 36,5 556210 2 7 38,0 556220 - 8 40,0 556230

Options

Description Art.-Nr.

Dewing protection 554300 Potential-free contact „collective error“ 554310 Contact for remote switching „static converter on/off“ 554320 Control contact external fan/air condition 554330 Industrial modem, analog 554340 Fax-alarm 554350 PC connection cable 554360 PC interface on clamp 554370 PC interface as wall mounting socket on plaster 554380 concealed 554390 Slave interface (RS232 up to 10 m) 554400 Interface adapter RS232-RS485 554410 Programmable adapter (only qualified personnel) 554420 Tracker-SV 554430

28

Static converter basic unit ASG24 (Outdoor)

Description

- static converter basic unit "RESUN“ for outdoor mounting - upright housing on socket, stainless steel powder coated RAL 7032 - for static converter plug assembly WR1500 resp. WR5000 - wired "ready-to-connect" - selective DC- and AC-safety for each static converter level- system operating management with LCD-display and touch-panel - no disconnection switch necessary up to 30 kVA

Diagram of principle

DC-ZK850 V DC

WR 1

supply (counter)R, S, T, N, PE50 Hz

WR 2 WR n

n = x + y

BFR - CPU BFR - IO display

ASG 24

29

Application

- establishing 3-wire no transformer static converters for network input - power range 1,5...20 kVA without extension unit (up to 1280 kVA with extension) - outdoor installation in covered locations acc. DIN VDE T.737 / 11.90

Technical data - Upright housing: sheet steel on socket - Colour: RAL7032 / RAL5010 - max. number of plug assemblies: 24 - Protection class: IP44 - Weight (without assemlies): appr. 90 kg - Cable entry: from bottom via socket - Cable connections: Mains output (AC): clamp terminal (2 x max. 4 x 25 mm²) Intermediate circuit (DC): clamp terminal (2 x max. 4 x 25 mm²) - Ambient temperature: -20 °C...+50 °C - Display: LCD-display with backlighting and touch-panel - Standby power consumption: appr. 1 W

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA) Art.-Nr.

1 4 21,5 555012 2 4 23,0 555013 - 5 25,0 555014 1 5 26,5 555015 2 5 28,0 555016 - 6 30,0 555017 1 6 31,5 555018 2 6 33,0 555019 - 7 35,0 555020 1 7 36,5 555021 2 7 38,0 555022 - 8 40,0 555023

Options

Description Art.-Nr.

Dewing protection 554300 Potential-free contact „collective error“ 554310 Contact for remote switching „static converter on/off“ 554320 Control contact external fan/air condition 554330 Industrial modem, analog 554340 Fax-alarm 554350 PC connection cable 554360 PC interface on clamp 554370 PC interface as wall mounting socket on plaster 554380 concealed 554390 Slave interface (RS232 up to 10 m) 554400 Interface adapter RS232-RS485 554410 Programmable adapter (only qualified personnel) 554420 Tracker-SV 554430

30

Static converter extension unit ASGE12 (Outdoor)

Description

- static converter extension unit "RESUN“ for indoor mounting to extend performance of the basic units ASG12 to maximum 256 pcs. static converter plug assemblies - upright stainless steel housing on socket - for static converter plug assemblies WR5000 - wired "ready-to-connect", incl. shunt switch for internal unit-bus - selective DC- and AC-safety for each static converter level

Diagram of principle

DC-ZK850 V DC

WR 1

to / frombasic unit

WR 2 WR n

n = x + yAC

BFR - IO display

ASGE 12

IGBUS

31

Application

- establishing 3-wire no transformer static converters for network input - outdoor installation in covered locations acc. DIN VDE T.737 / 11.90- installation right next to the basic unit or back to back - electrical connection to the basic unit via socket

Technical data - Upright housing: stainless steel on socket - Colour: RAL7032 / RAL5010 - Max. number of plug assemblies: 12 - Protection class: IP44 - Weight (without assemlies): appr. 60 kg - Cable entry: from bottom via socket - Cable connections: Mains output (AC): clamp terminal (2 x max. 4 x 25 mm²) Intermediate circuit (DC): clamp terminal (2 x max. 4 x 25 mm²) - Ambient temperature: -20 °C...+50 °C

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA)* Art.-Nr.

- 1 5,0 556240 - 2 10,0 556250 - 3 15,0 556260 - 4 20,5 556270

*) The total power is the sum of the power of the basic unit and the extension units(s).

Options

Description Art.-Nr.

Dewing protection 554300

32

Static converter extension unit ASGE24 (Outdoor)

Description

- static converter extension unit "RESUN“ for indoor mounting to extend performance of the basic units ASG24 to maximum 256 pcs. static converter plug assemblies - upright stainless steel housing on socket - for static converter plug assemblies WR5000 - wired "ready-to-connect", incl. shunt switch for internal unit-bus - selective DC- and AC-safety for each static converter level

Diagram of principle

DC-ZK850 V DC

WR 1

to / frombasic unit

WR 2 WR n

n = x + yAC

BFR - IO display

ASGE 24

IGBUS

33

Application

- establishing 3-wire no transformer static converters for network input - outdoor installation in covered locations acc. DIN VDE T.737 / 11.90- installation right next to the basic unit or back to back - electrical connection to the basic unit via socket

Technical data - Upright housing: stainless steel on socket - Colour: RAL7032 / RAL5010 - Max. number of plug assemblies: 24 - Protection class: IP44 - Weight (without assemlies): appr. 90 kg - Cable entry: from bottom via socket - Cable connections: Mains output (AC): clamp terminal (2 x max. 4 x 25 mm²) Intermediate circuit (DC): clamp terminal (2 x max. 4 x 25 mm²) - Ambient temperature: -20 °C...+50 °C

Pre-wired "ready-to-connect" for x pcs. WR1500 and y pcs. WR5000

WR1500 (x) WR5000 (y) Pmax (kVA)* Art.-Nr.

- 1 5,0 556280 - 2 10,0 556290 - 3 15,0 556300 - 4 20,0 556310 - 5 25,0 556320 - 6 30,0 556330 - 7 35,0 556340 - 8 40,0 556350

*) The total power is the sum of the power of the basic unit and the extension units(s).

Options

Description Art.-Nr.

Dewing protection 554300