40
Low Slope Fastening Solutions Guide Featuring Products & Systems

Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

  • Upload
    vutruc

  • View
    232

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

Low Slope Fastening Solutions GuideFeaturing Products & Systems

Page 2: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R
Page 3: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

1SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Table of Contents

Section Page

General Information

Dekfast Identification Convention ..............2

Fasteners

#12 Phillips Head ........................................3

#12 Hex Head .............................................4

#14 Phillips Head ........................................5

#15 Phillips Head .....................................6-7

Stress Plates

Insulation Plates ...................................... 8-9

Membrane Plates ................................10-11

Specialty Fastening

#12 Purlin ..................................................12

Insulation Panel Fastener .........................13

#14 Stainless ............................................14

isotak® .......................................................15

Deklite™ ................................................16-17

Dekspike™ ............................................18-19

ZAC Anchors ............................................20

Zinc Nailins................................................21

Base Ply/Twin Loc-Nail Fasteners ...........22

Termination and Batten Bars .............. 23-24

Section Page Rooftop Productivity Tools & Systems

isofast® Insulation Attachment .................25

isofast® Membrane Attachment ..............26

isoweld® Induction Welding System .......27

TPR-L Peel Rivet System .........................28

Stealth Pre-Assembly Tool .................29-30

Reference

Approved FM Fastening Patterns ............31

Fastener Selection ....................................32

Page 4: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

2SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Difference-making with Dekfast™

SFS intec has delivered fastening solutions for over fifty years to worldwide markets. The Dekfast™ brand is universally understood as the premier choice by specifiers and contractors for commercial low slope (flat roof) applications.

Fastening SolutionsDekfast™, an innovative and proven solution, is

designed, manufactured and tested to achieve

compliance with Factory Mutual (FM) 4470. Having

a wide variety of materials, thread styles, point

geometries, finishes and installation applications,

Dekfast is a preferred choice for insulation and

membrane attachment in wood, steel and concrete

decks.

Productivity SolutionsSFS intec offers stand-up roofing tools to

increase productivity and provide ergonomic

benefits to roofing contractors. Having used

SFS intec tools, contractors have reported

significant rooftop productivity gains for

insulation and membrane attachment … in

some cases productivity is "3x" faster. isofast®

and isoweld® are unmatched in the industry

and provide contractors with the edge required

to get on and off of the roof more quickly.

Job-Site SolutionsSFS intec provides rooftop consultation,

training and start-up support at no cost to the

market. Our rooftop training programs are

geared towards creating customer confidence

and competence with all of the Dekfast™ brand

offerings as well as our productivity tools. Job

site solutions include:

• pull tests

• project start-up

• rooftop crew training

Office-Based SolutionsSupporting the Dekfast™ brand is our highly

differentiated eSolutions service offering.

eSolutions is a web-based application which

streamlines customer order placement, tracking,

invoicing, etc. eSolutions empowers customers

to be in control of their material requirements.

Using eSolutions will lead to improved order

accuracy and reduced supply chain costs.

Page 5: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

3SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Dekfast Identification ConventionSFS intec "Intelligent Product Code"

Product TypeBB-R Coiled Batten BarBP Base PlyDF DekfastDL DekliteIPF Insulated Panel FastenerPLT PlatePUR PurlinSPK SpikeTB-AP Term Bar - All purposeTB-DB Term Bar - Drain BarTB-F Term Bar - FlatTB-FBB Flat Batten BarTB-LB Term Bar - Lip and BallTB-RSL Term Bar - Ribbed Single LipTB-R Term Bar - Ribbed TB-SL Term Bar - Single LipTLN Twin Loc-NailTPR Peel RivetZA ZAC Anchor ZNI Zinc Nail in

PlatesPLT Plate DesignationFL-P isoweld®

DL Deklite PlateG3 3" Round Galvalume (pre-assembled)H HexHR Hex RecessO OblongP PlasticR RoundS SquarexB Barbed & # of barbs

Material TypeS4 Stainless 400 series

Head Type/DriveHWx/x Hex Washer HeadPHx/x PhillipsCHWx/x Cupped Hex Washer Head PC Pancake HeadSQx/x Square Drive

WasherN Neoprene Seal Washer

CoatingE0999 E-Coat Black

PackagingB Bulk in cartons or pailsBL BeltedC 100/bag or boxCTN Carton TUBE Tube

D F - # 1 2 x 3 - 3 / 4 - P H 3 - E 0 9 9 9 - B

ProductType

Dimensions Head/Drive Coating Type& Color Code

Packaging

#12 Dekfast, 3-3/4” Length, #3 Phillips Drive, E-Coat Black, Bulk/Pail

I P F - # 1 4 x 4 - P C - S Q 3 - E 0 9 9 9 - B

ProductType

Dimensions Head Coating Type& Color Code

PackagingDrive

#14 Insulation Panel Fastener, 4” Length, Pancake Head, #3 Square Drive, E-Coat Black, Bulk/Pail

2-3/8” Galvalume Steel Round, Barbed Plate (6 Barbs). Bulk/Pail

P LT - R - 2 - 3 / 8 - 6 B - B

ProductType

Shape OutsideDimension

Barbs Packaging

Page 6: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

4SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Fasteners

#12 Phillips Head #3 Phillips drive, 13 tpi, drill pointFor insulation attachment to wood and steel roof decks

Application#12 Dekfast FastenersAvailable pre-assembled and loose for insulation attachment to steel and wood.Materials: • Steel thickness from 22 ga (.028 in.)

through 18 ga (.045 in.): Min penetration: 3/4"

• Wood 2x (1-1/2" thick): Min penetration: 1"

• Plywood: Min thickness: 3/4" FR treated; min through penetration: 1/4"

Use with: • Dekfast 3" round metal plates

and 2-7/8" hex metal plates• Dekfast 3" round plastic Dekflat plates

NotesDimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Selection Fastener *Thread Material No. Carton Carton Skid Length Length Phillips Head North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty.

1-5/8" Full 785683 DF-#12x1-5/8-PH3-E0999-B Up to 7/8" Up to 5/8" N/A 13 1,000 60,000

2-1/4" Full 785698 DF-#12x2-1/4-PH3-E0999-B 5/8" to 1-1/2" Up to 1-1/4" N/A 17 1,000 60,000

2-7/8" Full 785717 DF-#12x2-7/8-PH3-E0999-B 5/8" to 2-1/8" Up to 1-1/8" N/A 21 1,000 60,000

3-1/4" 3" 785735 DF-#12x3-1/4-PH3-E0999-B 1/2" to 2-1/2" 1/2" to 2-1/4" N/A 23 1,000 60,000

3-3/4" 3" 785761 DF-#12x3-3/4-PH3-E0999-B 1" to 3" 1" to 2-3/4" N/A 26 1,000 60,000

4-1/2" 4" 785781 DF-#12x4-1/2-PH3-E0999-B 3/4" to 3-3/4" 3/4" to 3-1/2" N/A 31 1,000 40,000

5" 4" 785797 DF-#12x5-PH3-E0999-B 1-1/4" to 4-1/2" 1-1/4" to 4" N/A 34 1,000 40,000

6" 4" 785818 DF-#12x6-PH3-E0999-B 2-1/4" to 5-1/4" 2-1/4" to 5" N/A 41 1,000 40,000

7" 4" 785835 DF-#12x7-PH3-E0999-B 3-1/4" to 6-1/4" 3-1/4" to 6" N/A 24 500 30,000

8" 4" 785851 DF-#12x8-PH3-E0999-B 4-1/4" to 7-1/4" 4-1/4" to 7" N/A 28 500 30,000

* Note - Thread length measured from tip of the drill point to end of threads.

Approvals

InstallationTools: 2000 – 2500 rpm screw guns with hardened #3 Phillips bit. #12 Dekfast fasteners can be pre-assembled with metal or plastic insulation plates.

The standard carton package includes one #3 Phillips bit.

Head Types: #3 Phillips Head Height: Max .118" Head Dia: Max .448" Thread Major Dia: .222" Shank Dia: .167"Strength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815Pull-out: (lbs avg.): Steel 22 ga: 513 Steel 20 ga: 695 Steel 18 ga: 787 2x dimensional lumber (1" penetration): 462 3/4" FR Plywood (through penetration): 575

• Available with #3 Phillips drive.• Drill point design prevents fastener walking.• 13 threads per inch provides higher pull-out values.

• Drill point cuts through gravel and BUR.• e-coat

OptionsInsulation Plates

AssembliesBelted Systems

Installation Tools

12-1017.07

State of Florida: FL20311

Page 7: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

5SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

#12 Hex Head 1/4" hex drive, 13 tpi, drill pointFor insulation attachment to wood and steel roof decks

Fasteners

Application#12 Dekfast FastenersAvailable pre-assembled and loose for insulation attachment to steel and wood.Materials: • Steel thickness from 22 ga (.028 in.)

through 18 ga (.045 in.): Min penetration: 3/4"

• Wood 2x (1-1/2" thick): Min penetration: 1"

• Plywood: Min thickness: 3/4" FR treated; min through penetration: 1/4"

Use with: • Dekfast 2-7/8" hex plates • Dekfast 3" round plastic Dekflat plates

NotesDimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Selection Fastener *Thread Material No. Carton Carton Skid Length Length Hex Head North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty.

1-5/8" Full 790081 DF-#12x1-5/8-HW1/4-E0999-B Up to 7/8" Up to 5/8" N/A 14 1,000 60,000

2-1/4" Full 790087 DF-#12x2-1/4-HW1/4-E0999-B 5/8" to 1-1/2" Up to 1-1/4" N/A 18 1,000 60,000

2-7/8" Full 790090 DF-#12x2-7/8-HW1/4-E0999-B 5/8" to 2-1/8" Up to 1-1/8" N/A 23 1,000 60,000

3-1/4" 3" 790093 DF-#12x3-1/4-HW1/4-E0999-B 1/2" to 2-1/2" 1/2" to 2-1/4" N/A 26 1,000 60,000

3-3/4" 3" 790099 DF-#12x3-3/4-HW1/4-E0999-B 1" to 3" 1" to 2-3/4" N/A 29 1,000 48,000

4-1/2" 4" 790102 DF-#12x4-1/2-HW1/4-E0999-B 3/4" to 3-3/4" 3/4" to 3-1/2" N/A 34 1,000 40,000

5" 4" 790105 DF-#12x5-HW1/4-E0999-B 1-1/4" to 4-1/2" 1-1/4" to 4" N/A 37 1,000 40,000

6" 4" 790108 DF-#12x6-HW1/4-E0999-B 2-1/4" to 5-1/4" 2-1/4" to 5" N/A 44 1,000 40,000

7" 4" 790115 DF-#12x7-HW1/4-E0999-B 3-1/4" to 6-1/4" 3-1/4" to 6" N/A 25 500 30,000

8" 4" 790118 DF-#12x8-HW1/4-E0999-B 4-1/4" to 7-1/4" 4-1/4" to 7" N/A 28 500 30,000

* Note - Thread length measured from tip of the drill point to end of threads.

Approvals

InstallationTools: 2000 – 2500 rpm screw guns with 1/4" hex head drive bits. #12 hex head Dekfast fasteners are available pre-assembled with metal insulation plates.

The standard carton package includes one #1/4" Hex socket for HWH

Head Types: 1/4" Hex Head Head Height: Max .118" Head Dia: Max .448" Thread Major Dia: .222" Shank Dia: .167"Strength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815Pull-out: (lbs avg.): Steel 22 ga: 513 Steel 20 ga: 695 Steel 18 ga: 787 2x dimensional lumber (1" penetration): 462 3/4" FR plywood (through penetration): 575

• Available with 1/4" hex head.• Drill point design prevents fastener walking.• 13 threads per inch provides higher pull-out values.

• Drill point cuts through gravel and BUR.• e-coat

OptionsInsulation Plates

AssembliesInstallation Tools Coatings

12-1017.07

State of Florida: FL20311

Page 8: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

6SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

#14#3 Phillips drive, 10 tpi, drill point

For insulation and membrane attachment to wood, steel, and structural concrete roof decks

Fasteners

Application#14 Dekfast FastenersInsulation board to roof deckMaterials: • Steel thickness from 22 ga (.028 in.)

through 18 ga (.045 in.): Min penetration: 3/4"

• Plywood: Min thickness: 3/4" FR treated; min through penetration: 1/4"

• Wood 2x (1-1/2" thick): Min penetration: 1"• Structural concrete: Min penetration: 1"Use with: • Dekfast 2-7/8" hex plates• Dekfast 3" round plastic Dekflat plates• Other attachment elements approved by the

roofing system manufacturer for use with its products

NotesDimensions are nominal inches unless noted. Steel roof decks include all FM-approved 18-20-22 ga. FM-approved wood decks include 3/4" FR plywood and 2x dimensional lumber. Structural concrete to be predrilled with standard 3/16" carbide bit to minimum 1/2" deeper than fastener penetration. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Selection Fastener *Thread Material No. Carton Carton Skid Length Length Phillips Head #14-10 North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty.

1-1/4" Full 1202602 DF-#14x1-1/4-PH3-E0999-B Up to 1/2" Up to 1/4" Up to 1/4" 12 1,000 60,000

2" Full 1203249 DF-#14x2-PH3-E0999-B Up to 1-1/4" Up to 1-1/4" Up to 1" 19 1,000 60,000

3" Full 1203528 DF-#14x3-PH3-E0999-B Up to 2-1/4" Up to 2" Up to 2" 24 1,000 60,000

4" Full 1203578 DF-#14x4-PH3-E0999-B 1-1/4" to 3-1/4" 1-1/4" to 3" 2" to 3" 30 1,000 60,000

5" 4' 1203605 DF-#14x5-PH3-E0999-B 1-1/4" to 4-1/4" 1-1/4" to 4" 3" to 4" 45 1,000 40,000

6" 4" 1203632 DF-#14x6-PH3-E0999-B 2-1/4" to 5-1/4" 2-1/4" to 5" 4" to 5" 46 1,000 40,000

7" 4" 1203659 DF-#14x7-PH3-E0999-B 3-1/4" to 6-1/4" 3-1/4" to 6" 5" to 6" 28 500 30,000

8" 4" 1203810 DF-#14x8-PH3-E0999-B 4-1/4" to 7-1/4" 4-1/4" to 7" 6" to 7" 31 500 30,000

9" 4" 1204081 DF-#14x9-PH3-E0999-B 5-1/4" to 8-1/4" 5-1/4" to 8" 7" to 8" 34 500 20,000

10" 4" 1202260 DF-#14x10-PH3-E0999-B 6-1/4" to 9-1/4" 6-1/4" to 9" 8" to 9" 38 500 20,000

11" 4" 1202597 DF-#14x11-PH3-E0999-B 7-1/4" to 10-1/4" 7-1/4" to 10" 9" to 10" 41 500 20,000

12" 4" 1202600 DF-#14x12-PH3-E0999-B 8-1/4" to 11-1/4" 8-1/4" to 11" 10" to 11" 45 500 20,000

* Note - Thread length measured from tip of the drill point to end of threads.

Approvals

Installation Tools: 2000–2500 rpm screw guns and #3 hardened Phillips bit. For structural concrete, 3/16" carbide bit and 1500 rpm max screw guns, or hammerdrills in the hammer mode. The standard carton package includes one #3 Phillips bit.

Options

Head: #3 Phillips Head Height: .118" max Head Dia: .448" max Thread Major Dia: .238" Shank Dia: .180"Strength (lbs ult.): Tensile: 3600 Torsional: 110 in-lbs min Shear: 2630Pull-out: (lbs avg.): 22 ga: 540 20 ga: 630 18 ga: 900 4000 psi concrete (1" penetration): 850 3/4" plywood (through penetration): 590 2x dimensional lumber (1" penetration): 605

• Can be pre-assembled to plastic Dekflat plate for insulation attachment and to seam plates for roof cover attachment.

• 10 threads per inch for ease of installation in concrete roof decks.• Low profile truss head can be used for clip attachment in

applications where head height is important.

• #3 Phillips recess provides for ultimate bit engagement.• The Dekfast reduced drill point provides for ultimate

pull-out values by producing a minimum opening. Thread engagement is superior as compared to standard drill points.

• e-coat

Membrane Plates Assemblies

Insulation Plates

12-1017.07

State of Florida: FL20311

Page 9: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

7SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

#15#3 Phillips drive, 13 tpi, drill point

For insulation and membrane attachment to wood, steel, and structural concrete roof decks

Fasteners

• Can be pre-assembled to Dekfast steel membrane plates for roof cover attachment and 3" round Dekflat for insulation attachment.

• Above average pull-out values in 24, 26 gauge metal panels.• e-coat

Application#15 Dekfast Phillips HeadInsulation board to roof deckMaterials: • Steel thickness from 26 ga (.019 in.)

through 18 ga (.045 in.): Min penetration: 3/4"

• Plywood: Min thickness 3/4" FR treated; min through penetration: 1/4"

• Wood 2x (1-1/2" thick): Min penetration: 1"

• Structural concrete: Min penetration: 1"

Use with: • Dekfast 2-7/8" hex plates• Dekfast 3" round plastic Dekflat plates• 3" round metal plates• Batten Bar• Steel membrane plates• Other attachment elements approved

by the roofing system manufacturer for use with their products

NotesDimensions are nominal inches unless noted. Steel roof decks include all FM-approved 18-20-22 ga. FM-approved wood decks include 3/4" FR plywood and 2x dimensional lumber. Structural concrete to be predrilled with standard 7/32" carbide bit to minimum 1/2" deeper than fastener penetration. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Selection Fastener *Thread Carton Carton Skid Length Length Material No. North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty.

1-1/4" Full 789566 DF-#15x1-1/4-PH3-E0999-B Up to 1/4" Up to 1/4" Up to 1/4" 13 1,000 60,000

2" 1.75" 1204935 DF-#15x2-PH3-E0999-B Up to 1-1/4" Up to 1" Up to 1" 24 1,000 60,000

3" 2.75" 789609 DF-#15x3-PH3-E0999-B Up to 2-1/4" Up to 2" 1" to 2" 30 1,000 60,000

4" 3.75" 789635 DF-#15x4-PH3-E0999-B 1-1/4" to 3-1/4" 1-1/4" to 3" 2" to 3" 42 1,000 60,000

5" 4" 789664 DF-#15x5-PH3-E0999-B 1-1/4" to 4-1/4" 1-1/4" to 4" 3" to 4" 51 1,000 40,000

6" 4" 789692 DF-#15x6-PH3-E0999-B 2-1/4" to 5-1/4" 2-1/4" to 5" 4" to 5" 30 500 30,000

7" 4" 1230686 DF-#15x7-PH3-E0999-B 3-1/4" to 6-1/4" 3-1/4" to 6" 5" to 6" 35 500 30,000

8" 4" 789740 DF-#15x8-PH3-E0999-B 4-1/4" to 7-1/4" 4-1/4" to 7" 6" to 7" 40 500 30,000

9” 4" 1297437 DF-#15x9-PH3-E0999-B 5-1/4" to 8-1/4" 5-1/4" to 8" 7" to 8" 45 500 20,000

10" 4" 789767 DF-#15x10-PH3-E0999-B 6-1/4" to 9-1/4" 6-1/4" to 9" 8" to 9" 49 500 20,000

12" 4" 789791 DF-#15x12-PH3-E0999-B 8-1/4" to 11-1/4" 8-1/4" to 11" 10" to 11" 29 250 10,000

14" 4" 789807 DF-#15x14-PH3-E0999-B 10-1/4" to 13-1/4" 10-1/4" to 13" 12" to 13" 34 250 6,000

16" 4" 789822 DF-#15x16-PH3-E0999-B 12-1/4" to 15-1/4" 12-1/4" to 15" 14" to 15" 38 250 6,000

* Note - Thread length measured from tip of the drill point to end of threads.

Head: #3 Phillips Head Height: .130" max Head Dia: .448" max Thread Major Dia: .263" Shank Dia: .204" Threads per Inch: 13Strength (lbs ult.): Tensile: 4350 Torsional: 130 in-lbs min Shear: 3700 Pull-out: (lbs avg.): 22 ga: 706 20 ga: 898 18 ga: 1140 3/4" plywood (through penetration): 703 2x lumber (1-1/2" penetration): 692 Concrete 4000 psi (1" penetration): 728Non FM Approved Decks: 26 ga: 301 24 ga: 453

Rev. A (2/2017)

Continued on following page

Page 10: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

8SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

#15#3 Phillips drive, 13 tpi, drill point

For insulation and membrane attachment to wood, steel, and structural concrete roof decks

Fasteners

Approvals

InstallationTools: 2000 – 2500 rpm screw guns and #3 hardened Phillips bit. For structural concrete, 7/32" carbide bit and 1500 rpm screw gun or hammer drill in hammer mode.

The standard carton package includes one #3 Phillips bit.

OptionsAssemblies

Installation Tools isoweld®

Membrane Plates

Insulation Plates

12-1017.07

State of Florida: FL20311

Rev. A (2/2017)

Page 11: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

9SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Insulation Plates2-7/8" hex plate, 3" round

For insulation using Dekfast #12, #12 Hex, #14, #15, Dekspike™, Deklite™, and T.P.R.

Stress Plates

ApplicationGalvalume Steel Hex Insulation PlateUse with: • #12 Dekfast• #14 Dekfast• #15 Dekfast • 1/4" Dekfast Spike• TPR

Galvalume Steel 3" Round Insulation PlateUse with: • #12 Dekfast • #14 Dekfast • #15 Dekfast • TPR

• 1/4" Dekfast Spike

Dekflat 3" Round Plastic Lock PlateFlat bottom is ideal for use with rigid board surfaces as well as standard insulation boards.Use with: • #12 Dekfast

• #14 Dekfast

• #15 Dekfast

isoweld® platesUse with:• #15 Dekfast

Contact SFS for special use applications with:• #12 Dekfast• #14 Dekfast• BS 6.1mm

• Flat bottom provides for use on rigid board surfaces.• Metal plates are stacked for ease of use.

OD: 2-7/8" Hex ID: .270" Thickness: .019" Finish: AZ50 Galvalume

OD: 3" Round ID: .260" Thickness: .019" Finish: AZ50 GalvalumeAvailable pre-assembled to Dekfast #12 Phillips

OD: 3" Round ID: .260" Material: PolypropyleneCan be pre-assembled to Dekfast #14 or #12 Phillips fasteners

OD: 3.12" Round ID: .260" Material: G90 Steel with proprietary TPO adhesive coating Color: Yellow Coating back of plate: polyester gray

OD: 3.12" Round ID: .260" Material: G90 Steel with proprietary PVC adhesive coating Color: Purple Coating back of plate: polyester gray

Weld interface surface TPO membrane to TPO plate

TPO

PVC/KEE

Weld interface surface PVC/KEE membrane to PVC plate

NotesDimensions are nominal inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Rev. A (12/2017)

Continued on following page

Page 12: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

10SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Insulation Plates2-7/8" hex plate, 3" round

For insulation using Dekfast #12, #12 Hex, #14, #15, Dekspike™, Deklite™, and T.P.R.

Stress Plates

SelectionItem Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.Galvalume Steel Hex Insulation Plate 730612 PLT-H-2-7/8-B 38 1,000 40,000

Galvalume Steel 3" Round Insulation Plate 739814 PLT-R-3-B 41 1,000 40,000

Dekflat 3" Round Plastic Lock Plate 792622 PLT-P-R-3-B 22 1,000 36,000

isoweld ® Plate - PVC 1555270 FI-P-6,8-PVC-PC 34 500 18,000

isoweld ® Plate - TPO 1555269 FI-P-6,8-TPO-PC 34 500 18,000

Approvals

InstallationUse in applications approved by the roofing system manufacturer.

Options#12 #14 #15 Assemblies Dekspike™

T.P.R. Peel Rivet

12-1017.07

State of Florida: FL20311

Rev. A (12/2017)

Page 13: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

11SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Membrane Plates 2-3/8" round, 2" roundFor membrane using #14, #15, K-fast™, Dekspike™, and T.P.R.

Stress Plates

• Engineered barb design creates maximum wind uplift rating.

• SFS intec plates are stacked for ease of fastening pattern.

ApplicationGalvalume Steel Round 2" 22-Ga Barbed PlateUse with: • #14 Dekfast• #15 Dekfast • 1/4" Dekfast Spike• TPR

Non-Barbed Galvalume 2" Round Membrane PlateUse with: • #12 Dekfast• #14 Dekfast

Galvalume Steel Round 2-3/8" 20-Ga Barbed PlateUse with: • #14 Dekfast• #15 Dekfast • 1/4" Dekfast Spike• TPR

Galvalume Steel Oval 1-1/2" x 2-3/4" 18-Ga Barbed PlateUse for PVC membrane with: • #14 Dekfast• #15 Dekfast • #12 Purlin

NotesDimensions are nominal inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

OD: 2" ID: .265/.270" Thickness: .032" Finish: AZ55 Galvalume

OD: 2-3/8" ID: .260/.262" Thickness: .038" Finish: AZ50 Galvalume

OD: 2" Round ID: .255" Thickness: .032" Finish: AZ55 Galvalume

Lenth: 2.750"Width: 1.500" ID: .250" Thickness: .048" Finish: AZ50 Galvalume

Continued on following page

Page 14: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

12SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Membrane Plates 2-3/8" round, 2" roundFor membrane using #14, #15, K-fast™, Dekspike™, and T.P.R.

Stress Plates

SelectionItem Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.

Galvalume Steel Round 2", 22-Ga Barbed Plate 298312 PLT-R-2-4B-B 29 1000/pail 40,000

Non-Barbed Galvalume 2" Round Membrane Plate 727658 PLT-R-2-B 34 1000/pail 50,000

Galvalume Steel Round 2-3/8", 20-Ga Barbed Plate 982326 PLT-R-2-3/8-6B-B 36 1000/pail 24,000

Galvalume Steel Oval 1-1/2" x 2-3/4", 18-Ga Barbed Plate 1274909 PLT-02-3/4-12B-B 12 500/pail 20,000

Approvals

InstallationUse in applications approved by the roofing system manufacturer.

Options#14 #15 Assemblies

Belted Systems

T.P.R. Peel Rivet

12-1017.07

State of Florida: FL20311

Page 15: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

13SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

#12 Purlin Fastener#3 square drive, drill point

For retro-fit roofing systems where heavy gauge purlin material must be penetrated

Specialty Fastening

• Shank diameter is smaller than that of the drill point and the outside thread diameter, allowing thick metal to be drilled and cleared of chips before threads tap into metal.

• 24 threads per inch allow for easier driving of the fastener and greater pull-out values.• e-coat

ApplicationDekfast #12 Purlin FastenersUp to 1/4" purlin steelMaterials: • Steel thickness: 18 ga (.045" nominal)

through 1/4" (.250")

NotesDimensions are nominal inches unless noted.

* Denotes tensile failure of fastener (fastener failed in tensile before pulling out of tabulated substrate). Fasteners are designed for the attachment of roofing materials to purlins. Designated holding values depend on the quality of materials to which the fastener is being anchored. Pull-out tests need to be conducted to verify that the substrate provides adequate pull-out values.

Selection Fastener *Thread Pilot Composite Carton Carton Skid Length Length Length Material No. North American Code Thickness Wt. (lbs) Qty. Qty.12 x 3-3/4" 3.375" 0.750" 1202224 PUR-#12x3-3/4-PC-SQ3-E0999-B Up to 2-3/4" 33 1000 60,000

12 x 4-3/4" 3.375" 0.750" 1202226 PUR-#12x4-3/4-PC-SQ3-E0999-B 1-1/4" to 3-3/4" 41 1000 40,000

12 x 5-3/4" 3.375" 0.750" 1202228 PUR-#12x5-3/4-PC-SQ3-E0999-B 2-1/4" to 4-3/4" 48 1000 40,000

12 x 6-3/4" 3.375" 0.750" 1202230 PUR-#12x6-3/4-PC-SQ3-E0999-B 3-1/4" to 5 3/4" 28 500 30,000

* Note - Thread length measured from tip of the drill point to end of threads.

InstallationTools: 1800 – 2500 rpm screw gun equipped with depth-sensing nosepiece.

The standard carton package includes one #3 square bit.

Head: #3 square, pancake head Head Height: .110" Head Dia: .445" Thread Major Dia: .207" Shank Dia: .179" nomStrength (lbs ult.): Tensile: 2300 Torsional: 100 in-lbs minPull-out: (lbs avg.): 18 ga (.045): 375 16 ga (.060): 599 14 ga (.075): 869 12 ga (.104): 1477 3/16" (.188): 2300* 1/4" (.250): 2300*

Optionsisoweld®

Pilot Length

ThreadLength

Page 16: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

14SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Insulation Panel Fastener #14 #3 square drive, drill pointFor use in vented and/or composite nailboard applications

Specialty Fastening

• Flat profile head for flush engagement to the nailboard.• No plates necessary.

• 5/8" oversized head reduces fastener patterns.• e-coat

ApplicationInsulation Panel Fasteners#14 #3 square drive, drill pointMaterials: • Dimensional wood 2x (1-1/2" thick):

Min penetration: 1" • Steel thickness: 22-20-18 ga:

Min penetration: 3/4"

NotesDimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon specific wood density variation. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

SelectionFastener Length *Thread Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.

2-5/8" 1.5" 1119456 IPF-#14x2-5/8-PC-SQ3-E0999-B 15 500 30,000

3" 1.5" 1119468 IPF-#14x3-PC-SQ3-E0999-B 16 500 30,000

3-1/2" 3" 1119481 IPF-#14x3-1/2-PC-SQ3-E0999-B 18 500 30,000

4" 3" 1119482 IPF-#14x4-PC-SQ3-E0999-B 21 500 30,000

4-1/2" 3" 1119484 IPF-#14x4-1/2-PC-SQ3-E0999-B 23 500 30,000

5" 3" 1119486 IPF-#14x5-PC-SQ3-E0999-B 25 500 30,000

5-1/2" 3" 1119494 IPF-#14x5-1/2-PC-SQ3-E0999-B 27 500 30,000

6" 3" 1119495 IPF-#14x6-PC-SQ3-E0999-B 29 500 30,000

6-1/2" 3" 1119497 IPF-#14x6-1/2-PC-SQ3-E0999-B 31 500 30,000

7" 3" 1119501 IPF-#14x7-PC-SQ3-E0999-B 33 500 30,000

7-1/2" 3" 1119505 IPF-#14x7-1/2-PC-SQ3-E0999-B 34 500 30,000

8" 3" 786137 IPF-#14x8-PC-SQ3-E0999-B 18 250 15,000

8-1/2" 3" 1119513 IPF-#14x8-1/2-PC-SQ3-E0999-B 20 250 15,000

9" 3" 1119516 IPF-#14x9-PC-SQ3-E0999-B 20 250 10,000

10" 3" 1119539 IPF-#14x10-PC-SQ3-E0999-B 23 250 10,000

* Note - Thread length measured from tip of the drill point to end of threads.

InstallationInstall fasteners with self-drill fastener installation tool or drill using caution to avoid fastener strip out.

The standard carton package includes one #3 square drive bit.

Head: #3 square drive Head Dia: .645" – .620" Head Height: .078" – .072" Thread Major Dia: .245" Shank Dia: .190"Strength (lbs ult.): Tensile: 3500 Shear: 2700 Torque: 125 in-lbsPull-out (1" penetration) (lbs avg.): Face Grain: 823 Edge Grain: 845 1-1/2" Penetration: Face Grain: 1344 Edge Grain: 1320 Grade E steel deck: 22 ga (.030): 498

Page 17: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

15SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

#14 Stainless#14, 13 tpi, drill point

For the attachment of insulation and membrane roof covers in a corrosive environment

Specialty Products

ApplicationDekfast #14 Stainless SteelAttachment of insulation and/or roof covers in mild to light industrial environmentsMaterials: • Steel thickness from 22 ga (.028 in.)

through 18 ga (.045 in.): Min penetration: 3/4"

• Plywood: Min thickness: 3/4"• FR treated: Min penetration: 1/4"• Wood 2x: (1-1/2" thick): Min penetration 1"Use with: • Stress plates• Batten Bar• Other attachment elements approved by the roofing system manufacturer for use with its productsSteel roof decks include all FM approved 18-20-22 ga

NotesDimensions are nominal inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Selection Fastener *Thread Carton Carton Skid Length Length Material No. North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty.

1-1/2" Full 791371 DF-S4-#14x1-1/2-PH3-B Up to 3/4" Up to 1/2" Up to 1/2" 14 1,000 60,000

2" Full 791373 DF-S4-#14x2-PH3-B Up to 1-1/4" Up to 1" 1/2" to 1" 18 1,000 60,000

3" 2.875" 791376 DF-S4-#14x3-PH3-B 3/8" to 2-1/4" Up to 2" 1-1/2" to 2" 25 1,000 40,000

4" 3.875" 791379 DF-S4-#14x4-PH3-B 3/8" to 3-1/4" Up to 3" 2-1/2" to 3" 32 1,000 40,000

5" 3.875" 791381 DF-S4-#14x5-PH3-B 1-3/8" to 4-1/4" 1-3/8" to 4" 3-1/2" to 4" 39 1,000 40,000

6" 3.875" 791383 DF-S4-#14x6-PH3-B 2-3/8" to 5-1/4" 2-3/8" to 5" 4-1/2" to 5" 46 1,000 40,000

7" 3.875" 791385 DF-S4-#14x7-PH3-B 3-3/8" to 6-1/4" 3-3/8" to 6" 5-1/2" to 6" 27 500 30,000

8" 3.875" 791387 DF-S4-#14x8-PH3-B 4-3/8" to 7-1/4" 4-3/8" to 7" 6-1/2" to 7" 30 500 30,000

10" 3.875" 791389 DF-S4-#14x10-PH3-B 6-3/8" to 9-1/4" 6-3/8" to 9" 8-1/2" to 9" 39 250 20,000

12" 3.875" 1298264 DF-S4-#14x12-PH3-B 8-3/8" to 11-1/4" 8-3/8" to 11" 10-1/2" to 11" 48 250 20,000

* Note - Thread length measured from tip of the drill point to end of threads.

Approvals

InstallationTools: 2000–2500 rpm screw guns and #3 hardened Phillips bit.

The standard carton package includes one #3 Phillips bit.

OptionsDekfast stainless fasteners must be used with the following plates or other attachment elements approved by the roofing systems manufacturer for use with their products: 3" round plastic plate (792622).

Head: #3 Phillips Truss head Head Height: .118" max Head Dia: .440" max Thread Major Dia: .235" Shank Dia: .180"Pull-out: (lbs avg.): 24 ga: 325 22 ga: 470 20 ga: 635 18 ga: 815 Plywood (3/4" thick): 495

• 400 series stainless steel is a magnetic heat-treatable stainless steel

• Type 410 self-drilling fasteners provide fair resistance to corrosion in mild to light industrial environments.

Membrane Plates

Insulation Plates

State of Florida: FL20311

Page 18: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

16SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

isotak® Thermal break fastening system

For attachment of membrane and insulation reducing thermal bridging

Specialty Fastening

• Guards against fastener thermal bridging• Ideal for low slope roof and cold storage construction• Cost savings through energy conservation

• Lower cost alternative for attaching thick roof assemblies• Factory Mutual approved

Applicationsisotak® System

Materials: • #14 isotak® fastener • Polypropylene sleeve for insulation attachment

The combination of sleeve and fastener length will determine the minimum and maximum build-up thickness the system can accommodate, with a maximum thickness up to 18"

NotesDimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

SelectionFastener Length Material No. Code Carton Wt. (lbs) Carton Qty.2-3/8" 1185063 BS-6.1/52x60 9 500

4" 1185059 BS-6.1/91x100 14 500

6" 1193134 BS-6.1/141x150 21 500

7-7/8" 1193137 BS-6.1/192x200 28 500

Sleeve Length Material No. Code Carton Wt. (lbs) Carton Qty.4-1/8" 1037836 R75x105 23 500

5-1/4" 1037838 R75x135 26 500

6-1/2" 1037839 R75x165 13 250

8-7/8" 1037842 R75x225 16 250

10" 1037843 R75x255 18 250

11-1/4" 1037844 R75x285 15 200

Approvals

InstallationFor ease of installation, special drive shafts and driving tools are available.

FastenerFastener Head: Countersunk head, drive T25Fastener Head Dia: 0.358"Thread Major Dia: 0.240"

SleeveMaterial: Polypropylene, PPPlate Dia: 3" RoundShank Dia: 0.590

Pull-out (lbs. avg.):22 ga: 57320 ga: 66018 ga: 1005

State of Florida: FL20311

Page 19: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

17SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Deklite™Nylon reinforced fiberglass auger

For lightweight roof decks: lt. wt. concrete, Tectum™, and gypsum, for insulation and membrane attachment

Specialty Fastening

• Deklite tapered root progressively compacts the material making the deck denser around the root, increasing pull-out values.

• Auger locks to plate upon installation. • Tapered design also yields 70% more surface area leading to a greater holding power.

ApplicationDeklite Non-penetrating Nylon FastenerMaterials: Lightweight insulating concrete, poured gypsum, gypsum plank, TectumMin penetration: 1-1/2"

Deklite Galvalume Steel 2" Round Seam PlateOD: 2" Thickness: .032" Finish: AZ55 Galvalume

Deklite Galvalume Steel 3" Round Insulation PlateOD: 3" Thickness: .017" Finish: AZ55 Galvalume

NotesDimensions are nominal inches unless noted. Due to density differences in light weight insulating concretes, Tectum, and gypsum type roof decks, conducting field pull-out testing is recommended. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Head OD: 1" Head Height: 1/8" Insert Size: 1/4" square drive Fixture Clearance Hole: 5/8" Fixture clearance holes are needed only when plywood or other rigid materials are fastened to a roof deck.

Continued on following page

Page 20: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

18SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Deklite™Nylon reinforced fiberglass auger

For lightweight roof decks: lt. wt. concrete, Tectum™, and gypsum, for insulation and membrane attachment

Specialty Fastening

SelectionLength Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.2" 792776 DLx2-SQ1/4-B 14 500 31,500

2-1/2" 792778 DLx2-1/2-SQ1/4-B 15 500 22,500

3" 792780 DLx3-SQ1/4-B 17 500 22,500

3-1/2" 792782 DLx3-1/2-SQ1/4-B 18 500 22,500

4" 792784 DLx4-SQ1/4-B 19 500 13,500

4-1/2" 792786 DLx4-1/2-SQ1/4-B 21 500 13,500

5" 792788 DLx5-SQ1/4-B 22 500 9,000

5-1/2" 792790 DLx5-1/2-SQ1/4-B 23 500 9,000

6" 792792 DLx6-SQ1/4-B 25 500 9,000

6-1/2" 792794 DLx6-1/2-SQ1/4-B 26 500 9,000

7" 792796 DLx7-SQ1/4-B 14 250 6,750

7-1/2" 792798 DLx7-1/2-SQ1/4-B 15 250 6,750

8" 792800 DLx8-SQ1/4-B 16 250 6,750

8-1/2" 792802 DLx8-1/2-SQ1/4-B 17 250 6,750

9" 792804 DLx9-SQ1/4-B 17 250 4,500

9-1/2" 792806 DLx9-1/2-SQ1/4-B 17 250 4,500

10" 792807 DLx10-SQ1/4-B 18 250 4,500

11” 792809 DLx11-SQ1/4-B 19 250 4,500

12” 792810 DLx12-SQ1/4-B 21 250 4,500

13” 792811 DLx13-SQ1/4-B 22 250 4,500

Deklite Stress PlatesLength Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.2" Stress Plate 792743 PLT-DL-R-2-4B-B 18 500 4,500

3"’ Stress Plate 792745 PLT-DL-R-3-4B-B 18 500 4,500

PerformanceBase Material Pre-Drill Embedment Tension LoadTectum Deck — 1-1/2 " 280 lbs

Tectum Deck — 2" 440 lbs

Tectum Deck — 2-1/2" 595 lbs

3" Insulrock 5/16" 2-1/2" 365 lbs

Poured Gypsum 3/8" 2" 540 lbs

Notes: Load capacities are based on testing conducted according to ASTM Standard E 488. Test data above represent average ultimate loads sustained in the materials indicated and should be used as guidelines only. Job site tests are recommended. Tectum is a registered trademark of Tectum, Inc.

Approvals

InstallationTools: Impact wrench or hammer drills in the hammer mode.

The standard carton package includes one 1/4" square drive bit.

12-1017.07

State of Florida: FL20311 *Deklite fasteners not included.

Page 21: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

19SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Dekspike™1/4" mushroom head

For insulation and membrane attachment to structural concrete roof decks

Specialty Fastening

• Compresses at 3 contact points to match the tolerance of the drilled hole.

• Can withstand dynamic loads induced by wind loading.• e-coat

ApplicationsDekspike Structural Concrete Roofing AnchorMaterials: • Structural concrete:

Min penetration: 1-1/4" (Min penetration for 1-1/4" length: 7/8")

Composition thickness range of Dekspike 1-1/2" through 16": Anchor length less 1-1/4" (Min embedment: 1-1/4") Composition thickness range of Dekspike 1-1/4": 3/8" (Min embedment: 7/8")Min FM approved insulation board for concrete application: 1/2" Min FM approved penetration: 1-1/4" Shortest FM approved length for insulation attachment: 2"Use with: • Batten Bar• Steel insulation plates• Steel membrane plates

NotesDimensions are nominal inches unless noted. Tension strength (pull-out) based on 1-1/4" embedment depth and 2500 psi concrete. Pull-out strength is 1100 lbs ult. in 2500 psi concrete (FM J.I. No. 0Y0A8.AM) at 1-1/4" penetration depth. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

SelectionLength Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.1-1/4" 792840 SPK-#14x1-1/4-E0999-B 11 500 60,000

1-1/2" 792841 SPK-#14x1-1/2-E0999-B 11 500 60,000

2" 792842 SPK-#14x2-E0999-B 16 500 60,000

2-1/2" 792843 SPK-#14x2-1/2-E0999-B 21 500 42,000

3" 792844 SPK-#14x3-E0999-B 22 500 18,000

3-1/2" 792845 SPK-#14x3-1/2-E0999-B 25 500 18,000

4" 792846 SPK-#14x4-E0999-B 31 500 18,000

4-1/2" 792847 SPK-#14x4-1/2-E0999-B 31 500 18,000

5" 792850 SPK-#14x5-E0999-B 35 500 18,000

5-1/2" 792853 SPK-#14x5-1/2-E0999-B 36 500 18,000

6" 792856 SPK-#14x6-E0999-B 20 250 21,000

7" 792860 SPK-#14x7-E0999-B 23 250 21,000

7-1/2" 792861 SPK-#14x7-1/2-E0999-B 26 250 21,000

8" 792864 SPK-#14x8-E0999-B 28 250 21,000

9" 792868 SPK-#14x9-E0999-B 30 250 9,000

10" 792870 SPK-#14x10-E0999-B 33 250 4,500

11" 792872 SPK-#14x11-E0999-B 14 100 8,000

12" 792874 SPK-#14x12-E0999-B 15 100 8,000

13" 792875 SPK-#14x13-E0999-B 16 100 5,000

14" 792878 SPK-#14x14-E0999-B 17 100 5,000

Head: Mushroom Head Head Height: .120" max Head Dia: .500" max Shank Dia: .239"Strength (lbs ult.): Tensile (at 1-1/4" embedment): 1100Pull-out: (lbs avg.): 4000 psi (1-1/4" penetration): 1550

Continued on following page

Page 22: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

20SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Dekspike™1/4" mushroom head

For insulation and membrane attachment to structural concrete roof decks

Specialty Fastening

Approvals

InstallationTools: ANSI 1/4" diameter (.268 – .260 dia) drill bit. Drill hole depth at least 1/2" beyond the anticipated embedment depth. Clean the hole and drive Dekspike flush against the plate or material being fastened.

OptionsTermination Product

Membrane Plates

Insulation Plates

12-1017.07

State of Florida: FL20311

Page 23: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

21SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

ZAC® Anchors 3/8" HWH termination fastenerFor fastening termination bar at wall terminations

Specialty Fastening

• Term bar fastener that can be backed out.• Threads into wood, masonry, concrete and metal.• ZAC cap is zinc aluminum composition and will never

red rust.

• Can be removed and re-engaged for roof repairs without damage to the roof system.

• e-coat coating on thread.

ApplicationZAC AnchorUse with: Wood, masonry, concrete, and steel at roof wall terminations.

NotesDimensions are nominal and in inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Performance Load Capacities (2000 psi concrete)Pre-Drill 7/32" 7/32" 7/32" Embed. Depth 1" 1.25" 1.375"

Tension Load (lbs) 620 810 905

Shear Load (lbs) 830 1130 1280

Notes: All load values listed are ultimate load capacities and are not allowable load capacities. These loads should be reduced by an appropriate safety factor of at least 4 to determine the allowable load.

SelectionDia and Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.#14 x 1-3/8" HWH ZAC Anchor 792897 ZA-#14x1-3/8-HW3/8-N-E0999-C 25 1000 60,000

Notes: Load capacity is related to embedment depth. Select anchor length to provide needed embedment depth for the installed anchor.

InstallationTools: Carbide-tipped masonry drill bit sized slightly larger than nominal diameter to allow clearance.

Head: 3/8" AF ZAC HWH Long Life Dia: #14 (.248)

OptionsTermination Product

Page 24: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

22SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Zinc Nailins Termination fastenerFor fastening termination bar at wall terminations

Specialty Fastening

• Long life coatings and composition prevent corrosion.

ApplicationZinc NailinUse with: Concrete, block, brick and stone

NotesDimensions are nominal inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Performance Load Capacities (4000 psi concrete)Diameter 3/16" 1/4" 1/4" 1/4" 1/4" 1/4"Embed. Depth 3/4" 5/8" 7/8" 1-1/8" 1-3/8" 1-7/8"

Tension Load (lbs) 500 600 820 960 1150 1300

Shear Load (lbs) 1000 1500 1500 1500 1500 1500

Notes: All load values listed are ultimate load capacities and are not allowable load capacities. These loads should be reduced by an appropriate safety factor of at least 4 to determine the allowable load.

SelectionDia and North Inner Carton Carton Skid

Length Material No. American Code Nail Box Qty. Wt. (lbs) Qty. Qty.3/16 x 7/8" 792879 ZNI-3/16x7/8-C Plated Steel 100 5 500 60,000

1/4 x 3/4" 792880 ZNI-1/4x3/4-C Plated Steel 100 8 500 60,000

1/4 x 1" 792881 ZNI-1/4x1-C Plated Steel 100 10 500 60,000

1/4 x 1-1/4" 792882 ZNI-1/4x1-1/4-C Plated Steel 100 12 500 60,000

1/4 x 1-1/2" 792884 ZNI-1/4x1-1/2-C Plated Steel 100 13 500 60,000

1/4 x 2" 792885 ZNI-1/4x2-C Plated Steel 100 16 500 60,000

Notes: Load capacity is related to embedment depth. Select anchor length to provide needed embedment depth for the installed anchor. The 1-1/4" length is popular for 1/8" composite thickness applications resulting in 1-1/8" embedment.

InstallationTools: Carbide-tipped masonry drill bit sized slightly larger than nominal diameter to allow clearance. A 3/16" nominal masonry drill bit is actually .198" – .206" dia. A 1/4" nominal size is actually .260" – .268" dia.

Procedure: Position the fixture and drill a hole the same diameter as the zinc nail-in (3/16" or 1/4"). Insert the anchor and tap gently against the fixture to be fastened. Drive the nail flush to the anchor head to expand the anchor.

Head: Mushroom Dia: 3/16" and 1/4" Body: Zamac 7

OptionsTermination Product

Page 25: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

23SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Base Ply/Twin Loc-Nail FastenersBase Sheet Attachment

Base Sheet, Recovery Board and InsulationAttachment to Concrete, Wood Fiber and Poured Gypsum

• Non-threaded fastener• Precision formed from coated steel to prevent corrosion

ApplicationFM90 and FM75Base sheet attachment to higher density/LightweightInsulation Concrete

Fastener anchors itself in its own hole. No pre-drilling required.

Twin Loc-Nail Base sheet, recovery board andinsulation to lightweight insulationconcrete, structural wood fiber andpoured Gypsum.

Tube shape easily penetrates decking and existing membrane.First impact sets tube, secondimpact actuates staple.Should always be embedded intothe structural roof deck to a depthof at least 1"

NotesFastener density and spacing vary depending on applicable uplift requirements. Local codes, governing approval boadies, membrane manufacturers and individual roof deck manufacturers may have specific requirements that need to be addressed prior to beginning roofing project.

Plate Dia.: 2.7"Leg Length FM-90: 1.7" FM-75: 1.2"

Pull-out value dependent on substrate. On-site pull testing should be performed prior to roofing.

Plate Dia.: 2.7"Tube Length: 1.4", 1.8", 2.8", 3.8" and 4.8"

Pull-out value dependent on substrate. On-site pull testing should be performed prior to roofing.

Selection Material No. Carton

Product Base Ply Fast North American Code Carton Wt. (lbs) Qty.Dekfast/FM90 - 1.7" Assembled 501347 BP-2.7x1.7-B 40 1000

Dekfast/FM75 - 1.2" Assembled 501346 BP-2.7x1.2-B 36 1000

Twin Loc-Nail 1.4" 792822 TLN-2.7x1.4-B 27 500

Twin Loc-Nail 1.8" 792823 TLN-2.7x1.8-B 28 500

Twin Loc-Nail 2.8" 792824 TLN-2.7x2.8-B 34 500

Twin Loc-Nail 3.8" 792825 TLN-2.7x3.8-B 42 500

Twin Loc-Nail 4.8" 792826 TLN-2.7x4.8-B 27 250

Tools Material No. North American Code Carton Wt.(lbs) Carton Qty.Magnetic Drive 792819 TOOL-Magnetic Driver Tool 23 1

Magnetic Twin Lock Driver Tool 792821 TOOL-Magnetic Twin Loc Driver Tool 5 1

InstallationTo ensure proper installation, use the Dekfast Magnetic Driver for FM-90 and FM-75 product. Use the Twin Loc Driver to install the Twin Loc-Nail.

Consult Factory Mutual, Underwriters Lab or Miami-Dade requirements for recommended pattern in normal, exposed and hurricane areas.

Specialty Fastening

Page 26: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

24SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Termination and Batten Bars .050", .075", .090", .100", .125", 6" OCFor wall termination applications

Specialty Fastening

• Manufactured from specially extruded aluminum without sharp edges.

• Reinforced strengthening ribs allow for use in high wind applications.

ApplicationRibbed Term Bar w/ LipUse with: • #14 Dekfast Fastener• #15 Dekfast Fastener• Zac Anchor• Zinc Nailin• Dekspike™

Ribbed Term Bar Use with: • #14 Dekfast Fastener• #15 Dekfast Fastener• Zac Anchor• Zinc Nailin• Dekspike

Lip & Ball Term BarUse with: • #14 Dekfast Fastener• #15 Dekfast Fastener• Zac Anchor• Zinc Nailin• Dekspike

Gravel Stop/Drain BarUse with: • #14 Dekfast Fastener• #15 Dekfast Fastener• Zac Anchor• Zinc Nailin• Dekspike

NotesDimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Dimensions: .050" (edge) x .075" (ribs) x 1" wide x 10’ longHoles: .260" x .380" slotted at 6" O.C. spacingMaterial: Extruded Aluminum

Dimensions: .075 (edge) x .100" (ribs) x 1" wide x 10’ longHoles: .260" x .380" slotted at 6" O.C. spacingMaterial: Extruded Aluminum

Dimensions: .088" x 1" wide x 10' longHoles: .280" x .380" slotted at 6" O.C. spacingMaterial: Extruded Aluminum

Dimensions: .110" x 3.50" wide x 10' longDrainage Holes: .300" x 1.62" slotted at 4" O.C. spacingFastener Holes: .25" x .625" slotted at 6" O.C. spacingMaterial: Extruded Aluminum

Continued on following page

Page 27: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

25SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Termination and Batten Bars .050," .075", .090," .100", .125," 6" OCFor wall termination applications

Specialty Fastening

Selection Material No. Carton Hole

Termination Product Termination North American Code Wt. (lbs) Spacing Carton Qty. Skid Qty..050" All Purpose 791391 TB-AP-.05x1x120-6o.c.-TUBE 45 6" 500 feet (50-10 ft pcs) 10,000

.075" Single Lip 791394 TB-SL-.075x1x120-6o.c.-TUBE 51 6" 500 feet (50-10 ft pcs) 10,000

.075" Ribbed Single Lip 791395 TB-RSL-.075x1x120-6o.c.-TUBE 51 6" 500 feet (50-10 ft pcs) 10,000

.100" Single Lip 791401 TB-SL-.1x1x120-6o.c.-TUBE 68 6" 500 feet (50-10 ft pcs) 10,000

.125" Flat 791403 TB-F-.125x1x120-6o.c.-TUBE 78 6" 500 feet (50-10 ft pcs) 10,000

.100" Ribbed Term Bar Flat 791404 TB-R-.1x1x120-6o.c.-TUBE 78 6" 500 feet (50-10 ft pcs) 10,000

Drain Bar/Gravel Stop 791410 TB-DB-.125X3.5x120-TUBE 42 6" 100 feet (10-10 ft pcs) 10,000

.090" Lip and Ball 791411 TB-LB-0.09-TUBE 86 6" 500 feet (50-10 ft pcs) 10,000

Flat Batten Bar (.050) 625833 TB-FBB-.05x1x120-6o.c.-TUBE 45 6" 500 feet (50-10 ft pcs) 10,000

Coiled Batten Bar (.260) 791434 BB-R-.08x.99x100-3o.c.-CTN 72 3" 500 feet (50-10 ft pcs) 10,000

ApprovalsTermination products meet Factory Mutual corrosion-resistance Standard 4470.

OptionsZAC® Anchors & Nailins

Page 28: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

26SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

isofast® Insulation attachment using #12 Dekfast

Roof Top ProductivityTools & Systems

#12 Belted Fasteners Collated fasteners for insulation attachmentMaterials: • Steel thickness from 22 ga (.028 in.)

through 18 ga (.045 in.): Min penetration: 3/4"

• Wood 2x: (1-1/2" thick): Min penetration 1"

Use with: • IFC/PH 70x70 (2-3/4" x 2-3/4")

Galvalume stress plates

• IF/IG-C 82x40 (3-1/4" x 1-1/2") Galvalume stress plates

Steel roof decks include all FM approved 18-20-22 ga

NotesDimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

SelectionLength Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.2-1/4" 785705 DF-#12x2-1/4-PH3-E0999-BL 13 750 52,500

2-7/8" 785724 DF-#12x2-7/8-PH3-E0999-BL 16 750 52,500

3-1/4" 785746 DF-#12x3-1/4-PH3-E0999-BL 17 750 52,500

3-3/4" 785770 DF-#12x3-3/4-PH3-E0999-BL 20 750 52,500

4-1/2" 785787 DF-#12x4-1/2-PH3-E0999-BL 23 750 33,750

5" 785804 DF-#12x5-PH3-E0999-BL 26 750 33,750

6" 785813 DF-#12x6-PH3-E0999-BL 31 750 33,750

7" 1296243 DF-#12x7-PH3-E0999-BL 36 750 33,750

8” 1296248 DF-#12x8-PH3-E0999-BL 41 500 15,000

IF-L-70 x 70 Insulation PlateUse with: • #12 Belted Fasteners

SelectionDescription Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.2-3/4" Square 735650 PLT-S-2-3/4x2-3/4-BL 41 750 40,500

Approvals

Head Drive: #3 Phillips Head Height: Max .118" Head Dia: Max .448" Thread Major Dia: .222" Shank Dia: .167"Strength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815Pull-out (lbs avg.): Steel: 22 ga: 513 20 ga: 695 18 ga: 787 2x dim. lumber (1" penetration): 462 Plywood 3/4" thick (through penetration): 575

ApplicationFastener length 2-1/4" - 6" isofast IF 160 tool Material no: 1349029

• 3x faster installation • Stand-up operation reduces back strain and fatigue.

Fastener length 2-1/4" - 8" isofast IF 240 tool

Material no: 1349071

OD: 2-3/4" x 2-3/4" Square ID: .257" Thickness: .019" Finish: AZ50 Galvalume

12-1017.07

State of Florida: FL20311

Page 29: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

27SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

isofast® Membrane attachment using #15 Dekfast

Roof Top ProductivityTools & Systems

ApplicationFastener length 2" - 6" isofast IF 160 tool Material no: 1349028 Application#15 Belted FastenersCollated fasteners for membrane attachmentMaterials:• Steel thickness from 26 ga (.019 in.)

Through 18 ga (.045 in.): Min penetration: 3/4"

• Wood 2x (1-1/2" thick): Min penetration 1"

Use with:• IF-2.375-AT (2-3/8") stacked

Galvalume stress plates• IF-82x50-AT (3-1/4" x 1-1/2") stacked

Galvalume stress platesSteel roof decks include all FM approved 18-20-22 ga

NotesDimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

SelectionLength Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.2" 1297395 DF-#15x2-PH3-E0999-BL 21 1000 42,000

3" 1297401 DF-#15x3-PH3-E0999-BL 31 1000 30,000

4" 1060285 DF-#15x4-PH3-E0999-BL 21 500 21,000

5" 1297411 DF-#15x5-PH3-E0999-BL 25 500 15,000

6" 1297420 DF-#15x6-PH3-E0999-BL 30 500 15,000

7" 1297427 DF-#15x7-PH3-E0999-BL 35 500 15,000

8” 1297433 DF-#15x8-PH3-E0999-BL 39 500 15,000

9” 1297438 DF-#15x9-PH3-E0999-BL 44 500 15,000

IF-2.375-AT Membrane PlateUse with: • #15 Belted Fasteners

SelectionDescription Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty.2-3/8" Round 792759 PLT-R-2-3/8-BL 41 500 27,000

Approvals

Head Drive: #3 Phillips Head Height: Max .130" Head Dia: Max .448" Thread Major Dia: .263" Shank Major Dia: .204" Threads per Inch: 13Strength (lbs ult.): Tensile: 4350 Torsional: 130 in-lbs min Shear: 3700Pull-out (lbs avg.): Steel: 22 ga: 706 20 ga: 898 18 ga: 1140 Plywood 3/4" thick (through penetration): 703 Wood 2x (1-1/2" penetration): 692 Non-FM approved decks: 26 ga: 301 24 ga: 453

• 3x faster installation • Stand-up operation reduces back strain and fatigue.

Fastener length 2" - 9" isofast IF 240 tool

Material no: 1349030

OD: 2 3/8" Round ID: .265" Thickness: .042" Finish: AZ50 Galvalume®

12-1017.07

State of Florida: FL20311

Page 30: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

28SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

isoweld®Induction Welding System

Innovative induction welding system which welds adhesive coated plates to single ply membranes

Roof Top ProductivityTools & Systems

• 1-step calibration• Hand-held inductor• Constant monitoring of membrane surface temperature• "x2" welding - two membrane thickness

• 3-way weld verification • Plate-finding search function• No "false positive" welds

Applicationisoweld® System

• PVC and TPO single ply membrane: 35-90 mils• Polyiso insulation• High density cover boards• EPS insulation• Foil faced insulation• Mineral wool insulation• Parapet wall welding

Additional Components Hand-Held inductor

Contents included in shipping/storage case:

1 - isoweld® 3000 stand-up tool1 - calibration template5 - replacement protective pads for inductor1 - instruction manual1 - plunger cup

Magnets and magnets in case (set of 6 or 12)

#15 Dekfast Fastener

TPO Plate (500/plastic pail)

PVC Plate (500/plastic pail)

Pad for EPS/XPS application

Installation Tool

Selection

Technical Data Approvals

Dimensions & Weightisoweld® 3000 - 43"H x 21"W x 16"Disoweld® 3000 - 37"L x 23"W x 24"D (in case)isoweld® 3000 - 42 lbs.; 80 lbs. (in case)Magnets, set of 6 or 12 - 35"L x 24"W x 14"D (in case)Magnet, single - 2.7 lbs.Magnet, set of 6 - 40 lbs., set of 12 - 57 lbs. (in case)Hand-held inductor cable length - 13' Plates, 500 pc. plastic pail - 9-7/8" x 9-7/8" x 4-3/8"; 34 lbs

Electrical - minimum requirements*:Voltage: 110V (50-60 Hz) /230VCurrent: 20 amp, GFI protectionPower: 5000 W generator, dedicated12AWG/3 power extension cord100' maximum length of power extension cord

*Power cords of larger conductor size (10AWG/3) and shorter length are

recommended for optimal performance.

Recommended Application Limits:Temperature: 23ºF - 122ºFSlope: <10º

12-1017.07

State of Florida: FL20311

System Material No. Material No.Component Sell Rental

isoweld® 3000 1543691 1351200

Hand inductor 1345222 1355217

Magnets (set of 6) 1550566 –

Magnets (set of 12) 1550564 –

Magnets (set of 10) – 1355216

#15 Dekfast fastener Length Dependent N/A

TPO Plate (500/plastic pail) 1555269 N/A

PVC Plate (500/plastic pail) 1555270 N/A

Installation tool 1336394 N/A

Pad for EPS/XPS application 1351805 N/A

Rev. B (12/2017)

Page 31: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

29SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

TPR-L Peel Rivet System Two-piece, aluminum magnesium alloy fastenerFor insulation and membrane attachment to problematic roof decks

Roof Top ProductivityTools & Systems

• For use in decks where threaded fasteners cannot achieve required pull-out values.• Provides improved pull-out values in light gauge or problematic steel decks.• Corrosion-resistant components for corrosive building environments.

ApplicationTPR-L Peel RivetFor insulation and membrane attachment to problematic decksMaterials: • Steel: Min penetration: 1"• Woodfiber: Min penetration: 1"• Wood: Min penetration: 1"• Lightweight Concrete:

Min penetration: 1"Use with: • 2" or 3" round Galvalume stress plates• 2-7/8" hex Galvalume stress plates

NotesDimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

Selection Recommend Minimum Maximum Carton Carton

Length Clamping Length Clamping Length Material No. North American Code Wt. (lbs) Qty. Skid Qty.1-1/2" 1/2" 1/2" 1241233 TPR-L-6,3x38 Peel Rivet 21 1,000 16,0000

2" 1/2" 1" 1326232 TPR-L-6,3x 51 Peel Rivet 25 1,000 16,0000

3" 7/8" 2" 1241241 TPR-L-6,3x 76 Peel Rivet 17 500 16,0000

4" 1-5/8" 3" 1241244 TPR-L-6,3x102 Peel Rivet 21 500 16,0000

5" 2-5/8" 4" 1241246 TPR-L-6,3x127 Peel Rivet 25 500 16,0000

6" 3-5/8" 5" 1241248 TPR-L-6,3x152 Peel Rivet 29 500 16,0000

7" 4-5/8" 6" 1241249 TPR-L-6,3x178 Peel Rivet 16 250 8,000

8" 5-5/8" 7" 1241250 TPR-L-3x203 Peel Rivet 18 250 8,000

9" 6-5/8" 8" 1241251 TPR-L-6,3x229 Peel Rivet 20 250 8,000

10" 7-5/8" 9" 1241252 TPR-L-3x254 Peel Rivet 22 250 8,000

TAURUS 2 Peel RivetPneumatic-hydraulic setting tool for the installation of TPR-L Peel RivetsMaterial No.: 1457802

InstallationPre-drill diameter for all substrates is 7mm (9/32"). The specially designed pneumatic pulling tool is required for all installations.

Note: Reduce maximum clamping length by 1/4" when fastening to wood fiber or fragile substrates.

Options

Head: Low Profile Mushroom Head Dia: .480" Shank Dia: .225" Installed Dia: 1.65"Pull-out (lbs avg.): 28 ga: 385 26 ga: 465 1/2" OSB: 330 3" Poured Gypsum: 430

Installation Tools isoweld®

Membrane Plates

Insulation Plates

SN2 Tong Rivet ToolHand operated setting tool for the installation of TPR-L Peel RivetsMaterial No.: 838870

Page 32: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

30SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Pre-Assembly Tool - Stealth #12 Dekfast with 3" round insulation plate

Roof Top ProductivityTools & Systems

• When installed with Stealth tools, productivity increases up to 30% and allows the contractor to install the roof assembly in a more ergonomically correct position versus standard installation methods.

• Screw and plate relationship is perpendicular every time, allowing for proper and quicker installations.

• Pre-assembled fasteners can be placed on the deck or loaded into the Stealth installation tools, giving the contractor the ability to use crew members in other areas of the roof project.

Application#12 Phillips w/ Round Galvalume PlateMechanical attachment of insulation per manufacturers’ requirementsMaterials: • Steel thickness from 22 ga (.028 in.)

through 18 ga (.045 in.): Min penetration: 3/4"

• Wood 2x (1-1/2" thick): Min penetration: 1"

Use with: • Stealth• Steel roof decks include all

FM approved 18-20-22 ga

#12 Hex w/ Round Galvalume PlateMechanical attachment of insulation per manufacturers’ requirementsMaterials: • Steel thickness from 22 ga (.028 in.)

through 18 ga (.045 in.): Min penetration: 3/4"

• Wood 2x (1-1/2" thick): Min penetration: 1"

Use with: • Stealth• Steel roof decks include all

FM approved 18-20-22 ga

StealthUse with: • #12 Dekfast with 3" Round insulation plate

Screw Gun Adaptor: Dewalt

Head Drive: #3 Phillips Head Height: Max .118" Head Dia: Max .448" Thread Major Dia: .222" Shank Dia: .167"Plate: 3" round Galvalume Material: AZ50 GalvalumeStrength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815Pull-out (lbs avg.): Steel 22 ga: 513 Steel 20 ga: 695 Steel 18 ga: 787 2x dimensional lumber (1" penetration): 462 3/4" FR Plywood: 575

Head Drive: 1/4" hex Head Height: Max .140" Head Major Dia.: Max .448" Thread Major Dia: .226" Shank Major Dia: .167"Plate: 3" Round Galvalume Material: AZ50 GalvalumeStrength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815Pull-out (lbs avg.): Steel 22 ga: 513 Steel 20 ga: 695 Steel 18 ga: 787 2x dimensional lumber (1" penetration): 462 3/4" FR Plywood: 575

Continued on following page

Page 33: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

31SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Pre-Assembly Tool - Stealth #12 Dekfast with 3" round insulation plate

Roof Top ProductivityTools & Systems

Selection Carton Carton Skid

Length Material No. North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty.

#12 Phillips Metal1-5/8” 785690 DF-#12x1-5/8-PH3-G3-E0999-B Up to 7/8” Up to 5/8” N/A 27 500 13,500

2-1/4” 785707 DF-#12x2-1/4-PH3-G3-E0999-B Up to 1-1/2” Up to 1-1/4” N/A 14 250 9,000

2-7/8” 785726 DF-#12x2-7/8-PH3-G3-E0999-B Up to 2-1/8” Up to 1-7/8” N/A 15 250 9,000

3-1/4” 784748 DF-#12x3-1/4-PH3-G3-E0999-B 1/2” to 2-1/2” 1/4” to 2-1/4” N/A 16 250 9,000

3-3/4” 785772 DF-#12x3-3/4-PH3-G3-E0999-B 1” to 3” 3/4” to 2-3/4” N/A 17 250 9,000

4-1/2” 785789 DF-#12x4-1/2-PH3-G3-E0999-B 1-3/4” to 3-3/4” 1-1/2” to 3-1/2” N/A 18 250 6,750

5” 785806 DF-#12x5-PH3-G3-E0999-B 2-1/4” to 4-1/4” 2” to 4” N/A 19 250 6,750

6” 785826 DF-#12x6-PH3-G3-E0999-B 3-1/4” to 5-1/4” 3” to 5” N/A 20 250 6,750

7” 785842 DF-#12x7-PH3-G3-E0999-B 4-1/4” to 6-1/4” 4” to 6” N/A 17 200 5,400

8” 785858 DF-#12x8-PH3-G3-E0999-B 5-1/4” to 7-1/4” 5” to 7” N/A 19 200 5,400

#12 Hex Metal1-5/8” 790082 DF-#12x1-5/8-HW1/4-G3-E0999-B Up to 7/8” Up to 5/8” N/A 26 500 13,500

2-1/4” 790088 DF-#12x2-1/4-HW1/4-G3-E0999-B Up to 1-1/2” Up to 1-1/4” N/A 14 250 9,000

2-7/8” 790091 DF-#12x2-7/8-HW1/4-G3-E0999-B Up to 2-1/8” Up to 1-7/8” N/A 15 250 9,000

3-1/4” 790096 DF-#12x3-1/4-HW1/4-G3-E0999-B 1/2” to 2-1/2” 1/4” to 2-1/4” N/A 16 250 9,000

3-3/4” 790100 DF-#12x3-3/4-HW1/4-G3-E0999-B 1” to 3” 3/4” to 2-3/4” N/A 17 250 9,000

4-1/2” 790103 DF-#12x4-1/2-HW1/4-G3-E0999-B 1-3/4” to 3-3/4” 1-1/2” to 3-1/2” N/A 18 250 6,750

5” 790106 DF-#12x5-HW1/4-E0999-B 2-1/4” to 4-1/4” 2” to 4” N/A 19 250 6,750

6” 790111 DF-#12x6HW1/4-G3-E0999-B 3-1/4” to 5-1/4” 3” to 5” N/A 20 250 6,750

7” 790116 DF-#12x7-HW1/4-G3-E0999-B 4-1/4” to 6-1/4” 4” to 6” N/A 17 200 5,400

8” 790119 DF-#12x8-HW1/4-G3-E0999-B 5-1/4” to 7-1/4” 5” to 7” N/A 19 200 5,400

SelectionStealth Tool Part No. Carton Qty.Stealth w/ 20" Extension 1201245 1

Approvals

* Does not include #12 Hex head assemblies

InstallationThe standard carton package includes one #3 Phillips bit.

NotesDimensions are nominal inches unless noted. Steel roof decks include all FM-approved 18-20-22 ga. FM-approved wood decks include 3/4" F.R. plywood and 2x dimensional lumber. Structural concrete to be predrilled with standard 3/16" carbide drill bit to minimum 1/2" deeper than fastener penetration. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners.

12-1017.07

State of Florida: FL20311 *

Page 34: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

32SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Reference

Approved FM Fastening Patterns

Factory Mutual Approved FM Fastening Patterns

Standard PatternsFasteners positioned 1 every 4 sq. ft.

Standard PatternsFasteners positioned 1 every 2 sq. ft.

Enhanced Fastener Patterns

1 per 2.6 sq. ft. 1 per 3 sq. ft. 1 per 3.2 sq. ft. 1 per 2.9 sq. ft.

Enhanced Fastener Patterns

1 per 2.4 sq. ft. 1 per 2.6 sq. ft. 1 per 2.6 sq. ft.

Page 35: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

33SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Reference

Fastener Selection

A Word About the Specification of FastenersProper fastener selection takes into account where

and how the fasteners are installed. Factors that

must be considered include: materials being

attached, environmental factors, installation

conditions, and safety issues. Because product

specifications, applications, and interpretations may

differ, specifiers and purchasers must make their

own product evaluation to be assured of suitability for

the intended use.

Disclosure StatementFastener data shown herein is subject to change or

correction for typographical error witout notice. All

test data and ultimate values shown in this catalog

are the result of laboratory testing. Specific job

conditions should be considered and appropriate

safety factors applied when specifying fasteners.

In actual applications, proper installation techniques

must be used to assure adequate performance of

the fastener. Assistance and recommendations

are available by contacting your SFS intec sale or

customer service professional.

Final selection of fasteners or accessories for use

is ultimately the decision of the purchaser. While

SFS intec, Inc. may assist by providing data and

information for comparison, it makes no suggestions

or warranties pertaining to the suitability of its

products for any particular applicaion.

Galvalume® is a registered trademark of BIEC

International, Inc.

Page 36: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

34SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Difference-making with Dekfast™

SFS intec has delivered fastening solutions for over fifty years to worldwide markets. The Dekfast™ brand is universally understood as the premier choice by specifiers and contractors for commercial low slope (flat roof) applications.

Fastening SolutionsDekfast™, an innovative and proven solution, is

designed, manufactured and tested to achieve

compliance with Factory Mutual (FM) 4470. Having

a wide variety of materials, thread styles, point

geometries, finishes and installation applications,

Dekfast is a preferred choice for insulation and

membrane attachment in wood, steel and concrete

decks.

Productivity SolutionsSFS intec offers stand-up roofing tools to

increase productivity and provide ergonomic

benefits to roofing contractors. Having used

SFS intec tools, contractors have reported

significant rooftop productivity gains for

insulation and membrane attachment … in

some cases productivity is "3x" faster. isofast®

and isoweld® are unmatched in the industry

and provide contractors with the edge required

to get on and off of the roof more quickly.

Job-Site SolutionsSFS intec provides rooftop consultation,

training and start-up support at no cost to the

market. Our rooftop training programs are

geared towards creating customer confidence

and competence with all of the Dekfast™ brand

offerings as well as our productivity tools. Job

site solutions include:

• pull tests

• project start-up

• rooftop crew training

Office-Based SolutionsSupporting the Dekfast™ brand is our highly

differentiated eSolutions service offering.

eSolutions is a web-based application which

streamlines customer order placement, tracking,

invoicing, etc. eSolutions empowers customers

to be in control of their material requirements.

Using eSolutions will lead to improved order

accuracy and reduced supply chain costs.

Page 37: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

35SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Page 38: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

36SFS intec | Dekfast™ Product Group | 1-800-234-4533 ©2017 SFS intec

Page 39: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R
Page 40: Low Slope Fastening Solutions Guide Featuring Products ... · Insulation Panel Fastener ... SFS intec "Intelligent Product Code" Dekfast Identification Convention Product Type BB-R

SFS intec Division Construction 1045 Spring Street PO Box 6326US-Wyomissing, PA 19610

800 234 4533T +1 610 376 5751F +1 610 376 [email protected]

SFS intec - Canada40 Innovation DriveDundas, ON L9H 7P3T +1 905 689 [email protected]

Manufacturing LocationsExeter Plant Lincoln Corporate Center, 41 Dennis Drive, Reading, PA 19606

Medina Plant 5201 Portside Drive, Medina, OH 44256

Wyomissing Plant 1045 Spring Street, PO Box 6326, Wyomissing, PA 19610

Canada Plant 40 Innovation Drive, Dundas, ON L9H 7P3

US Service Centers: Contact Us Toll Free: 1-800-234-4533 Toll-free Fax: 888-485-4225Northeast: 1045 Spring Street, PO Box 6326, Wyomissing, PA 19610 T: 610-376-5751 F: 610-376-8551

Northern Midwest: 500 West 3rd Avenue, Durant, IA 52747 T: 563-785-4990 F: 563-785-6997 Toll-free Fax: 888-211-4211

Southeast: 675 Progress Center Ave., Unit M, Lawrenceville, GA 30043 T: 770-995-5256 F: 770-995-3782

West Coast: 2426 Port Street, West Sacramento, CA 95691 T: 916-373-9912 F: 916-373-0176 Toll-free Fax: 888-488-8332

Canada Service Center: Contact Us Toll-Free : 1-866-847-5400 Toll-free Fax: 855-858-530040 Innovation Drive, Dundas, ON L9H 7P3 T: 905-689-5401 F: 905-689-9474

© 2017 SFS intec / Printed in USA Technical Changes Reserved January 2017

Technical advice and sales service

Our Technologies Provide easier, faster & more secure working methods

Reduce supply chain costs

Minimize errors

Improve information availability

eSolutions - Supply Chain innovations are just a click away

Job Pack

ePortal

ePost

eShop

eScan

VMI

EDI

eFormat

ePullout

Visit our website, or contact our eSolutions specialist to learn more. www.sfsintecusa.com 1-800-234-4533