21
Page 1 COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION Lightweight 2-kW Generator with Integrated Starter Alternator (ISA) April 25, 2007 2007 Joint Service Power Expo San Diego, CA Gregory Cole [email protected] Mainstream Engineering Corporation 200 Yellow Place Rockledge, FL 32955 www.mainstream-engr.com

Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

  • Upload
    vukhanh

  • View
    229

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 1COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Lightweight 2-kW Generator with Integrated Starter Alternator (ISA)

April 25, 20072007 Joint Service Power Expo

San Diego, CA

Gregory [email protected] Engineering Corporation200 Yellow PlaceRockledge, FL 32955www.mainstream-engr.com

Page 2: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 2COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Origin of Mainstream’s 2-kW Generator

• Engine Development (1991- )– Customer: U.S. Army RD&E Center (Natick)– Application: Small, diesel-powered, personal cooling system

• Alternator Development (1994 - )– Customer: U.S. Army Aberdeen / OST– Application: Miniature, multi-fueled generator

• Results– Diesel-cycle is better than Rankine, Stirling, Brayton, and

converted spark ignition (gasoline)– Mainstream designs and produces integrated, custom machines

Page 3: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 3COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Advantages of Mainstream’s 2-kW Generators

Alternator integrated into engine flywheel

• smaller and lighter• more reliable

Fan integrated into flywheel

• cools power electronics, engine head, oil sump

• runs cooler - increases life and reliability

Custom engine and generator designs

• sized specifically for application

• not just packaging of commercial components

Page 4: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 4COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Evolution of Mainstream’s 2-kW Generator

2000-05: SBIR Program to develop generator for Marine Corps’ Team Portable Collection System (TPCS)

– Marines wanted 1-kW (min.) 28- VDC generator weighing less than 50 lbs

– Manual recoil starter was desired because external starting power not available for electronic start

– Voltage regulation was not required because external power conditioning system in use

– Result: 2-kW 28-VDC generator

48 lbs unmounted

80 lbs fullyinstrumentedand framed

Page 5: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 5COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Future of Mainstream’s 2-kW Generator• 2006-07: IR&D

– Developed patent-pending ISA – Developing integral AC inverter

with soft-start motor technology• 2006-2007: Hybrid-Electric

Refrigerated Container– Mainstream’s generator powers a

24-VDC bus and recharges batteries

– Demo at JOCOTAS next week• 2007: Cooperative Research and

Development Agreement (CRADA) with Army RDECOM

– Army RDECOM to perform lab tests this summer at Ft. Belvoir

Page 6: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 6COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Integrated Starter/Alternator

• Electric start• Voltage regulation• Auto-start/stop• Battery charging circuit• Allows integration into 24-VDC hybrid electric

systems

Page 7: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 7COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Army RDECOM Laboratory Tests (per MIL-STD-705C)

• Physical Characterization• 503.1c Start and Stop Test• 601.4b Voltage Waveform Test (Harmonic Analysis)• 601.5 Voltage Waveform Test (Deviation Factor)• 602.1b Voltage Modulation Test• 608.1b Frequency and Voltage Regulation, Stability, and Transient

Response Test (Short Term)• 610.1b Voltage and Frequency Droop Test• 619.2c Voltage Dip and Rise for Rated Load Test• 640.1d Maximum Power Test (at 125°F)• 650.1b Ripple Voltage Test• 660.1d Inclined Operation test• 661.2c Sound Level Test• 670.1b Fuel Consumption Test• 690.1d Endurance Test• 701.1d Starting and Operating Test (Extreme Cold Battery Start)• 710.1d High Temperature Test

Page 8: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 8COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Physical Characterization

28-VDC Generator Comparison

Model MEP-501A MainstreamMFEG- 020028

Dry Weight 124 lbs1 93 lbs

Wet Weight 138 lbs2 102 lbs

Size 30” (L)1

16” (W)1

22” (H)1

18” (L)18” (W)20” (H)

120-VAC Generator Comparison

Model MEP-531A MainstreamMFEG- 020120

Dry Weight 143 lbs1 118 lbs3

Wet Weight 158 lbs2 127 lbs3

Size 30” (L)1

16” (W)1

22” (H)1

18” (L)18” (W)20” (H)

1 Army TM 9-6115-673-13&P2 http://www.pm-mep.army.mil/technicaldata/2kw.htm3 Projected based on design

Page 9: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 9COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

503.1c Start and Stop Test

28-VDC Generator

Performance Specification For Military Mobile Power Sources (0.5kW TO 15kW)

MainstreamMFEG-020028

Start TimeThreshold – 5 minObjective – 3 min 3.3 sec

Stop Time 2 min 3.8 sec

Page 10: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 10COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

28-VDC Generator

MIL-STD- 1332B

MainstreamUnregulatedGenerator

Voltage - Regulation

4% 20.9%

Voltage – Steady-State Stability

2% 6.6%0 300 600 900 1200

[Seconds]

0

9

18

27

36

45

-9

C1_

DC

_Vol

t age

[V]

Prior test results from Army RDECOM with Mainstream’s unregulated generator

Page 11: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 11COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

28-VDC Generator

MIL- STD- 1332B

MainstreamMFEG-020028

Voltage - Regulation

4% 3.9% @ 100% load*

3.9% @ 75% load3.4% @ 50% load2.8% @ 25% load

Voltage – Steady- State Stability

2% 1.1 @ 100% load1.1 @ 75% load1.1 @ 50% load1.1 @ 25% load1.0 @ 0% load

Current test results with Mainstream’s regulated generator with ISA

-9

0

9

18

27

36

45

0 200 400 600 800 1000 1200

Page 12: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 12COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

610.1b Voltage and Frequency Droop Test

28-VDC Generator

MIL-STD- 1332B

MainstreamMFEG- 020028

Voltage - Droop

not specified 1.4%24

26

28

30

32

34

0 50 100 50 0

Load (%)

Page 13: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 13COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

619.2c Voltage Dip and Rise for Rated Load Test

28-VDC Generator

MIL-STD- 1332B

MainstreamUnregulatedGenerator

Voltage –Dip

30% 24.8%

Recovery Time

2 sec 0 sec

Voltage - Rise

40% 22%

Recovery Time

2 sec 0 sec

Prior test results from Army RDECOM with Mainstream’s unregulated generator

0 2000 4000 6000 8000

28

30

32

34

36

38

Dat

aSet

[Volta

ge]

0 2000 4000 6000 8000

28

30

32

34

36

38

40

Dat

aSet

2 [ V

olta

ge]

Page 14: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 14COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

619.2c Voltage Dip and Rise for Rated Load Test

28-VDC Generator

MIL-STD- 1332B

MainstreamMFEG- 020028

Voltage –Dip

30% 6.2%

Recovery Time

2 sec 0.1 sec

Voltage - Rise

40% 5.5%

Recovery Time

2 sec 0.6 sec

Current test results with Mainstream’s regulated generator with ISA

24

26

28

30

32

34

0 5 10 15 20

24

26

28

30

32

34

0 5 10 15 20

Page 15: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 15COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

650.1a Ripple Voltage Test

28-VDC Generator

MIL-STD- 1332B

MainstreamUnregulatedGenerator

Voltage - Ripple

5.5% 9.4%*

0 2000 4000

28.8

29.6

30.4

31.2

32

32.8

Dat

aSet

3

Prior test results from Army RDECOM with Mainstream’s unregulated generator

* Reduced to 2.9% with 0.16 lb capacitor

Page 16: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 16COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

650.1a Ripple Voltage Test

28-VDC GeneratorMIL-STD- 1332B

MainstreamMFEG- 020028

Ripple0% Load

5.5% 0.55%

Ripple25% Load

5.5% 0.55%

Ripple50% Load

5.5% 0.60%

Ripple75% Load

5.5% 0.59%

Ripple100% Load

5.5% 0.63%

Current test results with Mainstream’s regulated generator with ISA

26

27

28

29

30

0 10 20 30 40 50 60

Page 17: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 17COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

670.1b Fuel Consumption Test

28-VDC GeneratorLoad(W)

Load(%)

Fuel Consumption(lbs/hr)

Fuel Consumption(gal/hr)

0 0% 0.80 0.120

425 21% 1.04 0.156

975 49% 1.07 0.160

1460 73% 1.23 0.185

1990 100% 1.49 0.223

For Comparison: “The Power Generation Branch has numbers showing some MTGs to use only 0.26 gal/hr of JP-8 at full load. The 0.33 is a fleet maximum.” – Army CECOM

Prior test results from Army RDECOM with Mainstream’s unregulated generator

Page 18: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 18COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

No Change Expected for the Following Tests

• 660.1d Inclined Operation Test– 20°

• 661.2c Sound Level Test– 79 dBA at 7 m

• 690.1d Endurance Test– RDECOM testing for 150 hrs

• 710.1d High Temperature Test– RDECOM will test to 135°F (previously 125°F)

Page 19: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 19COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Changes Expected for the Following Tests

• 640.1d Maximum Power Test– More efficient power converter will increase max

power

• 701.1d Starting and Operating Test (Extreme Cold Battery Start)– ISA with electric start will allow for extreme cold

weather starting

Page 20: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 20COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Summary• Mainstream’s 2-kW Generators

– 28 VDC– 120 VAC, 60 Hz

• 39% smaller than MTG• 17-25% lighter than MTG• 33% more efficient than MTG• 3-6x more reliable than MTG• New Features:

– ISA– Battery charging circuit– Auto-start/stop– Hybrid-electric ready– AC inverter with soft-start

Page 21: Lightweight 2-kW Generator with Integrated Starter ... · 608.1b Frequency and Voltage Regulation, Stability, and Transient Response Test

Page 21COPYRIGHT © MAINSTREAM ENGINEERING CORPORATION

Contact Information• Company Address

Mainstream Engineering Corporation200 Yellow PlaceRockledge, FL 32955(321) 631-3550www.mainstream-engr.com

• Points of Contact– Technical: Greg Cole, [email protected]– Contracts: Michael Rizzo, [email protected]

• Booth #312