Lenovo Storage V SeriesV3700 V2
2016 Lenovo. All rights reserved.
Dr. Martin Springer, Data Center Group Technical Sales
August 2016
22016 Lenovo. All rights reserved.
Lenovo Storage V Series, Announcement 6. Juni 2016
Lenovo Storage V Series – 12Gb SAN
Form Factor• 2U 12 LFF• 2U 24 SFF
Segment• Entry SAN (PB 3-4)• Entry / Midrange SAN (PB-5)
Target Market
• V3700 V2: deployed for specific application or solution, specific infrastructure rollout
• V5030: High performance controller requirement, shared datacenter storage
Value Proposition• Tier 1 offering to compliment Lenovo Storage• Leverages existing storage environments
Key Features• Latest CPUs and 12G I/O (higher performance)• Designed for flexibility and scalability• Advanced SW features
32016 Lenovo. All rights reserved.
Lenovo Storage V Series Highlights• New „Lenovo Storage V Series“ branding
• More powerful hardware platform with new processors and additional cache– 2x performance of previous V3700 / V5000 systems
– Up to 4x cache: 16 GB, 32GB or 64GB cache per system
– 2x infrastructure speed: 12Gbps SAS and 16Gbps FC
• Improved scalability: Up to 20 expansion enclosures (V5030)– Up to 504 SFF drives or 252 LFF drives per system
– Up to 1008 SFF drives or 504 LFF drives per clustered system
• Two new models:– Lenovo Storage V3700 V2 (MT 6535) Lenovo Storage V5030 (MT 6536
• Planned availability V3700 generation 1: Controller: 5/2017
Expansions: Enclosures: 1/2018
V5030
V3700 V2
42016 Lenovo. All rights reserved.
Lenovo Storage V Series – ÜberblickLENOVO V3700 V2(6535C1D-6535C2D)
LENOVO V3700 V2(6535C3D-6535C4D)
LENOVO V5030
Target Market Entry Entry Entry / Mid Range
Target Workloads
Entry Shared storageRemote & Branch Office
Primary StorageRemote & Branch OfficeVirtualization, Backup
Enterprise StorageI/O intensiveVirtualization, Database
Performance 50k IOPs (RD) 100k IOPs (RD) 175k IOPs (RD)
Value Proposition
Established Enterprise SW Stack, Advanced SW Features, Flexible Scalable Design
HW Features
Lenovo Branded 2U 12 LFF & 2U 24 SFF, 12Gb host and backend IOInterchangeable drive trays, chassis and power supply
SW Features
Automated TieringRemote Mirror/IP ReplicationDRAIDInternal Virtualization
Automated TieringRemote Mirror/IP Replication DRAID Internal Virtualization
PLUSCompressionExternal Virtualization EncryptionClustering
52016 Lenovo. All rights reserved.
Lenovo Storage V Series – FunktionenINTERNAL VIRTUALISATION
• Rapid, flexible provisioning and simple configuration changes
• Enables non disruptive movement of data among tiers of storage
DATA PROTECTION WITH FLASHCOPY
• Create copies for backup, parallel processing, testing & development
• Base feature provides up to 64 FlashCopy targets
OPTIONAL PREMIUM FEATURES
• Easy Tier : automatically and dynamically moves frequently accessed data to flash
• FlashCopy Upgrade : increase support to up to 2,048 FlashCopy targets per system
• Remote Mirroring : data replication using synchronous or asynchronous data transfers
V37
00 V
2
EXTERNAL VIRTUALISATION
• Manage all storage from a single pane of glass improving productivity
• Move data transparently between external storage and the V5/V7
• All advanced functionality can extend to virtualized storage
HYPER SWAP
• Dual-site, active-active access to a volume for HA and DR
• Maintain access to data on the system when site-wide failures or outages occur
DATA PROTECTION WITH ENCRYPTION
• Enabled on entire V5030 system
• External virtualized arrays, no need to replace present arrays
• Works with traditional drives, no SEDs required
REAL-TIME COMPRESSIONTM
• Up to 5x as much data in the same physical disk space
• Designed to be used with active primary data (production sites, email systems)
• Compress data on non-V5030 arrays via external virtualization
V50
30
V5030
VirtualizedStorage
External Virtualization
62016 Lenovo. All rights reserved.
Lenovo Storage V Series – PositionierungEntry Entry Entry / Midrange
Cos
t
Performance/ Scalability
V3700 V2
2U 12 LFF or 24 SFF2-core Broadwell-DE Celeron
12Gb host and BE Expansion
(6535C1D-6535C2D)
• Entry Level/Primary/ROBO/Retail
• Web & File serving, backup, small
database
• Value Entry SAN storage
• Datacenter/Primary Storage
• Data Analytics, Private Cloud,
HealthCare,
Telecommunications
• Storage that has Scalability and
Availability
• Mid Level / Enterprise
• Database, Private Cloud, Data
Analytics
• Powerful, Storage
• Encryption, Compression, Ext
Virtualization
V3700 V2 (XP)
2U 12 LFF or 24 SFF2-core Broadwell-DE Xeon
12Gb host and BE Expansion
(6535C3D-6535C4D)
V5030
2U 12 LFF or 24 SFF6-core Broadwell-DE Xeon
12Gb host and BE Expansion
8
- VS - Feature V Series 6Gb V Series 12Gb
V3700vs
V3700 V2(6535C1D, 6535C2D)
CPU 2-core Sandy Bridge Celeron 2-core Broadwell-DE Celeron
Host ports2x 1GbE, 3x 6G SAS,Interface card slot
2x 1GbEInterface card slot
Expansion ports 1x 6Gb SAS 1x 12Gb SAS
Memory (min/max) 4GB / 8GB 8GB / 8GB
V3700vs
V3700 V2(6535C3D, 6535C4D)
CPU 2-core Sandy Bridge Celeron 2-core Broadwell-DE Xeon
Host ports2x 1GbE, 3x 6G SAS,Interface card slot
2x 1GbE, 2x 12G SAS,Interface card slot
Expansion ports 1x 6Gb SAS 1x 12Gb SAS
Memory (min/max) 4GB / 8GB 8GB / 16GB
V5000vs
V5030
CPU 4-core Ivy Bridge Xeon 6-core Broadwell-DE Xeon
Host ports2x 1GbE, 3x 6G SAS,Interface card slot
1x 1GbE, 2x 10GbE, 2x 12G SAS,Interface card slot
Expansion ports 2x 6Gb SAS 2x 12Gb SAS
Memory (min/max) 8GB / 8GB 16GB / 32GB
2016 Lenovo. All rights reserved.
Storwize 6Gb vs V Series 12Gb
92016 Lenovo. All rights reserved.
Lenovo Storage V Series – Hardware-VergleichV3700 V2 V5030
CPU2-core, 1.2GHz,
1600MHz memory bus
2-core, 2.2GHz, Hyper-threading,
1866MHz memory bus
6-core, 1.9GHz,Hyper-threading,
2133MHz memory bus
SAS Hardware Encryption None Yes
Host iSCSI Support 2 x 1GbE RJ45 2 x 10GbE RJ45
Standard Host SAS None 2 x 12Gb None
Expansion Slots 1 PCIe 1 PCIe
Disk Expansion SAS 1 x 12Gb 2 x 12Gb
Cache (per system) 16GB 16GB or 32GB 32GB or 64GB
Capacity (per system)Up to 240 drives
(Up to 9 expansions)Up to 504 drives
(Up to 20 expansions)
Clustered capacity -- Up to 1,008 drives
Standard memory 1 x 8GB DIMM 1x 16GB DIMM
Optional memory None 1 x 8GB DIMM 1 x 16GB DIMM
Lenovo MTMs 6535C1D, C2D, EC1, EC2 6535C3D, C4D, EC3, EC4 6536C12, C32, C22, C42
ECx: TopSeller
102016 Lenovo. All rights reserved.
Neue V Series Enclosures• New control enclosures available in 2.5 and 3.5-inch drive models
– 2U, 19-inch rack mount enclosure
• New expansion enclosures available in 2.5 and 3.5-inch drive models
– Attaches to new control enclosure using 12Gbps SAS
– Mix drives of the same form factor within enclosure
2.5-inch Flash Drives
400GB, 800GB, 1.6 TB and 3.2 TB Flash 12Gbps
2.5-inch High Performance Drives
300GB, 600GB SAS, 15K RPM 12Gbps
900GB, 1.2TB, 1.8TB SAS, 10K RPM 12Gbps
2TB NL-SAS, 7.2K RPM 12Gbps
3.5-inch High Capacity Drives
4TB, 6TB and 8TB NL-SAS, 7.2K RPM 12Gbps
112016 Lenovo. All rights reserved.
Lenovo Storage V3700 V2
• Two node canister, each with a two-core processor• 16 GB cache with optional 32 GB1 cache• Flexible interface options
• Two 12 Gb SAS ports for expansion enclosure attachment• V3700 V2 systems scale up to 240 SFF drives with 9 expansion enclosures or up to 960TB with
120 LFF drives
Ports per system
Standard Optional
1 GbE12 Gb SAS
16 Gb FC
10 Gb FCoE
12 Gb SAS
1 Gb iSCSI
4 4* 8 8 8 8
1 available on the following models: 6535C3D, C4D, EC3, EC4
Models 6535C3D, C4D, EC3, EC4
Models 6535C1D, C2D, EC1, EC2
122016 Lenovo. All rights reserved.
Lenovo V3700 V2 Controllers – Rückseite
USB port
Optional HICTechnician port(may be used for 1GbE I/O after setup)
Onboard 12Gb SAS (Disk expansion)
Management and I/O port (1GbE)
Controller LEDsBattery LEDs
USB port
Optional HICTechnician port(may be used for 1GbE I/O after setup)
Onboard 12Gb SAS (Disk expansion)
Controller LEDsBattery LEDs
Onboard 12Gb SAS (Host only)
Management and I/O port (1GbE)
V3700 V2
V3700 V2
6535C1D - 6535C2D
6535C3D - 6535C4D
132016 Lenovo. All rights reserved.
Enclosures : Lenovo V3700 V2
V3700 V2 LFF
V3700 V2 SFF
Lenovo logoLenovo model name
142016 Lenovo. All rights reserved.
Lenovo V3700 V2 Expansion – Rückseite
12Gb technology
V3700 V2 expansion enclosures support a single SAS chain of up to 9 expansion enclosures• The V3700 V2 Control Enclosures are on their own SAS chain
Control and expansion enclosures are available in both 12-slot LFF (3.5”) and 24-slot SFF (2.5”) variants• SFF drives available in LFF drive carriers for use in LFF enclosures
162016 Lenovo. All rights reserved.
Spectrum Virtualize SoftwareEasy Tier Provide automatic migration of frequently accessed data elements to high-performing flash storage
Encryption for virtualized storage* Helps improve security for data without requiring upgrades to existing storage systems
Real-time Compression*
Helps improve efficiency by storing up to five times as much active primary data in the same physical disk space; by significantly reducing storage requirements, you can keep up to five times more information online, use the improved efficiency to reduce storage costs, or achieve a combination of greater capacity and reduced costEnable up to five times as much data to be stored on your existing storage, while also reducing your future storage needs
External virtualization*Virtualize your existing storage to make it part of a Lenovo V5030 system, where it inherits the advantages of V Series capabilities
Thin provisioningSupport business applications that need to grow dynamically, while consuming only the space actually used
Metro Mirror and Global MirrorAllow synchronous or asynchronous data replication between V Series family offerings for maximum flexibility and backup efficiency; support Fibre Channel, Fibre Channel over Ethernet (FCoE), and IP (Ethernet) networking
FlashCopyCreate a near-instant copy of active data that can be used for backup or for parallel processing activities; support recovery of corrupted data
Dynamic migration Provide nondisruptive migration to speed implementation
HyperSwap Allow high-availability configurations for resilient virtualized environments
Storage Mobile Dashboard Provide basic monitoring capabilities to securely check the health and performance status of your system
*available on V5030 systems only
172016 Lenovo. All rights reserved.
Spectrum Virtualize Software• 7.6.1
– Software release designed to support the new 12Gb hardware models
• All Lenovo Storage V3700 V2 and V5030 models will initially ship with 7.6.1 code
– No new functions are being introduced
• Roll up of V7.6.0.x fixes and support for the new 12Gb systems
– Note that the minimum memory to support V7.6.1 is 8GB per node canister
• V3700 Gen 1 systems with 4GB of memory per canister cannot be upgraded to V7.6.x.x
• 7.7.0– No new PNs or Feature Codes being released
• V3500/V3700 Gen 1 requires 8GB cache feature prior to installing
Lenovo to post new firmware within 3 days of receipt from IBM
182016 Lenovo. All rights reserved.
V Series – Software-FunktionenV3700 V2
(6535C1D, 6535C2D)V3700 V2
(6535C3D, 6535C4D)V5030
Compression Yes (64GB RAM)
HW Encryption-Int Yes
Software Encryption-Ext Yes
DRAID Yes Yes Yes
External Virtualization Migration only Migration only Yes
vVols Yes Yes Yes
HyperSwap Yes
FlashCopy Yes Yes Yes
Remote Copy Yes Yes Yes
Easy Tier Yes Yes Yes
Clustering Yes (2 IO Groups)
Clusteringw/V5000 Gen1
Yes
Technician Port Yes (Disabled after setup) Yes (Disabled after setup) Yes (Permanent)
192016 Lenovo. All rights reserved.
Optionale Funktionen: Freischaltung über LizenzenPriced, optional features on Lenovo Storage V3700 V2 Control Enclosures
•FlashCopy upgrade•Remote mirroring•Easy Tier
Technically activated with a “License Key”
• A “Licensed Function Authorization” document is shipped when above features are ordered• Client uses “Authorization Code” from the document to obtain License Key for their machine• Client installs License Key on machine to technically activate the function
License terms
• Licensed to a Lenovo Storage V3700 V2 control enclosure• Single license covers entire Lenovo Storage V3700 V2 system (control enclosure and all
attached expansion enclosures)• Once activated, functions remain licensed to the machine and cannot be transferred to
another machine• If machine is sold or transferred, all activated functions remain active and license ownership
transfers with the machine
Note: Hardware and licensed functions must be purchased from Lenovo. Intermixing between vendors is not supported.
ACTIVATION
A physical piece of paperimprinted with a unique, one-time-use Authorization Code
Authorization Code is notassociated with a machineuntil “activation” is performed
License Key must bephysically installed onmachine to activate thefunction
202016 Lenovo. All rights reserved.
V3700 V2 Trial - LizenzenTO HELP EVALUATE THE BENEFITS, SELECT FUNCTIONS* CAN BE ENABLED AT NO CHARGE FOR 90 DAYS
• Easy Tier• Remote mirroring• Each function can be enabled only once for the 90 day trial
TRIALS ARE CLIENT-INITIATED FROM GUI AND DON’T REQUIRE LENOVO INTERVENTION
• During the trial, functions behave in same manner as if purchased and enabled with a License Key• Informational and warning event notifications are issued to notify client of days remaining until expiration
UPON EXPIRATION OF TRIAL, A FUNCTION IS AUTOMATICALLY DISABLED
• unless a License Key for that function has been installed onto the machine
TRIALS ARE ENABLED ON A PER-FUNCTION BASIS
• All functions don’t need to be evaluated simultaneously
[*] : The FlashCopy upgrade function (support for up to 2,040 targets) cannot be enabled for the 90 day trial. FlashCopy support for up to 64 targets is a standard function on all machines and therefore it can be used to evaluate the benefits of FlashCopy.
21
FlashCopy
• FlashCopy (snapshot) function is optional for up to 4096 targets
• Enables taking more or more frequent copies
� Support more VMs from a single master copy
� Enables more work to proceed in parallel
• More copies can reduce impact of having to use a backup copy
� For example, taking a copy every hour instead of every day
� Reduces potential impact by up to 95%
2016 Lenovo. All rights reserved.
22
Improve performance up to 3x
… using as little as 5%flash storage
� Constantly analyzes I/O
� Migrates data to optimize performance
� Set it and forget it … unlike competitive tiering offerings
Easy TierImprove Storage Performance
2016 Lenovo. All rights reserved.
23
� Effortlessly, intelligently distribute workload across storage in a pool
� Maximizes system throughput
� Takes into account performance capability of different arrays
� Minimizes system tuning effort
� Eliminates manual movement when adding new storage to a pool
� Turned on by default for all storage pools
� No additional charge
Storage Pool BalancingAchieve Faster Response Times
2016 Lenovo. All rights reserved.
24
Distributed RAID
• Improved RAID implementation� Faster drive rebuild improves availability
� Enables use of lower cost larger drives with confidence
� All drives are active, which improves performance especially with flash drives
• Spare capacity, not spare drives
• Rotating spare capacity position distributes rebuild load across all drives
• More drives participate in rebuild� Bottleneck of one drive is removed
• More drives means faster rebuild� 5-10x faster than traditional RAID
� Especially important when using large drives
• No “idle” spare drives� All drives contribute to performance
� Especially important when using flash drives
Improve Data Protection
2016 Lenovo. All rights reserved.
252016 Lenovo. All rights reserved.
V3700 V2 – Data Migration
1. Fibre channel SAN
• Existing data can be migrated over FC from a large number of supported IBM and non-IBM storage systems using Image Mode Migration capability
• Can use this process to migrate from a Gen1 V3700/5000/7000 to V3700 V2 if desired (must change “layer” to ‘replication’ on V2 systems)
2 OPTIONS FOR DATA MIGRATION
2. Direct attach SAS storage devices
• Only available for migrating data from Gen1 V3500/3700/5000 systems to the V3700 V2 that has SAS host ports standard
REPLICATENew V3700 V2 System
IMAGE MODE
Any Storwize Model
Any Storwize Model
26
� Speed replication cycles for better remote data currency and faster recovery
� Enables use of Ethernet connections for remote mirroring
� Transparent to servers and applications
� Includes Bridgeworks SANrockIT network optimization technology
• No separate appliances required
• Uses artificial intelligence to improve network bandwidth utilization up to 3x
� Deploy less costly network infrastructure
IP Replication
SourceVolume
DestinationVolume
TCP/IP Network
Improved Disaster Recovery
2016 Lenovo. All rights reserved.
27
Lenovo V Series Offers a Wide Range of ISV Integration
• Enablement, integration and optimization for enhanced customer value
� Reduce complexity, improve utilization and cut costs
� Deliver continuous and reliable access to information
• Targeted solution areas include:
� Database and performance optimization
� Backup / restore
� High availability, disaster recovery
� Server virtualization
� Operations management
2016 Lenovo. All rights reserved.
28
StorageVMware / IBM / Lenovo Storage Integration Capabilities
� vCenter Management of IBM / Lenovo Storage
• Provisioning, mapping and monitoring IBM storage in vSphere
� vStorage APIs for Array Integration (VAAI)
• Host server offload capability
� vStorage APIs for Storage Awareness (VASA)
• IBM Storage Overview
• Profile driven storage direction
� Site Recovery Manager (SRM) Integration
• Replication simplification
• vRealize Suite (vCloud Suite)
• Includes VMware vCenter Orchestrator (vCO), VMware vCenterOperations Manager (vCOPS) and VMware vCloud Automation Center (vCAC)
� IBM Spectrum Control Base
• Central Storage Control Plane for Cloud
� vSphere Virtual Volumes (VVOLs)
• Technology Demo (XIV) available at https://www.youtube.com/watch?v=HZtf5CaJx_Y&feature=youtu.be
� vStorage APIs for Data Protection (VADP)
• Spectrum Protect Snapshot and Spectrum Protect for Virtual Environments
2016 Lenovo. All rights reserved.
29
Lenovo Storage V Series - VMware Integration� VMware VVOL
� Uses Lenovo Spectrum Control Base Software to integrate into existing VMware environments
� Linux VM required to run the Lenovo Spectrum Control Base
� VALUE: Simplifying Storage Operations for VMware admins
� Lenovo Spectrum Control Base Software
� Linux Application with Web UI
� Allows remote control of Lenovo StorageV Series from within vCenter UI
� Single pane of glass & can simplifyLenovo Storage V Series tasks.
� Storage Capabilities defined for Policy-BasedManagement
� Storage Admin can allocate storage with pools
� VALUE: Simplifying Storage Operationsfor VMware admins
2016 Lenovo. All rights reserved.
30
IBM Storage Management Pack for Microsoft SystemCenter Operations Manager (SCOM)
Monitoring IBM Spectrum Virtualize and IBM Storwize 7.5 withMicrosoft System Center Operations Manager (SCOM) https://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP102607
SCOM can be extended by importing management packs (MPs) which define how SCOM monitors systems.The Free Integration into Microsofts System Center Operations Manager monitors
31
Microsoft Off loaded Data Transfer (ODX)� ODX is the Microsoft equivalent of the VMWare VAAI interfaces
� Allows Windows Server 2012 hosts to move or copy data within a Storwize array without moving the data through the SAN.
� Can significantly reduce client-server network traffic and host CPU usage during large data transfers because all data movement is within the array back end.
� Windows 8 & Windows 2012 supported
� Main user will be Hyper V - when deploying virtual machines" but even “drag-and-drop” copying of large files will invoke ODX
� ODX is turned ON by default and can be turned off via the CLI using 'chsystem' command if required
� Neither VAAI or ODX reduces the amount of work performed by the storage controller - they just save work in the host server and reduce traffic on the SAN.
� Consequently 'bench marking' the performance benefits of these features is difficult because it is not just sufficient to generate a heavy I/O workload you need to generate a heavy CPU workload on the host system as well.
https://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP102590
322016 Lenovo. All rights reserved.
V Series – 12Gb Model ComparisonLenovo Storage V5030 Lenovo Storage V3700 V2
Connectivity (Standard)10Gb iSCSI1Gb iSCSI
12Gb SAS1Gb iSCSI
1Gb iSCSI
Connectivity (Optional)
16Gb FC12Gb SAS
10Gb iSCSI / FCoE1Gb iSCSI
16Gb FC12Gb SAS
10Gb iSCSI / FCoE1Gb iSCSI
Cache (per system) 32GB or 64GB 16GB or 32GB 16GB
Capacity
(per system)
Up to 504 drives(Up to 20 expansions)
Up to 240 drives(Up to 9 expansions)
Clustered Capacity Up to 1,008 drives -
Internal Virtualization Yes Yes
Thin Provisioning Yes Yes
Data Migration Yes Yes
FlashCopy (optional) Yes Yes
Remote Mirroring (optional) Yes Yes
Easy Tier (optional) Yes Yes
Encryption (optional) Yes No
System Clustering Yes (2-way) No
External Virtualization (optional) Yes No
Real-time Compression (optional) Yes No
All Flash Yes No
Power AC or DC** AC or DC**
Lenovo Control Enclosure MTMs 6536C12, C32, C22, C42 6535C3D, C4D, EC3, EC4 6535C1D, C2D, EC1, EC2
** Lenovo DC model available via special bid only
33
Storwize V5030 Lenovo V5030 Storwize V5020 Lenovo V3700 V2 XP Storwize V5010 Lenovo V3700 V2
Connectivity (Standard)10Gb iSCSI1Gb iSCSI*
- Same. -
12Gb SAS1Gb iSCSI
12Gb SAS1Gb iSCSI
1Gb iSCSI1Gb iSCSI*
Connectivity (Optional)
16Gb FC12Gb SAS
10Gb iSCSI / FCoE1Gb iSCSI
16Gb FC12Gb SAS
10Gb iSCSI / FCoE1Gb iSCSI
16Gb FC12Gb SAS
10Gb iSCSI / FCoE1Gb iSCSI
16Gb FC12Gb SAS
10Gb iSCSI / FCoE1Gb iSCSI
16Gb FC12Gb SAS
10Gb iSCSI / FCoE1Gb iSCSI
Cache (per system) 32GB or 64GB 16GB or 32GB 16GB or 32GB 16GB 16GB
Capacity (per system)
Up to 504 drives(Up to 20 expansions)
Up to 264 drives(Up to 10 expansions)
Up to 240 drives(Up to 9 expansions)
Up to 264 drives(Up to 10 expansions)
Up to 240 drives(Up to 9 expansions)
Clustered Capacity Up to 1,008 drives -- - -- -
Internal Virtualization Yes Yes Yes Yes Yes
Thin Provisioning Yes Yes Yes Yes Yes
Data Migration Yes Yes Yes Yes Yes
FlashCopy (Opt) Yes Yes Yes Yes Yes
Remote Mirroring (Opt) Yes Yes Yes Yes Yes
Easy Tier (Opt) Yes Yes Yes Yes Yes
Encryption (Opt) Yes Yes No -- No
System Clustering Yes (2-way) -- - -- -
External Virtualization (Opt)
Yes -- - -- -
Real-time Compression (Opt)
Yes -- - -- -
All Flash Yes -- - -- -
Model upgrade - Yes No Yes No
Power AC or DC** AC or DC** AC or DC** AC or DC** AC or DC**
NEBS / ETSI Statement of Direction Statement of Direction Statement of Direction Statement of Direction Statement of Direction
*1Gb iSCSI for technician use only** DC model available via special bid only
Lenovo Storage V vs IBM Storwize
2016 Lenovo. All rights reserved.
342016 Lenovo. All rights reserved.
Lenovo Storage V3700 V2 vs. EMC VNXe & VNX5200Competitive comparison
V3700 V2Models C1D, C2D, EC1, EC2
EMC VNXe1600 EMC VNXe3200V3700 V2
Models C3D, C4D, EC3, EC4EMC VNX5200
Form factor / Height 2U 2U 2U 2UController 3U, Drive 2U (25 HDDs) / 3U (15 HDDs)
Controllers 2 2 2 2 2
Max number of drives 240 (SFF) / 120 (LFF) 200 150 240 (SFF) / 120 (LFF) 125
Drive types 2.5"/3.5" SAS, NL SAS, Flash 2.5"/3.5" SAS, NL SAS, Flash 2.5"/3.5" SAS, NL SAS, Flash 2.5"/3.5" SAS, NL SAS, Flash 2.5"/3.5" SAS, NL SAS, Flash
Max capacity 480 TB / 960 TB (8 TB) 400 TB 500 TB 480 TB / 960 TB (8 TB) 500 TB
Max cache memory 16 GB 16 GB 24/48 GB? 32 GB 32 GB
SSD read cache opt No Yes – Fast cache Yes – Fast cache No Yes – Fast cache
Drive connectivity SAS 12 Gb/s 6 Gb/s 6 Gb/s 12 Gb/s 6 Gb/s
Host Protocols16 Gb FC / 1 & 10 Gb iSCSI /
10 Gb FCoE / 12 Gb SAS16 Gb FC / 1 Gb & 10 Gb iSCSI
/ No FCoE / No SAS8 Gb FC / 1 Gb & 10 Gb iSCSI
/ No FCoE / No SAS16 Gb FC / 1 & 10 Gb iSCSI / 10
Gb FCoE / 12 Gb SAS16 Gb FC / 1 Gb & 10 Gb iSCSI /
10 Gb FCoE / No SAS
NAS Available via MS WSS Available via MS WSS Yes (NFS, CIFS) Available via MS WSS Yes (NFS, CIFS) + Object
Efficiency features
High perf. thin prov. thin provisioning thin provisioning High perf. thin prov. thin provisioning
Easy Tier Opt.- Auto. Optional – Policy based Optional – Policy based Easy Tier Opt.- Auto. Optional – Policy based
No deduplication or compression
No deduplication or compression
File Dedup. & compress, not practical in small arrays
No deduplication or compressionDedup. & compression, not
practical in small arrays
IP Repl. w/ Acceleration IP Repl. w/ no Acceleration IP Repl. w/ no Acceleration IP Repl. w/ Acceleration IP Repl. w/ no Acceleration
Stg Pool Balancing / DRAID No? No? Stg Pool Balancing / DRAID No?
Local replicationIncluded up to 64, Opt. up to
2040 targetsIncluded Included
Included up to 64, Opt. up to 2040 targets
Optional
Data migration Included Optional Optional Included Optional
Remote Replication Optional Optional native Asynch. Native Async & via RecoverPoint Optional Optional via RecoverPoint
Represents real or perceived advantage over the other array
352016 Lenovo. All rights reserved.
Lenovo Storage V3700 V2 vs. Dell PowerVault MD3Technical comparison
Lenovo Storage V3700 V2Models C1D, C2D, EC1, EC2
Lenovo Storage V3700 V2Models C3D, C4D, EC3, EC4
Dell PowerVault MD3
Form factor / Height 2U 2U 2U (12 or 24 HDDs) / 4U (60 HDDs)
Controllers 2 2 1 or 2
Max number of drives 240 (SFF) / 120 (LFF) 240 (SFF) / 120 (LFF) 192 (2U) / 180 (4U enclosures)
Drive types 2.5"/3.5" SAS, NL SAS, Flash 2.5"/3.5" SAS, NL SAS, Flash 2.5"/3.5" SAS, NL SAS, Flash
Max capacity 480 TB (SFF) / 960 TB (LFF) 480 TB (SFF) / 960 TB (LFF) 96 TB / 1,440 TB (High density MD3x60) ??
Max cache memory 16 GB 32 GB 16 GB
SSD Based read cache option No No Yes
Raid levels 0, 1, 5, 6 & 10 0, 1, 5, 6 & 10 DDP (Dynamic Disk Pools)
Host Protocols16 Gb FC / 1 GB iSCSI / 10 Gb iSCSI / 10 Gb
FCoE / 12 Gb SASGreater port flexibility
16 Gb FC / 1 GB iSCSI / 10 Gb iSCSI / 10 Gb FCoE / 12 Gb SAS
Greater port flexibility
16 Gb FC / 1 Gb or 10 Gb iSCSI / No FCoE /12 Gb SAS
Distributed RAID Yes Yes DDP
Encryption No No Supports self-encrypting drives (SEDs)
Efficiency features
Thin Provisioning Thin Provisioning Thin Provisioning – (Real?)
Easy Tier – Fully Adaptive Easy Tier – Fully Adaptive No?
No deduplication or compression No deduplication or compression No deduplication or compression
Easy to use GUI Easy to use GUI GUI
IP Repl. with Acceleration IP Repl. with Acceleration IP Replication – No Acceleration
Storage Pool Balancing Storage Pool Balancing Dynamic Disk Rebalancing
Local replication Included up to 64, optional up to 2040 targets Included up to 64, optional up to 2040 targets Included up to 64, optional up to 512 targets
Data migration Included Included Only as a Service
Remote Replication Optional Optional Asynch. IP only, Synch. FC only
Represents real or perceived advantage over the other array
362016 Lenovo. All rights reserved.
Lenovo Storage V3700 V2 vs. Dell SCv2000 & SC4020Technical comparison
Lenovo Storage V3700 V2Models C1D, C2D, EC1, EC2
Lenovo Storage V3700 V2 Models C3D, C4D, EC3, EC4
Dell SCv2000 Dell SCv2020 Dell SCv2080 Dell SC4020
Form factor / Height 2U 2U 2U 2U 5U (high density)2U (control or exp) / 5U (high
density Exp)
Controllers 2 2 1 or 2 1 or 2 2 2
Max number of drives 240 (SFF) / 120 (LFF) 240 (SFF) / 120 (LFF) 168 168 168 192
Drive types 2.5"/3.5" SAS, NL SAS, Flash 2.5"/3.5" SAS, NL SAS, Flash2.5"/3.5" only 7.2K NL SAS
HDDs & Flash2.5"/3.5" SAS, NL SAS, Flash
2.5"/3.5" only 10K & 7.2K HDDs - SAS, NL SAS, Flash
2.5"/3.5" SAS, NL SAS, Flash
Max capacity 480 TB (2 TB HDD) / 960 TB 480 TB (2 TB HDD) / 960 TB 672 TB 672 TB 672 TB 1.054 PB
Max cache memory 16 GB 32 GB 16 GB 16 GB 16 GB 32 GB
SSD cache option No No No No No No?
Disk Connectivity 12 Gb/s 12 Gb/s 6 Gb/s 6 Gb/s 6 Gb/s 6 Gb/s
Host Protocols
16 Gb FC / 1 GB / 10 Gb iSCSI / 10 Gb FCoE / 12 Gb
SASGreater port flexibility
16 Gb FC / 1 GB / 10 Gb iSCSI / 10 Gb FCoE / 12 Gb SAS
Greater port flexibility
16 Gb FC / 1 Gb or 10 Gb iSCSI / no FCoE / 12 Gb
SASNo Port Intermix?
16 Gb FC / 1 Gb or 10 Gb iSCSI / no FCoE / 12 Gb SAS
No Port Intermix?
16 Gb FC / 1 Gb or 10 Gb iSCSI / no FCoE / 12 Gb SAS
No Port Intermix?
8 x 8 Gb FC or 8 x 10 GB iSCSI, no SAS
Can’t intermix FC & iSCSI?
Encryption No No No No No No
Efficiency features
Thin Provisioning Thin Provisioning Yes - “Dynamic Capacity” Yes - “Dynamic Capacity” Yes - “Dynamic Capacity” Yes - “Dynamic Capacity”
Easy Tier – Fully Adaptive Easy Tier – Fully Adaptive Data Progression Data Progression Data Progression Data Progression
No Dedup. or compression No Dedup. or compression No No No No dedup, compression?
Easy to use GUI Easy to use GUI GUI GUI GUI GUI
IP Repl. with Acceleration IP Repl. with Acceleration IP Repl – No Acceler. IP Repl – No Acceler. IP Repl – No Acceler. IP Replic – No Accel,.
Storage Pool Balancing Storage Pool Balancing Yes Yes Yes Yes
Local replicationIncluded up to 64, optional up
to 2040 targetsIncluded up to 64, optional up to
2040 targetsUp to 2000 Targets Up to 2000 Targets Up to 2000 Targets Yes, up to ?
Data migration Included Included As a service? As a service? As a service? As a service?
Remote Replication Optional Optional Optional Optional Optional No Asynch (long distance)?
Represents real or perceived advantage over the other array
372016 Lenovo. All rights reserved.
Lenovo Storage V3700 V2 vs. HP 3PAR 7200c & 8200Technical comparison
Lenovo Storage V3700 V2Models C1D, C2D, EC1, EC2
Lenovo Storage V3700 V2Models C3D, C4D, EC3, EC4
HP 3PAR 7200c HP 3PAR 8200
Form factor / Height 2U 2U 2U or 4U (LFF Expansion) 2U or 4U (LFF Expansion)
Controllers 2 2 2 2
Max number of drives 240 (SFF) / 120 (LFF) 240 (SFF) / 120 (LFF) 240 (SFF) 240
Drive types 2.5"/3.5" SAS, NL SAS, SSD 2.5"/3.5" SAS, NL SAS, SSD 2.5"/3.5" SAS, NL SAS, SSD 2.5"/3.5" SAS, NL SAS, SSD
Max capacity 480 TB / 960 TB (Max 8 TB HDD) 480 TB / 960 TB (Max 8 TB HDD) 500 TB (Max 6 TB HDD) 750 TiB (Max 8 TB HDD)
Max cache memory 16 GB 32 GB 40 GB 64 GB
SSD Based read cache No No Yes Yes to 768 GiB
Drive Connectivity 12 Gb/s 12 Gb/s 6 Gb/s 12 Gb/s
Host Protocols16 Gb FC / 1 Gb & 10 Gb iSCSI / 10 Gb
FCoE / 12 Gb SASMicrosoft WSS for File access
16 Gb FC / 1 Gb & 10 Gb iSCSI / 10 Gb FCoE / 12 Gb SAS
Microsoft WSS for File access
16 Gb FC / 1 Gb & 10 Gb iSCSI / FCoE / No SAS
It supports File & Object access
16 Gb FC / 1 Gb & 10 Gb iSCSI / FCoE / No SAS
It supports File & Object access
Ports: FC / iSCSI / FCoE / SAS8 / 4* + 8 / 8 / 8* Standard ports
8 / 4* + 8 / 8 / 4* + 8* Standard ports
12 or 4 / 4 / 0 / 0 4 - 12 / 4 / 4 / 0
Encryption No No Yes (SEDs) Yes (SEDs)
Efficiency features
thin provisioning thin provisioning thin provisioning thin provisioning
Easy Tier – Fully Adaptive Easy Tier – Fully Adaptive Yes - “Adaptive Optimization” Yes - “Adaptive Optimization”
No deduplication or compression No deduplication or compressionHas deduplication but no compression
(“compaction”?)Has deduplication but no compression
(“compaction”?)
Easy to use XIV GUI Easy to use XIV GUI GUI GUI
IP Repl. with Acceleration IP Repl. with Acceleration IP Repl. NO Acceleration IP Repl. NO Acceleration
Storage Pool Balancing Storage Pool Balancing Yes? Yes?
Local replicationIncluded up to 64 targets, optional up to
2040 targetsIncluded up to 64 targets, optional up to
2040 targetsYes – Up to ? Yes – Up to ?
Data migration Included Included 1 year online migration 1 year online migration
Remote Replication Optional Optional Optional Optional
Represents real or perceived advantage over the other array
382016 Lenovo. All rights reserved.
Lenovo Storage V3700 V2 vs. HP MSA 1040 & 2040Technical comparison
Lenovo Storage V3700 V2Models C1D, C2D, EC1, EC2
Lenovo Storage V3700 V2 Models C3D, C4D, EC3, EC4
HP MSA 1040 HP MSA 2040
Form factor / Height 2U 2U 2U 2U
Controllers 2 2 1 or 2 1 or 2
Max number of drives 240 (SFF) / 120 (LFF) 240 (SFF) / 120 (LFF) 99 (SFF) / 48 (LFF) 199 (SFF) / 96 (LFF)
Drive types 2.5"/3.5" SAS, NL SAS, SSD 2.5"/3.5" SAS, NL SAS, SSD 2.5"/3.5" SAS, NL SAS, SSD 2.5"/3.5" SAS, NL SAS, SSD
Max capacity 480 TB / 960 TB (8 TB HDD) 480 TB / 960 TB (8 TB HDD) 178 TB / 384 TB 358 TB / 768 TB
Max cache memory 16 GB 32 GB 8 GB 8 GB
SSD Based read cache option No No Yes Yes
Disk Connectivity (SAS) 12 Gb/s 12 Gb/s 6 Gb/s 6 Gb/s
Host Protocols16 Gb FC / 1 GB iSCSI / 10 Gb iSCSI /
10 Gb FCoE / 12 Gb SASGreater flexibility of ports
16 Gb FC / 1 GB iSCSI / 10 Gb iSCSI / 10 Gb FCoE / 12 Gb SASGreater flexibility of ports
8 Gb FC / 1 Gb or 10 Gb iSCSI / 12 Gb SAS / No FCoE
Can’t intermix ports
16 Gb FC / 1 GB or 10 Gb iSCSI / No FCoE / 12 Gb SAS
Can’t intermix SAS w/other ports
Ports: FC / iSCSI / FCoE / SAS8 / 4* + 8 / 8 / 8* Standard ports
8 / 4* + 8 / 8 / 4* + 8* Standard ports
4 / 4 or 4 / 0 / 4 8 / 8 / 8 / 0 OR 8 SAS
Encryption No No No Supports self-encrypting drives
Efficiency features
thin provisioning thin provisioning thin provisioning – New thin provisioning – New
Easy Tier – Fully Adaptive Easy Tier – Fully Adaptive “Performance” / “Archive” Tiering “Performance” / “Archive” Tiering
No deduplication or compression No deduplication or compression No deduplication or compression No deduplication or compression
Easy to use GUI Easy to use GUI GUI GUI
IP Repl. with Acceleration IP Repl. with Acceleration IP Replication – No Acceleration IP Replication – No Acceleration
Storage Pool Balancing Storage Pool Balancing Wide Striping Wide Striping
Local replicationIncluded up to 64 targets, optional up to
2040 targetsIncluded up to 64 targets, optional up to
2040 targetsIncluded up to 64 targets, optional up
to 512 targetsIncluded up to 64 targets, optional up
to 512 targets
Data migration Included Included Only as a Service Only as a Service
Remote Replication Optional Optional Asynchronous only Optional (old code only)
Represents real or perceived advantage over the other array
39
IBM SSIC will not be utilized for Lenovo branded V Series
• Exception : IBM will show support on SSIC for Lenovo Storage V3700 V2 and V5030 as virtualization targets for Storwize
Interop resources will follow what provided for S Series• Options Compatibility Matrix (updated monthly) – posted on support site• V Series Interoperability Matrix – posted on support site and linked from Product Guide
Storage - Option Compatibility Matrix
2016 Lenovo. All rights reserved.
V3700 V2 - Interoperabilität
402016 Lenovo. All rights reserved.
Lenovo and IBM Intermix & Connectivity Rules
What you CAN do
• Clustering – You can cluster a V5000 (Gen 1) purchased from Lenovo with a Lenovo Storage V5030 (Gen 2)
� They must both be sourced from Lenovo. No clustering across vendors.
• Virtualization - Virtualization can go across Gen 1 and Gen 2, as well as across IBM and Lenovo� An IBM Storwize V5000, V5030 or V7000 can virtualize a Lenovo V Series Gen 1 or Gen 2 array, and
� A Lenovo Storwize V5000, V7000 or Lenovo Storage V5030 can virtualize an IBM Storwize product.
• Remote Replication - Remote replication can be between Gen. 1 and Gen. 2, as well as across IBM and Lenovo� IBM Storwize arrays can be connected to a Lenovo V Series array via the Remote Replication features of each of them
ReplicateIBM / Lenovo Gen 1 / 2
Virtualize
IBM / Lenovo or other storage arrays in the market!
IBM / Lenovo Gen 1 / 2
412016 Lenovo. All rights reserved.
Lenovo and IBM Intermix & Connectivity Rules
What you CANNOT do• No intermix of IBM and Lenovo enclosures, parts or features are allowed.
o If a Storwize system is an IBM Machine Type (e.g.: V3700 = 2072), then ALL options and expansion enclosures must be ordered from IBM
o If a Storage system is a Lenovo Machine Type (e.g.: V3700 = 6099), then ALL options and expansion enclosures must be ordered from Lenovo
• No intermix of Lenovo Storwize V3500/V3700/V5000 (Gen 1) and Lenovo Storage V3700 V2/V5030 (Gen 2) parts are allowed, excepto Power cords, FC host cables
• No intermix of unique parts between the Lenovo Storage V3700 V2 modelso Advanced Function activation keys (PNs differ between V3700 V2 models)
• Storwize V5000 and Lenovo Storage V5030 - no transfers of SW licenses from one box to another. SW licenses are attached to the serial number of an enclosureo The only exception would be for SW licenses for External Virtualization which correspond to an external storage device. If the
Lenovo Storwize V5000 or Lenovo Storage V5030 that is virtualizing that external storage is changed, the licenses for externalvirtualization attached to that external device can be transferred.
422016 Lenovo. All rights reserved.
V3700 V2 - InformationenLenovo Storage V3700 V2 and V3700 V2 XP Product Guide:
https://lenovopress.com/lp0497-lenovo-storage-v3700-v2-and-v3700-v2-xp
Dokumentation:http://support.lenovo.com/us/en/products/Servers/Lenovo-Storage/v3700v2?tabName=Documentation
Support: http://support.lenovo.com/us/en/products/Servers/Lenovo-Storage/v3700v2
Interoperability Matrix - Lenovo Storage V3700 V2:https://download.lenovo.com/pccbbs/thinkservers/lenovo_storage_v3700v2_v7.6.1.x.xls
Options Compatibility Matrix (for Accessories):https://download.lenovo.com/pccbbs/options_iso/ocm_august_2016_storage.xlsx