BARR & CLARK Independent Environmental Testing

Asbestos • Lead • Mold • Phase I

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

LEAD-BASED PAINT INSPECTION REPORT

OF

TEMPLE CITY LIBRARY

5939 GOLDEN WEST AVENUE

TEMPLE CITY, CA

PROJECT NO. 3014044

JUNE 10, 2019

Prepared For:

emar Studio

3341 Helms Avenue

Culver City, CA 90232

Prepared By: Reviewed By:

Jeremy Nguyen Matt Crochet

State of California Certified State of California Certified

Lead Inspector / Risk Assessor Lead Inspector / Risk Assessor

Page 3: LEAD-BASED PAINT INSPECTION REPORT

Lead-Based Paint Inspection Report

Temple City Library

5939 Golden West Avenue

Project Number: 3014044

Page 2

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

TABLE OF CONTENTS

DESCRIPTION PAGE NO.

1.0 INTRODUCTION .......................................................................................................... 3

2.0 SCOPE OF WORK ......................................................................................................... 3

3.0 PROPERTY DESCRIPTION ......................................................................................... 3

4.0 INSPECTOR’S QUALIFICATIONS ............................................................................. 3

5.0 TESTING PROTOCOL .................................................................................................. 3

6.0 METHOD OF TESTING ................................................................................................ 4

7.0 SUMMARY OF RESULTS ........................................................................................... 5

8.0 RECOMMENDATIONS ................................................................................................ 5

9.0 INSPECTION LIMITATIONS ...................................................................................... 6

APPENDICES

APPENDIX A SUMMARIES

LEAD CONTAINING COMPONENTS LIST

XRF FIELD DATA

APPENDIX B CDPH 8552

INSPECTOR’S CERTIFICATE(S)

INSURANCE CERTIFICATE

APPENDIX C MAP(S)

Page 4: LEAD-BASED PAINT INSPECTION REPORT

Lead-Based Paint Inspection Report

Temple City Library

5939 Golden West Avenue

Project Number: 3014044

Page 3

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

LEAD-BASED PAINT INSPECTION REPORT

1.0 INTRODUCTION

This report presents the results of Barr & Clark Environmental’s lead-based paint (LBP) inspection of the

Temple City Library located at 5939 Golden West Avenue, Temple City, California (Subject Property).

This document is prepared for the sole use of emar Studio, and any regulatory agencies that are directly

involved in this project. No other party should rely on the information contained herein without prior

written consent of emar Studio. The scope of services, inspection methodology, and results are presented

below.

2.0 SCOPE OF WORK

The purpose of this inspection is to identify and assess the Lead-Based Paint (LBP) present on painted

components at the subject property.

On June 04, 2019, Barr & Clark performed an inspection for lead-based paint at the subject property in

Temple City, California. To comply with EPA and HUD guidelines, painted and varnished surfaces in

every accessible “room equivalent” were sampled for the presence of LBP. The intent was to ascertain

the presence of lead-based paint above the federal action level. If LBP was found, the inspection would

identify individual architectural components and their respective concentrations of lead in such a manner

that this report would be used to characterize the presence of LBP at this property.

3.0 PROPERTY DESCRIPTION

The subject property is a library that was built circa 1960. It is a one-story building that is constructed

over a basement. The exterior walls are covered with stucco and brick and all of the windows are fixed

types. At the time of this inspection, most of the painted surfaces were in good condition.

4.0 INSPECTOR’S QUALIFICATIONS

Jeremy Nguyen of Barr & Clark performed the inspection at the site using an RMD LPA-1 XRF

spectrum analyzer instrument. He has attended the radiation safety course for handling the instrument,

and completed an EPA approved curriculum in Lead in Construction Inspector / Risk Assessor Training.

At the time of this report, the California Department of Health Services, Childhood Lead Poisoning

Branch, has implemented a State Certification Model Accreditation Plan adopted from the EPA. Jeremy

Nguyen has received certification. Personnel certificate(s) have been provided in Appendix B.

5.0 TESTING PROTOCOL

XRF Testing: Testing of the painted surfaces was patterned after the inspection protocol in Chapter 7 of

the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing1. In every

“room equivalent” within the tested property, one representative surface of each “testing combination”

was tested. Multiple readings were collected to resolve inconsistencies in the test results.

1 2012 Revision

Page 5: LEAD-BASED PAINT INSPECTION REPORT

Lead-Based Paint Inspection Report

Temple City Library

5939 Golden West Avenue

Project Number: 3014044

Page 4

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

Regulatory Compliance: Several public (government) agencies have a published “regulatory action

level” to classify LBP. To further complicate matters, some of the established “levels” are quantified in

different units of measurement. Listed below are the current regulatory agencies that have defined LBP,

along with the respective action level: Agency Ordinance # Action level (mg / cm2) Action level (ppm2) HUD / EPA 24 CFR 35.86 & 40 CFR 745.103 1.0 mg / cm2 5,000 ppm

L.A. County Title 11, 11.28.010 0.7 mg / cm2 600 ppm3

OSHA / CAL OSHA 29 CFR 1926.62 & Title 8, 1532.1 Not Specified 600 ppm4 HUD / EPA have recently issued the following guidance regarding units of measurement for paint samples: “Report lead paint amounts in mg/cm² because this unit of measurement does not depend on the number of layers of non-lead-

based paint and can usually be obtained without damaging the painted surface. All measurements of lead in paint should be in

mg/cm², unless the surface area cannot be measured or if all paint cannot be removed from the measured surface area. In such

cases, concentrations may be reported in weight percent (%) or parts per million by weight (ppm).”5 Furthermore, EPA has previously issued guidance on lead content classification as follows: “… The rule, at 24 CFR 35.86 and 40 CFR 745.103 states that a lead-based paint free finding must demonstrate that the

building is free of ‘paint or other surface coatings that contain lead in excess of 1.0 milligrams per square centimeter (1.0 mg /

cm2) or 0.5 percent by weight (5000 ppm).’ The State standards are not applicable, whether more or less stringent, since a

State cannot amend Federal requirements.”6

In recognition of the various action levels the testing results are classified as follows for this report:

• Painted surfaces with readings at or above 0.7 mg / cm2 are considered - Positive

• Painted surfaces with readings at or below 0.6 mg / cm2 are considered - Negative

The individual readings have been provided on all field data sheets. Any future change in action levels

by one of the regulating agencies may affect the classification of results.

6.0 METHOD OF TESTING

Paint Testing: The method employed was X-ray fluorescence (XRF) using a Radiation Monitoring

Device Lead Paint Analyzer (RMD LPA-1). The instrument was operated in “Quick Mode,” where the

duration for each test result is determined by a combination of:

• the actual reading relative to the designated action level;

• the age of the radioactive source; and

• the substrate on which the test was taken.

The instrument’s calibration was verified according to the manufacturer's specifications in compliance

with the Performance Characteristic Sheet (PCS) developed for this instrument.

The readings from this instrument produce a 95% confidence level that the “lead” reading accurately

reflects the actual level of lead in the tested surfaces, relative to the federal action level.

2 Parts per million

3 Applies to sale and application of LBP.

4 Applies to construction related activities 5 Chapter 7 of the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (2012 Revision).

6 Office of Pollution Prevention and Toxics, (August 20, 1996)

Page 6: LEAD-BASED PAINT INSPECTION REPORT

Lead-Based Paint Inspection Report

Temple City Library

5939 Golden West Avenue

Project Number: 3014044

Page 5

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

7.0 SUMMARY OF RESULTS

Paint Sampling: Throughout the subject property, several of the painted components indicated the

presence of lead-based paint (LBP) at or above the action level. The following summary lists the specific

components that tested above the action level and their respective locations:

Interior

• Room 1 – columns

• Room 6 – columns

• Some of the tiled surfaces in the restrooms also tested positive for lead. These surfaces were not

painted and the lead is most likely in the glazing or the matrix of the tile itself.

Sampling for this inspection was representative and any components that were not tested but similar to

those components that tested positive for LBP should be considered and treated as lead laden.

The field data and results for paint sampling may be found in Appendix A.

8.0 RECOMMENDATIONS

The greatest potential for lead exposure from lead painted architectural components occurs when:

• the paint has become defective; or

• when the paint is applied to a friction / impact component where the paint is continually

disturbed; or

• when the paint is disturbed through routine maintenance or renovation activities.

With this in mind, the following are our recommendations for this property:

• The results from this inspection should be provided to any individuals that may disturb the painted

surfaces. It is encouraged to utilize professionals that have experience working with LBP.

• If renovation is scheduled in the near future (less than three months), all lead painted components that

have been previously targeted for replacement should be replaced utilizing “lead safe” containment

and work practices.

• ALL components that have been identified with defective lead paint should have the paint repaired as

soon as possible. Any paint repair should be done utilizing “lead safe” containment, work practices,

and clean-up techniques.

• All components with lead painted friction / impact surfaces should be treated to minimize the friction

or impact as necessary.

• Lead painted components that have not been targeted for replacement should either be considered for

abatement (replacement, enclosure, encapsulation, etc.) or included in an Operations & Management

(O & M) Plan that will help to minimize exposures to lead hazards.

• All lead painted surfaces that are not expected to be impacted in the near future (less than three

months) should also be included the O & M plan.

• In addition, the tenants or occupants of the dwelling should be notified of the test results and

instructed in actions that they may perform to keep the living areas “lead safe.”

• The tile surfaces are not a likely source of lead dust contamination as long as they remain intact. If

future renovation or repair activities require that the tile be removed, or the surfaces disturbed, it

should be done in a manner that does not break the tiles. If this is not feasible, this task should be

assigned to a lead certified contractor.

Page 7: LEAD-BASED PAINT INSPECTION REPORT

Lead-Based Paint Inspection Report

Temple City Library

5939 Golden West Avenue

Project Number: 3014044

Page 6

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

9.0 INSPECTION LIMITATIONS

This inspection was planned, developed, and implemented based on Barr & Clark’s previous experience

in performing lead-based paint inspections. This inspection was patterned after Chapter 7 of the HUD

Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (2012 Revision).

Barr & Clark utilized state-of-the-art-practices and techniques in accordance with regulatory standards

while performing this inspection. Barr & Clark’s evaluation of the relative risk of exposure to lead

identified during this inspection is based on conditions observed at the time of the inspection. Barr &

Clark cannot be responsible for changing conditions that may alter the relative exposure risk or for future

changes in accepted methodology. Enclosed are the diagram(s), actual test results, and all relevant

certifications and licenses.

Page 8: LEAD-BASED PAINT INSPECTION REPORT

APPENDIX

A XRF FIELD DATA

Page 9: LEAD-BASED PAINT INSPECTION REPORT

Acoustic Ceiling 66 0 100.00%

Brick Wall 1212 0 100.00%

Concrete Ceiling 22 0 100.00%

Concrete Column 11 0 100.00%

Concrete Wall 1010 0 100.00%

Gypsum Ceiling 22 0 100.00%

Gypsum Wall 2626 0 100.00%

Metal Beam 11 0 100.00%

Metal Column 02 2 100.00%

Metal Door 33 0 100.00%

Metal Door Frame 1414 0 100.00%

Metal Electrical Panel 44 0 100.00%

Metal Fire Ext. Box 22 0 100.00%

Metal Handrail 11 0 100.00%

Metal Heater Vent 1111 0 100.00%

Metal Pipe 11 0 100.00%

Metal Railing 11 0 100.00%

Metal Stringer 11 0 100.00%

Metal Window Frame 99 0 100.00%

Plaster Ceiling 88 0 100.00%

Plaster Wall 4040 0 100.00%

Tile Baseboard 01 1 100.00%

Tile Floor 44 0 100.00%

Tile Wall 09 9 100.00%

Wood Baseboard 22 0 100.00%

Wood Beam 33 0 100.00%

Wood Cabinet Door 44 0 100.00%

Wood Cabinet Frame 44 0 100.00%

Wood Cabinet Shelf 44 0 100.00%

Wood Closet Door 11 0 100.00%

Wood Closet Door Frame 11 0 100.00%

Wood Door 2020 0 100.00%

Wood Door Frame 1111 0 100.00%

Wood Wall 44 0 100.00%

225 12 213Totals:

SUMMARY OF INTERIORTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City CA, 91780

Project Number:3014044

ComponentNumberTested

NumberPositive Percent Positive

NumberNegative Percent Negative

1 6/5/2019 11:41:48 AMBarr & Clark Environmental (714) 894-5700

Testing done in compliance with current L.A. County DHS guidelines for XRF.

Page 10: LEAD-BASED PAINT INSPECTION REPORT

Asphalt Parking Stripe 22 0 100.00%

Brick Column 11 0 100.00%

Brick Wall 1313 0 100.00%

Concrete Curb 11 0 100.00%

Metal Awning 22 0 100.00%

Metal Bollard 33 0 100.00%

Metal Column 11 0 100.00%

Metal Door 33 0 100.00%

Metal Door Frame 99 0 100.00%

Metal Downspout 44 0 100.00%

Metal Gutter 22 0 100.00%

Metal Ramp 11 0 100.00%

Metal Trim 11 0 100.00%

Metal Vent 22 0 100.00%

Metal Window Frame 99 0 100.00%

Stucco Ceiling 33 0 100.00%

Stucco Wall 33 0 100.00%

Tile Floor 11 0 100.00%

Wood Beam 33 0 100.00%

Wood Door 77 0 100.00%

Wood Door Frame 11 0 100.00%

Wood Fascia 44 0 100.00%

76 0 76Totals:

SUMMARY OF EXTERIORTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City CA, 91780

Project Number:3014044

ComponentNumberTested

NumberPositive Percent Positive

NumberNegative Percent Negative

2 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

Testing done in compliance with current L.A. County DHS guidelines for XRF.

Page 11: LEAD-BASED PAINT INSPECTION REPORT

Wood 0.0 mg/cm2 Standard 66 0 100.00%

Wood 1.0 mg/cm2 Standard 06 6 100.00%

12 6 6Totals:

SUMMARY OF COMMONTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City CA, 91780

Project Number:3014044

ComponentNumberTested

NumberPositive Percent Positive

NumberNegative Percent Negative

3 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

Testing done in compliance with current L.A. County DHS guidelines for XRF.

Page 12: LEAD-BASED PAINT INSPECTION REPORT

LEADCONTAINING

COMPONENTSLIST

Page 13: LEAD-BASED PAINT INSPECTION REPORT

31 Interior Room 1 Intact1.8Metal Column POSITIVE66 Interior Men's Restroom Intact14.0A Tile Wall POSITIVE67 Interior Men's Restroom Intact15.0B Tile Wall POSITIVE68 Interior Men's Restroom Intact15.0C Tile Wall POSITIVE69 Interior Men's Restroom Intact14.0D Tile Wall POSITIVE75 Interior Women's Restroom Intact15.0A Tile Wall POSITIVE76 Interior Women's Restroom Intact14.0B Tile Wall POSITIVE77 Interior Women's Restroom Intact15.0C Tile Wall POSITIVE78 Interior Women's Restroom Intact15.0D Tile Wall POSITIVE99 Interior Room 6 Intact1.2Metal Column POSITIVE

146 Interior Restroom 1 Intact15.0C Tile Wall POSITIVE148 Interior Restroom 1 Intact12.0Tile Baseboard POSITIVE

Interior Lead Containing Components ListTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Room EquivalentSide Testing Combination ConditionLead Results Comments

1 of 2 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 14: LEAD-BASED PAINT INSPECTION REPORT

4 Calibration Common Start of Job Intact1.0Wood 1.0 mg/cm2 Standard POSITIVE5 Calibration Common Start of Job Intact1.0Wood 1.0 mg/cm2 Standard POSITIVE6 Calibration Common Start of Job Intact1.1Wood 1.0 mg/cm2 Standard POSITIVE

311 Calibration Common End of Job Intact1.0Wood 1.0 mg/cm2 Standard POSITIVE312 Calibration Common End of Job Intact1.2Wood 1.0 mg/cm2 Standard POSITIVE313 Calibration Common End of Job Intact1.2Wood 1.0 mg/cm2 Standard POSITIVE

Common Lead Containing Components ListTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Room EquivalentSide Testing Combination ConditionLead Results Comments

2 of 2 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 15: LEAD-BASED PAINT INSPECTION REPORT

FIELD DATA

Page 16: LEAD-BASED PAINT INSPECTION REPORT

Calibration1 Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.1 NegativeCalibration2 Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.0 NegativeCalibration3 Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.2 NegativeCalibration4 Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVECalibration5 Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVECalibration6 Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.1 POSITIVE

7 Exterior Room 1 B Door Metal Intact 0.0 Negative8 Exterior Room 1 B Door Frame Metal Intact 0.0 Negative9 Interior Room 1 B Door Metal Intact 0.1 Negative

10 Interior Room 1 B Door Frame Metal Intact 0.1 Negative11 Interior Room 1 A Window Frame Metal Intact 0.0 Negative Fixed12 Interior Room 1 A Window Frame Metal Intact 0.1 Negative Fixed13 Interior Room 1 A Window Frame Metal Intact 0.1 Negative Fixed14 Interior Room 1 B Window Frame Metal Intact 0.0 Negative Fixed15 Interior Room 1 B Window Frame Metal Intact 0.1 Negative Fixed16 Interior Room 1 B Window Frame Metal Intact 0.1 Negative Fixed17 Interior Room 1 B Window Frame Metal Intact 0.0 Negative Fixed18 Interior Room 1 B Window Frame Metal Intact 0.2 Negative Fixed19 Interior Room 1 B Window Frame Metal Intact 0.1 Negative Fixed20 Interior Room 1 A Wall Plaster Intact 0.0 Negative21 Interior Room 1 B Wall Plaster Intact 0.2 Negative22 Interior Room 1 C Wall Wood Intact 0.1 Negative23 Interior Room 1 D Wall Plaster Intact 0.2 Negative24 Interior Room 1 A Wall Brick Intact 0.0 Negative25 Interior Room 1 B Wall Brick Intact 0.1 Negative26 Interior Room 1 D Wall Brick Intact 0.0 Negative27 Interior Room 1 A Wall Wood Intact 0.0 Negative28 Interior Room 1 Heater Vent Metal Intact 0.0 Negative29 Interior Room 1 Ceiling Acoustic Intact 0.2 Negative 1x1 Tiles

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

1 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 17: LEAD-BASED PAINT INSPECTION REPORT

30 Interior Room 1 Floor Tile Intact 0.1 Negative31 Interior Room 1 Column Metal Intact 1.8 POSITIVE32 Interior Room 1 Beam Wood Intact 0.2 Negative33 Interior Room 1 Beam Wood Intact 0.2 Negative At Front Counter34 Exterior Room 2 D Door Wood Intact 0.3 Negative35 Exterior Room 2 D Door Frame Metal Intact 0.5 Negative36 Interior Room 2 D Door Wood DETERIORATED 0.0 Negative37 Interior Room 2 D Door Frame Metal Intact 0.4 Negative38 Interior Room 2 A Door Wood Intact 0.0 Negative39 Interior Room 2 A Door Frame Wood Intact 0.1 Negative40 Interior Room 2 C Closet Door Wood Intact 0.0 Negative41 Interior Room 2 C Closet Door Frame Wood Intact 0.1 Negative42 Interior Room 2 A Wall Wood Intact 0.0 Negative43 Interior Room 2 B Wall Brick Intact 0.0 Negative44 Interior Room 2 C Wall Brick Intact 0.2 Negative45 Interior Room 2 D Wall Wood Intact 0.1 Negative46 Interior Room 2 Baseboard Wood Intact 0.0 Negative47 Interior Room 2 D Heater Vent Metal Intact 0.0 Negative48 Interior Room 2 Ceiling Acoustic Intact 0.2 Negative 1x1 Tiles49 Interior Room 3 A Door Frame Wood Intact 0.0 Negative50 Interior Room 3 A Wall Plaster Intact 0.0 Negative51 Interior Room 3 B Wall Plaster Intact 0.0 Negative52 Interior Room 3 C Wall Plaster Intact 0.2 Negative53 Interior Room 3 D Wall Plaster Intact 0.1 Negative54 Interior Room 3 Heater Vent Metal Intact 0.0 Negative55 Interior Room 3 Ceiling Plaster Intact 0.2 Negative56 Interior Room 4 D Door Wood Intact 0.0 Negative57 Interior Room 4 D Door Frame Wood Intact 0.1 Negative58 Interior Room 4 A Wall Plaster Intact 0.0 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

2 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 18: LEAD-BASED PAINT INSPECTION REPORT

59 Interior Room 4 B Wall Plaster Intact 0.0 Negative60 Interior Room 4 C Wall Plaster Intact 0.1 Negative61 Interior Room 4 D Wall Plaster Intact 0.0 Negative62 Interior Room 4 Ceiling Plaster Intact 0.0 Negative63 Interior Room 4 A Electrical Panel Metal Intact 0.0 Negative64 Interior Men's Restroom A Door Wood Intact 0.0 Negative65 Interior Men's Restroom A Door Frame Wood Intact 0.1 Negative66 Interior Men's Restroom A Wall Tile Intact 14.0 POSITIVE67 Interior Men's Restroom B Wall Tile Intact 15.0 POSITIVE68 Interior Men's Restroom C Wall Tile Intact 15.0 POSITIVE69 Interior Men's Restroom D Wall Tile Intact 14.0 POSITIVE70 Interior Men's Restroom Heater Vent Metal Intact 0.0 Negative71 Interior Men's Restroom Ceiling Plaster Intact 0.2 Negative72 Interior Men's Restroom Floor Tile Intact 0.2 Negative73 Interior Women's

RestroomA Door Wood Intact 0.0 Negative

74 Interior Women's Restroom

A Door Frame Wood Intact 0.1 Negative

75 Interior Women's Restroom

A Wall Tile Intact 15.0 POSITIVE

76 Interior Women's Restroom

B Wall Tile Intact 14.0 POSITIVE

77 Interior Women's Restroom

C Wall Tile Intact 15.0 POSITIVE

78 Interior Women's Restroom

D Wall Tile Intact 15.0 POSITIVE

79 Interior Women's Restroom

Heater Vent Metal Intact 0.0 Negative

80 Interior Women's Restroom

Ceiling Plaster Intact 0.2 Negative

81 Interior Women's Restroom

Floor Tile Intact 0.1 Negative

82 Exterior Room 5 D Door Wood Intact 0.0 Negative83 Exterior Room 5 D Door Frame Metal Intact 0.1 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

3 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 19: LEAD-BASED PAINT INSPECTION REPORT

84 Interior Room 5 D Door Wood Intact 0.1 Negative85 Interior Room 5 D Door Frame Metal Intact 0.3 Negative86 Interior Room 5 B Door Wood Intact 0.0 Negative87 Interior Room 5 B Door Frame Wood Intact 0.2 Negative88 Interior Room 5 A Wall Plaster Intact 0.0 Negative89 Interior Room 5 B Wall Plaster Intact 0.1 Negative90 Interior Room 5 C Wall Plaster Intact 0.2 Negative91 Interior Room 5 D Wall Brick Intact 0.1 Negative92 Interior Room 5 Ceiling Plaster Intact 0.2 Negative93 Interior Room 6 A Wall Plaster Intact 0.3 Negative94 Interior Room 6 C Wall Plaster Intact 0.3 Negative95 Interior Room 6 D Wall Plaster Intact 0.2 Negative96 Interior Room 6 Heater Vent Metal Intact 0.0 Negative97 Interior Room 6 Ceiling Acoustic Intact 0.2 Negative 1x1 Tiles98 Interior Room 6 Beam Wood Intact 0.2 Negative99 Interior Room 6 Column Metal Intact 1.2 POSITIVE

100 Interior Room 6 A Electrical Panel Metal Intact 0.0 Negative101 Interior Room 6 A Fire Ext. Box Metal Intact 0.2 Negative102 Interior Room 7 B Door Wood Intact 0.0 Negative103 Interior Room 7 B Door Frame Wood Intact 0.1 Negative104 Interior Room 7 A Wall Plaster Intact 0.0 Negative105 Interior Room 7 B Wall Plaster Intact 0.2 Negative106 Interior Room 7 C Wall Plaster Intact 0.2 Negative107 Interior Room 7 D Wall Brick Intact 0.3 Negative108 Interior Room 7 Heater Vent Metal Intact 0.0 Negative109 Interior Room 7 Ceiling Acoustic Intact 0.1 Negative 1x1 Tiles110 Exterior Room 8 D Door Metal Intact 0.0 Negative111 Exterior Room 8 D Door Frame Wood Intact 0.1 Negative112 Interior Room 8 D Door Metal Intact 0.1 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

4 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 20: LEAD-BASED PAINT INSPECTION REPORT

113 Interior Room 8 D Door Frame Wood Intact 0.3 Negative114 Interior Room 8 B Door Frame Wood Intact 0.0 Negative115 Interior Room 8 A Cabinet Frame Wood Intact 0.0 Negative116 Interior Room 8 A Cabinet Door Wood Intact 0.2 Negative117 Interior Room 8 A Cabinet Shelf Wood Intact 0.1 Negative118 Interior Room 8 B Cabinet Frame Wood Intact 0.0 Negative119 Interior Room 8 B Cabinet Door Wood Intact 0.1 Negative120 Interior Room 8 B Cabinet Shelf Wood Intact 0.1 Negative121 Interior Room 8 A Wall Plaster Intact 0.0 Negative122 Interior Room 8 B Wall Plaster Intact 0.3 Negative123 Interior Room 8 C Wall Plaster Intact 0.3 Negative124 Interior Room 8 D Wall Brick Intact 0.2 Negative125 Interior Room 8 Heater Vent Metal Intact 0.2 Negative126 Interior Room 8 Ceiling Acoustic Intact 0.1 Negative 1x1 Tiles127 Interior Room 8 C Fire Ext. Box Metal Intact 0.0 Negative128 Interior Room 9 C Door Wood Intact 0.0 Negative129 Interior Room 9 C Door Frame Wood Intact 0.1 Negative130 Interior Room 9 A Wall Brick Intact 0.0 Negative131 Interior Room 9 B Wall Plaster Intact 0.2 Negative132 Interior Room 9 C Wall Plaster Intact 0.1 Negative133 Interior Room 9 D Wall Plaster Intact 0.1 Negative134 Interior Room 9 Heater Vent Metal Intact 0.0 Negative135 Interior Room 9 Ceiling Acoustic Intact 0.1 Negative 1x1 Tiles136 Interior Room 10 A Wall Brick Intact 0.0 Negative137 Interior Room 10 B Wall Plaster Intact 0.2 Negative138 Interior Room 10 C Wall Plaster Intact 0.1 Negative139 Interior Room 10 D Wall Plaster Intact 0.1 Negative140 Interior Room 10 Ceiling Plaster Intact 0.0 Negative141 Interior Room 10 Pipe Metal Intact 0.0 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

5 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 21: LEAD-BASED PAINT INSPECTION REPORT

142 Interior Restroom 1 A Door Wood Intact 0.0 Negative143 Interior Restroom 1 A Door Frame Metal Intact 0.1 Negative144 Interior Restroom 1 A Wall Plaster Intact 0.0 Negative145 Interior Restroom 1 B Wall Plaster Intact 0.2 Negative146 Interior Restroom 1 C Wall Tile Intact 15.0 POSITIVE147 Interior Restroom 1 D Wall Plaster Intact 0.0 Negative148 Interior Restroom 1 Baseboard Tile Intact 12.0 POSITIVE149 Interior Restroom 1 Ceiling Plaster Intact 0.0 Negative150 Interior Restroom 1 Floor Tile Intact 0.2 Negative151 Exterior Room 11 D Door Wood Intact 0.0 Negative152 Exterior Room 11 D Door Frame Metal Intact 0.5 Negative153 Interior Room 11 D Door Wood Intact 0.2 Negative154 Interior Room 11 D Door Frame Metal Intact 0.5 Negative155 Interior Room 11 A Wall Plaster Intact 0.0 Negative156 Interior Room 11 B Wall Plaster Intact 0.1 Negative157 Interior Room 11 C Wall Plaster Intact 0.2 Negative158 Interior Room 11 D Wall Plaster Intact 0.1 Negative159 Interior Room 11 Ceiling Plaster Intact 0.1 Negative160 Exterior Stairway B Door Wood Intact 0.1 Negative161 Exterior Stairway B Door Frame Metal Intact 0.5 Negative162 Interior Stairway B Door Wood Intact 0.0 Negative163 Interior Stairway B Door Frame Metal Intact 0.4 Negative164 Interior Stairway A Wall Brick Intact 0.2 Negative165 Interior Stairway B Wall Gypsum Intact 0.1 Negative166 Interior Stairway C Wall Gypsum Intact 0.2 Negative167 Interior Stairway D Wall Gypsum Intact 0.0 Negative168 Interior Stairway A Wall Concrete Intact 0.0 Negative169 Interior Stairway B Wall Concrete Intact 0.0 Negative170 Interior Stairway C Wall Concrete Intact 0.1 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

6 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 22: LEAD-BASED PAINT INSPECTION REPORT

171 Interior Stairway D Wall Concrete Intact 0.1 Negative172 Interior Stairway Baseboard Wood Intact 0.1 Negative173 Interior Stairway Ceiling Gypsum Intact 0.1 Negative174 Interior Stairway Handrail Metal Intact 0.0 Negative175 Interior Stairway Railing Metal Intact 0.2 Negative176 Interior Stairway Stringer Metal Intact 0.2 Negative177 Exterior Room 12 D Door Wood Intact 0.0 Negative178 Exterior Room 12 D Door Frame Metal Intact 0.1 Negative179 Interior Room 12 D Door Wood Intact 0.0 Negative180 Interior Room 12 D Door Frame Metal Intact 0.1 Negative181 Interior Room 12 A Wall Brick Intact 0.0 Negative182 Interior Room 12 B Wall Gypsum Intact 0.1 Negative183 Interior Room 12 C Wall Gypsum Intact 0.2 Negative184 Interior Room 12 D Wall Gypsum Intact 0.1 Negative185 Interior Room 12 Ceiling Gypsum Intact 0.2 Negative186 Interior Room 12 C Electrical Panel Metal Intact 0.0 Negative187 Interior Room 13 C Door Wood Intact 0.0 Negative188 Interior Room 13 C Door Frame Metal Intact 0.1 Negative189 Interior Room 13 D Cabinet Frame Wood Intact 0.0 Negative190 Interior Room 13 D Cabinet Door Wood Intact 0.2 Negative191 Interior Room 13 D Cabinet Shelf Wood Intact 0.1 Negative192 Interior Room 13 A Wall Gypsum Intact 0.0 Negative193 Interior Room 13 B Wall Gypsum Intact 0.2 Negative194 Interior Room 13 C Wall Gypsum Intact 0.1 Negative195 Interior Room 13 D Wall Gypsum Intact 0.2 Negative196 Interior Room 13 Heater Vent Metal Intact 0.0 Negative197 Interior Room 13 Column Concrete Intact 0.2 Negative198 Interior Room 13 Beam Metal Intact 0.0 Negative199 Interior Restroom 2 A Door Wood Intact 0.0 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

7 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 23: LEAD-BASED PAINT INSPECTION REPORT

200 Interior Restroom 2 A Door Frame Wood Intact 0.1 Negative201 Interior Restroom 2 A Wall Gypsum Intact 0.0 Negative202 Interior Restroom 2 B Wall Gypsum Intact 0.1 Negative203 Interior Restroom 2 C Wall Gypsum Intact 0.1 Negative204 Interior Restroom 2 D Wall Gypsum Intact 0.2 Negative205 Exterior Room 14 C Door Metal Intact 0.0 Negative206 Exterior Room 14 C Door Frame Metal Intact 0.0 Negative207 Interior Room 14 C Door Metal Intact 0.1 Negative208 Interior Room 14 C Door Frame Metal Intact 0.0 Negative209 Interior Room 14 B Door Wood DETERIORATED 0.0 Negative210 Interior Room 14 B Door Frame Metal Intact 0.1 Negative211 Interior Room 14 A Wall Concrete Intact 0.0 Negative212 Interior Room 14 B Wall Concrete Intact 0.2 Negative213 Interior Room 14 C Wall Concrete Intact 0.1 Negative214 Interior Room 14 D Wall Concrete Intact 0.1 Negative215 Interior Room 14 B Wall Plaster Intact 0.0 Negative216 Interior Room 14 C Wall Plaster Intact 0.2 Negative217 Interior Room 14 Ceiling Concrete Intact 0.0 Negative218 Interior Room 14 A Electrical Panel Metal Intact 0.0 Negative219 Interior Room 15 D Door Wood Intact 0.0 Negative220 Interior Room 15 D Door Frame Metal Intact 0.1 Negative221 Interior Room 15 A Wall Plaster Intact 0.0 Negative222 Interior Room 15 B Wall Concrete Intact 0.2 Negative223 Interior Room 15 C Wall Concrete Intact 0.1 Negative224 Interior Room 15 D Wall Plaster Intact 0.1 Negative225 Interior Room 15 Ceiling Concrete Intact 0.2 Negative226 Interior Room 16 C Door Wood Intact 0.0 Negative227 Interior Room 16 C Door Frame Metal DETERIORATED 0.1 Negative228 Interior Room 16 B Cabinet Frame Wood Intact 0.1 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

8 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 24: LEAD-BASED PAINT INSPECTION REPORT

229 Interior Room 16 B Cabinet Door Wood Intact 0.2 Negative230 Interior Room 16 B Cabinet Shelf Wood Intact 0.1 Negative231 Interior Room 16 A Wall Gypsum Intact 0.0 Negative232 Interior Room 16 B Wall Gypsum Intact 0.1 Negative233 Interior Room 16 C Wall Gypsum Intact 0.2 Negative234 Interior Room 16 D Wall Gypsum Intact 0.1 Negative235 Interior Room 17 C Door Wood Intact 0.0 Negative236 Interior Room 17 C Door Frame Metal Intact 0.1 Negative237 Interior Room 17 A Wall Gypsum Intact 0.0 Negative238 Interior Room 17 B Wall Gypsum Intact 0.2 Negative239 Interior Room 17 C Wall Gypsum Intact 0.2 Negative240 Interior Room 17 D Wall Gypsum Intact 0.1 Negative241 Interior Room 17 Heater Vent Metal Intact 0.0 Negative242 Interior Room 18 C Door Wood Intact 0.0 Negative243 Interior Room 18 C Door Frame Metal Intact 0.1 Negative244 Interior Room 18 A Wall Gypsum Intact 0.1 Negative245 Interior Room 18 B Wall Gypsum Intact 0.2 Negative246 Interior Room 18 C Wall Gypsum Intact 0.2 Negative247 Interior Room 18 D Wall Gypsum Intact 0.1 Negative

Perimeter248 Exterior East Side A Window Frame Metal Intact 0.0 Negative FixedPerimeter249 Exterior East Side A Window Frame Metal Intact 0.0 Negative FixedPerimeter250 Exterior East Side A Window Frame Metal Intact 0.1 Negative FixedPerimeter251 Exterior East Side A Wall Brick Intact 0.0 NegativePerimeter252 Exterior East Side A Wall Brick Intact 0.2 NegativePerimeter253 Exterior East Side A Wall Brick Intact 0.1 NegativePerimeter254 Exterior East Side A Wall Brick Intact 0.1 NegativePerimeter255 Exterior East Side A Fascia Wood DETERIORATED 0.2 NegativePerimeter256 Exterior East Side A Fascia Wood DETERIORATED 0.4 NegativePerimeter257 Exterior East Side A Beam Wood Intact 0.0 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

9 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 25: LEAD-BASED PAINT INSPECTION REPORT

Perimeter258 Exterior East Side A Ceiling Stucco Intact 0.1 NegativePerimeter259 Exterior East Side A Gutter Metal DETERIORATED 0.0 NegativePerimeter260 Exterior East Side A Downspout Metal DETERIORATED 0.1 NegativePerimeter261 Exterior South Side B Door Wood Intact 0.3 NegativePerimeter262 Exterior South Side B Door Frame Metal Intact 0.5 NegativePerimeter263 Exterior South Side B Window Frame Metal Intact 0.0 Negative FixedPerimeter264 Exterior South Side B Window Frame Metal Intact 0.1 Negative FixedPerimeter265 Exterior South Side B Window Frame Metal Intact 0.1 Negative FixedPerimeter266 Exterior South Side B Window Frame Metal Intact 0.0 Negative FixedPerimeter267 Exterior South Side B Window Frame Metal Intact 0.2 Negative FixedPerimeter268 Exterior South Side B Window Frame Metal Intact 0.0 Negative FixedPerimeter269 Exterior South Side B Wall Brick Intact 0.0 NegativePerimeter270 Exterior South Side B Wall Brick Intact 0.1 NegativePerimeter271 Exterior South Side B Wall Brick Intact 0.2 NegativePerimeter272 Exterior South Side B Wall Stucco Intact 0.2 NegativePerimeter273 Exterior South Side B Fascia Wood DETERIORATED 0.3 NegativePerimeter274 Exterior South Side B Fascia Wood DETERIORATED 0.4 NegativePerimeter275 Exterior South Side B Column Brick Intact 0.0 NegativePerimeter276 Exterior South Side B Beam Wood Intact 0.1 NegativePerimeter277 Exterior South Side B Ceiling Stucco Intact 0.5 NegativePerimeter278 Exterior South Side B Column Metal Intact 0.3 NegativePerimeter279 Exterior South Side B Beam Wood Intact 0.3 NegativePerimeter280 Exterior South Side B Ceiling Stucco Intact 0.2 NegativePerimeter281 Exterior South Side B Gutter Metal DETERIORATED 0.2 NegativePerimeter282 Exterior South Side B Downspout Metal DETERIORATED 0.3 NegativePerimeter283 Exterior South Side B Vent Metal Intact 0.0 NegativePerimeter284 Exterior South Side B Floor Tile Intact 0.3 NegativePerimeter285 Exterior South Side B Trim Metal Intact 0.1 Negative Bike RackPerimeter286 Exterior South Side B Ramp Metal Intact 0.1 Negative

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

10 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 26: LEAD-BASED PAINT INSPECTION REPORT

Perimeter287 Exterior West Side C Door Wood Intact 0.5 NegativePerimeter288 Exterior West Side C Door Frame Metal Intact 0.3 NegativePerimeter289 Exterior West Side C Wall Stucco Intact 0.5 NegativePerimeter290 Exterior West Side C Wall Stucco Intact 0.4 NegativePerimeter291 Exterior West Side C Wall Brick Intact 0.0 NegativePerimeter292 Exterior West Side C Wall Brick Intact 0.2 NegativePerimeter293 Exterior West Side C Bollard Metal Intact 0.2 NegativePerimeter294 Exterior West Side C Bollard Metal DETERIORATED 0.3 NegativePerimeter295 Exterior West Side C Bollard Metal DETERIORATED 0.3 NegativePerimeter296 Exterior West Side C Parking Stripe Asphalt DETERIORATED 0.2 Negative WhitePerimeter297 Exterior West Side C Parking Stripe Asphalt DETERIORATED 0.2 Negative BluePerimeter298 Exterior West Side C Curb Concrete Intact 0.1 Negative RedPerimeter299 Exterior North Side D Wall Brick Intact 0.2 NegativePerimeter300 Exterior North Side D Wall Brick Intact 0.2 NegativePerimeter301 Exterior North Side D Wall Brick Intact 0.0 NegativePerimeter302 Exterior North Side D Wall Brick Intact 0.2 NegativePerimeter303 Exterior North Side D Downspout Metal DETERIORATED 0.2 NegativePerimeter304 Exterior North Side D Downspout Metal DETERIORATED 0.1 NegativePerimeter305 Exterior North Side D Vent Metal Intact 0.0 NegativePerimeter306 Exterior North Side D Awning Metal Intact 0.1 Negative At DoorPerimeter307 Exterior North Side D Awning Metal Intact 0.0 Negative At DoorCalibration308 Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.0 NegativeCalibration309 Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.0 NegativeCalibration310 Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.1 NegativeCalibration311 Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVECalibration312 Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.2 POSITIVECalibration313 Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.2 POSITIVE

FIELD DATA REPORTTemple City LibraryProject Name:

Address:5939 Golden West AvenueTemple City,CA 91780

Project Number:3014044Protocol:LA County

Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments

11 of 11 6/5/2019 11:41:49 AMBarr & Clark Environmental (714) 894-5700

L.A. County DHS action level for lead paint is 0.7 mg/cm2.Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2.

Page 27: LEAD-BASED PAINT INSPECTION REPORT

APPENDIX

B CDPH 8552

INSPECTOR’S CERTIFICATES

INSURANCE CERTIFICATE

Page 28: LEAD-BASED PAINT INSPECTION REPORT

State of California-Health and Human Services Agency California Department of Public Health

LEAD HAZARD EVALUATION REPORT Section 1-Date of Lead Hazard Evaluation 06-04-2019 Section 2-Type of Lead Hazard Evaluation (Check one box only)

Lead inspection Risk assessment Clearance inspection Other (specify)

Section 3-Structure Where Lead Hazard Evaluation Was Conducted Address (number, street, apartment (if applicable)

5939 Golden West Avenue

City

Temple City

County LA

ZIP code

91780

Construction date (year) of structure 1960

Type of structure (check one box only) Children Living in Structure?

Multi-unit building School or Daycare Yes No Single Family Dwelling Other (Library) Don’t Know

Section 4-Owner of Structure (If business/agency, list contact person) Name

Erik Mar

Telephone number

(310) 508-9390

Address [number, street, apartment (if applicable)]

5939 Golden West Avenue

City

Temple City

State CA

ZIP code

91780

Section 5-Results of Lead Hazard Evaluation (Check all that apply) No lead-based paint detected Intact Lead-based paint detected Deteriorated Lead-based paint detected No lead hazards detected Lead Contaminated Dust Found Lead Contaminated Soil Found Other (specify)

Section 6-Individual Conducting Lead Hazard Evaluation

Name

Jeremy Nguyen

Telephone number

714-894-5700

Address (number, street, apartment (if applicable) 16531 Bolsa Chica, Suite 205

City Huntington Beach

State CA

ZIP code 92649

CDPH certification number

25548

Signature

Date

6/10/2019

Name and CDPH certification number of any other individuals conducting sampling or testing (if applicable)

Section 7-Attachments

A. A foundation diagram or sketch of the structure indicating the specific locations of each lead hazard or presence of lead-based paint; B. Each testing method, device, and sampling procedure used;

C. All data collected, including quality control data, laboratory results, including laboratory name, address, and phone number. First copy and attachments retained by inspector Second copy and attachments retained by owner Third copy only (no attachments) mailed to:

California Department of Public Health Childhood Lead Poisoning Prevention Branch Reports 850 Maria Bay Parkway, Building P, Third Floor Richmond, CA 94804-6403 Fax (510) 620-5656 CDPH 8552 (6/07)

Page 29: LEAD-BASED PAINT INSPECTION REPORT
Page 30: LEAD-BASED PAINT INSPECTION REPORT
Page 31: LEAD-BASED PAINT INSPECTION REPORT
Page 32: LEAD-BASED PAINT INSPECTION REPORT
Page 33: LEAD-BASED PAINT INSPECTION REPORT

APPENDIX

C MAP(S)

Page 34: LEAD-BASED PAINT INSPECTION REPORT

ROOM 1 ROOM 6

ROO

M 7

ROOM 8

ROOM 9RESTROOM 1

ROOM 10

ROOM 2

ROOM 4

CL

ROOM 3

MEN

'SRE

STRO

OM

ROOM

5RO

OM

11

WO

MEN

'SRE

STRO

OM

ROOM 12

ROOM 18 ROOM 17 ROOM 16

RESTROOM 2

ROOM 13

ROOM 15

ROOM 14

STAIRWAY

STAIRWAY

FX

FX

FX

FX

FX

FX

BASEMENT

C

A

DB

Temple City Library5939 Golden West Avenue

Temple City, CAProject# 3014044

Window Key:FX = Fixed

Page 35: LEAD-BASED PAINT INSPECTION REPORT

TEMPLE CITY LIBRARY Instructions to Bidders

Bid Number LACDA 19--062 00100-26

ATTACHMENT E

LIMITED ASBESTOS INSPECTION REPORT

Page 36: LEAD-BASED PAINT INSPECTION REPORT

BARR & CLARK Independent Environmental Testing

Asbestos • Lead • Mold • Phase I

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

ASBESTOS INSPECTION REPORT

OF

TEMPLE CITY LIBRARY

5939 GOLDEN WEST AVENUE

TEMPLE CITY, CA 91780

PROJECT NO. 3014044

JUNE 11, 2019

Prepared For:

emar Studio

3341 Helms Avenue

Culver City, CA 90232

Inspected & Prepared By: Reviewed By:

Keith Piner Matt Crochet

State of California State of California

Certified Asbestos Consultant Certified Asbestos Consultant

Page 37: LEAD-BASED PAINT INSPECTION REPORT

Asbestos Inspection Report

Temple City Library

5939 Golden West Avenue Project No. 3014044

Page 2

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

TABLE OF CONTENTS

DESCRIPTION PAGE NO.

1.0 INTRODUCTION .......................................................................................................... 3

2.0 SCOPE OF WORK ......................................................................................................... 3

3.0 PROPERTY DESCRIPTION ......................................................................................... 3

4.0 INSPECTOR’S QUALIFICATIONS ............................................................................. 3

5.0 SAMPLING PROTOCOL / SAMPLE ANALYSIS ...................................................... 3

6.0 SUMMARY OF RESULTS ........................................................................................... 4

7.0 RECOMMENDATIONS ................................................................................................ 5

8.0 INSPECTION LIMITATIONS ...................................................................................... 5

APPENDICES

APPENDIX A LABORATORY RESULTS

APPENDIX B INSPECTOR’S CERTIFICATE(S)

APPENDIX C INSURANCE CERTIFICATE

APPENDIX D MAP(S)

Page 38: LEAD-BASED PAINT INSPECTION REPORT

Asbestos Inspection Report

Temple City Library

5939 Golden West Avenue Project No. 3014044

Page 3

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

ASBESTOS INSPECTION REPORT

1.0 INTRODUCTION

This report presents the results of Barr & Clark’s asbestos inspection of the Temple City Library

located at 5939 Golden West Avenue, Temple City, California (Subject Property). This document

is prepared for the sole use of emar Studio, and any regulatory agencies that are directly involved

in this project. No other party should rely on the information contained herein without prior

written consent of emar Studio. The scope of services, inspection methodology, and results are

presented below.

2.0 SCOPE OF WORK

The purpose of this inspection is to identify and assess certain accessible Asbestos Containing

Construction Materials (ACCM) at the subject property.

On June 04, 2019, Barr & Clark performed an inspection for asbestos at the subject property in

Temple City, California. Physical bulk samples were collected of suspect materials from

representative locations and submitted to an independent laboratory for analysis. If asbestos was

detected at any concentration within a sample of a construction material, it was concluded that

the material contains asbestos. Suspect materials were also visually inspected to assess their

condition.

3.0 PROPERTY DESCRIPTION

The subject property is a library that was built circa 1960. It is a one-story building that is

constructed over a basement. The exterior walls are covered with stucco and brick and all of the

windows are fixed types.

4.0 INSPECTOR’S QUALIFICATIONS

Keith Piner of Barr & Clark performed the inspection at the site. Personnel certificate(s) have

been provided in Appendix B.

5.0 SAMPLING PROTOCOL / SAMPLE ANALYSIS

Sampling Protocol: Sampling was patterned after the Asbestos School Hazard Emergency

Response Act (40 CFR 763 Subpart E) as mandated by Cal/OSHA (Title 8 Section 1529) and

South Coast Air Quality Management District (Rule 1403).

Sample Analysis: Physical bulk samples were collected from this property and analyzed for

asbestos content by an independent environmental laboratory which is accredited by the National

Voluntary Laboratory Accreditation Program (Lab Code 200358-0). The method of analysis was

Polarized Light Microscopy (EPA 600/M4-82-020). Additional laboratory information can be

found on the last page of the laboratory results (Appendix A).

Page 39: LEAD-BASED PAINT INSPECTION REPORT

Asbestos Inspection Report

Temple City Library

5939 Golden West Avenue Project No. 3014044

Page 4

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

6.0 SUMMARY OF RESULTS

Asbestos Containing Construction Materials: Asbestos was detected in samples of several

construction materials. The following summary identifies these materials, their location within

the property, the condition in which they were observed at the time of inspection, approximate

quantity of material and percentage of asbestos contained in the material as reported by

laboratory analysis.

Material Sample # Location Condition Quantity* % Asbestos

Flooring 20 – 22

Room 2 Closet, Room 11

and All Like Flooring

Throughout

Good 150 S.F. 2%

Flooring Mastic 20 – 22

Room 2 Closet, Room 11

and All Like Flooring

Mastic Throughout

Good 150 S.F. 3%

Flooring

(Bottom Layer) 26 – 28

Room 3, Room 4, Room 5,

Room 10 and All Like

Flooring Throughout

Good 185 S.F. 2%

Flooring Mastic 26 – 28

Room 3, Room 4, Room 5,

Room 10 and All Like

Flooring Mastic Throughout

Good 185 S.F. 4%

Cove Base

Mastic 29

Room 2 and All Cove Base

Mastic Throughout Building Good 190 S.F. 2%

Thermal Systems

Insulation (TSI) 36 Attic Space Damaged 350 L.F. 50%

Asbestos Cement

Pipe(s) Visual Attic & Roof Good 10 L.F. Assumed

Flooring 50 Restroom 2 and All Like

Flooring Throughout Good 15 S.F. 35%

*NOTE: All quantification estimates are approximate and based on information and materials

that were accessible at the time of inspection. The chosen contractor is solely responsible for

verifying all final ACCM quantities for bidding, abatement, and disposal purposes.

**NOTE: The ductwork under the building was not accessible and therefore not inspected or

sampled. Any suspect ductwork under the building must be assumed positive until properly

identified.

Page 40: LEAD-BASED PAINT INSPECTION REPORT

Asbestos Inspection Report

Temple City Library

5939 Golden West Avenue Project No. 3014044

Page 5

1 6 5 3 1 B o l s a C h i c a , S u i t e 2 0 5 • H u n t i n g t o n B e a c h , C A 9 2 6 4 9 • 7 1 4 . 8 9 4 . 5 7 0 0

w w w . b a r r a n d c l a r k . c o m

7.0 RECOMMENDATIONS

The analysis and recommendations submitted in this survey are based in part on the data

obtained from specific and discrete sampling locations. However, the nature and extent of

variations between the sampling locations may not become evident until renovation or

demolition procedures commence. If potential variations (i.e. different building materials) are

identified during renovation or demolition activities, it will be necessary to conduct additional

bulk sampling.

ACCM in Damaged or Significantly Damaged Condition: These materials present the

greatest risk for asbestos exposure. It is recommended that all damaged and/or significantly

damaged asbestos containing construction materials be removed following SCAQMD Rule

1403 Procedure 5. An asbestos abatement contractor registered with the Division of

Occupational Safety and Health must perform any work that disturbs these materials.

ACCM in Good Condition: No action is recommended for these materials. Asbestos

containing materials that are maintained in good condition present minimal risk for asbestos

exposure.

Note: If renovation or demolition activities are to affect these materials, an asbestos abatement

contractor registered with the Division of Occupational Safety and Health should be contracted

to perform all portions of the work affecting these materials.

8.0 INSPECTION LIMITATIONS

This inspection was planned, developed, and implemented based on Barr & Clark’s previous

experience in performing asbestos inspections. Barr & Clark utilized state-of-the-art-practices

and techniques in accordance with regulatory standards while performing this inspection. Barr &

Clark’s evaluation of the relative risk of exposure to asbestos identified during this inspection is

based on conditions observed at the time of the inspection. Barr & Clark cannot be responsible

for changing conditions that may alter the relative exposure risk or for future changes in accepted

methodology.

This inspection did not evaluate hidden, buried or unseen building or other materials. When

future renovation or demolition activities are undertaken, Barr & Clark should be contacted if

such are encountered for further evaluation. Any materials that were not sampled during the

inspection must be presumed to contain asbestos until proven otherwise. Access and inspection

of attics or crawl spaces could be limited due to visibility, obstructions, health and safety hazards

or structural issues. All undocumented materials should be presumed to contain asbestos until

sampled and analyzed.

Enclosed are the actual test results and all relevant certifications and licenses.

Page 41: LEAD-BASED PAINT INSPECTION REPORT

APPENDIX

A (LABORATORY RESULTS)

Page 42: LEAD-BASED PAINT INSPECTION REPORT

EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043

Tel/Fax: (716) 651-0030 / (716) 651-0394

http://www.EMSL.com / [email protected]

141902485EMSL Order:

Customer ID: 32BACA26

Customer PO: 3014044

Project ID:

Attention: Phone:Barr & Clark (714) 894-5700

Fax:Barr & Clark, Inc.

Received Date:16531 Bolsa Chica Street 06/06/2019 11:23 AM

Analysis Date:Suite 205 06/06/2019

Collected Date:Huntington Beach, CA 92649 06/04/2019

Project: 3014044 / Temple City Library / 5939 Golden West Avenue, Temple City CA 91780

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1-Skim Coat

141902485-0001

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Ext. Walls - Stucco

1-Base Coat

141902485-0001A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Ext. Walls - Stucco

2-Skim Coat

141902485-0002

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Ext. Walls - Stucco

2-Base Coat

141902485-0002A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Ext. Walls - Stucco

3-Skim Coat

141902485-0003

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Ext. Walls - Stucco

3-Base Coat

141902485-0003A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Ext. Walls - Stucco

4

141902485-0004

None DetectedNon-fibrous (Other)85%Cellulose15%Black

Fibrous

Homogeneous

Roof - Tar and Gravel

5

141902485-0005

None DetectedNon-fibrous (Other)90%Cellulose10%Black

Fibrous

Homogeneous

Roof - Tar and Gravel

6

141902485-0006

None DetectedNon-fibrous (Other)90%Cellulose10%Black

Fibrous

Homogeneous

Roof - Tar and Gravel

7

141902485-0007

None DetectedNon-fibrous (Other)92%Cellulose8%Gray/Black

Fibrous

Homogeneous

Roof at Penetrations

& Patches - Roofing

Mastic

8

141902485-0008

None DetectedNon-fibrous (Other)95%Cellulose5%Black

Fibrous

Homogeneous

Roof at Penetrations

& Patches - Roofing

Mastic

9

141902485-0009

None DetectedNon-fibrous (Other)95%Cellulose5%Black

Fibrous

Homogeneous

Roof at Penetrations

& Patches - Roofing

Mastic

10

141902485-0010

None DetectedNon-fibrous (Other)95%Cellulose5%White/Black

Fibrous

Homogeneous

Roof - Rolled Roofing

11

141902485-0011

None DetectedNon-fibrous (Other)95%Cellulose5%White/Black

Fibrous

Homogeneous

Roof - Rolled Roofing

12

141902485-0012

None DetectedNon-fibrous (Other)95%Cellulose5%White/Black

Fibrous

Homogeneous

Roof - Rolled Roofing

13

141902485-0013

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 2 Closet -

Plaster

Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance

Page 1 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM

Page 43: LEAD-BASED PAINT INSPECTION REPORT

EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043

Tel/Fax: (716) 651-0030 / (716) 651-0394

http://www.EMSL.com / [email protected]

141902485EMSL Order:

Customer ID: 32BACA26

Customer PO: 3014044

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

14

141902485-0014

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 3 - Plaster

15

141902485-0015

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Womens Restroom -

Plaster

16

141902485-0016

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 6 - Plaster

17

141902485-0017

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 7 - Plaster

18

141902485-0018

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 8 - Plaster

19

141902485-0019

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 9 - Plaster

20-Floor Tile

141902485-0020

2% ChrysotileNon-fibrous (Other)98%White

Fibrous

Homogeneous

Room 2 Closet - 9x9

VFT

20-Mastic

141902485-0020A

3% ChrysotileNon-fibrous (Other)97%Black

Fibrous

Homogeneous

Room 2 Closet - 9x9

VFT

21-Floor Tile

141902485-0021

Positive Stop (Not Analyzed)Room 2 Closet - 9x9

VFT

21-Mastic

141902485-0021A

Positive Stop (Not Analyzed)Room 2 Closet - 9x9

VFT

22-Floor Tile

141902485-0022

Positive Stop (Not Analyzed)Room 11 - 9x9 VFT

22-Mastic

141902485-0022A

Positive Stop (Not Analyzed)Room 11 - 9x9 VFT

23

141902485-0023

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

Room 3 Top Layer -

12x12 VFT

24

141902485-0024

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

Room 4 Top Layer -

12x12 VFT

25

141902485-0025

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

Room 10 Top Layer -

12x12 VFT

26-Floor Tile

141902485-0026

2% ChrysotileNon-fibrous (Other)98%White

Fibrous

Homogeneous

Room 3 Bottom Layer

- Flooring

26-Mastic

141902485-0026A

4% ChrysotileNon-fibrous (Other)96%Black

Fibrous

Homogeneous

Room 3 Bottom Layer

- Flooring

27-Floor Tile

141902485-0027

Positive Stop (Not Analyzed)Room 2 Bottom Layer

- Flooring

27-Mastic

141902485-0027A

Positive Stop (Not Analyzed)Room 2 Bottom Layer

- Flooring

Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance

Page 2 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM

Page 44: LEAD-BASED PAINT INSPECTION REPORT

EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043

Tel/Fax: (716) 651-0030 / (716) 651-0394

http://www.EMSL.com / [email protected]

141902485EMSL Order:

Customer ID: 32BACA26

Customer PO: 3014044

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

28-Floor Tile

141902485-0028

Positive Stop (Not Analyzed)Room 10 Bottom

Layer - Flooring

28-Mastic

141902485-0028A

Positive Stop (Not Analyzed)Room 10 Bottom

Layer - Flooring

29-Cove Base

141902485-0029

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

Room 2 Closet -

Covebase & Mastic

29-Mastic

141902485-0029A

2% ChrysotileNon-fibrous (Other)98%Brown

Fibrous

Homogeneous

Room 2 Closet -

Covebase & Mastic

30-Drywall

141902485-0030

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Room 9 - DW/JC

30-Joint Compound

141902485-0030A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 9 - DW/JC

31-Drywall

141902485-0031

None DetectedNon-fibrous (Other)100%Gray/White

Non-Fibrous

Homogeneous

Room 10 - DW/JC

31-Joint Compound

141902485-0031A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 10 - DW/JC

32-Drywall

141902485-0032

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Restroom 1 - DW/JC

32-Joint Compound

141902485-0032A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Restroom 1 - DW/JC

33

141902485-0033

None DetectedNon-fibrous (Other)5%Cellulose

Glass

45%

50%

Gray/White

Fibrous

Homogeneous

Room 1 - 1x1 Ceiling

Tile

34

141902485-0034

None DetectedNon-fibrous (Other)10%Cellulose

Glass

40%

50%

Gray/White

Fibrous

Homogeneous

Attic Space - 1x1

Ceiling Tile

35

141902485-0035

None DetectedNon-fibrous (Other)5%Cellulose

Glass

45%

50%

Gray/White

Fibrous

Homogeneous

Room 8 - 1x1 Ceiling

Tile

36

141902485-0036

50% ChrysotileNon-fibrous (Other)5%Cellulose45%Gray

Fibrous

Homogeneous

Attic Space - TSI

37

141902485-0037

None DetectedNon-fibrous (Other)90%Cellulose10%Gray

Fibrous

Homogeneous

Room 14 - Pipe

Insulation

38

141902485-0038

None DetectedNon-fibrous (Other)93%Cellulose7%Gray

Fibrous

Homogeneous

Room 15 - Pipe

Insulation

39-Drywall

141902485-0039

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Room 12 - DW/JC

39-Joint Compound

141902485-0039A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 12 - DW/JC

40-Drywall

141902485-0040

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Room 13 - DW/JC

Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance

Page 3 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM

Page 45: LEAD-BASED PAINT INSPECTION REPORT

EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043

Tel/Fax: (716) 651-0030 / (716) 651-0394

http://www.EMSL.com / [email protected]

141902485EMSL Order:

Customer ID: 32BACA26

Customer PO: 3014044

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

40-Joint Compound

141902485-0040A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 13 - DW/JC

41-Drywall

141902485-0041

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Room 16 - DW/JC

41-Joint Compound

141902485-0041A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 16 - DW/JC

42-Drywall

141902485-0042

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Room 17 - DW/JC

42-Joint Compound

141902485-0042A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 17 - DW/JC

43-Drywall

141902485-0043

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Room 18 - DW/JC

43-Joint Compound

141902485-0043A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Room 18 - DW/JC

44-Floor Tile

141902485-0044

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

Stairway - Flooring

44-Mastic

141902485-0044A

None DetectedNon-fibrous (Other)100%Gold

Non-Fibrous

Homogeneous

Stairway - Flooring

45-Floor Tile

141902485-0045

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Room 13 - Flooring

45-Mastic

141902485-0045A

None DetectedNon-fibrous (Other)100%Gold

Non-Fibrous

Homogeneous

Room 13 - Flooring

46-Floor Tile

141902485-0046

None DetectedNon-fibrous (Other)100%Red

Non-Fibrous

Homogeneous

Room 16 - Flooring

46-Mastic

141902485-0046A

None DetectedNon-fibrous (Other)100%Gold

Non-Fibrous

Homogeneous

Room 16 - Flooring

47

141902485-0047

None DetectedNon-fibrous (Other)40%Glass60%Gray

Fibrous

Homogeneous

Room 13 -

Fireproofing

48

141902485-0048

None DetectedNon-fibrous (Other)45%Glass55%Gray

Fibrous

Homogeneous

Room16 -

Fireproofing

49

141902485-0049

None DetectedNon-fibrous (Other)100%Gray

Fibrous

Homogeneous

Room 18 -

Fireproofing

50

141902485-0050

35% ChrysotileNon-fibrous (Other)65%Brown/Gray

Fibrous

Homogeneous

Restroom 2 - Flooring

Linoleum and mastic layers are inseparable.

Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance

Page 4 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM

Page 46: LEAD-BASED PAINT INSPECTION REPORT

EMSL Analytical, Inc.490 Rowley Road Depew, NY 14043

Tel/Fax: (716) 651-0030 / (716) 651-0394

http://www.EMSL.com / [email protected]

141902485EMSL Order:

Customer ID: 32BACA26

Customer PO: 3014044

Project ID:

Analyst(s)

Margo Burgio (63) Rhonda McGee, Laboratory Manager

or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim

Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without

written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All

samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of

the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Depew, NY NVLAP Lab Code 200056-0

Report amended: 06/07/2019 10:39:38 Replaces initial report from: 06/06/2019 14:11:50 Reason Code: Data Entry-Change to Appearance

Page 5 of 5ASB_PLM_0008_0001 - 1.78 Printed: 6/7/2019 10:40 AM

Page 47: LEAD-BASED PAINT INSPECTION REPORT

OrderID: 141902485

Page 1 Of 5

Page 48: LEAD-BASED PAINT INSPECTION REPORT

OrderID: 141902485

Page 2 Of 5

Page 49: LEAD-BASED PAINT INSPECTION REPORT

OrderID: 141902485

Page 3 Of 5

Page 50: LEAD-BASED PAINT INSPECTION REPORT

OrderID: 141902485

Page 4 Of 5

Page 51: LEAD-BASED PAINT INSPECTION REPORT

OrderID: 141902485

Page 5 Of 5