Upload
jeyaganthan-umapathy
View
16
Download
1
Embed Size (px)
Citation preview
CONFIDENTIAL 10/21/2016
1
KNOW ABOUT FANS & APPLICATIONS
Presented by U Jeyaganthan Cell:+91 9940085705U Jeyaganthan- Cell:+91 9940085705
U.JEYAGANTHAN
Introduction on centrifugal fans
INDEX
Basic principlesTypes of fansFan TerminologyFans application in the process sectorsRequirements for selecting a fanCustomers / OEM'sNeed of Retrofit
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
2
The purpose of a “fan” is to
PURPOSE OF FANS
move a mass of gas or air at
the desired velocity with an
appreciable rise in pressure
to overcome some kind of
resistance in flowresistance in flow(Centrifugal& Axial)
U.JEYAGANTHAN
Air or gas enters the impeller eye axially
CENTRIFUGAL FANS-BASIC PRINCIPLE
and leaves radial.
The pressure is developed due to the centrifugal force imparted on the gas trapped between the blades.
The partial vacuum creates further suction imparting continuous air / gas flow.
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
3
A) FORCED DRAUGHT FANS:
TYPES OF FANS
These fans collect air from atmosphereand deliver into the system. (Fan Inlet open/ Outlet connect to system)
Ex: Cooler fans in a Cement Plant
B) INDUCED DRAUGHT FANS
These fan Inlet and outlets normallyyconnect with systems. ID fan collect air/gas from one system and deliver intothe next system or Exhaust to air
Ex: Raw Mill ID & BH Fans
U.JEYAGANTHAN
FAN- BLADE PROFILES
Airfoil (AF) Eff:90%
Backward-curved (BC)
•Different types of fans characterized by
their blade type Backward curved (BC) Eff:85%
Backward-inclined (BI)Eff: 78%
Radial-tip (RT)Eff:70%
their blade type
•Different applications
require different
blade type
Forward-curved (FC)Eff: 65%
Radial blade (RB)Eff: 60%
yp
•Each type has different fan performance curves
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
4
FAN SELECTION INPUTS
Volumetric Flow
Static Pressure at Fan Inlet
Fan Selections
Static Pressure at Fan outlet
Operating & Design Temperatures
Nature of Application
Dust Concentration
Actual Density of Flue gas/ Air
Preferable fan speedPreferable fan speed
Frequency (Hz)
Drive Arrangement
Fan Arrangement
U.JEYAGANTHAN
FANS-TERMINOLOGY
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
5
FAN TERMINOLOGY
U.JEYAGANTHAN
FAN –AERODYNAMIC CHARACTERISTIC CURVE
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
6
1. Volume is directly proportional to fan speed
FAN LAWS- CHANGE IN SPEED
Q N2 2
2. Pressure is proportional to the
square of the velocity
Q N2
1
2
1=
T PT P
S PS P
V PV P
NN
2
1
2
1
2
1
2
1
2= = =
⎛⎝⎜
⎞⎠⎟
3. Power is the product of volume by energy
1 1 1 1
PP
NN
2
1
2
1
3=
⎛⎝⎜
⎞⎠⎟
U.JEYAGANTHAN
FAN LAWS- CHANGE IN IMPELLER DIAMETER
Changing the Impeller DiameterIf wheel velocity is constant a change in impeller diameter can simplify the affinityimpeller diameter can simplify the affinity laws to
Volume Capacityq1 / q2 = (d1 / d2)3 (1b)
Head or Pressuredp1 / dp2 = (d1 / d2)2 (2b)
U.JEYAGANTHAN
PowerP1 / P2 = (d1 / d2)5 (3b)
CONFIDENTIAL 10/21/2016
7
FAN APPLICATION IN CEMENT PROCESS PLANTS
U.JEYAGANTHAN
Raw mill:
FAN APPLICATION IN CEMENT PROCESS
Packing Plant:Small size fans & BlowersRaw mill:
ID & ESP/ BH Fans
Coal Mill:Booster & Recirculation Fans
Pre Heater:Kiln, Pyro & Calciner String FansKiln ESP Fan
Small size fans & Blowers
** WHRS (Waste Heat Recovery Boiler System)ID Fan
Cooler:Cooler FD & Cooler Vent / ESP Fans
Cement mill:Cement Mill ID & BH FansSeparator Fans
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
8
STEEL PROCESS FLOW CHART
U.JEYAGANTHAN
Sintering Plant (SP):
FANS APPLICATION IN STEEL PLANTS
Direct Reduced Iron (DRI): ID & FD Fans
Waste Gas FanCooling Air FanHot Air fan &Secondary Air FanCoke Oven Fans
Electric Arc Furnace (EAF):ID Fans
Mini Blast Furnace (MBF):High Pressure BlowersExhaust Fan
Pelletizing:gID/PA & SA Fans
Steel Melting System (SMS)ID Exhaust Fans
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
9
FANS APPLICATIONS IN POWER PLANTS- BOILER
U.JEYAGANTHAN
1. ID Fans
THERMAL POWER STATION- BOILER APPLICATION
2. FD Fans
3. PA Fans4. SA Fans
5. Seal Air Fans6 C b ti Ai F6. Combustion Air Fan
7. Blowers like
scanner Air fan etc.
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
10
REFORMER ID FAN
FAN APPLICATION IN REFINERIES
REFORMER ID FANCOMBUSTION AIR FANPRIMARY AIR FANSECONDARY AIR FAN FD FAN
U.JEYAGANTHAN
CRITICAL FAN PARTS - ROTOR
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
11
FABRICATION FAN PARTS - STATOR
U.JEYAGANTHAN
ErosionBuild up / Coating
Major Problems
FAN TROUBLE SHOOTING
Build up / CoatingLack of capacityUnbalance in Impeller.VibrationsBearing FailureLeakagesL b i iLubricationSurgingMisalignmentImproper layout systemUn stability in Process
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
12
IMPELLER WEAR PROBLEM DURING OPERATION
U.JEYAGANTHAN
IMPELLER WEAR PROBLEM DURING OPERATION
CorrosionFatguei
Build up & Vibrations
Lack of CapacityOver Consumption Extreme Temp Conditions Surging
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
13
HARD FACING METAL DEPOSED BY WELDING
Wear plates with hard facing materialsIMPELLER WEAR PLATES WITH HARD FACING
BLADE
CARBON STEEL PLATE
Hard facing material is never welded directly on the blades toavoid metallurgical problem.
This protection can be easily replaced without modifyingthe mechanical structure of the impeller.
Even airfoil blades can be protected
U.JEYAGANTHAN
Fan Retrofit ?????
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
14
Fans - Major power consumers
F b ffi i
OBJECTIVE:
Fans operate at best efficiency at original design point
Modernization / Up-gradation of plant changes system resistance
Hence fans operate less efficiently
Retrofit & upgrades (R&U) : provides solution
U.JEYAGANTHAN
System Resistance Change?
NEED FOR RETROFITTING
1. Retrofitting means upgrading the existing equipment to improve the efficiency and performance of the equipment. 2 Retrofitting is usually performed in large scale industries such as Cement2. Retrofitting is usually performed in large scale industries such as Cement Industry, Power plant industry where a complete new installation consumes huge amount of time and money.3. The basic need for retrofitting in industrial fans is to improve the performance of the existing fan.
Need for Retrofitting•Optimization of existing fans•Retrofitting of industrial fan involves adding or replacing a component to the•Retrofitting of industrial fan involves adding or replacing a component to the existing fan system in order to achieve increased performance.•Coming to the retrofitting of industrial fans, it will be something like change in system resistance either to increase or decrease depending on need. Industrial fans start to decrease its performance after some period of time. With retrofitting one can optimize the existing fan.
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
15
Retrofitting is a better alternative to optimize fan performance. It also has many advantages and can be easily performed with less investment and Why
R t fit ?
FAN RETROFIT / ENHANCEMENT OPTIONS
y pin less time period.
A change to variable speed drive
Increasing the fan Capacity
Reducing the fan power consumption
Replacing the impeller (..in an existing casing
Retrofit ?
p g p ( g gwith another design impeller)
Adding erosion or corrosion protection
Improving inlet / discharge flow conditions( System Effects)
U.JEYAGANTHAN
RETROFIT –ALTERNATIVE SOLUTION
Retrofit uses maximum availability of existing equipment and which is a economic alternative than a complete new installation.
R t fit bi th d t f i ti i t dRetrofit combines the advantages of existing equipment and new equipment which is a cost saving option.
Retrofitting involves simple assembly which does not require a skilled labour who is expensive than a regular manpower.
If we take the case of installing a complete new system in the plant, we have to shut down the entire system for a longer period of time.
If we perform retrofitting, as it involves installation of parts, it will consume less time for installation and decreases the shut down period. This regulates the overall loss to the plant.
U.JEYAGANTHAN
CONFIDENTIAL 10/21/2016
16
FAN RETROFIT – KEY WAYS
When the flow of a fan is reduced, the rotor and inlet are replaced in orderto enhance the flow and pressure for the same input power of an industrial fan.
Industrial fan also consists of small parts which are to be changed to obtain anIndustrial fan also consists of small parts which are to be changed to obtain an increased efficiency. The parts which are involved are casing of fans, inlet boxes, dampers and silencers etc.
Bearings in fan are one of the most important parts; the life period of a fan depends on the working condition of a bearing. Changing bearings will ensure more life and lesser maintenance for an Industrial fan.
Industrial fan consists of rotating parts, which cause wear of the material. By ti i t t t i l t th l t f f ill lt icoating wear resistant material on rotor or any other plants of fan will result in
good wear life.Industrial fan also produces a lot of noise; the level of noise can be minimized
by retrofitting silencers or dampers to the fan.
U.JEYAGANTHAN
RETROFIT PERFORMANCE CASE STUDIES
CASE STUDY No. : 01 POWER SAVING & CAPACITY ENHANCEMENT
C t O i t F t HF4S TSR 360 3TS8Customer : Orissa cements Plant : Orissa , Rajgangpur. (3000 TPD)
Fan type : HF4S TSR 360 3TS8 Application : Pre heater fan
New Fan in the existing foundation and System replacing HUMBOLDT fan. Sl.No Parameters Unit Old Fan New Fan Change in %
Design Design 1 Inlet Flow m3/hr 396000.0 410000.0 3.5 2 Net Static Pressure mmwg 841.0 1000.0 18.9 3 Speed rpm 980 930 -
U.JEYAGANTHAN
4 Power consumption at fan shaft kW 1158 1267 9.4 5 Fan Efficiency % 78.3 88.1 12.5
Summary
A new fan is fitted in the existing foundation to enhance the capacity as well as efficiency.
CONFIDENTIAL 10/21/2016
17
RETROFIT PERFORMANCE CASE STUDIES
Case study : 02Power saving & Capacity Enhancement
C t M/ G i I d t i Ltd R i E i ti F T HF5S TDR 315 3TD8A
Old Fan : Flakt New Fan- F18 TDR 368 3TD8A
Design Design1 Volume m3/hr 640000 700000 9%2 Net static pressure mmwg 1590 1480
Plant: Raipur, Chattisgarh Application: Raw Mill FanRetrofit Impeller,Hub in existing condition for power savings & capacity enhancement purpose
S no
Parameters Unit Capacity increase
Customer: M/sGrasim Industries Ltd,Raipur Existing Fan Type : HF5S TDR 315 3TD8A
2 Net static pressure mmwg 1590 14803 Speed rpm 930 9094 Fan shaft power Kw 3432 32725 Fan Efficiency % 80.75 86.2
Power savings Kw 160.5 202Note : Scope of Supply
Actual Power savings 202 KW. Performance proved at site Impeller, Hub &cones only
U.JEYAGANTHAN
PLEASE CONTACT:
U.JEYAGANTHAN