14
Status January 2019. All mentioned trademarks or brands are property of the corresponding owner. Subject to error and technical changes.V21 KLARI-PROBES Features KLARI-PROBES are the convenient measuring units for low voltage Klaric modules up to 80V. • For current measurements the PROBES are equipped with low resistive accuracy resistors, for voltage measurements with voltage dividers. Temperature measurements are executed with PT1000 resistance thermometers which are also available in acid resistant version. • All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read out of the PROBE and transmitted to the module. • The adjustment values are considered for the measurement result calculation. This implicates a very high degree of accuracy. • Because the shunts only have marginal temperature drift, temperature compensation is not needed. • A factory calibration is included in scope of delivery. On request we are pleased to offer a DAkkS calibration. Versions LI-PROBES: These PROBES are used to measure currents in range of 0,25µA…150A (peak current). The user has to take care of protecting the measuring circuit. MICRO2- / MICRO3-PROBES: Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit/s is/are protected in the ranges of 5…30A by 1 or 2 FK1 fuse/s with the equivalent current value/s like the original fuse/s. FK1- / FK2- / FK3-PROBES: Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit is protected in the ranges of 5…70A by the original fuse. MCASE- / JCASE-PROBES: Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit is protected in the ranges of 20…60A by 1 JCASE fuse with the equivalent current value like the original fuse. HI-PROBES: Depending on the selected PROBE current measurements may be performed in ranges of 2,5mA…+7.200/-3.000A (peak current when using a 100μΩ-Shunt). The user has to take care of protecting the measuring circuit. U-PROBES: With these PROBES voltage measurements are available in ranges of 170µV…+/- 80V. LI/U-PROBES: These PROBES consist of a voltage and a current PROBEwith same potential. It allows current measuring in range of µA…150A (peak current) and also voltage measuring in range of mV…+/- 80V. The user has to take care of protecting the measuring circuit. HI/U-PROBES: These PROBES consist of a voltage and a current PROBE with same potential. It allows current measuring in range of µA…1.500A (peak current) and also voltage measuring in range of mV…+/- 1000V. The user has to take care of protecting the measuring circuit. T-PROBES: With these PROBES temperature measurements are available in range of -40…+105°C. KLARI-FUSE 2 KLARI-MOD MC3 KLARI-CORD 4-Display BF-Shunt FK-PROBE Special-PROBE

KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

Features

• KLARI-PROBES are the convenient measuring units for low voltage Klaric modules up to 80V.

• For current measurements the PROBES are equipped with low resistive accuracy resistors, for voltage measurements with voltage dividers. Temperature measurements are executed with PT1000 resistance thermometers which are also available in acid resistant version.

• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read out of the PROBE and transmitted to the module.

• The adjustment values are considered for the measurement result calculation. This implicates a very high degree of accuracy.

• Because the shunts only have marginal temperature drift, temperature compensation is not needed.

• A factory calibration is included in scope of delivery. On request we are pleased to offer a DAkkS calibration.

Versions

• LI-PROBES: These PROBES are used to measure currents in range of 0,25µA…150A (peak current). The user has to take care of protecting the measuring circuit.

• MICRO2- / MICRO3-PROBES: Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit/s is/are protected in the ranges of 5…30A by 1 or 2 FK1 fuse/s with the equivalent current value/s like the original fuse/s.

• FK1- / FK2- / FK3-PROBES: Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit is protected in the ranges of 5…70A by the original fuse.

• MCASE- / JCASE-PROBES: Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit is protected in the ranges of 20…60A by 1 JCASE fuse with the equivalent current value like the original fuse.

• HI-PROBES: Depending on the selected PROBE current measurements may be performed in ranges of 2,5mA…+7.200/-3.000A (peak current when using a 100μΩ-Shunt). The user has to take care of protecting the measuring circuit.

• U-PROBES: With these PROBES voltage measurements are available in ranges of 170µV…+/- 80V.

• LI/U-PROBES: These PROBES consist of a voltage and a current PROBEwith same potential. It allows current measuring in range of µA…150A (peak current) and also voltage measuring in range of mV…+/- 80V. The user has to take care of protecting the measuring circuit.

• HI/U-PROBES: These PROBES consist of a voltage and a current PROBE with same potential. It allows current measuring in range of µA…1.500A (peak current) and also voltage measuring in range of mV…+/- 1000V. The user has to take care of protecting the measuring circuit.

• T-PROBES: With these PROBES temperature measurements are available in range of -40…+105°C.

KLARI-FUSE 2 KLARI-MOD MC3 KLARI-CORD 4-Display

BF-Shunt FK-PROBE Special-PROBE

Page 2: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

2

Stan

d Ja

nuar

201

2. A

lle e

rwäh

nten

Mar

ken-

ode

r War

enze

iche

n si

nd E

igen

tum

ihre

r jew

eilig

en B

esitz

er. I

rrtum

und

Tec

hnis

che

Ände

rung

en v

orbe

halte

n.

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

COMBI-PROBES - LI/U - PROBES

HV-LI/U – PROBES consist of a voltage- and a current-PROBE.

Current measurement: • The measuring shunt is placed in a potted casing with cable lead-out for looping-in

the PROBE into the measuring circuit.

• The protection of the measuring circuit has to be provided by the user.

Voltage measurment: • The voltage is measured via a voltage divider.

• The input voltage is reduced to an allowed voltage level for the modules.

PROBE-construction:

potted casing with integrated shunt (type PBV) and voltage divider.

memory device, used for PROBE-identification and calibration data (placed in connector)

I-PROBE, measuring lines for measuring current = L1 (2 x 1m), heat resistant and highly flexible with loose cable ends

U-PROBE, connection-cable for measuring voltage = L3 (0,5m) with loose cable ends

data cable = L2 (1 / 3 / 5m) with 7-pin plug-connector

Caution: The maximum continuous current is lower than the measuring range.

Please refer to the user manual.

Nähere Informationen entnehmen Sie bitte dem Datenblatt.

L2

Shunt with voltage divider

L1 I- / U-

U+

I+

L3

CURRENT-PROBES type PBV

Gain

Measuring Range

[V DC]

Resolution/Bit

[mV/Bit] 100 0...+/- 9 0,3

40 0...+/- 27 0,9

25 0...+/- 42 1,4

5 0...+/- 80 7

1 - -

* indicated for the lowest measuring range ** at room temperature (23°C)

size (l/w/h):50x40x16 mm

VOLTAGE-PROBES type 80V

Ordering: <name> - <resistance value> - <L1> - <L2> - <L3> LI/U - 1000 / … / 2 - 1 - 1 / 3 / 5 - 0,5

Resistor

[mΩ]

Measuring range

[A]

Resolution/Bit*

[mA]

Maximum permanent current**

[A] 1000 -0,3…+0,72 0,25 0,72

500 -0,6…+1,44 0,5 1,44

100 -3…+7,2 2,5 6,5

50 -6…+14,4 5 9,5

25 -12…+28,8 10 12

10 -30…+72 25 21

5 -60…+144 50 25

2 -150…+360 125 40

Page 3: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

3

Stan

d Ja

nuar

201

2. A

lle e

rwäh

nten

Mar

ken-

ode

r War

enze

iche

n si

nd E

igen

tum

ihre

r jew

eilig

en B

esitz

er. I

rrtum

und

Tec

hnis

che

Ände

rung

en v

orbe

halte

n.

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

COMBI-PROBES - I/U-BF1 – PROBES HV-I/U – PROBES consist of a voltage- and a current-PROBE.

Current measurement: • The measuring shunt is placed via mounting straps directly into the measuring circuit

• The protection of the measuring circuit has to be provided by the user

Voltage measurment: • The voltage is measured via a voltage divider

• The input voltage is reduced to an allowed voltage level for the modules

PROBE-construction:

shunt (type BF1) with mounting straps (temperature range -40…+130°C) and voltage divider

memory device, used for PROBE-identification and calibration data (placed in connector)

U-connection-cable = L3 (0,5m), heat resistant and highly flexible with loose cable ends

data cable = L2 (1 / 3 / 5m) with 7-pin plug-connector

Caution: The maximum continuous current is lower than the measuring range.

Please refer to the user manual.

CURRENT-PROBES type BF1

VOLTAGE-PROBES type 80V

Resistor

[mΩ]

Measuring range

[A]

Resolution/Bit*

[mA]

Maximum permanent current**

[A] 2 -150…360 0,125 60

1 -300…+720 0,25 80

0,5 -600…+1440 0,5 120

0,2 -1500…+3600 1,25 150

* indicated for the lowest measuring range

Gain

Measuring range

[V DC]

Resolution/Bit

[mV/Bit] 100 0...+/- 9 0,3

40 0...+/- 27 0,9

25 0...+/- 42 1,4

5 0...+/- 80 7

1 - -

Ordering: <name> - <resistance value> - <L1> - <L2> - <L3> I/U-BF1 - 2 / … / 0,2 - 0 - 1 / 3 / 5 - 0,5

I- U-

U+

Shunt with voltage divider

L2

L3

I+

Page 4: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

4

Stan

d Ja

nuar

201

2. A

lle e

rwäh

nten

Mar

ken-

ode

r War

enze

iche

n si

nd E

igen

tum

ihre

r jew

eilig

en B

esitz

er. I

rrtum

und

Tec

hnis

che

Ände

rung

en v

orbe

halte

n.

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

COMBI-PROBES - I/U-BF2 – PROBES HV-I/U – PROBES consist of a voltage- and a current-PROBE.

Current measurement: • The measuring shunt is placed via mounting straps directly into the measuring circuit

• The protection of the measuring circuit has to be provided by the user

Voltage measurment: • The voltage is measured via a voltage divider

• The input voltage is reduced to an allowed voltage level for the modules

PROBE-construction:

shunt (type BF2) with mounting straps (temperature range -40…+130°C) and voltage divider memory device, used for PROBE-identification and calibration data (placed in connector)

U-connection-cable = L3 (0,5m), heat resistant and highly flexible with loose cable ends

data cable = L2 (1 / 3 / 5m) with 7-pin plug-connector

Caution: The maximum continuous current is lower than the measuring range.

Please refer to the user manual.

CURRENT-PROBES type BF2

VOLTAGE-PROBES type 80V

Ordering: <name> - <resistance value> - <L1> - <L2> - <L3> I/U-BF2 - 2 / … / 0,1 - 0 - 1 / 3 / 5 - 0,5

Resistor

[mΩ]

Measuring range

[A]

Resolution/Bit*

[mA]

Maximum permanent current**

[A] 2 -150…360 0,125 60

1 -300…+720 0,25 80

0,5 -600…+1440 0,5 130

0,2 -1500…+3600 1,25 180

0,1 -3000…+7200 2,5 310

the shunts are linked with a copper bar 20x3,5x200mm * indicated for the lowest measuring range

** at room temperature (23°C)

Gain

Measuring range

[V DC]

Resolution/Bit

[mV/Bit] 100 0...+/- 9 0,3

40 0...+/- 27 0,9

25 0...+/- 42 1,4

5 0...+/- 80 7

1 - -

I- U-

U+

Shunt mit Spannungs-

teiler

L2

L3

I+

Page 5: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

5

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

LI - PROBES

Measuring unit with cable lead-out for looping the PROBE into the measuring circuit. The protection of the

measuring circuit has to be provided by the user. The shunt is integrated in a grouted casing.

Construction: cable lead-out = L1 (1m), (heat resistant and highly flexible) with loose cable ends

grouted casing with integrated shunt

data cable = L2 (1…5 m) with 6-pin push-pull connector

memory device, used for PROBE-identification and calibration data

Caution: The maximum continuous current is lower than the measuring range.

Please refer to the user manual.

LI - PROBES

Ordering: <name> - <resistance value> - <L1> - <L2> - <L3> LI - 1000 / … / 2 - 1 - 1…5 - 0

Resistor

[mOhm]

Measuring range

[A]

Resolution/Bit*

[µA]

Maximum permanent current **

[A] 1000 -0,3…+0,72 0,25 0,72

500 -0,6…+1,44 0,5 1,44

100 -3…+7,2 2,5 6,5

50 -6…+14,4 5 9,5

25 -12…+28,8 10 12

10 -30…+72 25 21

5 -60…+144 50 25

2 -150…+360 125 40

* indicated for the lowest measuring range ** at room temperature (23°C) size (l/w/h): 50x40x16mm

L1 L2

Page 6: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

6

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

MICRO2 - PROBES

Measuring unit with MICRO2 connector, which is plugged into the vehicle’s fuse holder instead of the

original fuse. The measuring circuit is protected by a FK1 fuse with the equivalent current value to ensure

that the measuring circuit is protected. The FK1 fuse is plugged into the fuse holder at the aluminium

casing. The measuring shunt is integrated in the casing.

Construction: MICRO2 connector

cable with fuse = L1 (highly flexible and heat resistant)

aluminium casing with integrated shunt and fuse holder for measuring circuit protection

data cable = L2 (1…5m) with 6-pin push-pull-connector

memory device, used for PROBE-identification and calibration data

Caution: The maximum continuous current may be lower than the measuring range.

Please refer to the user manual.

MICRO2 - PROBES

Ordering: <name> - <fuse value> - <L1> - <L2> - <L3> MICRO2 - 5 / … / 30 - 1 / 3 - 1…5 - 0

Type

Measuring range

[A] Resolution/Bit*

[µA] R

[mΩ]

Cross section [mm2]

5 A 5 10 25 1,5

10 A 10 25 10 2,5

20 A 20 50 5 4

30 A 30 125 2 4

size (l/w/h): 50x41x20mm

* indicated for the lowest measuring range

L1

L2

FK1- fuse holder

measuring shunt

Page 7: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

7

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

MICRO3 - PROBES

Measuring unit with MICRO3 connector, which is plugged into the vehicle’s fuse holder instead of the

original fuse. The measuring circuits are protected by 2 FK1 fuses with the equivalent current values to

ensure that the measuring circuits are protected. The FK1 fuses are plugged into the fuse holders at the

aluminium casing. The 2 measuring shunts are integrated in the casing.

Construction: MICRO3 connector

cable with fuse = L1 (highly flexible and heat resistant)

aluminium casing with integrated 2 shunts and 2 fuse holders for measuring circuit protection

data cable = L2 (1…5m) with 6-pin push-pull-connector

memory device, used for PROBE-identification and calibration data

Caution: The maximum continuous current may be lower than the measuring range.

Please refer to the user manual.

MICRO3 - PROBES

Ordering: <name> - <fuse value> - <L1> - <L2> - <L3> MICRO3 - 5 / 10 - 1 / 3 - 1…5 - 0

Type

Measuring range

[A] Resolution/Bit*

[µA] R

[mΩ]

Cross section [mm2]

5 A 5 10 25 1,5

10 A 10 25 10 2,5

20 A 20 50 5 4

size (l/w/h): 80x55x24mm

* indicated for the lowest measuring range

L1

L2

2 FK1 fuse holder

L2

measuring- shunt

measuring- shunt

Page 8: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

8

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

Type

Measuring range

[A] Resolution/Bit*

[µA] RNenn

[mΩ]

Cross section [mm2]

5 A 5 10 25 1,5

10 A 10 25 10 2,5

20 A 20 50 5 4

30 A 30 125 2 4

size (l/w/h): 50x41x20mm

* indicated for the lowest measuring range

FK - PROBES

Measuring unit with FK1-, FK2- or FK3-connector, which is plugged into the vehicle’s fuse holder instead

of the original fuse. The original fuse has to be plugged into the PROBE’s fuse holder to ensure that the

measuring circuit is protected. The fuse holder and the shunt are integrated in a small aluminum casing.

Construction: FK1-, FK2-, FK3- connector

cable with fuse = L1 (highly flexible and heat resistant)

aluminium casing with integrated shunt and fuse holder for measuring circuit protection

data cable = L2 (1…5m) with 6-pin push-pull-connector.

memory device, used for PROBE-identification and calibration data.

Caution: The maximum continuous current may be lower than the measuring range.

Please refer to the user manual.

FK1 - PROBES

Ordering: <name> - <fuse value> - <L1> - <L2> - <L3> FK1 - 5 / … / 30 - 1…3 - 1…5 - 0

L1

L2

FK fuse holder measuring- shunt

Page 9: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

9

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

FK2 - PROBES

FK3 - PROBES

Type

Measuring range

[A] Resolution/Bit*

[µA] RNenn

[mΩ]

Cross section [mm2]

5 A 5 10 25 1,5

10 A 10 25 10 2,5

20 A 20 50 5 4 size (l/w/h): 50x41x20mm

Type

Measuring range

[A] Resolution/Bit*

[µA] RNenn

[mΩ]

Cross section [mm2]

30 A 30 125 2 4

40 A 40 250 1 4

size (l/w/h): 80x55x24mm

* indicated for the lowest measuring range

Ordering: <name> - <fuse value> - <L1> - <L2> - <L3> FK2 - 5 / … / 40 - 1…3 - 1…5 - 0

Ordering: <name> - <fuse value> - <L1> - <L2> - <L3> FK3 - 30 / 50 / 70 - s.table - 1…5 - 0

Type

Measuring range

[A] Resolution/Bit*

[µA] RNenn

[mΩ] L1

[m]

Cross section [mm2]

30 A 30 125 2 1 / 3 4

50 A 50 250 1 1 6

70 A 70 500 0,5 0,5 6

size (l/w/h): 80x55x24mm

* indicated for the lowest measuring range

Page 10: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

10

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

JCASE - and MCASE - PROBES

Measuring unit with JCASE or MCASE connector, which is plugged into the vehicle’s fuse holder instead

of the original fuse. The measuring circuit is protected by a JCASE fuse with the equivalent current value

to ensure that the measuring circuit is protected. The JCASE fuse is plugged into the fuse holder at the

aluminium casing. The measuring shunt is integrated in the casing.

Construction: JCASE or MCASE connector

cable with fuse = L1 (highly flexible and heat resistant)

aluminium casing with integrated shunt and fuse holder for measuring circuit protection

data cable = L2 (1…5m) with 6-pin push-pull-connector

memory device, used for PROBE-identification and calibration data

Caution: The maximum continuous current may be lower than the measuring range.

Please refer to the user manual.

L1

L2

JCASE fuse holder

measuring-shunt

Type

Measuring range

[A]

Resolution/Bit*

[µA]

R

[mΩ]

L1

[m]

Cross section

[mm2] JCASE 20 50 5 1 / 3 2x2,5 / 4

JCASE 30 125 2 1 / 3 2x2,5 / 4

JCASE 40 250 1 1 / 3 2x2,5 / 4

size (l/w/h): 80x55x24 mm

Type

Measuring range

[A]

Resolution/Bit*

[µA]

R

[mΩ]

L1

[m]

Cross section

[mm2] JCASE 50 250 1 1 6

JCASE 60 500 0,5 0,5 6

size (l/w/h): 80x105x26mm

* indicated for the lowest measuring range

JCASE - PROBES

Bestellung: <Name> - <Sicherungswert> - <L1> - <L2> - <L3> JCASE - 20 / … / 60 - s.Tab. - 1…5 - 0

Page 11: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

11

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

Type

Measuring range

[A]

Resolution/Bit*

[µA]

R

[mΩ]

L1

[m]

Cross section

[mm2] MCASE 20 50 5 1 / 3 2,5

MCASE 30 125 2 1 / 3 2,5

MCASE 40 250 1 1 / 3 2,5

size (l/w/h): 80x55x24 mm

Type

Measuring range

[A]

Resolution/Bit*

[µA]

R

[mΩ]

L1

[m]

Cross section

[mm2] MCASE 50 250 1 0,5 2,5 / 4

MCASE 60 500 0,5 0,5 2,5 / 4

size (l/w/h): 80x105x26mm

* indicated for the lowest measuring range

MCASE - PROBES

Ordering: <name> - <fuse value> - <L1> - <L2> - <L3> MCASE - 20 / … / 60 - s.table - 1…5 - 0

Page 12: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

12

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

HI – PROBES (without measuring circuit protection) At these PROBEs the shunt has to be placed directly into the measuring circuit.

The protection of the measuring circuit has to be provided by the user.

Construction: Shunt (type BF1 or BF2) with mounting straps (temperature range -40…+130°C)

data cable = L2 (1…5m) with 6-pin push-pull connector

memory device, used for PROBE identification and calibration data

Caution: The maximum continuous current is lower than the measuring range.

Please refer to the user manual.

L2

HIGH-CURRENT - PROBES

BF 1

BF 2

Ordering: <name> - <resistance value> - <L1> - <L2> - <L3> HI-BF1 - 2 / … / 0,2 - 0 - 1…5 - 0 HI-BF2 - 2 / … / 0,1 - 0 - 1…5 - 0

Resistor

[mΩ]

Measuring range

[A]

Resolution/Bit*

[mA]

Maximum permanent current**

[A] 2,5 -120…+288 0,1 60

1 -300…+720 0,25 80

0,5 -600…+1440 0,5 120

0,2 -1500…+3600 1,25 150

size (l/w/h): 42x16x15mm the shunts are linked with a copper bar 20x3x200mm * indicated for the lowest measuring range ** at room temperature (23°C)

Resistor

[mΩ]

Measuring range

[A]

Resolution/Bit*

[mA]

Maximum permanent current**

[A] 2 -150…360 0,125 80

1 -300…+720 0,25 120

0,5 -600…+1440 0,5 130

0,2 -1500…+3600 1,25 180

0,1 -3000…+7200 2,5 310

size (l/w/h): 68x27x15mm the shunts are linked with a copper bar 20x3,5x200mm * indicated for the lowest measuring range ** at room temperature (23°C)

Page 13: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

13

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

HI

grouted HI-PROBE

Various resistors and PROBE types available. We would be pleased to help you finding the appropriate PROBE for your measuring task.

BF3 - SHUNT

Resistor

[mΩ]

Measuring range

[A]

Resolution/Bit*

[mA]

Maximum permanent current**

[A] 0,05 -6000…+8000 5 300

0,025 -8000…+8000 10 420

HI-SPECIAL-PROBES

Resistor

[mΩ]

Measuring range

[A]

Resolution/Bit*

[mA]

Maximum permanent

current shunt**

[A] 0,2 -1500…3600 1,25 150

0,1 -3000…+7200 2,5 250

0,05 -6000…+8000 5 300

0,025 -8000…+8000 10 400

size: (l/w/h): 150x65x40mm (without cables) * indicated for the lowest measuring range ** at room temperature (23°C) the maximum permanent current is limited by the cross-section

of the connected cables L1:

selectable: 35mm2 / 70mm2 allowed max. permanent current at 80°C: 200A / 305A - for installation in a drug battery-box instead of the stud between the batteries - Standard connection cable shoe, other connections after consultation with us

size: (l/w/h): 90x42x15mm the shunts are linked with a copper bar 20x3x200mm * indicated for the lowest measuring range ** at room temperature (23°C)

Ordering: <name> - <resistance value> - <L1> - <L2> - <L3>

HI-BF3 - 0,05 / 0,025 - 0 - 1…5 - 0

Ordering: <name> - <resistance value> - <L1> - <L2> - <L3> HI-SPECIAL - 0,2 / … / 0,025 - 0,7 - 1…5 - 0

Page 14: KLARI-PROBES• All KLARI-PROBES have a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read

14

Stat

us J

anua

ry 2

019.

All

men

tione

d tra

dem

arks

or b

rand

s ar

e pr

oper

ty o

f the

cor

resp

ondi

ng o

wne

r. Su

bjec

t to

erro

r and

tech

nica

l cha

nges

.V21

KLARI-PROBES

ACCESSORIES

T - PROBE (acid-resistant) PT1000 sensor for temperature measurements

temperature measuring range: -40 to +105°C

data cable = L2 (1…5m)

PT1000 sensor cable = L1 (2m)

U - PROBE voltage measuring unit

measuring range +/-80V

resolution: 170µV/Bit

data cable: 1m

measuring cable: See below / depends on variant

total length: data cable + measuring cable

Gain

Measuring range

[V]

Resolution/Bit*

[µV] 100 +/- 5 170

50 +/- 10 340

24 +/- 20 680

6 +/- 80 2720

* indicated for the lowest measuring range

Extension cable for the PROBES

Ordering: <name> - <L1> - <L2> - <L3> T-80V - 2 - 1…5 - 0

Ordering: <name> - <L1> - <L2> - <L3> U-80V - 1…5 - 1 - 0

Ordering: <name> - <L1> - <L2> - <L3> PROBE-EXT-80V - 0 - 2 / 4 - 0