The design for ion exchange column

Jiali Wang + Kenchouw Wu

March 2015

Page 2: Jiali Wang + Kenchouw Wu March 2015 - Oasen

ii

Page 3: Jiali Wang + Kenchouw Wu March 2015 - Oasen

iii

The design for ion exchange column

(Internship report)

Submitted to:

Mr. Harmen van der Laan (Oasen Drinking water company)

Ms. C. Mok Kai Rine (The Hague University)

Submitted by:

Jiali Wang + Kenchouw Wu

BSc. Students Process and Food Technology

The Hague University

Date of submission:

March 2015

Page 4: Jiali Wang + Kenchouw Wu March 2015 - Oasen

iv

Page 5: Jiali Wang + Kenchouw Wu March 2015 - Oasen

v

Summary

The aim of the work described in this report was to design an ion exchange column for the

removal of ammonium ions from RO permeate. The ion exchangers used in this research project

were i) clinoptilolite, a naturally occurring zeolite and ii) a resin in H+ form with functional group

sulfonic acid (Lewatit S2568H). A four columns set-up has been designed based previous research

done by Mikkers (2009) in which above described ion exchangers have been used. The main

scope of this report was to look at the influence of surface loading and bed height on the

ammonium removal capacity. Several experiments were conducted with varying bed heights (5 –

20cm), flow rates per column (12 – 100L/h) and the two ion exchange media.

The results of experiments were compared with those of the previous research studies done by

KWR (2005) and Ekowati (2014) and were found to be comparable. The zeolite was found to have

a 7 times lower breakthrough capacity compared to the Lewatit resin. The average breakthrough

capacity was found to be 2.17 mg NH4 per gram for the resin. Due to the influence of the film

diffusion, the breakthrough capacity was similar for different surface loading rates.

The results were used to design an ion exchange column for the new to build water treatment at

ZS De Hooge Boom. Using the average breakthrough capacity from the experiments a design was

made for four ion exchange vessels with each a capacity of 120m3/h, a bed height of 2m, and

surface loading of 99m/h, and Empty Bed Contact Time (EBCT) of 1.2minutes and a breakthrough

time of 10 days. The costs were estimated to be €0.014 per m3.

Recommendations for future research are to conduct experiments with higher bed heights (60 –

100cm) and to use a ammonium dosing in the feed water to vary with different ammonium

concentrations.

Keywords: Ion exchange column, zeolite, resin, surface loading, bed height

Page 6: Jiali Wang + Kenchouw Wu March 2015 - Oasen

vi

Page 7: Jiali Wang + Kenchouw Wu March 2015 - Oasen

vii

Contents

1. Introduction and research question .............................................................................................. 1

1.1 Oasen Drinking Water Company ............................................................................................. 1

1.2 Drinking water treatment "De Hooge Boom" ......................................................................... 1

1.3 The research project ............................................................................................................... 2

1.4 Previous research .................................................................................................................... 2

1.5 Problem introduction .............................................................................................................. 3

1.6 Boundary conditions ............................................................................................................... 3

1.7 Outline of the report ............................................................................................................... 4

2. Theoretical background ................................................................................................................ 5

2.1 Ion Exchange ........................................................................................................................... 5

2.2 Selectivity of ion exchange ...................................................................................................... 6

2.3 Kinetics of Ion Exchange .......................................................................................................... 7

2.3.1 Kinetics ............................................................................................................................. 7

2.3.2 Parameters in Ion Exchange ............................................................................................. 8

2.3.3 Ion Exchange capacity ...................................................................................................... 9

2.3.4 Breakthrough ................................................................................................................. 10

3. Methods and materials ............................................................................................................... 11

3.1 Set-up .................................................................................................................................... 11

3.2 Materials ............................................................................................................................... 12

3.3 Measurement methods......................................................................................................... 12

3.4 The validation of spectrophotometer Hach-Lang DR 2800 ................................................... 12

3.5 The validation of ammonium analyzer Applikon Colorimeter .............................................. 13

3.6 The validation of ammonium dosing pump .......................................................................... 14

4. Results ......................................................................................................................................... 17

4.1 The performance of 10 and 20 cm Lewatit S2568H .............................................................. 17

4.2 Comparison between Lewatit S2568H and clinoptilolite ...................................................... 20

4.3Comparison between clinoptilolite with different particle size ............................................. 20

5. Discussion .................................................................................................................................... 21

5.1 Influence of bed height ......................................................................................................... 21

5.2 Influence of flow rate ............................................................................................................ 21

5.3 Kinetics .................................................................................................................................. 22

5.4 Performance of zeolite and resin .......................................................................................... 22

Page 8: Jiali Wang + Kenchouw Wu March 2015 - Oasen

viii

5.5 Influence of particle size. ...................................................................................................... 22

5.6 Difficulties of doing pilot experiments .................................................................................. 22

6. Ion exchange column design calculation ..................................................................................... 23

6.1 Introduction .......................................................................................................................... 23

6.2 Design calculation ................................................................................................................. 23

7. Conclusion and recommendations for future research .............................................................. 27

7.1 Conclusion ............................................................................................................................. 27

7.2 Main uncertainties in the research and design ..................................................................... 28

7.3 Recommendations for future research ................................................................................. 28

Reference ........................................................................................................................................ 29

Appendix A: Drinking water quality standards ............................................................................ 30

Appendix B: Schematic drawing Set-up by Yvonne Mikkers ....................................................... 32

Appendix C: Material data sheet ................................................................................................. 33

Appendix D: The results of validation of equipment’s ................................................................ 39

Appendix E: Measuring reports .................................................................................................. 42

Appendix F: The design of future treatment plant ..................................................................... 56

Appendix H: The pressure drop data of Lewatit S2568H ............................................................ 57

Page 9: Jiali Wang + Kenchouw Wu March 2015 - Oasen

1

1. Introduction and research question

1.1 Oasen Drinking Water Company Oasen, is an public drinking water supply company with 130 years’ history. It offers drinking water to 750.000 people and 7.200 companies in the south east Holland. (Figure 1.1.1) The purpose of Oasen is to make sure that the water is of impeccable quality and the same level quality of drinking water should be always kept.

Figure 1.1.1 Oasen’s supply area

Every year, Oasen provides its customers with 48 billion liters of drinking water produced from groundwater.

1.2 Drinking water treatment "De Hooge Boom" Drinking water treatment plant "De Hooge Boom" is located in Kamerik, South Holland, with total capacity of 3.000.000 m3 per year. In 2013, Oasen started its multi-annual plan ’Better than Possible’, which will be put into practice at De Hooge Boom in the future. The current treatment processes showed in (Figure 1.2.1 and Figure 1.2.2) have been producing water with good quality that meets the standards.

Figure 1.2.1 Drinking water treatment plant De Hooge Boom

Page 10: Jiali Wang + Kenchouw Wu March 2015 - Oasen

2

Figure 1.2.2 Treatment scheme in “De Hooge Boom” treatment plant (Source: Yuli Ekowati, 2014) Figure 1.2.3 shows the plan of new treatment processes that will be operated in the near future in De Hooge Boom.

Figure 1.2.3 New treatment scheme for “De Hooge Boom” treatment plant (Source: Yuli Ekowati, 2014)

1.3 The research project The raw water at the ZS De Hooge Boom is distracted from a deeper level where the water originates from the river. This is called river bank filtrate. It does not reach the quality standard of drinking water in the Netherlands

(See Appendix A); even though the groundwater is naturally purified after it moves so slowly in the subsurface. In the new to build treatment plant de Hooge Boom, the raw water passes through RO (reverse osmosis) membrane filters first. Then another treatment step is required, because the ammonium removal by the membrane technique is not good enough at present. It results in the higher concentration of ammonium in the RO permeate (up to 0.6mg/L), whereas the limit is 0.03mg/L. In order to reach the purpose, ion exchange technology is selected to be applied in this research project. This research project focuses on this part of new to build the treatment: the ion exchange step to remove ammonium.

1.4 Previous research This research is performed based on previous studies about ion exchangers’ efficiency and regeneration. In summary, the research of KWR, Yuli Ekowati and Yvonne Mikkers provide essential ideas and information for this research project.

KWR, 2005 Research topic: Ammonium removal in drinking water using natural zeolite In the research experiments, in order to make the experiment condition more persuasive and accurate, ammonium chloride solution was added in to the dematerialized water. The KWR research has founded out the two main effects on ammonium removal capacity:

o The grain size of the clinoptilolite (done by feed water with 2 mg NH4+/L)

o The initial ammonium concentration in aqueous solution (done by feed water with 0.05-10 mg NH4

+/L) It was found that ammonium removal was faster with the smaller grains and a high removal capacity is obtained quickly. An increase in ammonium concentration in the solution will result in an increasing ammonium removal capacity by clinoptilolite.

Yvonne Mikkers, 2009 – Ammonium removal with zeolite on anaerobic groundwater In this research, the effectiveness of chemical regeneration of two kind zeolites which were used to remove ammonium from groundwater has been studied at Oasen. To perform the experiments, Yvonne designed the set-up (see Appendix B) for pilot scale study from which the idea for the present research’s column set-up came. In her research experiments, the raw water with average NH4

+ concentration of 6.5 mg/L was used as feed water.

Page 11: Jiali Wang + Kenchouw Wu March 2015 - Oasen

3

Yuli Ekowati, 2014 In this research, the efficiency of ion exchange resin/zeolite in removing low concentration of ammonium was investigated at Oasen in Kamerik, as a part of the research program. Based on Yuli’s literature research, several adsorption isotherms for calculation of run length for zeolite were found. According to the experimental data, the KWR report (2005) provides the most accurate/realistic adsorption isotherm. This adsorption isotherm will be used in the present research for calculating breakthrough run length of zeolite. Furthermore, she made the present setup, but was not able to reach the breakthrough of resin.

1.5 Problem introduction 1.5.1 Ammonium in ground water In the Netherlands, the groundwater is required to be treated before it becomes drinking water. High ammonium concentration in the groundwater needs to be lower at a certain level. Reason is that the nitrogen can maybe serve as nutrient for some bacteria. Furthermore, NH4

+ can be formed to nitrite which is a cause of health problems if the amount of nitrite occurred in the drinking water exceed the maximum contaminant level allowed. To solve the problem, the ion exchange is regarded as an effective post treatment to remove ammonium. 1.5.2 Research question The Oasen Drinking Water Company, is planning to build a new treatment plant in De Hooge Boom, Kamerik in 2018. And the new treatment plant will employ ion exchange technique after ground water experiences filtration of the RO (reverse osmosis) membrane. This effluent called permeate water attains a relative lower concentration of ammonium, which becomes the influent to pass ion exchange step. At the beginning, the concentration of ammonium is around 0.1 mg NH4+/L, and the target ammonium concentration in the outflow is required to achieve <0.03 mg NH4+/L. At present, resin and zeolite are two main ion exchange materials (see chapter 2) in water treatment. In order to determine the efficiency of zeolite and resin to be appropriately applied in lower ammonium removal, the research question is defined as follow:

What should be the design of the ion exchange post treatment step for permeate when it comes to surface loading and bed height?

Sub questions:

What is the influence of the surface loading (which is flow rate of feed water on the effectiveness of ammonium removal by ion exchange)?

What is the influence of the bed height of the ion exchange for the effectiveness of ammonium removal?

1.6 Boundary conditions For this research project, the limited conditions were described as following. Due to the limited time for only two months, it was not possible to do experiments related to every parameter that has influence on ammonium removal in ion exchange process. Based on the plan of action, three main parameters should be considered in experiments: (1) bed heights of ion exchange, (2) initial concentration of ammonium in feed water and (3) flow rate of feed water. In literature, the important parameters also include temperature of water, particle size of ion exchangers, pH level and etc. In the project, only different bed heights of ion exchangers and different flow rates of permeate water has been done. For different initial concentration of ammonium, it had been ever planned to utilize a dosing pump for getting a higher ammonium concentration in feed water. But it was not successful; because the dosing

Page 12: Jiali Wang + Kenchouw Wu March 2015 - Oasen

4

ammonium solution didn’t mix well with permeate water (see in chapter 3). Last but not least, the concentration of ammonium after the RO (reverse osmosis) membrane could not maintain a stable level in the duration of the project. That is due to the groundwater comes from different wells. In this case, the breakthrough capacities, SFR (service flow rate) and the design of full scale will be influenced (see chapter 4 and 5).

1.7 Outline of the report In chapter 2 the general theory of ion exchange will be presented. Chapter 3 will go about the description of pilot setup, materials, and measurement methods. The experiment results will be shown in chapter 4. In chapter 5 the results will be discussed and compared with previous research studies. And the difficulties of doing pilot scale will be discussed as well. In chapter 6 the ion exchange design will be given and finally, in chapter 7 the conclusion of this report will be presented.

Page 13: Jiali Wang + Kenchouw Wu March 2015 - Oasen

5

2. Theoretical background

2.1 Ion Exchange Ion exchange is used in water treatment to remove the unwanted soluble ionized substances from water being treated. Ion exchange resins can be divided into two groups. One is the polymer on which the fixed groups are permanently ionized at. The fixed groups are positive or negative charged. To keep the resin electrical neutral, ions of opposite charge have to attached on it. The ions of opposite charge are unlike the fixed groups, exchange with mobile ions from water, are so called counter-ion. The ions that have the same charge as that of the fixed groups (exchange sites) are known as co-ions. Figure 2.1 shows an example of cation exchange resin bead.

Na+ = mobile ions (counter-ions) SO3

- =fixed group Dark line = polymeric skeleton Figure 2.1. Schematic cation exchange resin bead (Rohm and Haas, 2008)

An ion exchange that is capable of exchanging cations are known as cation exchange, and capable of exchanging anions are known as anion exchange. An overview of the compositions can be made as follows:

Type Fixed groups Counterions Coions

Cation exchange - + -

Anion exchange + - + Another one is the inorganic ion exchange. The inorganic materials initially used were natural crystalline aluminosillicates which had cation exchange properties. (B.A.Bolto and L.Pawlowski,1987). Ammonium can be removed from water by strongly acidic cation resins or by zeolites. The most used zeolite type for the application in removing ammonium is clinoptlolite. They remove ammonium more selectively with little competition from other cations (George J. Crits, 2012). The matrix made of aluminum, silicates and oxygen is highly negatively charged, because of the shared oxygen atoms between aluminum and silicon. To keep electrical neutrality, the zeolites are commonly neutralized with sodium, potassium and calcium. It is of importance that the zeolite prefers ammonium ion over them. The adsorbent is exchanged for an unwanted ion (for example NH4

+ ions) in the water. For the sake of accomplishing the exchange reaction, a packed bed of ion-exchange resin beads or zeolite is used. Raw water is continually passed through the bed in a down flow or up flow mode until the adsorbent is exhausted, as evidenced by the appearance (breakthrough) of the unwanted contaminant at an unacceptable concentration in the effluent. Also, it is regarded that the most effective ion exchange reactions are reversible. Zeolite is inorganic and other important kind of ion exchangers in ion exchange application for water treatment. There is one sample of zeolite show in figure 2.2 about the ion exchange process.

Page 14: Jiali Wang + Kenchouw Wu March 2015 - Oasen

6

Figure 2.2 Ion-Exchange on a zeolite (Source: Schmidt, 2008)

In figure 2.2, the mobile ions are sodium that is loosely held by the zeolite. The fixed ions are aluminosilicates. To remove ammonium ions (NH4

+), the groundwater is passed through a column filled with sodium (Na+) form zeolites. So ammonium ions going into the zeolite will be replaced by sodium ions getting out of it and dissolving in the water. In above process, the exchange reaction can be written as:

(R- Na+) + NH4+ (R- NH4

+) + Na+

The brackets represents the zeolite matrix phase, R- is aluminosillicates.From the reaction equation it can be seen that the salinity of the water remain the same, only the composition of the salinity is changed at the end of the process. Of course, the exchange is limited. The total ion-exchange capacity is determined by the concentration of fixed charges. It describes the maximum amount of unwanted substances which have been replaced and there is no place more for removing more. In other word, ion exchange is an intrinsic property of ion exchange material. There are two necessary requirements for ion exchange reaction: (1) the ion exchange material immerses in solution, and (2) the solution contains unwanted ions.

2.2 Selectivity of ion exchange The ion exchange can only work efficiently when there is a difference in affinity for counterions in the resin and those in the external solution. In the zeolites, ammonium ions can be removed selectively from water, because zeolites have more affinity for the ammonium than for the sodium ions. The selectivity of a variety of cations on clinoptilolite shows (Langwaldt, 2008):

Cs+> Rb+ > K+ > NH4+> Ba2+ > Sr2+ > Na+ > Ca2+ > Fe3+> Al3+ > Mg+ > Li+

Fortunately, there are no Cs+, Rb+ , K+ presented in the permeate at De Hooge Boom.The selectivity for a certain ion is determined by the selectivity coefficient Ks applied to the cation exchange in the reaction equation as follows:

(R- A+) + B+ (R- B+) + A+

Ks=[(R−B+)] [A+]

[(R−A+)] [B+]

The Ks describes how counterions are present in the exchange beads and solution when the exchange in the A+ form is placed in a solution having B+ ions. The value of Ks might be dependent on the porosity and the

Page 15: Jiali Wang + Kenchouw Wu March 2015 - Oasen

7

concentration of the solution. From the equation, it seems that the affinity of zeolite for ammonium increases as the concentration of it increases in the solution. Also, the selectivity coefficient Ks relies on various factors (Kunin R, 1951):

1. Higher valence ions are more preferred: Tetravalent > Trivalent > Divalent > Monovalent Th4+>Fe3+>Ca2+>K+ PO4

3->SO42->Cl-

2. Least hydrated ion is the most preferred:

The higher the ionic radius, the lower is the radius of the hydrated ion. Cs+>Rb+>K+>Na+>Li+ SCN->ClO4

->I->NO3->Br->CN-

3. Ions with greater ability to polarize are preferred:

NO3-> Br-> NO2

-> Cl-

4. Ions with least tendency to form complexes in solution: Cl-> HCO3

-> CH3COO-> OH->F-

2.3 Kinetics of Ion Exchange

2.3.1 Kinetics

The kinetic mechanism is important factor to consider when it comes to mass transfer. The main mechanism in ion exchange is summarized as follows (also see Figure 2.3.1.1):

Ions in solution travel through the bulk of the solution (diffusion in solution)

Diffusion of the specific ions from bulk liquid to a boundary layer surrounding the bead. (film diffusion)

Diffusion through the boundary layer to the outer surface of the bead.

Diffusion from the bead surface into the pores of the bead. (particle diffusion)

Exchanging of counterions at the fixed site.

Film

Film

Diffusion in solution

(Solution)

Film diffusion

(Resin)

Particle diffusion

Figure 2.3.1.1 Schematic description of ion exchange process (source: Wang, 2015) The rate is determined by the slowest kinetic step, thus the ion exchange reaction will not be taken into consideration. Depending on the conditions, either film diffusion or particle diffusion is rate controlling. The

Page 16: Jiali Wang + Kenchouw Wu March 2015 - Oasen

8

other factors are insignificant and can be ignored. (Tony C. Jorgensen, 2002)

2.3.2 Parameters in Ion Exchange

Ion exchanger type On the basis of origin, there are two general types of ion exchange materials, they are resins and natural exchangers; for the former one, the majority are synthetic polymers available in cationic and anionic forms whereas the latter exists in cation-exchange form only (e.g., zeolites and betonites). Thus, synthetic ion exchange materials can be cationic, anionic, and combined cationic/anionic (amphoteric) exchangers considering the nature of fixed ion exchange sites (functional groups). pH The performance of ion exchange is influenced by the pH of the solution. In the experiments done by (R.R.Harries, 1988), it can be concluded that anion exchange is faster in an acidic medium and cation exchange is more rapid in alkaline medium. Anion exchange To find the relation between anion exchange kinetics and pH, the mass transfer coefficient of chloride and sulphate were tested in the condition where strong base resin was used. It’s found that there is a strong decrease in chloride or sulphate exchange kinetics in moving from an acidic influent to a neutral or alkaline influent. The reaction occurring during the exchange can be represented by the following equation:

(R+ OH-) + A- ↔ (R+ A-) + OH-

R+ is the charged matrix and A- is chloride or sulphate. Based on the above, anion exchange is more favorable under acidic environment. The reaction will be more shifted towards the right when there are enough H+ reacting with OH- . Cation exchange The variation of cation exchange kinetics with pH was carried out. Sodium and ammonium ions were tested in the condition where strong acid resin was used. There was an increase in exchange rate as the pH was increased. If the permeate has a pH of 5 which is basic, it would help to increase the pH. Thus it would also to increase ion exchange rate. Initial ammonium concentration In the presence of low ammonium concentration, the running time will be very long. When the concentration is high, the ion exchange reaches the breakthrough quickly which results in high demand of regenerates to uneconomical levels. Besides the high affinity discussed before, it also has influence on the particle diffusion. In dilute solutions (usually below 0.001M), film diffusion is rate controlling. In this research project, the film diffusion is expected to be rate determined. In more concentrated solutions (usually above 0.1 M), particle diffusion is a rate determined factor. (B.A. Bolto and L. Pawlowski, 1987) This can be explained that dilute solutions increase the flow rate of water through the pores of the bead. Particle size From described above, it can be seen that the exchange rate in concentrated solutions can be improved by the decreasing of the particle size. Higher productivity can be obtained by using smaller particle size which provides a larger surface area. But the particle is allowed to reduce to a certain size, because of a high pressure lose in the process. The rate is inversely proportional to the particle radius when film diffusion dominated, and inversely proportional to the square of the radius when the rate-limiting step is particle diffusion.(Helfferich,F., 1962) In this project, the chosen particle size range of zeolite is 1.0-2.5 mm or 0.3-1.0 mm. Lewatit S2568H has its

Page 17: Jiali Wang + Kenchouw Wu March 2015 - Oasen

9

mean bead size of 0.65 mm. The smaller particle size of Lewatit S2568H could increase its ion exchange rate. Volumetric flow rate At a low flow rate, there is a static water layer around the resin held by friction. The diffusion of ions through the matrix of the resin is faster than the diffusion of ions across the static film. The film diffusion is a rate determining factor and the film becomes denuded of ammonium. In an example of ammonium containing solution flowing down resin in H+ form, there would be a lot of difference of components between an upper layer of resin in the ammonium form and a down layer of resin in the H+ form. The upper layer is surrounded by ammonium ions and the lower layer is surrounded by H+. It could happen when the flow is so slow that the rate of arrival of ammonium ions is similar to that of diffusion through the static film. Thus, there is no need for ammonium ions to enter another lower layer of resin. Another reason might be the low flow rate increases the contact time. In comparison to it, the rate of ammonium ions arrives on the resin is faster than the rate of diffusion through the static film at a certain high flow rate. As a consequence, the sharp distinction between layers in H+ form and Na+ form will be disappeared. Therefore, the breakthrough point at a low flow rate is higher than that at the higher flow rate. Also the quality of effluent is obtained as the contact time increases with a decrease in flow rate. However the total ion exchange capacity would be the same under both conditions after passage of excess solution. In the practice of water treatment, it is recommended to terminate the run at the breakthrough point. By combining the flow rate and ionic concentration of the water, the breakthrough curve is plotted. (T.V.Arden, et al., 1968) Regeneration

At a certain point, the resins are saturated with unwanted substances, they can be used again by bring them back to the fresh state. Since a suitable time is needed for the required degree of regeneration, the best way of regenerating resins is to let regenerant go through columns with deep beds. The deeper the bed, the more efficient of the regenerant. Because the resin can have more time in contact with regenerant. For example, Zeolite is regenerated with sodium ions obtained by NaCl. The regeneration reaction:

RNH4 + NaCl ↔ RNa + NH4Cl Ammonium ions within the zeolite are released into the solution and replaced by sodium ions from the NaCl solution. For this regeneration, high concentration of NaCl is required since the reaction is reversible. Regeneration not only optimizes the exchange capacity but also reduces the ion leakage. The concentrated NaCl helps to remove contaminants at the bottom of the resin effectively within a short time. After regeneration rinsing is required. In this case, the remained Cl- and Na+ have to be removed.

2.3.3 Ion Exchange capacity

The exchange capacity of an ion exchange material is a measurement of the ability, in which of an insoluble material to experience replacement of ions previously attached and loosely incorporated into its structure, by oppositely charged ions present in the surrounding solution. It is a constant value for a given exchange material. The unit is expressed as mg/g of dry resin. There are two capacity parameters to characterize ion exchangers: the total static capacity and the dynamic capacity. The former is determined under static conditions, while the latter is determined by passing the solution through a bed of the exchanger (usually a packed bed or a in a column). Actually, in practice, this capacity can never be exploited due to interference from coexisting counterions. In a column type exchanger, the operating capacity or the breakthrough capacity bases on the concentration of the ions being removed, the effects of interfering ions, ionic size, ionic valence, design of the column, and operating parameters.

Page 18: Jiali Wang + Kenchouw Wu March 2015 - Oasen

10

2.3.4 Breakthrough

A plot (see Figure 2.3.4.1) between the concentrations of the removed ions in the effluent (ordinate) versus the effluent volume (abscissa) is drawn. The breakthrough is defined as the point where the unwanted ions in the effluent appear in appreciable quantity. (c, start of breakthrough). The extent of breakthrough rises to a point e where no more ion exchange occurs, that is, the effluent includes the original concentration of the ions. This point records the stage at which the ion exchanger is completely exhausted and must be regenerated or replaced. In order to enhance the extent of column utilization, it is always beneficial to get as steep a breakthrough curve (adce).

Effluent volume Figure 2.3.4.1 Schematic representation of breakthrough curve (Source: Inamuddin, 2012)

In Figure 2.3.4.1, Co means the initial influent concentration of ammonium; Cx means the instantaneous effluent concentration of ammonium.

Figure 2.3.4.2 Breakthrough curve showing the outlet concentration (source: Tony C. Jorgensen, 2002)

In Figure 2.3.4.2, it illustrates a normal breakthrough curve at three different flow-rates. A high flow-rate is related with early breakthrough and a gentle breakthrough curve. Low flow-rates may be related with later breakthrough and a narrow breakthrough curve. At low flow-rates, a greater volume of water may be treated until breakthrough occurs.

Page 19: Jiali Wang + Kenchouw Wu March 2015 - Oasen

11

3. Methods and materials

For this project, a column set-up was designed and two kinds of materials were chosen for the experiments.

3.1 Set-up To determine the breakthrough capacity of Lewatit and zeolite, a four-column set-up was designed to perform the experiments. The conditions were that the feed water (RO permeate) had an ammonium concentration around 0.1 mg and average temperature of 12oC. The ammonium concentration of effluent was not allowed more than 0.03 mg/L which was considered as a breakthrough point. The schematic overview of the set-up is presented in Figure 3.1.1.

Figure 3.1.1: Schematic overview of the set-up

Specifications of the pilot column setup Number of columns: 4, diaphanous PVC 4 columns for ion exchange beds Column height: 1 m, Inner diameter: 34 mm Filter plates holes: 0.4 mm Taps at the top and bottom of the columns Feed water: RO permeate

Direction of flow: inflow and outflow Sampling points and codes Column 1: influent = XKMKOX01A effluent= XKMKOX01Z Column 2: influent = XKMKOX02A effluent= XKMKOX02Z Column 3: influent = XKMKOX03A effluent= XKMKOX03Z Column 4: influent = XKMKOX04A effluent= XKMKOX04Z The feed water flows through the gate valve followed by the column and out to drain. The selected resin/zeolite should be placed in the column with a designed height for testing. Filter plates are at the top and bottom of the columns. To prevent the material flow out of the columns, the filter stone (3 cm height) is put at the bottom of

Page 20: Jiali Wang + Kenchouw Wu March 2015 - Oasen

12

the column and continued with three layers of sand filter (h=3,3,5cm and size range of 1.0-2.0, 0.8-1.25,0.4-0.8 mm ) on the top of each other. Before running the column, water flows upward through the bed for 5 minutes, causing the bed expansion. In this manner, the smaller beads will be brought to the top and the larger bead to the bottom. This provides a better distribution. Another purpose for doing this is to get air and dirt particles out of the column.

3.2 Materials For the ion-exchange, both resin and zeolite are used. The synthetic ion exchange resin, Lewatit S2568H is a cation exchange resin in the hydrogen form with functional group sulfonic acid provided by Lanxess. Zeolite is in the form of natural clinoptilolite received from Zeolite Products. The color of the zeolite is yellow and green. The chosen size for zeolite is 0.3-1.0 mm and 1.0-2.5 mm. The particle size of resin has a mean bead size of 0.67mm (+/-0.05). For more information about the material, it is to be found in Appendix.

3.3 Measurement methods The ammonium analyses were performed by spectrophotometer Hach-Lang DR 2800 using Hach-Lang cuvettes LCK 304. The detection range of ammonium concentration is from 0.02 to 2.5 mg/L. One of the columns can be connected to analyzer Applikon Colorimeter from which more continuous data will be obtained. The limit of detection for ammonium is 0.01-1.00 mg/L. For the validation of equipments samples were analyzed by the Vitens Drinking water Laboratories.

3.4 The validation of spectrophotometer Hach-Lang DR 2800 To calibrate the spectrophotometer Hach-Lang DR 2800, samples were measured under different conditions and also sent to the Vitens lab to for comparison. One measurement was done by spectrophotometer Hach-Lang DR 2800. The sample was tested twice at different time to see if the equipment works properly. One was tested after a reaction time of 15 minutes. Another one was tested after 30 minutes. And from the manual of the tester, the final absorbance is reached after a reaction time of 15 min and then remains constant for a further 15 min. Therefore, one was tested after a reaction time of 15 minutes. Another one was tested after 30 minutes. If it works well, the ammonium concentration of both being measured should be the same. The other measurement was done by Vitens Laboratories to see if the results matched with each other. (see Table 3.4.1 in Appendix C and Figure 3.4.1)

Figure 3.4.1: 5 cm bed height Lewatit S2568H with flow rate of 12L/h, about 0.1 mg/L NH4

+ feed water measured by Spectrophotometer Hach-Lang DR 2800 and Vitens lab

-0,02

0

0,02

0,04

0,06

0,08

0,1

0,12

0 10 20 30 40 50

NH

4 c

on

cen

trat

ion

(m

g/L)

Time (h)

Column 2 5cm Lewatit S2568H

R.T t=15min

R.T t=30min

t=15min

t=30min

Vitens lab data

Page 21: Jiali Wang + Kenchouw Wu March 2015 - Oasen

13

From the data, it can be seen there was a big difference between the two measurements at different time. The reason might be the sample was not kept at 20 °C according to the manual of Hach-Lang DR 2800. To find out the influence of temperature, new measurement was done with one of the samples kept at room temperature. The result shows the accuracy of measurement is strongly depended on temperature. The measured results from Vitens Laboratories matched better with the results measured by spectrometer when the samples kept at room temperature. In case of not working at the right recommended temperature an incorrect result may be obtained. Therefore it is recommended to keep samples in a water bath at 20 °C before measuring. Sample in water bath The permeate samples were kept in the water bath at a constant temperature of 20 ºC. The measuring results were obtained as follows in table 3.4.2:

t=15 min t=20 min t=25 min t=30 min

NH4+ (mg/L) 0.116 0.123 0.125 0.125

NH4+ (mg/L) 0.108 0.112 0.112 0.114

NH4+ (mg/L) 0.115 0.12 0.118 0.12

Table 3.4.2: permeate measured by Spectrophotometer Hach-Lang DR 2800 The spectrometer provides now much more stable measuring results than before. The results were quite stable at t=20 min. Therefore, the ammonium concentration will be recorded after a reaction time of 20 minutes.

3.5 The validation of ammonium analyzer Applikon Colorimeter In order to examine the accuracy of ammonium analyzer Applikon Colorimeter, some samples were taken for Vitens Laboratories. At the same time, two samples were respectively taken from column 4 for lab test every hour. The ammonium analyzer Applikon Colorimeter measured automatically the ammonium concentration of effluent every 5 minutes.

Figure 3.5.2 Comparison of Vitens and Applikon Colorimeter data from column 4 (5 cm bed height Lewatit S2568H with flow rate of 12L/h, about 0.1 mg/L NH4

+ feed water)

0

0,01

0,02

0,03

0,04

0,05

0,06

0,07

0,08

0,09

0,1

0 100 200 300 400 500 600 700

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Comparison of Vitens and Applikon Colorimeter

Vitens

Applikon Colorimeter

Page 22: Jiali Wang + Kenchouw Wu March 2015 - Oasen

14

Conclusion According to (Table 3.5.1 and Table 3.5.2 in Appendix D), there were 6 times that the lab data didn’t match with the Applikon Colorimeter data (The red shows lab data in table 2). However, the data in blue color that were just taken after a few minutes matched better with the one in red. This appearance was probably caused by the measuring process of analyzer which analyzed samples every 5 minutes. The biggest difference in measuring results was at 10:45 15th January 2015. It might be regarded as the error of ammonium analyzer Applikon Colorimeter, because the ammonium concentration was zero at 10:35 and 0.076 mg/L at 10:55, which totally didn’t make any sense. Based on the figure 3.5.2, the results obtained by analyzer Applikon Colorimeter were different from those by Vitens Laboratories, when the concentration of ammonium was low in effluent. The difference might due to the limit of detection in Vitens Laboratories for ammonium. When the concentration of ammonium was high in effluent, the results of the two measurements were almost the same. Therefore, the result of ammonium analyzer Applikon Colorimeter is reliable.

3.6 The validation of ammonium dosing pump Dosing ammonium to the RO permeate was attempted to get a higher ammonium concentration in influent in order to obtain a breakthrough curve in a short time. The validation of ammonium dosing pump was done by comparing the results of different experiment set-ups. For the sake of dosing ammonium concentration, it was divided into several steps. At first, it was required to figure out the size of tubes and their flow rate. A 10 ml measuring column and a timer were used. The record shows in table 3.6.1. Table 3.6.1.Calibration of pump

Rotating speed (rpm)

Flow rate of tube 1 (mL/min)

Flow rate of tube 2 (mL/min)

Flow rate of tube 3 (mL/min)

Flow rate of tube 4 (mL/min)

100 4.2 4.4 4.2 4.3

50 2.0 2.0 2.0 2.2

According to the measured results above, the diameter of tubes should be 0.76 mm which provides flow rate of 4.2 mL/min at 100 rpm and 2.1 mL/min at 50 rpm. However, the actual flow rate is depended on how the pump, tube and solution tank are placed. 3.6.1 Experiment set-up Experiment 1 The second step was to calculate the amount of required dosing ammonium concentration. The required ammonium dosing concentration to reach an influent concentration of 40 mg/L NH4

+ is calculated as follows: Condition: Pump: 100rpm=4.20 mL/min =0.252 L/h Flow rate of feed water: 12L/h Ammonium concentration of feed water: 0.1mg/L Dosing NH4

+ concentration: X

40mg

L*12.252

L

h=490.08

mg

h

0.252L

h* X

mg

L + 12

L

h* 0.1

mg

L=490.08

mg

h

X=1940mg

L=1.94g/L

NH4+ occupies 34% in ammonia chloride.

NH4Cl =1.94g/L /34%=5.71 g/L. The next step was to check the accuracy of dosing ammonium concentration.

Page 23: Jiali Wang + Kenchouw Wu March 2015 - Oasen

15

In the next experiments, an ammonium dosing solution was made using the same method to get an effluent of 10 mg/L. Experiment 2 Tried to make a better mixing; a few joints were connected with each other (figure 3.6.2). Experiment 3 The one way direction valve was taken off that the tube was directly connected with the tube of feed water (see figure 3.6.3).

Figure 3.6.1 Experiment 1 Figure 3.6.2: Experiment 2 Figure 3.6.3 Experiment 3 Results Experiment 1 Instead of 5.71 g/L NH4Cl, 1.94g/L NH4Cl was prepared by mistaking the mass of NH4Cl the same as that of NH4

+. In this case, dosing NH4+ together with RO permeate should give 13.7 mg/L as influent ammonium concentration. The sample of influent was taken and diluted 20 times. The results was 0.454 mg/L. But it should be 0.685 mg/L. Experiment 2 Experiment 3

No. NH4+

(mg/L)

No. NH4

+ (mg/L)

1 5.55 1 8.60

2 3.65 2 7.70

3 3.52 3 8.79

4 3.67 4 9.51

5 6.04 5 9.76

6 9.37

7 8.28

Experiment 2: Average=4.486 mg/L Minimum=3.52 mg/L Maximum=6.04 mg/L STD=5.84 Experiment 3: Average=8.96 mg/L Minimum=7.70 mg/L Maximum=9.76 mg/L STD=2.86 Conclusion/Discussion Due to the measuring range of ammonium analyzer Applikon Colorimeter is from 0 to 1 mg/L, which means it could not provide a complete breakthrough curve. As the ammonium concentration was so high, the ammonium analyzer Applikon Colorimeter might just record the beginning part of the curve. From the results, it can be concluded the tube without one way direction valve gave the most stable ammonium concentration in comparison with other methods. This method might provide a better mixing and more continuous water flow. To improve the experiment setup, it is recommended to use a tube with a bigger diameter.

Page 24: Jiali Wang + Kenchouw Wu March 2015 - Oasen

16

Page 25: Jiali Wang + Kenchouw Wu March 2015 - Oasen

17

4. Results

The main purpose of this research is to design an ion exchange column for the ammonium removal of feed water (RO permeate). Therefore, the optimum volumetric flow rate should be determined during the experiments over a range of choices which would provide a maximum breakthrough capacity. Since there was a limitation of time, it would take too long to determine the breakthrough capacity at a high bed height. It’s easier to find the relation between the bed height and the breakthrough capacity. A complete list of results can be found in the measuring results in Appendix E.

4.1 The performance of 10 and 20 cm Lewatit S2568H For each flow rate the breakthrough capacity was compared at the same bed height. Also, the performance of different bed height was compared at the same flow rate. The overview of the results is presented in Table 4.1.1 and Figure 4.1.1.

Bed height (cm)

Flow rate (L/h)

Surface loading (m/s)

Average permeate concentration (NH4 mg/L)

Breakthrough capacity (mg/L)

Breakthrough capacity (mg/g)

Breakthrough time (h)

10 40 441 0.136 1399 1.89 26

10 60 661 0.129 1608 2.17 22

10 80 881 0.126 1079 1.46 12

10 100 1101 0.125 1134 1.53 10

20 12 66 0.136 1448 1.96 1833

20 40 220 0.14 1784 2.41 62

20 60 330 0.142 1525 2.06 37

20 80 441 0.136 1487 2.01 30

20 100 551 0.132 1784 2.41 27

Table 4.1.1 Breakthrough capacity of Lewatit S2568H at different bed heights and flow rates

Figure 4.1.1 Breakthrough capacity of Lewatit S2568H at different bed heights and flow rates

0,00

0,50

1,00

1,50

2,00

2,50

3,00

0 20 40 60 80 100 120

Bre

akth

rou

gh c

apac

ity

(mg/

g)

Flow rate (L/h)

Breakthrough capacity of Lewatit S2568H

10 cm resin

20 cm resin

Page 26: Jiali Wang + Kenchouw Wu March 2015 - Oasen

18

The breakthrough capacity is calculated as follows, in the following example:

The area beneath the curve is calculated by integrating the equation of the best fit curve as following:

y = 1E-15x4 - 3E-12x3 + 4E-09x2 - 2E-06x + 0.0075

∫ y2658

0= 1E-15/5x5 - 3E-12/4x4 + 4E-09/3x3 - 2E-06/2x2 + 0.0075x=27

Average concentration of feed water=0.132 mg/L Breakthrough capacity=0.132*2658-27=324 mg 324 mg/0.18 L=1784 mg/L =2.41 mg/g It was expected the trend of breakthrough capacity over a range of flow rates would be similar at different bed height. Unfortunately, the results from the measurements showed differently. Figure 4.1 shows that the optimum breakthrough capacity was at flow rate of 60 L/h in a resin column with bed height of 10 cm, while in a resin column with bed height of 20 cm the optimum breakthrough capacity was at flow rate of 40 L/h or 100 L/h. If 10 cm resin bed was compared to 20 cm resin bed, it shows that the capacity of 20 cm resin bed is getting bigger as the flow rate increases above 60L/h, while the performance of 10 cm resin bed didn’t demonstrate the similar trend. At flow rate of 60L/h, both resin columns with different bed height have almost the same breakthrough capacity. If two different bed heights of resin columns were compared though, it can be seen that the capacity of resin increased with 38% at flow rate of 80L/h and 57% at flow rate of 100 L/h, when the bed height was increased from 10 cm to 20 cm. This indicates that the breakthrough capacity is related to the bed height. Whether the increasing rate of capacity is proportional to the bed height cannot be told though.

y = 1E-15x4 - 3E-12x3 + 4E-09x2 - 2E-06x + 0,0075

0

0,005

0,01

0,015

0,02

0,025

0,03

0,035

0,04

0,045

0,05

0 500 1000 1500 2000 2500 3000 3500

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 20cm Lewatit S2568H with 100L/h permeate water

20cm resin 100L/h

Breakthrough point

Page 27: Jiali Wang + Kenchouw Wu March 2015 - Oasen

19

Figure 4.1.2: Breakthrough curve of 20 cm Lewatit S2568H with different flow rte measured by ammonium analyzer Applikon Colorimeter and Hach Lang spectrometer DR 2800 (flow rate of 12L/h)

Figure 4.1.3:Breakthrough curve of 10 cm Lewatit S2568H with different flow rate measured by ammonium analyzer Applikon Colorimeter

Figure 4.1.2 and Figure 4.1.3 give an overview of the breakthrough curves of resin at different flow rates. The breakthrough curves demonstrate the similar trend. Only at 10 cm bed height, there was an obvious difference between flow rate of 60L/h and the rest. Compared with other flow rates, the flow rate of 40L/h for 20cm bed height might provide the most steep breakthrough curve. Since the complete curve was not obtained, this inference was based on the distribution and characteristics of the data values.

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0 1000 2000 3000 4000 5000 6000

NH

4 c

on

cen

trat

ion

(m

g/L)

Effluent volume (L)

Breakthrough curve of 20cm Lewatit S2568H

20cm resin 60L/h

20cm resin 40L/h

20cm resin 80L/h

20cm resin 100L/h

20cm resin 12L/hBreakthrough point

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0 1000 2000 3000 4000 5000 6000

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 10cm Lewatit S2568H

10cm resin 60L/h

10cm resin 100L/h

10cm resin 40L/h

10cm resin 80L/h

Breakthrough point

Page 28: Jiali Wang + Kenchouw Wu March 2015 - Oasen

20

4.2 Comparison between Lewatit S2568H and clinoptilolite

Figure 4.1.4 Breakthrough curve of 20 cm Lewatit S2568H measured by ammonium analyzer Applikon Colorimeter and that of clinoptilolite by Hach Lang spectrometer DR 2800

The chosen particle size range here for the zeolite is 0.3-1.0 mm. Figure 4.1.4 shows that the performance of resin is much better than that of zeolite. The zeolite reached the breakthrough at effluent volume of around 150 L, while the resin at effluent volume of around 2500 L. This is probably 17 times better. The breakthrough times for zeolite were 1.7 h and 1.3 h and for resins were 30 h and 26 h at flow rate 80 L/h and 100 L/h respectively.

4.3Comparison between clinoptilolite with different particle size

zeolite 1.0-2.5mm

duration (h) 2

NH4 (mg/L) 0.02

zeolite 0.3-1.0mm

duration (h) 17 23 42 45 64 66 70

NH4 (mg/L) 0.012 0.014 0.018 0.013 0.017 0.013 0.012 Table 4.3.1 Performance of zeolites in different particle size at bed height of 30 cm, flow rate of 12L/h (measured by Hach Lang spectrometer DR 2800

Two kind of zeolite with different particle sizes were used. One has a range between 0.3-1.0 mm; the other has a range between 1.0-2.5 mm. As expected, it is advantageous to use smaller particle size grading. (see paragraph 2.3.2). In a condition where 30 cm bed height zeolite was at flow rate of 12 L/h, the zeolite of big particle size reached 0.02 mg NH4

+ in effluent after 2 hours. For zeolite of small particle size, the ammonium concentration in effluent was under measuring range even after 70 hours. (see Table 4.3.1)

0

0,01

0,02

0,03

0,04

0,05

0,06

0,07

0,08

0,09

0 1000 2000 3000 4000

NH

4 c

nce

ntr

atio

n (

mg/

L)

Effluent volume(L)

Breakthrough curve of 20cm clinoptilolite and Lewatit S2568H

20cm resin 80L/h

20cm resin 100L/h

20cm zeolite 80L/h

20cm zeolite 100L/h

Page 29: Jiali Wang + Kenchouw Wu March 2015 - Oasen

21

5. Discussion

5.1 Influence of bed height In ion exchange, if the separation factor for the unwanted ion to be removed is greater than 1, the mass transfer zone length or exchange zone will be relatively small in comparison with the column height. (John C. Ctrittenden et al., 2015). This indicates that an increase in bed height for the column at the same flow rate will not change the breakthrough capacity. From the literature, it shows that the NH4

+/H+ separation factor is 1.9. Since the separation factor is greater than 1, it was expected that the breakthrough capacity would remain the same for different bed height. Unfortunately, the results showed differently. Some studies recommend doing column experiments at a reasonable height between 0.6 to 1m. This is probably due to the fact that the feed water would flow downward along with the column walls, which results in less efficient contact with the resin when the bed height is not high enough. From the Figure 4.1.1, it can be seen that the resin with a higher bed height also has a higher breakthrough capacity. But it was expected that the rate of an increase in breakthrough capacity would be lower as the bed height increases. At a certain bed height, the influence of it on breakthrough capacity would be neglected.

5.2 Influence of flow rate Normally, in the case of strong acid resin in dilute solutions, the flow rate of ions arrived on the beads is faster than ions diffuse through the film. As described in paragraph (2.3.2), the distinction between H+ form and NH4

+ form resin will not be obvious. Thus, the breakthrough capacity is expected to be lower at a higher flow rate. If the thickness of the film remains the same, the breakthrough capacity would decrease proportional to the flow rate. In fact, the thickness of the film wouldn’t stay unchanged; it decreases with an increase in flow rate. Therefore, the rate of arrival of ions would be faster. But the loss of breakthrough capacity would be minimized by the thicker flim. This helps to explain why Figure 4.1 shows that the flow rates over a range between 12 and 100L/h do not have significantly impact on the breakthrough capacity of the resin. This also implies that the breakthrough time is long enough for the ion exchange process to happen in the resin. The resin is at equilibrium with the solution.

Figure 5.1 Effect of breakthrough time and flow rate on the breakthrough capacity The Figure 5.1 presents how the relation between breakthrough capacity and flow rate and breakthrough time could look like. At a certain short breakthrough time and high flow rate, the time required for ions diffuse through the film is longer than that for ions to be presented to the resin beads. Thus, the film diffusion begins to take the effect.

Breakthrough time (h)

Flow rate (L)

Breakth

rou

gh cap

acity (mg/g)

Page 30: Jiali Wang + Kenchouw Wu March 2015 - Oasen

22

5.3 Kinetics The figures 4.2 and 4.3 also indicate that the film diffusion is rate controlling. As the ion concentration in the feed water increases, the rate of film diffusion increases and becomes even faster than the rate of particle diffusion. The overall rate of ion exchange process is determined by the particle diffusion. If it is so, the breakthrough capacity would increase proportional to the flow rate. In other word, the film diffusion is rate controlling in the diluted solution. In the experiment condition, the feed water had only ammonium concentration of around 0.1 mg/L. The concentration of other ions should be very low, because the feed water was obtained after the RO membrane process. Therefore, the feed water was a diluted solution, in which the rate of ion exchange process was film diffusion determined.

5.4 Performance of zeolite and resin The resin performed much better than zeolite. This might because the surface of zeolite was much rougher than that of resin. Therefore, there was an increase in thickness of the film and ammonium need more time to diffuse through the surrounding film. Lewatit S 2568H is a cation exchange resin in the hydrogen form. Zeolite is in the form of clinoptilolite with Na+ as counter-ions. Since the size of H+ is smaller than that of Na+, it might easier for H+ to diffuse from the beads to the bulk solution. In the comparison of the previous research done by Ekowati, the results were the same. The resin performed better than zeolite. In her research, no breakthrough of the resin was observed until the experiments were stopped. But when it comes to the run length of the zeolite, the results were not comparable. The run lengths calculated base on the KWR isotherm were 18h and 14h at flow rate 80 L/h and 100 L/h. According to the experiment results, they were 1.7 h and 1.3 h. This might because the bed height was too low to prevent the feed water flows down along with the walls effectively.

5.5 Influence of particle size. Reaction is a function of particle size. As explained in paragraph 2.2.3, the smaller particle size provides a larger surface area. The time an ion needs to travel through the resin bead itself decreases with decreasing particle size. From the experiments, it can be seen that the results were comparable to that found in KWR report. In this report, it’s concluded that ammonium removal is faster with the smaller grains.

5.6 Difficulties of doing pilot experiments The ammonium concentration of feed water was not so stable during the experiments. In the extreme case, the lowest concentration was 0.08 NH4

+ mg/L and the highest concentration was 0.16 NH4+ mg/L. If the experiments

were done at different bed heights, more data would be obtained to help investigate the relation between the bed height and the breakthrough capacity. But, it’s not possible to do due to the time limitation. A higher bed height would require more time to run the experiment. Sometimes, it was not possible to get a complete and reliable breakthrough curve by using Hach Lang spectrometer DR 2800, because the breakthrough point occurred during the night. It was planned to increase the NH4

+ concentration in feed water by doing pump. Unfortunately, it was not succeeding and the mixing problem still has to be dissolved.

Page 31: Jiali Wang + Kenchouw Wu March 2015 - Oasen

23

6. Ion exchange column design calculation

6.1 Introduction For the up-scaling calculation it is required to know how much water is produced. Drinking water treatment plant “De Hooge Boom” in Kamerik is designed to have an average production of 300m3/hour with a peak production of 420m3/hour. From this and other boundary conditions the preliminary design of the membrane filtration step is to have 4 stacks of each a capacity of 120m3/hour. Following the first treatment, every succeeding step in the treatment plant will consist of 4 unit with each a capacity of 120m3/hour (see Appendix F). Based on the results of the experiments, it was found that Lewatit S2568H resin is more effective than clinoptilolite for the removal of ammonium ions from permeate. To design ion exchange columns there are some aspects that should be taken into consideration, such as the volume of resin, the surface area of resin, the height of columns, the number of columns and the pressure drop. The data obtained from small-column (1.0 to 5.0 cm inside diameter) can be scaled up directly to full-scale design if the surface loading rate and empty bed contact time are the same. (John C. Ctrittenden et al., 2015) This rule can be applied to scale-up this design, because the diameter of columns is 3.4 cm. To get the above described parameters, the optimum volumetric flow rate should be determined during the experiments over a range of choices to find out if there is a maximum breakthrough capacity at a certain flow rate. According to John C. Ctrittenden, the minimum bed height used in the industry is 0.75 m, and the maximum 3 m. The maximum bed height is established to prevent the big pressure drop that would affect the stability of the resin. From the results, it can be seen that by increasing the bed height at the same flow rate the breakthrough capacity would be increased. Thus, a higher bed height is preferred but not exceeds the maximum. Based on manufacture’s production information, the minimum bed depth for Lewatit S2568H is 800mm.

6.2 Design calculation Since the experiment results show that the breakthrough capacity was quite stable over a range of flow rate between 12L/h and 100L/h, the following assumptions are made:

- The maximum capacity is all used. - Average breakthrough capacity of 2.17 mg/g (1606 mg/L) at 20 cm bed height is used for calculation for

different bed heights. It is assumed that the breakthrough capacity remains the same. - The ammonium concentration of permeate is 0.14 mg/L.

An example of calculation for the column design In this example a flow rate of 100L/h is taken. Pressure drop Based on the manufacture’s data, the maximum pressure drop for the resin bed is 300kPa. Both of surface loading and bed height have impact on pressure drop through the resin. The relevant information can be found in pressure drop formula sheet (Appendix B) provided by manufacture. The pressure drop of ion exchange resin beds is calculated according the following formula:

Δp [kPa] = h [m] x v [m/h] x FV x FT x FR

h = Resin bed depth [m] v = Linear velocity [m/h] FV = Velocity factor (from diagram 6.1 and Appendix C) FT = Temperature factor (Appendix C) FR = Resin factor (specific pressure drop [kPa x m-2 x h]

Page 32: Jiali Wang + Kenchouw Wu March 2015 - Oasen

24

Diagram 6.1 Velocity factor

FR in this case is 0.8 [kPa x m-2 x h] FT=1.1 Linear velocity/surface loading (m/h)= 100/1000/(π*0.017^2)=110 m/h Maximum resin bed height (m) h= 300/(110*(4*(10^-5)*110^2+0.003*110+0.919)*1.1*0.8)=1.8m

Service flow rate The volume of the bed occupied by the resin:

BV=area × depth=π(0.17dm)2×18dm=1.63L SFR=100L/h×1BV/1.63L=61BV/h

Volume of resin Treated water flow rate=120 m3/h

Total required resin volume=Treated water flow rate

SFR=

120L/h

61 BV/h==2.0 m3

Surface area of resin required

Total required surface area=Resin volume

Resin depth=

2.0 m3

1.8 m=1.1m2

Diameter= (1.1 m2/π)^0.5*2=1.2m Breakthrough time

Approximate breakthrough time= 2.0 m3*1000L

m3*1606mg

L/0.14

mg

L/120000

L

h=186h=7.7days

Cost of material If the exhausted resin is replaced by new resin after each 7.7 days without considering regeneration, the total cost per year would be: Lewatit S2568H= 2.55 euro per Liter

Total cost= =2.55euro

L*2.0 m3*1000

L

m3/(7.7days/365days)=233673 euro

Total produced water per year= 130m3

h*4*24*365=4555200 m3

The cost per m3 water produced would be 233673 euro/4555200 m3 =0.06 euro This price is also for flow rate between 12-100L/h, because the breakthrough capacities are almost the same.

y = 4E-05x2 + 0,003x + 0,919

1

1,1

1,2

1,3

1,4

1,5

1,6

1,7

1,8

20 30 40 50 60 70 80 90 100 110 120

Ve

loci

ty F

acto

r

Flow rate (m/h)

velocity factor of Lewatit S2568H

velocity factor

Page 33: Jiali Wang + Kenchouw Wu March 2015 - Oasen

25

Column height As there is bed expansion during backwashing with considerable risk of resin loss, an extra space is needed. The

bed expansion is about 70% at the flow rate of 12 L and the water temperature is 12℃. The required height for backwashing= 1.8m*70%=1.26 m The minimum column height without considering of the height for resin support and inlet distributor should be: 1.8m+1.26m=2.06 m. An over view of column design

Flow rate (L/h)

Surface loading

(m/h)

Resin bed height

(m)

SFR (BV/h)

Required resin volume

(m3)

Required surface area

(m2)

Diameter

(m)

Break- Through Time

(h)

Break- Through time

(days)

Material cost per year

(euro)

12 13 27 0.5 243 9.1 3.4 23183 966.0 233673

20 22 15 1.4 84 5.4 2.6 8023 334.3 233673

30 33 10 3.4 35 3.6 2.2 3373 140.6 233673

40 44 6.9 6.4 19 2.7 1.9 1785 74.4 233673

50 55 5.1 10.7 11 2.2 1.7 1070 44.6 233673

60 66 4.0 16.6 7 1.8 1.5 693 28.9 233673

70 77 3.2 24.2 5 1.6 1.4 474 19.7 233673

80 88 2.6 34.0 4 1.4 1.3 337 14.0 233673

90 99 2.1 46.4 3 1.2 1.2 247 10.3 233673

100 110 1.8 61.7 2 1.1 1.2 186 7.7 233673

Table 6.1 overview of column design with maximum resin bed height The influence of different surface loadings on the design is presented in table 6.1. The resin bed height above presented the maximum bed height a column can have without exceeding the limited pressure drop. As the surface loading increases, the size of the column and breakthrough time decrease. Although, a smaller column requires replacement or regeneration of resin more frequently, it saves the space and equipment investment and maintenance cost. Recommendation It was noticed that the breakthrough time for each flow rate above is quite long. It is considerable to replace with the new resin after each service run, if the financial aspect is not considered. However, in real life it is always good to have a cost as low as possible while maintaining quality. The material cost of 6 cents per m3 water is a bit too expensive. The ion exchange process with regeneration might be a good solution. The following assumptions are made:

- Bed height is 2m (feasible, a common bed height for ion exchange) - Regeneration cost is maximum 25% of the resin cost

An overview of column design at bed height of 2 m is shown in Table 6.1. Flow rate at 100L/h is not excluded from the calculation table, because its maximum allowed bed height is 1.8 m.The calculation method is the same as before. The material cost per m3 produced water is calculated as follows: For example at flow rate of 90 L/h Material cost per year=

2.55 euro

L*2.42m3*1000

L

m3+2.55euro

L*2.42m3*1000

L

m3*0.25*365days/9.6days= 64596 euro

Material cost per m3 produced water= 64596 euro/4555200 m3=0.014euro

Page 34: Jiali Wang + Kenchouw Wu March 2015 - Oasen

26

flow rate (L/h)

linear velocity (m/h)

Resin Bed Height

(m)

SFR (BV/h)

Required resin volume

(m3)

Required surface area

(m2)

Diameter

(m)

Break- through

time (days)

Material cost per year

(euro)

Material cost per m3 water

(euro)

12 13 2 6.6 18.16 9.1 3.4 72.3 104722 0.023

20 22 2 11.0 10.90 5.4 2.6 43.4 86201 0.019

30 33 2 16.5 7.26 3.6 2.2 28.9 76940 0.017

40 44 2 22.0 5.45 2.7 1.9 21.7 72309 0.016

50 55 2 27.5 4.36 2.2 1.7 17.4 69531 0.015

60 66 2 33.0 3.63 1.8 1.5 14.5 67679 0.0149

70 77 2 38.5 3.11 1.6 1.4 12.4 66356 0.0146

80 88 2 44.1 2.72 1.4 1.3 10.8 65364 0.0143

90 99 2 49.6 2.42 1.2 1.2 9.6 64592 0.0142

Table 6.1 overview of column design with 2m resin bed height From the table, it can be seen that the size of column and material cost decrease as the flow rate (surface loading) decreases. Thus, for a 2 m bed height column, it’s best to operate at a surface loading of 99 m/h. Both equipment cost and material cost would be the lowest. The empty bed contact time is calculated with the formula:

EBCT= H

V

EBCT=empty bed contact time (h) V=surface loading (m/h) H=bed height (m)

The EBCT would be: EBCT= 2m

99m/h=0.02 h= 1.2 minutes

The minimum column height without considering of the height for resin support and inlet distributor would be: 2.0m(1+70%)=3.4 m.

Page 35: Jiali Wang + Kenchouw Wu March 2015 - Oasen

27

7. Conclusion and recommendations for future research

7.1 Conclusion The goal of this research project is to design ion exchange column for the future full scale treatment plant De Hooge Boom in Kamerik. In order to reach this goal the following research questions were asked and needed to be answered.

What is the influence of the surface loading (which is flow rate of feed water on the effectiveness of ammonium removal by ion exchange)? It was expected that the breakthrough capacity would increase as the flow rate increases. However, the results showed differently. The breakthrough curves demonstrated the similar trend at the flow rate between 12L/h and 100L/h. The possible explanation for this phenomenon was discussed in chapter 6. If the thickness of the film remains the same, the breakthrough capacity would be lower at a higher flow rate. In fact, the thickness of the film wouldn’t remain unchanged; it decreases with an increase in flow rate. This results in faster arrival of ions on the beads. But the loss of breakthrough capacity would be minimized or avoided by the thicker film. For the ion exchange column design, the average breakthrough capacity of 2.17 mg/g (1606 mg/L) was used. What is the influence of the bed height of the ion exchange for the effectiveness of ammonium removal? From the results, it can be concluded that the ion exchanger with a higher bed height also has a higher breakthrough capacity. This is because the column walls are every smooth in comparison with the bed so that the feed water would flow downward along with the column walls. The feed water would have less contact with the ion exchanger. But it was expected that the rate of an increase in breakthrough capacity would be lower as the bed height increases. At a certain bed height, the influence of it on breakthrough capacity would be neglected. What would the design in the future treatment plant look like? Based on the experiment results and calculation, the ion exchange is design as follows: Number of vessels: 4 – each with a capacity of 120m3/h Bed height: 2m Column height (without considering of the height for resin support and inlet distributor)=3.4m Surface loading: 99m/h EBCT: 1.2 minutes Breakthrough time: 10 days Material cost of resin per m3 water produced: €0.014

Page 36: Jiali Wang + Kenchouw Wu March 2015 - Oasen

28

7.2 Main uncertainties in the research and design One of the main uncertainties would be the relation between the flow rate and the breakthrough capacity. From the experiment results, the breakthrough capacities were quite similar between 12L/h and 100L/h. But, what will happen with the breakthrough capacity at a higher flow rate still need to be tested through experiments. Another uncertainty was the influence of bed height on the breakthrough capacity and to what degree.

7.3 Recommendations for future research It’s recommended to do experiments at higher bed heights, for example at 80 cm. The effect of less contact time with the ion exchanger that caused by the fact that water flows down along with the column walls would be minimized in this manner. Since the ammonium concentration of feed water was not constant, it’s better to measure the concentration more frequently. Higher flow rate can be tried in the future research to see how it will affect the breakthrough capacity. It is also interesting to dose an ammonium concentration to the feed water to see how NH4

+ concentration related to the breakthrough capacity at the same flow rate.

Page 37: Jiali Wang + Kenchouw Wu March 2015 - Oasen

29

Reference

B.A.Bolto and L.Pawlowski (1987) wastewater treatment by ion exchange., E.& F. N. Spon

George J. Crits (2012) Crits Notes on Water and Ion Exchange., Chemical Publishing

Helfferich,F. (1961) Ion exchange, McGraw-Hill, pp250-319.

Inamuddin Mohammad Luqman (2012) Ion exchange technology I theory and materials, Springer, London. pp.22.

John C. Ctrittenden, R.R.Trussell, D.W.Hand, K.J.Howe, G.Tchobanoglous (2015) John Wiley & Sons, Inc, Water treatment, principles and design. MWH. Second edition. P.1406-1426.

Kiwa N.V. (2005) Ammonium removal in drinking water using natural zeolite Kunin R (1951) Ion exchange. Ind Eng Chem 43:102–108 Langwaldt, J. R. (2008) Ammonium Removal From Water by Eight Natural Zeolites: A Comparative Study. Separation Science and Technology, 43, 2166 - 2182. Rohm and Haas (2008) Ion exchange introduction R.R.Harries. (1988) The role of pH in ion exchange kinetics, Ion Exchange for Industry, Nottingham NG11 OEE, UK, pp.314-325 Schmidt, W (2008) http://www.mpimuelheim.mpg.de/kofo/institut/arbeitsbereiche/schmidt/zeolites_ee.html. Tony C. Jorgensen (2002) Removal of ammonia from wastewater by ion exchange in the presence of organic compounds. Master of Engineering, University of Canterbury. T.V.Arden., F.R.I.C.,M.I.M.M., P.A.I.W.E (1968) Water purification by ion exchange., Plenum Press Yuli Ekowati (2014) From RO permeate to an impeccable drinking water and biologically stable water. Oasen&UNESCO-IHE Institute for Water Education. Yvonne Mikkers (2009) Regeneration of zeolites used for ammonium removal from anaerobic groundwater. Oasen&Master of Science in civil engineering, Delft University of Technology.

Page 38: Jiali Wang + Kenchouw Wu March 2015 - Oasen

30

Appendix A: Drinking water quality standards The following environmental quality standards are target values which relate to surface water used for the preparation of drinking water.

Parameter Unit Standard

acidity pH 7,0 – 8,5

suspended solids mg/l 25

Conductivity electricity mS/m at 20°C 100

Odor dilution factor at 20 ° C 3

chloride mg/l Cl 150

sulphate mg/l SO4 100

fluoride mg/l F 0,7

ammonium mg/l N 0,2

Organic nitrogen mg/l N 1

nitrate mg/l NO3 25

dissolved oxygen mg/l O2 > 6

Chemical oxygen demand mg/l O2 30

Biochemical oxygen demand mg/l O2 3

sodium mg/l Na 90

Iron resolved mg/l Fe 0,1

manganese μg/l Mn 50

buyer μg/l Cu 20

zinc μg/l Zn 200

drill μg/l B 1000

arsenic μg/l As 10

cadmium μg/l Cd 1

Chromium (total) μg/l Cr 20

lead μg/l Pb 30

selenium μg/l Se 10

mercury μg/l Hg 0,3

barium μg/l Ba 100

cyanide μg/l CN 50

Surface-active substances which react with methyleenblau μg/l 200

Water vapor volatile phenols μg/l C6H5OH 5

mineral oil μg/l 50

Polycyclic aromatic hydrocarbons μg/l 0,2

Human toxicological relevant plant protection products, biocides, and their relevant degradation products (sum)

μg/l 0,5

Pesticides, biocides and their relevant degradation products per individual substance

μg/l 0,1

Choline-esterase inhibitors, μg/l 1,0

Coliform bacteria (total) number per 100 ml

50

Page 39: Jiali Wang + Kenchouw Wu March 2015 - Oasen

31

Parameter Unit Standard

Thermo-tolerant coliform bacteria number per 100 ml

20

fecal streptococce number per 100 ml

20

algae Biomass μg/l chlorofyl-a 100

Table 1. Environmental quality standards with respect to surface water used for the preparation of drinking water

Page 40: Jiali Wang + Kenchouw Wu March 2015 - Oasen

32

Appendix B: Schematic drawing Set-up by Yvonne Mikkers

Page 41: Jiali Wang + Kenchouw Wu March 2015 - Oasen

33

Appendix C: Material data sheet

Page 42: Jiali Wang + Kenchouw Wu March 2015 - Oasen

34

PRODUCT INFORMATION

LEWATIT® S 2568 H

Lewatit® S 2568 H is a food grade, macroporous, monodisperse, strongly acidic cation exchange resin

based on a styrene-divinylbenzene copolymer. Lewatit

® S 2568 H is especially applicable for:

» the decationization of solutions of organic products, e.g. sugar beet, sugar cane, starch sugar, glycerine,

gelatine, whey and food acids etc.

» the extraction of amino acids, e.g. lysine » mixed bed polishing

Lewatit

® S 2568 H is adding special features to the resin bed:

» high exchange flow rates during regeneration and loading » a good utilization of the capacity, low rinse water demand » a homogeneous throughput of regenerants, water and solutions; therefore an homogeneous working zone » a nearly linear pressure drop gradient for the whole bed depth; therefore an operation with higher bed

depth possible

» a good separation behaviour of the components in a mixed bed application

If using Lewatit

® S 2568 H to treat potable water and the aqueous solutions listed above, special care should

be given to the initial cycles of the new resin. Please refer to the recommended start-up conditions available

on request.

The special properties of this product can only be fully utilized if the technology and process used correspond

to the current state-of-the-art. Further advice in this matter can be obtained from Lanxess, Business Unit

Liquid Purification Technologies (LPT). This document contains important information

and must be read in its entirety.

Edition: 2014-05-22 1/5 Previous Edition: 2014-01-16

Page 43: Jiali Wang + Kenchouw Wu March 2015 - Oasen

35

PRODUCT INFORMATION

LEWATIT® S 2568 H

General Description

Ionic form as shipped H+

Functional group Sulfonic acid

Matrix Crosslinked polystyrene

Structure Macroporous

Appearance Beige-grey, opaque

Specified Data metric units

Uniformity Coefficient max. 1.1

Mean bead size mm 0.67 (+/- 0.05)

Total capacity min. eq/l 1.6

Physical and Chemical Properties metric units

Bulk density (+/- 5 %) g/l 740 Density approx. g/ml 1.18

Water retention wt. % 54 - 60

Volume change H+ --> Na

+ max. vol. % - 8

Stability at pH-range 0 - 14

Stability temperature range °C -20 - +120 Storability of the product max. years 2

Storability temperature range °C -20 - +40

This document contains important information

and must be read in its entirety.

Edition: 2014-05-22 2/5 Previous Edition: 2014-01-16

Page 44: Jiali Wang + Kenchouw Wu March 2015 - Oasen

36

PRODUCT INFORMATION

LEWATIT® S 2568 H

Recommended Operating Conditions* metric units

OPERATION

Operating temperature max. °C 120

Operating pH-range 0 - 14

Bed depth min. mm 800

Specific pressure drop (15 °C) approx. kPa*h/m2 0.8

Pressure drop max. kPa 300

REGENERATION,

COUNTER-CURRENT

Regenerant type HCl H2SO4 NaCl

Regenerant quantity approx. g/l HCl 60 H2SO4 100 NaCl 100

Regenerant concentration wt. % HCl 4 - 6 H2SO4 1.5 / 3** NaCl 8 - 10

Linear velocity approx. m/h HCl 5 H2SO4 10 - 20 NaCl 5

Linear velocity rinsing approx. m/h 5 Rinse water requirement slow / fast approx. BV 2.5

REGENERATION, CO-

CURRENT

Regenerant type HCl H2SO4 NaCl

Regenerant quantity approx. g/l HCl 100 H2SO4 150 NaCl 200

Regenerant concentration approx. wt. % HCl 4 - 6 H2SO4 1.5 / 3** NaCl 8 - 10

Linear velocity backwash (20 °C) approx. m/h 10 - 12 Linear velocity rinsing approx. m/h 5 Bed expansion (20 °C, per m/h) approx. vol. % 4 Freeboard backwash vol. % 60

(extern / intern) * The recommended operating conditions refer to the use of the product under normal operating

conditions. It is based on tests in pilot plants and data obtained from industrial applications. However, This document contains important information

and must be read in its entirety.

Edition: 2014-05-22 3/5 Previous Edition: 2014-01-16

Page 45: Jiali Wang + Kenchouw Wu March 2015 - Oasen

37

PRODUCT INFORMATION

LEWATIT® S 2568 H

additional data are needed to calculate the resin volumes required for ion exchange units. These data are

to be found in our Technical Information Sheets. ** Regeneration progressive This document contains important information

and must be read in its entirety.

Edition: 2014-05-22 4/5 Previous Edition: 2014-01-16

Page 46: Jiali Wang + Kenchouw Wu March 2015 - Oasen

38

PRODUCT INFORMATION

LEWATIT® S 2568 H

Additional Information & Regulations Safety precautions Strong oxidants, e.g. nitric acid, can cause violent reactions if they come into contact with ion exchange

resins. Toxicity The safety data sheet must be observed. It contains additional data on product description, transport,

storage, handling, safety and ecology. Disposal In the European Community Ion exchange resins have to be disposed, according to the European waste

nomenclature which can be accessed on the internet-site of the European Union. Storage It is recommended to store ion exchange resins at temperatures above the freezing point of water under

roof in dry conditions without exposure to direct sunlight. If resin should become frozen, it should not be

mechanically handled and left to thaw out gradually at ambient temperature. It must be completely thawed

before handling or use. No attempt should be made to accelerate the thawing process. This information and our technical advice – whether verbal, in writing or by way of trials –

are given in good faith but without warranty, and this also applies where proprietary rights

of third parties are involved. Our advice does not release you from the obligation to check

its validity and to test our products as to their suitability for the intended processes and

uses. The application, use and processing of our products and the products manufactured

by you on the basis of our technical advice are beyond our control and, therefore, entirely

your own responsibility. Our products are sold in accordance with the current version of

our General Conditions of Sale and Delivery.

LANXESS Deutschland GmbH BU LPT D-51369 Leverkusen www.lewatit.com www.lanxess.com

Edition: 2014-05-22 5/5

Page 47: Jiali Wang + Kenchouw Wu March 2015 - Oasen

39

Appendix D: The results of validation of equipment’s Column 2 Lewatit S2568H with bed height of 5cm

Datum :13-01-2015

Time Taking T=15 min NH4+ (mg/L) T=30 min NH4

+ (mg/L) Temperature (ºC) Lab data NH4+ (mg/L)

11:45 0.011 0.029 R.T

11:45 -0.006 0.001

12:45 0.012 0.023 R.T 0.0045

12:45 -0.003 0.016

13:45 0.027 0.031 R.T 0.0011

13:45 0.004 0.018

14:45 0.013 0.015 R.T 0.0016

14:45 -0.002 0.014

15:25 0.005 0.014 R.T 0.0031

15:25 -0.005 0.01

Datum :14-01-2015

8:45 0.008 0.032 R.T 0.016

8:45 -0.004 0.02

9:45 0.023 0.034 R.T 0.025

9:45 0.007 0.032

10:45 0.025 0.052 R.T 0.028

10:45 0.010 0.041

13:45 0.040 0.053 R.T 0.034

13:45 0.038 0.049

Datum :15-01-2015

9:45 0.073 0.086 R.T 0.072

9:45 0.044 0.074

10:45 0.071 0.090 R.T 0.075

10:45 0.043 0.079

11:45 0.073 0.090 R.T 0.078

11:45 0.044 0.083

12:45 0.074 0.096 R.T 0.074

12:45 0.041 0.078

Negative value: under measuring range (0.02 - 2.5 mg/L ammonium) R.T= Room temperature Table 3.4.1: (5 cm bed height Lewatit S2568H with flow rate of 12L/h, about 0.1 mg/L NH4

+ feed water measured by Spectrophotometer Hach-Lang DR 2800 and Vitens lab)

Page 48: Jiali Wang + Kenchouw Wu March 2015 - Oasen

40

Date time Parameter laboratory Validated Value

13/1/2015 12:45 Ammonium - mg/l NH4 - 0271 Vitens Yes 0.006

13/1/2015 13:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0.009

13/1/2015 14:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0.011

13/1/2015 15:25 Ammonium - mg/l NH4 - 0271 Vitens Yes

0.011

14/1/2015 08:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,035

14/1/2015 09:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,036

14/1/2015 10:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,041

14/1/2015 11:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0.003

14/1/2015 12:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,046

14/1/2015 13:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,042

15/1/2015 09:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,069

15/1/2015 10:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,073

15/1/2015 11:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,073

15/1/2015 12:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,073

15/1/2015 13:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,073

15/1/2015 14:45 Ammonium - mg/l NH4 - 0271 Vitens Yes

0,076

Table 3.5.1: Data of column 4 (5 cm bed height Lewatit S2568H with flow rate of 12L/h, about 0.1 mg/L NH4+ feed water measured by

Spectrophotometer Hach-Lang DR 2800 and Vitens lab)

Page 49: Jiali Wang + Kenchouw Wu March 2015 - Oasen

41

Date and time Status Value

2015/1/13 12:45 OK 0.011

2015/1/13 13:45 OK 0.016

2015/1/13 14:45 OK 0.011

2015/1/13 15:25 OK 0.019

2015/1/14 8:45 OK 0.033

2015/1/14 9:45 OK 0.025 0.04

2015/1/14 10:45 OK 0.022 0.04

2015/1/14 10:50

OK 0.04

2015/1/14 11:45 OK 0.042 <0.03

2015/1/14 12:45 OK 0.037 0.05

2015/1/14 13:45 OK 0.041

2015/1/15 10:35 OK 0

2015/1/15 10:45 OK 0.003 0.07

2015/1/15 10:55 OK 0.076

2015/1/15 10:55 OK 0.076

2015/1/15 11:45 OK 0.068

2015/1/15 12:45 OK 0.07

2015/1/15 13:45 OK 0.071

2015/1/15 14:45 OK 0.072 0.08

2015/1/15 14:50 OK 0.08

Table 3.5.2:Data of column 4 (5 cm bed height Lewatit S2568H with flow rate of 12L/h, about 0.1 mg/L NH4+ feed water measured

ammonium analyzer Applikon Colorimeter and shows in black and blue.

Page 50: Jiali Wang + Kenchouw Wu March 2015 - Oasen

42

Appendix E: Measuring reports 5 cm Lewatit S2568H Condition: Feed water = RO permeate with probably 0.1 mg/L ammonium concentration Temperature of feed water= 12 0C Flow rate =12L/h

Graph 1: Experiment 1 and experiment 2 (5 cm resin with flow rate of 12L/h measured by analyzer Applikon Colorimeter)

The ion exchange experiments with resin bed height of 5cm were done twice. Both gave the similar results. The breakthrough curves were expected to be constant at the beginning and sharp later on. In fact, the ammonium concentration already started to increase when the experiment began. A lot of peaks and dips can be recognized. The value of zero ammonium in effluent seems very strange. It looks like the resin was regenerated during the experiment. Thus, it could be considered as measuring error. Despite of these inconsistencies a general trend in ammonium concentration in effluent can be recognized. From the graphics, it can be seen the ammonium concentration was increasing linearly with the effluent volume. A reason for this could be the bed height is too short or the flow rate is too high.

0

0,01

0,02

0,03

0,04

0,05

0,06

0,07

0,08

0,09

0,1

0 500 1000 1500 2000

NH

4 c

on

cen

trat

ion

(m

g/L)

Time(minutes)

Breakthrough curve

Exp2 NH4(mg/L)

Exp1.NH4(mg/L)

breakthrough

Page 51: Jiali Wang + Kenchouw Wu March 2015 - Oasen

43

1 cm Clinoptilolite (1.0-2.5 mm) Condition: Feed water = RO permeate with probably 0.1 mg/L ammonium concentration Temperature of feed water= 12 0C Flow rate =12L/h

Graph 2: 1cm zeolite with flow rate of 12L/h measured by analyzer Applikon Colorimeter From Graph 2, the beginning concentration of ammonium was 0.07 mg/L. As the permeate inflow was 0.1 mg/L, it could be considered that ion exchange was not complete. That is to say, at the begging, it reached at the breakthrough point. The bed height of zeolite was only 0.01m that was the main reason of 0.07 mg/L ammonium concentration at the start point. Specifically, the graph of ammonium concentration fluctuated between 0.06 mg/L and 0.1 mg/L. Some moment even reached at 0 mg/L. The above breakthrough curve was absolutely different as the usual one. Reason: Due to the shearing strength, the flow rate was different among the middle and the wall of the column. Specifically, the velocity of middle equaled to the inflow rate and should be much higher than the velocity of the column’s wall. But in fact, the bed height of zeolie was only 1cm. The bed which contains zeolite has very rough surface. In comparison with that, the column wall is very smooth. Because of this, the water flow rate should be the highest along with the wall and slowest in the zeolite. In case of 1 cm of zeolite bed, water might go through the column too fast without enough contact time with zeolite to perform ion exchange. Therefore, the effluent already reached breakthrough at the beginning.

0

0,01

0,02

0,03

0,04

0,05

0,06

0,07

0,08

0,09

0,1

0 1000 2000 3000 4000 5000

NH

4 c

on

cen

trat

ion

(m

g/L)

time (minutes)

Breakthrough curve of 1 cm clinoptilolite with 12L/h permeate water

NH4 concentration

Breakthrough

Page 52: Jiali Wang + Kenchouw Wu March 2015 - Oasen

44

10 cm Clinoptilolite (1.0-2.5 mm) Condition: Feed water = RO permeate with probably 0.1 mg/L ammonium concentration Temperature of feed water= 12 0C Flow rate =12L/h

Graph 3: 10 cm clinoptilolite at flow rate of 12L/h measured by ammonium analyzer Applikon Colorimeter The Graph 3 shows that at the beginning, the ammonium concentration of effluent had exceeded breakthrough point (0.03 mg/L) and started at 0.06 mg/L, this is due to some not exchanged feed water exited in the pipe. And the ammonium analyzer Applikon Colorimeter directly tested it at first. Besides of this element, the experiment 4 still can reach at breakthrough start point quickly, the zeolite might be consumed very soon and the roughness of zeolite will influence the ion exchange efficiency.

0

0,01

0,02

0,03

0,04

0,05

0,06

0,07

0,08

0,09

0,1

0 200 400 600 800 1000

NH

4

Co

nce

ntr

atio

n (

mg/

L)

Effluent volume (L)

Breakthrough curve of 10 cm clinoptilolite with 12L/h permeate water

NH4

breakthrough

Permeate

Page 53: Jiali Wang + Kenchouw Wu March 2015 - Oasen

45

20 cm Clinoptilolite (1.0-2.5 mm) Condition: Feed water = RO permeate with probably 0.1 mg/L ammonium concentration Temperature of feed water= 12 0C Flow rate =12L/h

Graph 4: (20 cm bed height zeolite clinoptilolite with flow rate of 12L/h measured by Spectrophotometer Hach-Lang DR 2800)

The samples were checked every 1 hour for the first two hours and then the columns left running overnight. The ammonium concentration was very low at the beginning and started to increase slowly to the breakthrough point. The breakthrough is when the effluent volume is between 150L and 200L. After this, the concentration was increasing faster than before and tending to reach the ammonium concentration of influent. From the tendency, it’s been estimated the concentration of 0.1 mg/L will be reached at effluent volume of 400 L. Remark: At t=0 the measured NH4+ concentration in effluent were very close to that in influent. There might be influent left in the tubes where samples were taken.

0

0,02

0,04

0,06

0,08

0,1

0,12

0 50 100 150 200 250 300 350

NH

4 c

on

cen

trat

ion

(m

g/L)

Effluent volume (L)

Breakthrough curve of 20 cm clinoptilolite with 12L/h permeate water

Column 2 20cm zeolite

Column 3 20cm zeolite

Breakthrough

Permeate

Page 54: Jiali Wang + Kenchouw Wu March 2015 - Oasen

46

1, 10 and 20 cm Clinoptilolite (1.0-2.5 mm) in comparison Condition: Feed water = RO permeate with probably 0.1 mg/L ammonium concentration Temperature of feed water= 11 0C Flow rate =12L/h

Graph 5: 1 cm, 10 cm and 20cm zeolite clinoptilolite with flow rate of 12L/h measured by ammonium analyzer Applikon Colorimeter

Graph 5 shows breakthrough curve of clinoptilolite at three different bed heights, it can be seen that a higher bed height gives a better ion exchange result. Mainly, the ammonium concentration in effluent won’t start at high value that exceeds the breakthrough point. Also, the results provide a good explanation for the assumption that water might leak along with the wall.

0

0,02

0,04

0,06

0,08

0,1

0,12

0 200 400 600 800 1000

Ammonium concentration in effluent (mg/L)

Effluent volume (L)

Breakthrough curve of 1, 10 and 20 cm clinoptilolite with 12L/h permeate water

1 cm zeolite

10 cm zeolite

Column 2 20cm zeolite

Column 3 20cm zeolite

Breakthrough

Permeate

Page 55: Jiali Wang + Kenchouw Wu March 2015 - Oasen

47

10 cm Lewatit S2568H at flow rate of 40L/h Condition: Feed water = RO permeate with average ammonium concentration of 0.136 mg/L

(STD 0.02mg/L) Temperature of feed water= 12.0oC on average Flow rate =40L/h

Graph 6: 10 cm Lewatit S2568H with flow rate of 40L/h measured by ammonium analyzer Applikon Colorimeter

y = 9E-21x6 - 5E-17x5 + 8E-14x4 - 1E-11x3 - 8E-09x2 + 7E-06x + 0,0062

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0,16

0 500 1000 1500 2000 2500 3000

NH

4 c

on

cen

trat

ion

(m

g/L)

Effluent volume (L)

Breakthrough curve of 10cm Lewatit S2568H with 40L/h permeate water

10cm resin 40L/h

Permeate water (average)

Breakthrough

Page 56: Jiali Wang + Kenchouw Wu March 2015 - Oasen

48

10 cm Lewatit S2568H at flow rate of 60L/h Condition: Feed water = RO permeate with average ammonium concentration of 0.129 mg/L

(STD 0.006mg/L) Temperature of feed water= 12.1oC on average

Graph 7: 10 cm Lewatit S2568H with flow rate of 60L/h measured by ammonium analyzer Applikon Colorimeter

y = 2E-18x5 - 2E-14x4 + 7E-11x3 - 8E-08x2 + 4E-05x + 0,0086

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0 500 1000 1500 2000 2500 3000 3500 4000 4500

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 10cm Lewatit S2568H with 60l/h permeate water

10cm resin 60L/h

Breakthrough

Page 57: Jiali Wang + Kenchouw Wu March 2015 - Oasen

49

10 cm Lewatit S2568H at flow rate of 80L/h Condition: Feed water = RO permeate with average ammonium concentration of 0.126 mg/L

(STD 0.006mg/L) Temperature of feed water= 12.0oC on average

Graph 8: 10 cm Lewatit S2568H with flow rate of 80L/h measured by ammonium analyzer Applikon Colorimeter

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0 1000 2000 3000 4000 5000 6000

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 10cm Lewatit S2568H with 80L/h permeate water

10cm resin 80L/h

Breakthrough

Page 58: Jiali Wang + Kenchouw Wu March 2015 - Oasen

50

Breakthrough curve for breakthrough capacity calculation

y = 1E-11x3 + 2E-09x2 + 3E-06x + 0,0152

0

0,005

0,01

0,015

0,02

0,025

0,03

0,035

0,04

0,045

0,05

0 500 1000 1500 2000 2500

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 10cm Lewatit S2568H with 80L/h permeate water

10cm resin 80L/h

Breakthrough

Page 59: Jiali Wang + Kenchouw Wu March 2015 - Oasen

51

10 cm Lewatit S2568H at flow rate of 100L/h Condition: Feed water = RO permeate with ammonium concentration of 0.125 mg/L

(only measured once) Temperature of feed water= 11.9oC

Graph 8: 10 cm Lewatit S2568H with flow rate of 100L/h measured by ammonium analyzer Applikon Colorimeter

y = 3E-08x2 - 1E-05x + 0,0159

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0 500 1000 1500 2000

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 10cm Lewatit S2568H with 100L/h permeate water

10cm resin 100L/h

Permeate water (average)

Page 60: Jiali Wang + Kenchouw Wu March 2015 - Oasen

52

20 cm Lewatit S2568H at flow rate of 40L/h Condition: Feed water = RO permeate with average ammonium concentration of 0.140 mg/L

(STD 0.001mg/L) Temperature of feed water= 11.9oC on average

Graph 9: 20 cm Lewatit S2568H with flow rate of 40L/h measured by ammonium analyzer Applikon Colorimeter

y = 1E-15x4 - 2E-12x3 + 1E-09x2 - 2E-06x + 0,0102

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0,16

0 500 1000 1500 2000 2500 3000

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 20cm Lewatit S2568H with 40L/h permeate water

20cm resin 40L/h

permeate water (average)

Page 61: Jiali Wang + Kenchouw Wu March 2015 - Oasen

53

20 cm Lewatit S2568H at flow rate of 60L/h Condition: Feed water = RO permeate with average ammonium concentration of 0.142 mg/L

(STD 0.02mg/L) Temperature of feed water= 11.8oC on average

Graph 10: 20 cm Lewatit S2568H with flow rate of 60L/h measured by ammonium analyzer Applikon Colorimeter

y = 4E-19x5 - 5E-15x4 + 2E-11x3 - 2E-08x2 + 3E-06x + 0,0132

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0,16

0 1000 2000 3000 4000 5000 6000

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 20cm Lewatit S2568H with 60L/h permeate water

Breakthrough

20cm resin 60L/h

Permeate water(average)

Page 62: Jiali Wang + Kenchouw Wu March 2015 - Oasen

54

20 cm Lewatit S2568H at flow rate of 80L/h Condition: Feed water = RO permeate with average ammonium concentration of 0.136 mg/L

(STD 0.003mg/L) Temperature of feed water= 11.8oC on average

Graph 11: 20 cm Lewatit S2568H with flow rate of 80L/h measured by ammonium analyzer Applikon Colorimeter

y = -2E-18x5 + 1E-14x4 - 3E-11x3 + 2E-08x2 - 4E-06x + 0,0065

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0,16

0 1000 2000 3000 4000

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 20cm Lewatit S2568H with 80L/h permeate water

20cm resin 80L/h

Breakthrough

Permeate water (average)

Page 63: Jiali Wang + Kenchouw Wu March 2015 - Oasen

55

20 cm Lewatit S2568H at flow rate of 100L/h Condition: Feed water = RO permeate with average ammonium concentration of 0.136 mg/L

(STD 0.003mg/L) Temperature of feed water= 12.0oC on average

Graph 12: 20 cm Lewatit S2568H with flow rate of 100L/h measured by ammonium analyzer Applikon Colorimeter

y = 1E-15x4 - 3E-12x3 + 4E-09x2 - 2E-06x + 0,0075

0

0,02

0,04

0,06

0,08

0,1

0,12

0,14

0,16

0 500 1000 1500 2000 2500 3000 3500

NH

4 c

on

cen

trat

ion

(mg/

L)

Effluent volume(L)

Breakthrough curve of 20cm Lewatit S2568H with 100L/h permeate water

20cm resin 100L/h

Permeate water (average)

Breakthrough

Page 64: Jiali Wang + Kenchouw Wu March 2015 - Oasen

56

Appendix F: The design of future treatment plant

Page 65: Jiali Wang + Kenchouw Wu March 2015 - Oasen

57

Appendix H: The pressure drop data of Lewatit S2568H

Page 66: Jiali Wang + Kenchouw Wu March 2015 - Oasen

58