INSTRUMENTS 900 Variable Area... · MAF 900 Series Variable-area Flow-meter With Metallic Measuring Tube is the Variable-area Flow-meter. As the fluid flow upwards in the metal tube,

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INSTRUMENTS 900 Variable Area... · MAF 900 Series Variable-area Flow-meter With Metallic Measuring Tube is the Variable-area Flow-meter. As the fluid flow upwards in the metal tube,
Page 2: INSTRUMENTS 900 Variable Area... · MAF 900 Series Variable-area Flow-meter With Metallic Measuring Tube is the Variable-area Flow-meter. As the fluid flow upwards in the metal tube,
Page 3: INSTRUMENTS 900 Variable Area... · MAF 900 Series Variable-area Flow-meter With Metallic Measuring Tube is the Variable-area Flow-meter. As the fluid flow upwards in the metal tube,

MIAL INSTRUMENTS MAF 900

TECHNICAL PARAMETERS

SPECIFICATION

MAF 900

Page 4: INSTRUMENTS 900 Variable Area... · MAF 900 Series Variable-area Flow-meter With Metallic Measuring Tube is the Variable-area Flow-meter. As the fluid flow upwards in the metal tube,

MIAL INSTRUMENTS MAF 900

MAIN CONSTRUCTIONS AND DIMENSIONS

Every meassuring instrument includes meassuring tube and sensing indicator.

1. Flange2. Tube Body3. Fasten and Enclosed Circle4. Floater stope Shaft5. Orifice hole or Cone tube6. Floater leader Panel7. Floater8. Indicator9. Signal Line connection10. PTFE (Tefelon)

Page 5: INSTRUMENTS 900 Variable Area... · MAF 900 Series Variable-area Flow-meter With Metallic Measuring Tube is the Variable-area Flow-meter. As the fluid flow upwards in the metal tube,

MIAL INSTRUMENTS MAF 900

M10 INDICATOR

ELECTRICITY REMOTE TRANSMIT PERFORMANCE AND WIRING DIAGRAM

DIMENSIONS MAGNETISM FILTER

Page 6: INSTRUMENTS 900 Variable Area... · MAF 900 Series Variable-area Flow-meter With Metallic Measuring Tube is the Variable-area Flow-meter. As the fluid flow upwards in the metal tube,

MIAL INSTRUMENTS MAF 900

KEEP WARM

RESTRICT SWITCH

One or two location limited switch can be installed in the indication, when the flow arrives at the limited value, the alarm switch will send you the alarm value. The flow control figure was set when alarm switch was made. The customer can also open the cover of M10 indicator and set up corresponding position of K1 or K2. SC3.5 limit location switch should use together with the transistor amplifier (WE 77/EX1.2 order alone) in order to fix the explosion proof type. SC 3.5 no limit location switch is common direct type, power supply of 24VDC, three wire direct export about 23.5 V electric signal to the PLC regulating system.

Page 7: INSTRUMENTS 900 Variable Area... · MAF 900 Series Variable-area Flow-meter With Metallic Measuring Tube is the Variable-area Flow-meter. As the fluid flow upwards in the metal tube,