The content of this document has been compiled by perma-tec with mediculous care. Never-the-less, we cannot rule out deviations and reserve the right to make technical changes to the product without any advance notice. We do not assume any judicial responsibility or liability for any damages which may ensue as a result. Necessary modifications will be included in subsequent editions. Compiled and printed: 01/2019

1.

2.

3.

4.

5.

6.

Mounting types

Preparation of lubrication point

Basic Guidelines

Direct mountingRemote mounting with tubeMounting of oil filled units

Pressure testing

Activation und installation

Identification of lubrication system

Pressure test procedure

Page 3: Installation Guide perma FUTURA / perma FUTURA PLUS

© 2019 - perma-tec GmbH & Co. KG | www.perma-tec.com | 3

Schlauchanschlüsse

Art.

No.

Ansc

hlus

stei

le

1 month 3 months 6 months 12 months

This Installation guide provides instructions for the installation of perma FUTURA and helps in preventing basic mounting errors. The guide should be used with the operating instructions.

Drawings are only examples. There are many other possibilities for mounting, depending on local conditions.

Disclaimers of corresponding operating instructions apply.

Installation guides do not affect validation of the operating instructions.

1. Basic Guidelines

• perma FUTURA / perma FUTURA PLUS is a single-point lubrication system. You must use a separate lubrication system for each lubrication point.

• The connection thread of perma FUTURA / perma FUTURA PLUS is BSP R¼ male thread.

• Replace the application‘s grease fitting with a suitable reducer. perma-tec offers a wide assortment of reducers, extensions, tubes, brackets and other accessories. See our product catalogue for the entire overview on perma accessories.

• Ensure that the lube point is prefilled with fresh lubricant before installation. perma offers all of its lubricants in 400 g cartridges for grease guns.

• Select the right lubricant for your application. perma offers a wide variety of standard lubricants for different applications. See our product catalogue for further information.

• All metal to metal connections must be glued together with Loctite® 243™.

• Fill grease lines and accessories with the same lubricant that is contained in the lubrication sys-tem.

• For managing serveral lube points we recommend the use of a lubrication maintenance plan. You can use the free perma MLP software (https://mlp.perma-tec.com) for online administration.

• Please check our product catalogue for more information on how to select suitable lubricant and activator screw (perma FUTURA) / activation cap (perma FUTURA PLUS). You may also download our free perma SELECT APP which is a great tool for the selection of the right lubrication system, lubricant and discharge period.

Page 4: Installation Guide perma FUTURA / perma FUTURA PLUS

| 4

2. Mounting types

Installation of perma FUTURA / perma FUTURA PLUS is possible in all directions.

Reducer for thread connection

2.1 Direct mounting

Direct mounting should be preferred for all lubrication points, to protect the lubrication system against high pressure.

Page 5: Installation Guide perma FUTURA / perma FUTURA PLUS

© 2019 - perma-tec GmbH & Co. KG | www.perma-tec.com | 5

2.2 Remote mounting with tube

• Keep connection lines as short as possible and use tubes with an inside diameter of at least 6 mm. Keep in mind that tube length and bore diameter of bearing housings affect pressure and discharge period of the lubrication system.

• For installation of perma FUTURA / perma FUTURA PLUS use Mounting bracket 1-point G1/4 female (109685).

• Secure tubes with suitable fastenings (brackets, cable ties) to protect against damage and tearing.

• Depending on lubricant and ambient temperature, different tube lengths are possible, e. g. perma Multipurpose grease SF01: 1 m (+20 °C) perma Multipurpose oil SO32: 3 m (+20 °C).

Mounting bracket 1-point G1/4 female (109685)

Hose connector G1/4 male for hose iØ 9.5 mm - push-lock (101554)

Heavy Duty hose up to +100 °C oØ 16 mm x iØ 9.5 mm (101555)

Hose connector G1/4 male for hose iØ 9.5 mm - push-lock (101554)

Reducer for thread connection

Remote mounting is recommended if,

• the ambient temperature of the lubrication point is permanently higher than +40 °C

• the lubrication point is exposed to high vibrations

• no direct access to lubrication point is possible due to safety issues (e. g. removal of protective screens, safety walls or cages)

• it is difficult or dangerous to access the lubrication point

• the lubrication system is exposed to mechanical forces (e. g. falling rocks)

All metal to metal connections must be glued together with Loctite® 243™.

Page 6: Installation Guide perma FUTURA / perma FUTURA PLUS

| 6

2.3 Mounting of oil filled units

2.3.2 Remote mounting

Insert for bracket G1/4 male x G1/4 female (104820)

Bracket (104864)

Oil brush Ø20 mm G1/4 female (101396)

Mounting bracket 1-point G1/4 female (109685)

Tube connector G1/4 male for tube oØ 8 mm straight (101496)Tube up to +80 °C oØ 8 mm x iØ 6 mm (101393)

Bracket (104864)

Tube connector G1/4 male for tube oØ 8 mm straight (101496)

Oil retaining valve G1/4 male x G1/4 female up to +60 °C (104862)

Oil brush 40 x 30 mm G1/4 female (101397)

2.3.1 Direct mounting

All oil filled perma FUTURA / perma FUTURA PLUS come with an integrated oil retaining valve. They can be installed directly on a lubrication brush without the need for an additional oil valve.

Remote installations of oil filled perma FUTURA / perma FUTURA PLUS require an oil retaining valve at the lowest point of the application. This will prevent oil leakage from the lubrication system.

All metal to metal connections must be glued together with Loctite® 243™.

All metal to metal connections must be glued together with Loctite® 243™.

Page 7: Installation Guide perma FUTURA / perma FUTURA PLUS

© 2019 - perma-tec GmbH & Co. KG | www.perma-tec.com | 7

3. Preparation of lubrication point

2. Remove grease nipple or plug screw of connecting thread and check thread size.

3. Insert reducer and install tube and necessary accessory parts.

1. Prior to installation, lubrication point must be cleaned to protect against contamination.

Page 8: Installation Guide perma FUTURA / perma FUTURA PLUS

| 8

4. Lubrication point, accessory parts and tubes must be pre-filled with lubricant. This enables the lubricant to immediately reach the lubrication point.

5. Prefill lubrication point and all grease lines for remote installation.

6. Use a tube prefill adapter to prefill lubrication point and grease lines.

Grease gun (101455)

Hose with rotary joint, slide and hydraulic coupling for grease gun (110199)

Tube prefill adapter

Tube prefill adapter for tube oØ 8 mm (101526) Tube prefill adapter for tube oØ 6 mm (101532)

Hose prefill adapter for Heavy Duty hose (107633)

Tube prefill adapter for VA-flex tubes (107634)

Page 9: Installation Guide perma FUTURA / perma FUTURA PLUS

© 2019 - perma-tec GmbH & Co. KG | www.perma-tec.com | 9

4. Pressure testing

For pressure testing please use perma STAR VARIO with Accessory set for pressure test (101480).

Be sure to use the same lubricant for both, prefilling and LC of perma STAR VARIO.

perma STAR VARIO

Gauge

Stop valve

Accessory set for pressure test

Check counter pressure at lubrication point before installing the lubrication system to guarantee correct function.

Most bearings require 0.5 - 2 bar pressure (without extension tubes). perma FUTURA / perma FUTURA PLUS can be used for these lubrication points.

Accessory set for pressure test (101480)

(order lubrication system separately)

Page 10: Installation Guide perma FUTURA / perma FUTURA PLUS

| 10

perma ACADEMY

4.1 Pressure test procedure

1. Remove grease nipple.

2. Screw reducer onto lube point and connect pressure testing set.

3. Connect perma STAR VARIO to the open outlet. 4. Turn machines on to ensure that lube point is in use and measuring of corresponding counter pressure is possible (Caution: Observe accident prevention regulations). 5. Open stop valve.

6. Push SET button on perma STAR VARIO for approx. 10 seconds until PU lights up on display to trigger an additional discharge/purge.

7. Watch the pressure on the gauge during the additional discharge. If pressure exceeds 6 bar the lubricator will shut off automatically.

8. If pressure doesn‘t rise any more during the additional discharge, max injection pressure has been reached. In order to find out the required system pressure you must wait another 5 minutes. The gauge will then show the system pressure 9. If system pressure exceeds 2 bar you need to „purge“ the lube point by using a mechanical grease gun. Proceed with steps 6 and 7. 10. If counter pressure doesn‘t decrease you need to either select a different lubricant or a different lubricator. Please ask perma-tec to assist you in this matter

Page 11: Installation Guide perma FUTURA / perma FUTURA PLUS

© 2019 - perma-tec GmbH & Co. KG | www.perma-tec.com | 11

FUTURA manufactured by: perma-tec GmbH & Co. KGHammelburger Str. 21 | 97717 EUERDORFwww.perma-tec.com | Tel.: +49 9704 609-0Made in Germany 120 cm³ / 4.06 fl .oz. (US)

FUTURA120

Lubrication System

I M2 c XII 2G c IIC T6 XII 2D c T80°C X0°C < Ta < 40°C

1/1

3/4

1/2

1/1

3/4

1/2 Art. No. 106997 | FU-1709-37337 perma Multipurpose grease SF01

04/17 | 10/17

5. Activation und installation

6. Identification of lubrication system

Installation date and exchange date (to be added by operator)

Art. No. | Serial number (Product designation –year/week of manufacture– internal no.)

Lubricant designation

Start up as following (also refer to operating instructions):

1. Check activator screw to ensure that it contains the gas generating pellet

2. Screw activator screw into the lubrication system

3. Screw activator screw until screw-ring breaks off

4. Shake lubrication system and listen to ensure that the pellet has fallen into the bladder

5. Remove plug and screw lubricator into lube point

The label of the lubrication system shows product-code, manufacturing date, traceability number, lubricant code and part number.

perma FUTURA PLUS:

1. Rotate activation cap 2 – 3 turns (clockwise)

2. Shake lubrication system and listen. Rattling noise indicates that the activation element was

released and has fallen into the electrolyte liquid

3. Remove plug and screw lubrication system into the prepared lubrication point