16
10/31/2008 1 KANALIZACIJA PODELA : 1. GRADSKA KANALIZACIJA 2. KUĆNA KANALIZACIJA 1.GRADSKA KANALIZACIJA GRADSKU MREŽU SAČINJAVAJU RAZVODI KERAMIČKIH CEVI PROFILA Ø150-400 mm I KOLEKTORI KOLEKTORI FEKALIJE ODVODE DO MESTA PREČĆAVANJA ILI DO VODOTOKOVA. KOLEKTORI SE RADE OD BETONA, A NJIHOVO DNO SE OBLAŽE KERAM.PLOČICAMA ILI KLINKER OPEKOM KAO ZAŠTITA BETONA OD KANALSKOG SADRŽAJA POSTAVLJAJU SE NA DUBINI OD 1,0 -2,4 m U NIVOU ULICE POSTAVLJU SE ŠAHTOVI_OKNA RADI KONTORLE I ČĆENJA NA SVAKIH 50-100m ZA SLIVANJE ATMOSFERSKIH VODA POSTAVLJAJU SE SLIVNICI NA RASTOJANJU OD 30-50m

Insalacije u Zgradama-KANALIZACIJA

Embed Size (px)

Citation preview

Page 1: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

1

KANALIZACIJA

• PODELA :1. GRADSKA KANALIZACIJA2. KUĆNA KANALIZACIJA

1.GRADSKA KANALIZACIJA

• GRADSKU MREŽU SAČINJAVAJU RAZVODI KERAMIČKIH CEVI PROFILA Ø150-400 mm I KOLEKTORI

• KOLEKTORI FEKALIJE ODVODE DO MESTA PREČIŠĆAVANJA ILI DO VODOTOKOVA.

• KOLEKTORI SE RADE OD BETONA, A NJIHOVO DNO SE OBLAŽE KERAM.PLOČICAMA ILI KLINKER OPEKOM KAO ZAŠTITA BETONA OD KANALSKOG SADRŽAJA

• POSTAVLJAJU SE NA DUBINI OD 1,0 -2,4 m

• U NIVOU ULICE POSTAVLJU SE ŠAHTOVI_OKNA RADI KONTORLE I ČIŠĆENJA NA SVAKIH 50-100m

• ZA SLIVANJE ATMOSFERSKIH VODA POSTAVLJAJU SE SLIVNICI NA RASTOJANJU OD 30-50m

Page 2: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

2

PODELA GRADSKE KANALIZACIJE

• PREMA NAČINU PRIKUPLJANJA I VR. OTPADNIH VODA:

1. OPŠTI -SKUPNI SISTEM,SVA OTPADNA VODA IDE U ISTU MREŽU

2. SEPARACIONI SISTEMODVAJA SE MREŽA ZAOTPADNU, OD MREŽE ZA ATMOSFERSKU VODU

• PO NAČINU ODVOĐENJA VODE

1.GRAVITACIONA KANALIZACIJA

2.PUMPNA KANALIZACIJA- koristi sisteme pumpi za podizanje vode

- koristi se u ravničarskim ili u brdovitim terenima

TEHNIČKI PROPISI /NEKI OD NJIH/

NE POSTOJE JEDINSTVENI TEHNIČKI PROPISI ZA KANALIZACIJU NA TERITORIJI SRBIJE, VEĆ SVAKI GRAD PROPISUJE NAČIN IZVOĐENJA I KORIŠĆENJA KANALIZACIONIH UREĐAJA

• PREMA NAŠIM PROPISIMA U KOLEKTOR SE MOGU ISPUSTITI SAMOOTPADNE VODE IZ KUPATILA, KUHINJE, SVA METEORSKA VODA,ZANATSKA I INDUSTRIJSKA PREČIŠĆENA VODA OD HEMIJSKIH IMEHANIČKIN SASTOJAKA I PODZEMNA VODA UZ SPECIJALNAODOBRENJA

• NE SME SE U KANALIZACIJU UBACIVATI PEPEO, KISELINE, ALKALIJE ISOLI, KOSTI, KRPE, KUĆNO ĐUBRE, PESAK, TVRDI PREDMETI, VRELAVODA, EKSPLOZIVNE I ZAPALJIVI MATERIJALI

• DOMAĆINSTAVA KOJA NISU SPOJENA NA GRADSKI VODOVOD

NE SMEJU BITI PRIKLJUČENA NI NA GRADSKU KANALIZACIJU

• REZERVOARI ZA LED, RIBNJACI I TOME SL. NE SMEJU SE DIREKTNOVEZATI ZA KANALIZACIJU

• NE DOZVOLJAVA SE UKOPAVANJE HORIZNTALNIH KANALIZACIONIHODVODONIKA IZNAD VODOVODNIH CEVI

• KANALIZ.CEVI IZVAN ZGRADE MORAJU BITI UKOPANE NA MIN.1m ISPODTERENA

Page 3: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

3

KUĆNA KANALIZACIJA

SANITARNA – FEKALNA KIŠNA KANALIZACIJA

KUĆNA KANALIZACIJAsastoji se iz:

� KUĆNE MREŽE� DVORIŠNE MREŽE� PRIKLJUČKA NA

GRADSKU KANALIZACIJU

� ULIČNOG KANALA -ODVODNIKA

Page 4: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

4

TEHNIČKI USLOVI ZA KUĆNU KANALIZACIJU

• UPOTREBLJENI MATERIJAL TREBA DA JE KVALITETAN I DATRAJE KOLIKO I SAM OBJEKAT

• KANALIZACIJA MORA BITI IZVEDENA PO VAŽEĆIM PROPISIMA• SPOJEVI MORAJU BITI BESPREKORNO IZVEDENI• MORA SE OBEZBEDITI DOVOLJNA I STALNA KOLIČINA VODE

ZA ISPIRANJE• SISTEM MORA BITI ZAŠTIĆEN OD MRAZA I NAGLIH

TEMPERATURNIH PROMENA• CEVI NE SMEJU BITI POD UTICAJEM SLEGANJA ZGRADE I

DRUGIH POTRESA• STALNA KONTROLA I ODRŽAVANJE SISTEMA U ISPRAVNOM

STANJU

...ŠTA SE RADI U NASELJIMA ILI POJEDINAČNIM OBJEKTIMA GDE NEMA SISTEMA GRADSKE KANALIZACIJE ?...

KUĆNIM KANALOM SE OTPADNE VODE SPROVODE DO UREĐAJA ZA PREČIŠČAVANJE I TO:

� MALI OBJEKTI U NEPROPUSNE SEPTIČKE JAME

� SANITARNO I TEHNIČKI JE ISPRAVNO SPROVOĐENJE OTPADNIH VODA U SEPTIČKE JAME GDE SE PREČIŠĆAVANJE VRŠI TALOŽEJEM

Page 5: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

5

SASTAVNI DELOVI KANALIZACIJE-KANALIZACIONE CEVI-

izrađuju se :� KERAMIKA� LIVENO GVOŽĐE� AZBEST-CEMENTA� METAL� POLIVINIL-PVC� BETON� STAKLO

PRIMENA FAZONSKIH KOMADA

� PRAVA CEV -za horizontalni razvod mreže� LUKOVI -za promene pravca kanala 45°ili 90°� RAČVE- za ukrštanje i spajanje kanala, razlikujemo

jednostruke i dvostruke, mogu biti prave,kose ili lučne� REDUKCIJE za povećanje profila cevi- redukcioni luk od 90°se postavlja kada vertikala skreće

u horizontalni razvod- redukcioni luk od 45°se radi kada skretanje i

povećavanje cevi radi ulaska u širi kanal� REVIZIONE RAČVE I LUKOVI za kontrolu i čišćenje

mreže u slučaju da se cevi zapuše, pa zbog toga imaju poklopac

Page 6: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

6

• od LIVENOG GVOŽĐA / po Jus-u/ koriste se samo u gornjemrazvodu; izrada u svim oblicima i dužinama – fazonski elementi

• od AZBEST-CEMENTA - cevi SALONIT, prednosti su: lakoća,neporoznost, otpornost na vlagu i temperaturne promene i hemijskeuticaje, laka montaža; izrada u svim oblicima i dužinama – fazonskielementi

• KERAMIČKE cevi /po Jus-u/ koriste se u donjem razvodu, kada suu pitanju otpadne vode sa kiselinama koje nagrizaju matal npr.laboratorije; izrada u svim oblicima i dužinama – fazonski elementi

• METALNE CEVI rade se od olova, mesinga, hromirane iliponiklovane; dolaze u obzir samo kod nameštanja pribora isanitarnih uređaja. Veličina im je colovima, ne postoje fazonskielemeti /sem kod mesinganih/

• PVC CEVI-JUVIDUR CEVI, proizvode se po Jus-u, najvećuprednost od gore navedenih im daje glatkoća unutrašnjosti ispoljašnosti cevi, dužine cevi do 4m (6,8,10,12m); izrada u svimoblicima i dužinama – fazonski elementi, najviše se upotrebljavaju ukućnim, kišnim i industrijskim kanalizacionim razvodima

• BETONSKE CEVI / po Jus-u/, kružnog i jajastog profila,služe zaodvod atmosferskih voda u uličnoj i dvorišnoj mreži; neotporne su nakoroziju,agresivno zemljište i podzemne vode

• STAKLENE CEVI, potpuno providne, imaju najbolja svojstava,pogodne za industriju ili laboratorije

POSTAVLJANJE KANALIZACIONIH CEVIu zemlji:

� ODVODNA CEV SE POLAŽE U ISKOPAN ROV MIN. ŠIRINE 80 cm

� DUBINA ROVA min. 1m� cevi se POLAŽU u sloju

PESKA (sigurno i meko ležište, lakše se izvodi određeni nagib, drenaža terena i ravnomerno prenošenje pritiska ostalih naležućih slojeva na cevi) ili ZDRAVICE(moraju se produbiti ležišta za naglavke)

� ZATRPAVANJE, preko PESKA ide SLOJ SITNE ZDRAVE ZEMLJE oko 50 cm i oprezno se nabija ručnim nabijačima + 20 cm sloja ravne zemlje koja se opet nabija

Page 7: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

7

SPAJANJE CEVI/KERAMIČKE CEVI/

� SPOJNA SREDSTVA SU:KANTRANISANO UŽE-KUČINA I DVOKOMPONENTNI KIT-ASFALT

� MOŽE I POMOĆU GUMENOG UMETKA

� AKO CEV PROLAZI PORED DRVETA NA MESTU NAGLAVKA MORA SE NAPRAVITI PRSTEN OD BETONA U DEBLJINI OD 5 cm

� SPOJEVI MORAJU BITI VODOOTPORNI, NEPROPUSNI ZA GASOVE I ELASTIČNI

SPAJANJE GVOZEDNIH LIVENIH CEVI

• KUČINA + RASTOPLJENO OLOVO

• MOGU SE SPOJITI I POMOĆU GUMENOG UMETKA

Page 8: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

8

SPAJANJE PLASTIČNIH PVC CEVI

• SPAJAJU SE POMOĆU GUMENOG PRSTENA ILI LEPLJENJEM CEVI

• RADI SE PREMA UPUTSTVU PROIZVOĐAČA

DOZVOLJENI NAGIBI-PADOVI

• DOZVOLJEN NAGIB JE U RASPONU OD min. 1.33% (1:75) do max. 6,66% (1:15)

• OPTIMALNI NAGIB JE 3% ZA KRAĆE MREŽE

• KOD PRIMENE MINIMALNOG NAGIBA TREBA OBEZBEDITI KANAL ZA DODATNO ISPIRANJE UVOĐENJEM VEĆEG BROJA KIŠNIH VERTIKALA I REVIZIONIH OTVORA

• NAGIB SE ODREĐUJE POMOĆU INSTRUMENATA ILI POMOĆU RAVNJAČE I LIBELE

Page 9: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

9

VOĐENJE CEVI KROZ OBJEKAT TREBA VODITI RAČUNA O POSTAVLJANJU CEVI PORED ILI

KROZ ZIDOVE, TAVANICE I TEMELJE

• PORED ZIDOVA na 1m od zida sa unutrašnje strane, na 1,5m sa spoljne strane zida, zbog postavljanja zaštite zida i hidroizolacije

• KROZ ZIDOVE , otvor pod uglom od 90°, 5 cm veći od prečnika cevi, cev se na mestu otvora zaštićuje izolacionom trakom

• VETIKALE se moraju kačiti i poduhvatati za zid obujmicama ili kukama na rastojanju od 2m

VOĐENJE HORIZONTALNOG RAZVODA KROZ TAVANICE - MK:

1. U DEBLJINI SAMOG PODA (u sloju cementne košuljice)

2. U SASTAVU MK vešanjem za uzengije ili u prostoru između dva rebra

3. ISPOD MK-horizontalni razvod potpuno vidan

Page 10: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

10

VOĐENJE CEVI U ODNOSU NA TEMELJE

• CEV SE MOŽE VODITI ISPOD TRAKASTOG TEMLJA • CEV SE NE SME VODITI ISPOD TEMELJA SAMCA

KANALIZACIONE VERTIKALE

• FEKALNE VERTIKALE TREBA STAVLJATI PORED KLOZETA

• POSTAVLJAJU SE NA UNUTRAŠNJE ZIDOVE U VIDNE ILI NE VIDLJIVE ŽLJEBOVE ILI U INSTALACIONE BLOKOVE

• KOD GRUPNIH KLOZETA NA JEDNU VERTIKALU SE MOGU PRIKLJUČITI ČETIRI KLOZETA I TO DVA SA JEDNE I DVA SA DRUGE STRANE, AKO IH IMA VIŠE OD ČETIRI UVODI SE JOŠ JEDNA VERTIKALA

Page 11: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

11

...GDE NE SME DA PROĐE FEKALNAVERTIKALA!?...

• NA SPOLJNOM ZIDU ( U SPES.SLUČAJU MORA SE TERMIČKI IZOLOVATI)

• KROZ SKLONIŠTE• KROZ STAMBENE I ADMINISTRATIVNE PROSTORE

( U SPECI.SLUČAJEVIMA MORA SE IZOLAVITI ZVUČNO, POSTAVITI U ŽLJEBOVE, NE SME SE POSTAVLJATI REVIZIJA U TOM DELU PROSTORA)

• KROZ PROSTORIJE ZA ČUVANJE I PRIPREMU HRANE

• KROZ PROSTOR TRAFOSTANICA, TELEFONSKIH CENTRALA I DR. SPEC.ELEKTOINSTALACIJA

PROVETRAVANJE KANALIZACIONE MREŽE• FUNKCIJA SPREČAVANJE POJAVE GASOVA I NEPRIJATNOG MIRISA• SVAKA VERTIKLA IZNAD ZADNJEG IZLIVNOG MESTA MORA IMATI

VENTILACIONI KANAL, A ZAVRŠAVA SE SA VENTILACIONOM GLAVOM KOJA IMA VENTILACIONU KAPU SA OTVORIMA

• NJEN PREČNIK JE UVEĆAN ZA 50mm U ODNOSU NA VERTIKALU• SIFON- SPREČAVA PRODOR NEPRIJATNOG MIRISA I GASOVA U

PROSTORIJE PREKO SANITARNIH UREĐAJA; MESTO MU JE IZMEĐU ODVODNE CEVI I SANITARNOG PRIBORA;RADI SE OD LIVENOG GVOŽĐA ILI PONIKLOVANOG MESINGA, MOŽE SE UGRADITI NAKNADNO ILI JE VEČ U SASTAVU SAMOG UREĐAJA, ON FUNKCIONIŠE AUTOMATSKI TAKO STO SE PRI KORIŠĆENJU PRIBORA VODA IZ SIFONA PRAZNI I PUNI SE SVEŽOM VODOM

Page 12: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

12

PODNA REŠETKA• TO SU SLIVNICI KOJI SE POSTAVLJAJU U PODU

KUPATILA,KLOZETA,PERIONICA• HORIZONTALNA I VERTIKALNA PODNA REŠTKA• IZRADA OD LIVENOG GVOŽĐA, PLASTIKE ILI ČELIKA (preko nje

poklopac okruglog ili kvadratnog oblika od hroma)• CEV KOJA ODVODI VODU IZ PODNE REŠETKE JE Ø70 mm

DELOVI DVORIŠNE MREŽEOLUČNJACI

• DEO SU DVORIŠNE KANALIZACIONE MREŽE• POSTAVLJAJU SE NA DELU TROTOARA• PRIHVATAJU ATMOSFERSKU VODU IZ OLUKA I

TROTOARA• NEMAJU SIFON (AKO SE NALAZE NA TERASAMA

MORAJU IMATI SIFON)

Page 13: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

13

GAJGER SLIVNIK

• IZRAĐUJE SE OD BETONA I LIVENOG GVOŽĐA• DEO DVORIŠNE KANALIZACIONE MREŽE• SLUŽI ZA ODVOD KIŠNICE, SNEGA,...• SA GORNJE STRANE POKLOPAC

Ø150,300,400mm, A DONJI DEO IMA SIFON

REVIZIONA OKNA1.OD OPEKE 2.OD BETONA

� OD OPEKE POSTAVLJAJU SE U ZDRAVOM ZEMLJIŠTU, GDE NEMA KOLSKOG PRILAZA, U PODRUMIMA I U DVORIŠTIMA

� OD BETONA POSTAVLJAJU SE U NASUTOM , SLABOM ZEMLJIŠTU, ILI NA VEĆIM DVORIŠNIM POVRŠINAMA PREKO KOJIH IDE KOLSKI SAOBRAĆAJ

� POSTAVLJAJU SE NA MESTU: 1.UKRŠTANJA DVA ILI VIŠE REVIZIONA KANALA2.KADA JE GLAVNI KANAL DUŽI OD 24 m3.KOD SKRETANJA KANALA POD UGLOM OD 90°� U NJEGA SE SMEŠTAJU REVIZIONE CEVI,LUKOVI I

RAČVE

Page 14: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

14

REVIZIONO OKNO1.OPEKA 2.BETONcev leži na pesku dno silaza je od betona

i u njega su ugrađene poluobličaste cevi kinete

GLAVNA REVIZIONA KASKADNA OKNA1.OPEKA 2.BETON

Page 15: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

15

• VEZA ULIČNOG KANALA OD BETONA I GL.KUĆNOG KANALA

• VEZA ULIČNOG KANALA OD KERAMIKE SA GL.KUĆNIM KANALOM

ISPITIVANJE ISPRAVNOSTI KUĆNE KANALIZACIONE MREŽE

• ISPITIVANJE HORIZONTALNE MREŽEkontrolišu se nagibi, ispravnost i spojevi cevi, mreža se puni vodom ili vodom obojenom krečnim mlekom

• ISPITIVANJE VERTIKALNE MREŽEmreža se puni vodom ili vazduhom pod pritiskom 3,00 bara u vremenu od 15 min, ako su spojevi dobri nivo vode ne sme da pokazuje manju vrednost

• ISPITIVANJE PO POSTAVLJANJU SANITARNIH UREĐAJAvrši se dimom ili mirisom u trajanju od 15 min, sifoni se napune vodom, a onda se spec. aparatom dim ubacuje u donji deo mreže, kada se dim pojavi otvori se zatvore i pristupa se pregledu instalacija, ako svi sifoni drže vodu instalacija je ispravna

Page 16: Insalacije u Zgradama-KANALIZACIJA

10/31/2008

16

PRIJEM, KORIŠĆENJE I ODRŽAVANJE INSTALACIJE KANALIZACIJE

ZA PRIJEM GOTOVE INSTALACIJEPOTREBNO JE IMATI:• ATEST• PISMENU POTVRDU O ISPRAVNOSTI U TOKU I

ZAVRŠETKU RADOVA , KAO I O PRIMENI VAŽEĆIH PROPISA PRILIKOM NJENOG IZVOĐENJA