33
IBM System x3850 X6 基本使用介绍 This presentation is intended for the education of IBM and Business Partner sales personnel. It should not be distributed to customers. IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation Neil Tian

IBM System x3850 X6 基本使用介绍img.zhilankeji.com/ibm/x3850x6_public.pdf · 2014. 11. 7. · x3850 X6 Storage Book >Four 2.5” SAS HDD Bays Std Supports 12Gb Optional Drive

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

  • IBM System x3850 X6基本使用介绍

    © 2006 IBM Corporation

    This presentation is intended for the education of IBM and Business Partner sales personnel. It should not be distributed to customers.

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    Neil Tian

  • x3850 X6 Overview>Up to four Intel Xeon E7-4800v2 Processors

    Socket R1

    Up to 3.4GHz

    6, 8, 10, 12, or 15 Cores

    Up to 37.5MB L3 cache

    >Up to 96 DIMM slots

    Up to 6TB memory *

    4GB/8GB/16GB 1.35v RDIMM

    32GB/64GB 1.35v LRDIMM

    >Up to eight 2.5” SAS/SATA/ HDDs or SSDs

    >Up to sixteen 1.8” SSDs / eXFlash

    >Up to 32 eXFlash DIMMs

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    2

    >Up to 32 eXFlash DIMMs

    >Two USB 3.0 Ports

    >Six USB 2.0 Ports

    Five external

    One internal (Hypervisor)

    >One 1GbE Management Port

    >One Dedicated ML2 Slot for Mezz LOM

    >Two Dedicated PCIe slots for Storage Adapters

    >Up to nine PCIe slots

    >Up to four 1400W/900W AC, 750W DC Power Supplies

    >Ability to scale from 4-way to 8-way cable-free

  • x3850 X6 Front View

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    3

  • x3850 X6 Front View - Book Modules

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    4

  • x3850 X6 Front View - Compute Book Removal

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    5

  • x3850 X6 Rear View

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    6

  • x3850 X6 Rear View - Modules

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    7

  • x3850 X6 Shuttle Removal

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    8

  • x3850 X6 Chassis Mid-Plane

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    9

  • x3850 X6 Storage Book

    >Four 2.5” SAS HDD Bays Std

    Supports 12Gb

    Optional Drive Backplanes

    - Four 2.5” HDD / SDD

    - Eight 1.8” SSD eXflash

    >PCIe Gen 3 Low Profile Adapter Slots

    Dedicated for Storage Adapters

    Slot 12 - x16 Mech / x8 Elect (Primary)

    - Hosts ServeRAID M5210 *

    RAID 0/1/10

    - PCIe Pathing to CPU 0

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    10

    - PCIe Pathing to CPU 0

    Slot 11 - x16 Mech / x8 Elect (Secondary)

    - PCIe Pathing to CPU 1

    >Front Panel I/O

    Two USB 3.0 ports

    One USB 2.0 ports

    VGA port

    >LCD Operator Information Panel

    >Power Switch / Status LEDs

    * Except 3837-A4x

  • x3850 X6 Storage Book - Front View

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    11

  • x3850 X6 Storage Book - LCD Information Panel

    >192x32 pixel LCD Graphical Display

    >Black LCD panel with White Backlighting

    >Supports custom graphic icons

    >Navigation Buttons

    >Displays: MTM and SN System name (from IMM) IMM IP address Code levels (uEFI, IMM, PDSA)

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    12

    Code levels (uEFI, IMM, PDSA) Error logs/Error codes with word descriptions

    (Processor, Memory, PCIe, HDD, PSU, Temp, Fans) BIOS POST Codes If booting from primary or backup uEFI image Checkpoint codes during bootup Remind function Temperature (CPU & ambient) Early LCD Init

  • x3850 X6 Storage Book - Rear View

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    13

  • x3850 X6 Storage Book - Interior View

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    14

  • x3850 X6 Storage Book - ServeRAID M5210

    >LSI SAS3108 12Gbps RAID on Chip (ROC) controller.

    >12, 6, or 3Gbps SAS speeds

    >6 or 3Gbps SATA speeds

    >Two internal x4 HD Mini-SAS connectors (SFF-8643).

    >PCIexpress 3.0 x8 host interface.

    >Support for RAID 0, 1, and 10 standard

    RAID 5, 50, 6, and 60 with optional upgrades.

    >Optional onboard data cache

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    15

    >Optional onboard data cache

    1GB (no battery backup)

    1GB or 2GB with flash backup

    >Optional support for self-encrypting drives (SEDs)

    >Optional support for SSD performance acceleration

  • x3850 X6 DDR3 Compute Book

    >Xeon E7-4800/8800 v2 Series Processor

    Socket R1

    Up to 3.4GHz

    6, 8, 10, 12, or 15 Cores

    Up to 37.5MB L3 Cache

    32 PCIexpress 3.0 Lanes

    4 PCIexpress 2.0 Lanes (DMI)

    3 QPI Links

    - Up to 8GT/s

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    16

    2 Integrated Memory Controllers

    - 2 SMI2 Links per Controller

    >4 Memory Buffers

    Up to 2.67GT/s SMI Link Speed

    Up to 1600MT/s DDR3 Speed

    >24 DIMM slots

    Up to 1.5TB memory

    4GB/8GB/16GB 1.35v RDIMM

    32GB/64GB 1.35v LR-DIMM

  • x3850 X6 DDR3 Compute Book - Front View

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    17

  • x3850 X6 DDR3 Compute Book - Rear View

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    18

  • x3850 X6 DDR3 Compute Book - Interior Left

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    19

  • x3850 X6 DDR3 Compute Book - Interior Right

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    20

  • x3850 X6 DDR3 Compute Book - Processor

    >Die shrink of Sandy Bridge micro architecture

    22nm lithography

    Follow on of Boxboro-EX/Westmere-EX

    >Triples amount of supported memory

    >Supports PCIe 3.0

    >Supports Ivy Bridge Technologies

    Intel® Platform Protection Technology with OS Guard

    Intel® Data Protection Technology with Secure Key

    >

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    21

    >Introduces new technologies

    MCA Recovery Execution Path

    MCA I/O

    Enhanced MCA Gen 1

    PCIe Live Error RecoveryMore information is available on this processor.To view, pause the current presentation and Click Here.

  • x3850 X6 DDR3 Compute Book - Memory

    >Intel Xeon E7-8800v2 / 4800v2 Series processors provide two memory controllers

    Two SMI2 memory channels per controller

    Four memory buffers

    Two operating modes

    - Independent Channel (Performance Mode)

    SMI2 transfer rate up to 2667 MT/s

    DDR3 transfer rate up to 1333 MT/s

    72bits 64 data / 8 parity

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    22

    72bits 64 data / 8 parity

    - Lockstep # (RAS Mode)

    SMI2 transfer rate up to 1600 MT/s

    DDR3 transfer rate up to 1600 MT/s

    144bits 128 data / 16 parity

    >Two DDR3 channels per buffer

    Three DIMMS per DDR3 channel

    24 DIMMS total

    RDIMM and LR-DIMM Supported *

    Up to 1.5TB **# Lockstep not supported if system employs IBM eXFlash memory-channel storage* LR-DIMM not supported if system employs IBM eXFlash memory-channel storage

    8 Rank per channel limit when using RDIMMS** With LR-DIMM options available at announce

  • x3850 X6 DDR3 Compute Book - Memory

    > RAS Features

    Memory Mirroring

    Memory Sparing

    Rank Sparing

    ECC

    Chip Kill

    - Single Device Data Correction (SDDC+1)

    Double Chip Kill

    - Double Device Data Correction (DDDC+1)

    Memory Address Parity Protection

    Memory Demand Scrubbing

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    23

    Memory Demand Scrubbing

    Memory Patrol Scrubbing

    Memory Thermal Throttling

    Failed DIMM Identification

    SMI Clock Failover

    SMI Lane Failover

    SMI Packet Retry

    More information is available on RAS. To view pause the current presentation and Click Here.

  • x3850 X6 DDR3 Compute Book -IBM eXFlash memory-channel storage

    >SSD in a DIMM Slot

    >DDR3 Protocol

    >Configurable As Block Device

    >200GB / 400GB Offerings

    >70K Write IOPS / Device

    >

    IBM eXFlash memory-channel storage

    Storage Subsystem

    MCS Chipset

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    24

    >10 Drive Writes Per Day

    >Scalable

    More information is available on IBM eXFlash memory-channel storage.To view pause the current presentation and Click Here.

    Flash Controller

    Flash Controller

    NAND Flash

    NAND Flash

    System ECC / Error

    Handling

    Protocol Translation

    Data Mapping

    BufferingAddress Mapping

    Timing and

    Control

    Power System: Detection / Protection

  • x3850 X6 DDR3 Compute BookIBM eXFlash DIMM Options

    Option PN Description

    00D8425 IBM eXFlash 200GB DDR3 Storage DIMM

    00D8426 IBM eXFlash 400GB DDR3 Storage DIMM

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    25

  • x3850 X6 Standard I/O Book - Rear

    >Hosts PCH and IMMv2

    PCH DMI2 is muxed CPU0 / CPU1

    >PCIe 3.0 Slots

    CPU1

    - Slot 7 x16 FH/HL

    - Slot 8 x16 Mech / x8 Elect FH/HL

    CPU0

    - Slot 9 x16 FH/HL

    - Slot 10 x8 ML2 / Mezz LOM

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    26

    >USB 2.0

    4 rear / 1 internal (Hypervisor)

    >Video

    >Comm

    >Management Ethernet 1Gb

  • x3850 X6 Standard I/O Book - Interior

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    27

  • x3850 X6 Standard I/O Book - Mezz LOM Options

    Option PN Description

    00D1994 Intel X540 ML2 Dual Port 10GbaseT Adapter for IBM System x

    00D1996 Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter for IBM System x

    00D2026 Broadcom NetXtreme II ML2 Dual Port 10GbaseT for IBM System x

    00D2028 Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ for IBM System x

    00D1998 Intel I350-T4 ML2 Quad PortGbE Adapter for IBM System x

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    28

    00D1998 Intel I350-T4 ML2 Quad PortGbE Adapter for IBM System x

  • x3850 X6 Half Length I/O Book

    >3 Half Length PCIe Slots

    PCIe pathing to CPU 2 or 3 dependant upon bay installed

    Slot 1 / 4

    - x16 PCIe Gen 3

    - 75W

    Slot 2 / 5

    - x8 PCIe Gen 3

    - 75W

    Slot 3 / 6 *

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    29

    Slot 3 / 6 *

    - x16 PCIe Gen 3

    - 75W

    >Hot Swappable

  • x3850 X6 Full Length I/O Book

    >3 Full Length PCIe Slots

    PCIe pathing to CPU2 or CPU3 dependant upon bay installed

    Slot 1 / 4

    - x16 PCIe Gen 3

    - 75W

    - supports double width adapter

    Slot 2 / 5

    - x8 Mechanical / x4 Electrical

    - PCIe Gen 2

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    30

    - PCIe Gen 2

    - Utilizes CPU DMI bus

    Slot 3 / 6 *

    - x16 PCIe Gen 3

    - 75W

    >Auxiliary Power Connectors

    1 - (2 x 3) 75W *

    1 - (2 x 4) 150W

    Supports Adapters up to 300W

    >Hot Swappable* Slot 3 / 6 is unavailable if 2 x 3 Aux Power is utilized

  • x3850 X6 Power and Cooling

    > Up to four HS power supplies Two 900W std most models * N + N Redundancy Options available

    - 900W 100 - 240 VAC- 1400W 100 - 240 VAC **- 750W 40 - 75 VDC

    > Up to ten 60mm system fans 2 motors counter rotating Up to 8 front in CPU Books

    - Fans 1 - 8

    2 rear in std I/O Book- Fans 9 - 10

    > Up to four 60mm power supply fans

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    31

    > Up to four 60mm power supply fans> 6 Cooling Zones

    Zone 1 - HDDs- Fans 9 and 10

    Zone 2 - CPU0, CPU0 DIMMS, ML2, PCIe slot 9- Fans 1 and 2

    Zone 3 - CPU1, CPU1 DIMMS, PCIe slots 7 and 8- Fans 3 and 4

    Zone 4 - CPU2, CPU2 DIMMS, PCIe slots 4, 5, and 6- Fans 5 and 6

    Zone 5 - CPU3, CPU3 DIMMS, PCIe slots 1, 2, and 3- Fans 7 and 8

    Zone 6 - Power Supply Fans

    * Except A4x = one 900W; H1x, A7x, A8x, A9x = four 1400W** 1400W Supplies operated w/ 120VAC Mains = 900W

  • x3850 X6 Supported Operating Systems

    >Microsoft Windows Server 2012 R2>SUSE LINUX Enterprise Server 11 for AMD64/EM64T>Red Hat Enterprise Linux 6 Server x64 Edition>VMware vSphere 5.5 (ESXi)

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    32

  • The End

    THANK YOU

    IBM Systems & Technology Group Education & Sales Enablement © 2014 IBM Corporation

    33