Upload
phamnguyet
View
238
Download
0
Embed Size (px)
Citation preview
LED Surgical LightsHy Series
LED 9
P/N:ENG-HyLED 9 Series-210285-20130201
LED Surgical LightsHyLED 9 Series
Mindray Building, Keji 12th Road South, High-tech Industrial Park,Nanshan, Shenzhen 518057, P.R. China
Tel: +86 755 8188 8998 Fax: +86 755 26582680E-mail: [email protected] Website: www.mindray.com
Mindray is listed on the NYSE under the symbol”MR”
2012 Shenzhen Mindray Bio-medical Electronics Co., LTD. All rights reserved.
is a trademark owned by Shenzhen Mindray Bio-medical Electronics Co., LTD. Specifications subject to changes without prior notice.
The materials and information provided via this brochure are distributed internationally, but not all the products or services found on this brochure are necessarily available in your country or area. Please contact local office or agents to make sure of the availability of the relevant products or services.
Miami
Novosibirsk
Branch OfficeR&D Center
Mindray Medical Netherlands B.V. Drs.W.van Royenstraat 8, 3871 AN Hoevelaken, The NetherlandsVoice: (31-33) 254-4911Fax: (31-33) 253-4280
Mindray Medical Italy S.r.l.Via Girardo Patecchio, 4 20141 Milano, ItalyVoice: (39-02) 5737-401Fax: (39-02) 5523-2018
Mindray Medical España S.L.Avenida Manoteras 38, Edificio B, Bajo B008. 28050-Madrid SpainVoice: (34-91) 392-3754 Fax: (34-91) 392-3756
Mindray Medical Germany GmbHZwischen den Bächen 4, 64625 Bensheim, GermanyVoice: (49) 6251-17524-0Fax: (49) 6251-17524-20
Mindray (UK) Limited3 Percy Road, St Johns Park, Huntingdon, Cambs, PE29 6SZ United KingdomVoice: (44) 1480-416-840Fax: (44) 1480-436-588
Mindray Medical France SARLEuroparc Creteil 1 allée des cerisiers 94000 CRETEIL, FranceVoice: (33-1) 4513-9150Fax: (33-1) 4513-9151
Mindray Medical Sweden ABRissneleden 136, 174 57 Sundbyberg, SwedenVoice: (46) 8 555 54 121Fax: (46) 8 555 54 101
Mindray Medical Rus Co.Ltd2 Zvenigorodskaya Street, 13, bld 41, 123022 Moscow, RussiaVoice: (7-499) 553-6036Fax: (7-499) 553-6039
Mindray Medical Colombia S.A.SRoom No.702, Torre UNIKA,Carrera 9 No.77-67, Bogota, ColombiaVoice: (57-1) 3130892 / 3210916
Mindray do Brasil – Comércio e Distribuição de Equipamentos Médicos Ltda.Rua Tavares Bastos, 329, Perdizes, São Paulo - SP, CEP 05012-020Voice: (55-11) 3124-8026Fax: (55-11) 3078-8035
Mindray Medical Mexico S. de R.L. de C.V. Félix Parra # 175 Colonia. San José Insurgentes Sur Delegación Benito Juárez 03900 México, D. F.Voice: (52-55) 5661-9450 / (52-55) 5662-6620Fax: (52-55) 5662-6597
PT.Mindray Medical IndonesiaThe East 11th Floor, Unit 08 Jl. Dr. Ide Anak Agung Gde Agung Kav. E 3.2 No.1 Jakarta 12950Voice: (6221) 2902-7280Fax: (6221) 2902-7283
Mindray Medical EgyptGround Floor -11 El Imam Metwally El Sharawi Street, Sheraton Heliopolis - El Nozha, Cairo, Egypt Voice: (2) 02 22691047Fax: (2) 02 22691046
Mindray Medical India Pvt. Ltd. (Delhi Office)Unit No. 401/402 & G-31, NDM-1, Netaji Subhash Place, Wazirpur District Center, New Delhi - 110 034.Voice: (91-11) 4923-0000Fax: (91-11) 4923-0030
Mindray Medical India Pvt. Ltd. (Mumbai office)B-404, City Point, Andheri Kurla Road, Andheri East, Mumbai, 400 059, IndiaVoice: (91-22) 4020-0000Fax: (91-22) 4020-0011
Mindray Medikal Teknoloji İstanbul Ltd. Şti. (Customer Service Address)Turan Güneş Bulvarı Aleksander Dupçek Caddesi NO:18/A Yıldız Çankaya, ANKARA Zip: 06550 istanbul, TurkeyVoice: (90-312) 441 96 92Fax: (90-312) 441 96 93
Mindray Medikal Teknoloji İstanbul Ltd. Şti. (Ankara office)Turan Güneş Bulvarı Aleksander Dupçek Caddesi NO:18/A Yıldız Çankaya, ANKARA Zip: 06550Voice: (90-312) 441 96 92Fax: (90-312) 441 96 93
Mindray Medical Vietnam Co.,Ltd.Unit 2, 4th Floor, "B" Building, Broadway Office Park, 102 Nguyen Luong Bang Blvd., Tan Phu Ward, Dist. 7, HCMC, VietnamVoice: (84) 8 5413-6970 Fax: (84) 8 5413-6971
Mindray Medical Thailand Limited1768 Thai summit Tower Room 407, 4th floor, New petchaburee Road, Kwaeng Bangkapi, Khet Huai Khwang, Bangkok 10320, Thailand Voice: (66) 2652-788Fax: (66) 26527-266
As a pioneer of the operating theatre solution supplier, Mindray has merged the latest technology into the HyLED 9 Series surgical lights to provide the best illumination to the surgery.The surgeon can focus his attention only on the operation since it is not necessary to worry about the performance or readjustment. Since the medical team has to stand below the surgical light, some parts of the LEDs will be inevitably obstructed. But with the intelligent AICS, the loss of such illumination will be compensated. The obstructed parts of the LEDs will not turn off while other parts of bulbs will be brighter to maintain the center illumination.
AICS (Automatic Illumination Control System )
AICSAutomatic Illumination Control System
Key FeaturesVerified Certificate Din-1946 Part 4Incredibly long service time up to 40, 000 hoursExcellent luminous efficiencyLow power consumptionHeat-free light sourceA maximum of central illumination 160, 000 luxMaximum depth of illuminance up to 1, 200mmFreely adjustable field diameter from 180mm to 330mmStandard color temperature at 4,350K, or with various options (3,800K-5,000K)330 rotatable integrated HD camera°
LED Surgical LightsHyLED 9 Series
330 mm 180 mm
This "Cross" shape of light head can be put in a proper position, which makes doctors' heads in the four corners. And it can also provide a homogeneous light beam & light patch, as what the right picture shows. Light field diameter is adjustable from 180 to 330 mm for various of size operating fields. Up to 330mm of the maximum diameter, together with a perfect match of double light head , HyLED 9 Series is the ideal light source for the surgery, which has a big wound filed to be illuminated, such as cardiovascular or orthopedic operation.
Light Field Diameter
LED Surgical LightsHyLED 9 Series
Depending on different surgical situations, the surgeon can choose daylight-quality light, at the standard of 4,350 K, or give operation at a higher or lower color temperature . This function will be helpful to distinguish the difference between various tissue types and the perception of true tissue colors. Additionally, each surgeon has individual sensitivity towards color, which also requires various options.
Selectable Color Temperature ( Optional )Better Function for Cardiac Surgery
There are Three Commercial Methods of Color Temperature Regulation:
Primary color mixedThe three primary colors (red, green and blue) are blended. The drawback is that surgeons standing under the light will obstruct the light sources for certain colors when a color temperature is configured, because light color derives from blending light sources from different directions. As color temperature changes with the movement of surgeons
Choose color temperature by powerEnergy output is tuned to change the color temperature of light source. The drawback is that LED luminous efficacy will attenuate as temperature of the internal circuit board rises. Therefore, color temperature rise will cause energy output to increase, which affects heat dissipation from the surgical light. Dynamic unbalance in heat dissipation in turn causes temperature rises, light source instability and service life instability.
Flu
x
Time
LED Flux
LED Temperature
RGB
Without red Without green Without blue
Color temperature pre-mixed Mindray uses a special light source system with a uniform mixed light of cool white light and warm white light; the light colors within the surgical area will not change even when surgeons block some of the light source during surgery. Therefore, the optimal color temperature adjustment mode is only recommended in the extreme conditions such as cardiac surgery. In addition, this adjustment mode is only available in HyLED9700/9500 series.
High Performance
Sensitive sensor
Each LED bulb with individual circuit can be replaced one by one, which will lower down the maintenance cost.
Long service time with a minimum lifetime of 40,000 hours, each latest generation LED illuminates far longer than traditional light sources or other brands LEDs.
Several functions can be adjusted electronically:
Switch on/offIllumination intensity (15-100%, 20 steps)Light filed diameter Color temperature(3800-5000K, 5 steps)Ambient mode for endoscopy Camera control
4,350K
3,300K
5,000K
3,800K
Color display with different color temperature
MIN
DR
AY
HyL
ED
STA
ND
ARD
LE
D
GA
SD
ISC
HA
RGE
TEC
HN
OLO
GY
HA
LOG
EN
BULB
TE
CH
NO
LOG
Y
1000hrs
,40,0
00hrs
20,000hrs
5,0
00hrs
Closest Partner of Surgeon
Picture Elements
Optical Zoom
Digital Zoom
S/N Ratio
Electric shutter
Video Output
Carrier Arm Camera/Integrated Camera
Two Mega Pixels HD Camera
10 X ( f=5.1-50.1mm, F=1.8-2.1 )
12 X ( 120X with optical zoom )
>50dB
1/2-1/10,000s
Component
Two Mega Pixels HD Camera
Unique electrical control patternEvery single LED in a light head generates a homogeneous light field, together providing a light with uniform illumination across the entire surgical light field. HyLED 9 Series use the unique electrical control pattern towards adjustable light filed diameter: increase or decrease the quantity of the lighted bulbs. Compared with mechanical pattern, such adjustment will be much smoother without any rapid illumination change, which can protect surgeon 's eyes.
Say “no” to refocusOnce positioned, HyLED 9 Series will work as the closest partner of the surgeon. Stable spring arm from Ondal, intelligent AICS function together with excellent performance, there will be no any other concern about the refocus.
Perfectly integrated into laminar flowThanks to the "cross" shape light head design, smooth finish and small air flow contact surfaces, HyLED 9 Series surgical lights generate minimized turbulence in the laminar flow.
Illumination in depth Because of the excellent photology design in the light head , the maximum depth of the beam is approximately 1,200 mm which is very important in case of the small and deep wound field.
Optional configuration for Correlated Color Temperature
Integrated HD camera with 330 rotation and reserved function, only available for HyLED9700
。
330°
How to Select the Right Surgical Light ?
2,044mm
477mm-1,554mm
2,400mm
False Ceiling
Flange tube L=225mm
Floor
2,044mm1,110mm-2,230mm
2,400mm
False Ceiling
Flange tube L=225mm
Floor
2,231mm 814mm-1,871mm
2,700mm
False CeilingFlange tube L=225mm
Floor
2,700mm 2,231mm
False CeilingFlange tube L=225mm
Floor
1,413mm-2,533mm
2,118mm
678mm
-1,868mm
2,700mm
False CeilingFlange tube L=225mm
Floor
2,700mm 1,299mm-2,419mm
False Ceiling
Flange tube L=225mm
Floor
2,118mm
Wrong Correct
Wrong Correct
Wrong Correct
LED Surgical LightsHyLED 9 Series
Technical Specifications
HyLED 9700
Light field diameter(at 1m distance)*
Central illuminance (at 1m distance)
Depth of illumination (L1+L2)
Color Temperature **
Color rendering index
160,000 lux
1,200mm
95
120 000 lux,
1,200mm
95
HyLED 9500
Shadow dilution with tube
Shadow dilution with one mask
Shadow dilution with tube and one mask
Shadow dilution with two masks
Shadow dilution with tube and two masks
Radiant energy
Ambient illumination
Temperature rise area around surgeon's head-
Temperature rise operative field-
Service life of bulb
Max. power consumption of all light sources
Power supply
Automatic illumination control system
≤1℃
≥ ,40 000h
118w
100VAC~240VAC 50/60Hz,
≤ ℃1
Optional
≤ ℃1
≥40 000h,
90w
100VAC~240VAC 50/60Hz,
≤ ℃1
No
100%100%
75%85% (AICS function, Optional)
65%
60%
80%90% (AICS function, Optional)
60%70% (AICS function, Optional) 55%
55%65% (AICS function, Optional) 50%
23.6 mW/m *lux 23.6 mW/m *lux
12,800 lux 9,800 lux
Number of LED Bulbs
Dimming Range
Light Head Dimension
Integrated Camera Optional
60
No
88
8~100% 8~100%
740mm 620mm
180-330mm 180-330mm
Standard: 4,350KVariable CCT: 3,800~5,000K** Variable CCT: 3,800~5,000K**
Standard: 4,350K
: : Five ranks for variable color temperature: 3,800/4,100/4,350/4 ,700/5,000K.: The technical specifications above will be available from March, 2013.
Optional configuration for Color Temperature is variable (3,800-5,000K), available from March, 2013.
******
All the advanced and reliable facilities from Mindray technology, are perfectly matched to give you total support !Mindray OR Total Solution
Welcome to Mindray Showroom