7
LED Surgical Lights Hy Series LED 9 P/N:ENG-HyLED 9 Series-210285-20130201 LED Surgical Lights HyLED 9 Series Mindray Building, Keji 12th Road South, High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China Tel: +86 755 8188 8998 Fax: +86 755 26582680 E-mail: [email protected] Website: www.mindray.com Mindray is listed on the NYSE under the symbol”MR” 2012 Shenzhen Mindray Bio-medical Electronics Co., LTD. All rights reserved. is a trademark owned by Shenzhen Mindray Bio-medical Electronics Co., LTD. Specifications subject to changes without prior notice. The materials and information provided via this brochure are distributed internationally, but not all the products or services found on this brochure are necessarily available in your country or area. Please contact local office or agents to make sure of the availability of the relevant products or services. Miami Novosibirsk Branch Office R&D Center Mindray Medical Netherlands B.V. Drs.W.van Royenstraat 8, 3871 AN Hoevelaken, The Netherlands Voice: (31-33) 254-4911 Fax: (31-33) 253-4280 Mindray Medical Italy S.r.l. Via Girardo Patecchio, 4 20141 Milano, Italy Voice: (39-02) 5737-401 Fax: (39-02) 5523-2018 Mindray Medical España S.L. Avenida Manoteras 38, Edificio B, Bajo B008. 28050-Madrid Spain Voice: (34-91) 392-3754 Fax: (34-91) 392-3756 Mindray Medical Germany GmbH Zwischen den Bächen 4, 64625 Bensheim, Germany Voice: (49) 6251-17524-0 Fax: (49) 6251-17524-20 Mindray (UK) Limited 3 Percy Road, St Johns Park, Huntingdon, Cambs, PE29 6SZ United Kingdom Voice: (44) 1480-416-840 Fax: (44) 1480-436-588 Mindray Medical France SARL Europarc Creteil 1 allée des cerisiers 94000 CRETEIL, France Voice: (33-1) 4513-9150 Fax: (33-1) 4513-9151 Mindray Medical Sweden AB Rissneleden 136, 174 57 Sundbyberg, Sweden Voice: (46) 8 555 54 121 Fax: (46) 8 555 54 101 Mindray Medical Rus Co.Ltd 2 Zvenigorodskaya Street, 13, bld 41, 123022 Moscow, Russia Voice: (7-499) 553-6036 Fax: (7-499) 553-6039 Mindray Medical Colombia S.A.S Room No.702, Torre UNIKA,Carrera 9 No.77-67, Bogota, Colombia Voice: (57-1) 3130892 / 3210916 Mindray do Brasil – Comércio e Distribuição de Equipamentos Médicos Ltda. Rua Tavares Bastos, 329, Perdizes, São Paulo - SP, CEP 05012-020 Voice: (55-11) 3124-8026 Fax: (55-11) 3078-8035 Mindray Medical Mexico S. de R.L. de C.V. Félix Parra # 175 Colonia. San José Insurgentes Sur Delegación Benito Juárez 03900 México, D. F. Voice: (52-55) 5661-9450 / (52-55) 5662-6620 Fax: (52-55) 5662-6597 PT.Mindray Medical Indonesia The East 11th Floor, Unit 08 Jl. Dr. Ide Anak Agung Gde Agung Kav. E 3.2 No.1 Jakarta 12950 Voice: (6221) 2902-7280 Fax: (6221) 2902-7283 Mindray Medical Egypt Ground Floor -11 El Imam Metwally El Sharawi Street, Sheraton Heliopolis - El Nozha, Cairo, Egypt Voice: (2) 02 22691047 Fax: (2) 02 22691046 Mindray Medical India Pvt. Ltd. (Delhi Office) Unit No. 401/402 & G-31, NDM-1, Netaji Subhash Place, Wazirpur District Center, New Delhi - 110 034. Voice: (91-11) 4923-0000 Fax: (91-11) 4923-0030 Mindray Medical India Pvt. Ltd. (Mumbai office) B-404, City Point, Andheri Kurla Road, Andheri East, Mumbai, 400 059, India Voice: (91-22) 4020-0000 Fax: (91-22) 4020-0011 Mindray Medikal Teknoloji İstanbul Ltd. Şti. (Customer Service Address) Turan Güneş Bulvarı Aleksander Dupçek Caddesi NO:18/A Yıldız Çankaya, ANKARA Zip: 06550 istanbul, Turkey Voice: (90-312) 441 96 92 Fax: (90-312) 441 96 93 Mindray Medikal Teknoloji İstanbul Ltd. Şti. (Ankara office) Turan Güneş Bulvarı Aleksander Dupçek Caddesi NO:18/A Yıldız Çankaya, ANKARA Zip: 06550 Voice: (90-312) 441 96 92 Fax: (90-312) 441 96 93 Mindray Medical Vietnam Co.,Ltd. Unit 2, 4th Floor, "B" Building, Broadway Office Park, 102 Nguyen Luong Bang Blvd., Tan Phu Ward, Dist. 7, HCMC, Vietnam Voice: (84) 8 5413-6970 Fax: (84) 8 5413-6971 Mindray Medical Thailand Limited 1768 Thai summit Tower Room 407, 4th floor, New petchaburee Road, Kwaeng Bangkapi, Khet Huai Khwang, Bangkok 10320, Thailand Voice: (66) 2652-788 Fax: (66) 26527-266

HyLED 9 Series - 3.imimg.com3.imimg.com/data3/GR/XX/MY-6040946/led-surgical-light.pdf · maximum diameter, together with a perfect match of double light head , HyLED 9 Series is the

Embed Size (px)

Citation preview

LED Surgical LightsHy Series

LED 9

P/N:ENG-HyLED 9 Series-210285-20130201

LED Surgical LightsHyLED 9 Series

Mindray Building, Keji 12th Road South, High-tech Industrial Park,Nanshan, Shenzhen 518057, P.R. China

Tel: +86 755 8188 8998 Fax: +86 755 26582680E-mail: [email protected] Website: www.mindray.com

Mindray is listed on the NYSE under the symbol”MR”

2012 Shenzhen Mindray Bio-medical Electronics Co., LTD. All rights reserved.

is a trademark owned by Shenzhen Mindray Bio-medical Electronics Co., LTD. Specifications subject to changes without prior notice.

The materials and information provided via this brochure are distributed internationally, but not all the products or services found on this brochure are necessarily available in your country or area. Please contact local office or agents to make sure of the availability of the relevant products or services.

Miami

Novosibirsk

Branch OfficeR&D Center

Mindray Medical Netherlands B.V. Drs.W.van Royenstraat 8, 3871 AN Hoevelaken, The NetherlandsVoice: (31-33) 254-4911Fax: (31-33) 253-4280

Mindray Medical Italy S.r.l.Via Girardo Patecchio, 4 20141 Milano, ItalyVoice: (39-02) 5737-401Fax: (39-02) 5523-2018

Mindray Medical España S.L.Avenida Manoteras 38, Edificio B, Bajo B008. 28050-Madrid SpainVoice: (34-91) 392-3754 Fax: (34-91) 392-3756

Mindray Medical Germany GmbHZwischen den Bächen 4, 64625 Bensheim, GermanyVoice: (49) 6251-17524-0Fax: (49) 6251-17524-20

Mindray (UK) Limited3 Percy Road, St Johns Park, Huntingdon, Cambs, PE29 6SZ United KingdomVoice: (44) 1480-416-840Fax: (44) 1480-436-588

Mindray Medical France SARLEuroparc Creteil 1 allée des cerisiers 94000 CRETEIL, FranceVoice: (33-1) 4513-9150Fax: (33-1) 4513-9151

Mindray Medical Sweden ABRissneleden 136, 174 57 Sundbyberg, SwedenVoice: (46) 8 555 54 121Fax: (46) 8 555 54 101

Mindray Medical Rus Co.Ltd2 Zvenigorodskaya Street, 13, bld 41, 123022 Moscow, RussiaVoice: (7-499) 553-6036Fax: (7-499) 553-6039

Mindray Medical Colombia S.A.SRoom No.702, Torre UNIKA,Carrera 9 No.77-67, Bogota, ColombiaVoice: (57-1) 3130892 / 3210916

Mindray do Brasil – Comércio e Distribuição de Equipamentos Médicos Ltda.Rua Tavares Bastos, 329, Perdizes, São Paulo - SP, CEP 05012-020Voice: (55-11) 3124-8026Fax: (55-11) 3078-8035

Mindray Medical Mexico S. de R.L. de C.V. Félix Parra # 175 Colonia. San José Insurgentes Sur Delegación Benito Juárez 03900 México, D. F.Voice: (52-55) 5661-9450 / (52-55) 5662-6620Fax: (52-55) 5662-6597

PT.Mindray Medical IndonesiaThe East 11th Floor, Unit 08 Jl. Dr. Ide Anak Agung Gde Agung Kav. E 3.2 No.1 Jakarta 12950Voice: (6221) 2902-7280Fax: (6221) 2902-7283

Mindray Medical EgyptGround Floor -11 El Imam Metwally El Sharawi Street, Sheraton Heliopolis - El Nozha, Cairo, Egypt Voice: (2) 02 22691047Fax: (2) 02 22691046

Mindray Medical India Pvt. Ltd. (Delhi Office)Unit No. 401/402 & G-31, NDM-1, Netaji Subhash Place, Wazirpur District Center, New Delhi - 110 034.Voice: (91-11) 4923-0000Fax: (91-11) 4923-0030

Mindray Medical India Pvt. Ltd. (Mumbai office)B-404, City Point, Andheri Kurla Road, Andheri East, Mumbai, 400 059, IndiaVoice: (91-22) 4020-0000Fax: (91-22) 4020-0011

Mindray Medikal Teknoloji İstanbul Ltd. Şti. (Customer Service Address)Turan Güneş Bulvarı Aleksander Dupçek Caddesi NO:18/A Yıldız Çankaya, ANKARA Zip: 06550 istanbul, TurkeyVoice: (90-312) 441 96 92Fax: (90-312) 441 96 93

Mindray Medikal Teknoloji İstanbul Ltd. Şti. (Ankara office)Turan Güneş Bulvarı Aleksander Dupçek Caddesi NO:18/A Yıldız Çankaya, ANKARA Zip: 06550Voice: (90-312) 441 96 92Fax: (90-312) 441 96 93

Mindray Medical Vietnam Co.,Ltd.Unit 2, 4th Floor, "B" Building, Broadway Office Park, 102 Nguyen Luong Bang Blvd., Tan Phu Ward, Dist. 7, HCMC, VietnamVoice: (84) 8 5413-6970 Fax: (84) 8 5413-6971

Mindray Medical Thailand Limited1768 Thai summit Tower Room 407, 4th floor, New petchaburee Road, Kwaeng Bangkapi, Khet Huai Khwang, Bangkok 10320, Thailand Voice: (66) 2652-788Fax: (66) 26527-266

As a pioneer of the operating theatre solution supplier, Mindray has merged the latest technology into the HyLED 9 Series surgical lights to provide the best illumination to the surgery.The surgeon can focus his attention only on the operation since it is not necessary to worry about the performance or readjustment. Since the medical team has to stand below the surgical light, some parts of the LEDs will be inevitably obstructed. But with the intelligent AICS, the loss of such illumination will be compensated. The obstructed parts of the LEDs will not turn off while other parts of bulbs will be brighter to maintain the center illumination.

AICS (Automatic Illumination Control System )

AICSAutomatic Illumination Control System

Key FeaturesVerified Certificate Din-1946 Part 4Incredibly long service time up to 40, 000 hoursExcellent luminous efficiencyLow power consumptionHeat-free light sourceA maximum of central illumination 160, 000 luxMaximum depth of illuminance up to 1, 200mmFreely adjustable field diameter from 180mm to 330mmStandard color temperature at 4,350K, or with various options (3,800K-5,000K)330 rotatable integrated HD camera°

LED Surgical LightsHyLED 9 Series

330 mm 180 mm

This "Cross" shape of light head can be put in a proper position, which makes doctors' heads in the four corners. And it can also provide a homogeneous light beam & light patch, as what the right picture shows. Light field diameter is adjustable from 180 to 330 mm for various of size operating fields. Up to 330mm of the maximum diameter, together with a perfect match of double light head , HyLED 9 Series is the ideal light source for the surgery, which has a big wound filed to be illuminated, such as cardiovascular or orthopedic operation.

Light Field Diameter

LED Surgical LightsHyLED 9 Series

Depending on different surgical situations, the surgeon can choose daylight-quality light, at the standard of 4,350 K, or give operation at a higher or lower color temperature . This function will be helpful to distinguish the difference between various tissue types and the perception of true tissue colors. Additionally, each surgeon has individual sensitivity towards color, which also requires various options.

Selectable Color Temperature ( Optional )Better Function for Cardiac Surgery

There are Three Commercial Methods of Color Temperature Regulation:

Primary color mixedThe three primary colors (red, green and blue) are blended. The drawback is that surgeons standing under the light will obstruct the light sources for certain colors when a color temperature is configured, because light color derives from blending light sources from different directions. As color temperature changes with the movement of surgeons

Choose color temperature by powerEnergy output is tuned to change the color temperature of light source. The drawback is that LED luminous efficacy will attenuate as temperature of the internal circuit board rises. Therefore, color temperature rise will cause energy output to increase, which affects heat dissipation from the surgical light. Dynamic unbalance in heat dissipation in turn causes temperature rises, light source instability and service life instability.

Flu

x

Time

LED Flux

LED Temperature

RGB

Without red Without green Without blue

Color temperature pre-mixed Mindray uses a special light source system with a uniform mixed light of cool white light and warm white light; the light colors within the surgical area will not change even when surgeons block some of the light source during surgery. Therefore, the optimal color temperature adjustment mode is only recommended in the extreme conditions such as cardiac surgery. In addition, this adjustment mode is only available in HyLED9700/9500 series.

High Performance

Sensitive sensor

Each LED bulb with individual circuit can be replaced one by one, which will lower down the maintenance cost.

Long service time with a minimum lifetime of 40,000 hours, each latest generation LED illuminates far longer than traditional light sources or other brands LEDs.

Several functions can be adjusted electronically:

Switch on/offIllumination intensity (15-100%, 20 steps)Light filed diameter Color temperature(3800-5000K, 5 steps)Ambient mode for endoscopy Camera control

4,350K

3,300K

5,000K

3,800K

Color display with different color temperature

MIN

DR

AY

HyL

ED

STA

ND

ARD

LE

D

GA

SD

ISC

HA

RGE

TEC

HN

OLO

GY

HA

LOG

EN

BULB

TE

CH

NO

LOG

Y

1000hrs

,40,0

00hrs

20,000hrs

5,0

00hrs

Closest Partner of Surgeon

Picture Elements

Optical Zoom

Digital Zoom

S/N Ratio

Electric shutter

Video Output

Carrier Arm Camera/Integrated Camera

Two Mega Pixels HD Camera

10 X ( f=5.1-50.1mm, F=1.8-2.1 )

12 X ( 120X with optical zoom )

>50dB

1/2-1/10,000s

Component

Two Mega Pixels HD Camera

Unique electrical control patternEvery single LED in a light head generates a homogeneous light field, together providing a light with uniform illumination across the entire surgical light field. HyLED 9 Series use the unique electrical control pattern towards adjustable light filed diameter: increase or decrease the quantity of the lighted bulbs. Compared with mechanical pattern, such adjustment will be much smoother without any rapid illumination change, which can protect surgeon 's eyes.

Say “no” to refocusOnce positioned, HyLED 9 Series will work as the closest partner of the surgeon. Stable spring arm from Ondal, intelligent AICS function together with excellent performance, there will be no any other concern about the refocus.

Perfectly integrated into laminar flowThanks to the "cross" shape light head design, smooth finish and small air flow contact surfaces, HyLED 9 Series surgical lights generate minimized turbulence in the laminar flow.

Illumination in depth Because of the excellent photology design in the light head , the maximum depth of the beam is approximately 1,200 mm which is very important in case of the small and deep wound field.

Optional configuration for Correlated Color Temperature

Integrated HD camera with 330 rotation and reserved function, only available for HyLED9700

330°

How to Select the Right Surgical Light ?

2,044mm

477mm-1,554mm

2,400mm

False Ceiling

Flange tube L=225mm

Floor

2,044mm1,110mm-2,230mm

2,400mm

False Ceiling

Flange tube L=225mm

Floor

2,231mm 814mm-1,871mm

2,700mm

False CeilingFlange tube L=225mm

Floor

2,700mm 2,231mm

False CeilingFlange tube L=225mm

Floor

1,413mm-2,533mm

2,118mm

678mm

-1,868mm

2,700mm

False CeilingFlange tube L=225mm

Floor

2,700mm 1,299mm-2,419mm

False Ceiling

Flange tube L=225mm

Floor

2,118mm

Wrong Correct

Wrong Correct

Wrong Correct

LED Surgical LightsHyLED 9 Series

Technical Specifications

HyLED 9700

Light field diameter(at 1m distance)*

Central illuminance (at 1m distance)

Depth of illumination (L1+L2)

Color Temperature **

Color rendering index

160,000 lux

1,200mm

95

120 000 lux,

1,200mm

95

HyLED 9500

Shadow dilution with tube

Shadow dilution with one mask

Shadow dilution with tube and one mask

Shadow dilution with two masks

Shadow dilution with tube and two masks

Radiant energy

Ambient illumination

Temperature rise area around surgeon's head-

Temperature rise operative field-

Service life of bulb

Max. power consumption of all light sources

Power supply

Automatic illumination control system

≤1℃

≥ ,40 000h

118w

100VAC~240VAC 50/60Hz,

≤ ℃1

Optional

≤ ℃1

≥40 000h,

90w

100VAC~240VAC 50/60Hz,

≤ ℃1

No

100%100%

75%85% (AICS function, Optional)

65%

60%

80%90% (AICS function, Optional)

60%70% (AICS function, Optional) 55%

55%65% (AICS function, Optional) 50%

23.6 mW/m *lux 23.6 mW/m *lux

12,800 lux 9,800 lux

Number of LED Bulbs

Dimming Range

Light Head Dimension

Integrated Camera Optional

60

No

88

8~100% 8~100%

740mm 620mm

180-330mm 180-330mm

Standard: 4,350KVariable CCT: 3,800~5,000K** Variable CCT: 3,800~5,000K**

Standard: 4,350K

: : Five ranks for variable color temperature: 3,800/4,100/4,350/4 ,700/5,000K.: The technical specifications above will be available from March, 2013.

Optional configuration for Color Temperature is variable (3,800-5,000K), available from March, 2013.

******

All the advanced and reliable facilities from Mindray technology, are perfectly matched to give you total support !Mindray OR Total Solution

Welcome to Mindray Showroom