Horizontal Multistage Centrifugal Pumps
S M A R T P U M P I N G
Nuton horizontal multistage centrifugal pumps are engineered to perfection with utmost care and stringent quality control at all stages to ensure
a trouble free service.
DESCRIPTION
Nuton horizontal multistage centrifugal pumps are axial suction and vertical radial delivery with threaded ports. The impellers, diffusers and
shaft of these pumps are made of stainless steel and designed to deliver the best possible hydraulic efficiency. This pump is a non-self priming
horizontal centrifugal pump with mechanical shaft seal and sealing is by means of a bellows mechanical seal.
These pumps are powered by at any enclosed fan cooled A.C. induction motor, suitable for continuous duty. Motor stator is made of low watt
loss steel laminations assembled under pressure and rigidly locked in the frame. Dynamically balanced rotor ensures vibration free and noise
free operations. Shaft is made of quality stainless steel. All single-phase pumps are incorporated with thermal over load protector. These
pumps require an adequate starter/motor protector control panel.
Applications
Industrial and domestic water pressure boosting and distribution
Small farms
Pumping of clean liquids in industry
Car washing
Hotels & Multistory Buildings
Salient Features
Fitted with motor protector
SS304 Impellers and stage casings
Designed for wide voltage fluctuations
Aluminum body for better the heat dissipation
Higher working pressure
Sturdy and compact
Pumped Liquids
Thin, clean, non-aggressive and non-explosive liquids without solid particles or fibers
IMPORTANT NOTES
Pump should not be operated dry. Install dry run prevent to protect the pumpset from dry running. Use appropriated size, good quality cable
and starter / protection devices. Use low fiction good quality pipes. The pipe diameters must never be smaller than the pump connections.
Install pump according to our recommended Head range. Reduce number of ends, elbows, T-bends as much as possible in the pipe line. Pump
should be run for few minutes at least once in 2 days to prevent from seizing. Use frictionless quality foot valve for Horizontal Multistage
Centrifugal Pumps. Avoid fatal electrical shock injury by disconnection power before working on or around the pumping system. Only
technically qualified personnel must perform the works complying with local electricity rules and regulations. To reduce the risk of electrical
shock operation, an appropriate earthing is mandatory. The performance data and curves are at rated voltage and only indicative. Pipe sizes
mentioned in inches are nominal pipe sizes and are nearest conversion of mm. All pumps are only suitable for pumping clear, cold, fresh, non-
aggressive, non-explosive water without abrasives, solid particles or fibers.
Horizontal Multistage Centrifugal Pumps NHM
13
Horizontal Multistage Centrifugal Pumps
S M A R T P U M P I N G
Temperature
Permissible amount of sand
Chlorine ion density
Allowable solids
Specific gravity
Hardness (Drinking Water)
Viscosity
Turbidity
pH
45°C (max.)32 8 gm / m (max.)
500 ppm (max.)
3 000 ppm (max.)
1 .004 (max.)
3 00 (max.)6 21 .75 x 10 m / Sec. (max.)
5 0 ppm silica scale (max.)
6 .5 to 8.5
CHARACTERISTICS OF PUMPED LIQUIDS MATERIALS OF CONSTRUCTION
a
b
c
d
e
f
g
h
i
Part Name
Pumps Casing
Pump Bracket
Impeller
Diffuser
Motor Frame
Shaft
Mechanical Seal
Base Plate
Type S
Cast Iron
Cast Iron
SS-304
SS-304
Aluminum
SS-410
Carbon & Ceramic
Mild Steel
The conditions below apply to the curves shown on the following pages.
Ÿ Curve tolerance are according to ISO 9906, Annex-A.
Ÿ The performance are taken at rated voltage & rated frequency.
Ÿ Actual discharge depends on availability of water in Well / Tank, height of water column form the suction pipe end.
Ÿ The measurements were made with airless water at 20°C. When pumping liquids with a higher density than of
water, motor with correspondingly higher outputs must be used.
Ÿ Pipe fiction losses have not been included in the performance curves & performance tables.
Ÿ The pipe connection threads are given as per BSP standard.
Ÿ The given performance are for specific materials of constructions.
3Ÿ The main scales of the Performance curves are meter and m /h which have been given for head and flow
respectively.
PERFORMANCE CURVE CONDITIONS
Horizontal Multistage Centrifugal Pumps NHM
14
Horizontal Multistage Centrifugal Pumps
S M A R T P U M P I N G
0
4
8
12
16
20
24
28
32
36
40
44
48
52
56
60
64
68
72
76
80[m]
3 ST
4 ST
5 ST
6 ST
0
50
100
150
200
250
[ft]
[lpm]0 5 10 15 20 25 30 35 40 450
5
10
15
20
25
30
35
[%]
0 0.5 1 1.5 2 2.5 [m/h]3
NHM 150 hz
ISO 9906 Annexure A
Flow Rate
Eff
.H
ead
NHM-1
M3/H 0 0.4 0.8 1 1.2 1.6 2
LPM 0 7 13 17 20 27 33
NHM-1 0.37 0.5 3 28 27 26 24 23 20 16
NHM-1 0.45 0.6 4 37 36 34 32 30 27 21
NHM-1 0.55 0.75 5 46 45 42 40 37 33 27
NHM-1 0..75 1 6 55 54 50 48 45 39 32
StageH.P.MODEL
Discharge
(HE
AD
(M
ET
ER
S)
K.W.
15
Horizontal Multistage Centrifugal Pumps
S M A R T P U M P I N G
0
3
6
9
12
15
18
21
24
27
30
33
36
39
42
45
48
51
54
57
[m]
2 ST
3 ST
4 ST
5 ST
6 ST
0
20
40
60
80
100
120
140
160
180
[ft]
[lpm]0 10 20 30 40 50 600
5
10
15
20
25
30
35
[%]
0 0.5 1 1.5 2 2.5 3 3.5 4 [m/h]3
NHM 250 hz
Eff
f.H
ead
ISO 9906 Annexure A
Flow Rate
M3/H 0 0.8 1.6 2.5 3 3.5 4
LPM 0 13 27 42 50 58 67
NHM-2 0.37 0.5 2 19 18 16 14 11 9 7
NHM-2 0.45 0.6 3 28 27 24 20 16 14 10
NHM-2 0.55 0.75 4 37 35 31 26 21 18 13
NHM-2 0.75 1 5 46 44 39 33 26 22 16
NHM-2 0.93 1.25 6 55 52 46 39 31 26 19
NHM - 2
MODEL K.W. H.P. Stage
Discharge
(HE
AD
(M
ET
ER
S)
16
Horizontal Multistage Centrifugal Pumps
S M A R T P U M P I N G
0
4
8
12
16
20
24
28
32
36
40
44
48
52
56
60
64
68
72
76
80[m]
3 ST
4 ST
5 ST
6 ST
0
50
100
150
200
250
[ft]
[lpm]0 10 20 30 40 50 60 7005
1015202530354045
[%]
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 [m/h]3
NHM 350 hz
Head
EF
F.
Flow Rate
ISO 9906 Annexure A
NHM-3M
3/H 0 0.8 1.6 2.4 3 3.6 4.2
LPM 0 13 27 40 50 60 70
NHM-3 0.55 0.75 3 29 28 27 25 22 19 15
NHM-3 0.75 1 4 38 37 35 32 30 26 20
NHM-3 0.93 1.25 5 47 46 44 40 37 32 25
NHM-3 1.1 1.5 6 56 55 52 48 44 38 30
MODEL K.W. H.P. Stage
Discharge
(HE
AD
(M
ET
ER
S)
7
Horizontal Multistage Centrifugal Pumps
S M A R T P U M P I N G
0
3
6
9
12
15
18
21
24
27
30
33
36
39
42
45
48
51
54
57
[m]
2 ST
3 ST
4 ST
5 ST
6 ST
0
20
40
60
80
100
120
140
160
180
[ft]
[lpm]0 20 40 60 80 100 120 1400
5
10
15
20
25
30
35
[%]
0 1 2 3 4 5 6 7 8 9 [m/h]3
NHM 550 hz
Head
EF
F.
Flow Rate
ISO 9906 Annexure A
NHM - 5 Discharge
M3/H 0 2 4 6 7 8 9
LPM 0 33 66 100 117 133 150
Discharge
MODEL K.W. H.P. Stage
NHM-5 0.45 0.6 2 19 16 14 12 10 7 5
NHM-5 0.75 1 3 28 24 21 17 14 11 7
NHM-5 0.93 1.25 4 37 32 27 22 19 14 9
NHM-5 1.1 1.5 5 46 40 34 28 23 17 11
NHM-5 1.5 2 6 55 47 41 33 27 20 13
(HE
AD
(M
ET
ER
S)
TOLL FREE: 1800 102 4466
ww
w.y
awed
o.co
m |
02/
14
Version: AC02/02/14
Marketed by: AVENTURA COMPONENTS PRIVATE LIMITED
Corporate Office: A-1/152 Neb Sarai, IGNOU Road, New Delhi-110 068 INDIA T: +91 (11) 4310 0516/522 F: +91 (11) 4310 0599 M: +91 97176 90522E: [email protected] Website: www.aventura.co.in
Present at: • Ahmedabad • Bengaluru • Chennai• Hyderabad • Kolkata • Mumbai • Pune •Jaipur •Lucknow • Nagpur • Coimbatore