64
Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure trans- ducer which allows the customer to select the configuration which best fits the needs of the application. Choose from mul- tiple accuracies, outputs, pressure ports, electrical terminations, and pressure ranges. The FP2000 is available with gage, absolute, barometric, or vacuum reference and, best of all, they delivery in two weeks or less. FEATURES mV/V, 0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, 4 mA to 20 mA Gage, absolute, barometric, vacuum Differential (wet/wet, wet/dry) Intrinsically safe option 5 CE available 6 FP2000 pressure sensors are custom built from stocked compo- nents, and most are shipped in 10 business days or less. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings Approved Approved Approved Intrinsically safe amp Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Embed Size (px)

Citation preview

Page 1: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Configurable Pressure TransducerModel FP2000

DESCRIPTIONThe FP2000 series is a configurable differential pressure trans-

ducer which allows the customer to select the configuration

which best fits the needs of the application. Choose from mul-

tiple accuracies, outputs, pressure ports, electrical terminations,

and pressure ranges.

The FP2000 is available with gage, absolute, barometric, or

vacuum reference and, best of all, they delivery in two weeks or

less.

FEATURES• mV/V,0Vdcto5Vdc,0Vdcto10Vdc,4mAto20mA

• Gage,absolute,barometric,vacuum

• Differential(wet/wet,wet/dry)

• Intrinsicallysafeoption5

• CEavailable6

FP2000 pressure sensors are custom built from stocked compo-

nents,andmostareshippedin10businessdaysorless.Please

seehttp://sensing.honeywell.com/TMsensor-shipforupdated

listings

Approved Approved ApprovedIntrinsically safe amp

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 2: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2Honeywell•SensingandControl

Model FP2000

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Accuracy1 Seeaccuracytable

Output(selectable) mV/V(seeaccuracytable),0Vdcto5Vdc,0Vdcto10Vdc,or4mAto20mA(twowire)

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -40°Cto116°C[-40°Fto240°F]

Temperature, compensated 4°Cto60°C[40°Fto140°F]2

Temperature, error band 2

0.10%accuracy ±0.5%fullscale

0.25%accuracy ±1.0%fullscale

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Excitation(calibration)

Amplified

(4mAto20mA;0Vdcto5Vdc)

9Vdcto28Vdc

Amplified

(0Vdcto10Vdc) 15Vdcto28Vdc

Unamplified(mV/V) 10Vdc

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media3 Gas,liquid

Overload - safe

positive(+)direction 4Xfullscaleor3000psi,whichever is less

negative(-)direction 4Xfullscaleor250psi,whichever is less

Overload - burst

positive(+)direction 3000psi

negative(-)direction 500psi

Pressure port 200%overcapacity

Wetted parts material HaC276&316Lstainlesssteel

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 3: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell•SensingandControl3

Configurable Pressure Transducer

PRESSURE RANGES AND RANGE CODESpsi Range

codetorr Range

codemBar Range

codekPa Range

codeBar Range

codeinHg

Range code

mmHg

Range code

in H2O

Range code

Gage/Absolute

0.5* AN1* AP2* AR2.5* AS5 AT10 AV15 BJ25 BL30 BM50 BN75 BP100 BR150 CJ200 CL250 CN300 CP400 CQ500 CR600 CS750 CT1000 CV1500 DJ2000 DL2500 DM3000 DN5000 DR6000 DS7500 DT10000 DV

15** HA50** HB135** HC250 HD750 HE1500 HF

35** JA70** JB175** JC350 JD700 JE750 JF1000 JG3500 JH7000 JI10000 JK

2** KA7** KB15** KC35 KD70 KE100 KF200 KG300 KH700 KJ1000 KL1500 KM1700 KN2000 KP3000 KQ5000 KR7000 KS10000 KT15000 KU20000 KV35000 KW50000 KY70000 KZ

0.035** MA0.1** MB0.2 MC0.5 MD1 ME2 MF3.5 NA5 MG7 NB10 MH20 MI30 MJ35 NC50 MK70 ND100 ML135 NE350 NG500 MM700 NH

1** UB2** UD5 UF10 UA15 UC20 UE30 UG50 UI60 UK80 UM100 UP200 UH300 UJ500 UL1000 UN0-32 US16-32 UQ26-32 UR

15** VA50** VB135 VC250 VD750 VE1500 VF

5** WB10** WA20** WC30** WE50** WG100 WI120 WK150 WM200 WP300 WR500 WS

Barometric(Order codeFPB)

0-30 UG16-32 UQ26-32 UR

Vacuum(Order codeFPV)

1 AP5 AT10 AV15 BJ

50 HB135 HC250 HD750 HE

35 JA70 JB175 JC350 JD700 JE750 JF1000 JG

7 KB15 KC35 KD100 KF

0.035 MA0.1 MB0.2 MC0.5 MD1 ME

10 UA20 UE30 UG

15 VA50 VB135 VC250 VD750 VE

10 WA20 WC30 WE50 WG100 WI

Differential(Order codesFDD, FDW)

0.5 AN1 AP2 AR2.5 AS5 AT10 AV15 BJ25 BL30 BM50 BN75 BP100 BR150 CJ200 CL250 CN300 CP400 CQ500 CR600 CS750 CT1000 CV

15 HA50 HB135 HC250 HD750 HE1500 HF

35 JA70 JB175 JC350 JD700 JE750 JF1000 JG3500 JH7000 JI10000 JK

2 KA7 KB15 KC35 KD70 KE100 KF200 KG300 KH700 KJ1000 KL1500 KM1700 KN2000 KP3000 KQ5000 KR7000 KS10000 KT15000 KU20000 KV35000 KW50000 KY

0.035 MA0.1 MB0.2 MC0.5 MD1 ME2 MF3.5 NA5 MG7 NB10 MH20 MI30 MJ35 NC50 MK70 ND

1 UB2 UD5 UF10 UA15 UC20 UE30 UG50 UI60 UK80 UM100 UP200 UH300 UJ500 UL1000 UN0-32 US16-32 UQ26-32 UR

15 VA50 VB135 VC250 VD750 VE1500 VF

5 WB10 WA20 WC30 WE50 WG100 WI120 WK150 WM200 WP300 WR500 WS

*0.5psito2.5psirangesarenotavailableforabsolutepressure**Notavailableinabsolute

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 4: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

4Honeywell•SensingandControl

Model FP2000

INTERNAL AMPLIFIERS

Amplifier specifications

Unamplified output: Option 2u

Voltage output: Option 2d

Voltage output: Option 2g

Current two-wire: Option 2p

Output signal Seeaccuracytable 0Vdcto5Vdc 0Vdcto10Vdc 4mAto20mA

Input power (voltage) 10Vdc 9Vdcto28Vdc 15Vdcto28Vdc 9Vdcto32Vdc

Input power (current) 2mA@10Vdc 10mA 15mA 4mAto24mA

Frequency response Naturalfrequency 300Hz 300Hz 300Hz

Power supply rejection N/A 60dB 60dB 60dB

Operating temperature -40°Cto116°C[-40°Fto240°F]

-29°Cto85°C[-20°Fto185°F]

-29°Cto85°C[-20°Fto185°F]

-29°Cto85°C[-20°Fto185°F]

Reverse voltage protection N/A Yes Yes Yes

Short circuit protection N/A Momentary Momentary Yes

Amplifier specifications

Voltage output: Option 2e

Voltage output: Option 2f

Intrinsically safe amp: Option 2n (2N)***

Current two-wire: Option 2y

Output signal 0Vdcto5Vdc 0Vdcto10Vdc 4mAto20mA 4mAto20mA

Input power (voltage) 9Vdcto28Vdc 15Vdcto28Vdc 9Vdcto28Vdc 9Vdcto32Vdc

Input power (current) 10mA 15mA 4mAto24mA 4mAto24mA

Frequency response 2000Hz 2000Hz 2000Hz 2000Hz

Power supply rejection 60dB 60dB 60dB 60dB

Operating temperature -29°Cto85°C[-20°Fto185°F]

-29°Cto85°C[-20°Fto185°F]`

-29°Cto85°C[-20°Fto185°F]

-29°Cto85°C[-20°Fto185°F]

Reverse voltage protection Yes Yes Yes Yes

Short circuit protection Momentary Momentary Yes Yes

ACCURACY

Non-amplifed output @ 10 Vdc excitation

Gage and absolute Vacuum Barometric Differential

0.10%accuracy 50mV4 25mV 40mV 50mV4

0.25%accuracy 100mV 50mV 80mV 100mV

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 5: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell•SensingandControl5

Configurable Pressure Transducer

MOUNTING DIMENSIONS

Code 6a: 6-pin, vented, Bendix style

Code 6m: 4-pin, vented, standard DIN (43650)

Code 6n: 4-pin, vented, mini DIN

Code 6q: 4-conductor, vented, integral cable, 1,52 m [5 ft]

Code 6r: 4-conductor, vented, integral cable, conduit fitting 1,52 m [5 ft]

Code 5a1/4-18 NPT female

Code 5b1/4-18 NPT male

Code 5c7/16-20 UNF female

Code 5d7/16-20 UNF male

Code 5fG 1/4 B female

Code 5gG 1/4 B male

Less than 1000 psi

Greater than 1500 psi

Code 5h1/8-27 NPT female

Code 5i1/8-27 NPT male

Code 5pM12-1.5 male

Code 5qM12-1.5 female

Code 5r9/16-18 SAE male

Code 5s9/16-18 SAE female

Less than 1000 psi

Greater than 1500 psi

FPA, FPG, FPB, FPV

FDW FDD

Pressure ports

Electrical termination

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 6: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

6Honeywell•SensingandControl

Model FP2000

Unamplified output: Option 2u

Voltage output: Option 2d/2e

Voltage output: Option 2g/2f

Current two-wire: Option 2p/2y

Intrinsically safe amp: Option 2n (2N)***

Bendix PTIH-10-6P (Option 6a)Noshuntcal A (+)Excitation

B (+)ExcitationC (-)ExcitationD (-)ExcitationE (-)OutputF (+)Output

A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 5VdcD (+)OutputE NoconnectionF Noconnection

A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 10VdcD (+)OutputVdcE NoconnectionF Noconnection

A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Noconnection

A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE CasegroundF Noconnection

With shunt cal(option3d)

A (+)ExcitationB (-)ExcitationC (+)OutputD (-)OutputE NoconnectionF ShuntCal

A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 5VdcD (+)OutputE NoconnectionF Shuntcal

A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 10VdcD (+)OutputE NoconnectionF Shuntcal

A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Shuntcal

A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Shuntcal

Std. DIN 43650 (Option 6m)Noshuntcal 1 (+)Excitation

2 (+)Output3 (-)Output4 (-)Excitation

1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase

1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase

1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Noconnection

1 (+)Supply2 (+)Output3 CasegroundGND Noconnection

With shunt cal(option3d)

NotApplicable 1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal

1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal

1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Shuntcal

1 (+)Supply2 (+)Output3 CasegroundGND Shuntcal

Mini DIN 40050 (Option 6n)Noshuntcal 1 (+)Excitation

2 (+)Output3 (-)Output4 (-)Excitation

1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase

1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase

1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Noconnectiontocase

1 (+)Supply2 (+)Output3 CasegroundGND Noconnection

With shunt cal(option3d)

NotApplicable 1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal

1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal

1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Shuntcal

1 (+)Supply2 (+)Output3 CasegroundGND Shuntcal

1.83 m [5 ft] integral cable (Option 6q)Noshuntcal R (+)Excitation

Bl (-)ExcitationG (-)OutputW (+)Output

R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 5Vdc

R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 10Vdc

R (+)SupplyBl (+)Output4mAto 20mA

R (+)SupplyBl (+)Output4mAto 20mAW Case ground

With shunt cal(option3d)

NotApplicable R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 5Vdc

R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 10Vdc

R (+)SupplyBl (+)Output4mAto 20mAG Shuntcal

R (+)SupplyBl (+)Output4mAto 20mAW Case groundG Shuntcal

Conduit fitting (Option 6r)Noshuntcal R (+)Excitation

Bl (-)ExcitationG (-)OutputW (+)Output

R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 5Vdc

R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 10Vdc

R (+)SupplyBl (+)Output4mAto 20mA

R (+)SupplyBl (+)Output4mAto 20mAW Case ground

With shunt cal(option3d)

NotApplicable R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 5Vdc

R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 10Vdc

R (+)SupplyBl (+)Output4mAto 20mAG Shuntcal

R (+)SupplyBl (+)Output4mAto 20mAW Case groundG Shuntcal

Note:Forwiringcodes,R=red;Bl=black;W=white;G=green.Colorspecifiescableandletterornumberspecifiesconnection***SeeHoneywell’sWebsiteformostup-to-dateinformationregardingIntrinsicallySafeapprovalsref.#008-0547-00.

WIRING CODES

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 7: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell•SensingandControl7

Configurable Pressure TransducerHow to orderThe FP2000 Order Code isaneasywayforyoutoorderexactlywhatyouwantthefactorytobuild.Simplymakeoneselectionineachofthesixrequiredcategories.Chooseaddersandaccessoriesonlyifyourequirethem.ByvisitingourWebsiteatwww.honeywell.com/sensing you can view complete technical specifications for the FP2000, or click to our on-line shopping site and actually place your order.

Step 1

Transducer type Type Codeo Pressure-gage FPGo Pressure-absolute FPAo Differential-wet/wet FDWo Pressure-barometric FPBo Differential-wet/dry FDDo Pressure-vacuum FPV

Unit typeo psi o baro torr o in Hgo mBar o mm Hgo kPa o in H2O

Step 2

Pressure rangeGage,absolute,anddifferential Range code Range codeo 0.5psi AN o 250psi CNo 1psi AP o 300psi CPo 2psi AR o 400psi CQo 2.5psi AS o 500psi CRo 5psi AT o 600psi CSo 10psi AV o 750psi CTo 15psi BJ o 1000psi CVo 25psi BL o 1500psi DJo 30psi BM o 2000psi DLo 50psi BN o 2500psi DMo 75psi BP o 3000psi DNo 100psi BR o 5000psi DRo 150psi CJ o 6000psi DSo 200psi CL o 7500psi DT o 10000psi DV

Barometric Vacuumo 16-32inHga UQ o 1psi APo 26-32inHga UR o 5psi ATo 0-30inHga UG o 10psi AV o 15psi BJ

Accuracy Accuracycodeo 0.10% 1o 0.25% 2

Step 3

Output Basic Ifadding Ifadding output 9dor9f 1y,3d,9e code (<5000psi) or14co mV/V 2u NA 2uo 5Vdc 2d NA 2eo 10Vdc 2g NA 2fo 4mAto20mA 2p 2n(2N) 2y

NOTE:IfanyADDERSarerequired,theoutputcodemustberevised.Seestep4.

Pressure Port Port codeo 1/4-18NPTfemale 5ao 1/4-18NPTmale 5bo 7/16-20UNFfemale 5co 7/16-20UNFmale 5do G1/4Bfemale 5fo G1/4Bmale 5go 1/8-27NPTfemale 5ho 1/8-27NPTmale 5io M12x1.5male 5po M12x1.5female 5qo 9/16-18UNFSAEmale 5ro 9/16-18UNFSAEfemale 5s

Electrical connector Connector codeo BendixPTIH-10-6P 6ao DIN43650 6mo MiniDIN(40050) 6no Integralpolyurethane5ftcable 6qo 1/2x14NPTconduit5ftcableexit 6r

Step 4

Adders Addercodeo Enhancedthermals 1y Gage:0°Fto180°F Absolute:0°Fto180°F Differential:0°Fto180°F Barometric:30°Fto170°F Vacuum:10°Fto170°Fo Shuntcal 3do ISrating 9do CErating 9eo ISandCErating 9fo Zeroandspanadjustments 14c

o mV/V 2uo 5Vdc 2eo 10Vdc 2fo 4mAto20mA(CEonly) 2yo 4mAto20mA(ISonly 2n(2N)o 4mAto20mA(ISandCE) 2n(2N)

NOTE:Ifyouchooseanyadderoutputfromstep4,youmustrevise your output code selection using this output code chart.ISoutputsavailableonlyonrangesupto5000psi.

AccessoriesMatingconnectorsonly Acc.codeo MiniDIN AA161o Bendix AA111

Matingconn.with15ft.cableforBendixconnector(6A) Without With shunt shunt(3d)o mV/V AA113 AA513o 4mAto20mA AA116 AA516o 0to5/0to10Vdc AA117 AA517

Step 5

Example order code FDW 1 CN 2y 5b 6a 1y AA116

Selection Description CodeTransducertype Differentialwet/wet FDWAccuracy 0.10% 1Pressurerange 250psi CNOutput 4mAto20mA 2yPressureport 1/4-18NPTmale 5bElectricaloutputconnections BendixPTIH-10-6P 6aAdders Enhancedtemperaturerange 1yAccessories Matingconnectorwithcable AA116

Theremustbeacodeineachofthesixbasiccodeboxes.Iftherearenoaddersoraccessorieschosen,leavetheboxesblank.

Description Basic code Adder code (see step 4)

Order codeType Accuracy Range Output Pressure Elect.conn. Extended Shuntcal. IS/CErated Pots

Accessorycode

Zeroandspanadjustmentsarelocatedontheside.Seedrawingfordetails.NozeroandspanadjustmentsareavailableonmV/Voutputoption.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 8: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008835-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model FP2000 Configurable Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.

Failure to comply with these instructions could result in death or serious injury.

NOTES1. Accuraciesstatedareexpectedforbest-fitstraightlineforaller-

rors, including linearity, hysteresis, and non-repeatability through zero.

2. For low pressure ranges, temperature effects may vary.3. Thewet/wetdifferentialpressuretransducerhastwoseparate,

weldedHastelloydiaphragms.Inwet/dryunit,thewetport(highport)hasall-weldedstainlesssteelandHastelloyconstruction.Thedryport(lowport)hasnoisolationdiaphragm.

4. Forlowgageanddifferentialpressurerangesat0.10%accuracy,non-amplifiedoutput@10Vdcexcitation=100mV.

5. Rangeuptoandinclude5000psi.6. Notavailablewith6m.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 9: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Low Range Wet/Wet Differential Pressure Transducer

Model KZ

DESCRIPTIONThe Model KZ offers an all-welded stainless steel assembly that

eliminates internal “O” ring leaks and material compatibility. The

Model KZ line pressure zero shift specification can be reduced

to less than 0.5 % FS/1000 psi by the use of an internal line

pressure sensor and analog correction circuit. Line pressures

are available up to 5000 psig with safe overload of either side

up to the maximum line rating. The natural resonant frequency is

increased with the Model KZ because of a stiffer pressure sens-

ing element and the all-welded assembly.

A variety of options are available with the Model KZ including

choice of pressure adaptors, pressure ports, internal amplifiers,

and electrical terminations.

FEATURES• 0.25%FSaccuracy

• 0.5psidto30psid

• All-weldeddesign

• mV/V(standard),4mAto20mA,0Vdcto5Vdc,or0Vdc

to10Vdcoutput

• CEapproved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 10: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2Honeywell•SensingandControl

Model KZ

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges ±0.5,1,2,5,10,1525,30psid**

Accuracy ±0.25%fullscale

Linearity ±0.15%fullscale(typical)

Hysteresis ±0.10%fullscale(typical)

Non-repeatability ±0.05%fullscale(typical)

Output(standard)0.5psid 1.0mV/V(nominal)

Output(standard)1psidto4psid

1.5mV/V(nominal)

Output(standard)5psidto30psid

2.0mV/V(nominal)

Line pressure 1500 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -1°Cto88°C[30°Fto190°F]

Temperature, compensated -1°Cto54°C[30°Fto130°F]

Temperature, effect, zero ±0.5 % full scale/100 °F

Temperature, effect, span ±0.5 % reading/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation(calibration) 10Vdc

Excitation(acceptable) Upto10Vdcorac

Insulation resistance 5000mOhm@50Vdcmax.

Bridge resistance 350ohm(nominal)

Shunt calibration data Included

Elec.termination(std) BendixPTIH-10-6Porequivalent

Matingconnector(notincl.) BendixPT06A-10-6Sorequiv.(AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Allfluidandgasescompatiblewith316stainless steel

Overload-safe 1500 psi

Pressure port 1/8-27NPTfemale(2)

Dead volume 0.4cu.in

Wetted parts material 316stainlesssteel

Weight 1.9kg[4.2lb]

Casematerial Stainless steel

OPTIONS CODEMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

0.5,1,2,5,10,15,25,30

Temperature compensa-tion

1b.30°Fto130°F1a.60°Fto160°F1d.-20°Fto130°F1c.0°Fto185°F1j.0°Cto50°C

Internal amplifiers

2u.Unamplified,mV/Voutput

2b.4wire±5Vdc2c.0Vdcto5Vdc2j.4mAto20mA

(three-wire)output

2k.4mAto20mA(two-wire)output11

2n.(2N)4mAto20mA(two-wire)intrinsicallysafe11

2t.0Vdcto10Vdc

Internal amp enhance-ments

3a.Input/outputisolation8

3d.Remotebufferedshuntcalibration

Pressure ports5

5h.1/8-27NPTfemale(2)5a.1/4-18NPTfemale5c.7/16-20UNFfemale

Electrical termination

6a.BendixPTIH-10-6P(orequiv.)6pin(max.120°C)

6e.Integralcable:Teflon(-54°Cto245°C)

6f.Integralcable:PVC(-30°Cto70°C)

6g.Integralcable:Neoprene(-20°Cto80°C)1

6h.Integralcable:Silicone(-54°Cto150°C)

6i.Integralunderwatercable(8m[26ft])(max.80°C)1

6j.1/2-14conduitfittingwith1,5m[5ft]of 4conductorPVCcable

6m.DIN436506q.Moldedintegralcable:

Polyurethane1

6t.Integralcablewithheycospringstrainrelief(1.6m[5.2ft])

Shunt calibration

8a.Precisioninternalresistor6

Special calibration

9a.10point(5up/5down) 20%increments@20°C[68°F]

9b.20point(10up/10down) 10%increments@20°C[68°F]

Wetted diaphragm

10a.316stainlesssteel

Bridge type 11a. Square bridge6

11b. Symmetrical bridge6

11c. Square & symmetrical bridge6

Zero and span adjustment

14b.Topaccesstopots7

14a.Noaccesstopots

Increased line pressure

25a.2000psilinepressure25b.3000psilinepressure25c.5000psilinepressure1

Interfaces 53e.Signaturecalibration6

53t.TEDSIEEE1451.4module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 11: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell•SensingandControl3

Low Range Wet/Wet Differential Pressure Transducer

MOUNTING DIMENSIONSTYPICAL SYSTEM DIAGRAM

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2T

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5V 0Vto5Vor±5V@ 5 mA

0Vto10Vor±10V@5mA

4mAto20mA 4mAto20mA 4mAto20mA

Input power (voltage)

±15Vor26Vdcto32Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 9Vdcto32Vdc 9Vdcto28Vdc

Input power (current)

45mA 40mA 40mA 65mA 4mAto28mA 4mAto24mA

Freq. response (amp)

3000Hz 3000Hz 3000Hz 2500Hz 300Hz 2000Hz

Power supply rejection

60db 60db 60db 60db 60db 60db

Operating temperature

-20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltageprotection

Yes Yes Yes Yes Yes Yes

Short circuit protection

Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector(std)2

A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB No connectionCNoconnectionD(+)OutputECasegroundF No connection

A(+)SupplyB No connectionCNoconnectionD(+)OutputECasegroundF No connection

Wiring code: cable2,3,4

R(+)SupplyBl Output commonG Supply returnW(+)OutputB Shunt cal 1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputB Shunt cal 1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputB Shunt cal 1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputB Shunt cal 1BrShuntcal2

R(+)SupplyBl(+)OutputWCaseground

R(+)SupplyBl(+)OutputWCaseground

*Blackandgreenwiresareinternallyconnected.**PinsBandCareinternallyconnected.***SeeHoneywell’sWebsiteforthemostup-to-dateinformationregardingIntrinsicallysafeapprovals,ref#008-0547-00.

50,8

mm

[2

in] m

ax.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 12: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008766-1-ENIL50GLOMay2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.

Model KZ Low Range Wet/Wet Differential Pressure Transducer

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1. Availability varies according to range.2. Interconnectingshuntcal.1terminalwithshuntcal.2terminal

provides50%(unamplifiedunits),75%(4mAto20mA3-wireunits)or80%(voltageamplifiedunitsoffullscaleoutputforquickcalibration. Shunt calibration comes standard with internal amplifier options2b,2c,2tand2j.

3. O=Orange,Y=Yellow,B=Blue,Bl=Black,R=Red,Br=Brown,W=White,G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

4. Nomatingconnectornecessaryforcableoption.5. Some pressure port options may require axial orientation.6. Onlyavailablewithunamplifiedoption2u.7. Onlyavailablewithamplifiedoptions.8. OnlyavailablewithVdcoutputoptions2b,2c.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Terminationdependent;consultfactory.11. 5000 ohm bridge required.

**Option:alsoavailable,equivalentinchesofwatercolumn,inchesofHGcolumn,mBarorkPaforpressureranges

Note:Unlessotherwisespecifiedonorder,amplifiedunitswith4mAto20mAoutputwillprovide4mAat0psidand20mAatpositivefullscaleand the unit will not operate in the negative direction. An available is to specify4mAatnegativefullscaleand20mAatpositivefullscale.Allampsadd2intohousing.

RANGE CODES

Range Code Available rangesAN ±0.5 psid

AP ±1 psid

AR ±2psid

AT ±5 psid

AV ±10 psid

BJ ±15 psid

BL ±25psid

BM ±30psid

Connector Unamplified

A, B (+)excitation

C, D (-)excitation

E (-)output

F (+)output

WIRING CODES

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 13: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Mid Range Wet/Wet Differential Pressure Transducer

Model Z

DESCRIPTIONModels Z Mid Range Wet/Wet Differential is high accuracy,

bonded foil strain gage transducers designed to accept fluid in

both ports and measure differential pressure ranges of

50 to 750 psid. Standard features such as overload stops and

stainless steel construction provide unit durability in rugged

industrial environments. Each is bi-directional and achieves

accuracies of .25 % to .5 % full scale. The models are available

with extended temperature ranges. Typical applications include

flow measurement, depth sensing, pressure equalization, and

liquid level.

FEATURES• 50 psid to 750 psid

• 0.25% accuracy

• Amplified output available

• Intrinsically safe available (2N option only)10

• CE approved11

POTENTIAL APPLICATIONS• Flow measurement

• Depth sensing

• Pressure equalization

• Liquid level

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 14: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model Z

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid

Accuracy ±0.25 % full scale

Linearity ±0.15 % full scale (typical)

Hysteresis ±0.10 % full scale (typical)

Non-repeatability ±0.05 % full scale (typical)

Output (standard) 2 mV/V (nominal)

Line pressure 1500 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±0.5 % full scale/100 °F

Temperature, effect, span ±0.5 % reading/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 10 Vdc

Excitation (acceptable) Up to 10 Vdc or ac

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance 350 ohm

Shunt calibration data Included

Elec. termination (std) PTIH-10-6P or equivalent (hermetic stainless)

Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe 1500 psi

Pressure port 1/8-27 NPT female (2)

Dead volume 0.25 cu. in

Wetted parts material 17-4 PH stainless steel

Weight 2,3 kg [5 lb]

Case material Stainless steel

OPTION CODES

Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

50, 75, 100, 150, 200, 300, 500, 750

Temperaturecompensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F

1g. 70 °F to 325 °F1h. 70 °F to 400 °F 1i. -65 °F to 250 °F1j. 0 °C to 50 °C1m. -25 °C to 110 °C

Internal amplifiers

2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA (3-wire) output2k. 4 mA to 20 mA (two-wire) output

2n. (2N) 4 mA to 20 mA (two-wire) intrinsically safe2t. 0 Vdc to 10 Vdc2u. Unamplified, mV/V output

Internal amp enhancements

3a. Input/output isolation8 3d. Remote buffered shunt calibration

Pressure ports5

5h. 1/8-27 NPT female (2)5c. 7/16-20 UNF female

Electricaltermination

6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)

6b. MS type connector1

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C)1

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (8m [26 ft]) (max. 80 °C)1

6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable

Shunt calibration 8a. Precision internal resistor7

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C

9b. 20 point (10 up/10 down) 10% increments @ 20 °C

Wetted diaphragm

17-4 PH Stainless steel10a. 316 stainless steel

Bridge type 11a. Square bridge6

11b. Symmetrical bridge6

11c. Square & symmetrical bridge6

Zero & span adjustment

14a. No access to pots 14b. Top access to pots 6

Interfaces 53e. Signature calibration6

53t. TEDS IEEE 1451.4 module9RANGE CODES

Range Code

Available ranges

RangeCode

Available ranges

BN ±50 psid CL ±200 psid

BP ±75 psid CP ±300 psid

BR ±100 psid CR ±500 psid

CJ ±150 psid CT ±750 psid

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 15: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell • Sensing and Control 3

Mid Range Wet/Wet Differential Pressure Transducer

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA

0 V to 10 V or ±10 V @ 5 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 V or 26 Vdc to 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db

Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse voltage protection

Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)2

A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1

F Shunt cal 2

A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1

F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1

F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1

F Shunt cal 2

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1

Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1

Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1

Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1

Br Shunt cal 2

R (+) SupplyBl (+) OutputW Case ground

R (+) SupplyBl (+) OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00.

MOUNTING DIMENSIONS AND CHARACTERISTICS

50,8

mm

[2

in] m

ax.

TyPICAL SySTEM DIAGRAMConnector Unamplified

A, B (+) excitation

C, D (-) excitation

E (-) output

F (+) output

WIRING CODES

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 16: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008721-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model Z Mid Range Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURy• DO NOT USE these products as safety or emergency stop

devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION • The information presented in this catalogue is for reference

only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information

is provided in the instructions supplied with each product.Failure to comply with these instructions could result in death or serious injury.

NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal

provides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with inter-nal amplifier options 2b, 2c, 2t and 2j.)

3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.

4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent;

consult factory.11. Internal amp and termination dependent; consult factory.12 5000 ohm bridge required.

Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available is to specify 4 mA at negative full scale and 20 mA at positive alternative/full scale. All amps add 2 in to housing.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 17: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Mid Range Wet/Wet Differential Pressure Transducer

Model A-5

FEATURES• 0.5% accuracy

• 50 psid to 750 psid

• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc

to 10 Vdc output

• Intrinsically safe available (2N option only)10

• CE approved11

DESCRIPTIONModel A-5 mid-range Wet/Wet Differential is a bonded foil strain

gage transducers designed to accept fluid in both ports and

measure differential pressure ranges from 50 psid to 750 psid.

Standard features such as overload stops and stainless steel

construction provide unit durability in rugged industrial environ-

ments. Each is bi-directional and achieves accuracies of 0.5 %

full scale.

A variety of standard options are available with the Model A-5 in-

cluding the traditional removable pressure adaptors for cleaning

purposes, extended temperature ranges, alternative pressure

ports, internal amplifiers options, and electrical terminations.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 18: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model A-5

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid

Accuracy ±0.5 % full scale

Linearity ±0.25 % full scale (typical)

Hysteresis ±0.13 % full scale (typical)

Non-repeatability ±0.07 % full scale (typical)

Output (standard) 2 mV/V (nominal)

Line pressure 1500 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±0.75 % full scale/100 °F

Temperature, effect, span ±1.0 % reading/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 10 Vdc

Excitation (acceptable) Up to 10 Vdc or ac

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance 350 ohm

Shunt calibration data Included

Elec. termination (std) Bendix PTIH-10-6P or equivalent (hermetic stainless)

Mating connector (not incl.) Bendix PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe 1500 psi

Pressure port 1/8-27 NPT female (2)

Dead volume 0.25 cu. in

Wetted parts material 17-4 PH stainless steel

Weight 2,3 kg [5 lb]

Case material Stainless steel

OPTION CODES

Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

50, 75, 100, 150, 200, 300, 500, 750

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F

1j. 0 °C to 50 °C 1i. -65 °F to 250 °F6

1m. -25 °C to 110 °C1g. 70 °F to 325 °F6

1h. 70 °F to 400 °F6

Internal amplifiers

2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA

(3-wire) output2k. 4 mA to 20 mA

(two-wire) output12

2n. (2N) 4 mA to 20 mA (2 wire) intrin-sically safe12

2t. 0 Vdc to 10 Vdc2u. Unamplified, mV/V

output

Internal ampenhancements

3a. Input/output isolation8

3d. Remote buffered shunt calibration

Pressure ports5 5h. 1/8-27 NPT female (2)5c. 7/16 in -20 UNF female (per MS33656E4)

Electrical termination

6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)

6b. MS type connector to mate MS3106-14S-6S (max. 160 °F)1

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C) 1

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (8 m [26 ft]) (max. 80°C)1

6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable

Shunt calibration

8a. Precision internal resistor 6

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down) 10% increments @ 20 °C

Wetted diaphragm

17-4 PH stainless steel10a. 316 stainless steel

Bridge type 11a. Square bridge6

11b. Symmetrical bridge6

11c. Square & symmetrical bridge6

Zero & span adjustment

14a. No access14b. Top access6

O-ring seals 26a. Metal26b. Vi-Ton26c. Teflon

Interfaces 53e. Signature calibration6

53t. TEDS IEEE 1451.4 module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 19: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell • Sensing and Control 3

Mid Range Wet/Wet Differential Pressure Transducer

TYPICAL SYSTEM DIAGRAM

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA

0 V to 10 V or ±10 V @ 5 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 V or 26 Vdc to 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db

Operating temperature -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse volt. protection Yes Yes Yes Yes Yes Yes

Short circuit protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)2

A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1

F Shunt cal 2

A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1

F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1

F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1

F Shunt cal 2

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

Wiring code: cable2,3,4

R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1

Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1

Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1

Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1

Br Shunt cal 2

R (+) SupplyBl (+) OutputW Case ground

R (+) SupplyBl (+) OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00.

MOUNTING DIMENSIONS AND CHARACTERISTICS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 20: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008722-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model A-5 Mid Range Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the

product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

RANGE CODES

Range Code

Available ranges

RangeCode

Available ranges

BN ±50 psid CL ±200 psid

BP ±75 psid CP ±300 psid

BR ±100 psid CR ±500 psid

CJ ±150 psid CT ±750 psid

NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal

provides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.

3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.

4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent; consult

factory.11. Internal amp and termination dependent; consult factory.12. 5000 ohm bridge required.

Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to housing.

Connector Unamplified

A, B (+) excitation

C, D (-) excitation

E (-) output

F (+) output

WIRING CODES

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 21: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

High Range Wet/Wet Differential Pressure Transducer

Model Z

DESCRIPTIONThe Z High Range Wet/Wet transducers are engineered to

measure differential pressures as great as 10k psid and achieve

accuracy of 0.25 % full scale. Each is bi-directional and accepts

fluid in both ports. 17-4 PH stainless steel ensures durability of

these bonded foil strain gage units under harsh industrial condi-

tions.

A variety of standard options are available with the Model Z in-

cluding choice of pressure adaptors, alternative pressure ports,

internal amplifiers options, and electrical terminations.

FEATURES• 0.25% accuracy

• 2000 psid to 10000 psid

• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc

to 10 Vdc output

• Intrinsically safe available (2N option only)10

• CE approved11

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 22: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model Z

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 2000, 3000, 5000, 7500, 10000 psid

Accuracy ±0.25 % full scale

Linearity ±0.15 % full scale (typical)

Hysteresis ±0.10 % full scale (typical)

Non-repeatability ±0.05 % full scale (typical)

Output (standard) 2 mV/V (nominal)

Line pressure 2000 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±0.5 % full scale/100 °F

Temperature, effect, span ±0.5 % reading/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 10 Vdc

Bridge resistance 350 ohm (nominal)

Shunt calibration data Included

Elec. termination (std) PTIH-10-6P or equivalent (hermetic stainless)

Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe number here

2000 psid to 3000 psid 100% over capacity

5000 psid to 10000 psid 50% over capacity

Pressure port 1/4-18 NPT female (2)

Wetted parts material 17-4 PH stainless steel

Case material Stainless steel

OPTION CODES

Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor- ship for updated listings.

Pressure ranges (psid)

2000, 3000, 5000, 7500, 10000

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F

1g. 70 °F to 325 °F6

1h. 70 °F to 400 °F6

1i. -65 °F to 250 °F6

1j. 0 °C to 50 °C1m. -25 °C to 110 °C

Internal amplifiers

2u. Unamplified, mV/V output

2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2t. 0 Vdc to 10 Vdc2j. 4 mA to 20 mA

(three-wire) output

2k. 4 mA to 20 mA (two-wire) output12

2n. (2N) 4 mA to 20 mA (two-wire) intrinsically safe12

Pressure ports 5 5a. 1/4-18 NPT female5c. 7/16-20 UNF female

Electrical termination

6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)

6b. MS type connec-tor to mate with MS3106-14S-6S (max. 160 °F)1

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C)1

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (8m [26 ft]) (max. 80 °C)1

6j. 1/2-14 conduit fit-ting with 1,5 m [5 ft] of 4 conductor PVC cable

Shunt calibration

8a. Precision internal resistor8

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down) 10% increments @ 20 °C

Wetted diaphragm

17-4 PH stainless steel

Bridge type 11a. Square bridge6

11c. Square & symmetrical bridge6

11b. Symmetrical bridge6

Zero and span adjustment

14b. Top access to pots 7

14a. No access to pots

O ring seals 26a. Metal

Interfaces 53e. Signature calibration6

53t. TEDS IEEE 1451.4 module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 23: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell • Sensing and Control 3

High Range Wet/Wet Differential Pressure Transducer

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA

0 V to 10 V or ±10 V @ 5 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 V or 26 Vdc to 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db

Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse voltage protection

Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)2

A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl (+) OutputW Case ground

R (+) SupplyBl (+) OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.

TyPICAL SySTEM DIAgRAM

4-18

MOUNTINg DIMENSIONS AND CHARACTERISTICS

For reference only

2X

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 24: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008718-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model Z High Range Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINgPERSONAL INJURy

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINgMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

RANgE CODES

Range Code Available rangesDL ±2000 psid

DN ±3000 psid

DR ±5000 psid

DT ±7500 psid

DV ±10000 psid

NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-

vides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.

3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.

4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent; consult

factory.11. Internal amp and termination dependent; consult factory.12. 5000 ohm bridge required.

Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An avail-able alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to amplifier housing.

Connector Unamplified

A, B (+) excitation

C, D (-) excitation

E (-) output

F (+) output

WIRINg CODES

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 25: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

High Range Wet/Wet Differential Pressure Transducer

Model A-5

DESCRIPTIONThe A-5 high range Wet/Wet transducers are engineered to mea-

sure differential pressures as great as 10k psid and achieves

accuracy of 0.5 % full scale. Each series is bi-directional and

accepts fluid in both ports. 17-4 PH stainless steel ensures dura-

bility of these bonded foil strain gage units under harsh industrial

conditions.

A variety of standard options are available with the Model A-5 in-

cluding choice of pressure adaptors, alternative pressure ports,

internal amplifiers options, and electrical terminations.

FEATURES• 0.5% accuracy

• 2000 psid to 10000 psid

• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc

to 10 Vdc output

• Intrinsically safe available (2N option only)10

• CE approved11

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 26: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model A-5

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 2000, 3000, 5000, 7500, 10000 psid

Accuracy ±0.5 % full scale

Linearity ±0.25 % full scale (typical)

Hysteresis ±0.13 % full scale (typical)

Non-repeatability ±0.07 % full scale (typical)

Output (standard) 2 mV/V (nominal)

Line pressure 2000 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±0.75 % full scale/100 °F

Temperature, effect, span ±1.0 % reading/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 10 Vdc

Bridge resistance 350 ohm (nominal)

Shunt calibration data Included

Elec. termination (std) PTIH-10-6P or equivalent (hermetic stainless)

Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe2000 psid to 3000 psid

100% over capacity

Overload-safe5000 psid to 10000 psid

50% over capacity

Pressure port 1/4-18 NPT female (2)

Wetted parts material 17-4 PH stainless steel

Case material Stainless steel

OPTION CODES

Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

2000, 3000, 5000, 7500, 10000

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F

1i. -65 °F to 250 °F1j. 0 °C to 50 °C1m. -25 °C to 110 °C 1g. 70 °F to 325 °F1h. 70 °F to 400 °F

Internal amplifiers

2u. Unamplified, mV/V output2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA (3-wire) output

2k. 4 mA to 20 mA (two-wire) output12

2n. (2N) 4 mA to 20 mA (two-wire) intrinsically safe12

2t. 0 Vdc to 10 Vdc

Internal amp enhancements

3a. Input/output isolation6 3d. Remote buffered shunt calibration

Pressure ports5 5a. 1/4-18 NPT female5c. 7/16-20 UNF female

Electrical termination

6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 120 °C)

6b. MS type connec-tor 1

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C)1

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (8m [26 ft]) (max. 80°C)1

6j. 1/2-14 conduit fit-ting with 1,5 m [5 ft] of 4 conductor PVC cable

Shunt calibration 8a. Precision internal resistor7

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down) 10% increments @ 20 °C

Wetted diaphragm

17-4 PH stainless steel

Bridge type 11a. Square bridge11c. Square & symmetrical bridge11b. Symmetrical bridge

Zero and span adjustment

14b. Top access to pots8

14a. No access to pots

O ring seals 26a. Metal

Interfaces53e. Signature calibration53t. TEDS IEEE 1451.4 module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 27: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell • Sensing and Control 3

High Range Wet/Wet Differential Pressure Transducer

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage out-put: Option 2b

Voltage out-put: Option 2c

Voltage out-put: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA

0 V to 10 V or ±10 V @ 5 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 V or 26 Vdc to 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc

9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. response (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db

Operating temperature -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse volt. protection Yes Yes Yes Yes Yes Yes

Short circuit protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)2

A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl (+) OutputW Case ground

R (+) SupplyBl (+) OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00.

TyPICAL SySTEM DIAgRAM

MOUNTINg DIMENSIONS AND CHARACTERISTICS

For reference onlyNOT TO SCALE

1/4-18 NPT female

2X

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 28: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008719-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model A-5 High Range Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINgPERSONAL INJURy

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINgMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

RANgE CODES

Range Code Available ranges

DL ±2000 psid

DN ±3000 psid

DR ±5000 psid

DT ±7500 psid

DV ±10000 psid

NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-

vides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.)

3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.

4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent; consult

factory.11. Internal amp and termination dependent; consult factory.12. 5000 ohm bridge required.

Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to amplifier housing.

Connector Unamplified

A, B (+) excitation

C, D (-) excitation

E (-) output

F (+) output

WIRINg CODES

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 29: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

DP Low Range Two Wire Wet/Wet Differential Pressure Transducer

Model 420

DESCRIPTIONThe Model 420 DP two-wire low range differential pressure

transmitters utilize supply voltage of 9 Vdc to 32 Vdc to produce

a two-wire 4 mA to 20mA process loop output for differential

pressure ranges of 2 psid to 25 psid. A minimum full scale ac-

curacy of 0.5% is achieved. Stainless steel construction ensures

durability under harsh, industrial conditions and includes zero

and span adjustments. A variety of options are available with

the Model 420 including choice of pressure adaptors and pres-

sure ports.

FEATURES• 0.5% accuracy

• 2 psid to 25 psid range

• Stainless steel

• Intrinsically safe available (2N option only)4

• CE approved5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 30: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model 420

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 2, 5, 10, 15, 25 psid

Accuracy ±0.5 % full scale

Linearity ±0.25 % full scale (typical)

Hysteresis ±0.13 % full scale (typical)

Non-repeatability ±0.07 % full scale (typical)

Output (standard) 4 mA to 20 mA

Line pressure 1500 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]

Temperature, compensated -1 °C to 54 °C [30 °F to 130 °F]

Temperature, effect, zero ±1.0 % full scale/100 °F

Temperature, effect, span ±1.0 % reading/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 15 Vdc to 40 Vdc

Max. load resistance 500 ohm

Shunt calibration data Included

Elec. termination (std) PTIH-10-6P or equiv. (Hermetic stainless)

Mating conn. (not incl) PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe 1500 psi either side

Pressure port 1/8-27 NPT female

Wetted parts material 316 stainless steel

Case material Stainless steel

RANGE CODES

Range Code Available ranges

AR 2 psid

AT 5 psid

AV 10 psid

BJ 15 psid

BL 25 psid

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

2, 5, 10, 15, 25

Temperature compensation

1b. 30 °F to 130 °F1a. 60 °F to 160 °F1c. 0 °F to 185 °F

Internal amplifiers

2k. 4 mA to 20 mA (two wire)

Internal amplifier enhancements

3d. Remote buffered shunt calibration

Pressure ports2 5h. 1/8-27 NPT female5c. 7/16-20 UNF female

Electrical termination

6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C1)

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (max. 80°C)1

6j. 1/2-14 conduit fit-ting with 1,5 m [5 ft] 4 conductor PVC cable

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C

9b. 20 point (10 up/10 down) 20% increments @ 20 °C

Wetted diaphragm

10a. 316 stainless steel

Increased line pressure

25a. 2000 psi line pressure25b. 3000 psi line pressure12a. 5000 psi line pressure

O ring seals 26c. Teflon

WIRING CODES

Connector Two-wire current 4 mA to 20 mA

A (+) supply

B no connection

C no connection

D (+) output (4 mA to 20 mA)

E Case ground

F no connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 31: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008708-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 420 DP Low Range Two Wire Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

NOTES1. Availability varies according to range.2. Some pressure port options may require axial orientation.3. Range dependent; consult factory. Termination dependent; consult

factory.4. Internal amp and termination dependent; consult factory.

Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale.

WARNINGPERSONAL INJURY

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

TYPICAL SYSTEM DIAGRAM

MOUNTING DIMENSIONS AND CHARACTERISTICS

For reference only

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 32: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

DP Mid Range Two Wire Wet/Wet Differential Pressure Transducer

Model 420

DESCRIPTIONThe Model 420 DP two-wire mid range differential pressure

transmitters utilize supply voltage of 9 Vdc to 32 Vdc to produce

a two-wire 4 mA to 20mA process loop output for differential

pressure ranges of 50 psid to 750 psid. A minimum full scale ac-

curacy of 0.5% is achieved. Stainless steel construction ensures

durability under harsh, industrial conditions and includes zero

and span adjustments. A variety of options are available with

the Model 420 including choice of pressure adaptors and pres-

sure ports.

FEATURES• 0.5% accuracy

• 50 psid to 750 psid range

• Stainless steel

• Intrinsically safe available (2N option only)4

• CE approved5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 33: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model 420

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid

Accuracy ±0.5 % full scale

Linearity ±0.25 % full scale (typical)

Hysteresis ±0.13 % full scale (typical)

Non-repeatability ±0.07 % full scale (typical)

Output (standard) 4 mA to 20 mA

Line pressure 1500 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]

Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±1.0 % full scale/ 38 °C [100 °F]

Temperature, effect, span ±1.0 % reading/ 38 °C [100 °F]

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 15 Vdc to 40 Vdc

Maximum load resistance 500 ohm

Shunt calibration data Included

Elec. termination (std) PTIH-10-6P or equiv. (Hermetic stainless)

Mating conn. (not incl) PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe 1500 psi either side

Pressure port 1/8-27 NPT female (2)

Wetted parts material 17-4 PH stainless steel

Case material Stainless steel

RANGE CODES

RangeCode

RANGE RangeCode

RANGE

BN 50 psid CL 200 psid

BP 75 psid CP 300 psid

BR 100 psid CR 500 psid

CJ 150 psid CT 750 psid

OPTION CODES

Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

50, 75, 100, 150, 200, 300, 500, 750

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F

1c. 0 °F to 185 °F

Internal amplifiers 2k. 4 mA to 20 mA (two wire)

Internal amplifier enhancements

3d. Remote buffered shunt calibration

Pressure ports2 5h. 1/8-27 NPT female5c. 7/16-20 UNF female

Electrical termination

6a. Bendix PTIH-10-6P (or equiv.) 6 pin (250 °F)

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C)1

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (8 m [26 ft]) (max. 80 °C)1

6j. 1/2-14 conduit fitting with 1,5 m [5 ft] 4 conductor PVC cable

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C [68 °F]

9b. 20 point (10 up/10 down) 20% increments @ 20 °C [68 °F]

Wetted diaphragm

17-4 stainless steel

O-ring seals 26a. Metal26c. Teflon

WIRING CODES

Connector/ two-wire current/ 4 mA to 20 mA

A (+) supply

B No connection

C No connection

D (+) output (4 mA to 20 mA)

E Case ground

F No connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 34: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008709-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 420 DP Mid Range Two Wire Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

NOTES1. Availability varies according to range.2. Some pressure port options may require axial orientation.3. Range dependent; consult factory. Termination dependent; consult

factory.4. Internal amp and termination dependent; consult factory. Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale.

WARNINGPERSONAL INJURY

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

TYPICAL SYSTEM DIAGRAM

1/8-27

MOUNTING DIMENSIONS AND CHARACTERISTICS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 35: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

DP High Range Two Wire Wet/Wet Differential Pressure Transducer

Model 420

DESCRIPTIONThe Model 420 DP two-wire high range differential pressure

transmitters utilize supply voltage of 9 Vdc to 32 Vdc to produce

a two-wire 4 mA to 20mA process loop output for differential

pressure ranges of 2000 psid to 10000 psid. A minimum full

scale accuracy of 0.5% is achieved. Stainless steel construc-

tion ensures durability under harsh, industrial conditions and

includes zero and span adjustments. A variety of options are

available with the Model 420 including choice of pressure adap-

tors and pressure ports.

FEATURES• 0.5% accuracy

• 2000 psid to 10000 psid range

• Stainless steel

• Intrinsically safe available (2N option only)4

• CE approved5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 36: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model 420

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 2000, 3000, 5000, 7500, 10000 psid

Accuracy ±0.5 % full scale

Linearity ±0.25 % full scale (typical)

Hysteresis ±0.13 % full scale (typical)

Non-repeatability ±0.07 % full scale (typical)

Output (standard) 4 mA to 20 mA

Line pressure 1500 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]

Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±1.0 % full scale/38 °C [100 °F]

Temperature, effect, span ±1.0 % reading/38 °C [100 °F]

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 15 Vdc to 40 Vdc

Max. load resistance 500 ohm

Shunt calibration data Included

Elec. termination (std) PTIH-10-6P or equiv. (Hermetic stainless)

Mating conn. (not incl) PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe 50% over capacity

Pressure port 1/4-18 NPT female (2)

Wetted parts material 17-4 PH stainless steel

Case material Stainless steel

RANGE CODES

Range Code Available ranges

DL 2000 psid

DN 3000 psid

DR 5000 psid

DT 7500 psid

DV 10000 psid

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

2000, 3000, 5000, 7500, 10000

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F

Internal amplifiers

2k. 4 mA to 20 mA (two wire)

Internal amplifier enhancements

3d. Remote buffered shunt calibration

Pressure ports 5h. 1/4-18 NPT female5c. 7/16- 20 UNF female

Electricaltermination

6a. Bendix PTIH-10-6P (or equivalent) 6 pin (max. 121 °C)

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C)1

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (8 m [26 ft]) (max. 80 °C)1

6j. 1/2-14 conduit fitting with 1,5 m [5 ft] 4 conductor PVC cable

Special calibra-tion

9a. 10 point (5 up/5 down) 20% increments @ 20 °C [68 °F]

9b. 20 point (10 up/10 down) 20% increments @ 20 °C [68 °F]

Wetted diaphragm

17-4 PH stainless steel

O-ring seals 26a. Metal

WIRING CODES

Connector Two-wire current 4 mA to 20 mA

A (+) supply

B no connection

C no connection

D (+) output (4 mA to 20 mA)

E Case ground

F no connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 37: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008710-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 420 DP High Range Two Wire Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

TYPICAL SYSTEM DIAGRAM

MOUNTING DIMENSIONS AND CHARACTERISTICS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 38: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Subminiature Wet/Wet Differential Pressure Transducer

Model P-30-P

DESCRIPTIONThe Model P-30-P, wet/wet differential pressure transducer, is a

subminiature unit which is uniquely suited to aerospace, chemi-

cal or nuclear applications. Features include small size, bidirec-

tional overload protection, wide temperature compensation, and

high natural frequencies.

FEATURES• 0.3%accuracy

• 5psidto2000psid

• Highfrequency

• Lightweight

• Compactdesign

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 39: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2Honeywell•SensingandControl

Model P-30-P

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges (psid) 5,10,15,25,50,75,100,150,200,300,500,750,1000,2000

Accuracy ±0.3%fullscale

Linearity ±0.2%fullscale(typical)

Hysteresis ±0.1%fullscale(typical)

Non-repeatability ±0.1%fullscale(typical)

Output (standard)

5psidto25psid 100mV(nominal)

50psidto2000psid 2mV/V(nominal)

Linepressure

5psidto25psid 250psi

50psidto2000psid 500psior2Xfullscale(whicheverishigher)upto2000psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 16°Cto71°C[60°Fto160°F]

Temperature effect, zero

5psidto25psid ±2.0%fullscale/100°F

50psidto2000psid ±1.0%reading/100°F

Temperature effect, span

5psidto25psid ±2.0%fullscale/100°F

50psidto2000psid ±1.0%reading/100°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype

5psidto25psid Bonded semiconductor

50psidto2000psid Bonded foil

Excitation (calibration) 10Vdc

Bridge resistance

5psidto25psid 500ohm

50psidto2000psid 350ohm

Shuntcalibrationdata Included

Elec. termination (std) Tefloncable1.5m[5ft]

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe Max. line pressure either side

Pressure port 1/8-27NPTmale:7/16hex

Wetted parts material 17-4PHstainlesssteel

Casematerial Stainlesssteel

RANGE CODES

Range Code

Range Range Code

Range

AT 5psid CJ 150psid

AV 10psid CL 200psid

BJ 15psid CP 300 psid

BL 25psid CR 500psid

BN 50psid CT 750psid

BP 75psid CV 1000psid

BR 100psid DL 2000psid

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

5,10,15,25,50,75,100,150,200,300,500,750,1000,2000

Temperature compensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F

1e.-20°Fto200°F1f.70°Fto250°F1g.0°Cto50°C

Internal amplifiers

2u.Unamplified,mV/Voutput

Pressure ports 5i.1/8-27NPTmale5d.7/16-20UNFmale(perMS33656-E4)

Electrical termination

6e.Integralcable:Teflon(-54°Cto245°C)6i.Integralunderwatercable(8m[26ft])(max.

80°C)1

WIRING CODES

Connector/unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 40: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008711-1-ENIL50GLOMay2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.

Model P-30-P Subminiature Wet/Wet Differential Pressure Transducer

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

TYPICAL SYSTEM DIAGRAM

For reference only

2X

NOTES1.Availabilityvariesaccordingtorange. For long cable runs or electrically noisy environments an amplified sensor or locally mounted amplifier is often preferred.

MOUNTING DIMENSIONS AND CHARACTERISTICS

Range (psid) Order codes D mm [in] L mm [in]

5to25 BD311 28,7mm[1.13] 35,6mm[1.4]

50to500 BD312 28,7mm[1.13] 35,6mm[1.4]

750to2000 BD312 35,1mm[1.38] 40,6mm[1.6]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 41: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Aerospace Pressure TransducersModel AS25D

DESCRIPTIONModel AS25D wet/wet differential pressure sensor features

welded stainless steel diaphragms on both ports. All units

are able to meet MIL-45208 and traceability requirements.

FEATURES• 0.3% accuracy

• Lightweight

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 42: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model AS25D

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 15 psid to 2000 psid

Accuracy ±0.3 %

Non-linearity ±0.2 % full scale (typical)

Hysteresis ±0.1 % full scale (typical)

Output 2 mV/V nominal

Resolution Infinite

WIRINg CODES

Cable/unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 149 °C [-65 °F to 300 °F]

Temperature, compensated -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, effect, zero 0.01 % full scale/ °F

Temperature, effect, span 0.01 % reading/ °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Excitation (calibration) 10 Vdc

Bridge resistance 350 ohm

Electrical termination (std) Shielded cable

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Fluids compatible with 17-4 PH stainless steel

Pressure port 7/16-20 per MS33656-E4

Wetted parts material 17-4 PH stainless steel

Weight Consult factory

Case material Stainless steel

RANgE CODES

RangeCode

Ranges RangeCode

Ranges

BJ 15 psid CP 300 psid

BL 25 psid CR 500 psid

BN 50 psid CT 750 psid

BP 75 psid CV 1000 psid

BR 100 psid DJ 1500 psid

CJ 150 psid DL 2000 psid

CL 200 psid

TyPICAL SySTEM DIAgRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 43: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008712-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model AS25D Aerospace Pressure Transducers

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINgPERSONAL INJURy

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINgMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

Range (psid) ØD mm [in] L mm [in]

15, 25 28,7 mm [1.13] 35,6 mm [1.4]

50, 75, 100, 150, 200, 300, 500

28,7 mm [1.13] 35,6 mm [1.4]

750, 1000, 1500, 2000

35,1 mm [1.38] 40,6 mm [1.6]

MOUNTINg DIMENSIONS AND CHARACTERISTICS

2X-E4

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 44: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

FM Approved Low Range Wet/Wet Differential Pressure Transmitter

Model 911FMD

DESCRIPTIONThe two-wire Factory Mutual Approved Model 911FM transmitter

has stainless steel diaphragms for use with liquid, gas, or vapors

in hazardous environments. These transducers are corrosion

and shock resistant, as well as reverse polarity protected. The

two-wire, 4 mA to 20 mA current output permits long cable runs

with a high signal-to-noise ratio. This model is constructed with

stainless steel, sealed hermetically.

FEATURES• 0.25%accuracy

• 2psidto25psid

• FactoryMutualapproved

• 4mAto20mAtwo-wire(standard)

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 45: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2Honeywell•SensingandControl

Model 911FMD

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 2,5,10,15,25psid

Accuracy ±0.25%fullscale

Linearity ±0.15%fullscale(typical)

Hysteresis ±0.10%fullscale(typical)

Non-repeatability ±0.05%fullscale(typical)

Output(standard) 4 mA to 20 mA

Max. line pressure 1500psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating 18°Cto82°C[0°Fto180°F]

Temperature, compensated -1°Cto54°C[30°Fto130°F]

Temperature, effect, zero ±1.2%fullscale/100°F

Temperature, effect, span ±1.2%reading/100°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 15Vdcto50Vdc

Shuntcalibrationdata Included

Elec.termination(std) 22 GA cable with case ground 609,6mm[2ft],1/2NPTto14NPT

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe(eitherside) 1500psi

Pressure port 1/8-27NPTfemale

Wetted parts material 316stainlesssteel

Casematerial Stainlesssteel

RANGE CODES

Range Code Available ranges

AR 2 psid

AT 5psid

AV 10 psid

BJ 15psid

BL 25psid

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

2,5,10,15,25

Temperature compensation

1b.30°Fto130°F

Internal amplifiers

2k.4mAto20mA(two-wire)

Pressure ports 5h.1/8-27NPTfemale

Electrical termination

6j. 22 GA cable with case ground 609,6 mm [2ft],1/2NPTto14NPT

Special calibration

9a.10point(5up/5down)20%increments@20°C[68°F]

9b.20point(10up/10down)10%increments@20°C[68°F]

Wetted diaphragm

10a.316stainlesssteel

WIRING CODES

Cable/ two-wire current/ 4 mA to 20 mA

Red (+)supply

Black (+)output(4mAto20mA)

White Caseground

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 46: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008705-1-ENIL50GLOMay 2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.

Model 911FMD FM Approved Low Range Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

TYPICAL SYSTEM DIAGRAM

MOUNTING DIMENSIONS AND CHARACTERISTICS

Mounting hole1/4-28 NPT x 5/16 in DP2 each

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 47: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

FM Approved Mid Range Wet/Wet Differential Pressure Transducer

Model 911FMD

DESCRIPTIONThe two-wire Factory Mutual Approved Model 911FM transmitter

has stainless steel diaphragms for use with liquid, gas, or vapors

in hazardous environments. These transducers are corrosion

and shock resistant, as well as reverse polarity protected. The

two-wire, 4 mA to 20 mA current output permits long cable runs

with a high signal-to-noise ratio. This model is constructed with

stainless steel, sealed hermetically.

FEATURES• 0.25%accuracy

• 50psidto750psid

• FactoryMutualapproved

• 4mAto20mAtwo-wire(standard)

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 48: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2Honeywell•SensingandControl

Model 911FMD

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 50,75,100,150,200,300,500,750psid

Accuracy ±0.25%fullscale

Linearity ±0.15%fullscale(typical)

Hysteresis ±0.10%fullscale(typical)

Non-repeatability ±0.05%fullscale(typical)

Output(standard) 4 mA to 20 mA

Line pressure 1500psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating 18°Cto82°C[0°Fto180°F]

Temperature, compensated 16°Cto71°C[60°Fto160°F]

Temperature, effect, zero ±1.2%fullscale/38°C[100°F]

Temperature, effect, span ±1.2%reading/38°C[100°F]

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 15Vdcto50Vdc

Shuntcalibrationdata Included

Elec.termination(std) 22 GA cable with case ground 609,6 mm[2ft],1/2-14NPT

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe(eitherside) 1500psi

Pressure port 1/8-27NPTfemale

Wetted parts material 17-4PHstainlesssteel

Casematerial Stainlesssteel

WIRINg CODES

CAbLE/ TWO-WIRE CURRENT/ 4 MA TO 20 MA

Red (+)supply

black (+)output(4mAto20mA)

White Caseground

RANgE CODES

RangeCode

Available ranges

RangeCode

Available ranges

bN 50psid CL 200 psid

bP 75psid CP 300psid

bR 100 psid CR 500psid

CJ 150psid CT 750psid

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

50,75,100,150,200,300,500,750

Temperature compensation

1b. 60 °F to 160 °F

Internal amplifiers

2k.4mAto20mA(two-wire)

Pressure ports 5h.1/8-27NPTfemale(2)

Electrical termination

6j. 22 GA cable with case ground 609, 6mm[2ft],1/2NPTto14NPT

Special calibration

9a.10point(5up/5down) 20%increments@20°C[68°F]

9b.20point(10up/10down) 10%increments@20°C[68°F]

Wetted diaphragm

17-4PHstainlesssteel

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 49: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008707-1-ENIL50GLOMay 2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.

Model 911FMD FM Approved Mid Range Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINgPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINgMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

MOUNTINg DIMENSIONS AND CHARACTERISTICS

TYPICAL SYSTEM DIAgRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 50: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

FM Approved High Range Wet/Wet Differential Pressure Transducer

Model 911FMD

FEATURES• Factory Mutual approved

• 4 mA to 20 mA two-wire

POTENTIAL APPLICATIONS• Lorem ipsum dolor sit amet, consectetuer adipiscing elit.

• Mauris massa sem, porttitor id, suscipit sed, venenatis nec,

• Nunc ligula. Vestibulum fringilla fringilla sem. Pellentesque

sapien neque, ullamcorper sit amet, id, aliquet at, elit.

• Phasellus euismod pulvinar lectus. Suspendisse ultricies

dapibus tortor.

• Vivamus mattis.

• Curabitur suscipit, neque quis imperdiet adipi

DESCRIPTIONModel 911 FMD Low and Mid Range, Factory Mutual Approved

Wet/Wet Differential transducers are engineered for use in harsh

industrial applications. The two-wire, 4 mA to 20 mA current out-

put permits cable runs up to 10 miles long with a high signal to

noise ratio. This model is constructed with stainless steel, sealed

hermetically.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 51: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model 911FMD

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges (psid) 1000, 2000, 3000, 5000, 7500, 10000

Accuracy ±0.25 % full scale

Linearity ±0.15 % full scale (typical)

Hysteresis ±0.10 % full scale (typical)

Non-repeatability ±0.05 % full scale (typical)

Output (standard) 4 mA to 20 mA

Max. line pressure Full scale capacity +2000 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]

Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±1.2 % full scale/ 38 °C [100 °F]

Temperature, effect, span ±1.2 % reading/ 38 °C [100 °F]

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 15 Vdc to 50 Vdc

Shunt calibration data Included

Electrical termination (std) 22 GA cable with case ground

609,6 mm [2 ft], 1/2-14 NPT

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Liquid

Overload-safe (either side)

1000 to 3000 psid 100 % over capacity

5000 to 10000 psid 50 % over capacity

Pressure port 1/4-18 NPT female (2)

Wetted parts material 17-4 PH stainless steel

Case material Stainless steel

RANGE CODES

Range Code Available ranges

CV 1000 psid

DL 2000 psid

DN 3000 psid

DR 5000 psid

DT 7500 psid

DV 10000 psid

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

1000, 2000, 3000, 5000, 7500, 10000

Temperature compensation

1b. 60 °F to 160 °F

Internal amplifiers

2k. 4 mA to 20 mA (two-wire)

Pressure ports 5a. 1/4-18 NPT female (2)

Electrical termination

6j. 22 GA cable with case ground 609,6 mm [2 ft], 1/2 NPT to 14 NPT

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C [68 °F]

9b. 20 point (10 up/10 down) 10% increments @ 20 °C [68 °F]

Wetted diaphragm

17-4 PH stainless steel

WIRING CODES

CAbLE/ TWO-WIRE CURRENT/ 4 MA TO 20 MA

Red (+) supply

black (+) output (4 mA to 20 mA)

White Case ground

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 52: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008706-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 911FMD FM Approved High Range Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

For reference only

MOUNTING DIMENSIONS AND CHARACTERISTICS

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 53: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

High Line Wet/Wet Differential Pressure Transducer

Model HL-Z

DESCRIPTIONThe High Line Wet/Wet Differential Pressure Model HL-Z is de-

signed to accept extreme line pressures of up to 5000 psi.* This

unique design features standard bonded foil strain gages on

stainless steel. Liquid and gas differential pressures of 50 psid

to 7500 psid are measured within a 0.25 % to 0.50 % full scale

accuracy. Typical applications include flow measurement and

laboratory testing.

FEATURES• Linepressureto5000psi

• 0.25%accuracy

• Intrinsicallysafeavailable(2Noptiononly)10

• CEapproved11

POTENTIAL APPLICATIONS• Flowmeasurement

• Laboratorytesting

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 54: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2Honeywell•SensingandControl

Model HL-Z

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500* psid

Accuracy ±0.25 % full scale

Linearity ±0.15%fullscale(typical)

Hysteresis ±0.10%fullscale(typical)

Non-repeatability ±0.05%fullscale(typical)

Output(standard) 2mV/V(nominal)

Line pressure 2500 psi**

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature, effect, zero ±0.5%fullscale/100°F

Temperature, effect, span ±0.5%reading/100°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10 Vdc

Bridge resistance 350 ohm

Shuntcalibrationdata Included

Elec.termination(std) PTIH-10-6Porequivalent(hermeticstainless)

Matingconnector(notincl.) PT06A-10-6Sorequiv.(AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe

50 psid to 1500 psid 2000 psi

2000 psid to 7500 psid Fullscalecapacity+2000psi

Pressure port 1/4-18NPTfemale(2)

Wetted parts material 17-4 PH stainless steel

Casematerial Stainlesssteel

OPTION CODES

Pressure ranges (psid)

Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 3000, 5000, 7500

Temperature compensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F

1f.70°Fto250°F1i.-65°Fto250°F6

1j.0°Cto50°C1m.-25°Cto110°C

Internal amplifiers

2u.Unamplified,mV/Voutput

2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2t. 0 Vdc to 10 Vdc2j. 4 mA to 20 mA

(threewire)output

2k. 4 mA to 20 mA (twowire)output12

2n.(2N)4mAto20mA(twowire)intrinsically safe12

Internal amp enhancements

3a.Input/outputisolation8

3d. Remote buffered shunt calibration

Pressure ports 5 5a.1/4-18NPTfemale5c.7/16-20UNFfemale

Electrical termination

6a.BendixPTIH-10-6P(orequiv.) 6pin(max.250°F)

6b.MStypeconnec-tor to mate with MS3106-14S-6S(max.160°F)1

6e.Integralcable:Teflon(-54°Cto245°C)

6f.Integralcable:PVC(-30°Cto70°C)

6g.Integralcable:Neoprene(-20°Cto80°C)1

6h.Integralcable:Silicone(-54°Cto150°C)

6i.Integralunderwatercable(8m[26ft]) (max.80°C)1

6j.1/2-14conduitfittingwith1,5m[5ft]of4 conductorPVCcable

Shunt calibration 8a. Precision internal resistor 6

Special calibra-tion

9a.10point(5up/5down) 20%increments@20°C

9b.20point(10up/10down) 10%increments@20°C

Wetted diaphragm 17-4 PH stainless steel

Bridge type 11a.Squarebridge6

11b.Symmetricalbridge6

11c.Square&symmetricalbridge6

Zero and span adjustment

14b. Top access to pots7

14a.Noaccesstopots

Increased line pressure

25b. 3000 psi line pressure25c. 5000 psi line pressure

Interfaces 53e.Signaturecalibration6

53t.TEDSIEEE1451.4module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 55: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell•SensingandControl3

High Line Wet/Wet Differential Pressure Transducer

iNTERNAL AMPLIFIERS

Amplifier specifications

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA

0 V to 10 V or ±10 V @ 5 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15Vor26Vdcto 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60db 60db 60db 60db 60db 60db

Operating temp. -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltage protection Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)2

A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable2,3,4 R(+)SupplyBl Output commonGSupplyreturnW(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl(+)OutputWCaseground

R(+)SupplyBl(+)OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeHoneywell’sWebsiteforthemostup-to-dateinformationregardingIntrinsicallysafeapprovals,ref#008-0547-00.

MOUNTINg DIMENSIONS AND CHARACTERISTICS

Forreferenceonly

2X

TyPICAL SySTEM DIAgRAM

1/4-18

NOTE:Forlongcablerunsorelectronicallynoisyenvironments,anamplifiedsensororlocallymountedamplifierisoftenpreferred.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 56: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008715-1-ENIL50GLOMay 2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.

Model HL-Z High Line Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as beingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedto otherwise by Honeywell in writing; please refer to your orderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINgPERSONAL INJURy

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINgMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.

Failure to comply with these instructions could result in death or serious injury.

RANgE CODES

Range Code

Availableranges

Range Code

Availableranges

BN ±50 psid CT ±750 psid

BP ±75 psid CV ±1000 psid

BR ±100 psid DJ ±1500 psid

CJ ±150 psid DL ±2000 psid

CL ±200 psid DN ±3000 psid

CP ±300 psid DR ±5000 psid

CR ±500 psid DT ±7500 psid

NOTES1.Availabilityvariesaccordingtorange.2. Interconnectingshuntcal.1terminalwithshuntcal.2terminalpro-

vides50%(unamplifiedunits),75%(4mAto20mA3-wireunits)or80%(voltageamplifiedunitsoffullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalamplifieroptions2b,2c,2tand2j.)

3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White,G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

4. Nomatingconnectornecessaryforcableoption.5. Somepressureportoptionsmayrequireaxialorientation.6. Onlyavailablewithunamplifiedoption2u.7. Onlyavailablewithamplifiedoptions.8. OnlyavailablewithVdcoutputoptions2b,2c.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Range dependent; consult factory. Termination dependent; consult

factory.11.Internalampandterminationdependent;consultfactory.12. 5000 ohm bridge required.

Note:Unlessotherwisespecifiedonorder,amplifiedunitswith4mAto20mAoutputwillprovide4mAat0psidand20mAatpositivefullscaleandtheunitwillnotoperateinthenegativedirection.Anavail-ablealternativeistospecify4mAatnegativefullscaleand20mAatpositivefullscale.Allampsadd2intoamplifierhousing.

*NotavailablewithFMapproval** On units > 200 psid the sum of full scale pressure must be <= 9500

psi, on units < 200 psid consult factory

Connector Unamplified

A, B (+)excitation

C, D (-)excitation

E (-)output

F (+)output

WIRINg CODES

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 57: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

High Line Wet/Wet Differential Pressure Transducer

Model HL-A-5

DESCRIPTIONThe High Line Wet/Wet Differential Pressure Model HL-A-5 is de-

signed to accept extreme line pressures of up to 5000 psi.* This

unique design features standard bonded foil strain gages on

stainless steel. Liquid and gas differential pressures of 50 psid

to 7500 psid are measured within a 0.50 % full scale accuracy.

A variety of standard options are available with the Model

HL-A-5 including the traditional removable pressure adaptors

for cleaning purposes, extended temperature ranges, alterna-

tive pressure ports, internal amplifiers options, and electrical

terminations.

FEATURES• 0.5 % accuracy

• Line pressure to 5000 psi

• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc

to 10 Vdc output

• Intrinsically safe available (2N option only)10

• CE approved11

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 58: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model HL-A-5

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500* psid

Accuracy ±0.5 % full scale

Linearity ±0.25 % full scale (typical)

Hysteresis ±0.13 % full scale (typical)

Non-repeatability ±0.07 % full scale (typical)

Output (standard) 2 mV/V (nominal)

Line pressure 2500 psi**

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±0.75 % full scale/100 °F

Temperature, effect, span ±1 % reading/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 10 Vdc

Bridge resistance 350 ohm

Shunt calibration data Included

Elec. termination (std) PTIH-10-6P or equivalent (hermetic stainless)

Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe

50 psid to 1500 psid 2000 psi

2000 psid to 7500 psid Full scale capacity + 2000 psi

Pressure port 1/4-18 NPT female

Wetted parts material 17-4 PH stainless steel

Case material Stainless steel

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 3000, 5000, 7500

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F

1f. 70 °F to 250 °F1i. -65 °F to 250 °F6

1j. 0 °C to 50 °C1m. -25 °C to 110 °C

Internal amplifiers

2u. Unamplified, mV/V output

2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2t. 0 Vdc to 10 Vdc2j. 4 mA to 20 mA

(three wire) output

2k. 4 mA to 20 mA (two wire) output12

2n. (2N) 4 mA to 20 mA (two wire) intrinsically safe12

Internal amp enhancements

3a. Input/output isolation8

3d. Remote buffered shunt calibration

Pressure ports 5 5a. 1/4-18 NPT female5c. 7/16-20 UNF female (per MS33656E4)

Electrical termination

6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)

6b. MS type connector to mate with MS3106-14S-6S (max. 160 °F)1

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C) 1

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (8m [26 ft]) (max. 80°C)1

6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable

Shunt calibration 8a. Precision internal resistor 6

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down) 10% increments

@ 20 °C

Wetted diaphragm

17-4 PH stainless steel

Bridge type 11a. Square bridge6

11b. Symmetrical bridge6

11c. Square & symmetrical bridge6

Zero and span adjustment

14b. Top access to pots7

14a. No access to pots

Increased line pressure

25b. 3000 psi line pressure25c. 5000 psi line pressure

Interfaces 53e. Signature calibration6

53t. TEDS IEEE 1451.4 module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 59: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell • Sensing and Control 3

High Line Wet/Wet Differential Pressure Transducer

INTERNAL AMPLIFIERS

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA

0 V to 10 V or ±10 V @ 5 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 V or 26 Vdc to 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db

Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse voltage protection Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector(std)2

A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl (+) OutputW Case ground

R (+) SupplyBl (+) OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00.

TyPICAL SySTEM DIAgRAM

1/4-18

MOUNTINg DIMENSIONS AND CHARACTERISTICS

2X

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 60: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008716-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model HL-A-5 High Line Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-

vides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.)

3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.

4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent; consult

factory.11. Internal amp and termination dependent; consult factory.

Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An avail-able alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to amplifier housing.

* Not available with FM approval** On units > 200 psid the sum of full scale pressure must be <= 9500

psi, on units < 200 psid consult factory

WARNINgPERSONAL INJURy

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINgMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

RANgE CODES

Range Code

Availableranges

Range Code

Availableranges

BN ±50 psid CT ±750 psid

BP ±75 psid CV ±1000 psid

BR ±100 psid DJ ±1500 psid

CJ ±150 psid DL ±2000 psid

CL ±200 psid DN ±3000 psid

CP ±300 psid DR ±5000 psid

CR ±500 psid DT* ±7500 psid

Connector Unamplified

A, B (+) excitation

C, D (-) excitation

E (-) output

F (+) output

WIRINg CODES

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 61: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Ultra Precision Wet/Wet Differential Pressure Transducer

Model TJE

DESCRIPTIONModel TJE Ultra Wet/Wet Differential is a bonded foil strain gage

transducers designed to accept fluid in both ports and measure

differential pressure ranges from 50 psid to 750 psid. Standard

features such as overload stops and stainless steel construction

provide unit durability in rugged industrial environments. Each is

bi-directional and achieves accuracies of 0.1 % full scale.

A variety of standard options are available with the Model TJE

Ultra including the traditional removable pressure adaptors for

cleaning purposes, extended temperature ranges, alternative

pressure ports, internal amplifiers options, and electrical termi-

nations.

FEATURES• 0.1% accuracy

• 50 psid to 750 psid

• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc

to 10 Vdc output

• Intrinsically safe available (2N option only)10

• CE approved11

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 62: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

2 Honeywell • Sensing and Control

Model TJE

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid

Accuracy ±0.1 % full scale

Output (standard) 2 mV/V (nominal)

Line pressure 1500 psi

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature, effect, zero ±0.25 % full scale/100 °F

Temperature, effect, span ±0.25 % reading/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 10 Vdc

Excitation (acceptable) Up to 10 Vdc or ac

Insulation resistance 10000 mOhm @ 50 Vdc

Bridge resistance 350 ohm

Shunt calibration data Included

Elec. termination (std) PTIH-10-6P or equivalent (hermetic stain-less)

Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Media Gas, liquid

Overload-safe 1500 psi

Pressure port 1/8-27 NPT female (2)

Dead volume 0.25 cu. in

Wetted parts material 17-4 PH stainless steel

Case material Stainless steel

RANGE CODES

Range Code Available ranges

BN ±50 psid

BP ±75 psid

BR ±100 psid

CJ ±150 psid

CL ±200 psid

CP ±300 psid

CR ±500 psid

CT ±750 psid

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Pressure ranges (psid)

50, 75, 100, 150, 200, 300, 500, 750

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F

1g. 70 °F to 325 °F6

1h. 70 °F to 400 °F6

1i. -65 °F to 250 °F6

1j. 0 °C to 50 °C1m. -25 °C to 110 °C

Internal amplifiers

2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2t. 0 Vdc to 10 Vdc2j. 4 mA to 20 mA

(3 wire) output2k. 4 mA to 20 mA

(2 wire) output12

2n. (2N) 4 mA to 20 mA (2 wire) intrin-sically safe12

2u. Unamplified, mV/V output

Internal amp enhancements

3a. Input/output isolation8

3d. Remote buffered shunt calibration

Pressure ports5 5c. 7/16-20 UNF female5h. 1/8-27 NPT female (2)

Electrical termination

6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)

6b. MS type connector to mate with MS3106-14S-6S (max. 160 °F)1

6e. Integral cable: Teflon (-54 °C to 245 °C)

6f. Integral cable: PVC (-30 °C to 70 °C)

6g. Integral cable: Neoprene (-20 °C to 80 °C)

6h. Integral cable: Silicone (-54 °C to 150 °C)

6i. Integral underwater cable (8m [26 ft]) (max. 80°C)1

6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable

Shunt calibration 8a. Precision internal resistor7

Special calibration

9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down)

10% increments @ 20 °C

Wetted diaphragm

17-4 PH stainless steel10a. 316 stainless steel

Bridge type 11a. Square bridge6

11b. Symmetrical bridge6

11c. Square & symmetrical bridge6

Zero & span adjustment

14a. No access 14b. Top access6

O ring seals 26a. Metal26b. Vi-Ton26c. Teflon

Interfaces 53e. Signature calibration6

53t. TEDS IEEE 1451.4 module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 63: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Honeywell • Sensing and Control 3

Ultra Precision Wet/Wet Differential Pressure Transducer

iNTERNAL AMPLIFIERS

Amplifier specifications

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA

0 V to 10 V or ±10 V @ 5 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 V or 26 Vdc to 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc

9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db

Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse voltage protection Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)2

A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl (+) OutputW Case ground

R (+) SupplyBl (+) OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00.

MOUNTING DIMENSIONS AND CHARACTERISTICSTyPICAL SySTEM DIAGRAM

NOTE: For long cable runs or electronically noisy environments, an amplified sensor or locally mounted amplifier is often preferred.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 64: Honeywell Test & Measurement - Differntial Pressure Sensors · Configurable Pressure Transducer Model FP2000 DESCRIPTION The FP2000 series is a configurable differential pressure

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008717-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model TJE Ultra Precision Wet/Wet Differential Pressure Transducer

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURy

• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.

• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal

provides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with inter-nal amplifier options 2b, 2c, 2t and 2j.)

3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.

4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent;

consult factory.11. Internal amp and termination dependent; consult factory.12. 5000 ohm bridge required

Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to housing.

Connector Unamplified

A, B (+) excitation

C, D (-) excitation

E (-) output

F (+) output

WIRING CODES