Holley GSM/GPRS Smart Gas Meter Solution
1. Overview
GSM/GPRS Series Smart Gas Meter is a new generation intelligent gas meter
developed by Holley, which evolved on prepaid gas meter. It adopts Siemens GSM
Module 900/1800/1900Mhz communication module to send consumption data timely
to the data center. This AMR technology will make operators benefit from recording
the load profile and Input-Output Ratio online.
2. Conform Standards
MID 2004/22/EC and EN12405;
IEC 60079-0, 11;
UNICN13757, IEC60870;
3. Main Feature
3.1 Working principle
MAIN
BOARD
POWER
SUPPLY
Embeded High Density Energy
lithium Cell
Working lifetime≥10 Year
MEASURING
DATA
ACQUISITION
TWO REED SENSOR ACQ
ELECTRIC SQUARE
COMMUNICATE
GSM?GPRS
ELECTRO
VALVE
REAL-TIME
CLOCK
Gas
Leakege
Monitor
LCD/ALARM
DEVIATION≤10PPM
(Monthly maximum datetime
allowed deviation≤1minute)
1. with pressure presetting,
2. USE Pt trasducer(platinum resistence) to measure Temperature ,
then correct the Correctedted the metrology data To STANDARD
condition
GAS METER WORKING DIGRAM
3.2 General Description
MCU: Using TI or MICROCHIP Company’s SCM, low power dissipation and
high performance.
Powered by built-in 12AH li-battery, service life >10 years
Using mature dual reed switches measuring technology.
Communication Module: GSM 900/1800/1900MHz
Electro-valve: high reliable, lower voltage loss, low power dissipation.
Clock Module: Using high accuracy clock chip from Dallas Company, clock
offset≤10PPM.
Temperature compensation: Adopting PT1000 sensor, conform to EN60571 A
Class
Communication Interface: Using standard RS232, protocol is definable.
Allowing interface of gas leaking alarm.
3. 3 Tariff Calculation
Following parameters can be recorded automatically:
User’s information in five different time intervals. Time point of calculating
could be preset.
Gas consumption records of recent one hundred days could be saved and easy
to get the gas consumption curve at any time interval.
3.4 Clock correction and Synchronization
Our gas meter has built in clock with perpetual calendar. The monthly
maximum time error is less than one minute. Clock can be synchronized by
handheld pc or the radio instruction from the administration centre.
3.5 Valve Control
Our gas meter has a built in electro-valve, to control the user’s gas consumption.
Under abnormal conditions like, battery running out, built in EEPROM damage,
measuring sensor damage, abnormal flow-rate, backing up meter parameter
error, gas meter will shut down valve automatically. After fixing errors, valve
can be re-opened by pressing the trigger button or switching off and switching
on the power supply.
3.6 Display
Our gas meter has both register display and LCD display. Without user’s
operation on meter, LCD screen will keep shut in order to preserve battery
power. When display button being pressed down, LCD screen will light on.
After releasing display button for sixty seconds, meter will enter low power
consumption mode, at the meantime LCD screen shuts down. The default
display content is accumulated gas consumption. By keep pressing the display
button, other information will display in turn. Displaying information is
accumulated gas consumption, recent month gas consumption, present time,
gas meter serial number.
3.7 Alarm Function
Under the condition like battery running out, electro-valve error, abnormal
clock error, the gas meter will alarm and display alarm information on the LCD
screen.
3.8 Measurement data upload
Our gas meter will upload user’s information to administration centre regularly.
The frequency of uploading is adjustable by the administrator.
3.9 Self-diagnostics and event in time report function
Our gas meter could carry out self-diagnostics aiming at the condition of meter
internal operating. And the information of self- diagnostics is as follows:
The accuracy of clock
Whether the remaining energy of battery is sufficient or not. Once the
inadequate remaining energy of battery is being detected, it will report to
administration centre for the in time battery replacement.
Whether operation of Valve is normal or not.
Whether the condition of memory is normal or not.
Whether the condition of measuring sensor is normal or not.
Whether the parameters of internal operation are normal or not.
3.10 Operation parameters recording
Our gas meter can record operation parameters automatically. And these parameters are
as follows:
The number of times of magnetic disturbance and the happened time of latest
magnetic disturbance.
The number of times of battery replacement and the happened time of latest
battery replacement.
The number of times of high flow rate and the happened time of latest high flow
rate.
The number of times of illegal open of meter cover and the happened time of
latest meter cover open.
Gas meter alarm and the happened time of latest gas leakage.
3.11 Temperature compensation
GSM Series smart gas meter ( G1.6-G4 ) have the characteristic of temperature
compensation. Built-in software will automatically transfer the value detected into
standard environment’s value(1.01325 bar,15°C )
Formula:Vb=(Pm/Pb) *(Tb/Tm)*(Zb/Zm)*Vm
Its accuracy to reach the European standards of measurement EN12405
Note: 1000 sample meters will do not have the above functions, but the data format
has reserved the words byte for this function.
After sample meter period, we will supply you with this function, and the same time,
Display way will use LCD only.
3.12 Authorized valve open through long distance
Management system can authorize users to open valve through wireless network. The
electro-valve will shut down automatically due to user’s illegal operation or gas meter
fault. After fault being ruled out, user can make an application of re-open valve to
administration centre, and administration centre can authorize user through long
distance. After accepting the authorization, then user can open the valve by pressing the
button on the gas meter.
3.13 Data transmission
To make sure the safety of data trasmissiting, this meter adopts international universal
DES encryption.
3.14 Maintenance & Management
It is easy to manage the smart gas meter. This meter can exchange data with data center
bidirectional, and also can exchange data with HHU locally. Operator can download the
Key, can configure the setting, and the same time can read data through HHU device.
3.15 Online configuring tariff function
This smart gas meter has the characteristic of online configuring tariff. Operator will
benefit from this function.
3.16 Software updating
Interface is reserved to update software. We will supply you with device to update
software. So, it will be very convenient for operator to updating software.
4 GSM DTU main features
4.1 Product Specifications
4.1.1 Voltage Specification: 3.6V (Input), high capacity lithium battery
4.1.2 Data capacity specification: Gas meter data stored in local memory, and memory
can be extended.
4.1.3 Module specification: Siemens’s industrial communication module adopted, 4
frequency bands supported.
4.2 Functions
4.2.1 Support working in SMS mode or GPRS mode
4.2.2 Support setting of intervals for collecting and uploading data
4.2.3 Support checking of local GSM signal strength
4.2.4 Support remote reading of gas meter ID
4.2.5 Support local and remote time calibration
4.2.6 Support local storage of collected data, which memory can be extended as per
customer requirement
4.2.7 Support real-time battery indication. The low battery threshold can be configurable
to alert the users to change the battery.
4.2.8 Support setting of system working hours for extending battery life
4.3 Hardware working principle
Battery Input
Power Supply
management
Output: 4.2V 3.3V
MCU
LED
Indication
Gas meter data
acquisition interface
SIM
card
slot
LED
Indication
Hardware
Clock
Voltage
Testing
Clock Battery
RS232 interface
Siemens module
system
Data
storage
NULL
Jumper
testing input
Base Gas meter
HT6000 GSM DTU
4.4 Main functions
4.4.1 Low consumption: The DTU can be waked up passively by the gas meter or
actively by the system on schedule. In working mode, the DTU can passively accept the
gas meter push data or actively pull to read the gas meter data
4.4.2 High capacity data storage: According to the protocol, the data stored can be read
through RS232 interface and the memory can be extended according to the data volume.
4.4.3 Working mode setting: The DTU can work in SMS mode or GPRS+SMS mode.
4.4.4 SMS center setting: Maximum 15 bytes. Please consult the local mobile operator
to get the parameter.
4.4.5 Group SMS: Users can specify more than one data centers to upload the data to
multiple data center servers.
4.4.6 Interval of data acquisition: 10-50000 min as per customer requirement. The
battery life can be extended if the interval is set to be longer.
4.4.7 Interval of data uploading: 10-50000 min. 10-50000 min as per customer
requirement. The battery life can be extended if the interval is set to be longer.
4.4.8 DTU online time: 30-1800 sec. The energy consumption of the module can be
controlled in order to extend the battery life.
4.4.9 SMS data processing mode: It supports transparent mode and local storage mode;
if the data cannot be uploaded due to network failure, the data can be stored in local
memory to ensure that the data will not be lost.
4.4.10 DTU ID: 12 byte for DTU ID; the local gas meter address can be inquired.
4.4.11 GSM status: Users can inquire the GSM signal strength to avoid low
communication success rate caused by the poor quality of local network.
4.4.12 Battery level inquiry: Users can set a threshold to trigger the low battery
alarming and inquire the voltage of the battery. In low battery mode, reminders will be
sent to the users for battery replacement.
4.5 Battery features and Sleeping Strategy
4.5.1 Battery Type
We use high capacity and power battery which is safe and stable with low
self-consumption
4.5.2 Energy-saving Strategy
The system works in three working modes: Sleeping mode, data-receiving mode and
data-uploading mode.
Workflow:
After the system is powered, the DTU enters the data-receiving ready mode. If no data is
received, it enters the sleeping mode.
When the DTU is in sleeping mode, the system can be waked in two ways:
1: The system can be waked by the gas meter module to enter the data-receiving mode. It
returns to sleeping mode after the data receiving is completed. The waking time interval
is set according to the data-acquisition interval of the gas meter.
2: The system enters data-uploading mode. After the data uploading is completed, it
enters the sleeping mode again.
4.5.3 Battery Consumption Analysis
We use 12AH high power lithium battery which is very popular and easy to be sourced in
the market.
Working parameter and mode:
Interval of data acquisition: 180 min, uploading interval: 4320 min (3days),DTU online
time: 300 sec.
Based on the above parameters, the system can work for 9 years.
5 Specifications of Uplink and Downlink SMS
All SMS data length should be less than 140 bytes.
All parameters can be configured through serial port or SMS:
The serial port is mainly used for local configuration while SMS is mainly used for remote
configuration.
The SMS setting is illustrated as below:
The tree structure in the left includes all the node names and the corresponding phone
numbers.
If the SMS mode is selected, the messages should be sent according to the format as
below:
Header of SMS uplink frame + SMS content
The SMS uplink frame starts like this: SMSsend13116742086F, among which SMSsend is
the beginning, followed by 3-15 byte target phone number and ended up with F, and plus
the content to be send.
For example, to set the working mode of the data center, assume the password is
“123456” and working mode “1”.
Then format of SMS message is:
SMSsend13116742086F*SET123456WKMD=1&
Responding frame of server DTU for downlink data
The frame header returned: SMSback13116742086F
For example: SMSsend13116742086F*SET123456WKMD=1&
Responding data:
Sent successful: SMSback13116742086Fsetok
Sent failed: SMSback13116742086Fsetfaulure
GSM closed: SMSbackGSMclosed
5.1 The DTU Formats of Downlink
SMS message format mainly includes 4 types: reading format,
setting format, special format and sending format.
5.1.1 SMS format outline
SMS format setting:
*+read-write operation+password of 6 digit +one or >one query items+&,the query
items are separated with ‘#’.
Starting symbols: ‘*’
Read-write operation: GET&SET
6 digit password: admin password is HTGPRS,initial password is 为 000000.
One or >one query items: the parameters are separated with ‘#’.
Ending symbol:‘&’
After read-write success, a SMS will be returned.
5.1.2 SMS setting
A SMS will be returned after successful setting
For example:
① To set the IP address of data center, imagine the password is “123456”,IP address is
192.168.1.1,then the SMS format is :
*SET123456DCIP=192168001001&
② To set the serial interface number of data center, imagine the password is‘123456’,
serial interface number is‘2008’,then the SMS format is:
*SET123456DCPT=02008&
③ To set multiple data formats, imagine the password is “123456”,IP address is
192.168.1.1, the communication port number of data center is 2000,the APN is CMNET,
heart beat cycle is 8, then the format is:
*SET123456DCIP=192168001001#DCPT=02000#GAPN=CMNET#HBCY=5&
5.1.3 SMS Read
①To read the IP address and the communication port number of data center, imagine the
password is‘123456’, the read format and returned SMS format are :
Read: *GET123456DCIP&
Responding: *GETDCIP=192168001001#
②To read multiple parameters, imagine the password is‘123456’,the read format and
returned SMS format are :
Read:*GET123456DCIP#DCPT#GAPN#HBCY&
Responding :
*GETDCIP=192168001001&DCPT=02000&GAPN=CMNET&HBCY=005#
5.1.4 Special command
Re-link GPRS network command.
*SET123456RLIK&
Re-linked GPRS network command returned
*SETOK#>>12345678RELIKING
5.1.5 Sending message
The data sent is the data set in the textbox, either HEX or asc.
SMSsend13116742086F123456789
6. DTU Software Management Workflow
The PC software collects all the uploaded data and performs data analysis and exporting
functions.
7. DTU Functions (optional)
The GPRS function is optional to send the data to the target server. The cost will be
comparatively lower especially for transmission of large data volume (SMS service is
charged per message while GPRS is charged according to the data volume).
The GPRS function is more complex and the battery consumption will be higher (More
steps to access GPRS). The advantage is that large volume data can be sent (SMS can
contain max 140 bytes while a GPRS packet length can be 1500 bytes at maximum)
8. Note
DTU(full name: Data Transmission unit)
DTU terminal ID:
Set by user, the ID of the module
SMS:
Text message
Working mode:
SMS mode &GPRS(TCP,UDP)mode; In SMS mode, only SMS function supported.
9. Network topography
CDMA/GSM/GPRS
BILL &MANAGEMENT SYSTEM
WEB SERVICE
client
client
client
firewall
router
internet
表具终端
operator
operatoroperator
Before deploying smart gas meter, Operator should set up customer profile in the
management system, and then write user information into SIM Card. Once this SIM card
is inserted into smart gas meter, smart gas meter complete its register process.
10 Electronic part specifications
Conform
standards EN1359 and OIML R31
Accuracy Class Class 1.5 Tariff and TOD
3 Tariffs,
5TOD
intervals
Backup Battery 3.6VDC, Cap.
12AH RTC accuracy 0.5s/d(23℃)
Battery’s Life
NOT LESS
THAN 10
YEARS
Static working
current(without
GSM)
10µA
Operational
temperature -20 ~50 ℃
Average
Rel.Humidity ≤93%
Explosion-Proof
class BПB
Basic measuring
unit 0.01 m3
11 Base meter specification
Item Unit Model
G1.6 G2.5 G4
Nominal flow-rate (Qn) m 3/h 1.6 2.5 4
Maximum flow-rate
(Qmax) m 3/h 2.5 4 6
Minimum flow-rate
(Qmin) m 3/h 0.016 0.025 0.040
Total pressure absorption Pa ≤200
Operation pressure range kPa 0.5~30
kPa 0.5~50 kPa
Cyclic volume dm3 1.2
Permiss
ible
error
Qmin≤Q<0.1Q
max % ± 3
0.1Qmax≤Q≤Q
max % ±1.5
Min. recording reading dm3 0.2
Max. recording reading m 3 9999.999 99999.999
Operational ambient
temperature ℃ -20~+50
Storage temperature ℃ -20~+60
Central distance mm 110
Connection thread M30x2, 3/4”, 1"1/4 (or by
customized)
Dimension mm 225x195x170(H×W×D)
Weight kg 2.00
Outside casing Quality steel sheet, thickness is
0.8mm
Service life years 15
Surface painting Polyester powder plastics coating (gray)
Index cover Printed index cover of polycarbonate or index
cover of aluminum bezel with glass.
12. Electro-valve specification
Actuating medium Natural gas、Coal gas、Liquefied petroleum
gas
Current capacity scope 0~6m³/h
Working pressure scope 0~4.2KPa
Relative humidity ≤90%
Pressure loss ≤50Pa
Sealing property (outside) No leakage under 20KPa
Sealing property (inside) 10KPa (3min)≤120pa
Durability Normal working>10000
Working current ≤80mA(3V)
Working voltage DC3~6V
Peak current 220 mA (3V)
Opens and close cycle 2S±0.1S (3V)
Structure The material uses Metaformaldehyde Rubber