153
HMIs Human Machine Interfaces Human Machine Interfaces HMIs HMIs

HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

Embed Size (px)

Citation preview

Page 1: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Human Machine InterfacesHuman Machine Interfaces

HMIsHMIs

Page 2: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Human Machine Interfaces

MP+MP+ TerminalsTerminals FutureFuture

TCP / IPTCP / IP

Page 3: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E710E710

E700E700

E900E900E910E910

E300E300

E200E200

E100E100

E600E600

E900VTE900VT

The E-series of HMIs

E50E50

Page 4: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E50 - low cost

Background lit text display 2x164 function keysRS422 with RS232 in the same Dsub +5 VDC, external or from PLCText blocks

Page 5: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E100 - small but strongBackground lit text LCD-display2 rows x 20 characters4 function keysText blocksTime channelsReal-time clockRecipe handlingRS-232C and RS-422 ports+5 VDC, external or from PLC64 Kbytes flash memoryTransparent modeHMI Tools support

Page 6: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E200 - As simple as it can beBackground lit text LCD-display4 rows x 20 characters, 5 mm text height5 function keys5 LEDs (two colour)Text blocksTime channelsReal-time clockRecipe handlingRS-232C and RS-422 ports64 Kbytes flash memoryTransparent modeHMI Tools support

Page 7: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E300 - Low-end graphicBackground lit graphic LCD-displayTwo colours, 240 x 128 pixels8 function keys16 LEDs (two colour)Graphic and text blocksTime channelsReal time trendsRecipe handlingRS-232C and RS-422 ports1 expansion slot128 Kbytes Flash memory, expandable to 8MbTransparent modeHMI Tools and TCP/IP support

Page 8: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E600 - one step upBackground lit graphic LCD-displayTwo colours, 240 x 128 pixels16 function keys16 LEDs (two colour)Graphic and text blocksFunctionality as E300Historical trendsRS-232C and RS-422 ports1 expansion slot256 Kbytes Flash memory, expandable to 8MbTransparent modeHMI Tools and TCP/IP support

Page 9: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E700 - A trend composerBackground lit graphic LCD-display256 colours, 320 x 240 pixels16 function keys14 LEDs (two colour)Graphic and text blocksFunctionality as E600RS-232C and RS-422 ports2 expansion slots400 Kbytes Flash memory, expandable to 8MbTransparent mode HMI Tools support and TCP/IP support

Page 10: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E710 - with new hardwareBackground lit graphic touch LCD-display256 colours, 320 x 240 pixels8 function keys8 LEDs (two color)Graphic and text blocksFunctionality as E700RS-232C and RS-422 ports2 expansion slots400 Kbytes Flash memory, expandable to 8MbTransparent modeHMI Tools support and TCP/IP support

Page 11: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E900 - Even bigger

Background lit graphic colour display256 colours TFT, 640 x 480 pixels22 function keys20 LEDs (two colour)RS-232C and RS-422 ports2 expansion slots1.6 Mbytes Flash memory, expandable to 8Mb220 VAC power supplyTransparent modeHMI Tools and TCP/IP support

Page 12: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E910 - touch it!Background lit graphic touch display256 colours TFT, 10,4”, 640 x 480 pixelsRS-232C and RS-422 ports2 expansion slots1.6 Mbytes Flash memory, expandable to 8MbDimensions 290 x 250 x 105 mm 220 VAC power supplyFunctionality as E900

24VDC version now available!

Page 13: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E900VT - more inputs...Background lit graphic TFT-display256 colours, 10,4”, 640 x 480 pixel 22 + 28 function keys ( IFC-64E )20 two color + 28 green LEDsRS-232C and RS-422 ports1 expansion slot1.6 Mbytes Flash memory, expandable to 8Mb220 VAC power supplyFunctionality as the E900

Page 14: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E610 - preliminary

Touchversion of E600B/W LCD displayCompactLow priceRelease Q4 2000

Page 15: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Expansion cardsMemory expansion with IFC-MCIncrease project memory with up to 8Mb Back-up of recipes and projectsTransfer of files to other terminals

Profibus DP IFC-PBDPSlave connection to Profibus DP

TCP/IP network IFC-ETTP, IFC-ETCXTerminal network and Internetenable via Ethernet

Page 16: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Expansion cardsExternal function keys with IFC-128EFor connection of up to 128 extra function-keys

Parallel printer with IFC-PIFor connection of an parallel printer

A-bus interface IFC-GA (E900/E910 only)Direct connection to the A-bus

Page 17: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

IFC-PI - Parallel printer port

Print outs of graphic and text blocks, reports and alarm lists– Graphics requires a HP PCL5, HP PCL6 or Epson FX80 compatible

printer

– If IFC PI is used a printer can not be connected to the RS-232 port

E300 and E600 have no support for HP PCL5/6 printers Black and white print outs only

Page 18: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

IFC-PI - Parallel printer portConnectable to

– E300 version 4.0 or higher (only with Epson FX-80) – E600 version 4.02 or higher (only with Epson FX-80)– E700 version 4.0 or higher– E710 version 4.0 or higher– E900 version 1.01 or higher– E910 version 4.02 or higher

Page 19: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

IFC-GA - Direct bus connectionWith the expansion card, IFC-GA, and the bus-interface A7GT-BUS installed, you can connect the E900 and E910 terminals directly to the base unit on an A(nS)-system.The communication between the PLC and the terminal will be very effective with the IFC-GA, because the terminal communicates directly with the A-bus on the PLC.

The standard RS-232/422 ports will be free for other equipment.

Page 20: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Before: Today:

Omron.dll

Omron.hlpOmron.pdf

Terminal code+

Drivers

Project

Terminal code

Driver

Project

The new concept

Page 21: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

WEBWEB

The new conceptDownloadable driversDownloadable driversAll terminals in the E series from version 4.0The driver and the system program areseparated in the terminalNew drivers can be used without a update of MP+Installation via Internet using MP+ or from floppy (first download from web) Current driver is automatically transferred to the terminal by MP+New standard cables to new PLC systemsManual in pdf-format to each driver

Page 22: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

2 ports gives you freedomTransparent modeCommunication with the PLC system via the terminalMitsubishiOmronMatsushita

No protocol mode- Communication with external units i.e. barcode readers

Serial printer

Page 23: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

GPP/WINGPP/WIN MM+ MM+

Transparent mode

Reach PLC through terminal in operationOnline changesEasier troubleshooting

Page 24: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Individual customised products - from simple panels to PC platforms Integration into your machine designCustomised OEM products, your operator control concept in style and functionality

What can we offer you:

• Individual design and front layout

• Modular Hardware

• Flexible Software

• We will implement your requirements

- So You can be successfully in business

• Professionalism and competence is our name

And You:

Be an individual...

Are you an individual?

Page 25: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

The lifecycle - Of a terminal...Even at the design stage we try to think in a long time perspective The choose of :

– Components– Material Recycled Recycling– Handling– Transports Minimum

And in the end...We take care of old used products, and sees that every part is handled in a minimum non-polluting way.As our contribution to the environment .

Page 26: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

The usual information way

RUN STOP

FWD REV

OperatorProcess/MachineProcess/Machine

Do it the hard way...

Page 27: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

HMIHMI

Or the easy way!HMI as information provider!

The HMI-solution gives you:Information in a easy wayThe Information will be clear and in right timeEasier to determine when changes occur

Process/MachineProcess/MachineOperator

Page 28: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

You will save:Money

Effective

Flexible

Simplicity

Time

Easy - Handle

Quick - Learn

Simple - Install

Right information - In Right Time

Page 29: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

6

Basic functionsAlarm handlingRecipe handlingRealtime clockTime channelsTrend diagramPassword handling

Page 30: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E 710

Operator interfaceTextGraphicColorsTouch screenLEDsFunctionkeysPrintouts

Page 31: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Mac Programmer+Easy to useWindows 95, 98, 2000 and NTDocumentationBack-upFull support for Windowscopy/pasteToolbox and ToolTipsMultiple project can be open at the same timeCompatible name list with MELSEC MEDOC and MELSEC MEDOC +Support for MXChange

Page 32: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Structure

Using a tree structure when developing a project

Page 33: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Block manager

Simplifying the handling of the blocks.Gives the engineer a visual overview how the project is created.

Page 34: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Object basedAll object data is stored in the terminalThe signals is configured directly in the objectNo PLC-programming is needed*Only the object´s which is viewed on the screen is updated

* except Profibus

Page 35: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Downloadable drivers

Now you are just a click from upgrading your drivers

Page 36: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

The Internal Name list

For easy changing of different PLC devices

Page 37: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Message library

Manoeuvrable message objects– 64 libraries can be manoeuvrable with 512 texts,

40 characters– Values between 0-65535 can be linked with texts

Page 38: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

News in Mac Programmer+

32-bit version to Windows 95, 98, 2000 and NT Supporting downloadable driversSupporting TCP/IP networkInstallation from CD

Page 39: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

News in Mac Programmer+

New configuration of peripheral unitsAcknowledge of individual alarms from the PLC systemAlarm on the negative edge

Page 40: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

More news!Modem handling in all terminals except E50

– Call up with the terminal– 10 different numbers stored in the terminal– 1 number stored in the PLC system

Larger size on the alarm text in E900System monitor in E700, E710, E900 and E910

Page 41: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

More news!

Show terminal in text blocksPrinting text strips to all terminals from MP+Improved project documentation in print-outsUse terminal font in MP+Cursor colour in the alarm list can be changed

Page 42: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

And more….Recipes sorted in alphabetic orderTurning off printing from the PLC system to avoid conflicts when transparent mode is usedMin- and max limits on numeric objects in graphic blocksThe alarm group name can contain national charactersNew data formats

– HEX 16-bit, 32-bit– BCD 16-bit, 32-bit– Float without exponent

Page 43: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

The Installation CDMAC Programmer+ 32-bitHMI Tools 32-bit All current driversManuals to all products

– E-series and MAC-series– Expansion cards– Installation manuals– Drivers

Floppy-copying of Full version, Demo and Transfer

Page 44: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

New manualsNew E-series manual

– The same manual to all E-terminals and MP+

New installation manual– The same manual to all E-terminals– Enclosed with all terminals

Separate manual to each driver– Downloaded with the driver in MP+

All pdf-manuals are available at WEB-site and on installation CD

Page 45: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

HMI ToolsWindows 95, 98, 2000 and NT Transferring of recipes, trends and alarm listsDownloading of system programsCommunication via modem

MP+ Transfer is a separate program

Page 46: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIsWhy choose an operator terminal from Mitsubishi?High QualityUser friendlyFunctionalityOne Software for all terminalsPossibility to upgrade the operating systemHigh quality supportAnd of course the openness

Page 47: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

http://www.mitsubishi.co.uk/automationhttp://www.mitsubishi.co.uk/automationhttp://www.e-terminals.comhttp://www.e-terminals.com

Support at the webDownloadable:Latest versions of software's Demo ProjectsProduct newsDriversManualsManufacturer´s declarationsUpcoming featuresApplication examplesFAQ

Page 48: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

The Open Concept

The Open Concept

Drivers & Connections

Page 49: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

DriversMelsec A (C24*, CPU, E71** or Profibus DP**)Melsec A-bus (A-bus*)Melsec A CC-Link connection (AJ65BT-G4)Melsec FX (CPU or 485ADP*)Melsec QnA (QC24*, QCPU* or Profibus DP**)Freqrol FR-A/EMelservo MRJ2CS100

* Can not be used with E50** Can not be used with E50, E100 or E200

Page 50: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Drivers

SIMATIC S5 (3964R/RK512*, PG-port* or Profibus DP**)SIMATIC S7 (3964R/RK512*, MPI*, PPI or Profibus DP**)

* Can not be used with E50** Can not be used with E50, E100 or E200

Page 51: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

DriversABB

– SattCon (Comli master*)

Allen-Bradley– Micrologix (DF1)– SLC500 (DF1 or DH485**)

Control Techniques– Unidrive (ANSI*)

Delta Tau– PMAC, UMAC (ASCII*)

Demonstration driver– Internal in the HMI

DVT Vision System– SmartImage Sensor (ASCII or TCP/IP**)

Festo/Beck– IPC, FEC series (FXT CI*)

GE Fanuc– Series 90 (SNPX)

Hitachi– H Series (HCOM*)

IAI– SuperSEL (Serial*)

* Can not be used with E50** Can not be used with E50, E100 or E200

Page 52: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

DriversIdec

– FA-1/2/Junior/Micro1 (FA-series 1:1 expanded*)

– FA-3 (FA series 1:1*)

– MICRO3/3C (Micro Computer Link)

Klockner Moeller– PS4 series (SUCOM-A*)

Koyo– Direct logic series (DirectNET* or K-sequence)

Matsushita– FP-series (MEWTOCOL-COM)

Modicon– All PLC types (Modbus master ASCII/RTU or

Modbus slave RTU*)MXCC

– VLC (Serial* or Profibus DP**)

Omron– All PLC types (Hostlink)

* Can not be used with E50** Can not be used with E50, E100 or E200

Page 53: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

DrivesSAIA

– PCD series (SBUS*)

SEW Eurodrive– Movidrive (Movilink*)– Movidyn (Movidyn*)– Movitrac (Movitrac*)

Telemecanique– TSK series (UniTelway*)

Toshiba– PROSEC T-series (Computer Link)

VT100Yaskawa

– MP9xx series (MemoBus master RTU*)

* Can not be used with E50** Can not be used with E50, E100 or E200

… … and more will come!and more will come!

Page 54: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

How to make a connection

Page 55: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

TCP/IPor

UDP/IP

BDTP

PLC-programE71-profile

IFC-ETCX

Server

Client

Client

Mitsubishi - E71 driver

The PLC-systems in Melsec A/QnA(S)-series via AJ71E71 or AJ71QE71 using the ASCII protocol.All E-series terminals can be used, with the exception of E100 and E200.Requires Ethernet card.

Page 56: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Mitsubishi - MELSERVOAll E-series terminals can be usedMR-J2-C-S100RS422 or RS232 connectionMultidrop of up to 32 servos possibleRead/Write all inverter parameters, digital/analog signals, alarm codesAll E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

Page 57: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Point-to-point

MultidropRS-485

RS-422

RS-232

Default station number

Mitsubishi - MELSERVO

Cable as drawing in the manual

Page 58: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

FREQROL FR-A/FR-EAll E-series terminals can be usedFR-A and FR-E seriesRS422 or RS232 connectionMultidrop of up to 32 inverters possibleRead/Write all inverter parameters, digital/analog signals, alarm codesAll E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

Page 59: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

FREQROL FR-A/FR-E

Cable as drawing in the manual

Point-to-point

MultidropDefault station number

RS-422

PU-Port

FR-A5NR

CAB-9

PU-Port

SC-FRPC

RS-422

RS-232 RJ45

Page 60: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

MXCC <-> E-series alt.1

PROFIBUS-DP connectionE300-900 can be connectedMXCC-program handles the HMI-profile

Page 61: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

RS232

I/O-bus

MXCC <-> E-series alt. 2 Serial connectionMXCC-program (Profile) All E-series HMIs can be usedLow price connectionSurvives NT-crashTerminal network through Ethernet possible

Page 62: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Cable as drawing in the manual

ABB - COMLI Master

Supports multidrop

RS-422RS-485

Nod ID:

CAB-8

CA

B8

Page 63: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Allen-Bradley DF1 Micrologix

The PLC-systems in the Micrologix 1000-series

CAB-2

RS-232

This node = TerminalRemote node = PLC

CRC-16 checksumFull duplex

8-polMini-Din

Page 64: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Allen-Bradley DF1 SLC-500

The PLC-systems SLC 500, SLC 5/01, SLC 5/02, SLC 5/03 and SLC 5/04Requires the module 1747-KE, 700 DEM(The DF1 connection at SLC 5/03 and SLC 5/04 is not recommended because of more disturbance)

CAB-5

RS-232

This node = TerminalRemote node = PLC

CRC-16 checksumFull duplex

Cable 1747-C13from Allen-Bradley

DH-485

Page 65: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Control Technique - UNIDRIVE

All E-series terminals can be usedInverters in the Unidrive series with serial interface i. e. UD 71.RS422 or RS232 connectionMultidrop of up to 32 servos possibleRead/Write all controllers parameters, digital/analog signals, alarm codesAll E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

Page 66: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Point-to-point

Multidrop

Default station number

RS-422

RS-422

RS-485CAB-8C

AB

8

RS-422

2-wire

4-wire

RS-422

Control Technique - UNIDRIVE

Cable as drawing in the manual

Page 67: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Delta Tau - PMAC/UMAC

All E-series terminals can be usedRS422 or RS232 connectionPoint to Point or Multidrop Read/Write all controllers parameters, digital/analog signals, alarm codesAll E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

Page 68: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

MAC 40+-CAB

RS-422

Default station number

Multidrop is performed by a band cable between the PMAC/UMAC systems

Delta Tau - PMAC/UMAC

The Positioning-system in Delta Tau PMAC/UMAC-series

Page 69: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Demonstration driver

Driver for demonstration without PLC-system99 M-coils99 data registers4 counters4 timers

Page 70: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

GE Fanuc SNPX

The terminals supports all GE Fanuc PLC systems, connected via the SNPX protocol.

RS-422

CAB-4

SNP ID numberNo PLC-programrequires for thecommunication

Page 71: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

RS-422

Idec8-pol

connector

RJ11

RS-422

Contain electronically devices, se driver manual

Idec - FA series

The PLC-systems in Idec FA-series

Cable as drawing in the manual

Page 72: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

RS-422

RS-232

8-polMini-din

8-polMini-din

Default station number

RS-485CAB-8

CA

B8I

Alt.I

Idec - Micro 3-series

The PLC-systems in Idec Micro 3-series

Cable as drawing in the manual

Page 73: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

RS-422

RS-232

RS-232

15-pol

15-pol

RJ12

Default station number

Koyo - DirecNet & K-Sequence

Koyo Direct Logic Series K-Sequence PLC Koyo via the DirectNET

Cable as drawing in the manual

Page 74: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

RS-422

RS-232

RS-232

15-pol

9-pol

5-polMini-Din

Default station number

Matsushita - FP seriesThe PLC-systems in Matsushita FP-series via the MEWTOCOL-COM protocol

Cable as drawing in the manual

Page 75: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Modbus ASCII / RTU

Supports Multidrop

RS-422RS-485

CAB-8

CA

B8

Default station number

Cable as drawing in the manual

Page 76: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Omron Hostlink

The terminals supports all Omron PLC systems, connected via the Hostlink protocol.Supports transparent mode

CAB-3

RS-232

No PLC-programrequires for thecommunication

Default station number

Page 77: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Siemens SIMATIC S5 PG1/AS511

The PLC-systems SIMATIC S5 90, 115, 135 and 155

No PLC-programrequires for thecommunication

CAB-7

CAB-1

Siemens Converter 6ES5 734-1BD20

RS-232

RS-422

Page 78: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Siemens SIMATIC S5 3964R/RK512

The PLC-systems SIMATIC S5 90, 115, 135 and 155Requires communication card CP525Writing is only possible to DB, other devices can only be read

CAB-6

CAB-5 RS-232

RS-422

Null modem

The terminalHigher priority=Master

PLC3964R / RK512=Slave

Page 79: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Siemens SIMATIC S5 Profibus DP

The PLC-systems SIMATIC S5 90, 115, 135 and 155Requires Profibus DP interface (IFC-PBDP)

IFC-PBDP

PLC programHMI-profile

Requires timedelay in connection with

fast CPU:s

Page 80: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Siemens SIMATIC S7 MPI

The PLC-systems SIMATIC S7 300- and 400-series

CAB-6

CAB-5

RS-232

The MPI station number of the terminal

The MPI stationnumber of the PLC system

Highest MPI address

RS-422

+CAB-11

Page 81: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Siemens SIMATIC S7 PPI

The PLC-systems SIMATIC S7 200-series

Cable as drawing in the manual

CAB-8

RS-422

The station number of the terminalThe stationnumber of the PLC-system

Highest PPI address

Only the terminal can be Master in

the network PPI-Port

Page 82: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Siemens SIMATIC S7 3964R/RK512

The PLC-systems SIMATIC S7 300- and 400-seriesRequires communication card CP341Writing is only possible to DB, other devices can only be read

CAB-5

RS-232

The terminalHigher priority

MasterPLC

3964R/RK512Slave

Page 83: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Siemens SIMATIC S7 Profibus DP

The PLC-systems SIMATIC S7 300- and 400-series Requires Profibus DP interface (IFC-PBDP)

IFC-PBDP

PLC-programHMI-profile

Page 84: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Toshiba

The PLC-systems in PROSEC T-series via Multidrop connection

Cable as drawing in the manual

MAC30/40-CAB

RS-422

RS-422

CR-01

The Computer Link protocol

RS-485 RS-232RS-485RS-485

CR

-01

Default station number

Page 85: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

CablesCAB1

– cable to connect Siemens SIMATIC S5/PG1 via Siemens Converter to the RS-232-port on the terminals in the E-series. 0,5 m.

CAB2 – cable to connect Allen-Bradley's PLC system Micrologix to the RS-232-port on the terminals in the E-

series. 3 m.

CAB3 – cable to connect Omron PLC system via the Hostlink protocol to the RS-232-port on the terminals in the E-

series. 3 m.

Page 86: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

CablesCAB4

– cable to connect GE Fanuc PLC system via the SNPX protocol to the RS-422-port on the terminals in the E-series. 3 m.

CAB5 – cable to connect Siemens SIMATIC S7/MPI via Siemens HMI Adapter, Siemens

SIMATIC S7/3964R, Siemens SIMATIC S5/3964R and Allen-Bradley/DF1 PLC-systems to the RS-232-port on the terminals in the E-series and to connect a PC to the RS-232-port on the terminals in the E-series. (MAC PROG/9-CAB) 3 m.

Page 87: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

CablesCAB6

– cable to connect Siemens SIMATIC S7/MPI via Siemens HMI Adapter, Siemens SIMATIC S5/3964R and PC to the RS-422-port on the terminals in the E-series. 3 m.

CAB7 – cable to connect Siemens SIMATIC S5/PG1 straight to the RS-422-port on the

terminals in the E-series. 3 m.

Page 88: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Cables

CAB8– to connect the terminals in the E-series to PLC-systems via RS-485.

Adapter placed on the RS-422-port at the terminals.

CAB9 – cable to connect Mitsubishi Fr-A / E inverters straight to the RS-422-

port on the terminals in the E-series. 3 m.

Page 89: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs2 serial ports gives you freedomTransparent mode

– Communication with the PLCsystem via the terminal, online

No protocol mode– Communication with external units

Serial Printer– Communication with a serial printer

Page 90: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Messagepacket

The Communication”Point to point”, master/slave

– Terminal read/write information.– PLC replys on requested information.

Signals which effects the communication time– Overhead signals except signals in the current block.– alarms, trends, display-signals,

LED-registers, block-prints, index, register for PLC-watch etc.

Page 91: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

The CommunicationSignals which NOT effects the communication time

– Signals connected to function

– keys, time channels, objects in alarm texts.

Effective communication = (as few message packets as possible)– Group signals.

– Don’t dump the watch with to short interval.

– Block change with display register.

– Packaging of signals (consecutive order).

Messagepacket

Page 92: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIsThe future requires new conceptsNew concepts reach new markets -new markets gives us new customersOpenness is one key to the futureMore effective development work Even higher quality

Page 93: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Internet technology

More openness

PC-based HMI functionality

Windows CE

More efficient tools

Internet technology

More openness

PC-based HMI functionality

Windows CE

More efficient tools

High functionalityEasy handlingOptimized for Mitsubishi Electric products

High functionalityEasy handlingOptimized for Mitsubishi Electric products

The HMI strategy

Page 94: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

* Supervisory connectivity- Remote HMI/PLC process monitoring/control- Diagnostics- Statistic reporting- Internet connection- Data file exchange

* Plant floor connectivity- All major PLC:s- PC-based control systems- Fieldbuses- Local networks

* Flexible HMI application- Data exchange with Word, VB, Excel.- Reuse of objects- More options for advanced users

* OPEN STANDARDS !- TCP/IP-Ethernet.- Windows CE/NT/95- OPC, ActiveX, COM/DCOM- Internet technology

Future customer requirements

Page 95: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Product hierarchy

CEZARCEZAR

SCADA system

Operator terminals

- Graphic

- Text

Page 96: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

CEZAR concept

MicrosoftMicrosoft®®

Windows NTWindows NT®®

MicrosoftMicrosoft®®

Windows CEWindows CE®®

C-terminalsAdaptions for NT / NT-E / CE

environment

Same concept-different platforms

DesktopAdaptions for NT

environment

Page 97: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

CEZAR concept

The CEZAR-RT and the CEZAR software will check if all the necessary components exist on the target platform. If not, they will be distributed automatically by the software.

CEZARDeveloping tool

*The Terminal Client Application must be purchased separate

CEZAR-RT( TCA )( TCA )

C-Terminal Any PC

The Terminal Client Application isalways included in the C-terminals

CEZAR-RT( TCA* )

Page 98: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

6

Basic functionsAlarm handlingRecipe handlingReal-time clockTime channelsTrend diagramsPassword handling

Page 99: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

E 710

125º

Operator interfaceTextGraphic/PicturesColoursTouch screenPrint-outsPossibility to start otherWindows applications

Page 100: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

3. Enterprise3. Enterprise2. Professional2. Professional1. Basic1. Basic

CEZAR developing toolThree selectable user levels:

Event driven programming (level 2-3)Programming withVisual Basic-script (level 3)Drag n’ DropActiveX controls Copy/Paste fromWindows

Page 101: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Improved HMI functionality (1)Data exchange with... Script language using… Extended character support- Unicode- True Type FontsMultimedia support- Video- Sound

Page 102: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Improved HMI functionality (2)Internet access

– Web Server - Allow access from other sites– Web Client - Get data from other sites

Network possibilities– Distributed objects– Shared data files (alarm list, application)– Network with NT-stations

Page 103: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Open systemMicrosoft technology:

– OPC - allows for 3.rd party drivers– COM/ActiveX - object component base– DCOM - distributed objects

Objects based:– Object accessible from external applications– Reuse of objects– Customer can create new objects

Page 104: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

CEZAR Connections

USB-PortsUSB-Ports2 x USB

Ethernet-PortEthernet-PortTP with RJ45

Parallell-PortParallell-Port

Serial-PortsSerial-Ports1 x RS4222 x RS232

Support for Multiple drivers

How many inputs do You have?

Page 105: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

MicrosoftMicrosoft®®

Windows NTWindows NT®®

Hardware specification NT (1)Intel/Pentium MMX 266 processor12.1” Touch TFT display, 800*600, 256 K coloursC&T 69000, 2MB SDRAM video Chips64 MB RAM memory, expandable to 128 MB6.1 GB hard drive , 2.5", EIDE2 x USB ports2 x RS-232 portsRS-422

Page 106: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Hardware specification NT (2)

Parallel portEthernet TP 100M, RJ-45 connector

32 bit PCI slot, 2 brackets2 x 16 bit PC104 slot, stackedKeyboard, Mouse and sound* connectors

MicrosoftMicrosoft®®

Windows NTWindows NT®®

* Optional

Page 107: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Future developments

Page 108: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Development areasMore E-series drivers will still comeStrengthen low-end area of E-seriesEX classified environmentIntegration of Internet-technologyUse the benefits from Windows CE and NTAnd...

Page 109: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

The HMI WEB

Page 110: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

BDTP

Server Client Server/Client

Overview TCP/IP networkFunctionality

– Terminal network, replacing MAC network, 10Mbit/s– Transfer data between PLC-systems– Project transfer– More will come ...

Connection possibilities– Ethernet Twisted Pair or coaxial– Serial

New expansion cards– IFC ETTP, Twisted Pair – IFC ETCX, Coaxial

Page 111: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIsOverview TCP/IP network - twisted pairIFC ETTP in each terminalMaximum length between terminal and HUB is 100 mTwisted pair CAT5, shielded or not shieldedRJ45 connectorThe number of connections on the HUB settles the maximum number of terminals connected to each HUBNo HUB if only two terminals

Page 112: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

SegmentSegment

Overview TCP/IP network - coaxial cableIFC ETCX in each terminalMaximum length on each segment is 185 mMaximum 30 units on each segmentMaximum 5 segments can be connected via repeaters and maximum 3 segments can have unitsCoaxial cable RG58Termination 50

Page 113: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

BDTP improvements in version 5Server Alarms

– - Define the alarm in the server,this will be sent to all the clients automatically when the signal is activated.

RAS* functionality– Automatic restart of clients when server restart.

* Recovery Automatically System

Page 114: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIsAvailable now!Available now!TCP/IP - step 2

Intranet / Internet connectionRemote monitoring/Maneuvering

– Via web-sites– Free Browser

Data transfer– FTP transfer

E-mail– SMTP

Page 115: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Local connections

Intranet– Local factory network– Good response time– Local domains

Call-up Intranet– World-wide access– Good response time– Local domains

Page 116: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

W.W.W.

Global connection - www

Internet– Published on the WEB.– Uncertain response time.– Global domains.– Mainly for data of public interest.

Page 117: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

HTMLblablablabbl

HTMLblablablabbl

HTMLHTML

HTML<ssi>-------l-----

Standard Web Browser(Internet Explorer,Netscape Navigator)

W.W.W.

WEB Server

WEB server Each terminal has a homepage. HTML-pages can contain real-time and PLC/HMI-data HTML-pages are created on PC and downloaded to the terminal

Page 118: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

W.W.W.

WEB server - remoteMonitoring/Manoeuvring and Control

Page 119: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

W.W.W.

WEB server - remoteMonitoring/Manoeuvring and Control

Page 120: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

HTML codesUser HTML-pages withSSI-code

– <-!get_date.fn-!->– <-!get_time.fn-!->– <-!get_diag.fn-!->– <-!get_ipaddr.fn-!->– <-!get_domainname.fn-!->– <-!get_mode.fn-!->– <-!get_device.fn-!->

Function executed when server sees special codes

Standard Web Browser(Internet Explorer,Netscape Navigator)

W.W.W.

Page 121: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

HTML codes

User HTML-pages withCGI-Scripts

– <-!set_date.fn-!->

– <-!get_time.fn-!->

– <-!set_mode.fn-!->

– <-!set_device.fn-!->

Standard Web Browser(Internet Explorer,Netscape Navigator)

W.W.W.

Page 122: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

HTML codes

Page 123: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Standard Web Browser(Internet Explorer,Netscape Navigator)

W.W.W.

WEB server - remoteMonitoring/Manoeuvring and Control

JAVA AppletView current screen of terminalRemote control terminal by mouse clicks on PC

Page 124: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

W.W.W.

WEB server - remoteMonitoring/Manoeuvring and Control

Page 125: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Standard FTP client(Included in Internet Explorer,Netscape Navigator)

W.W.W.

FTP Server

FTP server - data transferProcess data transfer

– Recipes

– log / Trend data

– Alarm list

Application data transfer– HTML files

Page 126: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

GPP/WIN (2001)MM+ (April 2001)

W.W.W.

Transparent modeReach PLC through networkRequires support from PLC configuration softwareTunneling PLC-protocols

Page 127: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Standard POP3 Mail server

SMTP Client

Outlook Express/Netscape.(POP3)Can redirect mails to f.ex GSM texts

W.W.W.

You have mail...

Mail on alarmReports through e-mail (textblock)Forwarding E-mails

Page 128: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

GOT Product line up

F900GOT

A900GOT

GOT Software

Page 129: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

F900GOT Range

F940GOT– F940GOT-LWD-E

Monochrome– F940GOT-SWD-E– 8 colours

F930GOT-BWD-E– Monochrome

Page 130: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

F900GOT functionsTouch screen with IP66F(F940GOT)Security function1:n Network Transparent ModeAlarm functionRecipe functionDevice MonitorGraphical and Text-Objects F940GOT replaces and contains all functions of FX-50DU-TK(S)-E

Page 131: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Communication connections

FX1, FX2, FX2C, FX0, FX0S, FX0N, FX2N,FX2NC

Q/A series

OMRON SYSMAC C seriesFUJI N series

PC board

PLC

CPU direct connection

CPU direct, PC link

CPU direct, RS232C

RS232C

Connection method

PC link

Allen-Bradley PLC SLC500 series

* Connection to Siemens PLC is also planned.

Page 132: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

146 mm 49 mm

75 m

mF930GOT-BWD-E Dimensions

Display size : 4.4-inch (280 x 80 dots)Display colour: 2-colour (blue/white)Display device: STNTouch switches: 4 x 15 = 60

(50 positions/screen can be set.)

Page 133: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

F930GOT benefitsSmall and Compact high performance GOT Dimensional analysis:

– Outer dimensions: 146 x 75mm– Depth: 49mm (45mm recessed into panel)

High resolution / Industry’s Premiere Resolution – The 240 x 80-dot screen (15 x 5 lines) provides the industry’s highest resolution in the small-class display category.

Long-Life Backlight / Industry’s Longest Lasting Backlight.– A full 50,000 hours of operation with a single Backlight.– This long-life Backlight offers maintenance-free operation.

Page 134: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

F930GOT benefitsQuick One-Touch Switching

– The FX2N and FX2NC series connected (direct CPU connection)– One-touch operations are conducted in 0.16sec with high-speed response.

Simple Multiple Connectivity (up to 4 GOTs maximum)– Using direct CPU connections with the MELSEC FX or A Series– A maximum of 4 F930GOTs can be connected to a sequencer.

Page 135: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

F930GOT-BWD-E IP66F Rating146 x 75 x 49mm- classed as the worlds smallest control unit.Easier on the eyes than any comparable screen on the market. Easy-to-read wide-angle LCD.Network expansion a standard feature for up to four units.Sampling mode for measurements and recording.

Page 136: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Networking Hardware

Terminal Network with up to 4 stations possibleTransparent mode

Main control panel

remote‚P remote‚Q remote‚R remote‚S

30m 15m 30m 15m

RS422RS232C RS422 RS232C

PLC

Page 137: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

45°

60°

50° 50°

F940GOT Display properties

Display properties– 320 x 240 Pixel– STN LCD – 8 colours or Monochrome– Excellent view from all angles

Page 138: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

•5.7in Terminal with less Dimension

•Water and oil resistent

•IP66F!

Display5.7In

162

11523.5 23.5Frame

130

8522

.522

.5(F

ram

e)

57F940GOT Dimensions

Compact size

Page 139: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Comparison of terminals

CategoryCategory

Touch keys

Parameters

Lamps

Memory

Freq.

Varieties

Display mode

Trigger

Alarmmode

FX-50DU-TKSFX-50DU-TKS F940GOTF940GOT

Samplingmode

History

32

Number

50

I/O

30 50

2,000

Dust/Water/Oil

2,000

IP65 IP65F

50 50

128K 512K

50 256

Same

+Oil resist.

800 2,000

200 1,000

2 4

x 2.5

ComparisonComparison

x 1.6

x 1.7

Same

x 4

x 5.1

x 5

x 2

Page 140: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Mitsubishi’s new GOT’sA900GOT seriesA985GOT-TBA-EU

– 256 colours 800x600 Pixel TFT 12”

A975GOT-TBA-B-EU– 256 colours 640x480 Pixel TFT 10,4“

A970GOT-SBA-B-EU– 16 colours 640x480 Pixel STN 10,4“

A960GOT-EBA-EU– Monochrome 640x400 Pixel EL 8,9“

Page 141: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Introducing A900GOT High speed screen data transfers and OS transfers.

– also store screen data from a GOT in a memory card (PCMCIA) and then edit to a PC

List program edit function– minor modification can be made on site– compatible with MELSEC-A Series– command list offers to write, monitor, insert, delete and parameter edit functions

Page 142: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Improved recipe handler

Programmable controller

D101D102D103

D***

Data 1Data 2Data 3

Data mm=Max. m=Max.

8k words8k words

n =Max. n =Max. 256256

Recipe data n

Recipe data 2

Recipe data 1

Commercial SRAM card or flash PC card

Page 143: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Recipes

Mem.card

Bus connection and RecipesFast Bus Connections

– use a MELSEC-A/QnA programmable controller for the fastest bus connection. – You can achieve similar performance from three GOTs connected by bus as from a

single connected GOT– high speed response via a bus connection for cyclic communication

Recipe functions– data can be stored onto memory cards useable by other GOTs

Page 144: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Password input

A900GOT Security

Security functions– 16 security levels

Page 145: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIsA900GOT Communication speed

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

FX CC-LINKtransient

CC-LINKcyclic

MNETtransient

MNETcyclic

UC24 Bus

Bus connection is fastest

Page 146: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

A900GOT dimensions

46mm

Size (W x H x D):

297 x 208 x 46 for colour Terminals268 x 192 x 49 for EL Terminal

Extremely slim and compactSlim line terminal using new Bus or RS422 communication modules

Page 147: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

ConnectionsA9GT-BUSS

– Bus connection

A9GT-RS4– Serial connection

PCMCIA card (withQnA series)– Memory cards for programs and recipe

Page 148: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

PLC connection

FX1, FX2, FX2C, FX0, FX0S, FX0N, FX2N, FX2NC

Q/A series

OMRON SYSMAC C seriesYasukawa series

PLC

CPU direct communication

CPU direct, PC link, A-Bus and Networks.

RS232C

Connection method

PC link

Allen-Bradley PLC SLC500 series

Page 149: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

GOT Software

GT Works, one Software for all GOT (AGOT and FGOT) (SWnD5C-GOTRE-E)FX-DU-SW-WIN-E (Ver.2.30) only for FGOT

F900GOT

FX-DU-WIN-SW-E SW4D5C-GOTRE-SW

Common

DU GOT

Page 150: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

GT Works

Converter for old projectsDocumentation functionImproved help functionDebug functionProject managerTemplates and tool barExpanded librariesSimulation Tools

Page 151: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

GOT Software

Compatibility A900GOT and A870GOT

Compatibility FX-50DU-TKS and F940GOT

GOT800 GOT800 screen datascreen data Convertor

GOT900 GOT900 screen screen datadata

FX-50DU-TKSFX-50DU-TKSFX-50DU-TKSFX-50DU-TKS F940GOTF940GOTF940GOTF940GOTFX-DU-WIN-SW

Page 152: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Questions?

Human Machine InterfacesHuman Machine Interfaces

Page 153: HMIs Human Machine Interfaces HMIs. HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

HMIs

Human Machine InterfacesHuman Machine Interfaces

HMIsHMIs