124 3567810 911121316 1415171819202122
NA+1.04
H S
EL
EC
15
90
K
g h
=1
,9
3 m
AIR
E 3
0 T
r
AIR
E P
RE
SIC
IO
N N
o 4
AIR
E 3
0 T
r
AIR
E P
RE
SIC
IO
N N
o 3
15
90
K
g h
=1
,9
3 m
15
90
K
g h
=1
,9
3 m
AIR
E P
RE
SIC
IO
N N
o 1
AIR
E 3
0 T
r
AIR
E 3
0 T
r
AIR
E P
RE
SIC
IO
N N
o 2
15
90
K
g h
=1
,9
3 m
1,92 m
900 kg
PDU 125 KVA
PDU 120 KVA
1,92 m
900 kg
BA
NC
O D
E
BA
TE
RIA
S
20
00
kg
BA
NC
O D
E
BA
TE
RIA
S
20
00
kg
h=
1
,8
7 m
h=
1,87 m
UP
S 2B
120 K
VA
530 kg
BA
NC
O D
E
BA
TE
RIA
S
20
00
kg
20
00
kg
BA
NC
O D
E
h=
1
,8
7 m
BA
TE
RIA
S
AIRE PRESICION
AIRE 8 Tr
900 Kg h=1,93 m
AIR
E 8
T
r
AIR
E P
RE
SIC
IO
N
90
0 K
g h
=1
,9
3 m
BANCO DEBANCO DE
BATERIAS
BATERIAS
2000 kg
h= 1,87 m
UPS 1A
530 kg
120 KVA
h= 1,87 m
2000 kg
BATERIAS
h= 1,87 m
BANCO DE
BATERIAS
BANCO DE
h= 1,87 m
2000 kg 2000 kg
h= 1,87 m
AIR
E 8
T
r
90
0 K
g h
=1
,9
3 m
AIR
E P
RE
SIC
IO
N
900 kg h=
2m
400 kg h= 2m
CUARTO DE UPS A
CU
AR
TO
D
E U
PS
B
850 kg h= 2m
TA
BLE
RO
S D
IS
TR
IB
UC
IO
N
UPS 15 KVA
RA
MA
B
CUARTO DE TABLERO
SERVICIOS AUXILIARES
900 kg h=
2m
RA
MA
A
TA
BLE
RO
S D
IS
TR
IB
UC
IO
N
CARRIERS B
CARRIERS A
PDU 1A
PDU 1B
PDU 120 KVA
1,92 m
900 kg
PDU 2A
900 kg
PDU 125 KVA
PDU 2B
900 kg
1,92 m
AIRE PRESICION
AIRE 8 Tr
900 Kg h=1,93 m
h=
1,87 m
UP
S 1B
120 K
VA
530 kg
UPS 1A
530 kg
120 KVA
h= 1,87 m
400 kg h= 2m
D.A.H.
D.A
.H
.
D.A.H.
F.A.S.
F.A.S.
F.A.S.
F F
F
F FF
F FF
F
F
FF
F
F
F
F
F
F
R
R
R
R
MM
MM
MM
MM
MD SM
P.C
.I.
F.A
.S
.
F
F
3
MMMD
SM
3
MR
FFF
FF
F
MRMR
MR
MR
MR
MR
2
R
R
A
A
A
Viene de Sotano.
Baja a piso Falso
Sube a
ambiente
Principal
PR
MM
MD SM
3
PR
MM
MD SM
3
PR
MM
MD SM
3
PR
MM
MD SM
3
PR
PR
MR
Integracion
Control Acceso.
L01D001 L01D002
L01D003
L01D012
L01D011
L01D010
L01D004
L01D005
L01D006
L01D015
L01D014
L01D013
L01D007 L01D008
L01D009
L01D017
L01D016
L01D018
L01D019
L01D020
L01D021
L01D024
L01D023
L01D022
L01D027
L01D026
L01D025
L01M001
L01M002
L01M003
L01M004
L01M005
L01M006
L01M009
L01M014
L01M015
L01M013
L01M012
L01M011
L01M010
L01M089
L01M090
L01M088
L01M087
L01M007
L01M008
L01M020
L01M021L01M019
L01M016
L01M017
L01M018
L01M029
L01M027
L01M026
L01M025
L01M022
L01M023
L01M024
L01M028
L01M030
L01M071
L01M076
L01M074
L01M072
L01M073
L01M075
L01M031
L01M032
L01M070
L01M036
L01M034
L01M033
L01M035
L01M041
L01M042
L01M040
L01M037
L01M038
L01M039
L01M044
L01M043
L01M046L01M045
L01M057
L01M058
L01M053
L01M054
L01M055
L01M056
L01M052L01M051
L01M050
L01M047
L01M048
L01M049
L01M059
L01M060
L01M061
L01M063
L01M062
L01M069
L01M068
L01M067
L01M064
L01M065
L01M066
PLANTA BAJA
ESCALA 1:75
G E
A
S
C
E
N
S
O
R
U
N
C
E
N
T
R
A
L
D
E
G
A
S
E
S
U
N
C
E
N
T
R
A
L
D
E
G
A
S
E
S
S
G
C
A
S
C
E
N
S
O
R
S
G
C
_
S
O
T
A
N
O
P
A
R
Q
U
E
A
D
E
R
O
M
O
T
O
S
1
2
C
U
P
O
S
C
O
M
P
R
E
S
O
R
U
N
A
L
PARQUEADERO
PIEZOCONO
MAQUINA
EXTRACCIÓN AIRE
DEPÓSITO COMBUSTIBLE
FOSO SALIDA DE AIRE
FOSO SALIDA DE AIRE
SALIDA DE AIRE
TRATAMIENTO ACÚSTICO
FOSO SALIDA DE AIRE
SALIDA DE AIRE
TRATAMIENTO ACÚSTICO
ENTRADA DE AIRE
TRATAMIENTO ACÚSTICO
ENTRADA DE AIRE
TRATAMIENTO ACÚSTICO
SALIDA DE AIRE
TRATAMIENTO ACÚSTICO
M/C
TS EP
IN
TE
S EP
M/C
T
IN
TE
SE P
M/C
T
IN
TE
SE P
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
1
0
1
1
1
2
0
5
0
6
0
7
0
8
0
9
1
0
1
1
1
2
2
4
2
5
2
6
2
7
2
8
2
9
3
1
3
2
3
3
3
4
3
5
4142434445
54555657
6
4
5
9
6
1
6
5
6
7
464748
6
8
6
9
6
0
6
6
3
0
40 39
53
T
A
N
Q
U
E
6
0
0
G
A
L
G
E
N
1
T
A
N
Q
U
E
6
0
0
G
A
L
G
E
N
2
SOTANO
ESCALA 1:100
F
L01D028
A
L0
1M
07
8
L0
1M
07
7
T
E
X
P
.
M
M
L
0
1
M
0
8
1
T
E
X
P
.
M
M
L
0
1
M
0
8
2
A
L
0
1
M
0
8
0
L
0
1
M
0
7
9
A
L
0
1
M
0
8
3
L
0
1
M
0
8
4
T
E
X
P
.
M
M
L
0
1
M
0
8
6
T
E
X
P
.
M
M
L
0
1
M
0
8
5
Panel Control Incendios.
F
A
T EXP.
P.C.I.
D.A.H.
MR
MC
MM
MD
SM
F.A.S.
R
Detector Aspiracion Humo.
Fuente Auxiliar Voltaje.
Detector Humo Fotoelectrico.
Detector Termico Explosion Proof.
Estacion Manual Descarga
Modulo de Relevo
Modulo Monitor.
Modulo de Descarga
Modulo de Control.
Switch de Mantenimiento.
Switch Principal - Reserva
Estacion Manual Alarma.
Boton de Aborto.
Sirena con Luz Estroboscopica.
Campana.
Cantidad por Modulo
Caja de Paso.
# Mx
PR
Flujo de Lazo cableado deteccion.
Tuberia EMT Ø
3
4
''.
CONVENIO INTERADMINISTRATIVO
No. 12 DE 2015 ENTRE LA
UNIVERSIDAD NACIONAL DE
COLOMBIA Y EL SERVICIO
GEOLÓGICO COLOMBIANO
CENTRO DE EXCELENCIA
EN GEOCIENCIAS
DR. IGNACIO MANTILLA PRADA
RECTOR UNIVERSIDAD NACIONAL
JAIME FRANKY RODRIGUEZ
VICERRECTOR SEDE BOGOTÁ
JAIME AGUIRRE CEBALLOS
DECANO FACULTAD CIENCIAS
GUSTAVO ADOLFO SARMIENTO
DIRECTOR DPTO GEOCIENCIAS
DISEÑO
LEONARDO ÁLVAREZ YEPES
M.P. Nº 2570047064 CND
ARQUITECTO DISEÑADOR
EDWIN ALEXANDER ALFONSO
ARQ. COORDINADOR TÉCNICO
LUZ AIDA RODRIGUEZ
ARQ. COORDINADOR GENERAL
CONTIENE
VERSIONES
ARCHIVO DIGITAL
PLANO
DETECCION INCENDIOS.dwg
ESCALA
FECHA
CONVENCIONES
PLANCHA Nº
DR. OSCAR PAREDES ZAPATA
DIRECTOR SGC
IVÁN SARMIENTO GÁLVIS
SECRETARIO GENERAL SGC
ALBERTO OCHOA
DIRECTOR GEOCIENCIAS BÁSICAS
GLORIA PRIETO
DIRECTOR RECURSOS MINERALES
MARTA CALVACHE
DIRECTOR GEOAMENAZAS
FERNANDO MOSOS
DIRECTOR ASUNTOS NUCLEARES
HÉCTOR ENCISO
DIRECTOR LABORATORIOS
MARGARITA BRAVO
DIRECTOR GESTIÓN DE LA
INFORMACIÓN
ANTONIO STORINO
ASESOR CONVENIO SGC
LEONARDO ÁLVAREZ YEPES
DIRECTOR CONVENIO
DISEÑO DATACENTER
ING. ANDRES ROSAS
M.P. CN20635728
ING. MARIO MARTINEZ
M.P. CN205 36998
A24
24
DE INCENDIOS
DETECCION PUNTUAL
AGOSTO DE 2017
LAS INDICADAS