Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
G1.0Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
COVER SHEET
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
The CE GroupPaul Seward, PEMark D'Rosario, Principal400 Remington St. Suite AFort Collins, CO 80524
970.266.9888970.266.8876
OWNER
PROJECT TEAM
The Harmony Foundation, IncDot Dorman, Executive Director1600 Fish Hatchery RdEstes Park, CO 80517
MECHANICAL ENGINEERCIVIL/STRUCTURAL ENGINEER
Cornerstone Engineering & Surveying, IncKerry Prochaska, PEMike Todd, PE1692 Big Thompson Ave. Suite 201Estes Park, CO 80517
970.586.2458970.586.2459
BASIS Architecture, P.C.Steve Lane, AIA1692 Big Thompson Ave. Suite 100Estes Park, CO 80517
970.586.9140970.586.9149
ELECTRICAL ENGINEER ARCHITECT
RJ McNutt & AssociatesTravis Pofahl, PERon Boone, Designer1140 38th AvenueGreeley, CO 80634
970.330.3266970.330.3667
SHEET INDEX
G1.0 Cover SheetG1.1 Code Notes
Note: Civil Engineering in separate package
A2.0 Floor PlanA2.1 Roof PlanA3.0 ElevationsA3.1 ElevationsA4.0 SectionsA4.1 SectionsA4.2 SectionsA4.3 SectionsA5.0 Door Schedule & DetailsA5.1 Window Schedule & DetailsA6.0 Reflected Ceiling PlanA6.1 Reflected Fire Rated Ceiling PlanA7.0 Interior ElevationsA7.1 Interior ElevationsA7.2 Finish Plan & ScheduleA8.0 DetailsA8.1 Details
S1.0 Structural NotesS2.0 Foundation PlanS2.1 Roof Framing PlanS2.2 Clerestory Framing & East Wall Shear
M0 HVAC – IndexM0.1 HVAC – SchedulesM0.2 HVAC – SchedulesM100 HVAC – Level One PlanM200 HVAC – Attic PlanM300 HVAC – Roof PlanM400 HVAC – DetailsM401 HVAC – SectionsM402 HVAC – Control SequencesM500 HVAC – Isometric
P0 Plumbing – IndexP0.1 Plumbing – SchedulesP100 Plumbing – Under Floor PlanP101 Plumbing – PlanP400 Plumbing – Enlarged PlanP500 Plumbing – Isometric
E1.0 Electrical Cover SheetE2.0 Electrical Site PlanE3.0 Lighting PlanE4.0 Power PlanE5.0 Electrical One-LineE6.0 Electrical Panel ScheduleE7.0 Electrical SchedulesE80 Electrical Details
Harmony Foundation IncAdmissions / Detox Building
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
G1.1Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
CODE NOTES
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
11'-0
"+/-
20'
-0"
+/-
36'
-0"
ASSUMED PROPERTYLINE BETWEEN BUILDINGS(future Dining Hall to South)
GATE w/ 'PANIC'BAR & ALARM
GATE w/ 'PANIC'BAR & ALARM
FULL HEIGHT 1HRSMOKE BARRIER
MAX TRAVEL DISTANCETO EXIT = 97'
MAX TRAVEL DISTANCETO EXIT = 67'
1 HR WALLS NON-BEARING(RATED B/C INTERRUPT RATED CLG)
1 HR WALLS NON-BEARING(RATED B/C INTERRUPT RATED CLG)
1-HR BEARINGWALLS1 HR WALLS NON-BEARING
(RATED B/C INTERRUPT RATED CLG)
1HR WALL (RATED FMINSIDE ONLY) DUE TO LOCATION
ON PROPERTY
TYPICAL EXTERIOR WALL1HR (RATED FM INSIDE ONLY)DUE TO TYPE V-A BUILDING
EAST WALL OF HALL TO BECONSTRUCTED AS NON-RATEDSMOKE PARTITION - ALL PENETRATIONSSEALED w/ APPROVED MATERIALSTO PREVENT PASSAGE OF SMOKE
I-2DETOXIFICATION
FACILITY
BBUSINESS AREA
EXIT
EXIT
EXIT
EMERGENCYEXIT
EXIT
EMERGENCYEXIT
EXIT
EXITACCESS
EXITACCESS
EXITACCESS
EXITACCESS
EXITACCESS
EXITACCESS
EXITACCESS
EXITACCESS
13/32" = 1'-0"
Code Plan
Harmony Foundation, IncAdmissions-Detox Building
2009 IBC Code Study
Use & Occupancy Class -- Chapter 3 Proposed: B Business (Office areas) I-2 Detoxification facility (20 beds)
Special Occupancy Requirements -- Chapter 4Group I-2
Corridors shall be continuous to exits and constructed as smoke partitions.Waiting areas, constructed as required for corridors, permitted to be open to corridors
Smoke barriers required to divide story into min 2 smoke compartments 30sf per patient required on each side of smoke barrier
407.5 Full NFPA Sprinkler req’d with quick response sprinklers per 903.3.2 405.6 Fire alarm system required
Height & Area Limitations -- Chapter 5Type V-A buildingUse Group: B
Allowable area: 18,000 sf (3 stories)
Use Group: I-2Allowable area: 9,500 sf (1 story)Increase for separation: 4,500 sf [0.75-0.25]30/30 = 50%Increase for sprklr: Not Taken
Total Allowable I-2: 14,000sfTotal Proposed: 10,470sf
Non-Separated occupancies (Sec 508.3): Building conforms to height and area requirementsfor most restrictive occupancy (I-2) No separations required.
Types of Construction -- Chapter 6Type V-A: Any materials permitted by code
Fire-resistive rating: Table 601 - Type V-AStructural Frame: 1 hrBearing walls 1 hrFloor 1 hrRoof 1 hr
Exterior wall protection: Table 602I/B occupancy: West, North & East Walls 0hr < 30’South Wall 1hr 10 < X < 30’ (Per 705.5 exterior walls >10’ separation rated from inside only)
Fire - Resistive Construction -- Chapter 7 Opening Protectives
West, North & East walls: Unlimited unprotected openings > 30’South wall 15 < X < 20: 75% in Fully Sprinklered buildings20 < X < 25: No Limit in Fully Sprinklered buildings
Combustible Projections: Allowed (Type V), Unprotected (>20 separation)Fire Walls/Fire Barriers: NoneShaft enclosures: Clerestory - 1hr required per 708.4 (2hr provided)
Fire Partitions: NoneSmoke Barriers: 1hr Per 710.4 Ex: Smoke barriers terminate at rated ceilingsSmoke Partitions: I-2 corridors (No rating, but must meet requirements of 711 for smoke partitions)Horizontal assemblies: 1hr (Mech Floor)Opening Protectives: Corridor walls: positive latching req'd, 1/3hr provided Smoke barriers: 1/3hr Concealed Spaces:
Provide fireblocking in wood frame construction per Sec 717Draftstopping not req’d where Full NFPA 13 sprinkler system provided
Interior Finishes - Chapter 8 Flame Spread:
I-2: Exits/Corridors: Class B Rooms + spaces: Class B* *Administrative rooms & rooms </= 4 occupants: Class CB Exits Class B Rooms/Corridors Class C
Fire Protection Systems -- Chapter 9 Automatic Sprinkler systems - Full NFPA 13 system Fire Alarm:
Fire Alarm required Manual boxes not req’d if located at nurse’s stationAutomatic Smoke detection required
Means of Egress - Chapter 10 Main floor - B Business areas
North Offices: 750sf (gross) @ 1/100 = 8 occ’s Locker areas: 280sf (gross) @ 1/50 = 6 occ’s (1 exit req’d from this area) Meeting Room: 370sf (net) @ 1/15 = 25 occ’s (1 exit req’d) Reception/South Offices/Phone Center 2,130sf (gross) @ 1/100 = 22 occ’s (1 exit req’d)
Main floor - I-2 Detox areas Nurse’s Station/Exam rms:
1,405sf (gross) @ 1/100 = 15 occ’s
Locker/Bathrm: 445sf (gross) @ 1/50 = 9 occ’s Living Room: 450sf (net) @ 1/15 = 30 occ’s (1 exit req’d) Sleeping Area (max configuration) 1,350sf (gross) @ 1/120 = 12 occ’s (1 exit req’d) Max occ load from Mens/Womens: 51 occ’s
Locker/Bathrm: 445sf (gross) @ 1/50 = 9 occ’s Living Room: 450sf (net) @ 1/15 = 30 occ’s (1 exit req’d) Sleeping Area (min configuration) 855sf (gross) @ 1/120 = 8 occ’s (1 exit req’d) Min occ load from Mens/Womens: 47 occ’s
(Note typical occ load from Mens/Womens = 1,100sf/120 = 10occ’s) Max exit load from I-2 = 113 occ’s (min 2 exits req’d)
Provide means of egress illumination per 1006 Provide exit signs per 1011
Min egress width: 44-inches (Note: bed movement not required outside of sleeping areas)
Corridors: (Table 1018.1) (fully sprinklered)B > 30 occ - 0 hrI-2 >30 occ - 0 hr
Accessibility -- Chapter 11 Accessible route/entrances from accessible parking provided. Accessible toilet facilities provided Nurse's station not accessible - employee work area <300sf per 1104.3.1 Ex 1.
Plumbing Systems -- Chapter 29 B: 61occ's /2 = 31 each W/C - 1/25 - min 1 required ea sex, 2 add'l unisex baths provided I-2: 113occ's /2 = 57 each W/C - 1/25 - min 3 required ea sex, 4 provided
FIRE SPRINKLER SYSTEM:PROVIDE FULL NFPA13 SYSTEM THROUGHOUT BUILDING
WITH QUICK RESPONSE HEADS AS REQUIRED IN I-2 OCCUPANCY.DRY SYSTEM TO PROTECT COMBUSTIBLE CONSTRUCTION INATTIC. CONCEALED HEADS. NO PLASTIC PIPING PERMITTED.
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A2.0Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
FLOOR PLAN
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
N
E
3'-6
"7'
-0"
117
7'-0
"3'
-0"
D
5'-0
"7'
-0"
A3'-6"5'-0"
F3'-6"2'-6"
A
3'-6
"5'
-0"
A
3'-6
"5'
-0"
A
3'-6
"5'
-0"
A
3'-6
"5'
-0"
100
7'-0"8'-6"
B5'-0"5'-0"
C5'-0"7'-6"
B5'-0"5'-0"
134
7'-0
"6'
-4"
B5'-0"5'-0"135
7'-0
"6'
-4"
121
7'-0"3'-6"
133
7'-0"3'-6"
ZZ
5'-0
"5'
-0"
126
7'-0
"3'
-0"
B5'-0"5'-0"
A
3'-6
"5'
-0"
A
3'-6
"5'
-0"
E
3'-6
"7'
-0"
F
3'-6
"2'
-6"
118
7'-0
"3'
-0"
114
7'-0"3'-0"
115
7'-0"3'-0"
110
7'-0
"3'
-0"
109
7'-0
"3'
-0"
107
7'-0
"3'
-0"
108
7'-0
"3'
-0"
101
7'-0"6'-0"
102
7'-0"3'-0"
I
2'-0
"5'
-0"
XX5'-0"5'-0"
XX5'-0"5'-0"
VV
3'-9
"5'
-0"
145
7'-0"6'-
0"
H5'-0"6'-0"
155
7'-0"6'-0"
VV
3'-9
"5'
-0"
156
7'-0"6'-0"
G
5'-0
"12
'-0"
142
7'-0
"3'
-6"
YY5'-0"2'-8"
143
7'-0"3'-0"
WW5'-0"
3'-0"
164
7'-0"3'-6"
137
7'-0"3'-6"
G
5'-0
"12
'-0"
104
7'-0"3'-0"
157
7'-0
"3'
-0"
WW 5'-0"3'-
0"
144
7'-0
"3'
-0"
UU
5'-0
"2'
-0"
UU
5'-0
"2'
-0"
UU
5'-0
"2'
-0"
UU
5'-0
"2'
-0"
154
7'-0
"3'
-0"
153
7'-0
"3'
-0"
141
7'-0
"3'
-0"
140
7'-0
"3'
-0"
YY5'-0"2'-8"
158
7'-0"3'-0"
159
7'-0
"3'
-6"
XX
5'-0
"5'
-0"
160
7'-0
"3'
-0"
161
7'-0
"3'
-0"
XX
5'-0
"5'
-0"
124
7'-0
"3'
-0"
125
7'-0
"3'
-0"
J3'-6"4'-0"
K3'-6"2'-0"
J3'-6"4'-0"
K3'-6"2'-0"
151
7'-0
"3'
-0"
UU
5'-0
"2'
-0"
152
7'-0
"3'
-0"
UU
5'-0
"2'
-0"
149
7'-0
"3'
-0"
150
7'-0
"3'
-0"
UU
5'-0
"2'
-0"
UU
5'-0
"2'
-0"
UU5'
-0"
2'-0
"UU
5'-0
"2'
-0"
147
7'-0
"3'
-0"
148
7'-0
"3'
-0"
139
7'-0
"3'
-0"
138
7'-0
"3'
-0"
162
7'-0
"3'
-0"
163
7'-0
"3'
-0"
I
2'-0
"5'
-0"
I
2'-0
"5'
-0"
H5'-0"6'-0"
146
7'-0"6'-0"
I
2'-0
"5'
-0"
113
7'-0"3'-0"
119
7'-0"3'-0"
136
7'-0"3'-6"
122
7'-0"3'-0"
123
7'-0"3'-0"
127
7'-0"3'-0"
128
7'-0"3'-0"
131
7'-0
"3'
-0"
130
7'-0
"3'
-0"
129
7'-0
"3'
-0"
132
7'-0
"3'
-0"
122a
7'-0"3'-0"
123a
7'-0"3'-0"
144a
7'-0"3'-0"
157a
7'-0"3'-0"
103
7'-0
"6'
-0"
136a
7'-0"3'-0"
116
7'-0"3'-0"
YY
5'-0
"2'
-8"
112
7'-0
"3'
-0"
106
7'-0
"3'
-0"
111
7'-0
"3'
-0"
105
7'-0
"3'
-0"
C
C
B
B
A
A
D
D
D.6
D.6
E
E
I
I
I.1
I.1
J
J
H
H
F
F
E.3
E.3
7 7
8 8
9 9
5 5
3 3
2 2
1 1
6 6
4 4
4.1 4.1
5.9 5.9
B.6
B.6
G
G
F
F
3A3.0
3/A4.0 3/A4.0
3/A4.13/A4.1
3/A4.23/A4.2
26'-6" 20'-6" 17'-2" 12'-0" 8'-6" 3'-0" 10'-2 3/4" 15'-7 1/2" 13'-8 3/4" 9'-9" 2'-0" 12'-0"
9'-0
"16
'-3"
10'-7
1/2
"17
'-11
1/2"
17'-1
1 1/
2"10
'-7 1
/2"
16'-3
"9'
-0"
5 1/
2"10
'-4"
3 1/
2"4'
-0"3
1/2"
6'-3
1/4
"5
1/2"
9'-8
"3
1/2"
9'-8
3/4
"3 1/
2"8'
-2 1
/4"
3 1/
2" 7'-5
3/4
"3
1/2"
4'-2
"3
1/2"
10'-2
"5
1/2"
5 1/2"10'-9 1/2" 3 1/2" 10'-9 1/2" 3 1/2" 20'-5" 3 1/2"
2'-6 1/2"3 1/2"1'-9 1/2"
3 1/2"
3'-1 1/4"3 1/2" 9'-8 3/4" 3 1/2" 9'-8 3/4"
5 1/2"8'-0 1/2" 5 1/2" 7'-8 1/4"
3 1/2"5'-1 1/4"
3 1/2"
2'-8 1/2"
3 1/2"
6'-4 3/4"
3 1/2"5'-8" 3 1/2" 15'-5 1/2" 3 1/2" 7'-1 1/4" 5 1/2"
5 1/2"7'-5 1/2"
3 1/2" 29'-9 1/2" 5 1/2"2'-6 1/2"
4'-11"2'-2 3/4"
3 1/2" 2'-1 1/2"5'-1 1/4"
3 1/2"8'-2 3/4"
3 1/2"8'-2 3/4" 5 1/2"
5 1/2" 10'-9 1/2" 3 1/2" 10'-9 1/2" 3 1/2" 20'-0 1/2" 5 1/2"4'-9 3/4"
3 1/2"3'-1 1/4"
3 1/2"
5'-2 1/2"3 1/2"
2'-3"
5 1/2"6'-2"3 1/2"
5'-1"5 1/2"
8'-0 1/2" 5 1/2" 10'-1 1/2" 3 1/2" 10'-1 1/2" 3 1/2" 10'-1 1/2" 3 1/2" 10'-1 1/2" 3 1/2" 10'-2 1/2" 5 1/2"
9'-5
1/4
"5
1/2"
5'-1
1/4
"3
1/2"
7'-6
"3
1/2"
7'-6
"3 1/
2" 5'-1
1/4
"5
1/2"
9'-5
1/4
"
3 1/
2"2'-3
"3
1/2" 5'-3
"3 1/
2" 5'-3
1/4
"3
1/2"
11'-0
"3
1/2" 5'
-1 1
/4"
5 1/
2"
5 1/
2"7'
-8"
3 1/
2"7'
-8"
3 1/
2"4"
+/-
12"
MAT
CH P
ARTI
TIO
N C
L
5 1/2" 20'-0 1/2" 5 1/2"3'-4 1/2"
3'-3"3 1/2"
3'-8" 5'-8" 5 1/2" 11'-6 1/2" 5 1/2" 8'-0 1/2" 5 1/2" 11'-6" 3 1/2" 9'-11" 3 1/2" 9'-11" 3 1/2" 9'-11" 5 1/2"
2'-0"2'-5" 1'-9 3/4" 2'-11 1/4"
3'-1" 4'-7" 6'-4" 5'-4" 10'-9" 9'-9" 5'-6" 6'-3 1/4"2 3/4" 4'-0 1/4"
4'-3"2 3/4"
3'-0" 3'-0" 7'-2 3/4" 3'-8" 10'-0" 1'-11 1/2" 5'-8 3/4" 8'-0" 4'-7" 5'-2"
4'-0
"
5 1/
2"15
'-9 1
/2"
8'-4
"5
1/2"
6'-3
1/2
"5
1/2"
26'-1
"5
1/2"
6'-3
1/2
"5
1/2"
8'-4
"15
'-9 1
/2"
5 1/
2"
3 1/
2"7'
-1"
4'-1
"3 1/
2" 1'-1
"3 1/
2"3'
-11"3
1/2" 3'
-11"3 1/
2"
1'-1
3/4
"
3 1/
2" 4'-1
"3'
-6"
3 1/2
"4'-
2"3 1
/2"3 1/2"
2'-6 1/2"
3 1/2"5'-2" 3 1/2" 9'-9"
3 1/2"6'-8 1/2"
5 1/2"2'-6 1/2"
5 1/2"8'-0 1/2"
5 1/2"
2'-6" 5 1/2"4'-10 1/4"
3 1/2"8'-1 1/2"
3 1/2"8'-1 1/2"
3 1/2"1'-9 1/2"
3 1/2" 16'-5 1/2"3 1/2"
10'-1 1/2" 5 1/2"
5 1/
2"3'
-2" 3 1/
2"3'-2
"3
1/2"
9'-5
3/4
"3 1/
2" 5'-3
1/4
"3 1/
2"7'
-1"
3 1/
2"
5'-1
1/4
"3 1/
2"
4'-6"
5 1/
2"7'
-2"
3 1/
2"
12'-3
"4'
-0"
4'-0
"12
'-3"
3'-1
0"6'
-1 1
/2"
8'-0
"8'
-0"
6'-1
1/2
"3'
-10"
9'-0
"16
'-3"
10'-7
1/2
"17
'-11
1/2"
17'-1
1 1/
2"10
'-7 1
/2"
16'-3
"9'
-0"
11'-3
"5'
-0"
5'-7
1/2
"5'
-0"
6'-8
"6'
-7 1
/2"
4'-8
"4'
-8"
5'-3
1/2
"8'
-0"
4'-6
"6'
-1 1
/2"
3'-5
1/2
"7'
-7 1
/2"
5'-2
"
26'-6" 20'-6" 17'-2" 12'-0" 8'-6" 3'-0" 10'-2 3/4" 15'-7 1/2" 13'-8 3/4" 9'-9" 2'-0" 12'-0"
2'-6"2'-5" 1'-9 3/4" 2'-11 1/4"
3'-1" 4'-7" 6'-4" 5'-4" 10'-9" 9'-9" 4'-3" 4'-3" 3'-3" 6'-11 3/4"2'-2 1/4"
10'-1 1/2"3'-3 3/4"
6'-9 3/4" 6'-11"
4'-1"3 1/2"
6'-3"3 1/2" 2'-1 1/4"
3 1/2"
1'-0
" 1'-2
"
6"
2'-8" 3'-0" 3'-6"
3'-2
"6'
-5"
2/A4.3 2/A4.3
3/A4
.33/
A4.3
4/A4
.34/
A4.3
1
2
3
4 1A7.0
12A7.2
1
22A7.0
21 1A7.1
13A7.1
4A7.1
2A7.1
5A7.1
6A7.1
4
3
2
1 7A7.1
1
2
3
4 8A7.1
4W7A7.1
5
7A7.1
6 7A7.1
15A7.0
4A7.0
4A7.0
4A7.0
3A7.0
7A7.0
6A7.0
EMERGENCYEXIT ONLY
GATE w/ ALARMAT NURSE
STATION - PROVCONDUIT
45" UTILITYCABINET
ROOF HATCHABOVE
FOLDINGPARTITION WALLS
CONCRETEPATIO
GROMMET HOLE& CAP, TYP OF 4
HANDRAIL, BOTHSIDES OF STEPS,RE: DETAIL
CORNERGUARDSAT OUTSIDE
CORNERS IN HALL
CORNERGUARDS ATOUTSIDE CORNERS
IN WAITING
HANDRAILSIN HALL,RE: DETAIL
BLOCKING FOR FUTUREHANDRAIL BOTH SIDES,
HALL 137 & 160PARTITIONTRACK ABOVE
POCKET DOORPARTITIONCLOSURE
PARTITIONPANEL
STACKING
ACTIVE LEAFMUST PROVIDE32" MIN. CLEAREGRESS WIDTH(WHEN OPEN 90 ̊ )
STONE VENEERWALL,RE: DETAIL
FENCE,RE: DETAIL
ATTICACCESSPANEL
KNOX BOX
FDC
ELEC. GEAR,RE: ELEC.
FOAMED INSULATION INWALL CAVITIES ATBATHROOM EXTERIOR WALLS
FIRE EXTINGUISHERCABINET, TYP. OF (4)
ALTERNATE EXTERIORWALL ASSEMBLY,RE: DETAILS
3'-0"x7'-3"OPENINGS3'-0"x7'-3"OPENINGS
3'-0"x7'-3"OPENINGS3'-0"x7'-3"OPENINGS
SOAPDISP
PT DISP
8" LOG'COLUMNS'
LEAF FOR AUTO-OPERATOR
AUTO DOOR OPERATORBUTTON
WEST HALL WALL1HR SMOKE BARRIER
EAST WALLN.R. SMOKEPARTITION
SOAPDISP
AUTO DOOR OPERATORBUTTON
BOTH LEAVES OPENw/ AUTO OPERATOR
MANUAL FIREALARM PULL
STATION
P.T. DISP
SOAPDISP
MEN'SWAITING
BUSINESSCENTER
ADMISSION
ADMISSION
MEET + GREET
RECEPTION
MEETING ROOM
STAFFLOCKERS
PUBLICENTRY
RETAIL
WOMEN'SWAITING
HALL
HALL OFFICES
STAFFLOCKERS
WOMEN'S ENTRY
OFFICE
NURSE'SSTATION
SLEEPING AREA
LIVING
COURTYARD
BATHROOM
WOMEN'S CONF RM EXAM RM
STAFFBATH
MED
HALL
SLEEPING AREA
LIVING
COURTYARD
MEN'S
PRIVATEBATHROOM
EXAM RM
HALL
MECH/SPRINKLER
STAFF LOUNGE
AMBULANCE/STAFF/MEN'S ENTRY
IT
OFFICE
MED
MEDMED
STG
OFFICE
JAN
100
SEMI-PRIVATE
PRIVATE
SEMI-PRIVATE
SEMI-PRIVATE
SEMI-PRIVATE
PRIVATE
OFFICE
OFFICE
OFFICE
LOCKER/CHANGING
LOCKER/CHANGING
PRIVATEBATHROOM
VESTIBULE
101
102
103
122
117
116
118
119
123
126
120 121
104
105106
115
114
113
112
107
108109110111
HALL
BATH BATH
125 124127128
129VESTIBULE
133
134
162
138139
132
131
130
141
142
143
144
146
150
155
156
136157
158
135
137
140
159
161
160
CONF RM
BATHROOM
145
147
148
149
151
152
153
154
163
166VESTIBULE
165
RE: CIVILFOR WALKS
F
F
F
F
A3.13
2/A4
.02/
A4.0
1/A4
.21/
A4.2
2/A4
.22/
A4.2
1/A4
.01/
A4.0
2/A4
.12/
A4.1
1/A4
.11/
A4.1
1/A4
.31/
A4.3
164
11/8" = 1'-0"
Floor Plan
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A2.1Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
ROOF PLAN
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
L
3'-0
"3'
-0"
L
3'-0
"3'
-0"
L
3'-0
"3'
-0"
L
3'-0
"3'
-0"
L
3'-0
"3'
-0"
L
3'-0
"3'
-0"
L3'-0"3'-0"
L3'-0"3'-0"
4A2.1
3/A4.0 3/A4.0
3/A4.13/A4.1
3/A4.23/A4.2
2/A4.3 2/A4.3
3/A4
.33/
A4.3
4/A4
.34/
A4.3
2'-9 1/2" 29'-1 1/2" 2'-9 1/2"2'-9 1/2"
4'-8" 4'-8" 2'-9 1/2"
34'-8 1/2" 14'-11"
2'-9
1/2
"10
'-8 1
/2"
10'-8
1/2
"2'
-9 1
/2"
27'-0
"
1'-0" 1'-6"1'-6"3 1/2"
1'-6"
1'-6
"3
1/2"
1'-6
"
+/- 6"
2/A4
.02/
A4.0
1/A4
.21/
A4.2
2/A4
.22/
A4.2
1/A4
.01/
A4.0
2/A4
.12/
A4.1
1/A4
.11/
A4.1
1/A4
.31/
A4.3
3'X3' GRILLE
RTU, RE:MECH
TUBULAR SKYLIGHT,TYP. OF (2)
EXHAUST FANRE: MECH
ROOF ACCESSHATCH
ROOF EAVE
3'x3' WINDOWS INCLERESTORY
RIDGE VENT,RE: SPEC., TYPICAL
5" BOXGUTTER,TYPICAL
3"x4" DOWNSPOUT, TYP.TERMINATE AT CONC.SPLASH BLOCK U.O.N.
ROOF DRAINS,RE: PLUMBING
ROOF DRAINS,RE: PLUMBING
2 1/2 : 12
5 : 12
4 : 12
4 : 12
5 : 12
5 : 12
5 : 12
5 : 12
5 : 12
5 : 125 : 12
5 : 12 5 : 12
5 : 12 5 : 12
5 : 125 : 12
5 : 12 5 : 12
6 : 12
6 : 12
1 : 12
1 : 12
VENTILATIONSEPARATION WALLw/ 'BEAM' ABOVE,RE: DETAIL
ROOF DRAIN & OVERFLOWTO LAMB'S TONGUE
EPDM ROOFING @MECHANICAL WELL
DOWNSPOUT TOUNDERGROUND DRAIN,RE: CIVIL, TYP. OF (3)
STANDING SEAMMETAL ROOF,
TYPICAL
SNOW GUARDS,TYPICAL
SLOPE ROOFw/ TAPEREDINSUL. TYP.
OPEN TOBELOW
INSULATED ROOFHATCH, w/ INTEGRALCURB, RE: SPEC
ROOF HATCH MFR'sTELESCOPING SAFETY RAIL
METAL WALL PANELRE: ROOF PLAN
FLASHING + COUNTER-FLASHING
EPDM ROOFING
RATED ROOF-CEILING ASSEMBLY
FABRICATED STEELLADDER, RE: SPEC
TUBULAR SKYLIGHTDOME
CURB & FLASHINGP.T. BLOCKING
EPDM MECH WELLROOF
FIRE DAMPER
SKYLIGHT TUBEmin 26 GAGE
FIRE-RATED CEILINGRE: ASSEMBLIES
FLEXIBLE TRANSITION
DROPPED CEILINGRE: RCP
DIFFUSERRE: RCP
SKYLIGHT TUBESUPPORTS
8"
EPDM ROOFING ON BUILT-UPTAPERED INSULATION
METAL WALL PANEL
2 1/2" STEELCOLUMN BEYOND
16" LVL FLOOR JOIST
5"x12" LIGHTWEIGHTSTEEL TUBE 'BEAM'RE: SECTIONS
EPDM POST FLASHING BEYOND
STRUCTURAL METAL ANGLE @BOTTOM EDGE OF WALL PANEL
FASTEN METAL WALL PANELTO BEAM WITH METAL CLIP ANGLE
11/8" = 1'-0"
Roof Plan23/4" = 1'-0"
Roof Hatch Detail
33/4" = 1'-0"
Tube Skylight Detail
43/4" = 1'-0"
Mech Separation Wall
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A3.0Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
ELEVATIONS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
J I.1 I H F E.3 E D.6 D C B AG B.6
125
125
1'-6
"
METAL ROOF, TYPICAL
STUCCO WALLS, TYPICAL STONE VENEER ACCENT PRIVACY SCREEN@ COURTYARD
WOMEN'S ENTRANCE
CLERESTORY
MECH WELL
METALLOUVERS
ALTERNATESTUCCO COLOR
& TEXTURE
CONTROLJOINTS
STONE FACEDSEAT WALL
STUCCOTIMBERBEAM
STUCCO WALLFINISH
CLERESTORYWINDOWS
LIGHT FIXTURE,RE: ELEC
9 8 7 6 5 4 3 2 15.9 4.1
Main FloorEL: 100'-0"
125
125
122.5
125 29
'-11"
8'-0
"
9'-0
"
3'-2
"
METAL ROOF, TYPICALSTUCCO WALLS, TYPICAL
STONE VENEERACCENT WALLS
TIMBER TRUSS @ENTRY ROOF
FIBER CEMENTSIDING
TIMBER BEAMABOVE DOORBEYOND
ALTERNATESTUCCO COLOR &TEXTURE
CONTROL JOINTS
WINDOWS INCLERESTORY
BEYOND
AUTOMATIC DOOROPERATOR
KNOX BOX
AUTOMATIC DOOROPERATOR MOUNTEDIN STONE BEHIND
NOTE: 1 1/2" EPS AT STUCCO,1" XPS AT STONE & SIDING, TYP
3/4
12
MIN
. 30"
7'-0
"
CONCRETEPIER, RE: STRUCT
1/2" EXPANSIONJOINT
SIMPSON PVB10POST BASE w/5/8" DIA ANCHORBOLT
P.T. 2x FRAMING
STONE VENEER ONMORTAR/LATH
2" THK SANDSTONE CAP
P.T. PLYWOOD
LOG COLUMN
21/8" = 1'-0"
North Elevation
11/8" = 1'-0"
East Elevation31/2" = 1'-0"
Entry pier detail
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A3.1Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
ELEVATIONS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
A B C D D.6 E E.3 F H I I.1 JB.6 G
125
125
4'-11"
METAL ROOF, TYPICAL
STUCCO WALLS, TYPICAL
STONE VENEER ACCENT
TIMBER FENCE/SCREEN@ COURTYARD
AMBULANCE/STAFF/MEN'S ENTRY
LIGHT FIXTURERE: ELEC
MECH WELL
METAL LOUVER
ALTERNATE STUCCOCOLOR & TEXTURE
FIBER CEMENTSIDING
STUCCO IN GABLET+G
CONTROLJOINT, TYPELEC GEAR FDC
LAMBS TOUNGEROOF + OVERFLOW DRAINLEADERS
7'-0
"
1 2 3 4 5 6 7 8 94.1 5.9
125
125
121
8'-0
" TY
P.
METAL ROOF, TYPICAL
STUCCO WALLS, TYPICALSTONE WALL@ COURTYARD
3'x3' METAL LOUVER
LIGHT FIXTURERE: ELEC
NOTE: 1 1/2" EPS BEHINDSTUCCO, 1" XPS BEHINDSTONE AND SIDING, TYP
ALTERNATE STUCCOCOLOR & TEXTURE
PRIVACY FENCE,RE: DETAILS
PRIVACY WALLRE: DETAILS
4'-1
1"
7 1/
2"1"
1"2"
TYP
3"
8"2'
-6"
18"
@ N
ORT
H E
NTR
Y
1x6 BOARDS
1x3 BOARDS
3"x3"x_ STL TUBE
3"x3"x_ STL TUBE
LINE OF STONEWALL BEYOND
STONE VENEEREA. SIDE
2" SANDSTONE CAP(FLUSH w/ STONE VENEER)
PATIO
5'-2
" @
CO
URT
YARD
WAL
L
(2) #4 CONTINUOUS
2'-0" x 6" #4 DOWEL@ 48" o.c.
CONT. HORIZ. #4 @ 18" o.c.
VERT. #4 @ 48" o.c.
6" CONCRETEWALL
1'-4"
FIBER-CEMENT SIDINGFASTENED THROUGHFOAM TO SUBSTRATEPER MANUFACTURERSINSTRUCTIONS
1" XPS FOAM AT SIDING
ALT COLOR/TEXTUREEIFS STUCCO ON1 1/2" EPS
DRIP EDGE/CASINGBEAD BEHIND SIDING
EIFS WALLSYSTEM ON 1 1/2"EPS
FIBER-CEMENT SIDINGFASTENED THROUGHFOAM TO SUBSTRATEPER MANUFACTURERSINSTRUCTIONS
1" XPS FOAM AT SIDING
DRIP EDGE/CASINGBEAD BEHIND SIDING
STONE WATERTABLE, TYP
LIQUID APPLIEDAWB
STARTER BEAD/DRIPEDGE FLASHING
LIQUID APPLIEDAWB
EIFS WALLSYSTEM ON 1 1/2"EPS
STARTER BEAD/DRIPEDGE FLASHING
THIN STONE VENEERON MORTAR & LATH(FASTENED THRU FOAMTO STUD WALL BEHIND)ON 1" XPS
11/8" = 1'-0"
South Elevation
21/8" = 1'-0"
West Elevation33/4" = 1'-0"
Fence & Stone Wall Detail
41" = 1'-0"
Siding Details
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A4.0Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
SECTIONS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
2345789 15.9 4.1
T.O. WallEL: 110'-1 1/8"
Main FloorEL: 100'-0"
T.O. WallEL: 109'-1 1/8"
122.5
124
125
2A8.0
9A8.0
6
1'-0
"
1'-0
"
1'-0
"
BLOWN-ININSULATION AT
BOTTOM CHORDPLENUM
FIRE-RATED ROOF/CEILING ASSEMBLY
ACTCEILING
GYP SOFFIT,RE: RCP
BLOWN-IN WALLINSULATION
CABINETSBEYOND
FLUSH BEAMRE: STRUCT
COLUMN WRAPBEYOND
SUPPLY DUCT,RE: MECH
OFFICE RECEPTIONCONFERENCE OFFICE
9 8 7 6 5 4 3 2 15.9 4.1
T.O. WallEL: 110'-1 1/8"
Main FloorEL: 100'-0"
T.O. WallEL: 109'-1 1/8"
122.5
125
1'-0
"
1'-6
"
BLOWN-ININSULATION AT
BOTTOM CHORDPLENUM
FIRE-RATED ROOF/CEILING ASSEMBLY
ACT CEILINGBLOWN-IN WALLINSULATION
ACT CEILING
GYP CEILING
FLUSH BEAMRE: STRUCT ACT CEILING
CLERESTORYBEYOND
OFFICE BATH ADMISSIONS ROOMS LOCKERS OFFICE
A B C D D.6 E E.3 F H I I.1 J
Main FloorEL: 100'-0"
125
123
T.O. WallEL: 110'-1 1/8"
T.O. WallEL: 113'-8 1/2"
T.O. WallEL: 110'-1 1/8"
B.6 G
3A8.0
4A8.0
9'-8
"
BLOWN-ININSULATION ATBOTTOM CHORDPLENUM
FIRE-RATED ROOF/CEILING ASSEMBLY
ACT CEILING
CLERESTORYBEYOND
GABLE END TRUSSw/ DROPPED TOPCHORD
ENTRY ROOFBEYOND
MECHANICALWELL BEYOND
ENGINEERED TRUSSES,TYP
FRAMING ATSOFFIT BEYOND
LINE OF RATED CEILINGTRANSITION BEYOND,RE: 2/A4.0
SUPPLY DUCTRE: MECH
DROPPED TOP CHORDSRE: ROOF FRAMING
GIRDERTRUSS
OFFICEOFFICEOFFICEOFFICEHALLEXAMCONF/EXAMHALLLIVINGSLEEPINGROOM
SLEEPINGROOM OFFICE
11/8" = 1'-0"
Section21/8" = 1'-0"
Section
31/8" = 1'-0"
Section
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A4.1Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
SECTIONS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
9 8 7 6 5.9 5 4.1 4 3 2 1
T.O. BeamEL: 110'-0"
Main FloorEL: 100'-0"
T.O. BeamEL: 110'-0"
125
T.O. WallEL: 123'-6"
125
5A8.0
12A8.1
11A8.0
11A8.0
8 3/
4" H
EEL
13'-3
"
FIRE-RATED CEILING
NON-RATED GYPCEILING
FIRE-RATEDCEILING
GIRDER TRUSS
ENGINEEREDTRUSSES, TYP
SUPPLY DUCT,RE: MECH
WAITINGMEN'S ENTRY WOMEN'S ENTRYVESTIBULEVESTIBULE
SIM. OPP
LINEAR WALLFIXTURE + BEAM
WRAP, RE:DETAIL
1 2 3 4 4.1 5 5.9 6 7 8 9
T.O. WallEL: 110'-1 1/8"
Main FloorEL: 100'-0"
T.O. WallEL: 123'-9"
T.O. Mech FloorEL: 118'-11 1/2"
8'-0
5/8
"
ENGINEERED TRUSSESI-JOIST FLOOR
LOUVER, RE:ELEVATIONS
BLOWN-ININSULATION
CONCRETE SLABON GRADE
SUPPLY DUCTRE: MECH
GYP SOFFIT
BLOCKING FOR MOVABLEPARTITION SUPPORT
SOFFIT FOR MOVEABLEPARTITION TRACK, BEYOND
WOMEN'SLIVING
MEN'SLIVING
MEN'SSLEEPING
WOMEN'SSLEEPING
125
125
123
10A8.1
WALL/SUPPORT FORMOVEABLE PARTITIONS
J I.1 I H F E.3 E D.6 D C B A
T.O. WallEL: 110'-1 1/8"
Main FloorEL: 100'-0"
T.O. Mech FloorEL: 118'-11 1/2"
T.O. WallEL: 110'-1 1/8"
B.6G
6A8.0
7A8.0
12A8.0
13'-3
"
1'-2
"
1'-6" 1'-0"
11'-3
"
TIMBER ENTRY
ENGINEERED TRUSSESVAULTED CEILINGIN RECEPTION
GYP CEILING
ACT CEILING
CLERESTORYROOF
ACT CEILING ELEVATED FLOOR
I-JOIST MECHWELL FLOOR
TRIM 'BEAM' LOUVER BEYOND
BLOWN-IN INSULATION
GABLE END TRUSSw/ DROPPED TOP CHORDLIGHT FIXTURES
BEYOND
VESTIBULERECEPTION
ADMISSIONS WAITING MEDS SLEEPINGNURSE'SSTATIONMEDS
PARTITIONSTGHALLBUSINESS
CENTER
THERMO-PLY ATATTIC SIDE OF
EXPOSED VERTICALINSULATION, TYP
LINE OF T.O.WALL BEYOND
11/8" = 1'-0"
Section21/8" = 1'-0"
Section
31/8" = 1'-0"
Section
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A4.2Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
SECTIONS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
2345678 5.9 4.1
T.O. WallEL: 110'-1 1/8"
Main FloorEL: 100'-0"
T.O. WallEL: 110'-1 1/8"
125
123
T.O. WallEL: 109'-8"
1A8.0
3A3.1
10A8.1
WALL SUPPORT FORMOVEABLE PARTITIONS
STONE WALL
ACT CEILING
FIRE-RATEDCEILING
MEN'SSLEEPING
WOMEN'SSLEEPING
SEMI-PRIVATEROOM
SEMI-PRIVATEROOMPATIO PATIO
INFILL FRAMINGCONTINUOUS RATEDCEILING ABOVE
2 3 4 5 6 7 84.1
T.O. WallEL: 110'-1 1/8"
Main FloorEL: 100'-0"
T.O. BeamEL: 109'-0"
125
5.9
3A3.1
1A8.1
8'-0
"
PRIVATEROOMHALL
PRIVATEROOMPATIO HALL PATIO
GABLE ROOFBEYOND
LINE OF SLOPEDCEILING IN SLEEPING ROOM
BEYOND
ENGINEERED TRUSSES
TIMBER BEAM
GYP CEILING
J I.1 I H F E.3 E D.6 D C B A
Main FloorEL: 100'-0"
125
123T.O. Wall
EL: 110'-1 1/8"
Truss BearingEL: 113'-8 1/2"
T.O. WallEL: 109'-1 1/8"
T.O. BeamEL: 109'-2"
B.6G
3A8.0
11A8.0
8'-0
"
4 3/
4"
GABLE END TRUSSw/ DROPPED TOP
CHORD
ENGINEEREDTRUSSES, TYP
PORCH ROOF
DROPPED NON-RATED GYPCEILING IN BATH
ACT CEILING
HALL HALLSTAFF
LOUNGE
BATHROOM
COVEREDPATIO PATIOLIVING
SIM.
T+G WOODCEILING
11/8" = 1'-0"
Section21/8" = 1'-0"
Section
31/8" = 1'-0"
Section
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A4.3Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
SECTIONS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
9 8 7 6 5 4.1 4 3 2 1
Main FloorEL: 100'-0"
Mech. FloorEL: 118'-11 1/2"
125
T.O. HEADEREL: 113'-8 1/2"
Dropped CeilingEL: 109'-0"
5.9
8A8.0
2A2.1
I-JOIST FLOOR
PARTIALROOF/EAVE
'BEAM' BEYONDINSULATED HATCHAT LADDER ACCESS
DROPPEDGYP CEIING
ACT CEILINGS
DROPPEDGYP CEIING
FIRE-RATEDCEILING
ACCESSLADDER
ACT CEILINGSBLOWN-IN INSULATIONAT BOTTOM CHORD
FIRE-RATEDCEILING
HEADERRE: STRUCT
INSTALL FLOOR TO FLOOR TIES:SIMPSON LFTA OR CS16 @ 5'-4" o.c.w/ 12" END LENGTH (CS16)
SIMPSON H2.5A, TYP
MECH WELL
MEN'SSLEEPING
WOMEN'SBATHROOMNURSE'S
STATION
WOMEN'SSLEEPING
ACT CeilingEL: 112'-0"
ACT CeilingEL: 111'-6"
2 3 4 4.1 5 5.9 6 71 8 9
T.O. BEAMEL: 109'-2"
BLOWN-IN INSULATIONAT BOTTOM CHORD
ENGINEERED TRUSSES, TYP
WOMEN'SSLEEPING
MEN'SSLEEPING
SEMI-PRIVATE SEMI-PRIVATE
COURTYARDCOURTYARD
ACT CEILINGS
ENGINEEREDTRUSSES, TYP
SOFFIT TOBOTTOM CHORD FIRE-RATED
CEILING
SOFFIT, BEYOND
CD
FINISH CEILINGEL: 109'-0"
T.O. WALLEL: 111'-0"
125
SPRAY FOAM FULLCAVITY AT EXTERIOBATH WALLS
MEN'SBATHROOM
BLOWN-IN INSULATIONAT BOTTOM CHORD
FIRE-RATEDCEILING
DROPPEDGYP CEIING
ENGINEEREDTRUSSES
6 5.9 5 4.1 4
T.O. BEAMEL: 111'-1"
T.O. BEAMEL: 114'-3"
7 3
4x8 RAFTERS
BEAMSRE: STRUCTURAL
2x T&G ROOFDECKING
11/8" = 1'-0"
Section
31/8" = 1'-0"
Section
21/8" = 1'-0"
Section
41/8" = 1'-0"
Section
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A5.0Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
DOOR SCHED &DETAILS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
71 1/2" = 1' - 0"
DETAIL81 1/2" = 1' - 0"
DETAIL
91 1/2" = 1' - 0"
DETAIL
21 1/2" = 1' - 0"
DETAIL 11 1/2" = 1' - 0"
DETAIL31 1/2" = 1' - 0"
DETAIL41 1/2" = 1' - 0"
DETAIL51 1/2" = 1' - 0"
DETAIL61 1/2" = 1' - 0"
DETAIL
101 1/2" = 1' - 0"
DETAIL
111 1/2" = 1' - 0"
DETAIL
RIGID INSUL.
FLASHING
DRIP EDGE/STOP BEADFLASHING
DRIP EDGE/STOP BEAD
DRIP EDGE/STOP BEADFLASHING
METAL K/D CASING, TYP
WALL FRAMING - RE: PLAN
HIGH IMPACTCORNER GUARD
INTERIOR EXTERIOR
HOLLOW METAL DOORHEAD @ STUCCO
HOLLOW METAL DOORJAMB @ STUCCO
STORE FRONT DOOR HEAD@ STUCCO
STORE FRONT DOORTHRESHOLD
EXTERIOR
HOLLOW METAL DOORTHRESHOLD @ TILE ENTRY
INTERIOR DOOR HEAD/JAMBWOOD FRAME
CLAD FRAME FIBERGLASS DOORTHRESHOLD
INTERIOR EXTERIOR
CLAD FRAME FIBERGLASS DOORHEAD @ STUCCO
STORE FRONT JAMB@ STUCCO
INTERIOR
INTERIOR DOOR JAMB/HEADERMETAL K/D FRAME
CLAD FRAME DOORJAMB @ STUCCO
METAL K/D DOOR JAMB
DOOR SWEEP
TILE FLOORHALF SADDLEACCESSIBLE THRESHOLD
STUCCO SYSTEM
SHEATHING
HEADER, RE: STRUCTURALSTUD WALL
GYP BOARD
SEALANT
H.M. DOOR JAMB
SEALANT
SHEATHING
GYP BOARD
WALL STUDS
H.M. DOOR JAMB
STUCCO SYSTEM
SEALANT
SHEATHING
GYP BOARD
INSULATION
STUCCO SYSTEM
GYP BOARD
STUD WALL HEADER, RE: STRUCTURAL
PLY. SHEATHING
RETURN GYP TODOOR FRAME
STORE FRONT DOOR
STUCCO
DOOR SWEEPTILE FLOOR
STUCCO BEYOND
CASINGWOOD DOOR JAMB
WALL FRAMING - RE: PLAN
GYP BOARD
DOOR FRAMEBY DOOR MFR
WALL FRAMING
FIBERGLASS DOOR
STUCCO
ACCESSIBLE THRESHOLD
DOOR SWEEPFINISH FLOOR
STUCCO SYSTEM
INSUL.
CASINGWOOD DOOR JAMB
WALL STUDS
GYP BOARD
SHEATHING
SEALANT
DOOR FRAMEBY DOOR MFR
SEALANT
GYP BOARD
2x6 STUD WALL HEADER, RE: STRUCTURAL
SHEATHING
STUCCO SYSTEM
RETURN GYP TODOOR FRAME METAL DRIP EDGE
METAL DRIP EDGE
DOOR FRAME BY DOOR MFR
SEALANT
STUCCO SYSTEM
1x CASING
GYP BOARD
METAL DRIP EDGE
HALF SADDLEACCESSIBLE THRESHOLD
RIGID INSUL.
LIQUID APPLIED AIRWEATHER BARRIER
LIQUID APPLIED AIRWEATHER BARRIER
DOOR SCHEDULE
ID
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
121
122
122a
123
123a
124
125
126
127
128
129
130
131
132
133
PAIRDOORS
PR 3'-0"
PR 3'-0"
PR 3'-0"
PR 1'-6"
PR 1'-6"
SIZE
W
8'-6"
6'
3'
6'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'-6"
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'
3'-6"
HT
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
THK
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
FRM
4"
4 7/8"
4 7/8"
4 7/8"
4 3/4"
4 7/8
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
6 3/4"
4 7/8"
4 7/8"
6 3/4"
6 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 7/8"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
6 3/4"
MATERIAL
DR
AL
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
H.M.
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
FRM
AL
WD
WD
WD
WD
WD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
WD
KD
KD
KD
KD
KD
KD
KD
KD
WD
KD
KD
KD
KD
KD
KD
KD
FIRERATING
20 MIN
HDWRE
HW-1
HW-1A
HW-5
HW-10
HW-6
HW-2
HW-8
HW-5
HW-5
HW-5
HW-5
HW-2
HW-7
HW-6A
HW-7
HW-7
HW-5A
HW-2
HW-2B
HW-8
HW-5A
HW-5
HW-9
HW-5
HW-9
HW-6A
HW-6A
HW-2
HW-5
HW-5
HW-5
HW-5
HW-5
HW-5
HW-5A
STYLE
FULL LITE
FULL LITE
FULL LITE
FULL LITE
FLUSH
FLUSH w/VISIONLITE
FLUSH
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH
FLUSH
FLUSH
FLUSH
FLUSH w/VISIONLITE
FLUSH w/HALF LITE
FLUSH w/HALF LITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH -VISIONLITE
FLUSH
FLUSH -VISIONLITE
FLUSH
FLUSH
FLUSH
HALF LITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
FLUSH w/VISIONLITE
VIEWDETAIL
HEAD
8/A5.0
10/A5.0
10/A5.0
10/A5.0
10/A5.0
10/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
3/A5.0
10/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
10/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
JAMB
9/A5.0
10/A5.0
10/A5.0
10/A5.0
10/A5.0
10/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
2/A5.0
10/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
10/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
SILL
7/A5.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1/A5.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
LOCATION
ENTRY
ENTRYVESTIBULE
MEET + GREET
MEETINGROOM
MEETING RMBATH
MEETING RMHALL
STORAGE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STAFF HALL
STAFF BATH
STAFFLOCKERS
STAFFLOCKERS
NORTH HALL
NORTH(WOMEN'S)
ENTRY
NORTH ENTRYVESTIBULE
STAFF LOUNGE
WMWAITING/HALL
ADMISSION
ADMISSIONSCL
ADMISSION
ADMISSIONSCL
RESTROOM
RESTROOM
MEET + GREET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MNWAITING/HALL
NOTES
13" SIDELITE EACH SIDE
15" SIDELITE EACH SIDE
15" SIDELITE
1" UNDERCUT
1" UNDERCUT
1" UNDERCUT
1" UNDERCUT
1" UNDERCUT
1" UNDERCUT
12" SIDE LITE
DOOR SCHEDULE
ID PAIRDOORS
SIZE
W HT THK FRM
MATERIAL
DR FRM
FIRERATING HDWRE STYLE VIEW
DETAIL
HEAD JAMB SILL
LOCATION NOTES
134
135
136
136a
137
138
139
140
141
142
143
144
144a
145
146
147
148
149
150
151
152
153
154
155
156
157
157a
158
159
160
161
162
163
164
PR 3'-0"
PR 3'-0"
PR 3'-0"
3'-0" OP
PR 3'-0"
PR 3'-0"
6'-4"
6'-4"
3'-6"
3'
3'-6"
3'
3'
3'
3'
3'-6"
3'
3'
3'
6'
6'
3'
3'
3'
3'
3'
3'
3'
3'
6'
6'
3'
3'
3'
3'-6"
3'
3'
3'
3'
3'-6"
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
0'-1 37/64"
0'-1 37/64"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
0'-1 3/4"
4"
4"
6 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
6 3/4"
6 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
6 3/4"
6 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
6 3/4"
6 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
4 3/4"
6 3/4"
6 3/4"
4 3/4"
4 3/4"
4 3/4"
AL
AL
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
F.G.
SCW
SCW
SCW
F.G.
F.G.
SCW
SCW
SCW
F.G.
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
SCW
AL
AL
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
CLADWD
KD
KD
KD
CLADWD
CLADWD
KD
KD
KD
CLADWD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
20 MIN
20 MIN
20 MIN
HW-1B
HW-1C
HW-8
HW-8
HW-8
HW-8
HW-8
HW-5
HW-5
HW-8
HW-8
HW-6B
HW-6A
HW-10 A
HW-4
HW-7
HW-7
HW-7
HW-3
HW-3
HW-7
HW-7
HW-7
HW-4
HW-10 A
HW-6B
HW-6A
HW-8
HW-8
HW-5
HW-5
HW-8
HW-8
HW-8
FULL LITE
FULL LITE
FLUSH
FLUSH
FLUSH
FLUSH w/1/2 LITE
FLUSH w/1/2 LITE
FLUSH
FLUSH
FLUSH w/1/2 LITE
FLUSH w/1/2 LITE
FLUSH
FLUSH
FRENCH
PATIO
FLUSH w/1/2 LITE
FLUSH w/1/2 LITE
FLUSH w/1/2 LITE
HALF LITE
HALF LITE
FLUSH w/1/2 LITE
FLUSH w/1/2 LITE
FLUSH w/1/2 LITE
PATIO
FRENCH
FLUSH
FLUSH
FLUSH w/1/2 LITE
FLUSH w/1/2 LITE
FLUSH
FLUSH
FLUSH w/1/2 LITE
FLUSH w/1/2 LITE
FLUSH w/VISIONLITE
8/A5.0
8/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
5/A5.0
11/A5.0
11/A5.0
11/A5.0
5/A5.0
5/A5.0
11/A5.0
11/A5.0
11/A5.0
5/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
9/A5.0
9/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
6/A5.0
11/A5.0
11/A5.0
11/A5.0
6/A5.0
6/A5.0
11/A5.0
11/A5.0
11/A5.0
6/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
11/A5.0
7/A5.0
7/A5.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4/A5.0
N/A
N/A
N/A
4/A5.0
4/A5.0
N/A
N/A
N/A
4/A5.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
AMBULANCEENTRY
AM. ENTRYVESTIBULE
MECHANICAL
IT
MENWAITING/MED
MED RM
MED RM
EXAM RM
EXAM RM
MEN'SSLEEPING RM
CONF. ROOM
DETOXRESTRM
DETOXPRIVATERESTRM
LIVING
LIVING
SLEEPING RM
SLEEPING RM
PRIVATESLEEPING
SLEEPING RMEXIT
SLEEPING RMEXIT
PRIVATESLEEPING
SLEEPING RM
SLEEPING RM
LIVING
LIVING
DETOXRESTRM
DETOXPRIVATERESTRM
CONF. ROOM
WOMEN'SSLEEPING RM
EXAM RM
EXAM RM
MED RM
MED RM
WMWAITING/MED
1" UNDERCUT
INTEGRAL BLINDS
INTEGRAL BLINDS
INTEGRAL BLINDS
INTEGRAL BLINDS
1" UNDERCUT
1" UNDERCUT
18" SIDE LITE EA. SIDE
CLAD FRAME / 3'0" DOOR w/ FIXEDSIDELIGHT
INTEGRAL BLINDS / 1" UNDERCUT
INTEGRAL BLINDS / 1" UNDERCUT
INTEGRAL BLINDS / 1" UNDERCUT
CLAD FRAME
CLAD FRAME
INTEGRAL BLINDS / 1" UNDERCUT
INTEGRAL BLINDS / 1" UNDERCUT
INTEGRAL BLINDS / 1" UNDERCUT
CLAD FRAME
18" SIDE LITE EA. SIDE
1" UNDERCUT
1" UNDERCUT
INTEGRAL BLINDS
INTEGRAL BLINDS
INTEGRAL BLINDS
INTEGRAL BLINDS
HARDWARE SCHEDULE: SEE SPECIFICATIONS
SOLID COREHOLLOW COREHOLLOW METALFIBERGLASS
WOODMOLDED SKIN
KNOCK DOWNHOLLOW METAL (WELDED FRAME)
KEY
S.C.H.C.H.M.F.G.
WDMS
KDMTL
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A5.1Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
WINDOW SCHED& DETAILS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
11 1/2" = 1' - 0"
DETAIL21 1/2" = 1' - 0"
DETAIL31 1/2" = 1' - 0"
DETAIL61 1/2" = 1' - 0"
DETAIL
71 1/2" = 1' - 0"
DETAIL81 1/2" = 1' - 0"
DETAIL91 1/2" = 1' - 0"
DETAIL
41 1/2" = 1' - 0"
DETAIL51 1/2" = 1' - 0"
DETAIL
3/4"
TAPER SILL TO DRAINLIQUID APPLIED AIR &WEATHER BARRIER MEMBRANEOVER DRIP EDGE FLASHING
WINDOW DETAILS BY MFR
RETURN GYP TOPAND SIDES
HEADER - RE: STRUCT
1 1/2" EPS INSULATION
STRUCTURAL WALL SHEATHING
WINDOW DETAILS BY MFR
CASING/STOP BEAD
BACKER ROD AND SEALANT
BACKER ROD AND SEALANT
STUCCO SYSTEM
1x SILL
1 1/2" EPS INSULATION
STRUCTURAL WALL SHEATHING
CASING/STOP BEAD
WINDOW DETAILS BY MFR
BACKER ROD AND SEALANT
STUCCO SYSTEM
1 1/2" EPS INSULATION
STRUCTURAL WALL SHEATHING
RETURN GYP TOPAND SIDES
SILL STONE
WINDOW DETAILS BY MFR
BACKER ROD AND SEALANT
STONE FACADE
1x SILL
1" EPS INSULATIONMECHANICALLY FASTENEDTHRU INSULATION TO STUDWALL BEHIND
STRUCTURAL WALLSHEATHING
SINGLE PANELFIELD GLAZED
1x WALL CAP 1x STOPS
2x WALL
SINGLE PANELFIELD GLAZED
1x STOPS
2x WALLHEADER, RE: STRUCTURAL
SINGLE PANELFIELD GLAZED
1x STOPS
2x WALL
1x WALL CAP
1x WALL CAP
STUCCO SYSTEM
1x APRON
TAPER SILLENDS
1/2" MORTAR & LATH
1x APRON
TAPER SILLENDS
1x2 CASING, TYP
1x3 CASING, TYP
1x3 CASING, TYP
FIBER-CEMENT LAP SIDINGFASTENED THROUGH INSULTO WALL BEHIND
NAILER
SEALANT
1" XPS INSULATIONMECHANICALLY FASTENED
1 1/2"x3 1/2" FIBER CEMENTSIDING, RIPPED IN HALF
1x JAMBEXTENSION
CASING
OPENING FLASHINGDETAILS PER EIFS/AWBSYSTEM MANUFACTURER
WINDOW. DETAILS BY MFR
BACKER ROD AND SEALANT
NAILER
1x SILL
1" XPS INSULATIONMECHANICALLY FASTENED
STRUCTURAL WALL SHEATHING
PAN FLASHING
TAPER SILLENDS
1x4 APRON
LIQUID APPLIED AWB
2x4 ARTISAN TRIM, RIPPEDDOWN +/- 1"
FIBER-CEMENT LAP SIDING
WINDOW SILL@ STUCCO
WINDOW JAMB@ STUCCO
WINDOW HEAD@ STUCCO
WINDOW SILL@ STONE
INTERIOR WINDOW SILLFIXED FIELD GLAZING
INTERIOR WINDOW HEADFIXED FIELD GLAZING
INTERIOR WINDOW JAMBFIXED FIELD GLAZING
WINDOW JAMB@ SIDING
WINDOW SILL@ SIDING
WINDOW SCHEDULE
ID
A
B
C
D
E
F
G
H
I
J
K
L
UU
VV
WW
XX
YY
ZZ
SIZE
W
5'
5'
7'-6"
7'
7'
2'-6"
12'
6'
5'
4'
2'
3'
2'
5'
3'
5'
2'-8"
5'
HT
3'-6"
5'
5'
5'
3'-6"
3'-6"
5'
5'
2'
3'-6"
3'-6"
3'
5'
3'-9"
5'
5'
5'
5'
HEADHEGHT
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
6'
7'-2"
7'-2"
9'
9'
7'-2"
7'-2"
TYPE
SLIDER
SLIDER
SLIDER
SLIDER
SLIDER
FIXED
SLIDER
SLIDER
SLIDER
SLIDER
SLIDER
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
VIEWDETAIL
HEAD
3/A5.1
3/A5.1
3/A5.1
3/A5.1
3/A5.1
3/A5.1
3/A5.1
3/A5.1
3/A5.1
3/A5.1
3/A5.1
3/A5.1
8/A5.1
8/A5.1
8/A5.1
8/A5.1
8/A5.1
8/A5.1
JAMB
1/A5.1
1&4/A5.1
1&4/A5.1
1/A5.1
1/A5.1
4/A5.1
4/A5.1
1/A5.1
1&4/A5.1
1/A5.1
1/A5.1
9/A5.1
9/A5.1
9/A5.1
9/A5.1
9/A5.1
9/A5.1
SILL
2/A5.1
5&6/A5.1
5/A5.1
6/A5.1
2/A5.1
2/A5.1
2/A5.1
2/A5.1
2/A5.1
6/A5.1
6/A5.1
2/A5.1
7/A5.1
7/A5.1
7/A5.1
7/A5.1
7/A5.1
7/A5.1
NOTES
CLERESTORY
MATCH HD. HT. TO ADJ. DOOR
MATCH HD. HT. TO ADJ. DOOR
MATCH HT. TO ADJ. DOOR / DBL PANE
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A6.0Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
RCP
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
9A8.1
2A8.0
3/A4.0 3/A4.0
3/A4.13/A4.1
3/A4.23/A4.2
2'-0
"
4'-0"
4'-0"
3'-0
"3'
-0"
3'-0"
2/A4.3 2/A4.3
3/A4
.33/
A4.3
4/A4
.34/
A4.3
SMOKE BARRIER INATTIC ABOVE CEILING
CLERESTORYABOVE
T+G CEILINGAT COVERED PORCH
COLUMNS
COLUMN
COLUMN
SOFFIT HGT8'-0"
PARTITION TRACK
PANEL STORAGEPARTITIONTRACK
SOFFIT @ 10'-0"RE: SECTIONS
RECESSEDCAN, RE: ELEC
WALL MOUNTEDCEILING UPLIGHT
RECESSED CANS INRATED CEILING, PROVIDEFIRE-RATED CEILINGENCLOSURE, RE: ELEC.
WALL SCONCERE: ELEC
DISPLAYLIGHTING
WALL SCONCEUP LIGHT
LINEAR FIXTURE
SOFFIT
FIRE RATEDACCESS PANEL
SKYLIGHTDIFFUSERS,TYP. OF (2)
1X6 T&GSOFFIT
1x6 T&GSOFFIT
STUCCOSOFFIT, TYP.
SOFFIT VENT, TYP., RE: DETAILS
BOX SOFFIT ENCLOSURE, TYP.
24" EAVE,TYP. U.O.N.
SOFFIT VENT, TYP.
GYP. CEILING,TYPICAL
ACT CEILING,TYPICAL
EXHAUST FAN,RE: MECH.
12"x12"ACCESS PANEL,RE: MECH.
24"x24"ACCESS PANEL,
TYP. OF (6)RE: MECH.
RECESSEDRETRACTABLE SCREEN
SLOPE UP
3:12
SLOPE UP
3:12
SLO
PE U
P
3:12
SLO
PE U
P
3:12
CEILING HT: 9'-0"
CEILING HT: 9'-0"CEILING HT: 11'-6"
CEILING HT: 8'-0"
CEILING HT: 9'-0"CEILING HT: 9'-0"
CEILING HT: 9'-0"
CEILING HT:12'-0"
CEILING HT: 8'-0"
CLG HT: 8'-0"
CLG HT: 9'-0"
CLG HT: 12'-0"
CEILING HT: 8'-0"
CLG HT: 23'-6"
CLG HT: 8'-0"
CLG HT: 9'-0"
SLO
PE U
P
4:12
CEILING HT: 8'-0"
CEILING HT: 9'-0"CLG HT: 8'-0"
SLO
PE U
P
4:12
CLG HT: 8'-0"
CLG HT: 8'-0"
CEILING HT: 8'-0"
CLG HT: 8'-0"
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
CLG HT: 12'-0"
CEILING HT: 13'-8"
CLG HT: 8'-0"
CLG HT:8'-0"
CEILING HT: 9'-0"
CLG HT:8'-0"
CLG HT: 8'-9"
OS
OS
OS
OS
OS
OS
2/A4
.02/
A4.0
1/A4
.21/
A4.2
2/A4
.22/
A4.2
1/A4
.01/
A4.0
2/A4
.12/
A4.1
1/A4
.11/
A4.1
1/A4
.31/
A4.3
T+G WOODCEILING
EXPOSED 2xPINE DECKING
11/8" = 1'-0"
Reflected Ceiling Plan
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A6.1Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
REFLECTED FIRERATED CEILING
PLAN
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
3/A4.0 3/A4.0
3/A4.13/A4.1
3/A4.23/A4.2
2/A4.3 2/A4.3
3/A4
.33/
A4.3
4/A4
.34/
A4.3
2/A4
.02/
A4.0
1/A4
.21/
A4.2
2/A4
.22/
A4.2
1/A4
.01/
A4.0
2/A4
.12/
A4.1
1/A4
.11/
A4.1
1/A4
.31/
A4.3
SLOPED CEILINGRE: SECTIONS
SLOPED CEILNGRE: SECTIONS
36" x 36"ROOF HATCH
RTU DUCTOPENINGSRE: MECH
1HR COL WRAPRE: DETAIL
1HR BEARING WALLSAT MECH WELL
CONTINUE RATEDCEILING MEMBRANEACROSS ALL CEILING
HT CHANGES
FULL HEIGHT WALLSAT SLOPED RECEPTIONCEILING, 1-HR RATEDNON-BEARING WALLS,RE: SECTIONS
1HR BEARING WALL
1HR BEARING WALL
FULL HEIGHT WALLSAT SLOPED LIVINGCEILING, 1-HR RATEDNON-BEARING WALLS,RE: SECTIONS
SKYLIGHT,TYP OF (2)
EXHAUST FANDUCT, TYP.
FULL HEIGHTSMOKE BARRIER
1HR WALL
20"x30" FIRE RATEDATTIC ACCESS PANEL
IN JANITOR-131
20"x30" FIRE RATEDATTIC ACCESS PANEL
IN ADMISSION-117
DOUBLE LAYER GYP.FIRE-RATED CEILING,RE: ASSEMBLIES@ RECEPTION
TYPICAL CEILING:5/8" GYP. ON RESILIENTFURRING CHANNELS,RE: ASSEMBLIES
CEILING HT: 9'-0"
CEILING HT: 10'-0"
CEILING HT: 11'-6"
CLG HT: 10'-0"
CEILING HT: 11'-0"
CEILING HT: 13'-8"
CLG HT: 10'-0"
CLG HT: 10'-0"
CLG HT: 12'-0"
CLG HT: 12'-0"
CLG HT:23'-6"
CEILING HT: 17'-6"
CEILING HT: 13'-8"
CEILING HT: 11'-0"
1'-4" o.c.
TWO LAYERS OF MIN 1/2"TYPE "X" GYP BOARD CEILING(see assembly listing for fasteningrequirements)
3/4" T&G OSBFLOOR SHEATHING
'I' JOISTsMAX 16"o.c.
FIBERGLASS INSULATIONSUPPORT TO MAINTAIN AIRGAP BETWEEN JOIST & GYP
min 0.019 THK GALV STEELRESILIENT CHANNELS @ 24"o.c.FASTEN TO JOISTS w/1 5/8" DRYWALL SCREWS
2x FIREBLOCKED STUDSMAX. 16"o.c. SPACING
5/8" TYPE-XGYP BOARD
ACOUSTIC INSULATION, TYP
LOOSE FILL INSULATION
(1) LAYER 5/8" GYP BOARD:NATIONAL GYPSUMFIRE-SHEILD C orUSG FIRECODE C
ENGINEEREDWOOD TRUSS
1/2" RESLIENT FURRINGCHANNELS @ 12"o.c.FASTEN TO TRUSS w/1 1/4" TYPE S or W SCREWS
(2) LAYERS,5/8" TYPE 'X' GYP BOARD
STEEL COLUMN,RE: STRUCT
NON-RATEDPARTITION
1 1/2" EPS INSULATION
LIQUID APPLIED AIR &WEATHER BARRIERMEMBRANE
STRUCTURAL WALLSHEATHING
CAVITY INSULATION
5/8" TYPE 'X' GYPBOARD
WOOD STUDS
ENGINEEREDWOOD TRUSS
(2) LAYERS 5/8" GYP BOARD:FIRE-RATED TYPE-C
LOOSE FILL INSULATION
2x STUD WALL16"o.c. SPACING
5/8" GYPBOARD EA SIDE
ACOUSTIC INSULATION, TYP
MIN. 2x6 STUD FRAMING@ MAX. 24" o.c. SPACING
5/8" GYPBOARD
RATED WALL,UL - U305
(2) 2x BLOCKS @ WALLINTERSECTION, w/ MIDSEAM ALIGNED TO FACEOF RATED STUD WALL
NON-RATEDPARTITION WALL
INTERUPTINGRATED GYPSUM
EIFS FINISH SYSTEM,RE: ELEVATIONS & DETAILSFOR ALT. WALL FINISHES
1-HR FIRE RATEDMECH. WELL FLOOR-CEILINGAMERICAN WOOD COUNCIL
WIJ-1.7
1 HR. BEARING WALL& SMOKE BARRIERUL FILE NO. - U305
1-HR FIRE RATEDROOF/CEILING, TYPICAL
GA FILE NO. RC 2603
1 HR. COLUMNUL FILE NO. - X528
TYPICAL EXTERIOR WALLPLAN VIEW
1-HR EXTERIOR WALLUL FILE NO. - U356
(RATED FROM INSIDE ONLY)
1-HR FIRE RATEDROOF/CEILING, RECEPTIONIBC TABLE 720.1 (3) - 21-1.1
TYPICAL INTERIORNON-RATEDPARTITIONPLAN VIEW
TYPICAL NON-RATEDGYPSUM CEILING
1-HR WALL/ NON-RATEDWALL INTERSECTION
PER UL FILE NO. - U305PLAN VIEW
13/32" = 1'-0"
Reflected Fire Rated Ceiling Plan2
1" = 1'-0"
Assemblies
ALLOWED UNPROTECTED MEMBRANEPENETRATIONS
LISTED ELECTRICAL BOXES
FIRE SPRINKLERS COVERED w/ESCUTCHEON PLATE
ALLOWED PROTECTED MEMBRANEPENETRATIONS
MAX. 100sq in IN 100sfCONDUIT, PIPE, ELEC BOXES, VENTS,WHERE ANNULAR SPACE IS FILLED w/
APPROVED FIRE CAULK
STAGGER ELECTRICAL BOXES TOAVOID THROUGH PENETRATIONS IN
RATED WALLS
DUCTWORK PENETRATINGRATED WALLS THAT ARE NOT SMOKE
BARRIERS OR SMOKE PARTITIONSSHALL NOT BE REQUIRED TO BEDAMPERED IF WALL CAVITY IS
PROTECTED WITH DRYWALL WRAP.
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A7.0Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
INTERIORELEVATIONS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
2'-9
"
ACCESSIBLE SINKMAX 34" TOP OFBOWL
SB48 F1REF24
4" SOLID SURFACEBACK & SIDE SPLASH
SOLID SURFACECOUNTERTOP
2'-9
"1'
-6"
3'-6
"
FILLER ATWALL
REFRIGERATORBY OWNER
SB42 B36DB18
WC3642 WC1842
REF36
4" LAMINATEBACK & SIDESPLASH
LAMINATECOUNTERTOP
4" BASE BYLOCKER MFR
LOCKERS
FILLER BY LOCKERMFR
SLOPED LOCKERTOP
3'-0"
2'-1
0"4"
24"x36" MIRROR
PIPE GUARD,TYP
WALL MOUNT SINK-ADA COMPLIANT
RE: TYPICAL BATHFOR SIDE BAR LOCATIONS
CERAMIC TILEWAINSCOT, ALL
WALLS
SOAP DISP.
P.T. DISP.MAX. 48" TOOPERATOR
PROVIDE BLOCKINGIN WALL FOR GRABBARS, TYP 3'-4"
3'-4
"1'
-6"
1'-0" 3'-6"
2'-1
1"
5'-0
"
8"
1'-4
"
GRAB BARS
CERAMIC TILEWAINSCOTALL WALLS
T.P. DISP.3'-0"
2'-9
"4" 5'-0
"
24"x36"MIRROR
CERAMIC TILEWAINSCOT, ALLFOUR WALLS
LAMINATECOUNTERTOP
SOAP DISP.
P.T. DISP.MAX. 48" TOOPERATOR
LAV36
2'-0" MIN
PROVIDE BLOCKINGIN WALL FOR GRABBARS, TYP
1x4 CHAIR RAIL(match backsplash height)
TYP ALL WALLS IN MEETING ROOM
ALT PAINT COLORABV + BELOW RAIL
1x6 WOODBASE, TYP
WOOD TRIMRE: DETAIL GYP SOFFIT
B45F1 F3/4
3 1/2" SOLID SURFACEBACK & SIDE SPLASHES
SOLID SURFACECOUNTERTOP
2'-9
"
1x6 WOOD BASEWINDOW SILL &APRON, RE:DETAILS
1x4 CHAIR RAIL
ACCESSIBLEHEIGHT CABINETS
ALT PAINT COLORABV + BELOW RAIL
1x4 WOODCASING
LINE OF COFFER INFRONT, RE: RCP
B42 F1SB42F1
3 1/2" SOLID SURFACEBACK & SIDE SPLASH
SOLID SURFACECOUNTERTOP
2'-6
" 3'-6
"
STEEL TROWEL GYPTEXTURE ON WALLBEYOND, RE: SPEC
'BARK-ON' 8-INCHDIAMETER ASPEN
LOGS, TYP OF 4
RECLAIMED,REFINISHED BOARDTRIM, WIDTHS VARY
1x8 WOOD BASE,STAINED
SOLID SURFACECOUNTER
ACCESSIBLE HEIGHTCOUNTER
PICTURE RAIL
RECEPTION
7'-5
3/4
"
3'-6
"
1x4 STAINEDWOOD CASING
WOOD BASEBEYOND
1x8 WOODBASE
'GREY-WASHED'WOOD CEILING
LIGHT FIXTURERE: ELEC
'BARK-ON' ASPENLOG BEYOND
1x6 PICTURERAIL
RECLAIMED,REFINISHED BOARD
TRIM, WIDTHS VARY
ALT PAINTCOLOR ABV +BELOW RAIL
RECEPTION 8'-6
3/8
"
3'-0
"
2'-6"
1x6 PICTURE RAILALIGN TOP w/DOOR TRIM
STONE VENEER ON FIRE-RATED GLASS-MATGYPSUM BACKING
T.O. WALLWALL SCONCERE: ELEC
WOOD CEILING
SEE DETAIL 8/A7.0COUNTER BEHINDDESK, OPEN UNDER
DIFFUSER, RE: MECH
1x6 PICTURE RAILALIGN TOP W/DOOR TRIM
SOLID SURFACE TOPS(OPEN BELOW)
CONCEALEDBRACKETS
1x8 WOODBASE
AUTOMATIC DOOROPERATOR
ENCLOSURE
2'-6
"
3'-6
"
2'-3 3/8" 8 5/8"
1'-4"
SOLID SURFACECOUNTER BEYOND
BOARD WRAPBEYOND
SOLID SURFACECOUNTER
2cm EDGERETURN
CONCEALEDBRACKET TYP OF 2
A+M HARDWARE OREQUAL
RECLAIMED BOARDS,WIDTHS MAY VARY
PAINTED GYP BOARD
1x8 MAPLE BASE
1/2 PLY NAILINGSURFACE
BLOCKING
33/8" = 1'-0"
Meet& Greet
73/8" = 1'-0"
Staff Lounge 63/8" = 1'-0"
Staff Lockers
53/8" = 1'-0"
Staff Bath 43/8" = 1'-0"
Typical Bath 23/8" = 1'-0"
Meeting Room
13/8" = 1'-0"
Reception
83/4" = 1'-0"
Reception Desk Detail
1
2
1234
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A7.1Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
INTERIORELEVATIONS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
5'-0
"2'
-0"
2'-1
0"4"
PIPE GUARD,TYP
TILE UP TO TRIMBAND AT ENTRY AREA
FOLD-DOWNSHELF
BULLNOSE TRIM, TYP.
SHOWER
ENTRY/EXIT
SHOWER
PARTITIONSRE: FLOOR PLAN
4"1'
-6"
1'-6"
SOLID SURFACE COUNTERw/ INTEGRAL SINKS
24"x36" MIRROR
SOAP DISP BYOWNER
3'-0"
2'-1
1"
4"1'
-6"
2' MIN
PARTITION,RE: PLAN
TILE UP TO TRIM BANDAT CHANGING AREA
FOLDINGSHELF
BULLNOSE TRIM, TYP.
MEN'S WATER CLOSET WALL TUBLOCKER CHANGING
REMOVABLEIN-TUB SEAT
CONTROLWALL
1'-4"2'-0"11"
9"8"
17"
MAX
.
PROVIDE BLOCKINGIN WALL FOR GRABBARS, TYP
1'-6
"
1'-0" 3'-6"7'-0
"3"
1'-0" 1'-0"
2'-1
1"4"
1'-6
"
8"
1'-4
"
4'-0
"1'
-6"
PARTITIONRE: PLAN
ROBE HOOK, TYPEACH SHOWER/
CHANGING STALL
T.P. DISP.SHOWER
3'-2
"
CL
10"
24"x36" MIRROR
PIPE GUARD,TYP
ROLL-INSHOWER
CONTROLLOCATION
2'-3"
1'-6
"2'-1
1"4"
1'-6
"
2'-1
0"4"
7'-0
"3"
5" 3'-0"
2"15"-16"
SEAT
1" 2 1/2"
1'-6
"
BULLNOSETRIM, TYP.
3'-4
"1'
-6"
3'-0" 5"
PARTITION,RE: PLAN
TILE UP TO TRIM BANDAT CHANGING AREA
WOMEN'S WATER CLOSET WALLTUB LOCKER CHANGING
5" 3'-0"
2'-1
1"4"
1'-6
"
2'-1
1"
1'-0" 3'-6"
2'-1
1"
3'-4"
1'-3
"5"
1'-6
"
4'-0
" 5'-6
"
T.P. DISPENSERLOCATION
FOLDING SHELF ROBE HOOKS
8"
SHOWER
2'-1
1"4"
1'-6
"
2'-0" 4"
TILE TO TRIM BANDAT ENTRY AND LOCKER BULLNOSE TRIM, TYP.
LOCKERROOM
BEYOND
ENTER/EXIT
BEYOND
PIPE GUARD, TYP
2'-1
1"4"
2'-0
"
7'-0
"3"
4'-0
"FOLDINGSHELF
SHOWERCURTAINTRACK BYPARTITIONMFR
BATH CONTROLWALL
CONTROLLOCATIONS
CL
REMOVABLESEAT
4" BASE BYLOCKER MFR
LOCKERS
FILLER BY LOCKERMFR
SLOPED LOCKERTOP
2'-6
"6"
CONCEALED BRACKETSUPPORTS, BY A+MHARDWARE, OR EQUAL
LINE OFWALL ANGLE
LAMINATE DESKOPEN BELOW
WC4842
SB48
WC3642
F1
HALL HALL
WC4842 WC4842
LAT 33 LAT 33 LAT 33 LAT 33
3'-0
"1'
-6"
3'-6
"
F1 1
/4
F1
1/4
4" LAMINATESPLASH
LAMINATECOUNTERTOP
PTRY3084F2
ROOFACCESS
RE: PLAN
PTRY3084PTRY3684PTRY3684 F2
WALL END
FIXED STEELACCESS LADDER
3'-0
"2'
-0"
3'-0
"
3'-6
"
4"
OPENING IN BACK PANEL/WALL TO CABINET ONOPPOSITE SIDE OF WALL
REFRIGBY OWNER
(NO DOOR)
CYLINDER LOCKAT MED CABDOORS (exceptsink base)
CEILING
LAMINATECABINETS
ADJUSTABLESHELVES
OPEN BACK CABINETSIN MED ROOMS, TRIM w/ LAMINATE TOMATCH CAB INTERIOR
WC2436
SB30F 3/4" F1"
F 3/4"
LAT 33 BC24
WC2436WC3936 F1"
LAMINATEBACKSPLASH
LAMINATECOUNTERTOP
3'-0
"1'
-6"
3'-6
"
2'-5
"
LAMINATE WORKCOUNTER
CYLINDER LOCKAT CABINETDOORS (exceptsink base)
LAMINATE ENDPANEL
LAMINATE ENDPANEL
B24 SB36
WC1842 WC3342
LAMINATESPLASH
LAMINATECOUNTERTOP
MAX
34"
ACCESSIBLE SINKMAX 34" TOP OFBOWL
WINDOW TOLIVING AREA BEYOND
B36F1 B36SB39 F1
4" LAMINATESPLASH
LAMINATECOUNTERTOP
3'-0
"1'
-6"
3'-6
"SB36 DB12
WC4842
F3/4
F 3/
4
F 3/
4F3
/4
4" LAMINATESPLASH
LAMINATECOUNTERTOP7
3/8" = 1'-0"
Detox Restroom Elevations
83/8" = 1'-0"
Detox Private Bath
13/8" = 1'-0"
Nurse's Station23/8" = 1'-0"
Nurse's Station Hall
33/8" = 1'-0"
Med Room43/8" = 1'-0"
Exam Room63/8" = 1'-0"
Sleeping Area 53/8" = 1'-0"
Conf/Exam Room
12
34
12343W5
12
6
SOAP, P.T. & T.P. DISPENSERSBY OWNER, OPERABLE PARTS
MOUNTED < 48" A.F.F.
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A7.2Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
FINISH PLAN &SCHEDULE
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
F
F
F1F6
F6F4
F6
F3
F7
F3
F7
F3
F3F11
F3
F6
F3F7
F5F3
F7F14
F12
F7
F7F12
F7
F13 F7F13
F12
F11
F11
F13
F13
F14
F11F14 F3F11
F14
F13
F14F13
F14
F13
F13
F14
F14
F12
F12
F14
F12
F14
F14
F12
F11F14
F11F15
F3F11F11F14
F3
F14
F7F8
F8
F7
F7F8
F7
F8
+/-
12"
MAT
CH P
ARTI
TIO
N C
L
F5
F6
F1
F1
F6
F7
F7
F14
F9
FRP TO 8'-0" A.F.F.BEHIND MOP SINK(2 SIDES)
F5
MEN'SWAITING
BUSINESSCENTER
ADMISSION
ADMISSION
MEET + GREET
RECEPTION
MEETING ROOM
STAFFLOCKERS
PUBLICENTRY
RETAIL
WOMEN'SWAITING
HALL
HALL OFFICES
STAFFLOCKERS
WOMEN'S ENTRY
OFFICE
NURSE'SSTATION
SLEEPING AREA
LIVING
COURTYARD
BATHROOM
WOMEN'S CONF RM EXAM RM
STAFFBATH
MED
HALL
SLEEPING AREA
LIVING
COURTYARD
MEN'S
PRIVATEBATHROOM
EXAM RM
HALL
MECH/SPRINKLER
STAFF LOUNGE
AMBULANCE/STAFF/MEN'S ENTRY
IT
OFFICE
MED
MEDMED
STG
OFFICE
JAN
100
SEMI-PRIVATE
PRIVATE
SEMI-PRIVATE
SEMI-PRIVATE
SEMI-PRIVATE
PRIVATE
OFFICE
OFFICE
OFFICE
LOCKER/CHANGING
LOCKER/CHANGING
PRIVATEBATHROOM
VESTIBULE
101
102
103
122
117
116
118
119
123
126
120 121
104
105106
115
114
113
112
107
108109110111
HALL
BATH BATH
125 124127128
129VESTIBULE
133
134
162
138139
132
131
130
141
142
143
144
146
150
155
156
136157
158
135
137
140
159
161
160
CONF RM
BATHROOM
145
147
148
149
151
152
153
154
163
166VESTIBULE
165
W-5
W-5
W-6
W-6
W-6
F
F
F
F
A3.13
164
11/8" = 1'-0"
Finish Plan
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A8.0Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
DETAILS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
1-HR RATEDSMOKE BARRIER,TERMINATE ATRATED CEILING
FIRE-RATED CEILINGRE: ASSEMBLIES
FIRE BLOCKINGFIRE-RATED CEILING
RE: ASSEMBLIES
LEDGER FORTRUSS BEARING
ENGINEERED TRUSSES
RATED GYPSUM 'WALL'PROTECTION CONT. TOHIGHER RATED CEILING
VCT CEILING
ENGINEERED TRUSSES
FIRE RATED CEILING ASSEMBLY
FIRE BLOCKING
2x4 SLEEPER FOR INFILL CEILING MEMBERS
CONTINUOUS FIRE RATED CEILING
2x4 INFILL CEILING MEMBERS @ 16" O.C.5/8" GYP
TOP OF WALL BEYOND
DROPPED ACT CEILING
ENGINEERED TRUSSES
SIDE NAIL CEILING MEMBERS TO WALL STUDS
PARTITION WALLTRACK
1-HR RATEDNON-BEARINGPARTITION
FIRE-RATEDCEILING (w/ RC),RE: ASSEMBLIES
CONTINUOUS GYP.@ SOFFIT LEDGER
SOFFIT FRAMING
NON-RATEDGYP. CEILING
1x2 S4S, PAINT TOMATCH WALL COLOR
WOOD CEILING
FIRE-RATED CEILING(2 LAYERS GYP.)RE: ASSEMBLIES
FIRE BLOCKING
1A8.1
7A8.1
11 1
/4"
7 1/4"
1x WOOD WRAP'BEAM' w/MITERED CORNERS
BEAM, RE: STRUCT.
RATED CEILING,RE: ASSEMBLIES
CONTINUOUS GYP.BOARD BEHINDWOOD WRAP
LIGHT FIXTURE,RE: ELEC.
ROOF TRUSSESRE: STRUCT.
RATED EXTERIOR WALLRE: ASSEMBLIES
RATED CEILINGRE: ASSEMBLIES
EIFS EXTERIORWALL FINISH SYSTEM
ROOF TRUSSESRE: STRUCT.
SIMILAR,NO BOX SOFFIT,NO GUTTER
8A8.1
3A8.1METAL ROOF PANEL
METAL RAKE
EPDM ON BUILT-UPINSULATION ON
FLOOR SHEATHING
RATED FLOOR/CLGRE: ASSEMBLIES
DROPPED CEILINGS,
RE: RCP
METAL RAKE
STUCCO SOFFIT
EIFS WALLFINISH SYSTEM
STRUCTURALRAKE
RATED WALLRE: ASSEMBLIES,
GYP, CONTINUOUSTHROUGH DROPPED
CEILINGSRATED CEILINGON ROOF TRUSSESRE: ASSEMBLIES
METAL ROOF PANEL
STUCCO SOFFITON EAST EAVE
OVER MECH. WELL
CEMENT BOARDSTUCCO @ MECH.
WELL INTERIOR
9A8.1
3A8.1METAL ROOF PANEL
RATED EXTERIORWALL, RE: ASSEMBLIES EPDM ON BUILT-UP
INSULATION ONFLOOR SHEATHING
RATED FLOOR/CLGRE: ASSEMBLIES
METAL RAKE
STUCCO SOFFITON EAST EAVEOVER MECH. WELL
RATED SMOKEBARRIER
RE: ASSEMBLIES
RATED CEILINGON ROOF TRUSSES
RE: ASSEMBLIES
CEMENT BOARDSTUCCO @ MECH.WELL INTERIOR
9A8.1
8A8.1
RATED GYP. WRAP@ BEAM, RE: STRUCT.
WALL RATED FROMINTERIOR ONLY,RE: ASSEMBLIES
RATED FLR/CLGRE: ASSEMBLIES
EPDM ONBUILT-UP INSUL.
CEMENT BOARDSTUCCO @ MECH.
WELL INTERIOR
FIR BRECK SOFFITON N, W & S EAVESOVER MECH. WELL
STRUCTURALFASCIA
RATED CEILINGON ROOF TRUSSESRE: ASSEMBLIES
METAL ROOF PANEL
EIFS EXTERIORWALL FINISH SYSTEM
STUCCO SOFFIT
METAL FASCIA
METALROOF PANEL
SIMPSON STRAP TIE,RE: STRUCTURAL
4"
(2) 2x6 SUPPORTEDBY END WALLS
NON-RATEDGYP, WRAP
ACOUSTICCEILING TILE
CONTINUOUSRATED CEILING
CEILING SUPPORTSTRUCTUREINDEPENDENT OFRATED CEILING
METAL EDGE ANGLE
ACOUSTIC CEILING TILE
1x6 WOOD TRIM(AT MEETING ROOM ONLY)
2x4 CEILING FRAMING
LINE OF SOFFITBEYOND
5/8" GYP. CEILING, TYP.
1 1/2"
METAL ROOF
STUCCO SOFFIT
METAL RAKE
RATED CEILING
CONTINUOUSGYP
DROPPEDCEILING
CEMENT BOARDSTUCCO ATGABLE
GABLE END TRUSSw/ DROPPED TOPCHORD, SET BACK1 1/2" FROM FACE OFBEAM
TIMBER BEAM
LOG COLUMN
1x T&G SOFFIT
EIFS WALLSYSTEM
1/4 ROUNDTRIM
DRIP EDGEFLASHING
2" DROPPEDCEILING
EIFS WALLSYSTEM
EIFS WALLSYSTEM ONGABLE-ENDTRUSS
STUCCOSOFFIT
6x12 TIMBERTRIM 'BEAM',POCKET INWALL @ ENDS
STONE VENEER@ WALL BEYOND
ENTRY ROOFBEYOND
33/4" = 1'-0"
Rated Smoke Barrier43/4" = 1'-0"
Rated Ceiling 13/4" = 1'-0"
Soffit Detail23/4" = 1'-0"
Rated T&G Ceiling
53/4" = 1'-0"
Mech Well/Clerestory63/4" = 1'-0"
Mech Well/Clerestory73/4" = 1'-0"
Mech Well/Clerestory83/4" = 1'-0"
Mech Well/Clerestory
101 1/2"= 1'-0"
Wrapped Clg Transition 91 1/2"= 1'-0"
Interior Soffit Detail113/4" = 1'-0"
N. Entry Detail123/4" = 1'-0"
East Entry Soffit
RE: 1/A4.3 RE: 1/A4.1RE: 3/A4.1RE: 3/A4.1
bas1s.com
Este
s Pa
rk, C
olor
ado
8051
716
92 B
ig T
hom
pson
Ave
nue,
Sui
te 1
00
A8.1Sheet No:
fax: 970.586.9149vox: 970.586.9140
Sheet Title:Sheet Title:
Date:
A R C H I T E C T U R E P. C.
Architecture, P.C.
Issue:
© BASIS
DETAILS
Har
mon
y Fo
unda
tion
Inc
Adm
issi
ons/
Det
ox16
00 F
ish
Hat
cher
y R
oad
Est
es P
ark,
Col
orad
o 80
517
Construction
3/28/2014
CONTINUOUSRATED CEILING
2x BULKHEADFRAMING
(2) W12x35STEEL BEAMS
(2) LAYERSGYP. BOARD
RECESSED CAN,RE: ELECTRICAL
CEILING UPLIGHT,RE: ELECTRICAL
SUPPLY DUCT,RE: MECHANICAL
WALL GRILLE,RE: MECHANICAL
NAILERS
MOVABLE PARTITIONS
ALL THREADANCHORSOR EQUAL
ACOUSTIC INSUL.
2"
1" 1"
4"
WOOD HAND RAIL
HIGH-IMPACT VINYLACRYLIC COVER
VINYL ACCENT STRIP
MOUNTING BRACKET
CONTINUOUS ALUMINUMRETAINER
ROOF SHEATHING
ROOF UNDERLAYMENT
METAL 'Z', CAULK TOROOF PANEL @
BOTTOM EDGE AND @ALL VERT. ROOF SEAMS
METAL ROOF PANEL
METAL FLASHINGMETAL DRIP EDGE
FLEXIBLE FLASHING
STUCCO FINISHSYSTEM
MIN
14"
N.T
.S.
DRIP EDGE FLASHING
FLEXIBLE FLASHING
CEMENT BOARDSTUCCO FINISHSYSTEM
BUILT-UP INSULATION
EPDM MEMBRANE
TERMINATION BARSEALANT
ROOF SHEATHING
ROOF UNDERLAYMENT
METAL 'Z', CAULK TOROOF PANEL @
BOTTOM EDGE AND @ALL VERT. ROOF SEAMS
METAL ROOF PANEL
CLEAT
CONTINUOUS METALSTRIP FLASHING
ROOF VENT,RE: SPEC.
METAL ROOF CAP
SOFFIT VENT,RE: SPEC.
STUCCO SOFFIT, TYP.
METAL FASCIA& GUTTER
METAL PANEL ROOF
TIMBER BEAMRE: STRUCT.
METAL GUTTER
FLEXIBLE FLASHINGDRIP FLASHING
ROOF UNDERLAYMENTMETAL ROOF PANEL
G
R
METAL GUTTER
FLEXIBLE FLASHING
METAL FASCIA
GUTTER ATTACHMENT2x SUB FASCIA
ROOF UNDERLAYMENT
METAL ROOF PANEL
STUCCO SOFFIT
STRIP SOFFITVENT
SEALANT
RAFTER, RE: STRUCT.2x T&G DECKING
ROLL ROOF PANEL EDGEFLEXIBLE FLASHING
DRIP EDGE
ROOF UNDERLAYMENTMETAL ROOF PANEL
ROLL ROOF PANEL EDGE
METAL RAKE
FLEXIBLE FLASHING2x SUB RAKE
ROOF UNDERLAYMENT
METAL ROOF PANEL
STUCCO SOFFIT
ROOF UNDERLAYMENT
METAL ROOF PANEL,FLASH UP WALL
METAL DRIP EDGE
FLEXIBLE FLASHING
STUCCO FINISHSYSTEM
1/4"
1x WOOD CAP
SHIM AS REQ'D
PTD GYP BOARD
103/4" = 1'-0"
Movable Partition Detail
116" = 1'-0"
Handrail Detail
71 1/2"= 1'-0"
Wall to Roof
91 1/2"= 1'-0"
Wall to Mech Roof 61 1/2"= 1'-0"
Typical Ridge
21 1/2"= 1'-0"
Rake Soffit
41 1/2"= 1'-0"
Entry Eave 11 1/2"= 1'-0"
Typcal Eave
51 1/2"= 1'-0"
Entry Rake
31 1/2"= 1'-0"
Typical Rake
81 1/2"= 1'-0"
Wall to Roof
121 1/2"= 1'-0"
Wall Cap Detail