84
GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER-FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

GEZE SWING DOOR SYSTEMSCLEVER SYSTEMS. FOR BARRIER-FREE ACCESS.

G E Z E AU TO M AT I C D O O R S YS T E M S

BE WEGUNG MIT SYSTEM

Page 2: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Cover photo and photo on page 2: GEZE GmbH

Page 3: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

3

Automatic swing door systems

ECturn, SLIMDRIVE EMD, TSA 160 NT AND POWERTURN

Swing door systems

Foreword: GEZE swing door systems 4

Overview table 5

Types of installation 6

Automatic swing door systems

For fire and smoke protection doors (F) 7

With integrated closing sequence control (IS) 7

With integrated closing sequence control for double-leaf fire and smoke protection doors (F-IS) 8

With integrated closing sequence control for double-leaf doors, automatic doors and door closer function (IS/TS) 8

For fresh air supply as well as doors in emergency exits (Invers) 9

For large and heavy doors, as well as frequently used doors (EN7) 9

Special area of application: Accessible toilet 10

Swing door drives

GEZE ECturn 11

GEZE ECturn Inside 23

GEZE Slimdrive EMD 28

GEZE TSA 160 NT 42

GEZE Powerturn 54

Accessories (Cover, mounting plate, link arm, roller guide rail with lever) 69

Operation 70

Activation 71

Protection 73

Service Tools 79

References 80

TABLE OF CONTENTS

Page 4: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

GEZE swing door systems

Open and close doors easily

The automatic swing door systems from GEZE make passing through a door easier every time when manual opening is too hard or inconve-nient. They are recommended in public as well as in private buildings, when convenience, accessibility, safety and hygiene are necessary or when energy has to be saved: in shopping centres, schools, office or industrial buildings, airports, hospitals, vestibules or in individual homes.

ECturnThe ECturn electromechanical swing door drive is recommended for single-leaf smaller internal and entrance doors of up to 125 kilogram with moderate access frequency. ECturn is so small and discreet that even frameless all-glass doors can be automated. In addition, ECturn Inside enables an “invisible” door automation. Thanks to its small dimensions, it can be integrated in the door leaf or in the frame. ECturn Inside was labelled with the Interior Innovation Award by the German Design Council.

Slimdrive EMDThe Slimdrive EMD electromechanical swing door drive is suitable for single and double-leaf doors of up to 230 kilogram, slim profiles and small spaces. Slimdrive EMD, with a drive height of only seven centimetres, various cover designs and adjustment options, fits in every door situation and is also approved in fire protection doors. It was already labelled with two Plus X Awards.

TSA 160 NTThe TSA 160 NT approved electrohydraulic swing door drive opens and closes doors of up to 250 kilogram safely and reliably. It manages high public access easily. Multiple variations enable various applications.

PowerturnThe Powerturn electromechanical swing door drive provides a high function and design variety. The robust, efficient drive opens single and double-leaf large and heavy doors with leaf weights of up to 600 kilogram quietly and reliably. With its 7-cm-optics, it fits in every door design. Thanks to the Smart swing function, even manual door-opening is child‘s play. Hence Powerturn is a prime example for Universal Design.

Design possibilities for swing door systemsDIN 18650 The industrial standard DIN 18650 was created to be able to gu-arantee operators and users of automatic doors optimum safety. GEZE swing door systems with automatic function have been type-tested to DIN 18650 and certified.

EN 16005The new European standard EN 16005 sets out the de-sign requirements and testing methods used to ensure the safe use of automatic doors. The new standard has cre-ated a Europe-wide safety standard for automatic doors. All automatic door systems and safety sensors from GEZE meet the EN 16005 standard and are available.

DIN 18040DIN 18040 formulates the safety objectives for publicly accessible buildings and apartments and shows the requirements of people with sensory and cognitive limitations. The automatic swing door systems of GEZE are attractive not only for people with limited mobility. Accessibility is also reflected in the concept of Univer-sal Design and in the topical subject “Inclusion”. According to this concept, buildings must be made easy to access for the largest possible group of people, and it must be possible to use them without help.1 = Drive

2 = Radar movement detector3 = Plastic elbow switch4 = Programme switch 5 = Proximity switch6 = Elbow switch7 = Glass LED sensor button8 = Interruption button9 = Foot contact switch10 = Sensor strip

4

Automatic swing door systems

ECturn, SLIMDRIVE EMD, TSA 160 NT AND POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Page 5: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

5

Automatic swing door systems

ECturn, SLIMDRIVE EMD, TSA 160 NT AND POWERTURN

Swing door systems

ECturn Slimdrive EMD TSA 160 NT Powerturn

Product features

Dimensions drive (height x width x depth) 60x580x60 mm 70x650x121 mm 100x690x121 mm 70×720×130 mm

Leaf weight (max.) 125 kg180 kg

230 kg*250 kg 600 kg

Leaf width (min.)GLS / RS1

650 mm850 mm

690 mm 800 mmGST 750 mm

Leaf width (max.)GLS / RS1

1100 mm 1400 mm 1400 mm 1600 mmGST

Hinge clearance on double-leaf doorsGLS / RS1 – 1700-2500 mm

1470-2800 mm 1600 – 3200 mmGST – 1500-2800 mm

Opening and closing speed adjustable ● ● ● ●

Electrical closing sequence control ● ● ●

Electromechanical drive ● ● ●

Electrohydraulic drive ●

External doors / Internal doors – / ● ● / ● ● / ● ● / ●

Integrated in door leaf or in door frame ●**

1-leaf / 2-leaf ● / – ● / ● ● / ● ● / ●

Guide rail / Roller guide rail / Link arm ● / - / ● - / ● / ● - / ● / ● - / ● / ●

Functions

Automatic ● ● ● ●

Push & Go adjustable ● ● ● ●

Low-Energy ● ● ●

Smart swing ●

Servo ● ●

Variants

For fire and smoke protection doors (F) ●* / **** ● ●

With integrated smoke switch (F/R) ●* / **** ●

With integrated closing sequence control (IS) ●* ● ●

With integrated closing sequence control for double-leaf fire and smoke protection doors (F-IS)

●* / **** ● ●

With integrated closing sequence control for double-leaf doors, automatic doors and door closer function (IS/TS)

● ●

For fresh air supply as well as doors in emergency exits (Invers) ● ●

For large and heavy doors, as well as frequently used doors (EN7) ●

Page 11 28 42 54

RS = Roller guide railGLS = Guide railGST = Link arm ● = Yes 1 = GLS: ECturn / RS: Slimdrive, TSA and Powerturn * = Slimdrive EMD-F ** = ECturn Inside **** = Types of installation: transom installation hinge side with roller guide rail / transom installation opposite hinge side with link arm

Note: The maximum possible leaf weight in relation to leaf width can be found in the chapter on areas of application (diagrams)!

Overview table for swing door systems

Page 6: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Types of installation for swing door systems

The following diagrams show the installation possibilities for swing doors and the drives which can be used to realise this application.

NotesA door stopper is always required.We recommend link arms for external doors. Wind loads and underpressure or excess pressure must also be taken into account.

Installation on the hinge side

Transom installation with guide rail / roller guide rail

1 = ECturn2 = Slimdrive EMD3 = TSA 160 NT4 = Powerturn

Door leaf installation with guide rail / roller guide rail

1 = ECturn2 = Slimdrive EMD3 = Powerturn

Door leaf installation with link arm

1 = ECturn2 = Powerturn

Installation on the opposite hinge side

Transom installation with link arm

1 = ECturn2 = Slimdrive EMD3 = TSA 160 NT4 = Powerturn

Transom installation with guide rail / roller guide rail

1 = ECturn2 = Slimdrive EMD3 = Powerturn

Door leaf installation with guide rail / roller guide rail

1 = ECturn2 = Powerturn

Installation in the door leaf / installation in the door frame

1 = ECturn Inside

6

Automatic swing door systems

ECturn, SLIMDRIVE EMD, TSA 160 NT AND POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Page 7: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Swing door systems for fire and smoke protection doors (F)

Drive systems in the F variant are used to automatically open and close 1-leaf fire protection doors. The usual types of impulse generator can be used to actuate the drive. In addition to automatic opening and closing, fire protection doors can also be held open. In the event of a fire, an appropriate fire detection system must cancel the automatic function or any hold-open mechanism. The power supply to the mains cable is interrupted via a mains switch-off board (F-accessory) and the drive retains the normal door closer performance. This means that door closers with automatic opening function in accordance with DIN 18263 Part 4 are a component part of hold-open systems and require official buil-ding approval. Fire protection doors must meet the requirements of the DIBt guideline (Deutsches Institut für Bautechnik). Powerturn F and Slimdrive EMD-F as well as both variants with integrated smoke switch fulfil the highest design requirements.This variant can be realised using the following drive series: Slimdrive EMD-F, TSA 160 NT and Powerturn

Swing door systems with integrated closing sequence control (IS)

Swing door systems in the IS variant are always equipped with an integrated closing sequence control (electronic or mechanical). The closing sequence control ensures that the fixed leaf closes first on 2-leaf doors. The active leaf only closes once the fixed leaf has closed completely. The mechanical closing sequence control also works without electricity and in the event of a power failure.This variant can be realised using the following drive series: Slimdrive EMD-F, TSA 160 NT and Powerturn

F swing door

IS swing Door

Photo: Jürgen Pollak

Hospital, Düsseldorf, Germany (Photo: Lothar Wels)

7

Automatic swing door systems

ECturn, SLIMDRIVE EMD, TSA 160 NT AND POWERTURN

Swing door systems

Page 8: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Swing door systems with integrated closing sequence control for double-leaf fire and smoke protection doors (F-IS)

Drive systems in the F-IS variant are used to automatically open and close double-leaf fire protection doors. A mechanical closing sequence control is necessary for double-leaf fire protection doors, refer to the section on integrated closing sequence control (IS). This variant can be realised using the following drive series: Slimdrive EMD-F, TSA 160 NT and Powerturn

Swing door systems with integrated closing sequence control for double-leaf doors, automatic doors and door closer function (IS/TS)

With this variant for double-leaf swing door systems, the active leaf is automated with a swing door drive and the fixed leaf is equipped with a door closer. Since the drive design is not interrupted, this system produces harmonious results, both in terms of function and appearance. The preferred use for this swing door drive/door closer combination is when the active leaf is the one mainly moved. The closing sequence control required for use on fire protection doors is also integrated in the drive housing. The Powerturn F/R-IS/TS version for hold-open systems combines innovative technology and design since the smoke control unit is invisibly integrated into the cover.This variant can be realised using the following drive series: TSA 160 NT IS/TS and Powerturn IS/TS

F-IS swing door

F-IS/TS swing door

Hospital, Düsseldorf, Germany (Photo: Lothar Wels)

Danish Association for Disabled, Taastrup, Denmark (Photo: Morten Bak)

8

Automatic swing door systems

ECturn, SLIMDRIVE EMD, TSA 160 NT AND POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Page 9: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Swing door systems for fresh air as well as doors in emergency exits (Invers)

Inversely installed swing door drives are used on single and double-leaf single-action doors made of wood, plastic or steel. There is an electrical closing sequence control available for double-leaf doors. Inversely installed drives are suitable for emergency exits and for fresh air opening systems for RWA systems. The doors are opened by spring force and closed by motor. This guarantees that the door will open safely in the event of a power failure or fire alarm. An emergency power supply is no longer required.This variant can be realised using the following drive series: Slimdrive EMD and TSA 160 NT

Inverse swing door

Augustinum retirement home, Stuttgart, Germany (Photo: Dirk Wilhelmy)

Swing door systems for large and heavy doors, as well as frequently used doors (EN7)

GEZE swing door drives can be used for the safe and reliable automatic operation of even very large and heavy swing doors with leaf weights of up to 600 kg. The F-version of the drive variants with a closing force size EN7 are suitable and approved for fire protection doors with leaf weights up to 600 kg or with a leaf width of 1600 mm. Optimum areas of application are facilities for the elderly, hospitals, shopping centres, schools or airports.The closing force size EN7 can be realised with the following drive series: Powerturn

Powerturn swing door

Photo: GEZE GmbH

9

Automatic swing door systems

ECturn, SLIMDRIVE EMD, TSA 160 NT AND POWERTURN

Swing door systems

Page 10: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Special area of application: accessible toilet

Accessible toilets must be designed in such a way that people with all sorts of different handicaps can use the facilities without needing help. GEZE swing door drives provide an indispensable service for this application, and guarantee a high level of convenience.

Description of functionThe door opens automatically after the elbow switch on the outside of the toilet has been pressed, and closes automatically after the set hold-open time has passed. When the push button is activated inside the toilet cabin, the system is switched to the exit only mode of operation, which means the outer push button can no longer open the door. The lights are also activated, indicating that the toilet is occupied. The electric strike supplied with current prevents manual opening of the door from outside. Pressing the internal push button again switches the mode of operation back to automatic. The OCCUPIED signs are switched off, the door opens and the external push button is cleared again. When the door is closed and locked, and manual passing from inside to outside is recognised, the WC control function is disrupted. The toilet can then be used via the outside push button.

A WC alarm can be triggered via an additional external signal transmitter (horn/light) if the system is locked for longer than 30 minutes.

In the event of a power failure, the electric strike (fail-safe electric strike) releases and the user can leave the cubicle by pushing or pulling the door open. In emergencies, the door can be opened manually from the outside by means of a key, or by triggering the emergency shut-off switch.

1

2

3

4

5

3

4

6

1 = Swing door drive 2 = Isolator (recommended installation height: 1600 mm)3 = „Occupied“ indicator light4 = Elbow switch OPEN DOOR (inside and outside)5 = Emergency pull cord6 = Sensor strip

10

Automatic swing door systems

SLIIMDRIVE EMD AND POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Page 11: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

GEZE ECturn swing door drive

Electromechanical swing door drive for 1-leaf single-action doors as „entry door solution“ (including all-glass doors)

This extremely quiet electromechanical swing door drive meets the requirements of barrier-free building. It makes life easier and more con-venient – particularly for people with mobility problems or little strength. Doors can comfortably be opened automatically or manually and closed automatically. GEZE ECturn can be operated both in low-energy mode and in automatic mode in accordance with DIN 18650 / EN 16005. In low-energy mode, the drive moves the swing door at reduced speed. The use of safety sensors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing area of the door must always be safeguarded with safety sensors. An optional rechargeable battery ensures maximum safety even in the event of a power failure. This swing door drive covers all internal application cases. Thanks to the glass guide rail available as an accessory, ECturn can also be used on glass doors (glass thickness 8-10 mm). ECturn is very flexible and permits all hinge variants, both for DIN left and DIN right doors.

GEZE ECturn

60

60

94

5

max. 277

20,7

442 (512)

5805 60

6094

,5

31

Application range • Barrier-free entrance doors and internal doors • All-glass doors • Hotels and gastronomy • Hospitals and nursing homes for the elderly • Educational institutions, e.g. schools, nursery schools, day care centres • Leisure facilities, e.g. baths, thermal baths, sport and wellness centres • Administration and public buildings • Homes

11

Automatic swing door systems

GEZE ECturn

Swing door systems

Page 12: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Technical data

Product features GEZE ECturnHeight 60 mmWidth 580 mmDepth 60 mmLeaf weight (max.) 1-leaf 125 kgLeaf width (min.-max.) 650 – 1100 mmReveal depth (max.)* 200 mmDoor overlap (max.)* 50 mmDrive type ElectromechanicalDoor opening angle (max.)* 110 °DIN left ●DIN right ●Transom installation opposite hinge side with link arm ●Transom installation opposite hinge side with guide rail ●Transom installation hinge side with guide rail ●Transom installation opposite hinge side with guide rail on all-glass doors ●Transom installation hinge side with guide rail on all-glass doors ●Door leaf installation opposite hinge side with guide rail ●Door leaf installation hinge side with guide rail ●Door leaf installation hinge side with link arm ●Electrical latching action ●Disconnection from mains Main switch in the driveActivation delay (max.) 10 SOperating voltage 110 - 230 VFrequency of supply voltage 50 – 60 HzCapacity rating 75 WPower supply for external consumers (24 V DC) 600 mATemperature range** -15 – 50 °CIP rating IP20Operating modes Off, Automatic, Permanently open, NightType of function Fully automaticAutomatic function ●Low-energy function ●Key function ●Obstacle detection ●Automatic reversing ●Push & Go adjustableOperation Keypad programme switch TPS,

Programme switch integrated in the driveParameter setting Display programme switch DPS, ControlApprovals DIN 18650, EN 16005● = Yes* = Depending on the type of installation** = The door drive is intended for use in dry rooms only

NOTE: THE MAXIMUM POSSIBLE LEAF WEIGHT IN RELATION TO LEAF WIDTH CAN BE FOUND IN THE CHAPTER ON AREAS OF APPLICATION (DIAGRAMS)!

12

Automatic swing door systems

GEZE ECturn

GEZE AUTOMATIC DOOR SYSTEMS

Page 13: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Areas of application

NoteIn low-energy mode the drive moves the swing door at reduced speed, thus fulfilling the safety requirement in DIN 18650 / EN 16005. The use of safety sensors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing area of the door must always be safeguarded with safety sensors.

X = Door width (mm)Y = Door weight (kg)1 = Area of application in low-energy mode2 = Area of application in automatic mode

GEZE ECturn (Photo: Studio BE)

0

20

40

60

80

100

120

140

600 700 800 900 1000 1100 X

Y

2

1

13

Automatic swing door systems

GEZE ECturn

Swing door systems

Page 14: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Installation with mounting plate (A) and direct installation (B)

575415390,5

302142

78

120 428,5

ø16

633390,5

266

13178

ø16

120 428,5

1

2

3

1

2

3

A B

A = Installation with mounting plateB = Direct installation1 = Concealed cable routing for low-voltage connection and mains cable2 = Dimensional reference centre of hinge3 = Concealed cable routing for low-voltage connection

Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).

Transom installation with guide rail on the hinge side, single-leafDrawing no. 70107-ep01 Reveal depth (max.) 40 mmDoor overlap (max.) 40 mm

* = Direct installation1 = Space needed for ECturn2 = Space needed for guide rail3 = Space needed for sensor strips

74

3342

1616

10

59

5 60

21

70

44*

1

2

3

32*

14

Automatic swing door systems

GEZE ECturn

GEZE AUTOMATIC DOOR SYSTEMS

Page 15: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Installation with mounting plate (A) and direct installation (B)

575415390,5

302142

78

498,5 70

ø16

633390,5

266131

78

70498,5 ø1

6

A B

1

2

3

ø16

1

2

3

A = Installation with mounting plateB = Direct installation1 = Concealed cable routing for low-voltage connection2 = Concealed cable routing for low-voltage connection and mains cable3 = Dimensional reference centre of hinge

Transom installation with guide rail on the opposite hinge side, single-leafDrawing no. 70107-ep02 Reveal depth (max.) 30 mm

* = Direct installation1 = Space needed for ECturn2 = Space needed for guide rail3 = Space needed for sensor strips

605

60

72

3342

1616

10

35

84

44*

30*

1

2

3

15

Automatic swing door systems

GEZE ECturn

Swing door systems

Page 16: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Transom installation with link arm on the opposite hinge side, single-leaf Drawing no. 70107-ep03 Reveal depth (max.) 200 mm

* = Direct installation1 = Space needed for ECturn2 = Space needed for link arm3 = Space needed for sensor strips

Installation with mounting plate (A) and direct installation (B)

ø16

78

575415

390,5302

142

28742,5

633390,5

266131

78

ø16

42,5 287

1

2

3

1

2

3

A B

A = Installation with mounting plateB = Direct installation1 = Concealed cable routing for low-voltage connection2 = Concealed cable routing for low-voltage connection and mains cable3 = Dimensional reference centre of hinge

5 60

110

34

60

35 26

99

42

1616

44*

1

2

3

34*

16

Automatic swing door systems

GEZE ECturn

GEZE AUTOMATIC DOOR SYSTEMS

Page 17: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Door leaf installation with guide rail on the hinge side, single-leaf Drawing no. 70107-ep04 Door overlap (max.) 50 mm

* = Direct installation1 = Space needed for guide rail2 = Space needed for ECturn3 = Space needed for sensor strips

Installation with mounting plate (A) and direct installation (B)

ø16

120 428,5

78

142

302

390,5

415

575

120 428,5

78

131

266

390,5

633

ø16

1

2

3 3

2

1

A B

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for low-voltage connection and mains cable3 = Concealed cable routing for low-voltage connection

99

42

2416

16

33

5

60

3560 11

0

44*

32*

1

2

3

17

Automatic swing door systems

GEZE ECturn

Swing door systems

Page 18: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Door leaf installation with link arm on the hinge side, single-leaf Drawing no. 70107-ep06Door overlap (max.) 200 mm

* = Direct installation1 = Space needed for link arm2 = Space needed for ECturn3 = Space needed for sensor strips

Installation with mounting plate (A) and direct installation (B)

287 42,5

ø16

78

142

302390,5415

575

ø16

287 42,5

633

390,5

266

131

78

A B

1

2

3

1

2

3

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for low-voltage connection and mains cable3 = Concealed cable routing for low-voltage connection

5 60

110

34

60

35 26

99

42

1616

44*

1

2

3

34*

18

Automatic swing door systems

GEZE ECturn

GEZE AUTOMATIC DOOR SYSTEMS

Page 19: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Door leaf installation with guide rail on the opposite hinge side, single-leaf Drawing no. 70107-ep05 Reveal depth (max.) 20 mm

* = Direct installation1 = Space needed for guide rail2 = Space needed for ECturn3 = Space needed for sensor strips

Installation with mounting plate (A) and direct installation (B)

100498,5

ø16

58122

282370,5395

555

498,5 100

111

58

246

370,5613

ø16

A B

1 2

3

1 2

3

A = Installation with mounting plateB = Direct installation1 = Concealed cable routing for low-voltage connection2 = Dimensional reference centre of hinge3 = Concealed cable routing for low-voltage connection and mains cable

3342

1616

5 60

35

11099

60

1

23

44*

32*

19

Automatic swing door systems

GEZE ECturn

Swing door systems

Page 20: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Transom installation with glass guide rail on the hinge sideDrawing no. 70107-ep09

* = Direct installation1 = Space needed for ECturn

Installation with mounting plate (A) and direct installation (B)

A = Installation with mounting plateB = Direct installation1 = Concealed cable routing for low-voltage connection2 = Concealed cable routing for low-voltage connection and mains cable3 = Dimensional reference centre of hinge

A B

ø 16

ø 16

ø 16 ø 16

1230

78

390.5

142

575

415

302

1428

131

633

266

78

390.5

2 2

3 3

1

1

8-10

1

12

72

1616

50

21

60max. 35 5

105

2120*

4244*

20

Automatic swing door systems

GEZE ECturn

GEZE AUTOMATIC DOOR SYSTEMS

Page 21: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Transom installation with glass guide rail on the opposite hinge sideDrawing no. 70107-ep19

* = Direct installation1 = Space needed for ECturnLT = Soffit depth

Installation with mounting plate (A) and direct installation (B)

A = Installation with mounting plateB = Direct installation1 = Concealed cable routing for low-voltage connection2 = Concealed cable routing for low-voltage connection and mains cable3 = Dimensional reference centre of hinge

A B

ø 16ø 16

22

3 3

11

130

142

575

415

302

78

390.5

328

78

390.5

131

633

266

1

9

45

109*8

61

508- 10

21

1616

5LT=max.40min.15

5

60

42

44*

21

Automatic swing door systems

GEZE ECturn

Swing door systems

Page 22: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Legend for the cable plans

Cables1 = NYM-J 3 x 1.5 mm2

2 = J-Y(ST)Y 1 x 2 x 0.6 LG3 = J-Y(ST)Y 2 x 2 x 0.6 LG4 = J-Y(ST)Y 4 x 2 x 0.6 LG5 = LiYY 2 x 0.25 mm2

6 = LiYY 4 x 0.25 mm2

7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2

8 = Route empty pipe with pull-wire inner diameter 10 mm

Notes • Cable plans can also be prepared for specific building projects after receipt of order • Version of standard cable plans in accordance with GEZE specifications • Cable routing according to VDE0100/ IEE regulations • Allow the cable for the drive to project at least 1500 mm out of the wall

1) Door transmission cable (included in the scope of supply for sensor strip)2) Cable exit for door drive, see installation drawings for ECturn 70107-ep01 to -ep063) Cable included in the scope of supply for the sensor4) + 5) Connection box for mains supply and control cable combined on site. Mains supply and control cable must be wired in separate terminal spaces.4) Mains connection box WxHxD min. 65 x 65 x 575) Control cable box WxHxD min. 94 x 65 x 57 with PG-11 duct

I = Feeder 230 V / 50 HzII = 10 A fuseIII = Connected load 230 W 1 AIV = And / OrV = Option

B+200

B/2

B

B/2

KI

KAECturn

max. 100

max

. 300

4)

5)

1-leaf

I = Transom installation concealed cable routingII = Door leaf installation

AbbreviationsHS = Main switchNOT = Emergency-stop switchKB = Contact sensor authorisedPS = Programme switchST = Emergency stopKI = Contact sensor insideKA = Contact sensor outsideTOE = Door openerRM = Bar message

7

88

A

B

A

B 5)

4)

RMTOE

12)

1)

8

RMTOE

2)

GC 338 GC 338

ECturnECturn

I II

3)3)KA

388

31 11 1

KB

3

KI

3

ST

3

PS

B

A

HS NOT

I

II

III

IV

VV

22

Automatic swing door systems

GEZE ECturn

GEZE AUTOMATIC DOOR SYSTEMS

Page 23: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

GEZE ECturn Inside swing door drive

Electromechanical swing door drive for 1-leaf single-action doors as „entry door solution“ and inside

With the ECturn Inside swing door drive, GEZE combines accessibility and safety with optimum door design. Thanks to its small dimensions, the drive can be integrated into the door leaf of internal doors (min. thickness 55 mm). ECturn Inside opens and closes doors “invisibly” without compromising their appearance. The wide range of special functions such as radio push buttons, mobile radio remote control units or acoustic signals allow the system to be tailored to specific user requirements. ECturn Inside can be operated in low-energy and automatic modes. In low-energy mode the drive moves the swing door at reduced speed, thus fulfilling the safety level of DIN 18650 and EN 16005. An optional rechargeable battery provides a safeguard in the event of a power failure ensuring that the door continues to open automatically and safely. The door can also be opened manually in the event of a power failure.

GEZE ECturn InsideDrawing shows installation in wooden door leaf, door frame is reversed (mirror-image)

GEZE ECturn InsideDrawing shows installation in metal door leaf, door frame is reversed (mirror-image)

Application range • Barrier-free entrance doors and internal doors • Hotels and gastronomy • Hospitals and nursing homes for the elderly • Educational institutions, e.g. schools, nursery schools, day care centres • Leisure facilities, e.g. baths, thermal baths, sport and wellness centres • Administration and public buildings • Homes

12.5*20

45

16

66.5

16

87

608.5

65

491

16

47384

302.5285

84

11

45

2012.5*

566306

61 61

12

457

(69)

(5.4

)

11

77

77

23

Automatic swing door systems

GEZE ECturn Inside

Swing door systems

Page 24: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

X = Door width (mm)Y = Door weight (kg)1 = Area of application in low-energy mode2 = Area of application in automatic mode

Technical data

Product features GEZE ECturn InsideHeight 61 mmWidth 566 mmDepth 45 mmLeaf weight (max.) 1-leaf 125 kgLeaf width (min.-max.) 700 – 1100 mmDrive type ElectromechanicalDoor opening angle (max.)* 110 °DIN left ●DIN right ●Installation in the door leaf ●Installation in the door frame ●Electrical latching action ●Activation delay (max.) 10 SSupply voltage Power supply: 110 - 230 VOperating voltage Drive: 24.5 - 30 V DCCapacity rating 75 WPower supply for external consumers (24 V DC) 600 mATemperature range -15 – 50 °CIP rating IP20Operating modes Off, Automatic, Permanently open, NightType of function Fully automaticAutomatic function ●Low-energy function ●Key function ●Obstacle detection ●Automatic reversing ●Push & Go adjustableOperation Programme switch integrated in the drive, Keypad programme switch TPSParameter setting Control, Display programme switch DPSApprovals DIN 18650, EN 16005● = Yes* = Depending on the type of installationNOTE: THE MAXIMUM POSSIBLE LEAF WEIGHT IN RELATION TO LEAF WIDTH CAN BE FOUND IN THE CHAPTER ON AREAS OF APPLICATION (DIAGRAMS)!

Areas of application

NoteIn low-energy mode the drive moves the swing door at reduced speed, thus fulfilling the safety requirement in DIN 18650 / EN 16005. The use of safety sensors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing area of the door must always be safeguarded with safety sensors.

0

20

40

60

80

100

120

140

600 700 800 900 1000 1100 X

Y

2

1

24

Automatic swing door systems

GEZE ECturn Inside

GEZE AUTOMATIC DOOR SYSTEMS

Page 25: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Overview of components

1 = Cover for the motor drive control2 = Back check3 = Guide rail and lever4 = Separate programme switch (optional)5 = Fixture for rechargeable battery (optional)6 = Rechargeable battery (optional)7 = Control

Installation in the wooden door frameDrawing no. 70107-ep10

A = Frame cut-outB = Door cut-out1 = Recess for programme switch (optional)2 = Recess for lever* = Dimensions or positions can deviate depending on the door type.

8 = Motor drive control9 = Supply cable, inside door 2.5 m10 = Electric installation material11 = Cable transition (optional)12 = Supply cable (on site)13 = Power supply (flush-mounted)

Z

3

20

R8.5 Z

458

19.5*

113

12

113

46

566 6.5*

(61.

5)

R10 R1027

14

38*

69.5

13.5

*

591*

6.5*

(832)

13

67.5

2

1

Ø

A B

25

Automatic swing door systems

GEZE ECturn Inside

Swing door systems

Page 26: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Installation in the wooden door frameDrawing no. 70107-ep13

A = Cut-out for driveB = Door cut-out1 = Cut-out for lever* = Dimensions or positions can deviate depending on the door type.

Installation in the metal door leafDrawing no. 70107-ep12

A = Frame cut-outB = Door leaf cut-out1 = Cut-out for programme switch (optional)* = Dimensions or positions can deviate depending on the door type.

Installation in the metal door frameDrawing no. 70107-ep14

A = Frame cut-outB = Door cut-out* = Dimensions or positions can deviate depending on the door type.

A B

1

61*

113 566

46 7*

R10

Z

3

20

R8.5

Z

61.5

*

458 20*113

564 *

5*

18.5

*

A B

Z9

20

5

R 7.53.5Z

115 455

473

75*

27.5

*

Y

830 46

10

R 5

3.5(6x)

Y

8

10.5133.5

265

20

282

285

30

4646 21123.5

(75)

(839)

302.5

22

65.4

ØØ

1

A B

Z

830 46 R 5

3.5(6x)

Z

830

133.5

10.5

46 21

302.5

20

285123.5282265

(75)46

Y

205

9

R7.5 3.5(2x)Y

473

115 455

(75)

(839)

27.5

*

Ø

Ø

26

Automatic swing door systems

GEZE ECturn Inside

GEZE AUTOMATIC DOOR SYSTEMS

Page 27: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Notes • This cable plan is a simplified symbolic illustration. Connections must be taken from the wiring diagram. Cable routing is included in

the VDE guidelines. • Positioning of the activation and operating devices must be specified on site • Positions shown with dotted lines are positioned on the opposite side • In compliance with DIN 18650 / EN 16005 for automatic mode sensor strips on both sides

Legend for the cable plan1 = NN YM-J 3x1.5 mm²2 = JJ-Y(ST) Y 2x2x0.6 mm²10 = Empty pipe Ø 10 mm with pull-wire; cable supplied by GEZE, max. 3 m11 = Cable information must be provided on site

13 = J-Y(ST) Y 2x2x0,6 mm²; optional empty pipe Ø 10 mm with pull-wire16 = Empty pipe Ø 10 mm with pull-wire; J-Y(ST)Y 4x0.6mm LG17 = Empty pipe Ø 12 mm with pull-wire; NYM-O 2x1.5mm218 = Cable supplied by GEZE, cable length max. 3 mi = Cable consolidation for control/activation devices (symbolic)RSK = Lock switch contact

Entry door, private home, Stuttgart, Germany (Photo: GEZE GmbH)

Standard cable plan maximum coverage, pulling on one side, 1-leaf, DIN right

27

Automatic swing door systems

GEZE ECturn Inside

Swing door systems

Page 28: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

GEZE Slimdrive EMD swing door drive

Electromechanical swing door drive for 1 and 2-leaf single-action doors

The GEZE Slimdrive EMD electromechanical swing door drive stands out due to its numerous areas of application. The compact drive is only 7 cm high and can move large and heavy internal and external doors comfortably and quietly. This makes Slimdrive EMD the ideal solution wherever efficiency has to be coupled with silent running. State-of-the-art control technology combined with a low-wear and maintenance-free high-power motor guarantees reliable operation even for doors which are heavily frequented. All door parameters e.g. opening and closing speed as well as latching action, can be optimally adapted. Manual door opening can be supported by the drive (servo function) and ensures that even heavy doors can be opened more easily manually. The push & go function can be activated on request, i.e. the door is only slightly opened by hand and the automatic activation opens the door completely. In low-energy mode, the drive moves the door at reduced speed. The optional CAN interface can be used to meet demanding requirements e.g. control units for interlocking door systems.

GEZE Slimdrive EMD

71030

8 121650

7211

3

Application range • Internal and external doors • Railway stations and airports • Hotels and gastronomy • Hospitals and nursing homes for the elderly • Educational institutions e.g. schools, nursery schools, day care centres • Leisure facilities, e.g. baths, thermal baths, sport and wellness centres • Administration and public buildings • Food industry

28

Automatic swing door systems

GEZE SLIMDRIVE EMD

GEZE AUTOMATIC DOOR SYSTEMS

Page 29: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Technical data

Product features

GEZ

E S

limdr

ive

EMD

GEZ

E Sl

imdr

ive

EMD

-F

GEZ

E Sl

imdr

ive

EMD

F-I

S

GEZ

E Sl

imdr

ive

EMD

Inve

rs

Height 70 mmWidth 650 mmDepth 121 mmLeaf weight (max.) 1-leaf 180 kg 230 kgHinge clearance (min.-max.) 2-leaf 1500 – 2800 mmLeaf width (min.-max.) 750 – 1400 mmReveal depth (max.)* 400 mmDoor overlap (max.)* 30 mmDrive type ElectromechanicalDoor opening angle (max.)* 115 °Spring pre-load** - EN3 – EN6DIN left ● ● ● ●DIN right ● ● ● ●Transom installation opposite hinge side with link arm ● ● ● ●Transom installation opposite hinge side with roller guide rail ● ● ● ●Transom installation hinge side with roller guide rail ● ● ● ●Door leaf installation hinge side with roller guide rail ● ● - ●Mechanical latching action - ● ● -Electrical latching action ● ● ● ●Electrical closing sequence control ● ● ● ●Mechanical closing sequence control - - ● -Disconnection from mains Cable plug connectionActivation delay (max.) 20 SOperating voltage 230 VFrequency of supply voltage 50 – 60 HzCapacity rating 230 WPower supply for external consumers (24 V DC) 1200 mATemperature range**** -15 – 50 °CIP rating IP20Operating modes Off, Automatic, Permanently open, Exit only, NightType of function Fully automaticAutomatic function ● ● ● ●Low-energy function ● ● ● -Servo function - ● ● ●Key function ● ● ● ●Inverse function (opening by spring force) - - - ●Vestibule function ● ● ● ●Obstacle detection ● ● ● ●Automatic reversing ● ● ● ●Push & Go adjustableOperation Display programme switch DPSParameter setting GEZEconnects, service terminal ST 220CAN interface optionalApprovals DIN 18650

EN 16005DIN 18650

DIN 18263-4EN 16005

DIN 18650DIN 18263-4 Door closing sequence selector tested in accordance with

EN 1158EN 16005

DIN 18650EN 16005

Suitable for fire protection doors - ●*** ●*** -Integrated smoke switch (R-variant) - ●*** ●*** -● = Yes* = Depending on the type of installation** = See table Overview of torques*** = Types of installation: transom installation hinge side with roller guide rail / transom installation opposite hinge side with link arm**** = The door drive is intended for use in dry rooms only

NOTE: THE MAXIMUM POSSIBLE LEAF WEIGHT IN RELATION TO LEAF WIDTH CAN BE FOUND IN THE CHAPTER ON AREAS OF APPLICATION (DIAGRAMS)!

29

Automatic swing door systems

GEZE SLIMDRIVE EMD

Swing door systems

Page 30: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Overview of torques Slimdrive EMD-F

Type of Installation Transom Installation hinge side (min.-max.)

Door leaf Installation hinge side (min.-max.)

Transom Installation opposite hinge side (min.-max.)

Linkage element roller guide rail roller guide rail roller guide rail link armSpring pre-load Closer size EN 1154 4 - 5 5 3 - 5 4 - 6

Closing torques 20 - 45 Nm 17 - 43 Nm 20 - 45 Nm 35 - 70 NmOpening torques, automa-tic 122 - 97 Nm 125 - 96 Nm 115 - 90 Nm max. 150 Nm

Opening torques, manual 45 - 66 Nm 50 - 73 Nm 42 - 65 Nm 61 - 88 NmNote: For automatic mode, the doors must be equipped with suitable hinges. A door stop is necessary.For fire protection doors only the following types of installation: transom installation hinge side with roller guide rail / transom installation opposite hinge side with link arm

EMD, EMD-F, EMD Invers

1-leaf doors Leaf width (min.) Leaf width (max.)Transom installation hinge side with guide rail 850 mm 1250 mm / 1400 mm*Transom installation opposite hinge side with guide rail 850 mm 1250 mm / 1400 mm*Transom installation opposite hinge side with link arm 750 mm 1400 mmDoor leaf installation hinge side with roller guide rail* 850 mm 1250 mm / 1400 mm** Not suitable for fire protection doors!

EMD, EMD-F, EMD F-IS, EMD Invers

2-leaf doors Hinge clearance (min.)

Hinge clearance (max.)

Leaf width (min.) active leaf /

fixed leaf

Leaf width (max.)

Transom installation hinge side / opposite hinge side with guide rail 1700 mm 2500 / 2800* mm 850 mm 1250 / 1400* mm

Transom installation opposite hinge side with link arm 1500 mm 2800 mm 750 mm 1400 mm* Not suitable for fire protection doors!

30

Automatic swing door systems

GEZE SLIMDRIVE EMD

GEZE AUTOMATIC DOOR SYSTEMS

Page 31: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Areas of application

NoteIn low-energy mode the drive moves the swing door at reduced speed, thus fulfilling the safety requirement in DIN 18650 / EN 16005. The use of safety sensors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing area of the door must always be safeguarded with safety sensors.

Slimdrive EMD

0

20

40

60

80

100

120

140

160

180

200

220

240Y

X700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 1400 1450

A B C D1

X = Door width (mm)Y = Door weight (kg)1 = Dashed line: use in installations with roller guide rail

Shortest permitted opening times in areas A-D

Diagram area Opening time Closing timeTransom installation hinge side with roller guide rail

A 3 s 4.5 sB 4 s 5.5 sC 5 s 6.5 sD not permissible

Transom installation opposite hinge side with roller guide railA 4 s 4.5 sB 4.5 s 5.5 sC 5 s 5.5 sD not permissible

Transom installation opposite hinge side with link armA 3 s 4 sB 3 s 4.5 sC 4 s 5.5 sD 5 s 6.5 s

Door leaf installation hinge side with roller guide railA 4 s 4.5 sB 4.5 s 5.5 sC 4.5 s 5.5 sD not permissible

31

Automatic swing door systems

GEZE SLIMDRIVE EMD

Swing door systems

Page 32: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

NoteWe recommend the use of link arms for external doors. Wind loads and underpressure or excess pressure must also be taken into account. Dimensions marked by an asterisk (*) are valid for direct attachment.

Slimdrive EMD-F and Slimdrive EMD Invers

0

20

40

60

80

100

120

140

160

180

200

220

240

700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 1400 1450

A B C D

Y

X

1

X = Door width (mm)Y = Door weight (kg)1 = Dashed line: Use in installations with roller guide rail

Shortest possible opening times in areas A-D (set values for ST 220 and DPS)

Diagram area Opening time Closing timeTransom installation hinge side with roller guide rail

A 3,5 s 4,5 sB 4 s 5 sC 4 s 5,5 sD not permissible

Transom installation opposite hinge side with roller guide railA 5 s 4,5 sB 6 s 5 sC 6,5 s 5,5 sD not permissible

Transom installation opposite hinge side with link armA 3,5 s 4,5 sB 4 s 5 sC 4,5 s 5,5 sD 5 s 6 s

Door leaf installation hinge side with roller guide railA 3,5 s 4,5 sB 4 s 5,5 sC 4,5 s 6 sD not permissible

32

Automatic swing door systems

GEZE SLIMDRIVE EMD

GEZE AUTOMATIC DOOR SYSTEMS

Page 33: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Installation with mounting plate (A) and direct installation (B)

A B

620577

394256

7330

max

. 20

89 698

1

2

3

max

. 20

4

620540

412274

3014

max. 20

4

1

2

3

89 698

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for sensors, door opener, programme switch and lock switch contact3 = Concealed cable routing 230 V / 50 Hz4 = Door leaf width

Transom installation with roller guide rail on the hinge side, single-leafDrawing no. 70106-ep01 Door overlap (max.) 30 mmDoor opening angle (max.) 105°

* = Direct installation1 = Space needed for EMD-F/EMD Invers2 = Space needed for roller guide rail3 = Space needed for sensor strips

1218

95

1414

1443

10

50

20

70

3939

51,2

*

38

1

23

*

33

Automatic swing door systems

GEZE SLIMDRIVE EMD

Swing door systems

Page 34: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Installation with mounting plate (A) and direct installation (B)

598577

394256

7352

82698

12

3

A

636598

376238

11052

max. Ø 20

698 82

max

. Ø 2

0

B

1

4

2

3

max. Ø 20

max

. Ø 2

0

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for sensors, door opener, programme switch and lock switch contact3 = Concealed cable routing 230 V / 50 Hz4 = Door leaf width

Transom installation with roller guide rail on the opposite hinge side, single-leafDrawing no. 70106-ep02Reveal depth (max.) -30 to +50 mmDoor opening angle (max.) 105°

* = Direct installation1 = Space needed for EMD-F/EMD Invers2 = Space needed for roller guide rail3 = Space needed for sensor strips

1218

9075

39

39 39

70

29

1414

1443

51,2

*38

*

1

3

2

34

Automatic swing door systems

GEZE SLIMDRIVE EMD

GEZE AUTOMATIC DOOR SYSTEMS

Page 35: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Installation with mounting plate (A) and direct installation (B)

1

2

3

4

598577

394256

7352

44 417

max

. Ø 2

0

max. Ø 201

2

3

4

max

. Ø 2

0

636376

238110

52

41744

max. Ø 20

A B

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for sensors, door opener, programme switch and lock switch contact3 = Concealed cable routing 230 V / 50 Hz4 = Door leaf width

Transom installation with link arm on the opposite hinge side, single-leaf Drawing no. 70106-ep03Reveal depth (max.) 0-100 mm, 100-200 mm, 200-300 mmDoor opening angle (max.) 110°

* = Direct installation1 = Space needed for EMD-F/EMD Invers2 = Space needed for link arm3 = Space needed for sensor strips

1218

95

75

47

39 39

75

4814

1414

34

51,2

*

43*

1

3

2

35

Automatic swing door systems

GEZE SLIMDRIVE EMD

Swing door systems

Page 36: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Door leaf installation with roller guide rail on the hinge side, single-leaf Drawing no. 70106-ep04Door overlap (max.) 30 mmDoor opening angle (max.) 115°

* = Direct installation1 = Space needed for EMD-F/EMD Invers2 = Space needed for roller guide rail3 = Space needed for sensor strips

Installation with mounting plate (A) and direct installation (B)

Ø 20

69 748

82

666628

406268

140

69 748

82

628607

424286

103

Ø 20

A B

22

4 4

3 3

11 Ø 20Ø 20

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for sensors, door opener, programme switch and lock switch contact3 = Concealed cable routing 230 V / 50 Hz4 = Door leaf width

3939

100

8

120

29 3970

4314

1414

121

38 *

51.2

* 1

2

33

36

Automatic swing door systems

GEZE SLIMDRIVE EMD

GEZE AUTOMATIC DOOR SYSTEMS

Page 37: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Installation with mounting plate (A) and direct installation (B)

89 698 89698

1430

274412

540620

662

14

662

540620

412274

30

8969889 698

30

721620

577394

25673

30

577620

721

394256

73

Ø 20

Ø 20

Ø 20

Ø 20

B

A

2

1

3

1

3

1

144

4 4

5

5

2

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for sensors, door opener, programme switch and lock switch contact3 = Concealed cable routing 230 V / 50 Hz4 = Door leaf width5 = Hinge clearance

Transom installation with roller guide rail on the hinge side, double-leafDrawing no. 70106-ep21

1218

95

1414

1443

10

50

20

703939

51,2

*

38*

1

23

* = Direct installation1 = Space needed for EMD-F/EMD Invers2 = Space needed for roller guide rail3 = Space needed for sensor strips

37

Automatic swing door systems

GEZE SLIMDRIVE EMD

Swing door systems

Page 38: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Transom installation with roller guide rail on the opposite hinge side, double-leafDrawing no. 70106-ep22

1218

9072

3939 39

70

29

1414

1443

51,2

*38

*

1

3

2

* = Direct installation1 = Space needed for EMD-F/EMD Invers2 = Space needed for roller guide rail3 = Space needed for sensor strips

Installation with mounting plate (A) and direct installation (B)

8269882 698

394577

598

5273

256

721 721

5273

256394

577598

698 8282 698

662

52

376238

110

636598

662636

52

376238

110

598

A

B

1

2

2

3

4 4

4

5

5

Ø 20

Ø 20

Ø 20

Ø 20

31

1

1

4

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for sensors, door opener, programme switch and lock switch contact3 = Concealed cable routing 230 V / 50 Hz4 = Door leaf width5 = Hinge clearance

38

Automatic swing door systems

GEZE SLIMDRIVE EMD

GEZE AUTOMATIC DOOR SYSTEMS

Page 39: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Installation with mounting plate (A) and direct installation (B)

417 44 41744

636662

598

110238

376

52

636662

598

110238

376

52

417 44 41744

52

721

256394

577598

7352

721598

577394

25673

A

B

1

1 1

1Ø 20

Ø 20

Ø 20

Ø 20

2

2

3

3

4 4

5

5

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for sensors, door opener, programme switch and lock switch contact3 = Concealed cable routing 230 V / 50 Hz4 = Door leaf width5 = Hinge clearance

Transom installation with link arm on the opposite hinge side, double-leafDrawing no. 70106-ep23

1218

95

75

47

39 39

75

4814

1414

34

51,2

*

43*

1

3

2

* = Direct installation1 = Space needed for EMD-F/EMD Invers2 = Space needed for link arm3 = Space needed for sensor strips

39

Automatic swing door systems

GEZE SLIMDRIVE EMD

Swing door systems

Page 40: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Door leaf installation with roller guide rail on the hinge side, double-leaf Drawing no. 70106-ep24

3939

100

8

120

29 3970

4314

1414

121

38*

51.2*

1

2

33

* = Direct installation1 = Space needed for EMD-F/EMD Invers2 = Space needed for roller guide rail3 = Space needed for sensor strips

Installation with mounting plate (A) and direct installation (B)

6974869 748

82

628607

424286

10382

628607

424286

103

69 748 69748

82

666

406628

268140

82

666628

406268

140

A

B

1

1

1

1

Ø 20

Ø 20

2

2

3

3

Ø 20

Ø 20

4 4

4 4

5

5

A = Installation with mounting plateB = Direct installation1 = Dimensional reference centre of hinge2 = Concealed cable routing for sensors, door opener, programme switch and lock switch contact3 = Concealed cable routing 230 V / 50 Hz4 = Door leaf width5 = Hinge clearance

40

Automatic swing door systems

GEZE SLIMDRIVE EMD

GEZE AUTOMATIC DOOR SYSTEMS

Page 41: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Legend for the cable diagrams

Cable1 = NYM-J 3 x 1.5 mm2

2 = J-Y(ST)Y 1 x 2 x 0.6 LG3 = J-Y(ST)Y 2 x 2 x 0.6 LG4 = J-Y(ST)Y 4 x 2 x 0.6 LG5 = LiYY 2 x 0.25 mm2

6 = LiYY 4 x 0.25 mm2

7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2

8 = Route empty pipe with pull-wire inner diameter 10 mm

Notes • Cable diagrams can also be prepared for specific building projects after receipt of order • Version of standard cable diagrams in accordance with GEZE specifications • Cable routing according to VDE0100/ IEE regulations • Allow the cable for the drive to project at least 1500 mm out of the wall

1) Door transmission cable (including in the scope of supply for sensor strip), cable routing through a hole in the door leaf is not permitted for fire protection doors.2) Cable exit for door drive, see installation drawings for Slimdrive EMD/EMD-F 70106-ep01 to -ep043) Cable including in the scope of supply for the sensor4) Install in the direct vicinity of the door5) Mains connection box WxHxD min. 65 x 65 x 57 with PG-11 duct, on site6) Low-voltage connection box WxHxD min. 94 x 65 x 57 with PG-11 duct, on site7) E.g. door transmission cable, 8-wire, art. no. 0669228) Branch box, on site

AbbreviationsHS = Main switchNOT = Emergency-stop switchUT = Circuit breaker CLOSE DOOR (only with F variant)KB = Contact sensor authorisedPS = Programme switchST = Emergency stopKI = Contact sensor insideKA = Contact sensor outsideTOE = Door openerRM = Bar messageRS = Smoke switch (only with F variant)RSZ = Smoke switch control unit (only with F variant)TS = Door closerMK = Magnetic contact

41

Automatic swing door systems

GEZE SLIMDRIVE EMD

Swing door systems

Page 42: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

I = Feeder 230 V / 50 HzII = 10 A fuseIII = Connected value 230 W, 1 A 1-, 2-leaf with manual fixed leaf; connected value 460 W, 1 A with 2-leafIV = And / OrV = Option

B+200

B/2

B

B/2

KI

KA

max. 100

max

. 300

5)

6)

EMD/EMD-F

1-leaf

RS 3 3RSRS 33RS

7

88

8)

C

A

B

D

C

A

B

D

3 3

6)

5)1RSZ

RMTOE

1

12

RSZ

2)

1)

8

RMTOE

2)

GC 338 GC 338

EMD/EMD-FEMD/EMD-F

I II

2-leaf

8

D*83

2)2)2)

*

83

1

D

7

7

C

A

B

DC

A

B

D

6

1

6)

5)

6)

5)

RM

3

1

TOE

RSZ

RMTOE

RM

3

1

1TOE

2

RSZ

2)

1)

8

RMTOE

8)

8

8

7)

4

7

RS 3 3RSRS 3 3RS

6

GC 338 GC 338 GC 338 GC 338

III IVIII IV

EMD/EMD-F

I II

EMD/EMD-F EMD/EMD-F EMD/EMD-F

I   = Transom installationII  = Door leaf installationIII  = Fixed leafIV  = Active leaf

3)3)KA

388

3221 11 1

KB

3

KI

3

ST

3

PS

D/D*

BA

C

HS NOT UT4)

III

II

I

IV

VV

42

Automatic swing door systems

GEZE SLIMDRIVE EMD

GEZE AUTOMATIC DOOR SYSTEMS

Page 43: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

GEZE TSA 160 NT swing door drive

Electrohydraulic swing door drive for 1 and 2-leaf single-action doors

TSA 160 NT is an electronically controlled hydraulic swing door system for single-action doors made of wood, steel, aluminium or plastic with leaf weights of up to 250 kg and leaf widths of up to 1400 mm. The drive works with a hydraulic pump system during opening. The closing process is by means of a closing spring mechanism and adjustable hydraulic valves. TSA 160 NT also has low power consumption and is low-maintenance. The door can be opened by hand in the event of a power failure. Manual opening is also possible with motor operation switched on. A reinforced and highly stable link arm meets the requirements of large and heavy doors which are highly frequented. The TSA 160 NT masters large amounts of foot traffic reliably and easily.

GEZE TSA 160 NT

690

150

100

1218

30465

Application range • Internal and external doors • Railway stations and airports • Hotels and gastronomy • Hospitals and nursing homes for the elderly • Department stores and shopping centre • Educational institutions e.g. schools, nursery schools, day care centres • Leisure facilities, e.g. baths, thermal baths, sport and wellness centres • Administration and public buildings • Food industry

43

Automatic swing door systems

GEZE TSA 160 NT

Swing door systems

Page 44: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Technical data

Product features

GEZ

E TS

A 1

60 N

T

GEZ

E TS

A 1

60 N

T-F

GEZ

E TS

A 1

60 N

T In

vers

GEZ

E TS

A 1

60 N

T IS

GEZ

E TS

A 1

60 N

T F-

IS

Height 100 mmWidth 690 mmDepth 121 mmLeaf weight (max.) 1-leaf 250 kgHinge clearance (min.-max.) 2-leaf 1470 – 2800 mmLeaf width (min.-max.) 690 – 1400 mmReveal depth (max.)* 400 mmDoor overlap (max.)* 20 mmDrive type ElectrohydraulicDoor opening angle (max.)* 115 °Spring pre-load** EN3 – EN6Z-variant (pulling) ● - - ● -Z-variant (pushing) - - ● ● -DIN left ● ● ● ● ●DIN right ● ● ● ● ●Transom installation opposite hinge side with link arm ● ● ● ● ●Transom installation hinge side with roller guide rail ● - ● ● -Mechanical latching action ● ● - ● ●Electrical closing sequence control ● ● ● ● ●Mechanical closing sequence control - - - ● ●Disconnection from mains Not availableActivation delay (max.) 10 SOperating voltage 230 VFrequency of supply voltage 50 – 60 HzCapacity rating 300 WPower supply for external consumers (24 V DC) 1200 mA

Temperature range*** -15 – 60 °CIP rating IP20Operating modes Off, Automatic, Permanently open, Exit only, NightType of function Fully automaticAutomatic function ● ● ● ● ●Key function ● ● ● ● ●Inverse function (opening by spring force) - - ● - -Vestibule function ● ● ● ● ●Obstacle detection ● ● ● ● ●Automatic reversing ● ● ● ● ●Push & Go adjustableOperation Display programme switch DPSParameter setting GEZEconnects, service terminal ST 220Approvals DIN 18650, EN 16005Use on fire and smoke protection doors (F-variant)

- ●**** - - ●****

● = Yes* = Depending on the type of installation** = See table overview of torques*** = The door drive is intended for use in dry rooms only**** = Only for type of installation transom installation opposite hinge side with link arm

NOTE: THE MAXIMUM POSSIBLE LEAF WEIGHT IN RELATION TO LEAF WIDTH CAN BE FOUND IN THE CHAPTER ON AREAS OF APPLICATION (DIAGRAMS)!

44

Automatic swing door systems

GEZE TSA 160 NT

GEZE AUTOMATIC DOOR SYSTEMS

Page 45: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

pushing (min.-max.) pulling (min.-max.)Spring pre-loadCloser size EN 1154 3 - 6 2 - 5

Closer torques:torque exerted by the closing spring during automatic opening

20 Nm - 60 Nm 8 Nm - 30 Nm

Opening torque:torque exerted by the door during automatic opening

150 Nm - 90 Nm 70 Nm - 40 Nm

Opening torque:manual torque to be exerted for door opening

35 Nm - 110 Nm 13 Nm - 45 Nm

Note: For automatic mode, the doors must be equipped with suitable hinges. A door stop is necessary.

TSA 160 NT minimum and maximum leaf widths

1-leaf doors Leaf width (min.) Leaf width (max.)TSA 160 NT pushing1) 690 mm 1400 mm

TSA 160 NT pulling950 mm (with operator displacement=0)

890 mm (with operator displacement=60 mm)1400 mm

TSA 160 NT Z 690 mm 1400 mm1) Also on smoke and fire protection doors

TSA 160 NT minimum and maximum leaf widths, hinge clearance for 2-leaf doors

2-leaf doors Hinge clearance (min.)

Hinge clearance (max.)

Leaf width (min.) active leaf2)

Leaf width (min.) fixed leaf2) Leaf width (max.)

TSA 160 NT IS pushing1) 1470 mm 2800 mm 690 mm 400 mm 1400 mm

TSA 160 NT Z-IS pulling 1470 mm 2800 mm 690 mm 650 mm 1400 mm

TSA 160 NT IS/TS pushing1) 1260 mm 2800 mm 690 mm 400 mm 1400 mm

TSA 160 NT IS/TS pulling 1360 mm 2800 mm 690 mm 650 mm 1400 mm

1) Also on smoke and fire protection doors2) The minimum hinge width must be observed!

Overview of torques TSA 160 NT

Areas of application

TSA 160 NT

X = Door width (mm)Y = Door weight (kg)1 = Link arm2 = Roller guide rail

50

100

150

200

250

300

700 800 900 1000 1100 1200 1300 1400

Y

X

2

1

45

Automatic swing door systems

GEZE TSA 160 NT

Swing door systems

Page 46: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

587

625

50

48

186 453

34 420

50

50

587

20

162.5

186 453

325

650487.5

A B

1

1 1 1Ø 20

Ø 20

Ø 20 Ø 20

A = Direct installationB = Installation with mounting plate1 = Concealed cable routing

Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).

Transom installation with roller guide rail on the hinge side, single-leafDrawing no. 70423-ep02

* = Installation with mounting plate1 = Space needed for TSA 160 NT2 = Space needed for roller guide rail3 = Space needed for sensor strips

80

31

31

50

119

29*

29*

22*

29*

8* 121

63

54

42

1

2

3

46

Automatic swing door systems

GEZE TSA 160 NT

GEZE AUTOMATIC DOOR SYSTEMS

Page 47: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

453 X

1

1 = Mounting plate

TSA 160 NT

Soffit depth L(from-to)

Dimension X for roller guide rail with TSA 160 NT Z Door width (min.) Opening angle

> 0 - 25 mm 186 mm 690 mm 109° - 113°> 25 - 50 mm 192 mm 690 mm 113° - 115°> 50 - 75 mm 203 mm 690 mm 115° - 110°> 75 - 100 mm 215 mm 690 mm 110° - 105°> 100 - 125 mm 229 mm 690 mm 105° - 100°> 125 - 150 mm 244 mm 703 mm 100° - 97°> 150 - 175 mm 262 mm 721 mm 97° - 95°> 175 - 200 mm 280 mm 739 mm 95° - 90°

47

Automatic swing door systems

GEZE TSA 160 NT

Swing door systems

Page 48: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

587

48

625

50

335

44

34 420

587

44

50

50

335

20 162.5

1029

2229

325

650487.5

Ø 20 Ø 20

Ø 20

Ø 20

A B

1 1

1

1

A = Direct installationB = Installation with mounting plate1 = Concealed cable routing

Transom installation with link arm on the opposite hinge side, single-leaf Drawing no. 70423-ep01

* = Installation with mounting plate1 = Space needed for TSA 160 NT2 = Space needed for link arm3 = Space needed for sensor strips

85

41*

39

4 40

8*121

29*

29*

22*

100

27+X

54

1

2

3

48

Automatic swing door systems

GEZE TSA 160 NT

GEZE AUTOMATIC DOOR SYSTEMS

Page 49: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Transom installation with roller guide rail on the hinge side, double-leafDrawing no. 70423-ep22

50

31

8060

8* 121

2929

*22

*29

*

11954

42

3

2

1

* = Installation with mounting plate1 = Space needed for TSA 160 NT2 = Space needed for roller guide rail3 = Space needed for sensor strips

587

625 625

50

48

3442034 420

186 453

186453

58750

50

186453

20 162.5 20162.5

186 453

325

650487.5

325

B/2650

487.5

A

B

1

1

1

1

2Ø 20

Ø 20

Ø 20

Ø 20

A = Direct installationB = Installation with mounting plate1 = Concealed cable routing2 = only required for B > 2000

49

Automatic swing door systems

GEZE TSA 160 NT

Swing door systems

Page 50: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

44

335

44

335

587

50

50

B /2

20 162.5 20162.5

487.5650

325

650487.5

325

Ø 20Ø 20

A

B

1 1

2

44

335

44

335

587

48

50

625 625

34 420 34420

Ø 20

Ø 20 1

1

A = Direct installationB = Installation with mounting plate1 = Concealed cable routing2 = only required for B > 2000

Transom installation with link arm on the opposite hinge side, double-leafDrawing no. 70423-ep11

3985

max. 350

X

86

5529

*22

*29

*

8*12110

0

40

5154

1

2

3

X = Spindle extension* = Installation with mounting plate1 = Space needed for TSA 160 NT2 = Space needed for link arm3 = Space needed for sensor strips

50

Automatic swing door systems

GEZE TSA 160 NT

GEZE AUTOMATIC DOOR SYSTEMS

Page 51: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Legend for the cable diagrams

Cable1 = NYM-J 3 x 1.5 mm2

2 = J-Y(ST)Y 1 x 2 x 0.6 LG3 = J-Y(ST)Y 2 x 2 x 0.6 LG4 = J-Y(ST)Y 4 x 2 x 0.6 LG5 = LiYY 2 x 0.25 mm2

6 = LiYY 4 x 0.25 mm2

7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2

8 = Route empty pipe with pull-wire inner diameter 10 mm

Operator displacement AV = Cable exit60 mm = 580 mm50 mm = 590 mm40 mm = 600 mm (standard)30 mm = 610 mm20 mm = 620 mm10 mm = 630 mm0 mm = 640 mm

Notes • Cable diagrams can also be prepared for specific building projects after receipt of order • Version of standard cable diagrams in accordance with GEZE specifications • Cable routing according to VDE0100/ IEE regulations • Allow the cable for the drive to project at least 1500 mm out of the wall

1) Door transmission cable (including in the scope of supply for sensor strip), cable routing through a hole in the door leaf is not permitted for fire control doors.2) Cable exit for door drive see sketch A and B3) Cable including in the scope of supply for the sensor4) Install in the direct vicinity of the door7) E.g. door transmission cable, 8-wire, art. no. 0669228) Branch box, on site

AbbreviationsHS = Main switchNOT = Emergency-stop switchUT = Circuit breaker CLOSE DOOR (only with F variant)KB = Contact sensor authorisedPS = Programme switchST = Emergency stopKI = Contact sensor insideKA = Contact sensor outsideTOE = Door openerRM = Bar messageRS = Smoke switch (only with F variant)RSZ = Smoke switch control unit (only with F variant)TS = Door closerMK = Magnetic contact

51

Automatic swing door systems

GEZE TSA 160 NT

Swing door systems

Page 52: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Positioning of the movement detectors

B/2

B+200 B+200

BWM

B/2

B

BWMB

2xB

B+200

B

KI

KAKA

KI

B/2

B+200

B

I II III

I = Positioning of movement detector 1-leafII = Positioning of movement detector 2-leafIII = Positioning of movement detector 2-leaf, 2E

I = Feeder 230 V / 50 HzII = 10 A fuseIII = Connected value 300 W 1.3 A for 1- 2-leaf with manual fixed leaf Connected value 600 W 2.6 A for 2-leafIV = And / OrV = Option

3)3)

KA

388

3221 11 1

KB

3

KI

3

ST

3

PS

D/D*

BA

C

HS NOT UT

4)

III

II

I

IV

V9)

52

Automatic swing door systems

GEZE TSA 160 NT

GEZE AUTOMATIC DOOR SYSTEMS

Page 53: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

TSA 160 NT cable plan  single-leaf

TSA 160 NT

TOERM

8

1)

2)

RSZ

2 1

1

GC 338

3

D

B

A

C

8)

8

RS 3 3RS

TSA 160 NT cable plan  double-leaf

6

RS 33RSRS 33RS

82

MK

8)

3

4

7)

8

8)8)

2

C

A

B

D

6

TSRM

1

1TOE

2

7)

RSZ

2)

1)

8

RMTOE

TOERM

8

1)

2)

RSZ

GC 338

2TOE

1

1

3

RMTSA 160 NT

D

B

A

C

7

D

1

3 8

* 2)

8

8

38

GC 338GC 338

I II

TSA 160 NTTSA 160 NT

III IVIII IV

I = 2-leafII = 2-leaf with manual fixed leafIII = Fixed leafIV = Active leaf

TSA 160 NT cable exit

68

ø 20600

AV=40

68

ø 20600

AV=40

IV V

VI VI

VII VII

54

ø2050

54

ø 2050

IV V

VI VI

VII VII

68

50ø 20

68

50ø 20

IV V

VI

VII VII

VI

I II III

AV = Operator displacementI = TSA 160 NT installation hinge sideII = TSA 160 NT installation opposite hinge sideIII = TSA 160 NT-Z installation hinge sideIV = Drive left - pullingV = Drive right - pullingVI = from top of leaf, dimension for spindle extensions must be addedVII = Cable exit

53

Automatic swing door systems

GEZE TSA 160 NT

Swing door systems

Page 54: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

54

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

GEZE Powerturn swing door drive

Fully automatic swing door drive for 1 and 2-leaf single-action doors

The Powerturn swing door drive offers comfort and safety for every access situation. The fully automatic drive is powerful and opens even large, heavy doors with leaf weights up to 600 kg at door widths of 930 mm reliably and safely. GEZE’s powerful model is also the perfect solution for fire protection doors with leaf weights up to 600 kg. It offers freedom to design for a wide range of uses. The unique „Smart swing“ function allows for easy manual use even of large, heavy doors, e.g. fire protection doors or façade doors, at any time. The powerful closing spring is once pre-tensioned and does not have to be moved permanently during passage. In addition, the „Smart swing“ function reduces energy costs during operation and in the „permanently open“ position. The small overall height and discreet design make it flexible and future-proof for multifunction safety doors, safe escape and rescue routes and complex interlocking door systems. This makes Powerturn an excellent example of „Universal Design - made in Germany“. Installation is straightforward and safe due to the simple GEZE installation system.

Area of application • Internal and external doors • Railway stations and airports • Hotels and gastronomy • Hospitals and homes for the elderly • Department stores and shopping centres • Educational institutions, e.g. schools, nursery schools, day care centres • Leisure facilities, e.g. baths, thermal baths, sport and wellness centres • Administration and public buildings • Food industry

GEZE Powerturn

Page 55: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

55

Automatic swing door systems

GEZE POWERTURN

Swing door systems

Technical data

Product features

GEZ

E Po

wer

turn

GEZ

E Po

wer

turn

F

GEZ

E Po

wer

turn

F/

R

GEZ

E Po

wer

turn

F-

IS

GEZ

E Po

wer

turn

F/

R-IS

GEZ

E Po

wer

turn

IS

/TS

GEZ

E Po

wer

turn

F-

IS/T

S

GEZ

E Po

wer

turn

F/

R-IS

/TS

Height 70 mmWidth 720 mm 920 mmDepth 130 mmLeaf weight (max.) 1-leaf 600 kgHinge clearance (min.-max.) 2-leaf link arm 1600 – 3200 mm 1270 – 3200 mmHinge clearance (min.-max.) 2-leaf roller guide rail 1600–

3200 mm1600 – 2800 mm

1380–3000 mm

1380 – 2800 mm

Leaf width (min.-max.)* 800 – 1600 mm 470 – 1600 mmReveal depth (max.)* 560 mm 300 mm 160 mmDrive type ElectromechanicalDoor opening angle (max.)* 136 °Spring pre-load** EN4 – EN7 EN1 - EN7DIN left ● ● ● ● ● ● ● ●DIN right ● ● ● ● ● ● ● ●Transom installation opposite hinge side with link arm ● ● ● ● ● ● ● ●Transom installation opposite hinge side with roller guide rail ● ● ● ● ● - - -Transom installation hinge side with roller guide rail ● ● ● ● ● ● ● ●Door leaf installation opposite hinge side with roller guide rail ● ● - - - - - -Door leaf installation hinge side with roller guide rail ● ● - - - - - -Door leaf installation hinge side with link arm ● ● - - - - - -Mechanical latching action ● ● ● ● ● ● ● ●Electrical latching action ● ● ● ● ● ● ● ●Electrical closing sequence control ● ● ● ● ● - - -Mechanical closing sequence control*** - - - ● ● ● ● ●Disconnection from mains all pole main switch in the driveActivation delay (max.) 10 sOperating voltage 230 VFrequency of supply voltage 50 – 60 HzCapacity rating 200 WPower supply for external consumers (24 V DC) 1200 mA per driveTemperature range**** -15 – 50 °CIP rating IP30Operating modes Automatic, Night, Permanently open, Exit only, OffType of function Fully automaticAutomatic function ● ● ● ● ● ● ● ●Low-Energy function ● ● ● ● ● ● ● ●Smart swing function ● ● ● ● ● ● ● ●Key function ● ● ● ● ● ● ● ●Vestibule function ● ● ● ● ● ● ● ●Obstacle detection ● ● ● ● ● ● ● ●Automatic reversing ● ● ● ● ● ● ● ●Push & Go adjustableOperation GEZEconnects (PC + Bluetooth), Service terminal ST 220, Display programme switch

DPSParameter setting GEZEconnects, service terminal ST 220Approvals DIN 18650,

EN 16005, DIN 18263-4

DIN 18650, EN 16005, Door closing sequence selector tested in accordance

with EN 1158Suitable for fire protection doors - ● ● ● ● - ● ●Integrated smoke switch (R-variant) - - ● - ● - - ●● = YES* = DEPENDING ON THE TYPE OF INSTALLATION** = SEE TORQUE OVERVIEW TABLE*** = TYPES OF INSTALLATION: TRANSOM INSTALLTION WITH LINK ARM/ROLLER GUIDE RAIL**** = THE DOOR DRIVE IS INTENDED FOR USE IN DRY ROOMS ONLY

NOTE: THE MAXIMUM POSSIBLE LEAF WEIGHT IN RELATION TO LEAF WIDTH CAN BE FOUND IN THE CHAPTER ON AREAS OF APPLICATION CHARTS)!

Page 56: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

56

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Technical data for use of the IS/TS variant

* Standard package with TS 4000 EN 1-6, on request via Customer Solutions there is the option for the use of the GEZE TS 4000 EN 5-7

GEZE Powerturn IS/TS with TS 5000 L door closer

GEZE Powerturn IS/TS with TS 4000 door closer

Element Active leaf Passive leaf SystemDrive/door closer GEZE Powerturn GEZE Powerturn F

GEZE Powerturn F/RTS 5000 L Powerturn IS/TS Powerturn F-IS/TS

Powerturn F/R-IS/TSLever type Roller guide rail Guide railMin. - max. leaf width 800 - 1600 mm 800 - 1400 mm 580 - 1400 mmMin. - max. hinge size 1380 - 3000 mm 1380 - 2800 mm

1.500 - 2.800 mm(F/R variant)

Reveal 0 mmEN closing force EN 4-6 EN 2-6 EN 3-6

Element Active leaf Passive leaf SystemDrive/door closer GEZE Powerturn GEZE Powerturn F

GEZE Powerturn F/RTS 4000 EN 1-6

or EN 5-7Powerturn IS/TS Powerturn F-IS/TS

Powerturn F/R-IS/TSLever type Link arm Link armMin. - max. leaf width 800 - 1600 mm 470 - 1600 mmMin. - max. hinge size 1270 - 3200 mm 1270 - 3200 mm

1.500 - 3.200 (F/R variant)Reveal 0 - 160 mmEN closing force EN 6-7 EN 1-7* EN 3-7

Page 57: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

57

Automatic swing door systems

GEZE POWERTURN

Swing door systems

X = Door width (mm)Y = Door weight (kg)

Diagram showing the use of Powerturn with opening times of up to 90° door opening angle

Area of applicationNoteThe movement parameters can be set in such a way that the safety requirements for low-energy operation in compliance with DIN 18650 / EN 16005 are met. The drive then moves the swing door at reduced speed. The use of safety sensors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing area of the door must always be safeguarded with safety sensors.

Opening times PowerturnTo ensure the safety requirements in low-energy operation

Illustration of the minimum opening times to be set depending on the door weight and door leaf width for a door opening from 0° to 80° or for a closing movement from 90° to 10° door opening angle.

020406080

100120140160180200220240260280300320340360380400420440460480500520540560580600620

700 800 900 1000 1100 1200 1300 1400 1500 1600 1700

3s 4s 6s 5s

X

Y

���

���

���

��

Door weight (kg)

Leaf

wid

th (m

m)

60 90 120 150 180 210 240 270 300 330 370 400 430 460 490 520 550 580 600800 4 4 5 5 6 6 7 7 7 8 8 8 9 9 9 10 10 10 10900 4 5 5 6 7 7 7 8 8 9 9 9 10 10 11 11 11 11 11

1000 4 5 6 7 7 8 8 9 9 10 10 10 11 11 12 121100 5 6 6 7 8 8 9 9 10 10 11 11 121200 5 6 7 8 8 8 10 10 11 11 121300 6 7 8 8 9 10 11 11 12 121400 6 7 8 9 10 11 11 121500 6 8 9 10 11 111600 7 8 9 10 11 12

Page 58: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

58

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

K-BSrail

K-BGSrail

T-BSrail

T-BGSrail

K-BGS link arm

T-BSlink arm

Min Max Min Max Min Max Min Max Min Max Min MaxEN 1154 EN class 4 6 4 6 4 6 4 6 6 7 6 7Closing torques Nm (door) 0 60 0 60 0 60 0 60 0 100 0 100Maximum opening torque (automatic) Nm (door) 135 121 143 127 180* 180*

Manual opening torque (Operating mode Off)

Nm (door) 10 9 11 10 19 21

Overview of Powerturn torques

* = Restricted according to DIN 18263-4 K = Transom installationT = Door leaf installation

BS = Hinge sideBGS = Opposite hinge side

Note: For automatic mode, the doors must be equipped with suitable hinges. A door stop is necessary.

Type of installation Dimension Powerturn Powerturn FTransom installation hinge side rail

Reveal depth LT [mm] 0–100 5) (60–200) 1, 5)

0–100

Door overlap Ü [mm] 0–30Max. door opening angle TÖW [°] approx. 102–133 2)

Standard roller guide rail L = [mm] 687Lever L = [mm] 330Hinge size [mm] 190EN class 4-6

Transom installation opposite hinge side railReveal depth LT [mm] max. 100Max. door opening angle TÖW [°] approx. 108 3)

Standard roller guide rail L = [mm] 687Lever L = [mm] 450Hinge size [mm] 190EN class 4-6

InstallationPowerturn can be installed in the following ways, each in DIN left and DIN right:

Page 59: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

59

Automatic swing door systems

GEZE POWERTURN

Swing door systems

Type of installation Dimension Powerturn Powerturn FDoor installation hinge side rail

Reveal depth LT [mm] 0–50Door overlap Ü [mm] 0–30Max. door opening angle TÖW [°] approx. 126 3)

Standard roller guide rail L = [mm] 734Lever L = [mm] 330Hinge size [mm] 220EN class 4–6

Door installation opposite hinge side railReveal depth LT [mm] 0Max. door opening angle TÖW [°] approx. 104Standard roller guide rail L = [mm] 734Lever L = [mm] 450Hinge size [mm] 220EN class 4–6Max. door leaf thickness [mm] 100

Door installation hinge side link armReveal depth LT [mm] 0Door overlap Ü [mm] 0–30 0Hinge size [mm] 220Max. door opening angle TÖW [°] approx. 115EN class 6–7

Transom installation opposite hinge side link armStandard reveal depth LT [mm] up to 510 up to 300Reveal depths LT with link arm adapter for sensor link arm [mm]

up to 560 up to 300

Max. door leaf thickness [mm] 150Max. door opening angle TÖW [°] approx. 110–135 2,3,4)

Hinge size [mm] 190EN class 6–7

1) With lever (450 mm)2) Refer to the following charts to determine the max. door opening angle3) TÖW through a collision between the lever/drive and the door/frame4) Transom installation opposite hinge side link arm/reveal – max. door opening angle chart – see below5) –Transom installation hinge side rail/reveal – max. door opening angle chart – see below

Page 60: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

60

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Reveal / max. door opening angleTransom installation opposite hinge side link arm

X = Reveal depth (mm)Y = Max. door opening angle (°)1 = Door opening angle2 = Door opening angle with sensor link arm

0

20

40

60

80

100

120

140

160

0 50 100 150 200 250 300 350 400 450 500

X

Y1

2

Transom installation hinge side roller guide rail

* = PreloadX = Reveal depth (mm)Y = Max. door opening angle (°)1 = Lever 330 mm2 = Lever 450 mm

80

90

100

110

120

130

140

0 20 40 60 80 100 120 140 160 180 200

*

*

*

*

X

Y 1 2

Page 61: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

61

Automatic swing door systems

GEZE POWERTURN

Swing door systems

Transom installation with roller guide rail on the hinge side, 1-leaf and 2-leafDrawing no. 70109-ep01

* = Important functional dimensionAV = Spindle extension1 = Base upper edge of door2 = Space needed for sensor strips

4 4

A B

A = DIN leftB = DIN right1 = Dimensional reference centre of hinge / upper edge of door2 = Concealed cable routing possible in the hatched area, e.g. Ø 20 mm for the mains connection or low voltage connection3 = Orientation arrow for precise positioning of the mounting plate4 = Hinge size

Mounting plate fitting dimensions

107 1071

1 = Base plate

2-leaf installation with intermediate cover with divided or continuous cover

130

X 2=92

+AV

26

42X 1 =

36

+ A

V10

1010

22

50 505050

7*

1

22

Page 62: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

62

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Transom installation with roller guide rail on the opposite hinge side, 1-leaf and 2-leaf Drawing no. 70109-ep02

* = Important functional dimensionAV = Spindle extension1 = Base lower edge of lintel2 = Space needed for sensor strips

4 4

A B

A = DIN leftB = DIN right1 = Dimensional reference centre of hinge / lower edge of frame2 = Concealed cable routing possible in the hatched area, e.g. Ø 20 mm for the mains connection or low voltage connection3 = Orientation arrow for precise positioning of the mounting plate4 = Hinge size

Mounting plate fitting dimensions

107 1071

1 = Base plate

2-leaf installation with intermediate cover with divided or continuous cover

130

Y 2 = 7

2 +

AV

467*

42Y 1 =

16

+ A

V

1010

3022

50 50

50

30

50

2 2

1

Page 63: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

63

Automatic swing door systems

GEZE POWERTURN

Swing door systems

Door leaf installation with roller guide rail on the hinge side, 1-leaf and 2-leafDrawing no. 70109-ep03

* = Important functional dimensionAV = Spindle extension1 = Base upper edge of door2 = Space needed for sensor strips

3 3

A B

A = DIN leftB = DIN right1 = Dimensional reference centre of hinge / upper edge of door2 = Orientation arrow for precise positioning of the mounting plate3 = Hinge size

Mounting plate fitting dimensions

13030

7*

46

1010

2242X 1 =

16

+ A

V

50 50

50 50

2 2

1

X 2=92

+AV

Page 64: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

64

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Door leaf installation with roller guide rail on the opposite hinge side, 1-leaf and 2-leafDrawing no. 70109-ep04

* = Important functional dimensionAV = Spindle extension1 = Base lower edge of lintel2 = Space needed for sensor strips

3 3

A B

A = DIN leftB = DIN right1 = Dimensional reference centre of hinge / lower edge of frame2 = Orientation arrow for precise positioning of the mounting plate3 = Hinge size

Mounting plate fitting dimensions

7*

13030

10

26

1010

2242Y 1 =

36

+ A

V

50 50

50 50

2 2

1

Y 2= 9

2+AV

Page 65: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

65

Automatic swing door systems

GEZE POWERTURN

Swing door systems

Door leaf installation with link arm on the hinge side, 1-leaf and 2-leafDrawing no. 70109-ep06

* = Important functional dimensionAV = Spindle extension1 = Base upper edge of door2 = Space needed for sensor strips

3 3

A B

A = DIN leftB = DIN right1 = Dimensional reference centre of hinge 2 = Orientation arrow for precise positioning of the mounting plate3 = Hinge size

Mounting plate fitting dimensions

X 2=92

+AV

50

X 1 = 1

6 +

AV

30

42

7*

43

1010

22

50

50 50

2

1

2

Page 66: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

66

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Transom installation with link arm on the opposite hinge side, 1-leaf and 2-leafDrawing no. 70109-ep05

* = With sensor adapter 35.5 mm** = Important functional dimensionAV = Spindle extension

4 4

30*

30*

A B

* = With sensor adapter 35.5 mmA = DIN leftB = DIN right

Mounting plate fitting dimensions

107 1071

1 = Base plate

2-leaf installation with intermediate cover with divided or continuous cover

1 = Dimensional reference centre of hinge / upper edge of door2 = Concealed cable routing possible in the hatched area, e.g. Ø 20 mm for the mains connec-

tion or low voltage connection3 = Orientation arrow for precise positioning of the mounting plate4 = Hinge size

LT = Reveal depth1 = Base lower edge of lintel2 = Space needed for sensor strips

43

42Y 1 =

16

+ AV

Y 2 = 7

2 +

AV

1010

22LT

130

50 50

30* 8*

*

50 50

1

2 2

AV = 30

Page 67: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

67

Automatic swing door systems

GEZE POWERTURN

Swing door systems

Powerturn IS/TS: transom installation with guide rail on the hinge side, 2-leafDrawing no. 70109-ep21

1 = Powerturn with roller guide rail and GC 338 sensor strip2 = TS 5000 L door closer with guide rail

Attachment of mounting plate (Powerturn) and base plate (TS 5000 L)

Dimensions roller guide rail (Powerturn), GC 338 and guide rail (TS 5000 L)

B

12.5K = B-1211107190

36

(42)

25

190

30

57

38497

422

0

0

776

745

600

590

420

410

310

300

130

120

(50)

2

1

2

1

K = Position of intermediate base plateB = Hinge clearance1 = Hinge size2 = Dimensional reference centre of hinge

2 2

1 3 3 1B-1180

190

38 675 120428.5

30** 30**

190 330 333

720 460

B = Hinge clearance** = Recommended dimensions for installation of

GC 335 and GC 338 sensor strips

22

10

(42)

1010

36

1526

67

92

70

36

130

(42)

31

19

9

36

10

70

92

2210

130

21

1 = Hinge size2 = Dimensional reference centre of

hinge3 = Lever length

Page 68: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

68

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

Powerturn IS/TS: transom installation with link arm on the opposite hinge side, 2-leafDrawing no. 70109-ep25

1 = Powerturn with link arm and GC 338 sensor strip2 = TS 4000 door closer with link arm

2

1

2

1

15154

36

(42)

190K = B-121112.5

190107

B

38 497

422

0 776

745

10600

590

420

410

310

300

130

120

50

K = Position of the intermediate base plateB = Hinge clearance1 = Hinge size2 = Dimensional reference centre of hinge

2 2

1 1

460 B-1180

190 190

44 268

30**30**

720

45222

B = Hinge clearance** = Recommended dimensions for installation of GC 335 und GC 338 sensor strips1 = Hinge size2 = Dimensional reference centre of hinge

Attachment of mounting plate (Powerturn) and base plate (TS 4000)

Dimensions link arm (Powerturn), GC 338 and link arm (TS 4000)

21

7270

8

36

46(4

2) 2210

10

30

15

83

130

10

(42)

102272

25.5 41

130

Page 69: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

69

Automatic swing door systems

GEZE POWERTURN

Swing door systems

Legend for the cable diagrams

Cable1 = NYM-J 3 x 1.5 mm2

2 = J-Y(ST)Y 1 x 2 x 0.6 LG3 = J-Y(ST)Y 2 x 2 x 0.6 LG4 = J-Y(ST)Y 4 x 2 x 0.6 LG5 = LiYY 2 x 0.25 mm2

6 = LiYY 4 x 0.25 mm2

7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2

8 = Route empty pipe with pull-wire inner diameter 10 mm

Notes • Cable diagrams can also be prepared for specific building projects after receipt of order • Version of standard cable diagrams in accordance with GEZE specifications • Cable routing according to VDE0100/ IEE regulations • Allow the cable for the drive to project at least 1500 mm out of the wall

1) Door transmission cable (included in the scope of supply for sensor strip), cable routing through a hole in the door leaf is not permitted for fire control doors.2) Cable exit for door drive, see installation drawings for Powerturn3) Cable included in the scope of supply for the sensor4) Install in the direct vicinity of the door5) Mains connection box WxHxD min. 65 x 65 x 57 with PG-11 duct, on site6) Low-voltage connection box WxHxD min. 94 x 65 x 57 with PG-11 duct, on site7) E.g. door transmission cable, 8-wire, art. no. 0669228) Branch box, on site

AbbreviationsHS = Main switchNOT = Emergency-stop switchUT = Circuit breaker CLOSE DOOR (only with F variant)KB = Contact sensor authorisedPS = Programme switchST = Emergency stopKI = Contact sensor insideKA = Contact sensor outsideTOE = Door openerRM = Bar messageRS = Smoke switch (only with F variant)RSZ = Smoke switch control unit (only with F variant)TS = Door closerMK = Magnetic contact

3)3)KA

388

3221 11 1

KB

3

KI

3

ST

3

PS

D/D*

BA

C

HS NOT UT4)

III

II

I

IV

VV

I = Feeder 230 V / 50 HzII = 10 A fuseIII = Connected value 230 W, 1 A 1-, 2-leaf with manual fixed leaf; connected value 400 W, 1 A with 2-leafIV = And / OrV = Option

B+200

B/2

B

B/2

KI

KA

max. 100

max

. 300

5)

6)

Powerturn / Powerturn F

Page 70: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

70

Automatic swing door systems

GEZE POWERTURN

GEZE AUTOMATIC DOOR SYSTEMS

1-leaf

RS 3 3RSRS 33RS

7

88

8)

C

A

B

D

C

A

B

D

3 3

6)

5)1RSZ

RMTOE

1

12

RSZ

2)

1)

8

RMTOE

2)

GC 338 GC 338

Powerturn / Powerturn F

Powerturn / Powerturn F

I II

2-leaf

8

D*83

2)2)2)

*

83

1

D

7

7

C

A

B

DC

A

B

D

6

1

6)

5)

6)

5)

RM

3

1

TOE

RSZ

RMTOE

RM

3

1

1TOE

2

RSZ

2)

1)

8

RMTOE

8)

8

8

7)

4

7

RS 3 3RSRS 3 3RS

6

GC 338 GC 338 GC 338 GC 338

III IV

III IV

Powerturn / Powerturn F

I II

Powerturn / Powerturn F Powerturn /

Powerturn FPowerturn / Powerturn F

Photo: GEZE GmbH

I   = Transom installationII  = Door leaf installationIII  = Fixed leafIV  = Active leaf

Page 71: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Accessories for swing door systems

Cover, mounting plate, link arm, roller guide rail with lever

CoverThe cover is available in an anodised or coloured finish. In the case of double-leaf versions, the cover can be ordered as a continuous variant or with intermediate cover.

Mounting plate for drives (option)A mounting plate may be necessary, depending on the installation situation. A mounting plate is generally recommended to make installation easier. A respective mounting plate is supplied according to the cover version.

Link armsare offered for different reveal depths

Roller guide rail with leverInstallation depends on the type of hinge action chosen.

Cover Mounting plate Link arm

Roller guide rail / guide rail with lever

71

Automatic swing door systems

ACCESSORIES

Swing door systems

Page 72: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

NoteMore detailed information on the following accessories can be found in the catalogue: GEZE activation devices and sensor systems

Operating automatic swing doors

Programme switches for the selection of the operating mode for automatic swing doors

GEZE offers programme switches for a wide range of individual requirements. The switches are suitable for universal use – for surface-mounted or flush-mounted installation. The following switch types are available:

Display programme switch (DPS)Key programme switch (TPS)Mechanical programme switch (MPS)

The following operating modes can be set:

“Permanently open”The door moves to the OPEN position and remains open. Movement detector or opening button are deactivated. “Night”The movement detectors are switched inactive, the door closes. The door can only be opened with contact sensor authorised (KB) or manual release. Option: The door leaves are locked electrically to prevent forced opening.

“Exit only” (One-direction operation from the inside to the outside)The door only opens and closes when someone goes out from the inside. The movement detector outside is switched inactive, the one inside is switched active.

“Automatic”The door opens as soon as it is actuated via the movement detector or keys, and closes after a certain individually adjustable time. Safety sen-sors protect the leaves’ travel path. If there is someone in the door opening, the door will not close.

“OFF” (depending on model)Drive motor, locking, activation and safety sensors are switched off, the door leaves can be moved manually.

Key switchThe programme switch can be blocked using a key switch.

Securing the programme switchesThe mechanical programme switch (MPS) is also available in a lockable version. The display programme switch (DPS) and key programme switch (TPS) can be combined with a key switch. Alternatively, the DPS and TPS programme switches can be secured using a code.

Display programme switch (DPS) Key programme switch (TPS) Mechanical programme switch (MPS)

72

Automatic swing door systems

ACCESSORIES

GEZE AUTOMATIC DOOR SYSTEMS

Page 73: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Automatic activation

Reliable activation with GEZE sensors

Radar movement detectorRadar movement detectors register all objects that move within the radar field. All movements within the radiation range are recorded as a switching pulse which is forwarded as a door opening signal. The pre-programmed convenience setting of the GEZE radar movement de-tectors ensures they can be put into operation quickly. Automatic configuration is possible via keys or a remote control. Reliable detection is achieved with a clearly defined radar field. Energy can be saved through detection of people’s direction of movement. Excessive door opening is avoided since cross-traffic can be faded out.

GEZE TSA 160 NT Z-IS and radar movement detector, Andels Hotel, Berlin, Germany (Photo: Stefan Dauth)

Radar movement detector GC 304

73

Automatic swing door systems

ACCESSORIES

Swing door systems

Page 74: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Manual activation

Push buttonsGEZE push buttons for the wireless activation of system doors – reliable, convenient and safe at the push of a button.

Capacitive push buttonThe design-oriented and sturdy LED sensor button makes intuitive and straightforward operation possible. No great efforts are required for activation – touching the button slightly is sufficient. Suitable for use both indoors and outdoors, the LED sensor button can be recognised easily in the dark thanks to the blue LED lighting. In addition, the sensor has raised Braille lettering on it. A visual signal initiates activation through the push button. The push button is waterproof, impact-resistant and vandalism-proof. This makes it very well suited for outdoor use or installation in the floor.

Proximity switchOpen doors in a flash: With GEZE infrared sensors, internal doors without precise perception requirement can be actuated cleanly and comfor-tably. Active infrared sensors ensure hygienic access to toilet facilities, for example. The risks of infection are also minimised in hotel kitchens, hospitals and doctors’ surgeries. The impulse generator is installed at hand height and precisely detects people and objects – independently of their direction of movement – both in the direct vicinity of only 5 cm as well as 0.6 m away. The different scanning ranges can be optimally adapted to existing environmental conditions and the wishes of the user groups. The non-contact sensor system provides maximum operating convenience – people only need to approach them to trigger the automatic opening mechanism. The optimum system structure permits simple and time-saving installation in the flush-mounted box.

Radio activationGEZE radio transmitters are used for wireless activation of doors and windows as a multi-channel solution. For every additional channel, an additional electrical device or function can be switched at the push of a button. Thanks to the very small size of the radio modules, radio trans-mitters can easily be integrated in the drive or in a flush-mounted box. They can also be clipped directly into the elbow switched and mounted without wires on glass.

Push button LED sensor button Proximity switch GC 306

Radio activation Plastic elbow switch Stainless steel elbow switch IP65

74

Automatic swing door systems

ACCESSORIES

GEZE AUTOMATIC DOOR SYSTEMS

Page 75: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Electronic protection

The right choice of protection The GEZE product range of safety sensors offers the right solution for every door situation and every type of use. Because the choice of safety sensors is an important factor in enabling you to operate automatic doors providing barrier-free access conveniently, reliably and economically, and to adapt their functionality to users‘ needs in the best way possible.

Sensor strips are the right choice for standard door situations with door widths up to 1200 mm and door heights up to 3500 mm. A more compact and universal design, particularly on doors with narrow frames, is achieved via the GC GR sensor roller guide rail or sensor and link arm adapter.

From a visual perspective, we recommend the combination of a GC 338 sensor on the wide door leaf and a GC 335 on the narrow double leaf on asymmetrical double-leaf door systems with passive leaf widths below 600 mm.

If an automatic door with vertical push-bars, or a door width exceeding 1200 mm is planned, the GC 342 laser scanner offers more cost-effective protection. Depending on the door configuration and door environment, it can mean a time saving of up to 50 % for the engineer with respect to installation and commissioning.

If the appearance, or protecting the cabling between the sensor and drive is important, the cable transition can be concealed on all door drives and sensors. The cable from the sensor to the drive is guided between the door leaf and the door frame.

Safety widths of swing door sensors:

300* 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600*

GC 335

GC 338

GC 342

* = min./max. door width dependent on drive

75

Automatic swing door systems

ACCESSORIES

Swing door systems

Page 76: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

GC 338 sensor strip The energy- and space-saving sensor strip GC 338 has a very large safety range and offers enhanced protection on the primary and secondary closing edges. In addition, the sensor has a wall blanking feature which makes it possible to guarantee maximum safety even with doors that open against walls. Safeguarding all GEZE swing door drives with door leaf widths of up to 1500 millimetres is achieved with only one sensor system. The GC 338 not only offers advantages for installation and commissioning – the complete door system is supplied via an interface. The sensor strip automatically adapts to its environment. This saves learning time and installation costs. The GEZE sensor strip GC 338 has the following features:

• Reliable function under all weather and floor conditions up to 3.5 m in accordance with DIN 18650 / EN 16005 • One sensor system safeguards door leaf widths of up to 1500 mm • Wall blanking: The sensor can detect a wall and blank this out automatically • Elegant roller guide rail can even be used with slim door profiles • Current consumption in operating mode: 200 mA • Quick and easy installation of the modules using the SNAP-IN mechanism, allowing modules to be positioned and fixed in the profile

without tools

GC 338 sensor strip

Frontal detection field Integrated wall blanking

The GC 342 laser scanner is generally recommended for normal protection pursuant to DIN 18650/EN 16005.

The GC 342 reduces installation and commissioning by up to 50% compared with sensor strips.

Installation on doors with vertical rod and/or door widths >1200 mm

76

Automatic swing door systems

ACCESSORIES

GEZE AUTOMATIC DOOR SYSTEMS

Page 77: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Sensor roller guide rail GC GR - the ideal combination of safety and designThe GC GR sensor roller roller guide rail is available for the complete range of Slimdrive EMD models as well as all the TSA 160 NT and Power-turn drive versions. The sensor and the roller roller guide rail can be put together in such a way that they look like a single compact and more integrated design. The features at a glance:

• Suitable for single and double-leaf swing door • Available for all TSA 160 NT, Slimdrive EMD and Powerturn variants with roller guide rail • Sensor and roller roller guide rail profile are available separately, facilitating retrofittings to existing systems • The rain cover is available as accessory

3

4

21

1 = Sensor roller guide rail2 = Sensor strip3 = End cap for sensor roller guide rail4 = End cap for sensor strip

Sensor roller guide rail GC GR

Adapter for sensor and link arm for slimdrive EMD and TSA 160 NT - Integration of link arm and sensor strips on one levelExactly similar as in case of the sensor roller guide rail GC GR, the newly introduced adapter for link arm and sensor enables an optimal ins-tallation on doors with slim frames. The link arm program of Slimdrive EMD and TSA 160 NT drives was re-worked, so that the adapter can be combined with new link arms. Advantages:

• Better integration of link arm and sensor strip GC 338, GC 335 or GC 338 into the door design • Simple installation, in particular in case of slim door frames • With the new link arms a maximum reveal depth of 400 mm can now be bridged

Adapter for sensor and link arms for Slimdrive EMD and TSA 160 NT

77

Automatic swing door systems

ACCESSORIES

Swing door systems

Page 78: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

EMD and GC GR (GC 338) transom installation with roller guide rail on the hinge sideDrawing no. 70106-ep35

EMD and GC GR (GC 338) transom installation with roller guide rail on the opposite hinge sideDrawing no. 70106-ep35

EMD

6840

34

70

50

(51.

2)(4

3.4)

75

EMD

40

50

15

68

95

(43.

4)(5

1.2)

50

70

78

Automatic swing door systems

ACCESSORIES

GEZE AUTOMATIC DOOR SYSTEMS

Page 79: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

TSA 160 NT and GC GR (GC 338) transom insatallation with roller guide rail on the hinge sideDrawing no. 70106-ep35

GC GR (GC 338) 1200 mm with roller guide rail, single leafDrawing no. 70106-ep35Note: For double-leaf doors mirror and add this view.

BA

37.5

15

( 28.6

)

15~50

30 30LL/2

~50 ~50

1717L1 /2

3030

L1

A = Hinge sideB = Opposite hinge sideL = Length

TSA160NT

684055

21

7012

0

(42)

(54)

50

79

Automatic swing door systems

ACCESSORIES

Swing door systems

Page 80: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

80

Automatic swing door systems

ACCESSORIES

GEZE AUTOMATIC DOOR SYSTEMS

Photo: GEZE GmbH

GEZE GC 342 laser scannerLaser scanner for the protection of automatic swing doors in compliance with DIN 18650/EN 16005

The compact and space-saving GEZE sensor GC 342 serves to protect automatic swing doors in compliance with DIN 18650/EN 16005. The sensor is preferred for use with difficult floor conditions (e.g. floor mats, metal runners, dark and absorbent floors). A large field of detection ensures protection of the main and secondary closing edges, with a wide recording field across the entire width of the door. The sensor also has wall blanking, guaranteeing maximum security even with doors that run against walls. The GC 342 automatically learns its environment. With just one sensor system, the safety of all GEZE swing doors drives up to door leaf widths of 1600 mm can be achieved.

Thanks to the integrated wall blanking, the sensor learns its permanently installed environment – walls, radiators, windowsills. The parameter adjustment of the wall blanking in the drive can be omitted. The installation on the upper edge of the door near the hinge is cleverly solved and therefore is quick and easy to achieve. The door leaf width to be locked is learned using hand movements. Settings such as the position of the master module on the hinge side/opposite hinge side, immunity, background monitoring and monitoring of the secondary closing edge can be handled easily using dip switches.

Page 81: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Service Tools

GEZEconnectsBluetooth is an internationally standardised short-distance radio signal with a range of up to ten metres. The software GEZEconnects makes wireless connection via Bluetooth possible between a computer and the automatic door systems from GEZE. All door system settings can be carried out via an intuitive graphic interface, stored, sent by e-mail and transferred to a word processing programme as a protocol. Diagnosis functions show the most important function parameters of the door system in real time, so that problems are recognised at a glance and can be eliminated. All the pre-settings can be taken over very easily for further door systems. The convenient documentation of initial operation, servicing and diagnosis protocols as well as all statistical data can be downloaded at any time. Password protection to freeze operating para-meters and servicing data guarantees there will be no unauthorised modifications made.

Service terminal ST 220Mobile, handy and straightforward – that is the parameter setting for the automatic GEZE door systems using the service terminal ST 220. Communication and data exchange between the service terminal and the door drive is via an integrated RS485 interface. The large illuminated display is easy to operate thanks to the plain text display. The service terminal is equipped with a readout function for servicing and diagnosis work. Power is supplied via the door system. Password protection to freeze operating parameters and servicing data guarantees there will be no unauthorised modifications made.

A service adapter for the ST 220 which is available separately can be laterally inserted from the outside into the drive, allowing operating para-meters and service data to be read out and parameters to be set without the drive cover having to be removed.

Notes• GEZE service tools are available for the Slimdrive EMD, TSA 160 NT and Powerturn range of drives.• Parameters of GEZE drives may only be changed by technicians trained in accordance with DIN 18650/EN 16005 and authorized by the

manufacturer (GEZE).

B E W E G U N G M I T S Y S T E M

GEZEconnects I SOFTW AREzur kabellosen Verbindung von GEZE Automatischen Türsystemen und PCs über Bluetooth

GEZ

Eco

nn

ects

I S

OFT

WA

RE

GEZE GmbHReinhold-Vöster-Str. 21-2971229 Leonberg Germany

Telefon: +49 (0)7152-203-0Telefax: +49 (0)7152-203-310

www.geze.com

Systemvoraussetzungen:

PC mit Windows XPIntel oder 100% kompatiblen Prozessor500 MB RAM1,5 GHzCD LaufwerkBluetooth Schnittstelle150 MB freier Speicherplatz

TÜRTECHNIK

AUTOMATISCHE TÜRSYSTEME

RWA UND LÜFTUNGSTECHNIK

SICHERHEITSTECHNIK

GLASSYSTEME Id.Nr. 134995 · Version 090518 · Änderungen vorbehalten

GEZEconnects I SOFTW AREzur kabellosen Verbindung von GEZE Automatischen Türsystemen und PCs über Bluetooth

B E W E G U N G M I T S Y S T E M

GEZEconnects Service terminal ST 220

81

Automatic swing door systems

ACCESSORIES

Swing door systems

Service adapter for ST 220

Bluetooth service adapter for ST 220

Page 82: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

82 GEZE AUTOMATIC DOOR SYSTEMS

Innovative system solutions

POTENTIAL APPLICATIONS OF GEZE PRODUCTS

01

04

06

07

20 07

10

08

11

13

11

22

17

06

02

14

You will find more product information in the relevant brochures, see ID numbers.

Door technology

01 Overhead door closersID 091593, ID 091594

02 Hold-open systemsID 091593, ID 091594

03 Integrated door closers ID 091609

04 Floor springs and all-glass fittingsID 091607

05 Sliding fitting systems and linear guidesID 123605, ID 000586

Automatic door systems

06 Swing doorsID 144785

07 Sliding, telescopic and folding doorsID 143639

08 Curved sliding doorsID 135772

09 Revolving doorsID 132050

10 Activation devices and sensorsID 142655

Smoke and heat extraction and window technology

11 Fanlight opening systemsID 127787

12 Electric opening and locking systemsID 127785, ID 127789

13 Electrical spindle and linear drivesID 127785, ID 127789

14 Electric chain drivesID 127785, ID 127789

15 Smoke and heat extraction systemsID 127785, ID 139075

Safety technology

16 Emergency exit systemsID 132408

17 Access control systemsID 132158

18 Panic locksID 132848

19 Electric strikesID 148666

20 Building management systemID 132408

Glass systems

21 Manual sliding wall systems (MSW)ID 104377

22 Integrated all-glass systems (IGG)ID 104366

04

Page 83: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

83Swing door systems

Innovative system solutions

POTENTIAL APPLICATIONS OF GEZE PRODUCTS

21

18

03

05

09

16

19

12

15

21

15 17

Door technology

The functionality, superior performance and reliability of GEZE door closers are impressive. A common design across the range, the ability to use them on all common door leaf widths and weights, and the fact that they can be individu-ally adjusted makes their selection simple. They are con-tinually being improved and enhanced with up-to-date fea-tures. For example, the requirements of fire protection and accessibility are fulfilled with a door closer system.

Automatic door systems

GEZE automatic door systems open up a huge variety of options in door design. The latest, innovative high-per-formance drive technology, safety, ease of accessibility and first class universal drive design set them apart. GEZE offers complete solutions for individual requirements. A dedicated division is responsible for the development and construction of individual special designs.

Smoke and heat extraction and window technology

GEZE smoke and heat extraction systems and ventilation technology provide complete systems solutions combin-ing the many requirements of different types of windows. We supply a full range from energy efficient drive systems to natural ventilation and complete solutions for supplying and extracting air, also as certified SHEVs.

Safety technology

GEZE safety technology sets the standards where preven-tative fire protection, access control and anti-theft security in emergency exits are concerned. For each of these objec-tives GEZE offers tailored solutions, which combine the in-dividual safety requirements in one intelligent system and close doors and windows in case of danger in a coordinated manner.

Building systems

In GEZE’s Building Management System GEZE door, win-dow and safety products can be integrated in to the se-curity and control systems of the building. A central con-trol and visualisation system monitors various automation components in the building and offers security through many different networking capabilities.

Glass systems

GEZE glass systems stand for open and transparent interior design. They can either blend discreetly into the architec-ture of the building or stand out as an accentuated feature. GEZE offers a wide variety of technologies for functional, reliable and aesthetic sliding wall or sliding door systems providing security with lots of design scope.

Page 84: GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ...€¦ · GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER FREE ACCESS. GEZE AUTOMATIC DOOR SYSTEMS BEWEGUNG MIT SYSTEM

G E Z E AU TO M AT I C D O O R S YS T E M S

G E Z E R E P R E S E N TAT I V E

Id.No. 144785 · Vers. EN 1902 · Subject to change without notice

GEZE GmbHP.O. Box 136371226 LeonbergGermany

GEZE GmbHReinhold-Vöster-Straße 21-2971229 LeonbergGermanyTel. +49 7152 203 0Fax +49 7152 203 310www.geze.com

GermanyGEZE GmbHNiederlassung Süd-WestBreitwiesenstraße 871229 LeonbergTel. +49 7152 203 594Fax +49 7152 203 [email protected]

GEZE GmbHNiederlassung Süd-OstParkring 1785748 Garching bei MünchenTel. +49 7152 203 6440Fax +49 7152 203 [email protected]

GEZE GmbHNiederlassung OstAlbert-Einstein-Ring 514532 Kleinmachnow bei BerlinTel. +49 7152 203 6840Fax +49 7152 203 [email protected]

GEZE GmbHNiederlassung Mitte/LuxemburgSiemensstraße 1463263 Neu-IsenburgTel. +49 7152 203 6888Fax +49 7152 203 [email protected]

GEZE GmbHNiederlassung WestHeltorfer Straße 1240472 DüsseldorfTel. +49 7152 203 6770Fax +49 7152 203 [email protected]

GEZE GmbHNiederlassung NordAlbert-Schweitzer-Ring 24-26 (3. OG)22045 HamburgTel. +49 7152 203 6600Fax +49 7152 203 [email protected]

GEZE Service GmbH Niederlassung Süd-WestReinhold-Vöster-Straße 2571229 LeonbergTel. +49 1802 923392Fax +49 7152 9233 [email protected]

GEZE Service GmbH Niederlassung SüdParkring 1785748 Garching bei MünchenTel. +49 1802 923392Fax +49 7152 9233 [email protected]

GEZE Service GmbH Niederlassung Mitte/LuxemburgSiemensstraße 1463263 Neu-IsenburgTel. +49 1802 923392Fax +49 7152 9233 [email protected]

GEZE Service GmbH Niederlassung WestHeltorfer Straße 1240472 DüsseldorfTel. +49 1802 923392Fax +49 7152 9233 [email protected]

GEZE Service GmbH Niederlassung OstAlbert-Einstein-Ring 514532 Kleinmachnow bei BerlinTel. +49 1802 923392Fax +49 7152 9233 [email protected]

GEZE Service GmbHNiederlassung NordAlbert-Schweitzer-Ring 24-26 (3. OG)22045 HamburgTel. +49 1802 923392Fax +49 7152 9233 [email protected]

AustriaGEZE AustriaWiener Bundesstrasse 85A-5300 HallwangTel: +43 6225 87180Fax +43 6225 87180 [email protected]

Baltic States – Lithuania / Latvia / EstoniaTel. +371 678960 [email protected]

BeneluxGEZE Benelux B.V.Industrieterrein KapelbeemdSteenoven 36 5626 DK EindhovenTel. +31 4026290 80Fax +31 4026290 [email protected]

BulgariaGEZE Bulgaria - Trade Representative OfficeNickolay Haitov 34 str., fl. 11172 SofiaTel. +359 247043 73 Fax +359 247062 [email protected]

ItalyGEZE Italia S.r.lSede di VimercateVia Fiorbellina 20 20871 Vimercate (MB) Tel. +39 0399530401 Fax +39 039 9530459/[email protected]

Sede di RomaVia Lucrezia Romana, 9100178 RomaTel. +39 039 9530401Fax +39 039 [email protected]

KoreaGEZE Korea Ltd.T4-716 Western Tower, 24 Jeong-balsanro, Ilsangu Goyangsi, Gyeonggido, 10403, South KoreaTel. +82 31 814 6410Fax +82 31 814 [email protected]

PolandGEZE Polska Sp. z o.o.ul. Marywilska 24 03-228 WarszawaTel. +48 224 404 440Fax +48 224 404 [email protected]

RomaniaGEZE Romania S.R.L.IRIDE Business Park,Str. Dimitrie Pompeiu nr. 9-9a,Building 10, Level 2, Sector 2,020335 BucharestTel. +40 212507 750Fax +40 316201 [email protected]

RussiaOOO GEZE RUSLetnikovskaya str. 10/2Floor 6, room VII115114 MoscowTel. +7 495 741 40 [email protected]

Scandinavia – SwedenGEZE Scandinavia ABMallslingan 10Box 706018711 Täby, SwedenTel. +46 87323 400Fax +46 87323 [email protected]

Scandinavia – NorwayGEZE Scandinavia AB avd. NorgeIndustriveien 34 B2073 DalTel. +47 63957 200Fax +47 63957 [email protected]

Scandinavia – DenmarkGEZE DanmarkBranch office of GEZE Scandinavia AB Mårkærvej 13 L2630 TaastrupTel. +45 463233 [email protected]

SingaporeGEZE (Asia Pacific) Pte. Ltd.21 Bukit Batok Crescent #23-75 Wcega TowerSingapore 658065Tel. +65 6846 1338Fax +65 6846 [email protected]

South AfricaGeze South Africa (Pty) Ltd.GEZE, Building 3, 1019 Morkels CloseMidrand 1685Tel. + 87 94337 88Fax + 86 66137 [email protected]

SwitzerlandGEZE Schweiz AGZelglimatte 1A6260 ReidenTel. +41 62 28554 00Fax +41 62 28554 [email protected]

TurkeyGEZE Kapı ve Pencere SistemleriSan. ve Tic. Ltd. Sti.İstanbul Anadolu Yakası OrganızeSanayı BolgesiGazi Bulvari Caddesi 8.Sokak No:8 Tuzla-IstanbulTel. + 90 216 45543 15Fax + 90 216 45582 [email protected]

UkraineGEZE Ukraine LLC45, Elektrotekchnicheskaya str.,Kiev, 02222Tel./Fax +38 [email protected]

United Arab Emirates/GCCGEZE Middle EastP.O. Box 17903Jebel Ali Free Zone DubaiTel. +971 48833 112Fax +971 48833 [email protected]

United KingdomGEZE UK Ltd.Blenheim WayFradley ParkLichfieldStaffordshire WS13 8SYTel. +44 15434430 00Fax +44 15434430 [email protected]

ChinaGEZE Industries (Tianjin) Co., Ltd.Shuangchenzhong RoadBeichen Economic DevelopmentArea (BEDA)Tianjin 300400, P.R. ChinaTel. +86 22 26973995Fax +86 22 [email protected]

GEZE Industries (Tianjin) Co., Ltd.Branch Office ShanghaiJia Little Exhibition CenterRoom C 2-102Shenzhuan Rd. 6000201619 Shanghai, P.R. ChinaTel. +86 21 52340960Fax +86 21 [email protected]

GEZE Industries (Tianjin) Co., Ltd.Branch Office GuangzhouRoom 17 C 3Everbright Bank Building, No.689Tian He Bei Road510630 Guangzhou, P.R. ChinaTel. +86 20 38731842Fax +86 20 [email protected]

GEZE Industries (Tianjin) Co., LtdBranch Office BeijingRoom 04-05, 7th Floor Red Sandalwood Plaza No. 27 Jianguo Road Chaoyang District 100024 Beijing, P.R.China Tel. +86 10 85756009Fax +86 10 [email protected]

FranceGEZE France S.A.R.L.ZAC de l’Orme RondRN 1977170 ServonTel. +33 1 606260 70Fax +33 1 606260 [email protected]

HungaryGEZE Hungary Kft.Hungary-2051 BiatorbágyVendel ParkHuber u. 1.Tel. +36 23532 735Fax +36 23532 [email protected]

IberiaGEZE Iberia S.R.L.C/ Andorra 2408830 Sant Boi de Llobregat (Barcelona)Tel. +34 902194 036Fax +34 902194 [email protected]

IndiaGEZE India Private Ltd.MF 2 & 3, Guindy Industrial EstateEkkattuthangalChennai 600 097TamilnaduTel. +91 44 406169 00Fax +91 44 406169 [email protected]