2
R e v o l u t i o n i  z i  n g  t h e  P  u m  p i  n  g  I  n d  u  s  t  r   y  Geyser Pump Tech, LLC P .O. Box 3402, Dublin, OH 43016-0196 Phone (614) 398-0960 & (541) 953-3092  www.Envirocern.com The Geyser Hybrid Pump has been developed to provide clog free pumping operation for high grit solids removal using less energy  with easy control of the pumping rate.  Air supply f or Geyser Pump Mod e Clean-out Discharge pipe / Grit ejection Flow velocity is 18 ft/sec.  Water an d Grit Suction Port Flange  Air supply f or Airlift Pum p Mode 1  Air supply fo r  Airlift Pump M ode 2  Airlift Pump M ode  Air Accumulat or the GHP Design Discharge pipe diameter 2” 3” 4” 12” Overall height 1’ 10” 2’10” 3’2” 3’11” Overall diameter (does not include intake screens)  10” 12 16” 2’6”  Weight (lb) 30 40 50 100  Air sup ply (3) 1/2” 1” 1 1/4” 2” Typical pumping rate (gpm) 28 64 86 1,200 Materials: PVC standard (Max. operational pressure 40 psig), Powder coated mild steel and stainless steel *(note) Proper pumping rate selected based on submergence, lift, application and gpm required.  Specifications (GHP) Geyser Hybrid Pump (GHP) Low Cost, Low Energy for Grit Removal (Patent Pending) Lift Pipe Diameters 2”, 3“, 4” , 12” Lifting Height 1.5 x Submergence Grit Diameter 0 - 24mm Grit Flow Velocity 18 ft per second

Geyser Hybrid Pumps

Embed Size (px)

Citation preview

8/12/2019 Geyser Hybrid Pumps

http://slidepdf.com/reader/full/geyser-hybrid-pumps 1/2

8/12/2019 Geyser Hybrid Pumps

http://slidepdf.com/reader/full/geyser-hybrid-pumps 2/2

R e v o l u t i o n i z i n g t h e P u m p i n g I n d u s t r y

Geyser Pump Tech, LLC P.O. Box 3402, Dublin, OH 43016-0196 Phone (614) 398-0960 & (541) 953-3092 www.Envirocern.com

Geyser Hybrid Pump (GHP)Low Cost, Low Energy for Grit Removal(Patent Pending)

Operating pressure = [Submergence (ft) + GEP height (ft)] x 0.43 (psi/ft)] Air flow [DCFM] = # [pulses/min] x Delivered air volume to GEP [ft3/pulse] Air flow [SCFM] = [Operating pressure (psi) + 14.7 (psi)]/14.7 (psi) x Air flow [DCFM]Flow rate:# pulses/min x gallon/pulse = flow (gpm)

Delivered Air Flow to GHP [ft3 / pulse]

Delivered Liquid and Grit to GHP [gallon / pulse]

Radii of InfluenceRadii of Influence

Typical Grit Pit Placement

Design Criteria

2”GHP 3”GHP 4”GHP 12”GHP

0.13 0.35 0.52 6.12

2”GHP 3”GHP 4”GHP 12”GHP1.1 2.4 4.3 38.9

Pumping rate Velocity Air flow Power of Blower Max Grit size4" Geyser Hybrid Pump 35 GPM 18 ft/sec 20 SCFM @ 3.5 psig 0.8 BHP 24.0 mm

4" Airlift Pump 35 GPM 0.89 ft/sec 44 SCFM @ 3.5 psig 1.4 BHP 2.5 mm

WL

Submergence = 8 feet, Lift = 7 feet

Performance comparison of Airlift Pump versus GHP