GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master controller) and S 7000 (slave controller) control units are used to connect and control the GAT NET. Lock 7000 electronic locker locks from GANTNER. The control units operate in online mode and communicate with a host PC/server. The GAT NET.Controller M 7000 master controller serves as the communication bridge between the host PC/server and the GAT NET. Controller S 7000 slave controllers. For system flexibility, different slave controllers are available to suit the leading RFID technologies (see order information). Functional description The correct type of slave controller must be used to suit the RFID technology in operation. The slave controllers are connected to the master controllers via a serial RS 485 interface. Each master controller can control up to 8 slave controllers and 192 locks over a maximum cable length of 200 m. For smaller MIFARE ® /ISO systems, a light version of the slave and master controllers is available (see functionality table). In online operation, the slave controllers receive data carrier information via the connected locks. This information is sent via the master controller to the PC/server for authorization. The current status of the locker system is also forwarded to the PC/server, thereby allowing the status of each locker to be visualized using, for example, GANTNER PC software. An emergency mode function for online mode ensures operation continues if communication to the PC/server is temporarily interrupted. Highlights • Connection of locks via industry-standard MOLEX plugs • LED status display • Simple configuration with GANTNER software tools • Firmware update via host interface possible • Diagnostic system for detecting lock problems • Integration into alarm system (locker break-in alarm) Accessories Description Part No. GAT NET.Controller M 7000 Master controller for max. 8 GAT NET.Controller S 7000 slave controllers 253224 GAT NET.Controller M 7000 Light Master controller for max. 3 GAT NET.Controller S 7000 slave controllers, no relays and no optocouplers 978541 GAT NET.Controller M 7000 Light ext. GAT NET.Controller M 7000 Light extension license for max. 8 GAT NET.Controller S 7000 slave controllers 978440 GAT NET.Controller S 7000 F/ISO MIFARE ® /ISO 15693 slave control unit for max. 24 GAT NET.Lock 7000 electronic locks 253426 GAT NET.Controller S 7000 F/ISO Light MIFARE ® /ISO 15693 slave control unit for max. 12 GAT NET.Lock 7000 electronic locks 429730 GAT NET.Controller S 7000 B LEGIC ® slave controller for max. 24 GAT NET.Lock 7000 253325 GAT NET.Controller S 7000 ICLS iCLASS ® slave control unit for max. 24 GAT NET.Lock 7000 768538 1 www.gantner.com Description Part No. GAT NET.Lock 7000 Electronic locker lock 368534 GAT NET.Lock Cable 5m 5 m connection cable for the GAT NET.Lock 7000, 4-pin MOLEX plug on both ends 734430 GAT NET.Lock Cable Extension 3m 3 m extension cable for the GAT NET.Lock 7000 810021 GAT NET.Power Supply 230V Power supply unit 369434 GAT NET.Power Cord xxx Power cord for power supply unit. 494181 (EU), 494282 (UK), 511474 (AUS), 636835 (US), 636734 (IND) See description GAT NET.Power Plug Plug to forward the power supply 370426 GAT Patch Kabel 5805 5 m, shielded Ethernet patch cable with 8-pin RJ45 plugs 909321 Valid from September 15 th 2015 • Technical data subject to modification without notice! DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835 GAT NET.Controller M 7000 GAT NET.Controller S 7000 Order information Master Standard Master Light Slave Standard Slave Light Number of relays 4 0 - - Number of optocouplers 4 0 - - Max. no. of slave units 8 3* - - Max. no. of NET.Locks 192 (via slaves) 36 (via slaves) 24 12 Controller functionality table (F/ISO) *expandable to 8 with additional license (Part No. 978440)

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 · GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master

Embed Size (px)

Citation preview

Page 1: GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 · GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master

GAT NET.Controller 7000Control unit for the GAT NET.Lock 7000

ApplicationThe GAT NET.Controller M 7000 (master controller) and S 7000 (slave

controller) control units are used to connect and control the GAT NET.

Lock 7000 electronic locker locks from GANTNER.

The control units operate in online mode and communicate with a host

PC/server. The GAT NET.Controller M 7000 master controller serves as

the communication bridge between the host PC/server and the GAT NET.

Controller S 7000 slave controllers.

For system flexibility, different slave controllers are available to suit the

leading RFID technologies (see order information).

Functional descriptionThe correct type of slave controller must be used to suit the RFID technology

in operation. The slave controllers are connected to the master controllers

via a serial RS 485 interface. Each master controller can control up to 8

slave controllers and 192 locks over a maximum cable length of 200 m.

For smaller MIFARE®/ISO systems, a light version of the slave and master

controllers is available (see functionality table).

In online operation, the slave controllers receive data carrier information

via the connected locks. This information is sent via the master controller

to the PC/server for authorization. The current status of the locker system

is also forwarded to the PC/server, thereby allowing the status of each

locker to be visualized using, for example, GANTNER PC software. An

emergency mode function for online mode ensures operation continues if

communication to the PC/server is temporarily interrupted.

Highlights• Connection of locks via industry-standard MOLEX plugs

• LED status display

• Simple configuration with GANTNER software tools

• Firmware update via host interface possible

• Diagnostic system for detecting lock problems

• Integration into alarm system (locker break-in alarm)

Accessories

Description Part No.

GAT NET.Controller M 7000Master controller for max. 8 GAT NET.Controller S 7000 slave controllers

253224

GAT NET.Controller M 7000 LightMaster controller for max. 3 GAT NET.Controller S 7000 slave controllers, no relays and no optocouplers

978541

GAT NET.Controller M 7000 Light ext.GAT NET.Controller M 7000 Light extension license for max. 8 GAT NET.Controller S 7000 slave controllers

978440

GAT NET.Controller S 7000 F/ISOMIFARE®/ISO 15693 slave control unit for max. 24 GAT NET.Lock 7000 electronic locks

253426

GAT NET.Controller S 7000 F/ISO LightMIFARE®/ISO 15693 slave control unit for max. 12 GAT NET.Lock 7000 electronic locks

429730

GAT NET.Controller S 7000 BLEGIC® slave controller for max. 24 GAT NET.Lock 7000

253325

GAT NET.Controller S 7000 ICLSiCLASS® slave control unit for max. 24 GAT NET.Lock 7000

768538

1www.gantner.com

Description Part No.

GAT NET.Lock 7000Electronic locker lock

368534

GAT NET.Lock Cable 5m

5 m connection cable for the GAT NET.Lock 7000, 4-pin

MOLEX plug on both ends

734430

GAT NET.Lock Cable Extension 3m

3 m extension cable for the GAT NET.Lock 7000

810021

GAT NET.Power Supply 230VPower supply unit

369434

GAT NET.Power Cord xxx

Power cord for power supply unit. 494181 (EU), 494282

(UK), 511474 (AUS), 636835 (US), 636734 (IND)

See

description

GAT NET.Power PlugPlug to forward the power supply

370426

GAT Patch Kabel 58055 m, shielded Ethernet patch cable with 8-pin RJ45 plugs

909321

Valid from September 15th 2015 • Technical data subject to modification without notice! DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835

GAT NET.Controller M 7000

GAT NET.Controller S 7000

Order information

Master Standard

Master Light

SlaveStandard

SlaveLight

Number of relays

4 0 - -

Number of optocouplers

4 0 - -

Max. no. of slave units

8 3* - -

Max. no. of NET.Locks

192(via slaves)

36(via slaves)

24 12

Controller functionality table (F/ISO)

*expandable to 8 with additional license (Part No. 978440)

Page 2: GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 · GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master

Nominal voltage UDC: 24 V

Power supply unit: External power supply units available (see order information)

Reader types of slave control lers - GAT NET.Controller S 7000 F/ISO: - GAT NET.Controller S 7000 B: - GAT NET.Controller S 7000 ICLS:

MIFARE® + ISO 15693LEGIC® (Advant)HID iCLASS®

Maximum locks per slave controller:

- Slave standard: 24- Slave light: 12

Maximum slave controllers per master controller:

- Master standard: 8- Master light: 3*

Memory (Master): Internal memory for 10,000 bookingsSD card slot for memory expansion, log files, firmware update or user lists

Digital inputs (master controller): - Master standard: 4- Master light: 0

Digital outputs (master contr.): - Master standard: 4- Master light: 0

Interface to the locks: 1 Wire (special cable for supply and data signal)

Interface betw. slave and master: RS 485

Master and server: Ethernet

Connectors: - Master to server (Ethernet): RJ 45- Slave to master (RS 485): RJ 45- Locks: MOLEX, type Micro-Fit 3.0TM

- Supply: MOLEX

Housing material: Plastic (ABS - V0)

Dimensions: 310 mm x 133 mm x 42 mm(12.2´´ x 5.24´´ x 1.65´´)

Permitted ambient temperature: 0 °C to +60 °C

Protection type: IP 40

Protection class: I

Weight: Approx. 600 g

Environment classbased on VdS 2110: II (conditions in indoor areas)

2 www.gantner.com

Technical data

1. GAT NET.Controller M/S 7000 (same housing for master and slave)

2. SD card slot

3. Ethernet interface for PC/server connection

4. Relay outputs

5. DC 24 V output

6. Digital optocoupler inputs

7. Power supply input (DC 24 V)

8. RS 485 in-/output (for master / slave controller connection)

9. MODE and RESET buttons and status LEDs

10. GAT NET.Lock 7000 connection sockets

Dimensions

Typical application

Valid from September 15th 2015 • Technical data subject to modification without notice! DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835

310.0 mm (12.2”)

13

3.0

mm

(5

.24

”)

42

.0 m

m (

1.6

5”)

1

2

7

8

9

346 5

42

.0 m

m (

1.6

5”)

10

GAT NET.Controller M 7000

GAT NET.Controller S 7000

to the server/host Ethernet

OUT

OUT

IN

OUT

PowerPlug

IN

GAT NET.Controller S 7000 GAT NET.Controller S 7000

RS 485

RS 485 + power

Lockers

Supply

GAT NET.Lock 7000

Supply

Master ControllerGAT NET.Controller M 7000

OUT

OUT

IN

GAT NET.Controller S 7000

RS 485

RS 485 + power

Supply

Supply

Master ControllerGAT NET.Controller M 7000

Identification with RFID data carrier

42

.0 m

m (

1.6

5”)

23

42

.0 m

m (

1.6

5”)

10

GAT NET.Controller M 7000 Light

GAT NET.Controller S 7000 Light

*expandable to 8 with additional license (Part No. 978440)

Page 3: GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 · GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master

3www.gantner.comValid from September 15th 2015 • Technical data subject to modification without notice!

DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835

InstallationThe GAT NET.Controller 7000 master and slave controllers must be installed

in the vicinity of the connected GAT NET.Lock 7000 locks to keep cable

lengths to a minimum. Usually the controllers are stored on top of the

lockers.

Although the permanent fixing of the controllers is not required, when a

controller is to be permanently mounted, e.g., on a wall, use the 3 screw

holes provided in the base of the controller. The housing does not have to

be opened for this process.

Measurements for installation

Installation process

1. Drill three mounting holes based on the measurements in the diagram

above. Depending on the supporting surface, use the appropriate drill

diameter for the screws and/or wall plugs (screws to max. M4).

2. Screw in the top two screws approximately half way.

3. Mount the controller housing on the top screws and push down until

the housing stops against the screws. Tighten screws if necessary.

4. Screw the third screw into the bottom mounting hole and tighten firmly.

5. Ensure the controller is secured firmly and cannot be removed.

1. 2. 3.

1. 2.

13

3 m

m (

5.2

4´´)

5.5

mm

(0

,22

´´)

309.6 mm (12.19´´)

154.8 mm (6.09´´) 154.8 mm (6.09´´)

270.5 mm (10.65´´)

0.5

mm

(0

.02

´´)

Ø 4.8 mm (0.19´´)

4.8 mm (0.19”)

4.8 mm (0.19”)

Page 4: GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 · GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master

Electrical connections - GAT NET.Controller S 7000

GAT NET.Lock 7000 connections

Power and network connections

GAT NET.Lock 7000 connections

The locks are connected using a GAT NET.Lock Cable 5m (Part No.

734430). The 5 m cable can be extended using the GAT NET.Lock Cable

Extension 3m (Part No. 810021) or to max. 10 m using the GAT NET.

Lock Connector (Part No. 442123) and another GAT NET.Lock Cable 5m.

The numbers on the GAT NET.Controller S 7000 determine the channel

assignment for the locks.

The GAT NET.Lock 7000 locks must not be connected to the GAT

SMART.Controller S 7000!

Network connections

- RS 485 bus connection to slave controllers via RJ 45 jacks.

On the GAT NET.Controller S 7000, connect the incoming RS 485 line

(server/master side) to the “RS 485 IN“ socket and the outgoing RS 485

line (to next slave controller) to the “RS 485 OUT“ socket.

Recommended cabling

RS 485: min. CAT 5 (STP), 200 m maximum cable length per line.

LED signaling

- RS 485 IN (yellow): Connection to the master controller

- RS 485 IN (green): RS 485 communication active

- LED 1 (blue): Lock action

- LED 2 (green/red): Status information (see manual)

Reset and mode buttons

- RESET: 1. Reset of controller (see manual)

2. Delete configuration = reset to default (see manual)

- MODE: Perform automatic antenna adjustment (see manual)

Power supply

Power is connected to the MOLEX

socket labeled “Power“. Use the supplied

power supply unit (see technical data).

There are two possibilities for power supply:

1. A power supply is connected to every GAT NET.Controller S 7000 in a

RS 485 line.

2. A power supply is connected to a few controllers that forward power on

to the remaining controllers in the RS 485 line. For the controllers that

are not directly supplied, a power plug (see order information) must be

plugged into the “Power“ socket.

Note: A power supply must always be connected to the first slave

controller. If five or more slave controllers are used, the fifth

controller must also be supplied in addition to the first controller.

Power for the RS 485 line must be forwarded in the correct

direction. Use the „RS 485 OUT“ socket to continue supply to

the next controller as shown above.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

ww

w.g

antn

er.c

om

to the GAT NET.Lock 7000 locks

GAT NET.Controller S 7000

Note: The GAT NET.Controller S 7000 F/ISO Light has 12 lock connection ports

RS 485IN

RESE

T

MO

DE

LED

1

LED

2

RS 485OUT

Power

To the next GAT NET.Controller S 7000

Power supply GAT NET.Power Supply(or power plug - see description below)

From master controller or fromprevious GAT NET.Controller S 7000

GAT NET.Controller S 7000

RS 485IN

RESE

T

MO

DE

LED

1

LED

2

RS 485OUT

Power

RS 485IN

yellow green

RESE

T

MO

DE

LED

1

LED

2

RS 485OUT

Power

OUT

IN

OUT

IN

RS 485

RS 485

From master controller

Supply

Supply

OUT

INGAT NET.Controller S 7000

PowerPlug

4 www.gantner.comValid from September 15th 2015 • Technical data subject to modification without notice! DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835

Page 5: GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 · GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The GAT NET.Controller M 7000 (master

Electrical connections - GAT NET.Controller M 7000

Ethernet connection (to host)

Network connections

- Ethernet to host via RJ 45 jacks.

- RS 485 bus connection to slave controllers via RJ 45 jacks.

- 200 m max. cable length per RS 485 line.

The GAT NET.Controller S 7000 must be connected to the

“RS 485 SLAVES“ socket!

Recommended cabling

Ethernet: min. CAT 5 (STP)

RS 485: min. CAT 5 (STP), 200 m max. cable length per RS 485 line.

LED signaling

- RS 485 IN (yellow): Connection to the slave controller

- RS 485 IN (green): RS 485 communication active

- LED 1 (blue): For future use

- LED 2 (green/red): Status information (see manual)

Reset and mode buttons

- RESET: 1. Reset of controller (see manual)

2. Delete configuration = reset to default (see manual)

- MODE: Reserved for future use

Power supply

Power is connected to the MOLEX

socket labeled “Power“. Use the supplied

power supply unit (see technical data).

Note: For a tidy installation, the power supply can be stored in the

designated slot in the bottom of the controller housing.

GAT NET.Controller M 7000

Ethernet to host

Note: The GAT.NET Controller M 7000 F/ISO Light does not have any relays or optocouplers

RS 485SLAVES

RESE

T

MO

DE

LED

1

LED

2

RS 485ADD-ON

Power

To the first GAT NET.Controller S 7000

Power supply GAT NET.Power Supply(or power plug - see description below)

GAT NET.Controller M 7000

Power and slave controller connections

RS 485SLAVES

yellow green

RESE

T

MO

DE

LED

1

LED

2

RS 485ADD-ON

Power

RS 485IN

RESE

T

MO

DE

LED

1

LED

2

RS 485OUT

Power

Safety instructions

- This device must be installed by qualified personnel only.

- The applicable safety and accident prevention regulations

must be observed.

- Safety devices must not be removed.

- Please observe the technical data of the device specified

on the data sheet.

- The device must be disconnected from the power supply

prior to installation, assembly or dismantling.

The WEEE symbol on GANTNER products and their packaging

indicates that the corresponding material must not be disposed

of with normal household waste. Instead such marked waste

equipment must be disposed of by handing it over to a designated

electronic waste recycling facility. Separating and recycling this

waste equipment at the time of disposal will help to conserve

natural resources and ensure that it is recycled in a manner that

protects human health and the environment. Please contact your

local authority for further details of your nearest electronic waste

recycling facility.

5www.gantner.comValid from September 15th 2015 • Technical data subject to modification without notice!

DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835