29
Gas Absorption Heat Pumps Mark Wilson National Product Manager Technical Seminar 2014

Gas absorption heat pumps

  • Upload
    buingoc

  • View
    226

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Gas absorption heat pumps

Gas Absorption Heat Pumps

Mark WilsonNational Product Manager

Technical Seminar 2014 

Page 2: Gas absorption heat pumps

• History• Absorption Technology• Key features and benefits• Other products• Case studies

Contents

Page 3: Gas absorption heat pumps

Development of Gas Absorption Heat Pumps

1920s: Albert Einstein does work on domestic refrigerators for the Servel company

1950s: and 60s4 million refrigerators 

sold

1968: First commercial gas‐fired chiller was produced in the USA by the Arkansas & Louisiana Gas Company

1991: Development of first gas fired heat pump commenced

2004: Launch of first gas powered heat 

pump

Page 4: Gas absorption heat pumps

Principle of Compression Heat Pump

Page 5: Gas absorption heat pumps

USEFUL EFFECT 

Expansion valve

Heat pump

Cold liquidVery cold liquid

Low temperature gas

Hot gas

Heating return 

Expansion valve

Principle of gas absorption heat pump

Page 6: Gas absorption heat pumps

Expansion valve

Heat pump

Cold liquidVery cold liquid

Low temperature gas

Hot gas

Heating return 

Expansion valve

1

2

3

4

5

6

7

1. GeneratorWithin the generator, the low Nox gas‐fired burner heats the ammonia/water solution via a heat exchanger, increasing the temperature and pressure. The strong ammonia vapour travels to the condenser (2) whilst the weak ammonia solution is circulated to the Absorber (5)  

How does a GAHP work? 

Page 7: Gas absorption heat pumps

Expansion valve

Heat pump

Cold liquidVery cold liquid

Low temperature gas

Hot gas

Heating return 

Expansion valve

1

2

3

4

5

6

7

2. Condenser The high temperature, high pressure ammonia vapour releases its heat into the heating system in the condenser. The vapour becomes a liquid and travels to the expansion valve (3) on its way to the evaporator (4)  

How does a GAHP work? 

Page 8: Gas absorption heat pumps

Expansion valve

Heat pump

Cold liquidVery cold liquid

Low temperature gas

Hot gas

Heating return 

Expansion valve

1

2

3

4

5

6

7

3. Expansion valve The high pressure ammonia passes through the expansion valve where the pressure falls. The ammonia now has a reduced boiling point and the liquid changes back to a vapour. This vapour passes on to the Evaporator (4) 

How does a GAHP work? 

Page 9: Gas absorption heat pumps

Expansion valve

Heat pump

Cold liquidVery cold liquid

Low temperature gas

Hot gas

Heating return 

Expansion valve

1

2

3

4

5

6

7

4. Evaporator A fan draws ambient air through the evaporator. The ambient air captured by the ammonia vapour, contains a high amount of free, renewable energy. The now heated, low pressure vapour passes on to the Absorber (5) 

How does a GAHP work? 

Page 10: Gas absorption heat pumps

Expansion valve

Heat pump

Cold liquidVery cold liquid

Low temperature gas

Hot gas

Heating return 

Expansion valve

1

2

3

4

5

6

7

5. Absorber In the absorber the weak ammonia solution recombines with the heated vapour, changing its state into a liquid. This releases further heat to the heating system. The now recombined ammonia solution is pumped (7) back to the generator.  

How does a GAHP work? 

Page 11: Gas absorption heat pumps

Expansion valve

Heat pump

Cold liquidVery cold liquid

Low temperature gas

Hot gas

Heating return 

Expansion valve

1

2

3

4

5

6

7

6. Second expansion valve This second valve controls the flow of weak ammonia between the Generator (1) and the Absorber (5) 

How does a GAHP work? 

Page 12: Gas absorption heat pumps

Expansion valve

Heat pump

Cold liquidVery cold liquid

Low temperature gas

Hot gas

Heating return 

Expansion valve

1

2

3

4

5

6

7

7. Heat pumpThe pump moves the ammonia solution from the Absorber (5) back to the Generator (1) where the process starts again. 

How does a GAHP work? 

Page 13: Gas absorption heat pumps

How does a GAHP work?

www.essaircon.com

Page 14: Gas absorption heat pumps

Ground Source Heat Pump

• Ground source (closed loop)

• Internal installation• Natural gas or LPG• Water temperature 65oC *• Efficiency (GUE) up to 170%• 60% less bore holes than electric heat pumps

• Simultaneous (GUE 244%)

Page 15: Gas absorption heat pumps

Ground Source Heat Pump

Refrigerant

•Water‐ammonia sealed circuit : no top‐up, no drain, extremely simple maintenance; • Natural refrigerant : no CFC, HCFC, HFC;• Global warming potential of zero•Ozone depletion potential of zero

Page 16: Gas absorption heat pumps

Ground Source Heat Pump

Electrical supply

• Single phase power supply required • Electrical consumption less than 0.5kW

Page 17: Gas absorption heat pumps

Ground Source Heat PumpGas Utilisation Efficiency

• EN14511 Brine 0oC Water 35oC

• GUE 170%

•To equate this to COP, electricity from the grid 40% efficient therefore relative COP of 4.11

Page 18: Gas absorption heat pumps

Ground Source Heat PumpCO2

• Grid electricity 0.4455 kg/CO2 kW/h 

• Natural gas 0.1840 kg/CO2 kW/h

Page 19: Gas absorption heat pumps

Ground Source Heat PumpBore Holes

• Total output of 42.6kW 

• Output from gas 25.6kW

• Output from the ground 17kW

Page 20: Gas absorption heat pumps

Ground Source Heat PumpBore Holes• Reduction in bore hole quantity of 60%• Reduction in civils costs• Reduction in area of bore field• Unit cost?•Bore hole cost?

Page 21: Gas absorption heat pumps

Ground Source Heat PumpBenefits summed upSingle phase low electrical consumptionGas or LPG ( Remote sites )Natural refrigerant, zero GWP and ODPLower civils costsLess bore field area requiredCO2 savings

A viable alternative to Electric ground source

Page 22: Gas absorption heat pumps

Air Source heat pump

• Air cooled • Heat pump• Natural gas or LPG • Water temperature upto65oC

• Seasonal efficiency 155%

Page 23: Gas absorption heat pumps

Gas condensing boiler

• Gas condensing boiler heat Pump

• Used to supplement or be used as “back up” 

• Hot water production• 80oC water temperature  • 98 % Efficient

Page 24: Gas absorption heat pumps

UK Future Energy Source? • Fracking‐Shale Gas• 1,300 Trillion ft3• Mainly found in Lancashire• Plans for West Sussex• UK currently use about 3 trillion ft3 a year

• 800 years of self sufficiency?

Page 25: Gas absorption heat pumps

Lowford Centre, Eastleigh

Community centre, Library and Doctors surgery

9* 100m closed loop boreholes3* GAHP‐GS heat pumps in 2 plant rooms130kW outputSingle phase supply50% running cost savings over traditional boilersSmall bore field under car park

Page 26: Gas absorption heat pumps

Open University, Milton Keynes

Building 12 admin offices

• 140kW  ground source ( 4 units)

• Exceeding peak efficiencies of 169%

• Saving 20.4 tons of CO2 (over condensing boilers

• BREEAM outstanding as a result of low emissions

• 5th place in BREEAM highest scoring office buildings in 2012

Page 27: Gas absorption heat pumps

Brief Robur history • Started in 1958 manufacturing gas burners still owned & operated by same family.

• HQ Bergamo Italy ‐220 staff• 30 Million Euro turnover ‐7% is reinvested in R&D. • 1991 bought the gas absorption technology from Electrolux 

• 2004 launched the first gas absorption heat pump.• 2005 started operating in UK• To date have over 300 systems installed in the UK.

Page 28: Gas absorption heat pumps

Who Are ESS• 2001 Appointed as the 1st National Distributor for Sanyo • Promoting their electric & gas driven heat pumps predominately to Consultants and end users.

• 2010 Samsung range of heat pumps added to our portfolio.

• 2012 Appointed as Robur’s UK Distributor due to our success offering heating & cooling solutions with our existing gas driven heat pump range.

Page 29: Gas absorption heat pumps

Thankyou