Page 1 Return to Top FUSION Remote Control Network - Installaon Diagrams Out-of-Box Installaons What Comes with the MS-NRX300 Remote Control .............................................................................................................. 2 Connecng a MS-RA70N to a MS-NRX300 Remote Control .................................................................................................. 3 Connecng a MS-BB100 to a MS-NRX300 Remote Control .................................................................................................. 4 650, 750 Series with MS-NRX300 Out-of-Box Installaon ..................................................................................................... 5 650, 750 Series with three MS-NRX300 Remotes .................................................................................................................. 6 Connecng a 650, 750 series to a standard NMEA2000 Network ......................................................................................... 7 MS-IP/AV700i with MS-NRX300 Remote................................................................................................................................ 8 MS-RA205 with MS-NRX300 Remote..................................................................................................................................... 9 FUSION Drop Cables ........................................................................................................................................................ 10 FUSION NMEA 2000 Connectors & Cables ........................................................................................................................ 11

FUSION Remote Control Network - Installation Diagrams · 2016-10-12 · Page 1 Return to Top FUSION Remote Control Network - Installation Diagrams Out-of-Box Installations What Comes

  • Upload
    vuquynh

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

Page 1

Return to Top

FUSION Remote Control Network - Installation Diagrams

Out-of-Box Installations

What Comes with the MS-NRX300 Remote Control ..............................................................................................................2

Connecting a MS-RA70N to a MS-NRX300 Remote Control ..................................................................................................3

Connecting a MS-BB100 to a MS-NRX300 Remote Control ..................................................................................................4

650, 750 Series with MS-NRX300 Out-of-Box Installation .....................................................................................................5

650, 750 Series with three MS-NRX300 Remotes ..................................................................................................................6

Connecting a 650, 750 series to a standard NMEA2000 Network .........................................................................................7

MS-IP/AV700i with MS-NRX300 Remote ................................................................................................................................8

MS-RA205 with MS-NRX300 Remote .....................................................................................................................................9

FUSION Drop Cables ........................................................................................................................................................ 10

FUSION NMEA 2000 Connectors & Cables ........................................................................................................................ 11

Page 2

Return to Top

Contents of the Box

1 x MS-NRX300 1 x dust cover 1 x user manual

1 x Warranty card 1 x hardware mounting kit 1 x 6M NMEA 2000 Backbone Cable

1 x NMEA 2000 T-Connector 1 x NMEA 2000 female Terminator 1 x NMEA 2000 in-line Terminator

The MS-NRX300 is a plug and play device with two connection options. Connect the remote control to your FUSION Marine Stereo with the standard cable kit provided or to a existing NMEA 2000 network.

What Comes with the MS-NRX300 Remote Control

Page 3

Return to Top

MS-NRX300MS-RA70N

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

Connecting a MS-RA70N to a MS-NRX300 Remote Control

1

23

In addition to the cables/connectors supplied with the NRX300 the following cables and connectors are also required

1 x CAB000581 NMEA 2000 - Tee - Connector 1 x CAB000541 NMEA 2000 - Power Cable 2M 1 x CAB000853-06 N2K - 6M Backbone Cable

1

2

3

12 VDC+-

* **

*

* Supplied with MS-NRX300

Page 4

Return to Top

MS-NRX300MS-BB100

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

Connecting a MS-BB100 to a MS-NRX300 Remote Control

1

2

In addition to the cables/connectors supplied with the BB100 and NRX300 the following cables and connectors are also required

1 x CAB000581 NMEA 2000 - Tee - Connector 1 x CAB000541 NMEA 2000 - Power Cable 2M

1

2

12 VDC+-

* **

*

* Supplied with MS-NRX300

Drop cable supplied with MS-BB100

Page 5

Return to Top

MS-NRX300

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

650, 750 Series with MS-NRX300 Out-of-Box Installation

WIREDREMOTE

NMEA 2000

Model

MS-UD650

MS-AV650

MS-UD750

MS-AV750

Applicable Models

Powering the Remote Control NetworkThe NRX Power option must be enabled when an optional remote is connected directly to the stereo as illustrated here.

1 Select MENU > Settings.2 Select NRX Power to select the check box. This enables the stereo to supply power to the optional remote.

NRX Power

Page 6

Return to Top

WIREDREMOTE

NMEA 2000

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

650, 750 Series with three NRX300 Remotes

MS-NRX300

MS-NRX300

MS-NRX300

Page 7

Return to Top

Connecting a 650, 750 series to a standard NMEA2000 Network

WIREDREMOTE

NMEA 2000

Connecting to an existing NMEA 2000 NetworkThe stereo is configured by default to work with a NMEA 2000 network (NRX Power = OFF). Enabling the NRX Power option when the stereo is connected to a NMEA 2000 network may damage other devices on the NMEA 2000 network. Ensure the stereo is not providing power to the NMEA 2000 network as follows;

1 Select MENU > Settings.2 Ensure the NRX Power check box is not selected.

Model

MS-UD650

MS-AV650

MS-UD750

MS-AV750

Applicable Models

NRX Power

Page 8

Return to Top

MS-NRX300

Powered Drop Cable (Red)Part # CAB000851

* Supplied with Stereo

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

MS-IP/AV700i with MS-NRX300 Remote

MS-IP/AV700i

Page 9

Return to Top

MS-NRX300

Powered Drop Cable (Red)Part # CAB000862

* Supplied with Stereo

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

NMEA2000 TERMINATOR LOCATED AT END OF

NETWORK

MS-RA205 with MS-NRX300 Remote

MS-RA205

Page 10

Return to Top

Powered (Red)

CAB000851

Powered (Red)

CAB000862

Non-Powered (Black)

CAB000863

Non-Powered (Black)

CAB000852

MS-AV700iMS-IP700i

MS-AV700iMS-IP700i

MS-RA205 MS-RA205

FUSION Drop Cables

Page 11

Return to Top

FUSION NMEA 2000 Connectors & Cables

CAB000581 NMEA 2000 Tee - Connector

CAB000850 NMEA 2000 - Terminator – Inline

CAB000857 NMEA 2000 - Terminator – Female

CAB000858 NMEA 2000 - Terminator – Male

CAB000853-06 NMEA 2000 - 6M Backbone CableCAB000853-20 NMEA 2000 - 20M Backbone Cable

CAB000541 NMEA 2000 - Power Cable 2M