14
Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7 EXAMPLE 1-009 FRAME PRESTRESS APPLIED TO FRAME OBJECTS EXAMPLE DESCRIPTION The SAP2000 prestress applied to frame objects is verified in this example using a simply supported concrete beam with a parabolic prestressing tendon profile and different eccentricities at each end. The bending moment and deflection at the beam center are compared with independent hand-calculated results. SAP2000 has two options for modeling the effect of the prestress. One option models the prestress as loads applied to the structure. The other models the prestress tendon as internal tendon elements. Both options are verified in this example. In SAP2000 the beam is modeled using a single frame element that is internally meshed into two elements so that there is a node at the beam midpoint where the displacement values are to be calculated. Three separate models are used in this analysis. Model A has the prestress modeled as loads. Models B and C treat the prestress as elements. Model B has a maximum prestress tendon discretization length of 60 inches and Model C reduces the maximum prestress tendon discretization length to 12 inches. The effect of both wobble and curvature friction losses are included in the example as well as elastic shortening of the concrete beam. The tendon is stressed from the left end only. Important Note: Shear deformations are included in this example. EXAMPLE 1-009 - 1

FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

  • Upload
    votram

  • View
    233

  • Download
    4

Embed Size (px)

Citation preview

Page 1: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 FRAME – PRESTRESS APPLIED TO FRAME OBJECTS

EXAMPLE DESCRIPTION The SAP2000 prestress applied to frame objects is verified in this example using a simply supported concrete beam with a parabolic prestressing tendon profile and different eccentricities at each end. The bending moment and deflection at the beam center are compared with independent hand-calculated results.

SAP2000 has two options for modeling the effect of the prestress. One option models the prestress as loads applied to the structure. The other models the prestress tendon as internal tendon elements. Both options are verified in this example.

In SAP2000 the beam is modeled using a single frame element that is internally meshed into two elements so that there is a node at the beam midpoint where the displacement values are to be calculated.

Three separate models are used in this analysis. Model A has the prestress modeled as loads. Models B and C treat the prestress as elements. Model B has a maximum prestress tendon discretization length of 60 inches and Model C reduces the maximum prestress tendon discretization length to 12 inches.

The effect of both wobble and curvature friction losses are included in the example as well as elastic shortening of the concrete beam. The tendon is stressed from the left end only.

Important Note: Shear deformations are included in this example.

EXAMPLE 1-009 - 1

Page 2: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

GEOMETRY AND LOADING

Section A-A

CLCL

10" 3"

10"

30' = 360"

30"

18"Prestressing tendonT=220 k

Material PropertiesE = 3600 k/in2

ν = 0.2G= 1500 k/in2

Section Propertiesb = 18 ind = 30 inA = 540 in2

I = 40,500 in4

Av = 450 in2 (shear area)Prestressing Tendon Notes1.2.3.4.5.6.7.

T is the component of the tension force in the prestressing tendon before losses.The tendon is tensioned from the left end only.The cable drapes at the left end, center and right end of the beam are illustrated in the figure.The cable profile is parabolic.The friction loss coefficient for curvature is 0.15.The friction loss coefficient for wobble is 0.0001 / in.Consider losses due to friction and beam elastic shortening.

Beam neutral axis

Prestress Properties

A

A

A = 1.5 in2E = 29000 k/in2ν = 0.3

TECHNICAL FEATURES OF SAP2000 TESTED Prestress tendon with parabolic tendon profile and different eccentricities at

the two ends Prestress tendon modeled using loads Prestress tendon modeled as elements Prestress losses

EXAMPLE 1-009 - 2

Page 3: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

RESULTS COMPARISON Independent results are hand calculated using basic principles and using the unit load method described on page 244 in Cook and Young 1985.

Important Note: A simplifying assumption is made in the hand calculations that the distributed load the prestress imposes on the beam is uniform. Thus the SAP2000 and hand-calculated results are not expected to match exactly.

Model Output

Parameter SAP2000 Independent Percent

Difference

A- By Loads Uz

(center) in

0.17028

0.16564

+2.8%

B- Elems (60") 0.16041 -3.2%

C- Elems (12") 0.16484 -0.5%

A- By Loads My

(center) kip-in

-2061.5

-2004.3

+2.9%

B- Elems (60") -2013.9 +0.5%

C- Elems (12") -2001.7 -0.1%

COMPUTER FILES: Example 1-009a, Example 1-009b, Example 1-009c

CONCLUSION The SAP2000 results and the independent results show an acceptable match.

EXAMPLE 1-009 - 3

Page 4: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

HAND CALCULATION

EXAMPLE 1-009 - 4

Page 5: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 5

Page 6: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 6

Page 7: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 7

Page 8: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 8

Page 9: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 9

Page 10: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 10

Page 11: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 11

Page 12: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 12

Page 13: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 13

Page 14: FRAME PRESTRESS APPLIED TO FRAME OBJECTS - …docs.csiamerica.com/manuals/sap2000/Verification/Anal… ·  · 2017-05-17The SAP2000 prestress applied to frame objects verified in

Software Verification PROGRAM NAME: SAP2000 REVISION NO.: 7

EXAMPLE 1-009 - 14