2
PM02 MCH01 AMC01 AMC02 AMC03 AMC04 AMC05 AMC06 AMC07 AMC08 AMC09 AMC10 AMC11 AMC12 MCH02 PM03 PM04 PM01 Comm on Options MCH1 Fabric [A] to AMC P ort 0 Comm on Options MCH2 Fabric [A] to AMC P ort 1 4 4 AMC P ort 2 AMC P ort 3 Fat Pipe MCH1 Fabric [D:G ] to AMC Port [4:7] 4 4 4 4 4 4 4 4 4 4 4 Extend. Fat Pipe MCH2 Fabric [D:G ] to AMC P ort [8:11] 4 4 4 4 4 4 4 4 4 4 4 Clocks MCH1 CLK1 to AMC T CLKA Clocks MCH2 CLK1 to AMC T CLKC Clocks AMC T CLKB to MCH1 CLK2 Clocks AMC T CLKD to MCH2 CLK2 Clocks MCH1 CLK3 to AMC F CLKA AMC Port 12 AMC Port 13 AMC Port 14 AMC Port 15 AMC Port 17 AMC Port 18 AMC Port 19 AMC Port 20 MICROTCA WITH RTM FOR PHYSICS APPLICATIONS ∙ Front slots conform to MicroTCA specification PICMG MTCA.0 R1.0 2 x MCH slots Single/Double full-size 12 x AMC slots Single/Double mid-size 4 x PM slots Single/Double full-size ∙ Rear slots according to PICMG MTCA.4 draft 12 x RTM slots Double mid-size ∙ Two redundant hot-swap fan trays with EMMC for AMC and uRTM cooling in push-pull configuration. ∙ Air Flow: bottom front air intake, top rear air exhaust ∙ Chassis dimensions: Width: 19” rack mount Height: 9 U Depth: 373.30 mm The chassis is designed for high availability physics applications where redundancy of all chassis modules is required. The two push-pull fan trays are removable from the front of the chassis. Cable trays at the front and rear of the chassis facilitate management of cables. The chassis accepts up to four MTCA.0 compliant power modules. Part number The order number is 11890-035. Delivery comprises: subrack, backplane, two removable fan trays, air filter. Backplane topology The backplane includes special bused connections for triggers, clocks, and interlocks. It also includes point-to-point SAS/SATA and fabric connections between AMCs. ELECTRONICS PROTECTION MICROTCA

FOR PHYSICS APPLICATIONS · 2014. 5. 15. · MCH2 CLK2 Clocks MCH1 CLK3 to AMCF CLKA AMCP ort1 2 AMCP ort1 3 AMCP ort1 4 AMCP ort1 5 AMCP ort1 7 AMCP ort1 8 AMCP ort1 9 AMCP ort2

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FOR PHYSICS APPLICATIONS · 2014. 5. 15. · MCH2 CLK2 Clocks MCH1 CLK3 to AMCF CLKA AMCP ort1 2 AMCP ort1 3 AMCP ort1 4 AMCP ort1 5 AMCP ort1 7 AMCP ort1 8 AMCP ort1 9 AMCP ort2

PM02

MCH

01

AMC0

1

AMC0

2

AMC0

3

AMC0

4

AMC0

5

AMC0

6

AMC0

7

AMC0

8

AMC0

9

AMC1

0

AMC1

1

AMC1

2

MCH

02

PM

03

PM

04

PM01

Comm on OptionsMCH1 Fabric [A] to

AMC P ort 0Comm on OptionsMCH2 Fabric [A] to

AMC P ort 1

44

AMC P ort 2

AMC P ort 3

Fat PipeMCH1 Fabric [D:G]to AMC P ort [4:7]

44444444444

Extend. Fat PipeMCH2 Fabric [D:G]to AMC P ort [8:11]

44444444444

ClocksMCH1 CLK1 toAMC T CLKA

ClocksMCH2 CLK1 toAMC T CLKC

ClocksAMC T CLKB to

MCH1 CLK2Clocks

AMC T CLKD toMCH2 CLK2

ClocksMCH1 CLK3 toAMC FCLKA

AMC P ort 12

AMC P ort 13

AMC P ort 14

AMC P ort 15

AMC P ort 17

AMC P ort 18

AMC P ort 19

AMC P ort 20

MICROTCA WITH RTM FOR PHYSICS APPLICATIONS

∙ Front slots conform to MicroTCA specification PICMG MTCA.0 R1.0 2 x MCH slots Single/Double full-size 12 x AMC slots Single/Double mid-size 4 x PM slots Single/Double full-size

∙ Rear slots according to PICMG MTCA.4 draft 12 x RTM slots Double mid-size

∙ Two redundant hot-swap fan trays with EMMC for AMC and uRTM cooling in push-pull configuration.

∙ Air Flow: bottom front air intake, top rear air exhaust

∙ Chassis dimensions: Width: 19” rack mount Height: 9 U Depth: 373.30 mm

The chassis is designed for high availability physics applications where redundancy of all chassis modules is required. The two push-pull fan trays are removable from the front of the chassis. Cable trays at the front and rear of the chassis facilitate management of cables. The chassis accepts up to four MTCA.0 compliant power modules.

Part number The order number is 11890-035. Delivery comprises: subrack, backplane, two removable fan trays, air filter.

Backplane topology The backplane includes special bused connections for triggers, clocks, and interlocks. It also includes point-to-point SAS/SATA and fabric connections between AMCs.

ELECTRONICS PROTECTION MICROTCA

Page 2: FOR PHYSICS APPLICATIONS · 2014. 5. 15. · MCH2 CLK2 Clocks MCH1 CLK3 to AMCF CLKA AMCP ort1 2 AMCP ort1 3 AMCP ort1 4 AMCP ort1 5 AMCP ort1 7 AMCP ort1 8 AMCP ort1 9 AMCP ort2

FOR FURTHER INFORMATION VISIT: www.schroff.co.uk/physics

CHASSIS COMPONENTS

1 – Push-Pull fan trays2 – MCH slots3 – Power Module slots4 – 12 double / mid-size AMC slots5 – Air intake

1 – MicroTCA Backplane for 12 double / mid-size uRTM2 – Cable tray3 – Slot covers4 – Air exhaust

88 8

8

Front view:

Width: 19"- rack mount

Rear view: Air flow:

Hei

ght:

9U

The air intake is at the front bottom side of the chassis, the air exhaust is the rear upper side. Air baffles separate the air flow for the front card section and the rear card section in order to maximize cooling capability.

POWER DISTRIBUTION The chassis accepts up to four MTCA.0 compliant Power Modules which are plugged in from the front side of the chassis. There are two adjacent Power Module slots at the left side and two adjacent Power Module slots at the right side of the chassis allowing various Power Module combinations; though not all Power Module sizes are available on the market today:

- 4 single wide / full-size (6 HP)

- 4 double wide / full-size (6 HP)

- 2 single wide / 12 HP wide (double width of full-size)

- 2 double wide / 12 HP wide (double width of full-size)

EUROPEStraubenhardt, Germany Tel: +49.7082.794.0Betschdorf, France Tel: +33.3.88.90.64.90Warsaw, Poland Tel: +48.22.60.70.616

Hemel Hempstead, Great Britain Tel: +44.1442.24.04.71Skarpnäck, Sweden Tel: +46.8.683.61.00

Pregnana Milanese, Italy Tel: +39.02.932.714.1Moscow, Russia Tel: +7.495.730.52.53

MIDDLE EAST & AFRICADubai, United Arab Emirates Tel: +971.4.37.81.700

Langenalber Str. 96-100, D-75334 Straubenhardt© Pentair Electronics Protection, 2014

WWW.SCHROFF.BIZ39601-555