23
D D D D D D Note 1) DN1’s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs. Note 2) Please consult SMC for networks other than those above. Communication protocol DN1 DN1-X26 MJ1 CS1 CS2 SL1 SL2 UW1 UH1 CM1 CM3 DeviceNet Note 1) DeviceNet Note 1) CC-Link OMRON Corp.: CompoBus/S (16 outputs) OMRON Corp.: CompoBus/S (8 outputs) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs) NKE Corp.: Fieldbus System NKE Corp.: Fieldbus H System CompoNet™ NPN (Positive common) CompoNet™ PNP (Negative common) CE-compliant SV1000/2000/3000/4000 VQ1000/2000 SY3000/5000 SY3000/5000 SY3000/5000 Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks Series EX120 Series EX121 Series EX122 How to Order SI Unit 0 1 2 Plug-in Flat ribbon cable DIN rail mounting Plug-in DIN rail mounting DN1 EX12 S 0 Valve interface Series EX120/121/122 For Output 2051 EX140 EX180 EX260 EX250 EX600 EX500 EX510 PCA EX EX12

For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

DD

DD

DD

Note 1) DN1’s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs.

Note 2) Please consult SMC for networks other than those above.

Communication protocolDN1DN1-X26MJ1CS1CS2SL1SL2UW1UH1CM1CM3

DeviceNet Note 1)

DeviceNet Note 1)

CC-Link

OMRON Corp.: CompoBus/S (16 outputs)

OMRON Corp.: CompoBus/S (8 outputs)

Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)

Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)

NKE Corp.: Fieldbus System

NKE Corp.: Fieldbus H System

CompoNet™ NPN (Positive common)

CompoNet™ PNP (Negative common)

CE-compliant

SV1000/2000/3000/4000

VQ1000/2000

SY3000/5000

SY3000/5000 SY3000/5000

Small unit compatible with maximum 16 outputsCompatible with a variety of communication networks

Series EX120 Series EX121 Series EX122

How to Order SI Unit

012

Plug-in

Flat ribbon cable DIN rail mounting

Plug-in DIN rail mounting

DN1EX12 S0Valve interface

Series EX120/121/122For Output

2051

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX12

Page 2: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

Note 1) Please note that the version is subject to change.Note 2) Each file can be downloaded from SMC’s website (http://www.smcworld.com).Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website. (http://www.smcworld.com).Note 4) Since this is a special product, a manifold part number is not specified. Please consult SMC for the manifold integrated type.

Model EX12-SDN1

DeviceNet™

Release 2.0

125 k/250 k/500 kbps

100 mA or lessSink/NPN (Positive common)

IP20

35 to 85%RH (With no condensation)1500 VAC for 1 min. between whole external terminal and enclosure

2 MΩ or more (500 VDC) between whole external terminal and enclosure

EX120: 110 g or less, EX121: 140 g or less, EX122: 130 g or less

24 VDC+10%/–5%

EDS file

16/16

CE marking

Communication connector 1 pc.,Power supply connector 1 pc.

0/16

Note 4)

EX12-SDN1-X26 EX12-SMJ1

CC-Link

EX12-SCS1EX12-SCS2

EX12-SSL1EX12-SSL2 EX12-SUW1 EX12-SUH1

Ver. 1.10 — — — —

156 k/625 kbps2.5 M/5 M/10 Mbps 750 kbps 28.5 kbps 28.5 kbps 29.4 kbps

32/32 (1 station, remote I/O stations)

Not provided

Communication speed

Configuration file Note 2)

Terminating resistorFor unit For valve

Output type

Number of outputs

Load

Enclosure

Operating humidity rangeWithstand voltageInsulation resistance

Applicable system

Protocol

Version Note 1)

Internal current consumption (Unit)

StandardsWeight

Accessory

0 to +55°C (Valve 8 points ON)0 to +50°C (Valve 16 points ON)

CompoNet™ Communication Specifications

SI Unit Specifications

ProtocolCommunication speedConfiguration fileI/O occupation area (Inputs/Outputs)Terminating resistor

CompoNet™93.75 kbps/1.5 M/3 M/4 Mbps

EDS file (Download from SMC’s website)0/16

Not provided

Note) For details about the communication speed or each setting instruction, check the operation manual that can be downloaded from SMC website.

Note) Communication connector (for the opposite side) is not provided.

Model

Power supply voltage

Internal current consumption (Unit)

Output

Environment

StandardsWeightAccessory

For unitFor valve

Output type(Valve common polarity)Number of outputsLoadFail safeEnclosure

Operating temperature range

Operating humidity rangeWithstand voltageInsulation resistance

14 to 26.4 VDC24 VDC+10%/–5%

100 mA or less

35 to 85%RH (With no condensation)1500 VAC for 1 min. between whole external terminal and enclosure

2 MΩ or more (500 VDC) between whole external terminal and enclosureCE marking

EX120: 100 g or less, EX121: 120 g or less, EX122: 110 g or less (including accessory)Power supply connector (EX9-CP2) 1 pc.Note)

16 pointsSolenoid valve with/surge voltage suppressor 24 VDC, 2.1 W or less (SMC)

Hold/Clear (Setting via network)IP20

0 to +55°C (Valve 8 points ON)0 to +50°C (Valve 16 points ON)

Sink/NPN output (Positive common) Source/PNP (Negative common)

EX120-SCM1 EX121-SCM1 EX122-SCM1 EX120-SCM3 EX121-SCM3 EX122-SCM3

SI Unit Specifications

OMRON Corp.:CompoBus/S

NKE Corp.:Fieldbus System

NKE Corp.:Fieldbus H System

SCS1: 0/16SCS2: 0/8

SSL1: 0/16SSL2: 0/8 0/16 0/16

11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/–5%(Common power supply)

24 VDC±10%(Common power supply)

16 pointsSCS1/SSL1: 16 pointsSCS2/SSL2: 8 points 16 points

Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC)Hold/Clear

(Switch setting) ClearClearHold/Clear

(Switch setting) Clear

Co

mm

un

icat

ion

Power supply voltage

Ou

tpu

tE

nvi

ron

men

t

I/O occupation area (Inputs/Outputs)

Fail safe

Operating temperature range

Series EX120/121/122

Panasonic Industrial Devices SUNX Co., Ltd.:

S-Link

2052

Page 3: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

9.5

60.8

28.864

29.5

60.8

28.864

60.8

64 1.2 28.8

10.2

5.4

60.8

28.864

5.4

10.2 228.8

60.8

64

10.2

5.4

60.8

28.864

MIL connector (20 pins, socket)

OUT

5.4

60.8

64 10.2 28.8

OUT

5.4

60.8

64 10.2 28.8 2

OUT

28.864

60.8

Communication connector

Valve power supply

Terminal block cover

Position indicator LED

10.2

5.4

Terminal block cover

Position indicator LED

Communication connector

Valve power supply

Terminal block cover

Position indicator LED

Communication connector

Valve power supply

Position indicator LED

Terminal block cover

Screw terminal block

Position indicator LED

Terminal block cover

Power supply connector

Communication connector

Position indicator LED

Terminal block cover

Screw terminal block

DIN rail mounting bracket

MIL connector(20 pins, socket)

Position indicator LED

Terminal block cover

Screw terminal block

DIN rail mounting bracket

MIL connector(20 pins, socket)

Position indicator LED

Terminal block cover

Power supply connector

Communication connector

MIL connector(20 pins, socket)

DIN rail mounting bracket

Terminal block cover

Position indicator LED

Screw terminal block

DIN rail mounting bracket

Terminal block cover

Position indicator LED

Power supply connector

Communication connector

DIN rail mounting bracket

EX120EX120-SMJ1, SCS,SSL, SUW1, SUH1

EX120-SDN1(-X26) EX120-SCM

EX121EX121-SMJ1, SCS,SSL, SUW1, SUH1

EX121-SDN1(-X26) EX121-SCM

EX122EX122-SMJ1, SCS,SSL, SUW1, SUH1

EX122-SDN1(-X26) EX122-SCM

SI Unit Dimensions/Parts Description

For Output Series EX120/121/122

2053

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX12

Page 4: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

How to Order Options (For EX12-SCM)

Cable identification label(Flat cable: Black, blue, white, red)

Black

Lock lever

Black

Lock lever

Cable identification label(Flat cable: Black, blue, white, red)

Power supply connector: T-branch type power supply connector.

EX9-CP3

Power supply connector: Straight type power supply connector. This connector is supplied at shipment.

EX9-CP2

Communication connector: Terminal block connector for round cable (VCTF).Use this connector for the VCTF cable.

EX9-CCM2

Communication connector: Press-in connector for flat cable.Use this connector for the standard dedicated flat cable.

EX9-CCM1

Series EX120/121/122

2054

Page 5: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

DD

D

D

D

3Common power supply of unit and valveEnclosure IP65Compatible with the VQ valves

Mounting specifications

SL1SL2UW1UH1

Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)

Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)

NKE Corp.: Fieldbus System

NKE Corp.: Fieldbus H System

CE-compliant

CE-compliant

DN1DN1-X26MJ1CS1CS2

DeviceNet Note)

DeviceNet Note)

CC-Link

OMRON Corp.: CompoBus/S (16 outputs)

OMRON Corp.: CompoBus/S (8 outputs)

MJ1 CC-Link

CE-compliant

Series EX123VQ2000/4000/5000

Series EX124VQ2000/4000/5000

Series EX126

SV1000/2000/3000

SY3000/5000

VQC1000/2000/4000

Note) DN1’s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs.

Enclosure IP65 (EX123, EX124), IP67 (EX126)Maximum 16 outputs

How to Order SI Unit

Unit specifications

SL1EX12 SU3Communication protocol

UD

Mount a unit to the U side of the manifold

Mount a unit to the D side of the manifold

Unit specifications

4Separate power supply of unit and valve Enclosure IP65Compatible with the VQ valves

UD

Mount a unit to the U side of the manifold

Mount a unit to the D side of the manifold

DN1EX12 SU4

Mounting specifications

Communication protocol

Unit specifications

6Separate power supply of unit and valve Enclosure IP67 Compatible with the SY/SV/VQC valves

D Mount a unit to the D side of the manifold

MJ1EX12 SD6

Mounting specifications

Communication protocol

Series EX123/124/126For Output

2055

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX12

Page 6: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

SI Unit Specifications

The electrical specification is the same for EX12. Refer to page 2052.The weight of the EX123, 124, or 126 is 240g or less.4 unit mounting screws (M4 x 10) are included when shipped.

How to Order Options

Fuse for replacementA fuse for replacement used for EX126D-SMJ1.

EX9 FU20Applicable model

Rated current

EX126D-SMJ1

2.0 A

Dripproof plug assemblyUse for the unused conduit port (G1/2).

AXT100 B04A

Fuse

Series EX123/124/126

2056

Page 7: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

16.8

Housing cover

19.8

65.7

68.2

6.6

30.4

42

(72.

5)

5.5

67

114

35.3

19.8

4 x G1/2Conduit port

(72.

5)

5.5

56.4

19

11.6

53.8

19

19.8

67

114

Housing cover

Position indicator LEDScrew terminal block

Housing cover diagram

EX123: 2 x G1/2EX124: 4 x G1/2Conduit port

Housing cover diagram

Position indicator LED Screw terminal block

Housing bottom diagram

Power supply fuse for solenoid valve

Power supply fuse for communication

Note) The housing cover of the EX124U/D-SMJ1 is the same as that of the EX126D-SMJ1.

EX126D-SMJ1

SI Unit Dimensions/Parts Description

EX123-S, EX124-S

For Output Series EX123/124/126

2057

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX12

Page 8: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

DN1EX140 SCommunication protocol

DN1MJ1CS1CS2SL1SL2UW1UH1

DeviceNet™

CC-Link

OMRON Corp.: CompoBus/S (16 outputs)

OMRON Corp.: CompoBus/S (8 outputs)

Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)

Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)

NKE Corp.: Fieldbus System

NKE Corp.: Fieldbus H System

CE-compliant

Note) Please consult SMC for networks other than those above.

SZ3000 SQ1000/2000

Thinner unit with low heightMaximum 16 outputs

How to Order SI Unit

Series EX140For Output

2058

Page 9: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

33.4

(36)(11.

5) 34.494.5

34.494.5

33.4

Position indicator LEDPosition indicator LED

Power supply connector

Communication connectorScrew terminal block

Standards

Weight

Accessory

EX140-SDN1 EX140-SMJ1 EX140-SCS1EX140-SCS2

EX140-SSL1EX140-SSL2

EX140-SUW1 EX140-SUH1

SI Unit Specifications

Model

Communication speed

Configuration file Note 2)

Terminating resistor

For unit

For valve

Output type

Number of outputs

Load

Enclosure

Operating humidity range

Withstand voltage

Insulation resistance

Applicable system

Protocol

Version Note 1)

Internal current consumption (Unit)

Fail safe

Operating temperaturerange

I/O occupation area (Inputs/Outputs)

Co

mm

un

icat

ion

Ou

tpu

tE

nvi

ron

men

t

Power supply voltage

DeviceNet™

Release 2.0

125 k/250 k/500 kbps

11 to 25 VDC

16 outputs

Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC)

24 VDC+10%/–5%

EDS file

0/16

Hold/Clear(Switch setting)

CE marking

Communication connector 1 pc.,Power supply connector 1 pc.

32/32(1 station, remote

I/O stations)

CC-LinkOMRON Corp.:CompoBus/S

Panasonic Industrial Devices SUNX Co., Ltd.:

S-Link

NKE Corp.:Fieldbus System

NKE Corp.:Fieldbus H System

Ver. 1.10 — — — —

156 k/625 kbps2.5 M/5 M/10 Mbps

750 kbps 28.5 kbps

28.5 kbps 29.4 kbps

SCS1: 0/16SCS2: 0/8

SSL1: 0/16SSL2: 0/8

Not provided

0/16

15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/–5%(Common

power supply)

100 mA or less

Sink/NPN (Positive common)

IP20

35 to 85%RH (With no condensation)

1500 VAC for 1 min. between whole external terminal and enclosure

2 MΩ or more (500 VDC) between whole external terminal and enclosure

80 g or less

SCS1/SSL1: 16 outputsSCS2/SSL2: 8 outputs

0 to +55°C (Valve 8 points ON)0 to +50°C (Valve 16 points ON)

16 outputs

Clear

24 VDC±10%(Common power supply)

Note 1) Please note that the version is subject to change.Note 2) Each file can be downloaded from SMC website (http://www.smcworld.com).Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).

SI Unit Dimensions/Parts Description

EX140-SMJ1, SCS, SSL, SUW1, SUH1 EX140-SDN1

For Output Series EX140

2059

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX140

Page 10: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

®

RoHS

Communication protocolDN3DN4DN5DN6MJ3MJ5

DeviceNet™ (32 points Sink/NPN (Positive common))

DeviceNet™ (16 points Sink/NPN (Positive common))

DeviceNet™ (32 points Source/PNP (Negative common))

DeviceNet™ (16 points Source/PNP (Negative common))

CC-Link (32 points Sink/NPN (Positive common))

CC-Link (32 points Source/PNP (Negative common))

Note) Please consult SMC for networks other than those above.

SJ2000/3000 S0700

EX180-C1 EX180-C2

Note) S0700 is not yet UL-compatible.

Thinner unit with low heightMaximum 32 outputs

How to Order SI Unit

DN3EX180 SCommunication connector typeNil

AT-branch type

Straight type

Note) Communication and power supply connectors are included.

How to Order Options

Communication connectorConnector for the network cable, included when shipped.

EX180 C DN 1

DNMJ

Communicationprotocol

For EX180-SDNFor EX180-SMJ

12

Communication connector typeT-branch typeStraight type

Power supply connectorConnector for power supply, included when shipped.

EX180 CP1

Series EX180For Output

2060

Page 11: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

EX180-SDN5EX180-SDN6

EX180-SMJ5EX180-SDN3EX180-SDN4

EX180-SMJ3

SI Unit Specifications

Model

Co

mm

un

icat

ion

Ou

tpu

tE

nvi

ron

men

t

Communication speed

Configuration file Note 2)

Terminating resistor

For unit

For valve

Output type

Number of outputs

Load

Enclosure

Operating temperature range

Operating humidity range

Withstand voltage

Insulation resistance

Applicable system

Protocol

Version Note 1)

Power supply voltage

Internal current consumption (Unit)

I/O occupation area (Inputs/Outputs)

Fail safe

Standards

Weight

Accessory

DeviceNet™

Release 2.0

125 k/250 k/500 kbps

Not provided

11 to 25 VDC

0.1 A or less

EDS file

Communication connector 1 pc.,Power supply connector 1 pc.

Communication connector 1 pc.,Power supply connector 2 pcs.

Ver. 1.10

CC-Link

32/32 (1 station)

32 outputs

15 to 30 VDC

SDN3: 32 outputsSDN4: 16 outputs

SDN5: 32 outputsSDN6: 16 outputs

Series SJ2000/3000, S0700 manifold valves

Series SJ2000/3000, S0700 manifold valves

IP20

–10 to 50°C

35 to 85%RH (With no condensation)

500 VAC for 1 min. between whole external terminal and FG

10 MΩ or more (500 VDC) between whole external terminal and FG

CE marking, UL (CSA)

110 g or less (including accessory)

Source/PNP (Negative common)Sink/NPN (Positive common) Source/PNP (Negative common)Sink/NPN (Positive common)

24 VDC±10%/–5%

156 k/625 kbps2.5 M/5 M/10 Mbps

Built into the unit (Switch setting, 110 Ω)

Hold/Clear(Switch setting)

Note 1) Please note that the version is subject to changeNote 2) Each file can be downloaded from SMC website (http://www.smcworld.com).Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website

(http://www.smcworld.com).Note 4) The EX180-SDN1/2 cannot be mounted on the manifold for the EX180-SDN3/4/5/6. Additionally, the EX180-SDN3/4/5/6 cannot be

mounted on the manifold for the EX180-SDN1/2.Note 5) The EX180-SMJ1 cannot be mounted on the manifold for the EX180-SMJ3/5. Additionally, the EX180-SMJ3/5 cannot be mounted on the manifold

for the EX180-SMJ1.

SDN3: 0/32SDN4: 0/16

SDN5: 0/32SDN6: 0/16

For Output Series EX180

2061

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX180

Page 12: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

93.3

80

77

42.3

93.3

80

77

42.3

EX180-SMJ3, SMJ5

EX180-SDN3, SDN4, SDN5, SDN6

SI Unit Dimensions/Parts Description

(39.

7)

30.9

Power supply connector(For solenoid valve)

Power supply connector(Control unit power supply for SI unit)

Communication connector

M3Ground terminal

Before mounting connector (accessory)

Power supply connector(For solenoid valve)

Communication connector

Before mounting connector (accessory)

M3Ground terminal

(39.

7)

30.9

Series EX180

2062

Page 13: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

®

RoHS

IP67IP67 IP67 IP40

Top ported valve Bottom ported valve Side ported valveMixed valve sizes manifold

7 mm width valve

Applicable Fieldbus protocols

Series EX260Fieldbus System

(Output device for driving 5 port solenoid valves)

Daisy-chain wiringcommunication

Space-saving InstallationSpace-saving InstallationCompact

28mm

IP67∗∗ For units with D-sub connector, and when connected to S0700 manifolds, it is IP40.

Drives up to 32 solenoids

2063

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX260

Page 14: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

PWR

BUS IN

BUS OUT

E3/5

1 P

E3/5

1 P

B

4 A

2 B

4 A

2 B

4 A

2 B

4 A

2 B

4 A

2

PWR

BUS IN

BUS OUT

E3/5

1 P

E3/5

1 P

B

4 A

2 B

4 A

2 B

4 A

2 B

4 A

2 B

4 A

2

Product Specification Variations

M12 communicationconnector(PROFIBUS DP)

D-sub communicationconnector(PROFIBUS DP)

16

32

PNP

NPN

M12

D-sub

16

32

PNP

NPN

M12

16

32

PNP

NPN

M12

16

32

PNP

NPN

M12

16

32

PNP

NPN

M12

28.2 mm81 mm

Communication connector examples

Fieldbus

EX260

16

32

PNP

NPN

M12

Manifold length is shortened by the small fieldbus output module (SI unit).

Wiring and piping from the same direction is possible.(for side ported)Effective for installation in locations where space is limited above the valve.

Existing model EX250

External branch connector is not necessary. Daisy-chain wiring is possible. Reduced wiring space

Branch connectorExisting model (EX250)

External terminating resistor is not necessary.(Only available for M12 PROFIBUS DP, CC-Link communication connectors)

ON/OFF switching is possible with an internal terminating resistor. External terminating resistor is not necessary.

External terminating resistor

Internal terminatingresistor

SI unit

Number ofoutputs

Outputpolarity

Communicationconnector

2064

Page 15: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

SY3000

SY5000

S0700

SV1000

SV2000

SV3000

VQC1000

VQC2000

VQC4000

0.35 (standard)0.1 (with power-

saving circuit)32

32

32

24

0.6

0.4 (standard)

1.0 (standard)

0.35

IP67

IP40

IP67

IP67

0.19

0.17

0.39

0.35

0.18

0.21

0.30

0.30

0.38

1.6

3.6

0.37

1.1

2.4

4.3

1.0

3.2

7.3

SeriesPower

consumption(W)

Enclosure StandardsFlow-rate characteristics (4/2→5/3)

C [dm3/(s·bar)] b

Maximumnumber ofsolenoids

Applicable Valve Series

Note) For units with D-sub communication connector, it is IP40.

®

Side ported Side ported

Bottom ported

Top ported<Example of Use>

Valve piping direction variations

Series SY3000/5000 Pressure switch

Piping is possible from 3 directions.

Mixed mounting of top ported and side ported is possible.

By mounting top ported valves on side ported and bottom ported type manifolds, it is possible to detect the output of the A/B port with a pressure switch.

Valves can be freely connected up to 24 stations. Mixed valve sizes manifoldValves of different sizes,

SY3000 and SY5000, can be mounted on the same manifold.

It is possible to connect only the number of valves required, from 1 to 24 stations, to suit the application.(Maximum number of solenoids connected: 32)

7 mm width valves can be connected.

It is possible to connect only the number of 7 mm width valves required, from 1 to 24 stations. (Maximum number of solenoids connected: 32)

Series S0700

2065

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX260

Page 16: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

M12

DN1DN2DN3DN4PR1PR2PR3PR4PR5PR6PR7PR8MJ1MJ2MJ3MJ4EC1EC2EC3EC4PN1PN2PN3PN4EN1EN2EN3EN4

DeviceNet™

PROFIBUS DP

EtherCAT

PROFINET

Note) Enclosure is IP40 when the communication connector is D-sub.

SI unit output polarity

32

16

32

16

32

16

32

16

32

16

32

16

32

16

M12

M12

D-sub Note)

M12

M12

EtherNet/IP™ M12

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

Source/PNP (Negative common)Sink/NPN (Positive common)

QANQA

QBNQB

NANNA

NBNNB

NCNNC

NDNND

VANVA

VBNVB

DANDA

DBNDB

FANFA

FBNFB

EANEA

EBNEB

Communication protocol

Compact design Compact design for space saving

Number of outputs Each 32/16 digital output type available in the series

Enclosure IP67 (For units with D-sub connector, and when connected with S0700 manifolds, it is IP40.)

Output polarity Each negative common (PNP) / positive common (NPN) type available in the series

Internal terminating resistorON/OFF switching is possible with an internal terminating resistor for communication.(Only for units compatible with M12 PROFIBUS DP, CC-Link communication connectors)

SY3000/5000 VQC1000/2000/4000 S0700 SV1000/2000/3000

DD

DD

How to Order SI Units

PR1EX260 S

Note)

Note) The SY3000/5000, VQC1000/2000/4000, and S0700 are not yet UL-compatible.

CC-Link

®

RoHS

ProtocolSymbol Number of outputs Communication connector Manifold symbol

Series EX260SI Unit/For Output

2066

Page 17: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

SI Unit Specifications

Model EX260-SPR1/3 EX260-SPR2/4 EX260-SPR5/7 EX260-SPR6/8 EX260-SDN1/3 EX260-SDN2/4 EX260-SMJ1/3 EX260-SMJ2/4

125 k/250 k/500 kbps 156 k/625 k/2.5 M/5 M/10 Mbps

M12Built-in

—22.8 to 26.4 VDC

11 to 25 VDC100 mA or less

Applicablesystem

I/O occupation area (Inputs/Outputs)

Communication speed

Power supplyfor controlPower supply for output

Communication connector specificationTerminating resistor switch

Power supply for communication

Output

Environmental resistance

StandardsWeight

Mounting screwAccessories

IP67 IP40 IP67–10 to 50°C

35 to 85%RH (No condensation)500 VAC for 1 minute between terminals and housing

10 MΩ or more (500 VDC measured via megohmmeter) between terminals and housingCE marking, UL (CSA) compatible

200 g2 pcs.

24 VDC

Power supply voltageInternal current consumptionPower supply voltagePower supply voltageInternal current consumption

Protocol

Version Note 1)

Configuration file Note 3)

Supplied current

Output type

Number of outputs

LoadSupplied voltage

EnclosureOperating temperature rangeOperating humidity rangeWithstand voltageInsulation resistance

Seal cap (for M12 connector socket)

Source/PNP(Negative common)

Sink/NPN(Positive common)

Source/PNP(Negative common)

Sink/NPN(Positive common)

Source/PNP(Negative common)

Sink/NPN(Positive common)

SPR1: 32 pointsSPR3: 16 points

SPR2: 32 pointsSPR4: 16 points

SPR5: 32 pointsSPR7: 16 points

SPR6: 32 pointsSPR8: 16 points

SDN1: 32 pointsSDN3: 16 points

SDN2: 32 pointsSDN4: 16 points

SPR1: 0/32SPR3: 0/16

SPR2: 0/32SPR4: 0/16

SPR5: 0/32SPR7: 0/16

SPR6: 0/32SPR8: 0/16

SDN1: 0/32SDN3: 0/16

SDN2: 0/32SDN4: 0/16

SMJ1: 32/32SMJ3: 32/32(1 station, remote I/O stations)

SMJ2: 32/32SMJ4: 32/32(1 station, remote I/O stations)

SPR1: Max. 2.0 ASPR3: Max. 1.0 A

SPR2: Max. 2.0 ASPR4: Max. 1.0 A

SPR5: Max. 2.0 ASPR7: Max. 1.0 A

SPR6: Max. 2.0 ASPR8: Max. 1.0 A

SDN1: Max. 2.0 ASDN3: Max. 1.0 A

SDN2: Max. 2.0 ASDN4: Max. 1.0 A

EX9-AWTS (1 pc.) — EX9-AWTS (1 pc.)

D-sub M12None Built-in

Volume 1(Edition 3.5)Volume 3(Edition 1.5)

9.6 k/19.2 k/45.45 k/93.75 k/187.5 k/500 k/1.5 M/3 M/6 M/12 Mbps

21.6 to 26.4 VDC100 mA or less

—— —

21.6 to 26.4 VDC100 mA or less

PROFIBUS DP DeviceNet™ CC-Link

DP-V0 Ver.1.10

—GSD file EDS file

Source/PNP(Negative common)

Sink/NPN(Positive common)

SMJ1: 32 pointsSMJ3: 16 points

SMJ2: 32 pointsSMJ4: 16 points

SMJ1: Max. 2.0 ASMJ3: Max. 1.0 A

SMJ2: Max. 2.0 ASMJ4: Max. 1.0 A

Solenoid valve with protective circuit for surge voltage of 24 VDC/1.5 W or less (SMC)

Model EX260-SEC1/3 EX260-SEC2/4 EX260-SPN1/3 EX260-SPN2/4 EX260-SEN1/3 EX260-SEN2/4

Applicablesystem

I/O occupation area (Inputs/Outputs)Communication speed Power supplyfor controlPower supply for output

Communication connector specificationTerminating resistor switch

Power supply for communication

Output

Environmental resistance

StandardsWeight

Mounting screwAccessories

IP67–10 to 50°C

35 to 85%RH (No condensation)500 VAC for 1 minute between terminals and housing

10 MΩ or more (500 VDC measured via megohmmeter) between terminals and housingCE marking, UL (CSA) compatible

200 g2 pcs.

24 VDC

Power supply voltageInternal current consumptionPower supply voltagePower supply voltageInternal current consumption

Protocol

Version Note 1)

Configuration file Note 3)

Supplied voltage

Output type

Number of outputs

Load

Supplied voltage

EnclosureOperating temperature rangeOperating humidity rangeWithstand voltageInsulation resistance

Seal cap (for M12 connector socket)

Source/PNP(Negative common)

Sink/NPN(Positive common)

Source/PNP(Negative common)

Sink/NPN(Positive common)

Source/PNP(Negative common)

Sink/NPN(Positive common)

SEC1: 32 pointsSEC3: 16 points

SEC2: 32 pointsSEC4: 16 points

SPN1: 32 pointsSPN3: 16 points

SPN2: 32 pointsSPN4: 16 points

SEN1: 32 pointsSEN3: 16 points

SEN2: 32 pointsSEN4: 16 points

SEC1: 0/32SEC3: 0/16

SEC2: 0/32SEC4: 0/16

SPN1: 0/32SPN3: 0/16

SPN2: 0/32SPN4: 0/16

SEN1: 16/32SEN3: 16/16

SEN2: 16/32SEN4: 16/16

SEC1: Max. 2.0 ASEC3: Max. 1.0 A

SEC2: Max. 2.0 ASEC4: Max. 1.0 A

SPN1: Max. 2.0 ASPN3: Max. 1.0 A

SPN2: Max. 2.0 ASPN4: Max. 1.0 A

SEN1: Max. 2.0 ASEN3: Max. 1.0 A

SEN2: Max. 2.0 ASEN4: Max. 1.0 A

EX9-AWTS (1 pc.)

Volume 1(Edition 3.8)Volume 2(Edition 1.9)

21.6 to 26.4 VDC100 mA or less

22.8 to 26.4 VDC——

M12None

10 M/100 Mbps Note 2)100 Mbps Note 2)

EtherCAT Note 2) EtherNet/IP™ Note 2)

Conformance Test Record V.1.1

XML file

PROFINET Note 2)

PROFINET SpecificationVersion 2.2

GSD file EDS file

Solenoid valve with protective circuit for surgevoltage of 24 VDC/1.5 W or less (SMC)

Solenoid valve with protective circuit for surgevoltage of 24 VDC/1.0 W or less (SMC)

Solenoid valve with protective circuit for surgevoltage of 24 VDC/1.5 W or less (SMC)

Note 1) Please note that the version is subject to change.Note 2) Use a CAT5 or higher transmission cable for EtherCAT, PROFINET, EtherNet/IP™.Note 3) Each file can be downloaded from the SMC website, http://www.smcworld.com

For Output Series EX260

2067

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX260

Page 18: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

D-sub communication connector typeM12 communication connector type

90.9

28.2

102.

4 90.9

102.

4

28.221 20.6 16.4 9

76.5

28.75 29.25 9

76.5

SI Unit Dimensions

Part no.

Communication protocol

EX260-SPR1/-SPR2 -SPR3/-SPR4

PROFIBUS DP

5 pins, socket, B code

5 pins, plug, B code

5 pins, plug, A code

Note) The setting switch varies depending on the model. Refer to the operation manual for details. Please download it via the SMC website, http://www.smcworld.com

EX260-SDN

DeviceNet™

5 pins, socket, A code

5 pins, plug, A code

4 pins, plug, A code

EX260-SMJ

CC-Link

EX260-SECEX260-SPNEX260-SEN

EtherCATPROFINET

EtherNet/IP™

M3

Communication connector (M12) BUS OUT

Communication connector (M12) BUS IN

Ground terminal

Power connector (M12)

<Setting switch>• Address switch• Communication speed switch• Terminating resistor switch• Others

<LED indication>• Communication state• Unit power supply state• Valve power supply state

Part no.

Communication protocol

EX260-SPR5/-SPR6/-SPR7/-SPR8PROFIBUS DP

M3

9 pins, socket

5 pins, plug, A code

Ground terminal

Communication connector (D-sub) BUS IN/OUT

Power connector (M12)

D-sub communication connector type

Functions of SI Unit Parts

<Connector>M12 communication connector type

<LED indication and setting switch>

5 pins, socket, A code

4 pins, plug, A code

5 pins, plug, B code

4 pins, socket, D code

4 pins, socket, D code

5 pinsNote1), 4 pinsNote2), plug, A code

Note 1) For EtherCAT, PROFINETNote 2) For EtherNet/IP™

Series EX260

2068

Page 19: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

WhiteOrangeWhite

Green

Accessories

q Communication cable with connector

For SI units compatible with PROFIBUS DP, DeviceNet™, CC-Link

For SI units compatible with EtherCAT, PROFINET, EtherNet/IP™

Refer to page 2153 for details. 020EX9 AC ENCable length (L)

1000 [mm] 2000 [mm] 3000 [mm] 5000 [mm]10000 [mm]

010020030050100

PSRJ

M12 plug (straight) ⇔ RJ-45 connectorPSRJ

1

3 4

2

Plug connectorpin arrangement

D codeConnections (Straight cable)

M12 RJ-45

ø6.

7

47.3 45L

Plug connectorpin arrangement

12345678

Terminalno.1234

12345678

Terminalno.

Shield

Pair

Pair

Core wire colors

Connector specification

For SI units compatible with EtherCAT, PROFINET, EtherNet/IP™

PCA 1446566

For SI units compatible with EtherCAT, PROFINET, EtherNet/IP™

PCA 1446553

5000 [mm]1446566Cable length

Fieldwireable connector

(ø6.

5)

50500047.3

ø14

.8

Plug connectorpin arrangement

D code

12

3 4

M12SPEEDCON

ø17

.5

ø19

≈ 61

Width acrossflats 16

M12

For Output Series EX260

Plug connectorpin arrangement

D code

12

3 4

12

34

White: RD+

Blue: RD–

Yellow: TD+

Orange: TD–

Connections

Terminalno. Wire guide color

Width across flats 13

2069

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX260

Page 20: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

w Power cable with connector (for SI units)

Accessories

EX500 AP

2

4 3

Socket connectorpin arrangement

A code

Socket connectorpin arrangement

A code

1

12

34

5

Terminalno.

Core wire colors

M12

ø14

.9

4834

18

L

ø6

30 5

50

Connections (PROFIBUS DP/EtherCAT)

Cable length (L)1000 [mm]5000 [mm]

010050

Connector specificationStraightAngle

SA

S050

For SI units compatible with PROFIBUS DP, DeviceNet™, EtherCAT, PROFINET, EtherNet/IP™

e Seal cap: For M12 connector socket

EX9 AW

Use this on ports that are not being used for communication connector (M12 connector socket).Use of this seal cap maintains the integrity of the IP67 enclosure.Note) Tighten the seal cap with the prescribed tightening torque. (For M12: 0.1 N·m)

TSConnector type

For M12 connector socket (10 pcs.)For M12 connector socket

M12 x 1

14

10.2

14

Brown: 24 VDC +10%/–5% (Solenoid valve power supply)White: 0 V (Solenoid valve power supply)

Blue: 24 VDC ±10% (Control power supply)Black: 0 V (Control power supply)

Gray: Not connected

12

34

5

Terminalno.

Core wire colors

Connections (DeviceNet™, EtherNet/IP™)

Brown: Not connected Note 1), 24 VDC ±10% (Control power supply) Note 2)White: 24 VDC +10%/–5% (Solenoid valve power supply) Blue: Not connected Note 1), 0 V (Control power supply) Note 2)Black: 0 V (Solenoid valve power supply)

Gray: Not connected

Straight connector type

For SI units compatible with CC-Link

Straight connector type

2

4 3

51

M12

31.3

28.3

30 5

50L

ø6

Angle connector type

TS

5

EX9 AC 1Cable length (L)

1000 [mm]3000 [mm]5000 [mm]

010030050

050

SPEEDCON

SPEEDCON

PCACable length (L)

1500 [mm]3000 [mm]5000 [mm]

140180414018051401806

1401804

PCACable length (L)

1500 [mm]3000 [mm]5000 [mm]

140180714018081401809

1401807

2

4 3

5 1

Socket connectorpin arrangement

B code

M12 48.1

L

30

50

5

ø6.

4

Connections1

23

45

Terminalno.

Cable corewire colors

4 3

21

4 3

21

ø14

.8

M12SPEEDCON

M12SPEEDCON

ø14

.8

44.5 L 50

50L44.5

ø5.

0±0.

15ø

5.0±

0.15

5

5

Socket connectorpin arrangement

A code

Socket connectorpin arrangement

B code

Note 1) For DeviceNet™Note 2) For EtherNet/IP™

Brown: 24 VDC +10%/–5% (Solenoid valve power supply)White: 0 V (Solenoid valve power supply)

Blue: 24 VDC ±10% (Control power supply)Black: 0 V (Control power supply)

Gray: Not connected

Series EX260

2070

Page 21: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

Design/Selection

1. Use this product within the specification range.Using beyond the specified specifications range can causefire, malfunction, or damage to the system.Check the specifications before operation.

2. When using for an interlock circuit:• Provide a multiple interlock system which is

operated by another system (such as mechanical protection function).

• Perform an inspection to confirm that it is working properly.

This may cause possible injury due to malfunction.

WarningMounting

4. When lifting a large size manifold solenoid valve unit, take care to avoid causing stress to the valve connection joint.The connection parts of the unit may be damaged. Because the unit may be heavy, carrying and installation should be performed by more than one operator to avoid strain or injury.

5. When placing a manifold, mount it on a flat surface.Torsion in the whole manifold can lead to trouble such as air leakage or defective insulation.

Wiring

1. Check the grounding to maintain the safety of the reduced wi r ing sys tem and for an t i -no ise performance.Provide a specific grounding as close to the unit as possible to minimize the distance to grounding.

2. Avoid repeatedly bending or stretching the cable and applying a heavy object or force to it.Wiring applying repeated bending and tensile stress to the cable can break the circuit.

3. Avoid miswiring.If miswired, there is a danger of malfunction or damage to the reduced wiring system.

4. Do not wire while energizing the product.There is a danger of malfunction or damage to the reduced wiring system or output device.

5. Avoid wiring the power line and high pressure line in parallel.Noise or surge produced by signal line resulting from the power line or high pressure line could cause malfunction.Wiring of the reduced wiring system or output device and the power line or high pressure line should be separated from each other.

6. Check the wiring insulation.Defective insulation (contact with other circuits, improper insulation between terminals, etc.) may cause damage to the reduced wiring system or output device due to excessive voltage and current.

7. When a reduced wiring system is installed in machinery/equipment, provide adequate protection against noise by using noise filters, etc.Noise in signal lines may cause malfunction.

1. When applicable to UL, use a Class 2 power supply unit conforming to UL1310 for direct current power supply.

2. Use this product within the specified voltage range.Using beyond the specified voltage range is likely to cause the units and connecting devices to be damaged or to malfunction.

3. Do not install a unit in a place where it can be used as a foothold.Applying any excessive load such as stepping on the unit by mistake or placing a foot on it, will cause it to break.

4. Keep the surrounding space free for maintenance.When designing a system, take into consideration the amount of free space needed for performing maintenance.

5. Do not remove the name plate.Improper maintenance or incorrect use of operation manual can cause failure and malfunction. Also, there is a risk of losing conformity with safety standards.

1. When handling and assembling units:• Do not apply excessive force to the unit when

disassembling.The connecting portions of the unit are firmly joined with seals.

• When joining units, take care not to get fingers caught between units.Injury can result.

2. Do not drop, bump, or apply excessive impact. Otherwise, the unit can become damaged, malfunction, or fail to function.

3. Observe the tightening torque range.Tightening outside of the allowable torque range will likely damage the screw.

IP67 cannot be guaranteed if the screws are not tightened to the specified torque.

Mounting

Series EX260Specific Product Precautions 1Be sure to read before handling. Refer to front matter 53 for Safety Instructions, Pages 3 to 8 and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions. The Operation Manual can be downloaded from the SMC website,http://www.smcworld.com

Caution

Caution

Caution

Caution

2071

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX260

Page 22: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

Wiring

Operating Environment

1. Do not use in an atmosphere containing an inflammable gas or explosive gas.Use in such an atmosphere is l ikely to cause a fire or explosion. This system is not explosion-proof.

Operating Environment

2. Provide adequate protection when operating in locations such as the following.Failure to do so may cause damage or malfunction.The effect of countermeasures should be checked in individual equipment and machine.1) Where noise is generated by static electricity, etc.2) Where there is a strong electric field3) Where there is a danger of exposure to radiation4) When in close proximity to power lines or high voltage lines

3. Do not use in an environment where oil and chemicals are used.Operating in environments with coolants, cleaning solvents, various oils or chemicals may cause adverse effects (damage, malfunction) to the unit even in a short period of time.

4. Do not use in an environment where the product could be exposed to corrosive gas or liquid.This may damage the unit and cause it to malfunction.

5. Do not use in locations with sources of surge generation.Installation of the unit in an area around the equipment (electromagnetic lifters, high frequency induction furnaces, welding machine, motors, etc.), which generates the large surge voltage could cause to deteriorate an internal circuitry e lement of the uni t or resul t in damage. Implement countermeasures against the surge from the generating source, and avoid touching the lines with each other.

6. The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in your system.

7. Keep dust, wire scraps and other extraneous material from getting inside the product.This may cause malfunction or damage.

8. Mount the unit in such locations, where no vibration or shock is affected.This may cause malfunction or damage.

9. Do not use in places where there are cyclic temperature changes.In case that the cycl ic temperature is beyond normal temperature changes, the internal unit is likely to be adversely effec-ted.

10. Do not use in direct sunlight.Do not use in direct sunlight. It may cause malfunction or damage.

11. Use this product within the specified ambient temperature range.This may cause malfunction.

12. Do not use in places where there is radiated heat around it.Such a place is likely to cause malfunction.

1. Select the proper type of enclosure according to the environment of operation.IP67 is achieved when the following conditions are met.1) Provide appropriate wiring between all units using electrical

wiring cables, communication connectors and cables with M12 connectors.

2) Suitable mounting of each unit and manifold valve.3) Be sure to mount a seal cap on any unused connectors.If using in an environment that is exposed to water splashes, please take measures such as using a cover.When the enclosure is IP40, do not use in an operating environment or atmosphere where it may come in contact with corrosive gas, chemical agents, seawater, water, or water vapor. When connected to the EX260-SPR5/6/7/8, manifold enclosure is IP40.

Series EX260Specific Product Precautions 2Be sure to read before handling. Refer to front matter 53 for Safety Instructions, Pages 3 to 8 and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions. The Operation Manual can be downloaded from the SMC website, http://www.smcworld.com

Caution

Caution

Caution

Warning

8. When connecting wires of output device, prevent water, solvent or oil from entering inside the connector section. This can cause damage, equipment failure or malfunction.

9. Avoid wiring patterns in which excessive stress is applied to the connector.This may cause malfunction or damage to the unit due to contact failure.

10. Select connectors that are ø16 or less if mounting manifolds directly using fieldwireable connectors for SI unit power supply wiring.Using large diameter connectors causes interference with the mounting surface.The following cables with connectors are recommended.

For EX260-SPR/-SDN/-SEC/-SPN/-SEN<Cable with connector> EX500-AP- PCA-1401804/-1401805/-1401806

For EX260-SMJ<Cable with connector> EX9-AC-1 PCA-1401807/-1401808/-1401809

2072

Page 23: For Output - Pneumatic Automação Industrial · 2017. 1. 25. · VQ2000/4000/5000 Series EX124 VQ2000/4000/5000 Series EX126 SV1000/2000/3000 SY3000/5000 VQC1000/2000/4000 Note)

Adjustment/Operation

Warning1. Do not perform operation or setting with wet hands.

There is a risk of electrical shock.

Maintenance

1. Do not disassemble, modify (including circuit board replacement) or repair this product.Such actions are likely to cause injuries or breakage.

2. When an inspection is performed,• Turn off the power supply.• Stop the air supply, exhaust the residual pressurein

piping and verify that the air is released before performing maintenance work.Unexpected malfunction of system components and injury can result.

TrademarkDeviceNet™ is a trademark of ODVA.EtherNet/IP™ is a trademark of ODVA.EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

1. Use a watchmakers’ screwdriver with thin blade for the setting of each switch of the SI unit.When setting the switch, do not touch other unrelated parts.This may cause parts damage or malfunction due to a short circuit.

2. Provide adequate setting for the operating conditions.Failure to do so could result in malfunction.Refer to the operation manual for setting of the switches.

3. For details on programming and address setting, refer to the manual from the PLC manufacturer.The content of programming related to protocol is designed by the manufacturer of the PLC used.

4. For the EX260-SPN, the side of the SI unit may become hot.It may cause burns.

1. When handling and replacing the unit:• Do not apply excessive force to the unit when

disassembling.The connecting portions of the unit are firmly joined with seals.

• When joining units, take care not to get fingers caught between units.Injury can result.

2. Perform periodic inspection.Unexpected malfunction in the system composition devices is likely to occur due to malfunction of machinery or equipment.

3. After maintenance, make sure to perform an appropriate functionality inspection.In cases of abnormality such as faulty operation, stop operation. Unexpected malfunction in the system composition devices is likely to occur.

4. Do not use benzene and thinner for cleaning units.Damage to the surface or erasure of the display can result.Wipe off any stains with a soft cloth.If the stain is persistent, wipe off with a cloth soaked in a dilute solution of neutral detergent and wrung out tightly, and then finish with a dry cloth.

Other

1. Refer to the catalog of each series for Common Precautions and Specific Product Precautions on manifold solenoid valves.

Series EX260Specific Product Precautions 3Be sure to read before handling. Refer to front matter 53 for Safety Instructions, Pages 3 to 8 and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions. The Operation Manual can be downloaded from the SMC website,http://www.smcworld.com

Caution

Caution

Caution

Warning

2073

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510PCAEX

EX260