17
Follow in your AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Follow in your AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

  • Upload
    shayna

  • View
    28

  • Download
    1

Embed Size (px)

DESCRIPTION

Follow in your AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27. Cables and there function. Cables are mostly used to control engine and flight controls through their normal range of movement. Cables are made of high carbon steel or corrosion resistant steel wire. - PowerPoint PPT Presentation

Citation preview

Page 1: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Follow in your

AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Page 2: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Cables and there function

Page 3: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Cables are mostly used to control engine and flight controls through their normal range of movement

Page 4: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Cables are made of high carbon steel or corrosion resistant steel wire

Page 5: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

A flexible cable is generally made up of a number of strands or group of strands of wire. When a group of stands is used they are woven around the centre strand or core to complete the cable. A flexible cable that is a 7 by 7 would be 6 cables wrapped around a centre cable (or core). Each of these 7 cables would be made up of 7 smaller cables in same way (6 around 1) .

Page 6: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Non -flexible cables have no centre cable so they would be described as a 1 by 19, which is 19 wires in a bundle A nylon cable is coated with nylon and resists breaking down . It generally has a longer service life

Page 7: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Most cable wear occurs where the cable bends (pulley and is caused by friction between the strands. When dealing with an unprotected cable this can be aggravated by a dirt or grit.

On long straight cable runs constant vibration can work harden the cable and cause it to become brittle and fray.

Page 8: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Replace the cables if they become distorted , worn , or corroded.. If you can not replace the cable then an approved repair can take place until a replacement part can be installed. No splice comes closer than 2 inches to a pulley or fairlead.

SHOW ON THE BOARD HOW WHEN MAKING A REPAIR THE REPAIR CAN NOT INTERFERE WITH THE CABLE RUN.

Page 9: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Always use the proper tools and manuals when attempting a swag repair. Measurement of the swagged fitting can be done with a no -go gauge or a micrometer. The finished swag fitting must meet manual standards (see page 7- 31) and not be out of round. Check the proof load of the finished product by applying 60 percent of the total allowable load.

TALK ABOUT NICO PRESS AND THE WAY IT IS USED

Page 10: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Use the charts on pg 7-34 to determine the size of thimble to use .When making a eye splice (pg 7-33) always make sure the cable extends beyond the thimble as the thimble will elongate. When using a lap splice two thimbles are used to give adequate strength to the cable run

Page 11: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Cable inspection should be done when ever required by the appropriate manuals. Check the cable for frays , broken strands, corrosion, or other signs of wear. Give special attention to areas where the cable turns or bends as this is a high stress area.

Page 12: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Using a rag or cotton gloves while checking for frays will save you hands from getting metal splinters. In some instances a broken wire may not be sticking out of the cable and may only appear as a hairline crack on the cable. At this point you can use a magnifying glass and also bend or twist the cable to see if the frayed wire pops out. See pg 7-37 figure 7-19 for a view of a cable that may have breaking down internally from fatigue .

Page 13: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Always inspect the cable through it’s full travel. Have someone move the cable from the cockpit as you are inspecting it , pay special attention to problem areas like pulleys, area’s near washrooms and battery compartments

Page 14: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Check pulleys for excessive wear, flat spots or dirt. Make sure it moves freely and the bearing has proper lubrication.The pulley must also be aligned to prevent the cable from riding on the flanges . Some times a dry mollycoat spray is the best to use as it doesn’t attract dirt. See chart 7-20 on pg 7-38 for examples.

Page 15: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Check any wire splices if they exist for defects . Ensure the wire appears to be positioned properly in the splice

Page 16: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

Part of the inspection with cables includes that they are properly tensioned. Use the appropriate manuals to check the tension on each cable run. When taking tensions ensure the cables are at room temp

Page 17: Follow in your  AIRCRAFT INSPECTION, REPAIR & ALTERATIONS MANUAL – PAGE 7-27

THE END