Fire Alarm System Fire Alarm System WUXI BRIGHTSKY ELECTRONIC CO., LTD WUXI BRIGHTSKY ELECTRONIC CO., LTD

Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

Fire AlarmSystemFire AlarmSystem

WUXI BRIGHTSKY ELECTRONIC CO., LTDWUXI BRIGHTSKY ELECTRONIC CO., LTD

Page 2: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

As a major manufacturer of fire alarm products in China,

Wuxi Brightsky Electronic Co., Ltd (WBEC) is seeking to establish

a global presence in the fire alarm equipment industry.

As an ISO 9001 (2000) company, WBEC has established

a solid reputation for quality fire alarm products and is one of

China's largest fire alarm equipment manufacturers. In house

ERP management software, attention to corporate management

and employee training programs reflect WBEC's commitment

to customer satisfaction. Always on the cutting edge of technology,

WBEC invests significant resources in it's R & D activities,

such as the innovative 5i Series intelligent fire detection and alarm

system product.

Page 3: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

JB-QB-5Si Fire Control PanelJB-QB-5Si Fire Control Panel

General

Characteristics

Main technical parameter

JB-QB-5Si type fire control panel (linkage operation type) adopts wall-mounted form, which has fire alarm, fire fighting linkage operation and single zone gas fire extinguishing control function simultaneously. It adopts full Chinese version LCD display and its menu operation adopts full Chinese graphic windows, which provide the customer with a simple, clear and convenient usage. It has six sets multi-line direct output external control contacts which is equipped with corresponding button switches.Even under the condition of CPU malfunction, it can implement operation towards external control devices. Alarm controller can be connected with 5i type detector. The capacity is defined as follows: 5i type detector can have 240 addresses which include linkage operation points.

Large LCD displayGraphic menu operationSupport detector isolation functionSupport room number switching and English character inputOn-site linkage operation relationship programmingRealize true bus line (2-wire); detector and module shares alarm bus line Be able to be connected with 5i detector .

¡Ü

AC 220V (+10%,-15%) 50HZDC 24V , 2.3AHMonitoring Status: 2.4W; Alarm Status: 10WIntelligent type detector: 240 address codesSix One <20 S (single point continuous querying if the condition is abnormal) 1500 M5i type detector: 2-wire, non-polarity5i type module: 2-wire, polarity, Signal line adopts RVS-2 1.5mm2 Double colors, couple hunk, multi-prong plastic soft line; power source line adopts RVS-2 2.5mm2 Double colors, couple hunk, multi-prong plastic soft lineKA1 and KA2 are opened after first fire alarmYA1 and YA2 are opened after 2-minute delay after fire alarmDC 30V , 2A.

Main power sourceBack-up power sourceWork consumptionBasic monitoring capacityDirect external control contactFire extinguishing control contactPolling cycleSingnal transportation distanceWiring method

Contact capacity

Line conductor

External control contact

Page 4: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

JB-QB-5Si Fire Control Panel

Application and Installation

¡Ü ¡Á

Operation temperatureRelative humidityConfiguration dimensionInstallation formWeight

Linkage operation programming quantitiesRoom number switching capacityRoom number switching maximum characters quantities

This controller is suitable to be installed in the small scale project, such as Karaok dancing room . It can also be used as single zone fire extinguishing controller.This controller can be connected with FXP5i fire alarm display panel/repeater to become an external extension for alarm position indication. Fire controller and fire display panel are connected by four-wire bus. System design is shown as following in Figure 1.

Black box record quantities

0 ~55 95%440 340 82 (height width thickness) mm3

Wall-mountedAbout 12KgCan keep recent 500 pcs records which include open, close manchine, reset, fire alarm, fault and linkage operation command.150 pcs ( "or" 1, "or "2 and "and" logic have 50 pcs respectively).240 pcs 14 pcs English characters or 7 pcs Chinese characters.

Connecting

Reserve

Rectifier&Transformer

Page 5: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

JB-QB-5Si Fire Control Panel

JTY-GD-5i Optical Smoke Detector

General

Technical Standard: Type:Operation voltage: Monitoring current:Alarm current:Operation temperature:Relative humidity: Maximum air flow speed:Configuration dimension:Weight: Color:

Super-thin profile and low power consumption designEquipped with CPU central processor and automatically judge fire alarm2-wire non-polarity designWeather-proof and suitable to use in high interference placeUse coder to write address code

5i series fire fighting electronics product is one set advanced intelligent fire alarm information integrated processing control system. This system bus line devices all have CPU central processor. According to preset alarm threshold value, the detector can automatically implement fire alarmanalysis and judge. It adopts 2-wire addressable electric current pulse wide transportation technology between the control panel and the detector to guarantee communication accuracy. It will minimize fault alarm rate.

Comply with GB4715-93 requirement:Analog, intelligent;24V DC ; 350uA; 2mA;-10 ~+50 ; 95%; 5m/sec; 91 35mm; About 100g;Cream white;

5i Series Fire Detectors5i Series Fire Detectors

Characteristics

Main Technical Parameter

Page 6: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

Application and installation

Optical smoke detector can be used in the strict environment condition. It is normally installed in the office, guest room, hall, corridor, computer room, warehouse, switch control room and power transformer room etc in various building floors.Optical smoke detector installation mainly comprises 86 type pre-embedded box, base and detector.Detector configuration dimension, installation method and base wiring is shown as follows.

JB- QB- 5i»ðÔÖ±¨¾¯¿ØÖÆÆ÷

£¨Áª¶¯ÐÍ£©

T+inT-in T+outT-out

LI5i

T+T-

Fire Alarm Bus Out

Detctor Base

21

21

21

21

Fire Alarm BusT+

T-

T+T- T+T-

Confirmation Light86Type Pre-embedded Box

44

91

Secton Tube

Detector

DB5i Base

Page 7: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

JB-QB-5Si Fire Control Panel

Characteristics

Technical Standard:Type:Operation voltage:Monitoring current:Alarm current:Configuration dimension:Operation temperature:Relative humidity:Weight:Color:

Equipped with CPU central processor; Automatically judge fire alarm2-wire non-polarity designElectronic heat thermistor, high-sensitivity and reliabilitySuper-thin profile and the height is only 35mm.Use coder to write address codes.

This detector will respond after environmental temperature reaches to some warm value, which is suitable to be used in the large temperature change context in the fire accident. The detector has coded circuit and can be directly installed in DB5i standard base, which is connected with fire alarm controller via 2-wire bus.Detector installation and configuration dimension is shown as follows. Base wiring is same with optical smoke detector.

Comply with GB4716-93 requirement;Analog, intelligent, ceiling-mounted, fixed point type;24V DC ; 350mA; 2mA; 91 35mm;-10 ~ +50 ; 95%;About 125g;Cream white;

JTW-ZD-5i Heat DetectorJTW-ZD-5i Heat Detector

Main Technical Data

Application and Installation

44

Sect on Tube

86TypePr e- embedded Box

DB5i Base

Det ect or

Conf i r mat i on Li ght

Ther mi st or91

Page 8: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

JB-QB-5Si Fire Control Panel

Characteristics

¡Á ¡Á

Operation voltage;Monitoring current;Alarm current;Alarm method;Contact capacity;Operation temperature;Relative humidity;Configuration dimension;Weight;Color;

2-wire bus transmit manual fire alarm signal with fire alarm controllerReliable and wide range applicationUse coder to write coding addressButton glass is modified to push down, but not smash glassSuper-thin profile design

Manual call point is an designed to send out fire accident signal manually and inform fire alarm message. It is normally installed at the entrance of stair, corridor or place where persons often pass by. When fire accident is confirmed manually, please push down button glass and that will send out alarm signal to fire alarm controller. At the same time, control contacts of K1¡¢K2 are closed, which can control sounder initiation.J-SAP-5i manual call point out wiring method is shown in Figure as follows.

24V DC ; 250mA; 2mA;Push down glass;DC27V 1A-10 ~+50 ; 95%;82 82 32mm (height width thickness);About 200g;Red

J-SAP-5iManual Call PointJ-SAP-5iManual Call Point

Main Technical Data

Application and Installation

Page 9: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

JB- QB- 5i»ðÔÖ±¨¾¯¿ØÖÆÆ÷

£¨Áª¶¯ÐÍ£©

J-SAP-5i

T+T-

Fire Alarm BusT+

T-

J-SAP-5i

Red Wire Green Wire Red Wire Green Wire

61

82

82

Fire AlarmIndicate Light

R

11 20

Head Cover

Middle Cover

Plate Box

Secton Tube

86 TypePre-embedded Box

Plate Box

Manual AlarmButton

1.5Meter

Ground

Page 10: Fire Alarm System - JR international BRIGHTSKY English Catalogue.pdfJB-QB-5Si Fire Control Panel JB-QB-5Si Fire Control Panel General Characteristics Main technical parameter JB-QB-5Si

AddressLuoshe, Huishan District, Wuxi City, Jiangsu Province, P.R.ChinaTel: +86 (0) 510 334 00 37Fax: +86 (0) 510 331 55 17Post Code: 214187Internet: www.bsky-wx.comKey Contact: Mr Walter ZongPosition: Chief Operating OfficerE-mail: [email protected]

Internationals sales Office:Farhang Safety Equipment Co., LLCTel: 00971-4-2979442; 00971-4-2216032Fax: 00971-4-2979448P.O.Box: 86416, Dubai-U.A.E.Contact: Mr Ali Farhang, Managing DirectorE-Mail: [email protected]

Tan Toan Quoc Trade & Stock Company:35/44/4/6, Vuon Lai Street, 18 Ward, Tan Binh District, Ho Chi Minh City, VietnamFax: 84 8 9781992Tel: 84 8 9782147E-Mail: [email protected] [email protected]: Mr To Tuan Anh, Director