38

Evaluation Data - RFE2500 Series - product.tdk.com

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Evaluation Data - RFE2500 Series - product.tdk.com
Page 2: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

1. Evaluation Method PAGE1-1. Circuit used for determination T-1~5

(1) Steady state data (2) Warm up voltage drift & long term stability (3) Over voltage protection (OVP) characteristics (4) Over current protection (OCP) characteristics (5) Output rise characteristics (6) Output fall characteristics (7) Dynamic line response characteristics (8) Dynamic load response characteristics (9) Inrush current characteristics (10) Leakage current characteristics (11) Output ripple and noise waveform (12) Standby current

1-2. List of equipment used T-6

2. Characteristics2.1 Steady state data

(1) Regulation - line and load, Temperature drift, Start-up voltage T-7~9T-10T-11T-12T-13T-14

T-15~16T-17~18T-19~20T-21~22

T-23T-24

T-25~27T-28~29T-30~31

T-32T-33

T-34~35T-36

2.15 Leakage current characteristic2.16 Output ripple and noise waveform2.17 Standby current

2.9 Hold up time characteristics2.10 Dynamic line response characteristics2.11 Dynamic load response characteristics2.12 Response to brown out characteristics

INDEX

2.14 Input current waveform

(2) Output voltage and ripple noise voltage vs. Input voltage (3) Efficiency and Input current vs. Output current2.2 Warm up voltage drift characteristics 2.3 Over voltage protection (OVP) characteristics2.4 Over current protection (OCP) characteristics 2.5 Output rise characteristics 2.6 Output fall characteristics2.7 Output rise characteristics with ON/OFF CONTROL 2.8 Output fall characteristics with ON/OFF CONTROL

2.13 Inrush current waveform

TDK-Lambda

Page 3: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

1.EVALUATION METHOD

1-1.Circuits used for determination

(1) Steady state dataDigital power meter

SW. 230VAC

Controlled temp.chamber

(2) Warm up voltage drift & temperature stability

Digital power meter

SW. 230VAC

Controlled temp.chamber

WA

V

P.S.Electronic

loadV

++Vo

--Vo

V_

_~

~~Shunt Res.

Signal Rtn

-sShunt Res.

Enable

+12Vaux

+s

Electronicload

V_

V_

AC

AC

+

-

Gnd

WA

V

P.S.

V

++Vo

--Vo

V_

_~

~~

Shunt Res.

Signal Rtn

-sShunt Res.

Enable

+12Vaux

+s

Electronicload

Electronicload

V_

V_

AC

AC

+

-

Gnd

0~5V

Vprog.

-S

Osc

illo

scop

eO

scill

osc

op

eO

sci

llosco

pe

Osc

illo

scop

e

0~5

Vprog.

-S

AC PowerSupply

AC PowerSupply

SW.

SW.

TDK-Lambda T-1

Page 4: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

(3) Over Voltage Protection (OVP) characteristics

Digital power meter

230VAC

(4) Over Current Protection (OCP) characteristics

Same as item (1)

(5) (6) Output Rise & Fall Characteristics

Digital power meter

230VAC

Controlled temp.chamber

WA

V

P.S.

V

+Vo

-Vo

_~

~~

DC VoltageSource

Signal Rtn

Enable

+s

-s

Gnd

AC

AC

WA

V

P.S. ++Vo

--Vo

V_

V_~

~~Shunt Res.

Signal Rtn

-s Shunt Res.

Inhibit

+12Vaux

+s

SW

Electronicload

Electronicload

V_

V_

+

-

AC

AC

Gnd

Osc

illo

scop

eO

scill

oscope

Osci

llosco

pe

0~5

Vprog.

-S

AC PowerSupply

AC PowerSupply

SW.

SW.

0~5V

Vprog.

-S

TDK-Lambda T-2

Page 5: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

(7) Dynamic line response characteristics

Digital power meter

230VAC

(8) Dynamic load response characteristics

Digital power meter

SW.

230VAC

Controlled temp.chamber

WA

V~

~~

Shunt Res.

P.S.

V

+Vo

-Vo

_

V_

Electronicload

+

-

-s

Enable

Signal Rtn

AC

AC

+s

0

Gnd

WA

V

P.S.

V

++Vo

--Vo

V_

_~

~~Shunt Res.

Signal Rtn

-sShunt Res.

Enable

+12Vaux

+s

Electronicload

Electronicload

V_

V_

AC

AC

+

-0

Gnd

0~5V

Vprog.

-S

0~5V

Vprog.

-S

Osc

illo

scop

eO

scill

osc

op

eO

sci

llosco

pe

AC PowerSupply

AC PowerSupply

SW.

TDK-Lambda T-3

Page 6: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

Dynamic load response characteristics

Output current waveform Output current waveformIout 0% <---> 100% Iout 50% <---> 100%

tr = 100µs tr = 100µstf = 100µs tf = 100µs

(9) Inrush current characteristics

230VAC

tr tf

0%5%

95%100%

trtf

50%55%

95%100%

0%

P.S.

V

++Vo

--Vo

V_

_

Shunt Res.InrushCurrentTester

-s

Signal Rtn

Shunt Res.

Enable

+12Vaux

Electronicload

+s

AC

AC

V_

Electronicload

+

-

V_

0

Gnd

0~5

Vprog.

-S

Osci

llosc

op

e

AC PowerSupply

TDK-Lambda T-4

Page 7: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

(10) Leakage current characteristics

230VAC

(11) Output ripple & noise waveform

(a) Normal mode

Controlled temp.chamber

230VAC

V__

P.S. +

+Vo

--Vo

Shunt Res.

GndLeakage current meter(As defined by IEC 950)

S.D

V~

-s

Signal Rtn

Shunt Res.

Enable

+12Vaux

Electronicload

Electronicload

V_

V_

+s

V_

+

-

AC

AC

P.S. ++Vo

-

FG

SW.

OscilloscopeBW:20MHz

50 Ohm

4700pF

V~

Signal Rtn

Enable

+12Vaux

-s

Electronicload

Electronicload

+

-50 Ohm

4700pF

probe,1.5m 50 Ohm

+s

AC

AC

OscilloscopeBW:20MHz

0

Vprog.

0~5

Vprog.

-S

4X

270

uF

470

uF

-Vo

AC PowerSupply

-S 0~5V

TDK-Lambda T-5

Page 8: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

1.2 List of equipment used

LEAKAGE CURRENT TESTER16

ELECTRONIC LOAD

ELECTRONIC LOAD

ELECTRONIC LOAD15

8 DIGITAL MULTI METER (DMM)

9 DIGITAL OSCILLOSCOPE

10

11

12

13

14

DIGITAL POWER METER

ELECTRONIC LOAD

ELECTRONIC LOAD

6 CURRENT PROBE

7 CURRENT TRANSDUCER

YOKOGAWA

DANFYSIK

4 CONTROLLED TEMP. CHAMBER

5 CONTROLLED TEMP. CHAMBER THERMOTRON

EQUIPMENT USED

3 CONTROLLED TEMP. CHAMBER

AC POWER SUPPLY1

2 AC POWER SUPPLY

MANUFACTURER

CHROMA

CHROMA

THERMOTRON

THERMOTRON

H & H

H & H

KIKUSUI

AGILENT

YOKOGAWA

YOKOGAWA

CHROMA

CHROMA

CHROMA

MODEL NO.

6463

6590

SE-600-5-5

SE-600-6-6

SM-16-3800

701933

ULTRASTAB 867

3401A

DL1740E / DL1740EL

ZS7006

TOS3200

WT110

63203

63204

63206

ZS7060

TDK-Lambda T-6

Page 9: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2. Characteristics

2.1 Steady state data

(1) Regulation - line and load, Temperature drift, Start-up voltage and Drop out voltage

12V 1. Regulation - line and load Conditions IAUX. : 0.5 ATa : 25 °C

Iout \ Vin 85VAC 115VAC 132VAC0% 12.003V 12.003V 12.003V 0mV 0.00%

50% 11.999V 11.999V 11.999V 0mV 0.00%100% 11.993V 11.993V 11.993V 0mV 0.00%

10mV 10mV 10mV0.08% 0.08% 0.08%

Iout \ Vin 170VAC 230VAC 265VAC0% 12.005V 12.005V 12.005V 0mV 0.00%

50% 11.994V 11.994V 11.994V 0mV 0.00%100% 11.975V 11.975V 11.975V 0mV 0.00%

30mV 30mV 30mV0.25% 0.25% 0.25%

2. Temperature drift Conditions Vin : 230 VACIout : 100 %IAUX. : 0.5 A

Ta -10°C 25°C 50°CVout 12.001V 11.990V 11.972V 0.029V 0.24% 28ppm

Load

Regulation

Line Regulation

Load

Regulation

Line Regulation

* Note: Load at 85VAC is derated according to specification

Temp. Stability

TDK-Lambda T-7

Page 10: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

(1) Regulation - line and load, Temperature drift, Start-up voltage and Drop out voltage

24V 1. Regulation - line and load Conditions IAUX. : 0.5 ATa : 25 °C

Iout \ Vin 85VAC 115VAC 132VAC0% 24.001V 24.001V 24.001V 0mV 0.00%

50% 24.001V 23.999V 23.999V 2mV 0.01%100% 23.997V 23.994V 23.993V 4mV 0.02%

4mV 7mV 8mV0.02% 0.03% 0.03%

Iout \ Vin 170VAC 230VAC 265VAC0% 24.000V 24.000V 24.000V 0mV 0.00%

50% 23.992V 23.992V 23.992V 0mV 0.00%100% 23.981V 23.978V 23.978V 3mV 0.01%

19mV 22mV 22mV0.08% 0.09% 0.09%

2. Temperature drift Conditions Vin : 230 VACIout : 100 %IAUX. : 0.5 A

Ta -10°C 25°C 50°CVout 24.029V 24.029V 24.025V 0.004V 0.02% 3ppm

Line Regulation

Load

Regulation

Load

Regulation

Line Regulation

* Note: Load at 85VAC is derated according to specification

Temp. Stability

TDK-Lambda T-8

Page 11: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

(1) Regulation - line and load, Temperature drift, Start-up voltage and Drop out voltage

48V 1. Regulation - line and load Conditions IAUX. : 0.5 ATa : 25 °C

Iout \ Vin 85VAC 115VAC 132VAC0% 48.004V 48.004V 48.004V 0mV 0.00%

50% 48.005V 48.005V 48.005V 0mV 0.00%100% 47.995V 47.995V 47.996V 1mV 0.00%

10mV 10mV 9mV0.02% 0.02% 0.02%

Iout \ Vin 170VAC 230VAC 265VAC0% 48.013V 48.012V 48.012V 1mV 0.00%

50% 48.006V 48.006V 48.007V 1mV 0.00%100% 47.992V 47.993V 47.993V 1mV 0.00%

21mV 19mV 19mV0.04% 0.04% 0.04%

2. Temperature drift Conditions Vin : 230 VACIout : 100 %IAUX. : 0.5 A

Ta -10°C 25°C 50°CVout 48.007V 47.936V 47.826V 0.181V 0.38% 44ppm

Line Regulation

Load

Regulation

Line Regulation

Load

Regulation

* Note: Load at 85VAC is derated according to specification

Temp. Stability

TDK-Lambda T-9

Page 12: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.1 Steady state data

(2) Output voltage and Ripple noise voltage vs. Input voltage

Conditions Iout : 100 %Ta : -10 °C

: 25 °C12V : 50 °C

Ta \ Vin 85VAC 115VAC 230VAC 265VAC204mV 212mV 304mV 304mV12.0V 12.0V 12.0V 12.0V72mV 81mV 104mV 102mV12.0V 12.0V 12.0V 12.0V56mV 64mV 85mV 83mV12.0V 12.0V 12.0V 12.0V

24V

Ta \ Vin 85VAC 115VAC 230VAC 265VAC128mV 120mV 144mV 207mV24.0V 24.0V 24.0V 24.0V72mV 75mV 91mV 93mV24.0V 24.0V 24.0V 24.0V80mV 86mV 107mV 108mV24.0V 24.0V 24.0V 24.0V

48V

Ta \ Vin 85VAC 115VAC 230VAC 265VAC420mV 450mV 530mV 530mV48.0V 48.0V 48.0V 48.0V50mV 50mV 70mV 70mV48.0V 48.0V 48.0V 48.0V45mV 50mV 80mV 75mV48.0V 48.0V 48.0V 48.0V

60°C

60°C

-20°C

25°C

-20°C

25°C

60°C

-20°C

25°C

0

150

300

450

600

750

900

0.0

10.0

20.0

30.0

40.0

50.0

60.0

50 100 150 200 250 Rip

ple

no

ise

volt

age

(mV

)

Ou

tpu

t vol

tage

(V

)

Input voltage (VAC)

Output voltage

Ripple noise voltage

0

150

300

450

600

750

900

0.0

5.0

10.0

15.0

20.0

25.0

30.0

50 100 150 200 250 Rip

ple

noi

se v

olta

ge (

mV

)

Ou

tpu

t vol

tage

(V

)

Input voltage (VAC)

Output voltage

Ripple noise voltage

0

150

300

450

600

750

900

0.0

3.0

6.0

9.0

12.0

15.0

18.0

50 100 150 200 250 Rip

ple

noi

se v

olta

ge (

mV

)

Ou

tpu

t vol

tage

(V

)

Input voltage (VAC)

Output voltage

Ripple noise voltage

TDK-Lambda T-10

Page 13: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.1 Steady state data

(3) Efficiency and Input current vs. Output currentConditions Vin : 85 VAC

: 115 VAC : 230 VAC : 265 VAC

12V Ta : 25 °C

Vin \ Iout 20 % 50 % 75 % 100 %83.3% 88.2% 89.1% 88.6%3.5A 8.1A 11.9A 16.0A

86.0% 90.2% 90.6% 90.3%3.1A 7.3A 10.9A 14.5A

89.7% 92.3% 92.4% 91.7%2.6A 5.8A 8.6A 11.5A

89.9% 92.5% 92.6% 92.2%2.4A 5.1A 7.5A 10.0A

24V

Vin \ Iout 20 % 50 % 75 % 100 %81.1% 87.7% 89.0% 88.8%3.5A 8.0A 11.9A 15.9A

84.2% 90.1% 90.7% 90.3%3.1A 7.2A 10.7A 14.3A

88.5% 92.1% 92.2% 91.4%2.5A 5.6A 8.3A 11.1A

88.4% 92.3% 92.5% 92.0%2.3A 4.9A 7.2A 9.6A

48V

Vin \ Iout 20 % 50 % 75 % 100 %85.3% 89.5% 90.4% 89.9%3.4A 7.7A 11.8A 15.8A

87.6% 91.3% 91.8% 91.5%3.1A 7.2A 10.7A 14.3A

91.3% 93.4% 93.4% 93.0%2.6A 5.8A 8.5A 11.4A

91.2% 93.6% 93.7% 93.3%2.3A 5.1A 7.5A 9.9A

265VAC

85VAC

115VAC

230VAC

85VAC

115VAC

230VAC

85VAC

115VAC

230VAC

265VAC

265VAC

70

75

80

85

90

95

0.0

6.0

12.0

18.0

24.0

30.0

0 20 40 60 80 100 120

Eff

icie

ncy

(%

)

Inp

ut

curr

ent (

A)

Output current (%)

Efficiency

Input current

70

75

80

85

90

95

0.0

6.0

12.0

18.0

24.0

30.0

0 20 40 60 80 100 120

Eff

icie

ncy

(%

)

Inpu

t cu

rren

t (A

)

Output current (%)

Efficiency

Input current

70

75

80

85

90

95

0.0

6.0

12.0

18.0

24.0

30.0

0 20 40 60 80 100 120

Eff

icie

ncy

(%

)

Inp

ut c

urre

nt (

A)

Output current (%)

Efficiency

Input current

TDK-Lambda T-11

Page 14: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.2 Warm up voltage drift characteristics

Conditions Vin : 230 VACIout : 100 %Ta : 25 °C

12V

Time (hrs) Drift (%)0 0.14

0.5 0.001 -0.012 0.003 0.004 0.005 0.006 0.007 0.008 0.00

24V

Time (hrs) Drift (%)0 -0.04

0.5 0.001 0.012 0.013 0.004 0.005 0.006 0.007 0.008 0.00

48V

Time (hrs) Drift (%)0 0.1500

0.5 0.00001 0.00002 0.00503 0.00804 0.00905 0.01006 0.00907 0.00908 0.0100

-0.4

-0.2

0.0

0.2

0.4

0 2 4 6 8

Ou

tpu

t v

olt

age

dri

ft (

%)

Time (hrs)

-0.4

-0.2

0.0

0.2

0.4

0 2 4 6 8Ou

tpu

t vo

ltag

e d

rift

(%

)

Time (hrs)

-0.4

-0.2

0.0

0.2

0.4

0 2 4 6 8Ou

tpu

t vo

ltag

e d

rift

(%

)

Time (hrs)

TDK-Lambda T-12

Page 15: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.3 Over voltage protection (OVP) characteristics

Conditions Vin : 230 VACIout : 0 %Ta : 25 °C

12V

24V

48V

5V/div 0.5s/div

10V/div 0.5s/div

20V/div 2s/div

VoutOVP point

0V

VoutOVP point

0V

VoutOVP point

0V

TDK-Lambda T-13

Page 16: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.4 Over current protection (OCP) characteristics

Conditions Vin : 85 VAC : 115 VAC : 230 VAC

Ta : 25 °C12V

12.0V 0.0A 0.0% 0.0A 0.0% 0.0A 0.0%

12.0V 112.3A 56.2% 163.1A 81.6% 214.8A 107.4%

11.0V 121.6A 60.8% 174.5A 87.3% 215.5A 107.8%

10.0V 134.3A 67.2% 198.1A 99.1% 216.1A 108.1%

9.0V 148.3A 74.2% 218.1A 109.1% 216.6A 108.3%

8.0V 166.7A 83.4% 217.7A 108.9% 217.3A 108.7%

5.0V 219.5A 109.8% 220.1A 110.1% 219.5A 109.8%

4.0V 220.3A 110.2% 220.4A 110.2% 220.1A 110.1%

3.0V 222.6A 111.3% 223.0A 111.5% 221.9A 111.0%

0.2V 211.2A 105.6% 211.3A 105.7% 210.7A 105.4%

24V

24.0V 0.0A 0.0% 0.0A 0.0% 0.0A 0.0%

24.0V 52.8A 55.0% 76.9A 80.1% 102.5A 106.8%

23.0V 55.3A 57.6% 80.7A 84.1% 102.5A 106.8%

22.0V 58.0A 60.4% 84.2A 87.7% 102.6A 106.9%

16.0V 86.8A 90.4% 102.7A 107.0% 102.9A 107.2%

12.0V 103.0A 107.3% 102.9A 107.2% 103.0A 107.3%

8.0V 104.3A 108.6% 104.2A 108.5% 104.1A 108.4%

5.0V 104.0A 108.3% 103.8A 108.1% 103.7A 108.0%

4.0V 103.0A 107.3% 103.1A 107.4% 103.1A 107.4%

0.0V 97.0A 101.0% 97.2A 101.3% 97.7A 101.8%

48V

48.0V 0.0A 0.0% 0.0A 0.0% 0.0A 0.0%

48.0V 25.0A 50.0% 31.5A 63.0% 52.0A 104.0%

47.0V 29.1A 58.2% 41.8A 83.6% 55.0A 110.0%

45.0V 30.5A 61.0% 43.6A 87.2% 55.1A 110.2%

43.0V 31.8A 63.6% 45.1A 90.2% 55.1A 110.2%

40.0V 35.9A 71.8% 48.9A 97.8% 55.2A 110.4%

38.0V 38.1A 76.2% 51.1A 102.2% 55.2A 110.4%

35.0V 41.4A 82.8% 55.3A 110.6% 55.4A 110.8%

30.0V 48.0A 96.0% 55.4A 110.8% 55.5A 111.0%

25.0V 55.4A 110.8% 55.5A 111.0% 55.4A 110.8%

10.0V 53.3A 106.6% 53.2A 106.4% 53.3A 106.6%

5.0V 49.0A 98.0% 49.2A 98.4% 49.1A 98.2%

0.0V 56.0A 112.0% 56.1A 112.2% 56.0A 112.0%

85VAC 115VAC 230VAC

85VAC 115VAC 230VAC

85VAC 115VAC 230VAC

0.0

8.0

16.0

24.0

32.0

40.0

48.0

15 25 35 45 55

Ou

tpu

t v

olt

ag

e (V

)

Output current (%)

0.0

4.0

8.0

12.0

16.0

20.0

24.0

30 50 70 90 110

Ou

tpu

t vo

ltag

e (V

)

Output current (%)

0.0

2.0

4.0

6.0

8.0

10.0

12.0

60 100 140 180 220

Ou

tpu

t v

olta

ge

(V)

Output current (A)

TDK-Lambda T-14

Page 17: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.5 Output rise characteristics

Conditions Vin : 85 VAC (A) : 115 VAC (B) : 230 VAC (C) : 265 VAC (D)

12V Iout : 0 %Ta : 25 °C

24V

48V

Vout: 5V/div 200ms/div

Vout: 10V/div 200ms/div

Vout: 20V/div 200ms/div

Vout

0V

Vin

ABDC

Vout

0V

Vin

ABDC

Vout

0V

Vin

ADBC

TDK-Lambda T-15

Page 18: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.5 Output rise characteristics

Conditions Vin : 85 VAC (A) : 115 VAC (B) : 230 VAC (C) : 265 VAC (D)

12V Iout : 100 %Ta : 25 °C

24V

48V

Vout: 5V/div 200ms/div

Vout: 10V/div 200ms/div

Vout: 20V/div 200ms/div

Vout

0V

Vin

ADCB

Vout

0V

Vin

ADCB

Vout

0V

Vin

ACDB

TDK-Lambda T-16

Page 19: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.6 Output fall characteristics

Conditions Vin : 85 VAC (A) : 115 VAC (B) : 230 VAC (C) : 265 VAC (D)

12V Iout : 0 %Ta : 25 °C

24V

48V

Vout: 5V/div 2s/div

Vout: 10V/div 2s/div

Vout: 20V/div 2s/div

Vout

0V

Vin

ABCD

Vout

0V

Vin

Vout

0V

Vin

ABCD

ABCD

TDK-Lambda T-17

Page 20: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.6 Output fall characteristics

Conditions Vin : 85 VAC (A) : 115 VAC (B) : 230 VAC (C) : 265 VAC (D)

12V Iout : 100 %Ta : 25 °C

24V

48V

Vout: 5V/div 10ms/div

Vout: 10V/div 10ms/div

Vout: 20V/div 10ms/div

Vout

0V

Vin

Vout

0V

Vin

A BCD

A

Vout

0V

Vin

BCD

A BDC

TDK-Lambda T-18

Page 21: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.7 Output rise characteristics with ON/OFF CONTROL

Conditions Vin : 115 VACIout : 100 %Ta : 25 °C

12V

24V

48V

100ms/divVout: 20V/div

100ms/divVout: 5V/div

100ms/divVout: 10V/div

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

TDK-Lambda T-19

Page 22: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.7 Output rise characteristics with ON/OFF CONTROL

Conditions Vin : 230 VACIout : 100 %Ta : 25 °C

12V

24V

48V

Vout: 5V/div 100ms/div

Vout: 10V/div 100ms/div

Vout: 20V/div 100ms/div

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

TDK-Lambda T-20

Page 23: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.8 Output fall characteristics with ON/OFF CONTROL

Conditions Vin : 115 VACIout : 100 %Ta : 25 °C

12V

24V

48V

Vout: 20V/div 100ms/div

Vout: 5V/div 100ms/div

Vout: 10V/div 100ms/div

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

TDK-Lambda T-21

Page 24: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.8 Output fall characteristics with ON/OFF CONTROL

Conditions Vin : 230 VACIout : 100 %Ta : 25 °C

12V

24V

48V

Vout: 20V/div 100ms/div

Vout: 5V/div 100ms/div

Vout: 10V/div 100ms/div

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

Vout

0V

ON/OFF CONTROL(ENABLE)

DC_OK

TDK-Lambda T-22

Page 25: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.9 Hold up time characteristics

Conditions Vin : 115 VAC : 230 VAC

Ta : 25 °C

12V

Iout 115VAC 230VAC0 % 34.1ms 45.8ms

20 % 31.9ms 42.4ms40 % 31.0ms 22.4ms60 % 26.2ms 16.4ms80 % 18.5ms 12.0ms

100 % 13.5ms 9.1ms

24V

Iout 115VAC 230VAC0 % 34.0ms 45.0ms

20 % 32.6ms 41.9ms40 % 32.1ms 28.4ms60 % 30.1ms 20.1ms80 % 22.8ms 12.6ms

100 % 17.5ms 9.3ms

48V

Iout 115VAC 230VAC0 % 40.0ms 56.5ms

20 % 35.6ms 46.0ms40 % 35.3ms 29.2ms60 % 31.0ms 18.7ms80 % 23.0ms 13.5ms

100 % 16.0ms 10.5ms

1

10

100

1000

0 20 40 60 80 100

Ho

ld u

p t

ime

(ms)

Output current (%)

1

10

100

1000

0 20 40 60 80 100

Ho

ld u

p t

ime

(ms)

Output current (%)

1

10

100

1000

0 20 40 60 80 100

Ho

ld u

p t

ime

(ms)

Output current (%)

TDK-Lambda T-23

Page 26: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.10 Dynamic line response characteristics

Conditions Vin : 85 VAC ↔ 132 VAC (A): 170 VAC ↔ 265 VAC (B)

Iout : 100 %Ta : 25 °C

12V

24V

48V

Vout (B): 200mV/div

500ms/div

500ms/div

500ms/div

Vout (A): 200mV/div Vin: 500V/div

Vout (A): 200mV/div Vin: 500V/div

Vout (A): 200mV/div Vin: 500V/div

Vout (B): 200mV/div

Vout (B): 200mV/div

Vout (A)

Vin

Vout (B)

Vout (A)

Vin

Vout (B)

Vout (A)

Vin

Vout (B)

TDK-Lambda T-24

Page 27: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.11 Dynamic load response characteristics

Conditions Vin : 230 VACTa : 25 °C

12V

f=100Hz

0.550V -0.620V 1.000V -1.300V

f=500Hz

0.550V -0.620V 1.050V -1.250V

Iout: 50% ↔ 100% Iout: 10% ↔ 100%

Vout: 1V/div 2ms/div+4.58% -5.17%

Vout: 2V/div+8.33% -10.83%

2ms/div

500μs/div+8.75% -10.42%

Iout: 50% ↔ 100% Iout: 10% ↔ 100%

Vout: 1V/div 500μs/div+4.58% -5.17%

Vout: 2V/div

Vout

Iout

Vout

Iout

TDK-Lambda T-25

Page 28: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.11 Dynamic load response characteristics

Conditions Vin : 230 VACTa : 25 °C

24V

f=100Hz

0.350V -0.450V 0.650V -0.950V

f=500Hz

0.350V -0.430V 0.350V -0.600V

+1.46% -1.88% +2.71% -3.96%

+1.46% -1.79% +1.46% -2.50%

Iout: 50% ↔ 100% Iout: 0% ↔ 100%

Vout: 500mV/div 500μs/div Vout: 0.5V/div 500μs/div

Iout: 0% ↔ 100%

Vout: 500mV/div 2ms/div Vout: 0.5V/div 2ms/div

Iout: 50% ↔ 100%

Vout

Iout

Vout

Iout

TDK-Lambda T-26

Page 29: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.11 Dynamic load response characteristics

Conditions Vin : 230 VACTa : 25 °C

48V

f=100Hz

0.660V -0.700V 1.260V -3.110V

f=500Hz

0.590V -0.630V 1.130V -2.040V

+1.23% -1.31% +2.35% -4.25%

+2.63% -6.48%

Iout: 50% ↔ 100% Iout: 0% ↔ 100%

Vout: 2V/div 500μs/div

+1.38% -1.46%

Vout: 1V/div 500μs/div

Iout: 50% ↔ 100% Iout: 0% ↔ 100%

Vout: 1V/div 2ms/div Vout: 2V/div 2ms/div

Vout

Iout

Vout

Iout

TDK-Lambda T-27

Page 30: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.12 Response to brown out characteristics

Conditions Vin : 115 VACIout : 100 %Ta : 25 °C

12V

A = 14msB = 24msC = 27ms

24V

A = 14msB = 24msC = 26ms

48V

A = 16msB = 18msC = 32ms

Vout: 5V/div 20ms/div

Vout: 10V/div 20ms/div

Vout: 20V/div 20ms/div

Vout

Vin

0V

CBA

Vout

Vin

0V

CBA

Vout

Vin

0V

CB A

TDK-Lambda T-28

Page 31: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.12 Response to brown out characteristics

Conditions Vin : 230 VACIout : 100 %Ta : 25 °C

12V

A = 6msB = 15msC = 29ms

24V

A = 9msB = 15msC = 26ms

48V

A = 10msB = 11msC = 28ms

Vout: 5V/div 20ms/div

Vout: 10V/div 20ms/div

Vout: 20V/div 20ms/div

Vout

Vin

0V

Vout

Vin

0V

CBA

CBA

CB A

Vout

Vin

0V

TDK-Lambda T-29

Page 32: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.14 Inrush current waveform

Conditions Vin : 115 VACIout : 100 %Ta : 25 °C

12V

Switch on phase angleof input AC voltage

Φ = 0°

Switch on phase angleof input AC voltage

Φ = 90°

Iin: 50A/div 100ms/div

Iin: 50A/div 100ms/div

Iin

Vin

Iin

Vin

TDK-Lambda T-30

Page 33: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.14 Inrush current waveform

Conditions Vin : 230 VACIout : 100 %Ta : 25 °C

12V

of input AC voltageΦ = 90°

Iin: 50A/div 100ms/div

Switch on phase angleof input AC voltage

Φ = 0°

Iin: 50A/div 100ms/div

Switch on phase angle

Iin

Vin

Iin

Vin

TDK-Lambda T-31

Page 34: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.15 Input current waveform

Conditions Iout : 100 %Ta : 25 °C

12V

Iin: 10A/div 5ms/div

Vin = 115VAC

Vin = 230VAC

Iin: 10A/div 5ms/div

Iin

Vin

Iin

Vin

TDK-Lambda T-32

Page 35: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.16 Leakage current characteristics

Conditions Iout : 0 %: 100 %

Ta : 25 °Cf : 60 Hz

12V

100VAC 115VAC 230VAC 265VAC0 % 0.540mA 0.620mA 1.250mA 1.470mA

100 % 0.540mA 0.651mA 1.300mA 1.550mA

48V

100VAC 115VAC 230VAC 265VAC0 % 0.539mA 0.622mA 1.150mA 1.320mA

100 % 0.568mA 0.622mA 1.210mA 1.410mA

0.0

0.6

1.2

1.8

80 120 160 200 240 280

Lea

ka

ge

curr

ent

(mA

)

Input voltage (VAC)

0.0

0.6

1.2

1.8

80 120 160 200 240 280

Lea

kag

e cu

rren

t (m

A)

Input voltage (VAC)

TDK-Lambda T-33

Page 36: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.17 Output ripple and noise waveform

Conditions Vin : 115 VACIout : 100 %Ta : 25 °C

12V

24V

48V

Vout: 10mV/div 5μs/div

NORMAL MODE

Vout: 10mV/div 5μs/div

Vout: 10mV/div 5μs/div

TDK-Lambda T-34

Page 37: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.17 Output ripple and noise waveform

Conditions Vin : 230 VACIout : 100 %Ta : 25 °C

12V

24V

48V

Vout: 10mV/div 5μs/div

NORMAL MODE

Vout: 10mV/div 5μs/div

Vout: 10mV/div 5μs/div

TDK-Lambda T-35

Page 38: Evaluation Data - RFE2500 Series - product.tdk.com

RFE2500

2.18 Standby current

Condition Ta : 25 °C

24V

Iout = 0%

85VAC 115VAC 132VAC 170VAC 230VAC 265VAC0.620A 0.628A 0.616A 0.545A 0.483A 0.498A

Remote control OFF

85VAC 115VAC 132VAC 170VAC 230VAC 265VAC0.455A 0.349A 0.338A 0.330A 0.357A 0.383A

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

80 100 120 140 160 180 200 220 240 260

Inp

ut

curr

ent

(A)

Input voltage (VAC)

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

80 100 120 140 160 180 200 220 240 260

Inp

ut

curr

ent

(A)

Input voltage (VAC)

TDK-Lambda T-36