40

ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

  • Upload
    hadat

  • View
    266

  • Download
    2

Embed Size (px)

Citation preview

Page 1: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk
Page 2: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk
Page 3: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

P

Preface

This document briefly explains the operations that need to be performed by the user in order toconnect an ETERNUS2000 model 100 or 200, an ETERNUS4000 model 300, 400, 500, or 600,or an ETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system to aserver running Solaris OS, HP-UX, AIX, Windows®, Linux, VMware ESX, or PAN Manager via aFibre Channel interface.

This document should be used in conjunction with any other applicable user manuals, such asthose for the ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, orETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system server,OS used, Fibre Channel cards or Converged Network Adapter cards, drivers, etc.This document references the following documents:

• ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) Fibre Channel Switch Settings

• Converged Enhanced Ethernet Administrator’s Guide• Fabric OS Administrator’s Guide• ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris• ETERNUSmgr User Guide

Also, note that in this document the ETERNUS2000 models 100 and 200, ETERNUS4000models 300, 400, 500, and 600, and ETERNUS8000 models 700, 800, 900, 1100, 1200, 2100,and 2200 Disk storage systems are collectively referred to as ETERNUS Disk storage systems.

Ninth EditionOctober 2013

The Contents and Structure of this Manual

This document is composed of the following three chapters.

• Chapter 1 Workflow

This describes the workflow required to set up an ETERNUS Disk storage system.

• Chapter 2 ETERNUS2000 Connection Settings

This describes the settings required when connecting an ETERNUS2000.

• Chapter 3 Common Settings

This describes the settings required when connecting an ETERNUS4000 or ETERNUS8000.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

3 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 4: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Preface

P

Safe Use of this Product

■ Using this manual

This manual contains important information to ensure the safe use of this product. Be sure tothoroughly read and understand its contents before using the product. After reading, store thismanual in a safe place for future reference.FUJITSU has made every effort to ensure the safety of the users and other personnel, and toprevent property damage. When using this product, carefully follow the instructions described inthis manual.

Acknowledgments

• Oracle and Java are registered trademarks of Oracle and/or its affiliates.• VERITAS Volume Manager is a trademark of Symantec Corp. and its affiliated companies.• HP-UX is a trademark of Hewlett-Packard Company in the U.S. and other countries.• AIX is a trademark of IBM Corp. in the U.S. and other countries.• Microsoft, Windows, and Windows Server are either registered trademarks or trademarks of

Microsoft Corporation in the United States and/or other countries.• Linux is a registered trademark of Linus Torvalds.• Egenera, BladeFrame and PAN Manager are trademarks or registered trademarks of

Egenera, Inc. in the United States and/or other countries.• Red Hat is a registered trademark of Red Hat, Inc. in the U.S. and other countries.• SUSE is a registered trademark of Novell, Inc. in the United States and other countries.• VMware and VMware logos are either registered trademarks or trademarks of VMware, Inc. in

the U.S. and/or other countries.• Brocade and the Brocade logo are trademarks or registered trademarks of Brocade

Communications Systems, Inc., in the United States and/or other countries.• The company names, product names and service names mentioned in this document are

registered trademarks or trademarks of their respective companies.

Naming Conventions

■ Product names

• Oracle Solaris might be described as Solaris, Solaris Operating System, or Solaris OS.

• "HP-UX" represents the following products.- HP-UX 11iv3- HP-UX 11iv2

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

4 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 5: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Preface

P

• "AIX" represents the following products.- AIX 6.1- AIX 5.3- AIX 5.2

• "Windows Server® 2008 R2" represents the following products.- Microsoft® Windows® Web Server 2008 R2- Microsoft® Windows Server® 2008 R2 Standard- Microsoft® Windows Server® 2008 R2 Enterprise- Microsoft® Windows Server® 2008 R2 Datacenter- Microsoft® Windows Server® 2008 R2 for Itanium-based Systems- Microsoft® Windows® HPC Server 2008 R2

• "Windows Server® 2008" represents the following products.- Microsoft® Windows Server® 2008 Standard- Microsoft® Windows Server® 2008 Enterprise- Microsoft® Windows Server® 2008 Datacenter- Microsoft® Windows® HPC Server 2008

• "Windows Server® 2003" represents the following products.- Microsoft® Windows Server® 2003, Standard Edition- Microsoft® Windows Server® 2003, Enterprise Edition- Microsoft® Windows Server® 2003, Standard x64 Edition- Microsoft® Windows Server® 2003, Enterprise x64 Edition- Microsoft® Windows Server® 2003 R2, Standard Edition- Microsoft® Windows Server® 2003 R2, Enterprise Edition- Microsoft® Windows Server® 2003 R2, Standard x64 Edition- Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition- Microsoft® Windows Server® 2003, Enterprise Edition for Itanium-based Systems- Microsoft® Windows Server® 2003, Datacenter Edition for Itanium-based Systems- Microsoft® Windows® Storage Server 2003 R2, Standard Edition- Microsoft® Windows® Storage Server 2003 R2, Enterprise Edition- Microsoft® Windows® Storage Server 2003 R2, Standard x64 Edition- Microsoft® Windows® Storage Server 2003 R2, Enterprise x64 Edition

• "Windows® 2000" represents the following products.- Microsoft® Windows® 2000 Server operating system- Microsoft® Windows® 2000 Advanced Server operating system

• "Linux" represents the following products.- Red Hat Enterprise Linux 5 (for x86)- Red Hat Enterprise Linux 5 (for Intel Itanium)- Red Hat Enterprise Linux 5 (for Intel64)- Red Hat Enterprise Linux AS (v.4 for x86)- Red Hat Enterprise Linux AS (v.4 for Itanium)- Red Hat Enterprise Linux AS (v.4 for EM64T)- Red Hat Enterprise Linux ES (v.4 for x86)- Red Hat Enterprise Linux ES (v.4 for EM64T)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

5 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 6: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Preface

P

- Red Hat Enterprise Linux WS (v.4)- Red Hat Enterprise Linux AS (v.3 for x86)- Red Hat Enterprise Linux AS (v.3 for Itanium)- Red Hat Enterprise Linux AS (v.3 for EM64T)- Red Hat Enterprise Linux ES (v.3 for x86)- Red Hat Enterprise Linux ES (v.3 for EM64T)- Red Hat Enterprise Linux AS (v.2.1 for x86)- Red Hat Enterprise Linux ES (v.2.1 for x86)- SUSE Linux Enterprise Server 11- SUSE Linux Enterprise Server 11 Service Packx- SUSE Linux Enterprise Server 11 for x86- SUSE Linux Enterprise Server 11 for EM64T- SUSE Linux Enterprise Server 11 for Itanium Processor Family- SUSE Linux Enterprise Server 11 Service Packx for x86 - SUSE Linux Enterprise Server 11 Service Packx for EM64T - SUSE Linux Enterprise Server 11 Service Packx for Itanium Processor Family - SUSE Linux Enterprise Server 10- SUSE Linux Enterprise Server 10 Service Packx- SUSE Linux Enterprise Server 10 for x86- SUSE Linux Enterprise Server 10 for EM64T- SUSE Linux Enterprise Server 10 for Itanium Processor Family- SUSE Linux Enterprise Server 10 Service Packx for x86 - SUSE Linux Enterprise Server 10 Service Packx for EM64T - SUSE Linux Enterprise Server 10 Service Packx for Itanium Processor Family - SUSE Linux Enterprise Server 9- SUSE Linux Enterprise Server 9 Service Pack x- SUSE Linux Enterprise Server 9 for x86- SUSE Linux Enterprise Server 9 for EM64T- SUSE Linux Enterprise Server 9 for Itanium Processor Family- SUSE Linux Enterprise Server 9 for x86 Service Pack x- SUSE Linux Enterprise Server 9 for EM64T Service Pack x- SUSE Linux Enterprise Server 9 for Itanium Processor Family Service Pack x- SUSE Linux Enterprise Server 8- SUSE Linux Enterprise Server 8 Service Pack x- SUSE Linux Enterprise Server 8 for x86- SUSE Linux Enterprise Server 8 for EM64T- SUSE Linux Enterprise Server 8 for Itanium Processor Family- SUSE Linux Enterprise Server 8 for x86 Service Pack x- SUSE Linux Enterprise Server 8 for EM64T Service Pack x- SUSE Linux Enterprise Server 8 for Itanium Processor Family Service Pack x

• "VMware ESX" represents the following product.- VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)- VMware Infrastructure 3 (ESX 3.0.x, ESX 3.5, ESXi 3.5)- VMware ESX Server 2.5.x

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

6 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 7: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Preface

P

■ Other names

• "FC port" or "Channel Adapter" (CA) refers to the Fibre Channel interface module used in the ETERNUS Disk storage systems to connect to the server.

• "Fibre Channel card" refers to the Fibre Channel interface module normally used by the server. A "Host Bus Adapter" (HBA) or "Channel Adapter" (CA) may be used instead, depending on the server.

• "Converged Network Adapter card" refers to the FCoE interface module normally used in the server.

• Italics are used to show variables such as values and characters that appear in command parameters and output examples.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

7 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 8: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

8 Copyright 2013 FUJITSU LIMITED

P3AM-2822-09ENZ0

Contents

Chapter 1 Workflow .................................................................................111.1 For ETERNUS2000 Connection ...................................................................... 111.2 For ETERNUS4000 or ETERNUS8000 Connection ........................................ 13

Chapter 2 ETERNUS2000 Connection Settings ....................................162.1 Common Settings ............................................................................................. 16

2.1.1 Setting the To-server Connection Type (Setting the Port Parameters) ..................................... 162.1.2 Setting the Host Response Patterns ......................................................................................... 172.1.3 Registering the WWNs of the Accessing Fibre Channel Cards or

Converged Network Adapter Cards (Registering the WWNs) ................................................... 232.1.4 Creating and Allocating LUN Groups (Setting Host Affinity Groups) ......................................... 23

2.2 OS Specific Settings ........................................................................................ 242.2.1 Setting the Port Reset Groups ................................................................................................... 242.2.2 Setting the Sub System Parameters (for HP-UX only) .............................................................. 25

2.3 Checking the WWNs ........................................................................................ 25

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings...263.1 Common Settings ............................................................................................. 26

3.1.1 Setting the To-server Connection Type (Setting the CA Parameters) ....................................... 263.1.2 Setting the Server Accessible LUN Groups (Setting the Affinity Groups) ................................. 273.1.3 Setting the Host Responses ...................................................................................................... 283.1.4 Registering the WWNs of the Accessing Fibre Channel Cards or

Converged Network Adapter Cards (Registering the WWNs) ................................................... 353.1.5 Defining the Relationship between the Accessing Fibre Channel Cards or

Converged Network Adapter Cards and the LUN Groups (Allocating the Host-Affinity Groups) ......................................................................................... 36

3.2 OS Specific Settings ........................................................................................ 373.2.1 Setting the CA Reset Groups .................................................................................................... 373.2.2 Setting the Sub System Parameters (for HP-UX only) .............................................................. 38

3.3 Checking the WWNs ........................................................................................ 38

Page 9: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

P

Table of Contents

Table 2.1 FC port parameter settings (for FC-AL connection) .................................................................. 16Table 2.2 FC port parameter settings (for Fabric connection)................................................................... 17Table 2.3 Reservation Conflict Response for Test Unit Ready setting for Solaris OS .............................. 18Table 2.4 Sense Code Conversion setting for Solaris OS......................................................................... 18Table 2.5 Host Specific Mode setting for HP-UX....................................................................................... 18Table 2.6 Vendor Unique Sense Code setting for HP-UX......................................................................... 18Table 2.7 Sense Code Conversion Pattern setting for HP-UX .................................................................. 18Table 2.8 Host Specific Mode setting for AIX ............................................................................................ 19Table 2.9 Reservation Conflict Response for Test Unit Ready setting for AIX.......................................... 19Table 2.10 Reservation Conflict Response for Test Unit Ready setting for Windows® .............................. 19Table 2.11 Vendor Unique Sense Code setting for Windows®................................................................... 19Table 2.12 Sense Code Conversion setting for Windows®......................................................................... 20Table 2.13 Vendor Unique Sense Code setting for Windows®

(PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)............................. 20Table 2.14 Sense Code Conversion setting for Windows®

(PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)............................. 20Table 2.15 Sense Code Conversion setting for Linux ................................................................................. 21Table 2.16 Vendor Unique Sense Code setting for Linux

(PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)............................. 21Table 2.17 Sense Code Conversion setting for Linux

(PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)............................. 21Table 2.18 Inquiry Standard Data Version setting for VMware ESX ........................................................... 21Table 2.19 Sense Code Conversion setting for VMware ESX .................................................................... 22Table 2.20 Host Specific Mode setting for VMware ESX ........................................................................... 22Table 2.21 Inquiry Standard Data Version setting for Windows®-based VMware VCB Proxy server......... 22Table 2.22 Host Specific Mode setting for Windows®-based VMware VCB Proxy server.......................... 22Table 2.23 Sense Code Conversion setting for VMware ESX (PRIMEQUEST 1000 series connection) ... 22Table 2.24 Inquiry Standard Data Version setting for PAM Manager.......................................................... 23Table 2.25 Host Specific Mode setting for PAM Manager........................................................................... 23Table 2.26 Sense Code Conversion setting for PAN Manager ................................................................... 23Table 3.1 CA parameter settings (for FC-AL connection) ......................................................................... 26Table 3.2 CA parameter settings (for Fabric connection).......................................................................... 27Table 3.3 Reservation Conflict Response for Test Unit Ready setting for Solaris OS .............................. 28Table 3.4 Sense Code Conversion Pattern setting for Solaris OS ............................................................ 28Table 3.5 Host Specific Mode setting for HP-UX....................................................................................... 29Table 3.6 Sense Code Conversion Pattern setting for HP-UX .................................................................. 29Table 3.7 Host Specific Mode setting for AIX ............................................................................................ 29Table 3.8 Reservation Conflict Response for Test Unit Ready setting for AIX.......................................... 29Table 3.9 Reservation Conflict Response for Test Unit Ready setting for Windows® .............................. 30Table 3.10 Vendor Unique Sense Code setting for Windows®................................................................... 30Table 3.11 Sense Code Conversion Pattern setting for Windows®............................................................ 31Table 3.12 Vendor Unique Sense Code setting for Windows®

(PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)............................. 31Table 3.13 Sense Data Conversion Pattern setting for Windows®

(PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)............................. 31Table 3.14 Sense Code Conversion Pattern setting for Linux..................................................................... 32Table 3.15 Vendor Unique Sense Code setting for Linux

(PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)............................. 32

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

9 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 10: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Table of Contents

P

Table 3.16 Sense Data Conversion Pattern setting for Linux (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)............................. 32

Table 3.17 Inquiry Standard Data Version setting for VMware ESX ........................................................... 33Table 3.18 Sense Code Conversion Pattern setting for VMware ESX........................................................ 33Table 3.19 Host Specific Mode setting for VMware ESX ............................................................................ 33Table 3.20 Asymmetric/Symmetric Logical Unit Access for VMware ESX.................................................. 34Table 3.21 Inquiry Standard Data Version setting for Windows®-based VMware VCB Proxy server......... 34Table 3.22 Host Specific Mode setting for Windows®-based VMware VCB Proxy server.......................... 34Table 3.23 Sense Data Conversion Pattern setting for VMware ESX

(PRIMEQUEST 1000 series connection) .................................................................................. 34Table 3.24 Inquiry Standard Data Version setting for PAM Manager.......................................................... 35Table 3.25 Host Specific Mode setting for PAM Manager........................................................................... 35Table 3.26 Sense Code Conversion Pattern setting for PAN Manager....................................................... 35

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

10 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 11: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 1 Workflow

P

The ETERNUS Disk storage system setting procedures in this document are those referenced inthe "Setting Up the ETERNUS Disk Storage Systems" chapter of the "ETERNUS Disk storagesystems Server Connection Guide (Fibre Channel)" for each OS.

Decide which of the following workflows is to be used based on the ETERNUS Disk storage sys-tem model being connected.

1.1 For ETERNUS2000 Connection

Workflow

Set the Port ParametersSet the to-server connection type.

Refer

- "2.1.1 Setting the To-server Connection Type (Setting the Port Parameters)" (page 16)

Set the Host Response PatternsSet the host response patterns to match the connection configuration.

Refer

- "2.1.2 Setting the Host Response Patterns" (page 17)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

11 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 12: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 1 Workflow > 1.1 For ETERNUS2000 Connection

P

Register the WWNsRegister the WWNs of the accessing Fibre Channel cards or Converged Network Adapter cards.

Refer

- "2.1.3 Registering the WWNs of the Accessing Fibre Channel Cards or Converged Network Adapter Cards (Registering the WWNs)" (page 23)

Set the Host Affinity GroupsCreate LUN groups and define the LUN group associations.

Refer

- "2.1.4 Creating and Allocating LUN Groups (Setting Host Affinity Groups)" (page 23)

Set the Port Reset GroupsAssign the FC ports of the ETERNUS Disk storage system to the same port reset group, depending on the connection condition.

Refer

- "2.2.1 Setting the Port Reset Groups" (page 24)

Set the Sub-system Parameters (for HP-UX only)Set whether to enable [Disable load balance], a function to restrict sense responses that require the retry when the ETERNUS Disk storage system is in overload.

Refer

- "2.2.2 Setting the Sub System Parameters (for HP-UX only)" (page 25)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

12 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 13: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 1 Workflow > 1.2 For ETERNUS4000 or ETERNUS8000 Connection

P

After completing all the required procedures in this manual, follow the procedures in"ETERNUS Disk storage systems Server Connection Guide (Fibre Channel)" for eachOS.

1.2 For ETERNUS4000 or ETERNUS8000 Connection

Workflow

Check the ETERNUS Disk Storage System WWNsCheck the information required to connect to the server.

Refer

- "2.3 Checking the WWNs" (page 25)

Set the CA ParametersSet the to-server connection type.

Refer

- "3.1.1 Setting the To-server Connection Type (Setting the CA Parameters)" (page 26)

Set the Affinity GroupsSet the server accessible LUN groups.

Refer

- "3.1.2 Setting the Server Accessible LUN Groups (Setting the Affinity Groups)" (page 27)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

13 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 14: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 1 Workflow > 1.2 For ETERNUS4000 or ETERNUS8000 Connection

P

Set the Host ResponsesSet the host responses to match the connection configuration.

Refer

- "3.1.3 Setting the Host Responses" (page 28)

Register the WWNsRegister the WWNs of the accessing Fibre Channel cards or Converged Network Adapter cards.

Refer

- "3.1.4 Registering the WWNs of the Accessing Fibre Channel Cards or Converged Network Adapter Cards (Registering the WWNs)" (page 35)

Allocate Host-Affinity GroupsDefine the relationship between the accessing Fibre Channel cards or Converged Network Adapter cards and the LUN groups.

Refer

- "3.1.5 Defining the Relationship between the Accessing Fibre Channel Cards or Converged Network Adapter Cards and the LUN Groups (Allocating the Host-Affinity Groups)" (page 36)

Set the CA Reset GroupsAssign the CA ports of the ETERNUS Disk storage system to the same reset group, depending on the connection conditions.

Refer

- "3.2.1 Setting the CA Reset Groups" (page 37)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

14 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 15: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 1 Workflow > 1.2 For ETERNUS4000 or ETERNUS8000 Connection

P

After completing all the required procedures in this manual, follow the procedures in"ETERNUS Disk storage systems Server Connection Guide (Fibre Channel)" for eachOS.

Set the Sub-system Parameters (for HP-UX only)Set whether to enable [Disable Load Balance], a function that restricts retry-required sense responses when the ETERNUS Disk storage system is in overload.

Refer

- "3.2.2 Setting the Sub System Parameters (for HP-UX only)" (page 38)

Check the ETERNUS Disk Storage System WWNsDiscover the ETERNUS Disk storage system WWNs (required to connect to the server).

Refer

- "3.3 Checking the WWNs" (page 38)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

15 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 16: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings

P

2.1 Common Settings

This section explains the settings required for all server OSes, regardless of the connection con-figuration.For details of how to use ETERNUSmgr to perform these settings, refer to the "ETERNUSmgrUser Guide".

2.1.1 Setting the To-server Connection Type (Setting the Port Parameters)

For each connection configuration, perform the following FC port parameter settings only. Allother parameters should be left on their default values.

Table 2.1 FC port parameter settings (for FC-AL connection)

*1: Assign Loop-IDs that are unique within each Loop, in ascending order.*2: Set the appropriate value from the following table. Do not use the [Auto].

Parameter Solaris OSHP-UX, AIX,

Windows®, Linux, VMware ESX

PAN Manager

Connection Topology FC-AL Connection

Loop-ID (Manual) (*1)Values from 0x10

upwards(Except 0x7D)

0x00

FC Frame Size 2048Byte (Default value)

Transfer Rate See the table below (*2) 2Gbps

Host Affinity Mode Checkbox checked

Reset Scope I_T_L (Default value)

Reserve Cancel at Chip Reset Checkbox unchecked (Default value)

Fibre Channel card maximum speed

ETERNUS Disk storage system CA type

4Gbps CA

8Gbps 4Gbps

4Gbps 4Gbps

2Gbps 2Gbps

1Gbps 1Gbps

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

16 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 17: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.1 Common Settings

P

Table 2.2 FC port parameter settings (for Fabric connection)

*1: Set the appropriate value from the following table. Do not use the [Auto].

2.1.2 Setting the Host Response Patterns

The ETERNUS Disk storage system Host Response parameters must be set to match the way inwhich the server will process the ETERNUS Disk storage system request responses.These are different for each OS and this must be done before connecting the ETERNUS Diskstorage system to the server.Retain the default values for all parameters not described below.

Parameter Solaris OS, HP-UX, AIX, Windows®, Linux, VMware ESX, PAN Manager

Connection Topology Fabric Connection

FC Frame Size 2048Byte (Default value)

Transfer Rate See the table below (*1)

Host Affinity Mode Checkbox checked

Reset Scope I_T_L (Default value)

Reserve Cancel at Chip Reset Checkbox unchecked (Default value)

Fibre Channel switch or CEE/FCoE switch

maximum speed

ETERNUS Disk storage system CA type

4Gbps CA

8Gbps 4Gbps

4Gbps 4Gbps

2Gbps 2Gbps

1Gbps 1Gbps

When setting a Fabric connection, complete the preparatory work and setup the Fibre Channel switch or the CEE/FCoE switch beforehand. Forfurther details, refer to "ETERNUS Disk storage systems ServerConnection Guide (Fibre Channel) Fibre Channel Switch Settings" or"Fabric OS Administrator’s Guide" and "Converged Enhanced EthernetAdministrator’s Guide".

When setting the access path using the ETERNUS SF Storage Cruiser,Host Response No. will be set to default values.Set the Host Response No. after setting the access path using theETERNUS SF Storage Cruiser.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

17 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 18: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.1 Common Settings

P

2.1.2.1 Solaris OS

For Solaris OS, perform the settings detailed in Table 2.3 and Table 2.4.

Table 2.3 Reservation Conflict Response for Test Unit Ready setting for Solaris OS

Table 2.4 Sense Code Conversion setting for Solaris OS

2.1.2.2 HP-UX

For HP-UX, perform the settings detailed in Table 2.5 to Table 2.7.

Table 2.5 Host Specific Mode setting for HP-UX

Table 2.6 Vendor Unique Sense Code setting for HP-UX

Table 2.7 Sense Code Conversion Pattern setting for HP-UX

OSMPxIO (Sun Multipath Driver)

Used Not used

Solaris OS Conflict response Normal response (Default)

OS Sun or Brocade Fibre Channel card driver used

Sun or Brocade Fibre Channel card driver not used

Solaris OS Linux recommended No conversion (Default)

A Sun-brand Fibre Channel card driver may be used for Fujitsu FibreChannel cards. Check which drivers are usable in the "Notes" chapter andthe "Fibre Channel Cards that Require a Sun-brand Driver" section of the"ETERNUS Disk storage systems Server Connection Guide (FibreChannel) for Oracle Solaris".

OS [Host Specific Mode] setting

HP-UX HP-UX Mode

OS [Vendor Unique Sense Code] setting

HP-UX Do not report

OSIntegrity VM

Used Not used

HP-UX Linux recommended No conversion (Default)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

18 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 19: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.1 Common Settings

P

2.1.2.3 AIX

For AIX, perform the settings detailed in Table 2.8 and Table 2.9.

Table 2.8 Host Specific Mode setting for AIX

Table 2.9 Reservation Conflict Response for Test Unit Ready setting for AIX

2.1.2.4 Windows®

For Windows®, perform the settings detailed in Table 2.10 and Table 2.12.

Table 2.10 Reservation Conflict Response for Test Unit Ready setting for Windows®

For the host response Vendor Unique Sense Code, perform the settings detailed in Table 2.11.

Table 2.11 Vendor Unique Sense Code setting for Windows®

OS [Host Specific Mode] setting

AIX/VIOS AIX Mode

OS

ETERNUS MultipathDriver 2.0

used

ETERNUS MPIOfor IBM AIX2.0.xdriver used

VERITAS StorageFoundation

used

Single path configurationusing FJspio

PowerHA/HACMP used

PowerHA/HACMP not

used

AIX Conflict response

Normal response (Default)

Normal response (Default)

Conflict response

Normal response(Default)

VIOS Conflict response — — — —

Use of a PowerHA/HACMP cluster configuration only affects the"Reservation Conflict Response for Test Unit Ready" setting for single pathconfigurations using FJspio.

OS MSCS or WSFC configuration

VERITAS Cluster Server configuration

All other configurations

Windows Server® 2008Windows Server® 2008 R2

Normal response (Default) Normal response

(Default) Normal response (Default)Windows Server® 2003

Conflict responseWindows® 2000 —

OS

Connected server type

PRIMEQUEST 1000 series,

PRIMEQUEST 500/400 series

PRIMERGY, Industry Standard Server

GR/ETERNUS Multipath Drivermsdsm

Used Not used

Windows Server® 2008Windows Server® 2008 R2 Do not report Report

(Default)Report

(Default)

Do not report

Windows Server® 2003—

Windows® 2000 —

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

19 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 20: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.1 Common Settings

P

When a Windows® server and ETERNUS Disk storage system are multipath connected usingthe ETERNUS Multipath Driver or GR Multipath Driver, set the host response Sense CodeConversion to [No conversion].If the connection is performed without using the ETERNUS Multipath Driver or GR MultipathDriver, set the host response Sense Code Conversion to [Windows (When ETERNUS MPD notused) recommended].

Table 2.12 Sense Code Conversion setting for Windows®

When connecting a Windows®-based VMware VCB Proxy server to the ETERNUS Disk storagesystem, and the LUNs are shared between the VMware VCB Proxy server and VMware ESXserver, the setting detailed in "2.1.2.6 VMware ESX" (page 21) should be used.

When connecting a PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series and ETERNUSDisk storage system, perform the settings detailed in Table 2.13 and Table 2.14.

Table 2.13 Vendor Unique Sense Code setting for Windows® (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)

Table 2.14 Sense Code Conversion setting for Windows® (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)

OS

GR/ETERNUS Multipath Driver Standard Multipath Driver

for Windows Server® 2008

(msdsm)

VERITAS Storage

Foundation for Windows

Used Not used

Windows Server® 2008Windows Server® 2008 R2

No conversion (Default)

Windows (When

ETERNUS MPD not used) recommended

Windows (When

ETERNUS MPD not used) recommended

Windows (When

ETERNUS MPD not used) recommended

Windows Server® 2003—

Windows® 2000 —

Connected server type Setting

Vendor Unique Sense Code

PRIMEQUEST 1000 series PRIMEQUEST 500/400 series Do not report

Connected server typeSAN Boot configuration

Used Not used

PRIMEQUEST 1000 series PRIMEQUEST 500/400 series Linux recommended Follow the settings for each

environment

When the settings for each OS do not match the settings described above,perform the settings described above.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

20 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 21: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.1 Common Settings

P

2.1.2.5 Linux

For Linux, perform the settings detailed in Table 2.15.

Table 2.15 Sense Code Conversion setting for Linux

*1: VERITAS Volume Manager or device-mapper multipath should be used instead.

When connecting a PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series and ETERNUSDisk storage system, perform the settings detailed in Table 2.16 and Table 2.17.

Table 2.16 Vendor Unique Sense Code setting for Linux (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)

Table 2.17 Sense Code Conversion setting for Linux (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)

2.1.2.6 VMware ESX

For VMware ESX, perform the settings detailed in Table 2.18 to Table 2.20.The required setting value depends on what version of ESX is being used.

Table 2.18 Inquiry Standard Data Version setting for VMware ESX

OSETERNUS Multipath Driver

Used Not used (*1)

Red Hat Enterprise LinuxSUSE Linux Enterprise Server No conversion (Default) Linux recommended

Connected server type Setting

Vendor Unique Sense Code

PRIMEQUEST 1000 series PRIMEQUEST 500/400 series Do not report

Connected server typeSAN Boot configuration

Used Not used

PRIMEQUEST 1000 series PRIMEQUEST 500/400 series Linux recommended Follow the settings for each

environment

When the settings for each OS do not match the settings described above,perform the settings described above.

OS [Inquiry Standard Data Version] setting

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0) Version5 (Default)

VMware Infrastructure 3 (ESX 3.0.x, ESX 3.5, ESXi 3.5) Version4

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

21 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 22: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.1 Common Settings

P

Table 2.19 Sense Code Conversion setting for VMware ESX

Table 2.20 Host Specific Mode setting for VMware ESX

When connecting a Windows®-based VMware VCB Proxy server to the ETERNUS Disk storagesystem, and the LUNs are shared between the VMware VCB Proxy server and VMware ESXserver, the setting detailed in Table 2.21 and Table 2.22 should be used.For VMware VCB Proxy details, refer to the VMware web-site.

Table 2.21 Inquiry Standard Data Version setting for Windows®-based VMware VCB Proxy server

Table 2.22 Host Specific Mode setting for Windows®-based VMware VCB Proxy server

When connecting a PRIMEQUEST 1000 series and ETERNUS Disk storage system in a SANBoot configuration, perform the settings detailed in Table 2.23.

Table 2.23 Sense Code Conversion setting for VMware ESX (PRIMEQUEST 1000 series connection)

OS [Sense Code Conversion Pattern] setting

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)

VMware Infrastructure 3 (ESX 3.0.x, ESX 3.5, ESXi 3.5)

Linux recommended

OS [Host Specific Mode] setting

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0) VMware Mode

VMware Infrastructure 3 (ESX 3.0.x, ESX 3.5, ESXi 3.5) Normal Mode (Default)

OS [Inquiry Standard Data Version] setting

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)

VMware Infrastructure 3 (ESX 3.5, ESXi 3.5)

Windows Server® 2008 used as a VCB Proxy server Version5 (Default)

Windows Server® 2003 used as a VCB Proxy server Version4

OS [Host Specific Mode] setting

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)

VMware Infrastructure 3 (ESX 3.5, ESXi 3.5)

Windows Server® 2008 used as a VCB Proxy server VMware Mode

Windows Server® 2003 used as a VCB Proxy server Normal Mode (Default)

Connected server typeSAN Boot configuration

Used Not used

PRIMEQUEST 1000 series Linux recommended Follow the settings for each environment

When the settings for each OS do not match the settings described above,perform the settings described above.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

22 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 23: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.1 Common Settings

P

2.1.2.7 PAN Manager

For PAN Manager, perform the settings detailed in Table 2.24 to Table 2.26.

Table 2.24 Inquiry Standard Data Version setting for PAM Manager

Table 2.25 Host Specific Mode setting for PAM Manager

Contact Egenera, Inc. for guest OSes supported by PAN Manager.

Table 2.26 Sense Code Conversion setting for PAN Manager

2.1.3 Registering the WWNs of the Accessing Fibre Channel Cards or Converged Network Adapter Cards (Registering the WWNs)

Register the WWN of each Fibre Channel card or Converged Network Adapter card installed inthe server that will access the ETERNUS Disk storage system. At the same time, set the WWNsto the host responses registered in "2.1.2 Setting the Host Response Patterns" (page 17).

Registering WWNs and setting up Host Affinity Groups in "2.1.4 Creating and Allocating LUNGroups (Setting Host Affinity Groups)" (page 23), allows access restrictions (security) for theETERNUS Disk storage system to be set on a per-server basis.

2.1.4 Creating and Allocating LUN Groups (Setting Host Affinity Groups)

Create a LUN group (Host Affinity Group) for the server to access.Allocate the WWN of each server to a Host Affinity Group and specify which LUNs are to bemade accessible. This sets access restrictions to the ETERNUS Disk storage system from eachserver.

OS [Inquiry Standard Data Version] setting

PAN Manager Version5 (Default)

OS [Host Specific Mode] setting

Guest OS VMware ESX used Guest OS VMware ESX not used

PAN Manager VMware Mode Normal Mode (Default)

OS [Sense Code Conversion] setting

PAN Manager Linux recommended

When a server-side Fibre Channel card or Converged Network Adaptercard is replaced, the WWN of the replacement Fibre Channel card orConverged Network Adapter card must be re-registered to the ETERNUSDisk storage system.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

23 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 24: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.2 OS Specific Settings

P

2.2 OS Specific Settings

Some settings are not required for some server OSes and/or connection configurations.Check the various cases described below, and perform any required settings.

2.2.1 Setting the Port Reset Groups

If the system configuration matches any of the "System configuration that requires the port resetgroup setting" in the following table, every ETERNUS Disk storage system FC port that connectsto the given server's access paths must be assigned to the same port reset group.For system configurations other than the following, use the default settings.

*1: When multiple ESX servers share ETERNUS Disk storage system LUNs, any ETERNUS Disk storagesystem FC port that connects a shared LUN to an ESX server must be assigned to the same portreset group, whether multi-paths are used for the ESX servers or not.

• If the one-to-one relationship between the WWNs and Fibre Channelcards or Converged Network Adapter cards cannot be determined, theHost Affinity Group settings may not be allocated correctly.In this case, try various settings until the server is able to recognize theETERNUS Disk storage system logical disks.

• When the server OS is HP-UX, AIX, Windows®, Linux, VMware ESX, orPAN Manager, assign SCSI LUN numbers starting from LUN0 inascending order. The server cannot recognize the ETERNUS Diskstorage system LUNs unless they are assigned in this order.This restriction does not apply when the server is running a Solaris OS.

Server OS System configuration that requires the port reset group setting

Solaris 10 OSSolaris 9 OSSolaris 8 OS

• Sun Cluster configuration

AIX • Single path configuration using FJspio for a PowerHA or HACMP cluster

Windows Server® 2003Windows® 2000

• MSCS configuration

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0),VMware Infrastructure 3(ESX 3.0.x, ESX 3.5, ESXi 3.5)

• Multipath configurationor

• Multiple ESX servers share ETERNUS Disk storage system LUNs (*1)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

24 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 25: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 2 ETERNUS2000 Connection Settings > 2.3 Checking the WWNs

P

Example: When multiple ESX servers share ETERNUS Disk storage system LUNs, CM#0 Port#1and CM#1 Port#1 must be assigned to the same port reset group, even for single-pathconfigurations.

2.2.2 Setting the Sub System Parameters (for HP-UX only)

For HP-UX connection, select the [Disable load balance] checkbox of the "Set Sub SystemParameters" screen. This prevents sense responses that require access retries from beingissued when the ETERNUS Disk storage system is in an overload state.

2.3 Checking the WWNs

Use ETERNUSmgr to check the WWN of each ETERNUS Disk storage system FC port. Theyare required to connect the ETERNUS Disk storage system to the server.

Server#1 Server#2

Fibre Channel Switch#1 Fibre Channel Switch#2

HBA#1 HBA#1

Host Affinity Group

Port#1CM#0 CM#1

Port#1

For HP-UX server, improper logs may be recorded unless sense responseis restricted. Therefore, select the [Disable load balance] checkbox. (Senseresponse should be restricted.) Note that changing the [Disable loadbalance] setting does not affect on non-HP-UX servers.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

25 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 26: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings

P

3.1 Common Settings

This section explains the settings required for all server OSes, regardless of the connectionconfiguration. For details of how to use ETERNUSmgr to perform these settings, refer to the"ETERNUSmgr User Guide".

3.1.1 Setting the To-server Connection Type (Setting the CA Parameters)

For each connection configuration, set the indicated items only. All other parameters should beleft on their default values.

Table 3.1 CA parameter settings (for FC-AL connection)

*1: Assign Loop-IDs that are unique within each Loop, in ascending order.*2: Set the appropriate value from the following table. Do not use [8G/4G/2Gbps Auto] or [4G/2G/1Gbps

Auto].

Parameter Solaris OSHP-UX, AIX,

Windows®, Linux, VMware ESX

PAN Manager

Connection Topology FC-AL Connection

Loop-ID (Manual) (*1)Values from 0x10

upwards(Except 0x7D)

0x00

FC Frame Size 2048Byte (Default value)

Transfer Rate See the table below (*2) 2Gbps

Affinity Mode ON

Reset Scope I_T_L (Default value)

Reserve Cancel at Chip Reset OFF (Default value)

Fibre Channel cardmaximum speed

ETERNUS Disk storage system CA type

8Gbps CA 4Gbps CA

8Gbps 8Gbps 4Gbps

4Gbps 4Gbps 4Gbps

2Gbps 2Gbps 2Gbps

1Gbps — 1Gbps

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

26 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 27: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

Table 3.2 CA parameter settings (for Fabric connection)

*1: Set the appropriate value from the following table. Do not use [8G/4G/2Gbps Auto] or [4G/2G/1GbpsAuto].

3.1.2 Setting the Server Accessible LUN Groups (Setting the Affinity Groups)

Set which LUN groups (Affinity Groups) will be accessible by the server.

Parameter Solaris OS, HP-UX, AIX, Windows®, Linux, PAN Manager, VMware ESX

Connection Topology Fabric Connection

FC Frame Size 2048Byte (Default value)

Transfer Rate See the table below (*1)

Affinity Mode ON

Reset Scope I_T_L (Default value)

Reserve Cancel at Chip Reset OFF (Default value)

Fibre Channel switch or CEE/FCoE switch

maximum speed

ETERNUS Disk storage system CA type

8Gbps CA 4Gbps CA

8Gbps 8Gbps 4Gbps

4Gbps 4Gbps 4Gbps

2Gbps 2Gbps 2Gbps

1Gbps — 1Gbps

When setting a Fabric connection, complete the preparatory work and setup the Fibre Channel switch or the CEE/FCoE switch beforehand. Forfurther details, refer to "ETERNUS Disk storage systems ServerConnection Guide (Fibre Channel) Fibre Channel Switch Settings" or"Fabric OS Administrator’s Guide" and "Converged Enhanced EthernetAdministrator’s Guide".

When the server OS is HP-UX, AIX, Windows®, Linux, VMware ESX, orPAN Manager, assign Affinity Group values starting from LUN0 inascending order. The server cannot recognize the ETERNUS Disk storagesystem LUNs unless they are assigned in this order.This restriction does not apply when the server is running a Solaris OS.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

27 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 28: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

3.1.3 Setting the Host Responses

The ETERNUS Disk storage system Host Response parameters must be set to match the way inwhich the server will process the ETERNUS Disk storage system request responses.These are different for each OS and this must be done before connecting the ETERNUS Diskstorage system to the server.Retain the default values for all parameters not described below.

3.1.3.1 Solaris OS

For Solaris OS, perform the settings detailed in Table 3.3 and Table 3.4.

Table 3.3 Reservation Conflict Response for Test Unit Ready setting for Solaris OS

Table 3.4 Sense Code Conversion Pattern setting for Solaris OS

When setting the access path using the ETERNUS SF Storage Cruiser,Host Response No. will be set to default values.Set the Host Response No. after setting the access path using theETERNUS SF Storage Cruiser.

OSMPxIO (OS standard Multipath Driver)

Used Not used

Solaris OS Conflict Response Normal Response (Default)

OS

When MPxIO is used and the Multipath Diagnostic Program or Enhanced Support Facility 5.1 or

later is installed

When MPxIO is used for purposes other than described on the left

When the ETERNUS Multipath Driver or VxVM

is used

Solaris OS Solaris MPxIO Recommended

Linux Recommended (When not using

GRMPD)No Conversion (Default)

• For details on the firmware versions that support the MultipathDiagnostic Program, refer to "Multipath Diagnostic Program User'sGuide".

• An Oracle-brand Fibre Channel card driver may be used for FujitsuFibre Channel cards. Check which drivers are usable in the "Notes"chapter and the "Fibre Channel Cards that Require a Sun-brand Driver"section of the "ETERNUS Disk storage systems Server ConnectionGuide (Fibre Channel) for Oracle Solaris".

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

28 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 29: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

3.1.3.2 HP-UX

For HP-UX, perform the settings detailed in Table 3.5 and Table 3.6.

Table 3.5 Host Specific Mode setting for HP-UX

Table 3.6 Sense Code Conversion Pattern setting for HP-UX

3.1.3.3 AIX

For AIX, perform the settings detailed in Table 3.7 and Table 3.8.

Table 3.7 Host Specific Mode setting for AIX

Table 3.8 Reservation Conflict Response for Test Unit Ready setting for AIX

OS [Host Specific Mode] setting

HP-UX HP-UX Mode (SCC)

OSIntegrity VM

Used Not used

HP-UX Linux Recommended (When not using GRMPD) No Conversion (Default)

OS ETERNUS Disk storage system [Host Specific Mode] setting

AIX/VIOS

ETERNUS4000 models 300 and 500ETERNUS8000 models 700, 900, 1100, and 2100 AIX Mode

ETERNUS4000 models 400 and 600ETERNUS8000 models 800, 1200, and 2200

AIX Mode(Extended Address)

OS

ETERNUS MultipathDriver 2.0

used

ETERNUS MPIOfor IBM AIX2.0.xdriver used

VERITAS StorageFoundation

used

Single path configurationusing FJspio

PowerHA/HACMP used

PowerHA/HACMP not

used

AIX Conflict Response

Normal Response (Default)

Normal Response (Default)

Conflict Response

Normal Response (Default)

VIOS Conflict Response — — — —

Use of a PowerHA/HACMP cluster configuration only affects the"Reservation Conflict Response for Test Unit Ready" setting for single pathconfigurations using FJspio.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

29 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 30: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

3.1.3.4 Windows®

For Windows®, perform the settings detailed in Table 3.9 to Table 3.11.

Table 3.9 Reservation Conflict Response for Test Unit Ready setting for Windows®

For the host response Vendor Unique Sense Code, perform the settings detailed in Table 3.10.

Table 3.10 Vendor Unique Sense Code setting for Windows®

When a Windows® server and ETERNUS Disk storage system are multipath connected usingthe ETERNUS Multipath Driver or GR Multipath Driver, or single path connected using theETERNUS Device Driver or GR Device Driver, set the host response Sense Code ConversionPattern to [No Conversion].If the connection is performed without using the ETERNUS Multipath Driver, GR Multipath Driver,ETERNUS Device Driver, or GR Device Driver, set the host response Sense Code ConversionPattern to [Windows Recommended (When not using GR/ETERNUS MPD or Device Driver)].

OS MSCS or WSFC configuration

VERITAS Cluster Server configuration

All other configurations

Windows Server® 2008Windows Server® 2008 R2

Normal Response (Default) Normal Response

(Default) Normal Response (Default)Windows Server® 2003

Conflict ResponseWindows® 2000 —

ETERNUS Disk storage system OS

Connected server type

PRIMEQUEST 500/400 series

PRIMERGY, PRIMEQUEST 1000 series, Industry Standard Server

GR/ETERNUS Multipath Driver,GR/ETERNUS Device Driver

Standard Multipath Driver for Windows Server®

2008 (msdsm)

VERITASStorage

Foundation for

WindowsUsed Not used

ETERNUS4000 models 400 and 600ETERNUS8000 models 800, 1200, and 2200

Windows Server® 2008Windows Server® 2008 R2

No Report(Default) No

Report(Default)

No Report

(Default)

No Report (Default) No Report

(Default)

Windows Server® 2003

— —Windows® 2000 — —

ETERNUS4000 models 300 and 500ETERNUS8000 models 700, 900, 1100, and 2100

Windows Server® 2008Windows Server® 2008 R2

No ReportReport

(Default)

Report(Default) No Report

Report(Default)

Windows Server® 2003

— —Windows® 2000 — —

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

30 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 31: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

Table 3.11 Sense Code Conversion Pattern setting for Windows®

When connecting a Windows®-based VMware VCB Proxy server to the ETERNUS Disk storagesystem, and the LUNs are shared between the VMware VCB Proxy server and VMware ESXserver, the setting detailed in "3.1.3.6 VMware ESX" (page 33) should be used.

When connecting a PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series and ETERNUSDisk storage system, perform the settings detailed in Table 3.12 and Table 3.13.

Table 3.12 Vendor Unique Sense Code setting for Windows® (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)

Table 3.13 Sense Data Conversion Pattern setting for Windows® (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)

OS

GR/ETERNUS Multipath Driver,GR/ETERNUS Device Driver

Standard Multipath Driver

for Windows Server® 2008

(msdsm)

VERITAS Storage

Foundation for WindowsUsed Not used

Windows Server® 2008Windows Server® 2008 R2

No Conversion (Default)

Windows Recommended

(When not using GR/ETERNUS

MPD or Device Driver)

Windows Recommended

(When not using GR/ETERNUS

MPD or Device Driver)

Windows Recommended

(When not using GR/ETERNUS

MPD or Device Driver)

Windows Server® 2003—

Windows® 2000 —

Connected server typeSetting

Vendor Unique Sense Code

PRIMEQUEST 1000 series PRIMEQUEST 500/400 series No Report

Connected server typeSAN Boot configuration

Used Not used

PRIMEQUEST 1000 series PRIMEQUEST 500/400 series

Linux Recommended (When not using GRMPD)

Follow the settings for each environment

When the settings for each OS do not match the settings described above,perform the settings described above.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

31 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 32: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

3.1.3.5 Linux

For Linux, perform the settings detailed in Table 3.14.

Table 3.14 Sense Code Conversion Pattern setting for Linux

*1: VERITAS Volume Manager or device-mapper multipath should be used instead.

When connecting a PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series and ETERNUSDisk storage system, perform the settings detailed in Table 3.15 and Table 3.16.

Table 3.15 Vendor Unique Sense Code setting for Linux (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)

Table 3.16 Sense Data Conversion Pattern setting for Linux (PRIMEQUEST 1000 series or PRIMEQUEST 500/400 series connection)

OSETERNUS Multipath Driver

Used Not used (*1)

Red Hat Enterprise LinuxSUSE Linux Enterprise Server No Conversion (Default) Linux Recommended

(When not using GRMPD)

Connected server typeSetting

Vendor Unique Sense Code

PRIMEQUEST 1000 series PRIMEQUEST 500/400 series No Report

Connected server typeSAN Boot configuration

Used Not used

PRIMEQUEST 1000 series PRIMEQUEST 500/400 series

Linux Recommended (When not using GRMPD)

Follow the settings for each environment

When the settings for each OS do not match the settings described above,perform the settings described above.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

32 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 33: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

3.1.3.6 VMware ESX

When connecting a VMware ESX server to the ETERNUS Disk storage system, the settingsdetailed in Table 3.17 to Table 3.20 should be used. The required setting value depends on theETERNUS Disk storage system model and ESX version being used.

Table 3.17 Inquiry Standard Data Version setting for VMware ESX

Table 3.18 Sense Code Conversion Pattern setting for VMware ESX

Table 3.19 Host Specific Mode setting for VMware ESX

OS

Setting

Inquiry Standard Data Version

ETERNUS4000 models 300 and 500ETERNUS8000 models 700, 900, 1100, 2100

ETERNUS4000 models 400 and 600ETERNUS8000 models 800, 1200, 2200

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0) Version 05 (Default)

VMware Infrastructure 3 (ESX 3.0.x, ESX 3.5, ESXi 3.5) Version 04

ESX Server 2.5.x Version 05 (Default)

OS [Sense Code Conversion Pattern] setting

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)

Linux Recommended(When not using GRMPD)VMware Infrastructure 3

(ESX 3.0.x, ESX 3.5, ESXi 3.5)

ESX Server 2.5.x

OS

[Host Specific Mode] setting

ETERNUS4000 models 300 and 500ETERNUS8000 models 700, 900, 1100, 2100

ETERNUS4000 models 400 and 600ETERNUS8000 models 800, 1200, 2200

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0) VMware Mode Normal Mode (Default)

VMware Infrastructure 3 (ESX 3.0.x, ESX 3.5, ESXi 3.5) Normal Mode (Default)

ESX Server 2.5.x Normal Mode (Default)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

33 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 34: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

Table 3.20 Asymmetric/Symmetric Logical Unit Access for VMware ESX

When connecting a Windows®-based VMware VCB Proxy server to the ETERNUS Disk storagesystem, and the LUNs are shared between the VMware VCB Proxy server and VMware ESXserver, the setting detailed in Table 3.21 and Table 3.22 should be used.For VMware VCB Proxy details, refer to the VMware web-site.

Table 3.21 Inquiry Standard Data Version setting for Windows®-based VMware VCB Proxy server

Table 3.22 Host Specific Mode setting for Windows®-based VMware VCB Proxy server

When connecting a PRIMEQUEST 1000 series and ETERNUS Disk storage system in a SANBoot configuration, perform the settings detailed in Table 3.23.

Table 3.23 Sense Data Conversion Pattern setting for VMware ESX (PRIMEQUEST 1000 series connection)

OS

Setting

Asymmetric/Symmetric Logical Unit Access

ETERNUS4000 models 300, 400, 500, and 600

ETERNUS8000 models 700, 800, 900, 1100, 1200, 2100, and

2200

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)

ACTIVE-ACTIVE / PREFERRED_PATH ACTIVE / ACTIVE (Default)

VMware Infrastructure 3 (ESX 3.0.x, ESX 3.5, ESXi 3.5) ACTIVE / ACTIVE (Default)

ESX Server 2.5.x ACTIVE / ACTIVE (Default)

OS [Inquiry Standard Data Version] setting

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)

VMware Infrastructure 3 (ESX 3.5, ESXi 3.5)

Windows Server® 2008 used as a VCB Proxy server Version 05 (Default)

Windows Server® 2003 used as a VCB Proxy server Version 04

OS [Host Specific Mode] setting

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)

VMware Infrastructure 3 (ESX 3.5, ESXi 3.5)

Windows Server® 2008 used as a VCB Proxy server VMware Mode

Windows Server® 2003 used as a VCB Proxy server Normal Mode (Default)

Connected server typeSAN Boot configuration

Used Not used

PRIMEQUEST 1000 series Linux Recommended (When not using GRMPD)

Follow the settings for each environment

When the settings for each OS do not match the settings described above,perform the settings described above.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

34 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 35: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

3.1.3.7 PAN Manager

For PAN Manager, perform the settings detailed in Table 3.24 to Table 3.26.

Table 3.24 Inquiry Standard Data Version setting for PAM Manager

Table 3.25 Host Specific Mode setting for PAM Manager

Contact Egenera, Inc. for guest OSes supported by PAN Manager.

Table 3.26 Sense Code Conversion Pattern setting for PAN Manager

3.1.4 Registering the WWNs of the Accessing Fibre Channel Cards or Converged Network Adapter Cards (Registering the WWNs)

Register the WWN of each Fibre Channel card or Converged Network Adapter card installed inthe server that will access the ETERNUS Disk storage system. At the same time, set the hostresponse numbers registered in "3.1.3 Setting the Host Responses" (page 28) to accept theseWWNs.

WWN registration combines with the Host Affinity settings (described later) to limit which serversare allowed to access which ETERNUS Disk storage system LUNs.

OS [Inquiry Standard Data Version] setting

PAN Manager Version 05 (Default)

OS ETERNUS Disk storage system[Host Specific Mode] setting

Guest OSVMware ESX used

Guest OSVMware ESX not used

PAN Manager

ETERNUS4000models 300 and 500ETERNUS8000models 700, 900, 1100, and 2100

VMware Mode Normal Mode (Default)

ETERNUS4000models 400 and 600ETERNUS8000models 800, 1200, and 2200

Normal Mode (Default)

OS [Sense Code Conversion Pattern] setting

PAN Manager Linux Recommended (When not using GRMPD)

When a server-side Fibre Channel card or Converged Network Adaptercard is replaced, the WWN of the replacement Fibre Channel card orConverged Network Adapter card must be re-registered to the ETERNUSDisk storage system.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

35 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 36: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.1 Common Settings

P

3.1.5 Defining the Relationship between the Accessing Fibre Channel Cards or Converged Network Adapter Cards and the LUN Groups (Allocating the Host-Affinity Groups)

Allocate Host-Affinity Groups for each server connected to the ETERNUS Disk storage system.Allocate the WWN of each server to an Affinity Group and specify the accessible LUNs. This setsthe access restrictions from each server to the ETERNUS Disk storage system.

• To recognize a LUN which has the same configuration for multiple FibreChannel cards or Converged Network Adapter cards, such as inmultipath and cluster configurations, add settings to assign these FibreChannel cards or Converged Network Adapter cards to the same Host-Affinity Group.

• If the one-to-one relationship between the WWNs and Fibre Channelcards or Converged Network Adapter cards cannot be determined, theHost-Affinity Group settings may not be allocated correctly.In this case, try various settings until the server is able to recognize theETERNUS Disk storage system logical disks.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

36 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 37: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.2 OS Specific Settings

P

3.2 OS Specific Settings

Some settings are not required for some server OSes and/or connection configurations.Check the various cases described below, and perform any required settings.

3.2.1 Setting the CA Reset Groups

If the system configuration matches any of the "System configuration that requires the resetgroup setting" in the following table, every ETERNUS Disk storage system CA port that connectsto the given server's access paths must be assigned to the same reset group.For system configurations other than the following, use the default settings.

*1: When multiple ESX servers share ETERNUS Disk storage system LUNs, any ETERNUS Disk storagesystem CA port that connects a shared LUN to an ESX server must be assigned to the same resetgroup, whether multi-paths are used for the ESX servers or not.

Server OS System configuration that requires the reset group setting

Solaris 10 OSSolaris 9 OSSolaris 8 OS

• Sun Cluster configuration

AIX • Single path configuration using FJspio for a PowerHA or HACMP cluster

Windows Server® 2003Windows® 2000

• MSCS configuration

VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0), VMware Infrastructure 3 (ESX 3.0.x, ESX 3.5, ESXi 3.5), ESX Server 2.5.x

• Multipath configurationor

• Multiple ESX servers share ETERNUS Disk storage system LUNs (*1)

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

37 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 38: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

Chapter 3 ETERNUS4000 and ETERNUS8000 Connection Settings > 3.3 Checking the WWNs

P

Example: When multiple ESX servers share ETERNUS Disk storage system LUNs, CM#0 CA#0Port#1 and CM#1 CA#0 Port#1 must be assigned to the same reset group, even forsingle-path configurations.

3.2.2 Setting the Sub System Parameters (for HP-UX only)

For HP-UX connection, select the [Disable Load Balance] checkbox in the "Mode 1" section ofthe "Set Sub System Parameters" screen. This prevents sense responses that require accessretries from being issued when the ETERNUS Disk storage system is in an overload state.

3.3 Checking the WWNs

Use ETERNUSmgr to check the WWN of each ETERNUS Disk storage system CA port. Theyare required to connect the ETERNUS Disk storage system to the server.

Server#1 Server#2

Fibre Channel Switch#1 Fibre Channel Switch#2

HBA#1 HBA#1

Affinity-Group

CM#0CA#0Port#1

CM#1CA#0Port#1

For HP-UX server, improper logs may be recorded unless sense responseis restricted. Therefore, select the [Disable Load Balance] checkbox.(Sense response should be restricted.) Note that changing the [DisableLoad Balance] setting does not affect on non-HP-UX servers.

Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

38 Copyright 2013 FUJITSU LIMITED

3AM-2822-09ENZ0

Page 39: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk

• The content of this manual is subject to change without notice.• This manual was prepared with the utmost attention to detail.

However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual.

• Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

• The content of this manual may not be reproduced or distributed in part or in its entirety without prior permission from Fujitsu.

ETERNUS Disk storage systemsServer Connection Guide (Fibre Channel)ETERNUS Disk Storage System Settings

P3AM-2822-09ENZ0

Date of issuance: October 2013Issuance responsibility: FUJITSU LIMITED

Page 40: ETERNUS Disk storage systems Server Connection Guide ...storage-system.fujitsu.com/global/manual/diskarray/pdf/p3am-2822... · Server Connection Guide (Fibre Channel) ETERNUS Disk