Release Information

ZFA-F / MES-F / iClient / Webportal

Changes and new features

from version V10.11 to V10.20

Copying abstracts resp. the total documentation needs absolutely the authorization of the company ITF-EDV GmbH. ITF-EDV Fröschl GmbH, 93194 Walderbach

Table of contents

Extensions/ new features/ changes in version 10.20 ........................................................................ 4

New modules ................................................................................................................................... 4 Modified modules ............................................................................................................................ 5 Errors fixed in this version .............................................................................................................. 7

Extensions/ new features/ changes in version 10.19 ...................................................................... 12

New modules ................................................................................................................................. 12 Modified modules .......................................................................................................................... 13 Errors fixed in this version ............................................................................................................ 15

Extensions/ new features/ changes in version 10.18 ...................................................................... 26

New modules ................................................................................................................................. 26 Modified modules .......................................................................................................................... 26 Errors fixed in this version ............................................................................................................ 30

Extensions/ new features/ changes in version 10.17 ...................................................................... 41

New modules ................................................................................................................................. 41 New released resources .................................................................................................................. 41 Modified modules .......................................................................................................................... 42 Errors fixed in this version ............................................................................................................ 44

Extensions/ new features/ changes in version 10.16 ...................................................................... 51

New modules ................................................................................................................................. 51 Modified modules .......................................................................................................................... 52 Errors fixed in this version ............................................................................................................ 53

Extensions/ new features/ changes in version 10.15 ...................................................................... 61

New modules ................................................................................................................................. 61 New released resources .................................................................................................................. 62 Modified modules .......................................................................................................................... 62 Errors fixed in this version ............................................................................................................ 65

Extensions/ new features/ changes in version 10.14 ...................................................................... 75

New modules ................................................................................................................................. 75 New released resources .................................................................................................................. 75 Modified modules .......................................................................................................................... 75 Errors fixed in this version ............................................................................................................ 79

Extensions/ new features/ changes in version 10.13 ...................................................................... 91

New modules ................................................................................................................................. 91

2

New released resources .................................................................................................................. 92 Extended modules .......................................................................................................................... 92 Modified modules .......................................................................................................................... 94 Errors fixed in this version ............................................................................................................ 95

Extensions/ new features/ changes in version 10.12 .................................................................... 111

New modules ............................................................................................................................... 111 New released resources ................................................................................................................ 111 Extended modules ........................................................................................................................ 112 Modified modules ........................................................................................................................ 115 Errors fixed in this version .......................................................................................................... 117

Extensions/ new features/ changes in version 10.11 .................................................................... 133

New modules ............................................................................................................................... 133 New released resources ................................................................................................................ 134 Extended modules ........................................................................................................................ 134 Modified modules ........................................................................................................................ 135 Errors fixed in this version .......................................................................................................... 136

3

Extensions/ new features/ changes in version 10.20 (Released on: 24/11/2015)

Extensions/ new features/ changes New modules 22/5.16 Landis+Gyr: ZMG/ZFG (IEC1107) New device driver Landis+Gyr: ZMG/ZFG (IEC1107) Module 22/5.16 Landis+Gyr: ZMG/ZFG (IEC1107) is released. Find further information in the manual "dd_landis_gyr.chm" under "S650 / ZMD/ZFD / ZMG/ZFG according to VDEW" > "General". ID: 10455 22/5.17 Landis+Gyr: S650 (IEC1107) New device driver Landis+Gyr: S650 (IEC1107) Module 22/5.17 Landis+Gyr: S650 (IEC1107) is released. Find further information in the manual "dd_landis_gyr.chm" under "S650 / ZMD/ZFD / ZMG/ZFG according to VDEW" > "General". ID: 9599 70/6 Interface ADDAX IMS Milestone 2: Web service interface for transmitting measuring data Support of the communication system "ADDAX IMS": The reading of ADDAX device was extended by the following functionality: - Extension of the Web service interface by the action "disconnect" and "switch on". - Support of the monitoring values "Numbers of sent SOAP calls to ADDAX IMS (Error)/(Total)". - Billing data reading from the database (Action "Meter reading (ADDAX IMS)"). - Action "Reading event log". You can find further information in the manual "dd_diff.chm" under "Interface ADDAX IMS" > "General" and "ADDAX meters". ID: 10538

4

Modified modules 21/26.2 EDIFACT/MSCONS interface edi@energy export Support of MSCONS version 2.2e and corresponding APERAK, CONTRL and OBIS version Support of MSCONS version 2.2f ID: 10976 22/12.13 ELGAMA: GAMA 300 G3B Reading event log "G3B" Support of the changed event log format Processing number: 2015-000933 ID: 11194 22/20.3 Reallin: E3005-S16 (DLMS) Tariff download device driver Reallin: E3005-S16 (DLMS) The device action "Tariff download" was added. ID: 10468 System basis All language DLL files are to be installed by the installation So far only the language resources which were required for the installed language were installed during the installation. From now all available language files (de-DE, el-GR, en-US, fr-FR, lv-LV, pt-BR) are installed at each installation. This change was made to prepare the multilingual installation and has no effect at the moment. ID: 10845 Logging of the system start at services Single steps of the starting process are written into a separate start-up log file, if you start the services "Communication Service", "Control Center" "IP-T Master", "Soap Instance Manager" and "ZFA Applications Server", ID: 10822 Start of manual actions via groups (Level 1) Now, you can also transfer devices and device groups for the implementation of manual actions. You can find further information in the manual "zfa_f.chm" under "Device management and communication" > "Device management" > "Reading" > "Manual reading" > "Execute actions manually". ID: 10808

5

Change of the methodology for collecting order readings from the control center in ZFA-F. Now, you can select between the following two algorithms for collecting reading results for the communication system SCS: * OLD: Automatic clients request certain reading results from the SCS Disadvantage: The control center receives very many requests if there any automatic clients. Many requests do not supply a result since the readings were not executed till that moment. * NEW: Automatic clients request desired results at the SCS Advantage: As long as reading results are existing at the SCS, all requests of the automatic clients are executed. Furthermore, no automatic client reserves any reading orders. This leads to a more equal workload of the automatic clients. You can find further information in the manual "zfa_f.chm" under "Automatic operation schedule control" > "Automatic reading" > "Multi automatic operation with automated processing". * and in the manual "config.chm" under "System configuration" > "ZFA" > "Communication" > "SCS". ID: 9619 Automatic restart of the process to improve reliability All services are divided into a parent process and a child process. The parent process includes the Windows functionalities and improves the reliability of the child process. The child process contains the actual functionality of the service. You can find further information in the manual "zfa_f.chm" under "Montoring" > "System monitoring" > "Monitoring values". ID: 5865 Calculating consumptions at meter values The suppression of the "L" only acts at real measuring gaps, if the gap consists only of 0C-values. ID: 10915 Export/Import of ZFA-F user/user groups and their rights Now, the export/import of users and user groups is possible via data transfer. ID: 10898

6

Errors fixed in this version Data management 30/2 Basic load profile calculation Missing column <name> for details The column "Data channel name" was missing at selection of details, if substitute values were generated with the method "Copy". Processing number: 2015-000909 ID: 10632 Data transmission 16/0 Configurable export Error message at start of a script export function The error message "Unable to open database" occurs if an export script without report file is started. Now, it´s checked if a report file is indicated at the execution of an export script. ID: 11226 iClient 60/x Internet module / iClient Missing functions at MouseOver No values are displayed if the cursor is moved over a bar of the load profile channel. Processing number: 2015-000889 ID: 10567 Error "Search" at the iClient The search at the iClient takes very long and the channels under a metering point were not displayed. Now, the search was accelerated while a newly created interface function is used. The search supplies channels under a metering point link as well. Processing number: 2015-000603 ID: 10020 Menu bar "additional information" is displayed incorrectly The menu bar "additional information" was located too far to the right margin, therefore the information were displayed incorrectly. Processing number: 2015-000888 ID: 10566

7

Too small bar width of the load profile The bar chart was displayed incorrectly. Instead of bars only lines were displayed and the first value was missing. Processing number: 2015-000885 ID: 10562 SCS 29/0 Smart Communication Server (SCS) 29/0 Smart Communication Server (SCS) If a new communication profile was added or an existing profile was deleted, the file "settingscache.xml" was not refreshed anymore. Processing number: 2015-001227 ID: 11485 Incorrect transmission of the SCS master data at switch to the standby control center If there is a manual or automatic switch to the standby control center during the configuration "central SCS data base schema" was active, the SCS master data were not loaded from the central SCS data base schema, but from the schema which executes the switch. As a consequence, no readings could be executed. Processing number: 2015-001078 ID: 11150 Communications service crashes when reading an object list The access to the file "settingscache.xml" was not multi-thread compatible. Therefore, the communication service crashes. Processing number: 2015-000973 ID: 10927 State information gets lost at dial-up at cascading The complete Layer-7 driver was deleted at cascaded readings if the connection was hold at the SCS communications service. Device drivers, which have memorized the open-method status, lost them therewith. Now, the device driver instance is reused at cascaded devices to retain internal status. Processing number: 2015-001009 ID: 7186

8

29/12 Virtual COM port client (IptVcp) Initialization of the COM ports failed A change of behavior was implemented at the IptVcp. It is not possible to select other addresses if a COM port is set with a predefined phone number. The connection is reset each time if a dialing attempt is starting if there is no predefined phone number at the COM port. Processing number: 2015-000731 ID: 11072 System basis 30/5.2 Plausibility check – checking billing data Plausibility check "MP 5" reports error status "P" even the number of resets are correct. The status "P" was not set correctly at the execution of check "MP5". Processing number: 2014-001234 ID: 7387 31/6 Dynamic View MSCONS export is not editable via dynamic relation. If there were changes in the dynamic view at the MSCONS export, they were not saved. Now, the saving works also in the dynamic view. Processing number: 2015-001234 ID: 11510 System basis E-mail transfer with Crystal Reports does not work after the update to V10.6 Up to ZFA-F version 10.5 it was possible to send the created report directly via MAPI in Crystal Reports. This functionality was restored. The sending by e-mail can be started via a button in the toolbar of Crystal Report. At this the standard e-mail client is opened and the report is added as PDF file. Processing number: 2013-000361 ID: 2087 Application crashes often ZFA-F crashed sometimes if you switched from the device view or customer view to the action view. Processing number: 2015-000345; 2015-000302 ID: 9163 After exit of the ZFA-F the error message "ZFA has stopped working" occurs ZFA-F crashes at exit, if the option "ZFA/COMMUNICATION/SCS/EXTERNAL_USER" was selected. Processing number: 2015-000123 / 2015-000438 ID: 11109

9

Status processing at meter data maintenance allows arbitrary characters So far all kinds of characters could be used if the status field at the meter data maintenance was edited. The check for invalid statuses was carried out when the meter data maintenance was executed. Now a check is executed at each status character. Processing number: 2015-000130 ID: 8285 ZFA-F device drivers electricity 20/4.6 Landis + Gyr: FCL Incorrect import at request of the FCL At reading of two devices with one reading via COM-F, the requests were sent to the second device again. Processing number: 2015-000971 ID: 11375 22/17.1 PRI: SprintXP Ignoring of certain messages at event log reading Log file messages with the following main codes are not imported: 11, 12, 13, 14, 15, 19, 24. Processing number: 2015-001136 ID: 11212 22/18.1 Schneider: ION 8600 Reading ION8600 over one month fails At the reading of an ION8600 it could happen that reading was canceled after one retry. The reason was the wrong assignment of the second response, because after a retry the device could response twice. Processing number: 2015-000666 ID: 11024 22/3.11 IskraEMECO: ME382/MT382 (DLMS) Fraud-event log could not be read The Fraud log was also not imported if a time frame without messages in the standard event log was indicated at the reading. Now, the log files are always added, independent from the time frame. Processing number: 2015-001051 ID: 11280 Undefined time stamps are not treated correctly. Undefined time stamps were displayed as "??????????" in a billing data record. Now undefined time stamps are set to "00000000000000". Processing number: 2015-001107 ID: 11126

10

Time frame was determined incorrectly The time frame was determined incorrectly at a schedule-controlled event log reading. Now, the time frame begins with the last device message in the database or with the installation date. Processing number: 2015-001051 ID: 11112 22/8.4 SyM2 standard SyM² push data are imported incorrectly on the switching day of daylight saving time/standard time. The check for maximum difference of the SyM² seconds index fails on the switching day of daylight saving time/standard time. Processing number: 2015-001015 ID: 11169 ZFA-F device drivers gas 24/8.11 Wieser MRG 2100 Optimization of the communication process It could happen that device did not accept the password if a MRG3100 or a MRG2100 was read via the Wieser protocol. This problem could be regulated by the new device driver setting "SEND_PASSWORD_DELAY". Processing number: 2015-001008 ID: 10937 24/8.2 Wieser: MRG2200 Actual fault value could not be read at DSfG devices The last load profiles value was not stored at channels of interference. Processing number: 2015-001196; 2015-001223 ID: 11423 ZFA-F device drivers different energy types 23/1.1 Dr. Neuhaus: ZDUE-MOD/ISDN/GSM-PLUS Login command is not detected The structure of the device drivers was revised. Now, requests via meter modems with 7 data bits works, too. ID: 10826

11

Extensions/ new features/ changes in version 10.19 (Released on: 13/10/2015) Extensions/ new features/ changes New modules 22/20.3 Reallin: E3005-S16 (DLMS) New device driver Reallin: E3005-S16 (DLMS) Module 22/20.3 Reallin: E3005-S16 (DLMS) is released. Find further information in the manual "dd_itf.chm" under "E1000-03 / E3005-S16 / E3010" > "General". ID: 9903 22/24.1 SANXING: SX1A1/SX5A2 (DLMS) New device driver SANXING: SX1A1/SX5A2 (DLMS) Module 22/24.1 SANXING: SX1A1/SX5A2 (DLMS) is released. Find further information in the manual "dd_diff.chm" under "SANXING" > "SX1A1/SX5A2" > "General". ID: 9253 28/17.1 METRA Energie-Messtechnik: ERW 700 (Modbus) Device driver: METRA Energie-Messtechnik: ERW 700 (Modbus) Module 28/17.1 METRA Energie-Messtechnik: ERW 700 (Modbus) is released. Find further information in the manual "dd_diff.chm" under "METRA Energie-Messtechnik" > "ERW 700" > "General". ID: 5997 31/8 Interface Vodafone GDSP service Interface Vodafone GDSP service The administration and monitoring of SIM cards can be automated by connecting the ZFA-F system to the GDSP service by Vodafone. The following functions are available: * Activating and deactivating SIM cards * Requesting the transmitted amount of data SIM card Restrictions: * Requesting the transmitted amount of data is only possible for the integration period "1d". For this purpose the modems have to be disconnected from the radio network at least once a day. Find further information in the manual "dd_common.chm" under "SIM card" > "General". ID: 6628

12

70/6 Interface ADDAX IMS Milestone 1: Web service interface for transmitting measuring data Module 70/6 Interface ADDAX IMS is for released for milestone 1. Find further information in the manual "dd_diff.chm" under "Interface ADDAX IMS" > "General" and "ADDAX meters". ID: 6365 Modified modules 21/16 Standard measuring data import / export Extension by option (export active / inactive data channels) The export scripts "STDM_EXP.SCT" and "STDM_EXP_StateControl.sct" were extended by the option for filtering the data channel status. Processing number: 2014-001370 ID: 7859 21/29.2 EDIFACT/MSCONS interface Edi@Energy Export Supplying Z-number at MSCONS export It is possible to assign a Z-number data channel at the export of energy values for the type of energy "Gas". Find further information in the manual "if_msc1.chm" under "Export" > "Calorific value and Z-number". Processing number: 2015-000723 ID: 10659 21/R00 Raw data import Raw data import DL230 The device driver DL230 was added to the raw data import (Skalar format). Processing number: 2015-000791 ID: 10364 22/3.11 IskraEMECO: ME382/MT382 (DLMS) Device dialog: displaying the options of the communication profile A new section "Communication profile" was added to the tab sheet "Communication mode" in the device dialog. This section is only available if the communication mode SCS is selected. This section displays the settings of the selected communication profiles. Processing number: 2015-000497 ID: 9643 ME382/MT382 (DLMS): Setting up protocol separately for each communication mode via configuration profile The settings of the communication protocol can be defined separately for each communication mode by using different communication profiles. Processing number: 2015-000497 ID: 9508

13

Collective ticket: Setting up protocol separately for each communication mode via configuration profile The settings of the communication protocol can be defined separately for each communication mode by using different communication profiles. Processing number: 2015-000497 ID: 9641 22/8.4 SyM2 standard Log message if IP-T timeout has reached 30 minutes Now a message is written to the event log if the IP-T timeout exceeds 30 minutes. Processing number: 2015-000816 ID: 10546 93/1 Standard interface for master data transfer ZFA-F Move or link devices under the standard device group "ITF-EDV master data transfer" Now the standard group "ITF-EDV Master Data Transfer" is only used for new elements. Existing elements remain in their original group if neither the import file nor the options dialog contains a corresponding group. ID: 10221 Extend master data transfer by further fields The master data import was extended by the fields "Firmware name", "Firmware version" and "Hardware ID". ID: 10316 96/0 Interface for collection of measuring data Function "GetResultValues: Returning data for the requested time frame Now the behavior of the interface "GetResultValues" regarding the evaluation of prevalues of a billing data record can be controlled. ID: 10222 System basis Calculating consumptions at meter values At the calculation of consumptions from meter values, the first consumption after a measuring value gap was calculated on the basis of the difference of the meter value before the gap and the new meter value. Additionally the status L was added to this value. This function can be deactivated via the central configuration if you do not want to calculate a consumption but a 0C value. Find further information in the manual "config.chm" under "System configuration" > "ZFA-F" > "Load profile" > "Counter values". ID: 10549

14

Dynamic opening of helps in web applications depend on the installed language The help files are opened dynamically since not all help files are translated to the corresponding language. It is checked whether the language is existing. If the help is not available in the corresponding language, the English help is opened instead. If the English version of the help is not available as well, the German help is opened. ID: 10640 Installation of all helps in all languages By means of the installation all existing help files are installed in all translated languages. ID: 9316 Splash screen at the start of ZFA-F If you start ZFA-F a splash screen is displayed before you log in. This page displays the current step and a loading bar. If you double-click the start screen a list with all executed steps is opened. The single steps including the corresponding time stamps are written to the log file "zfa_startup.logf". ID: 2550 Windows conform installation The ZFA-F installation was matched to the Microsoft standards for installation of Windows programs. This new installation method is suggested as standard at new installations. As before, you can select the old method but this should only be used if it is mandatory necessary. Find further information in the manual "install.chm" under "ZFA-F" > "Types of installation". ID: 5133 Errors fixed in this version Automatisms 18/0 Macro control Assignment of data channel link deleted - macro fails The macro "Recalculate virtual data channels" was marked as incorrect and the recalculation was cancelled if a data channel link was deleted in the meantime (e.g. in a second view) and if the macro view was not refreshed before the macro was executed. Now deleted data channel links are skipped and the process goes on. Processing number: 2015-000749 ID: 10623

15

18/1 Macro for automatic grouping Device is grouped even if the criterion "Devices for which reading data are existing" is selected At the grouping of unfound devices, devices were grouped if the billing data contained records with another meter reading reason as well as records with the selected meter reading reason even though the grouping criterion "Devices for which reading data are existing" was selected. Processing number: 2015-000755 ID: 10379 Database structure System basis Database update, MSSQL (Collation Latin1_General_CS_AS) supplies error messages Errors occurred in the event log at a database update of an SQL Server database with the setting "Collation Latin1_General_CS_AS". ID: 10406 Performance problem due to too many rollbacks Too many transactions were retracted (rollbacks). The number of rollbacks was minimized. Processing number: 2014-001254 ID: 7361 Data import 21/R00 Raw data import Import load profile DL230 - possible with several channels If there were several load profile channels created at a DL230, an error message was logged at the raw data import with Skalar format 1. This error occurred if the import file only contained data for some but not for all created channels. Processing number: 2015-000791 ID: 10904

16

Data management 30/16 Generation of substitute values by direct comparison Overwrite existing status values (PIE or IE) does not work for the method "Copy" at a comparison meter. At the substitution method "Copy", temporary values were not interpreted as missing values even though status "I" was indicated at the option "Values with status combination". Now the selected status combination works correctly even if status "I" is contained. Processing number: 2015-000380 ID: 9062 30/27 Generation of substitute values for register values from load profiles Transformer constants are not considered at generating substitute values (Register values from load profile) The transformer constants were not considered at the determination of substitute values. Now the generation of substitute values provides an additional option "Secondary values". If this option is inactive, the transformer constants of the load profile channels are considered. ID: 6003 30/5.10 Plausibility check according to G 685 standard Plausibility check consistency check according to G 685 The consistency check according to G685 calculated an incorrect relative deviation if the upper limit was 0. Now the consistency check according to G685 calculates a relative deviation of 100% if the upper limit is 0. Processing number: 2015-000787 ID: 10377 Data transmission 16/0 Configurable export Incorrect export If there was no element of the type "STORE_DEVICE", "DATACHANNEL" or "CUSTOMER" in the selection of the report, the data of the previously executed export were used. Since the tables that are used in the script are listed under the section "INIT" and the key "PRINTER_TABLES", the tables are always adjusted. Processing number: 2014-000678 ID: 10393

17

21/29.1 EDIFACT/MSCONS interface Edi@Energy import MSCONS import fails The import of carbon dioxide and nitrogen load profile data failed. All gas ID codes with the unit "mol%" can now be imported. Processing number: 2015-000872 ID: 10570 iClient 60/x Internet module / iClient Missing value in the load profile chart (y axis) The bar chart was displayed incorrectly. Instead of bars only lines were displayed and the first value was missing. Processing number: 2015-000886 ID: 10766 Incorrect export (send e-mail) If you select a data channel with an integration period of 1440 min (1 day), values that do not correspond to the selected date are entered at the CSV export. Processing number: 2015-000887 ID: 10764 Installation System basis Adjustment of the applications for release of the Windows Server 2012 All applications can be installed centrally or distributed ID: 10203 Clearing and refreshing the files "zfalogon.cmd" and "ZfaTmsrv.key" Since the Sybase databases were discontinued, the files "zfalogon.cmd" and "ZfaTmsrv.key" had to be updated. The file "zfalogon.cmd" is updated correspondingly and the file "ZfaTmsrv.key" is replaced by the files "ZfaTmsrv.key_32" and "ZfaTmsrv.key_64". ID: 10644 The configuration file of the Webportal shall not be imported again at an update. Due to changes of the configuration file for the Webportal, the configuration file is saved in case of an update installation but it is not imported again since it would overwrite the new configuration file. For that reason the configuration wizard has to be executed at if the Webportal is started. ID: 11014 Terminal server installation with Repair causes problems The LIP path war not transferred correctly at an update installation. For that reason ZFA-F could not be started anymore. ID: 10105

18

Interfaces for MES-F 40/x Interface for mobile meter reading (MES-F) Missing settings at manual reading If only the device drivers "Manual reading" and "IEC1107 (without LP)" were activated, it was switched to limited license settings and only some fields were available. Now, the limited license settings are only applied if the license is expired. Processing number: 2014-001315, 2014-001328, 2015-000018 ID: 10425 System basis Error at determining the FTP directory A user-depended subdirectory was not considered at the FTP data exchange. Processing number: 2015-000869 ID: 10522 SCS 29/0 Smart Communication Server (SCS) The settings from DEVICE_CAPABILITIES are not applied with communication profiles If a device that used DEVICE_CAPABILITIES in its options was read via a communication profile, the default settings were applied instead. The reason for this problem was the incorrect update of the file "settingscache.xml" at the SCS. Processing number: 2015-000976 ID: 10924 XML parsing, Threading problem with the class "JobInfo" During the communication the SCS communications service failed sporadically. Processing number: 2015-000789; 2015-000792 ID: 10147 Master data transfer 93/1 Standard interface for master data transfer ZFA-F Master data transfer Format 1: The physical address not defined at meter device of the data channels If the physical address of a meter was changed by means of a master data transfer, the address at the meter device of the data channel was not adjusted correctly. Now, the data of the measuring device are updated. Processing number: 2015-000786 ID: 10328

19

System basis 19/11 Central administration of configuration files Error at initializing the file "zfa_f.ini" The file "zfa_f.ini" could not be accessed if a network share without a further subdirectory (e.g. \myPC) was indicated as global or local configuration path. Processing number: 2015-000912 ID: 10635 System basis Supplied callback containers have to adjusted The callback containers were adjusted. If local and global COM-F configuration files are used, the containers of the callback directory which is used by the configuration files have to be replaced by the callback containers of the installation directory. ID: 10452 Incorrect colors for representing tariffs The colors of the tariffs in the data view were not displayed correctly anymore if the selected time was tool large for the view. Processing number: 2015-000079 ID: 8095 Data view, Measuring data view If a large user-defined time frame was selected, the maximum values of a load profile channel were not displayed correctly in the line chart of the data view . Processing number: 2015-000386 ID: 10977 Error at creation of the reading statistic At the reading statistic, the connection to the print database could not be established for certain database types. The report could not be printed. The error message "...Database provider code: 208..." was supplied. Processing number: 2015-000767; 2015-000768; 2015-000772 ID: 10314 Error at printing from profile view Printing a report via the printing templates "Billing data" or "Raw data" in the profile view failed. Following error message was supplied: "Unable to read data from database. Details: [Database provider code: 208 ] ...". The error was removed by adjusting the reports PRINT02.RPT and PRINT02R.RPT. Processing number: 2015-000865; 2015-000882; 2015-000931 ID: 10724

20

Installation of database-oriented software dongle The description of how to activate a license for software-oriented software dongle was missing in the installation manual. Since the activation of the license is already described centrally, only a link to the description was added to the installation manual. Find further information in the manual "zfa_f.chm" under "System technology/Administration" > "Licensing" > "Software dongle". Processing number: 2015-000560 ID: 9622 Conversion settings not updated So far the INI file including the current conversion settings was created under the global INI path. This failed there is no writing access available at the terminal server operation. Now, the INI file including the current conversion settings is created under the local INI path. Processing number: 2015-000695 ID: 10274 Meter data maintenance – edit data: Editing status allows arbitrary characters. So far all kinds of characters could be used if the status field at the meter data maintenance was edited. The check for invalid statuses was carried out when the meter data maintenance was executed. Now a check is executed at each status character. Processing number: 2015-000130 ID: 8285 Restart MES-F version 10.15 After a restart of the HHU, MES-F was closed at the first start. Only certain handhelds by the manufacturer "Motorola" were affected. Processing number: 2015-000060 ID: 8174 Problems with data view (chart) If you have switched from a line chart to a bar chart and opened the data view at a load profile channel, the chart was not displayed anymore and a white space was displayed instead of the chart. Invalid font information of the chart are not saved to the file "zfasheet.ini" anymore. Processing number: 2015-001024 ID: 10938 Logging at moving or cutting and pasting a device There was no entry in the event log if a device was moved to another device group. Thus, it was impossible to find devices that were moved. Now a log message is written if a device or a device group is moved. Processing number: 2015-000694 ID: 10026 SQL evaluation does not work with current version Errors occurred at the processing of SQL statements in the dynamic view. The SQL statements have to be adjusted in order to remove those errors. Find further information in the manual "zfa_f.chm" under "Introduction" > "Dynamic view" > "SQL definitions". Processing number: 2015-000739 ID: 10331

21

Starting ZFA-F fails The starting process of ZFA-F was cancelled without any error message and log entry if the field TYPE in the table SYSTEM_CLIENT was only filled with "A". Now an entry is written to the file log. Processing number: 2015-000864 ID: 10510 Behavior of ZFA-F at cascaded user groups The description of user rights at cascaded devices was missing in the manual for ZFA-F. The manual was extended by the description and a corresponding example. Find further information in the manual "zfa_f.chm" under "Introduction" > "User administration" > "Symbols". Processing number: 2015-000757 ID: 10231 Inserting values is incorrect If you were in the the load profile view and used the CTRL button to mark two quarter of an hour values that were not successive, all data were displayed instead of only the both values that were selected if you wanted to edit the data via the context menu > "Data" > "Edit". Processing number: 2014-000892 ID: 6518 ZFA-F: Symbol of the current view is not refreshed If the view in ZFA-F was switched, the symbol next to the title of the view was not refreshed. Processing number: 2015-000836 ID: 10125 Changes in the field "Additional data" of a subordinated device Under certain conditions the wrong entry was opened in the tree structure after additional device data were saved (e.g. link to another place). Now the device that was edited remains active in the tree structure. ID: 10150 Time series administration 95/Ox Shared time series database Crash at import at prevoius data change in ecount ZFA-F failed if existing load profile data were changed at the common data pool in ecount and data were read in the same time frame afterwards. ID: 10460

22

ZFA-F device drivers electricity 22/12.13 ELGAMA: GAMA 300 G3B Reading G3B does not work at devices with firmware version B7Q5v32n Reading a G3B meter with the firmware version "B7Q5v32n" failed and the message "Error transmitting the logical device name" was supplied because the device driver did not support the response format. Now the data format for reading the logical device name is supported. Processing number: 2015-000844 ID: 10474 22/16.2 EDMI: Mk7C Reading quality data fails The evaluation of the Sag/Swell event log of the MK7C/MK10A was revised. If the end of a phase failure is supplied even if there was no beginning of a phase failure, then this event is not evaluated. However a phase failure is logged. If all three phases fail, the register ID 129.33.0 is written to the billing data record. Processing number: 2015-000811 ID: 10716 22/17.1 PRI: SprintXP Event log reading fails The event log reading of PRI devices failed if the format LBP was used. Processing number: 2015-000847 ID: 10475 22/2.14 EMH: EM4TII (IEC1107) Automatic switch of the time zone Deactivating the checkbox "with daylight saving/standard time switch" in the device dialog caused an automatic switch of the time zone. Now the time is not changed anymore after the checkbox is deactivated. Processing number: 2015-000884 ID: 10704 22/21.1 SATEC: EM720/ EM720T - functionality 1 Billing data of current readings differ by the factor 10 compared to automatic resets. Cumulative values of an EM720 were supplied without considering the scaling factor at the calculation. Processing number: 2015-000866 ID: 10590

23

22/23.1 Holley: DDSD285 (DLMS) Holley: DDSD285 (DLMS) Setting date / time incorrect The meter did not accept the command for setting the time. Now the time can be set if the correct weekday is selected. Processing number: 2015-000877 ID: 10841 22/5.5 Siemens/Landis & Gyr: ZMD (DLMS) Error message "Incorrect protocol flow" at missing prevalues If anew meter did not contain any prevalues in the billing data record, the error message "Incorrect protocol flow" was supplied. Now the current record is imported with the status "No data existing" if there are not prevalues available. Processing number: 2015-000870 ID: 10544 22/6.2 SLB/Actaris: SL7000 The first value of a load profile reading is not imported The first value of a day was not imported. Processing number: 2015-000662 ID: 10349 System basis Storing of meter number with "-" not possible (MES-F) A device ID could not be imported if its reading data contained characters that could not be registered by ZFA-F. Now the MES-F setup offer possibilities to remove characters from the device ID. Processing number: 2015-000689 ID: 10533 Storing of meter number with "-" not possible (ZFA-F) A device ID could not be imported if its reading data contained characters that could not be registered by ZFA-F. Now the MES-F setup offer possibilities to remove characters from the device ID. Processing number: 2015-000689 ID: 10534 Checking the units at a data channel A power unit could be defined at the data channel even though the unit refers to operating values that are always converted to energy/work. This caused errors in the balances. Defining a power unit is now avoided. Processing number: 2015-000688 ID: 10204

24

ZFA-F device drivers gas 24/16.1 Kamstrup: Unigas 300 Selected DEVICEID_ADRESS is being ignored Instead of using the register ID from the configuration setting for reading the device ID, "0.0.0" was used. This caused the plausibility check "PP1" to fail. Processing number: 2015-000947 ID: 10847 24/7.2 Tritschler: K902/VC2 If scrap data are supplied, the VC2 does not stop importing At the evaluation of load profile data of a VC2 it could happen that a record including binary characters was tried to read. This lead to a closed loop of error messages. Processing number: 2015-001021 ID: 10933 ZFA-F device drivers different energy types. types of energy 23/16.1 Wackenhut: IMOD24NV IMOD24 readings do not work The reading failed if the meter supplied control characters before the device time. ID: 10451 24/16.1 Kamstrup: Unigas 300 Storing of load profile values with time stamp in standard time Now load profiles of Unigas300 devices that are always running in standard time can be imported. ID: 10127 28/2.1 Dr. Neuhaus gMUC Reading a MODBUS device on gmuc does not work Up to now it was not possible to read billing data of MODBUS devices that were connected to gMUC. Furthermore, it was not possible to rad devices by the manufacturer Carlo Gavazzi (GAV). In order to move the error completely it is required to use a gMUC firmware version from DNT8213-GMUC-4.55-851 or more recent. Processing number: 2015-000830 ID: 10942

25

Extensions/ new features/ changes in version 10.18 (Released on: 23/07/2015) Extensions/ new features/ changes New modules 22/12.14 ELGAMA: GAMA 100 G1B (DLMS) Device driver ELGAMA: GAMA 100 G1B (DLMS) New device driver ELGAMA: GAMA 100 G1B is released. ID: 7285 22/23.1 Holley: DDSD285 (DLMS) Device driver Holley: DDSD285 (DLMS) New device driver Holley: DDSD285 (DLMS) is released. ID: 8531 22/7.10 Itron: EM214 type 900 (IEC1107) Device driver Itron: EM214 type 900 (IEC1107) New device driver Itron: EM214 type 900 (IEC1107) is released. ID: 9119 Modified modules 21/26.2 EDIFACT/MSCONS interface edi@energy export Support of MSCONS version 2.2e and corresponding APERAK, CONTRL and OBIS version Support of MSCONS version 2.2e. ID: 8979 22/21.1 SATEC: EM720/ EM720T - functionality 1 Register reading for the number of relevant load profile channels The number of parameterized load profile data channels is not specified by the number of existing data channels but by the number of configured data channels at the device driver EM720. A data channel is configured if there are sourced values. Processing number: 2015-000641 ID: 9865

26

22/3.12 IskraEMECO: ME382/MT382 (DLMS) ME382/MT382 (DLMS): Fraud event log - reading of all entries Fraud log is always read completely. ID: 9780 24/16.1 Kamstrup: Unigas 300 ZFA-F: Added reading of month archives Now, the day profiles and/or month profiles can also be read and saved as prevalues to the current record. ID: 7802 24/2.7 Elster: DL230 (IEC1107) ZFA-F: Adding possibility for selecting password lock Now, you can select the corresponding password lock at the DL230. Available are: administrator lock, customer lock and data reader lock. Customers that have created devices with a version older than 10.18 need an update script. It can be provided by our support team. Processing number: 2015-000506 ID: 9586 26/9.1 ABB: F2 The optional card "min/max" should be integrated at the meter F4 Now, the device driver F2 supports the reading of several optional cards. There is no reading available for two simultaneous installed data logger cards at the moment. ID: 8651 31/1 Master data wizard Master data wizard overwrites the installation date at the device The installation date is only set if the status "installed on" is inactive at the installation of a meter via the master data wizard. ID: 7773 40/x Interface for mobile meter reading (MES-F) Route sorting does not work It was not possible to execute the route sorting. Now, the radio routes are sorted according to the route. Processing number: 2014-001181 ID: 7218

27

47/24.2.7 Elster: DL230 (IEC1107) MES-F: Adding possibility for selecting password lock Now, you can select the corresponding password lock at the DL230. Available are: administrator lock, customer lock and data reader lock. Processing number: 2015-000506 ID: 9587 93/1 Standard interface for master data transfer ZFA-F Synchronization of data channels without OBIS ID code The OBIS ID code was mandatory necessary at the synchronization of a data channel via the master data import. This is no longer necessary. The synchronization of all data channels is executed if there is no OBIS ID code indicated. ID: 9066 Transformer change with history of constants: Add device options "link" and "move" Now, the options "link" and "move" can be used at the transformer change with history of constants. ID: 9668 96/0 Interface for collection of measuring data Function "GetResultValues": Identification of devices with UIDENT Now, the identification of the meter in the Web-service interface is possible with the unique ID too. ID: 9206 OxCx system basis General communication module 2 (added reading via meter modem) Now, a meter modem can be selected at the general communication module. ID: 4388 Extension communication profiles Now, you can rename the communication profiles. You can delete communication profiles which are assigned to communication modes as well. ID: 8548 INI file "isu01f13.ini" is overwritten with the ITF standard file The customer specific adaptions were overwritten at the installation of a new ZFA-F version because of the settings in the file "isu01f13.ini" were deprecated. Now, the file "isu01f13.ini" is up to date. Processing number: 2015-000309 ID: 8892

28

Updating components of the WAMP packet (Apache, PHP, MySQL) Components of the WAMP packet were updated. - Apache 2.4.12 with OpenSSL/1.0.1m - PHP 5.6 - MySQL 5.6.25 Processing number: 2015-000555 ID: 9661 Deleting the report "print16.rpt" The report "print16.rpt" was no longer used and was deleted. ID: 9540 Output the message "power recovery" as warning The category of the event log message "power recovery" was changed from "note" to "warning". Concerns the following device types: 382J, CX20009, CX25009, MUCC_NZR, INDIGOP, G3B, MUCC, SIMPLEXME, SYM2KM, 7EV, A1350, A1500, ALPHA, ARM500, AS1440V, AS220, AS3000, DC3, DC4V, DLM6, DMTZ, EM4T, EM4TII, GEM, GSM5I, LZQJXCV, LZXJV, MM30, MT830, MT851, PK4, PWBIMOD, PZXJV, SPARKLOG, TE851, UNIGAS300, ZMDV, VC3, VCC, ZXF, A3R, EM1020, MX382, SENTINEL, ZMDD, ZMDV, ZXF, ZXG, ZXQ, ZXF, MRG800, MRG905, MRG910, EMETRION, NXT4. ID: 8788 Delete project "ymodem" The files "ymodem.dll" and "ymodem.ini" were deleted from the installation. ID: 9271 Meter modem Görlitz: AMC 190 (G) Meter modem Görlitz: AMC 190 was added. The selection of the meter modem is required if several VDEW meters are connected to the AMC190 and meters are parameterized with an initial Baudrate of 300 Baud. ID: 8044

29

Errors fixed in this version Administration for increased data security 15/3 Protection from accidental editing/deletion Device with protection from accidental editing/deletion A deactivated device was active again, by mistake, if the protection from accidental editing/deletion was set. Processing number: 2015-000126 ID: 10082 Copying of protected devices in not protected device group The protection from accidental editing/deletion was removed only from one element if there were several protected elements copied into a not protected group. Processing number: 2014-001227 ID: 8685 Calculations 30/28 Generation of substitute values load profile from register values Help for substitute value generation "load profile from register values" must be extended. There was a note missing in the help concerning the fact that the substitution method "load profile from register values" cannot be used for data channels with the measurement modes "mean power"and "current values" Processing number: 2015-000177 ID: 9525 30/5.5 Plausibility check - check of load profiles to billing data Plausibility check - check of load profiles PP10 The PP10 sent error if the load profile channel was read first and then the billing data channel. If there was a manual recalculation of the same files the PP10 was without any errors. Processing number: 2015-000121 ID: 9027 OxCx system basis Crash of ZFA-F at creation of a time frame in the history of constants ZFA-F crashes at recalculation if the constant for a billing data channel was changed. The process will be skipped because of the recalculation is basically not necessary. Processing number: 2015-000464 ID: 9559

30

Transformer change leads to value overflow The consumption at time of change was calculated incorrectly at a change of constants with the measurement mode "counter value" in the data channel. Processing number: 2015-000558 ID: 9704 Error message in search dialog "wrong argument displayed" A sporadic error message occurs after the Windows security update KB3059317 in the search dialog:"wrong argument displayed". ID: 10124 Database structure Database update failed, if the ZFA-F is installed in a directory with space characters. Now, the database update works correctly even if the ZFA-F is installed in a directory with space characters. ID: 8332 Unique Indizes for MS SQL Server database does not work The Unique Indizes were not created correctly at creation of a new MS SQL Server database. The cause of that was an incorrect definition in the file "indms.sql:" the key word "unique" was missing. This correction is only applicable from V10.18 because a program modification was necessary in ZFA-F. This modification has no effect on existing databases. ID: 9238 Data transmission 16/1 Configurable ASCII import A group was always created in the root at the ASCII import The ASCII import always creates a group in the root. Now, the behaviour at creation of a group after importing in the customer view corresponds to the behaviour of the device view. Processing number: 2015-000095 ID: 9259 21/19.2 EDIFACT/MSCONS interface VDEW export MSCONS export does not work via dynamic group The MSCONS export was not possible with a dynamic group. Now, the export works correctly even if a dynamic group is selected. Processing number: 2015-000323 ID: 9674

31

OxCx system basis Deletion of the module 21/A1 Import module for DG20 Module "21/A1 Import module for DG20" was deleted. ID: 9347 Deletion of the module 80/1 Interface SAP (RIVA) ("BAG Import") Module "80/1 Interface SAP (RIVA)" was deleted. ID: 9602 iClient 60/x Internet module / iClient Problem with the function "search" if a MS SQL Server database is used. Now, searching in iClient works correctly if a MS SQL Server database is used. Processing number: 2015-000603 ID: 10020 Language version of the iClient incorrect translated. Not all FR texts in the "zfasheet.ini" (responsible for the display of ID code texts) were translated until version 10.16. The "zfasheet.ini" in the FR version is complete translated from version 10.17. Processing number: 2015-000289 ID: 8851 Customized extensions 88/2 Metering data import format 1 Import of billing data failed if the fields "Latent Tariff Name" and "Latend Tariff Activation" are filled with space characters. Billing data could not be imported. Now, space characters as time stamp in the fields "Latent Tariff Name" and "Latend Tariff Activation" are accepted. Processing number: 2015-000491 ID: 9695 Interfaces for MES-F 21/20.1 Standard interface for billing Crash of ZFA-F at the import / export of MES-F orders via SCS Crash of ZFA-F at the import / export of MES-F orders via SCS. Processing number: 2015-000624 ID: 9891

32

Incorrect HHU import The import file was saved in the OK archive if an error occurred at the import. Now, the import file is saved in the error archive if an error occurs at the import. Processing number: 2015-000379 ID: 9124 44/x HHU program MES-F Demo rights are not checked according to expiration Demo rights were not checked according to expiration. Now, the right is inactive if the right is expired. Processing number: 2015-000242 ID: 9209 44/x MES-F reading with defaults Assignment of the scanned meter number failed The bar code scanner for the device Motorola MC55A was not activated. Processing number: 2015-000580 ID: 10050 Assignment of the scanned meter number failed The barcode scanner for the device Motorola MC55A was activated. Processing number: 2015-000580 ID: 10051 SCS 29/0 Smart Communication Server (SCS) Two simultaneous master control centers at the SCS Detection of two master control centers was possible due to the using of several ZFA-F Appserver. Processing number: 2015-000118 ID: 8176 Cascaded readings cannot be canceled The communication for one device was canceled if you attempt to cancel the communication of two cascaded devices via the Web interface. The cancel command was not considered at the second device. Processing number: 2014-001271 ID: 6271

33

Master data transfer 93/1 Standard interface for master data transfer ZFA-F Master data transfer failed An error occurred if there was more data channels indicated at the import file of the master data import (incl. OBIS-ID codes) than actual available at the device. Now, redundant data channels in the import file are not considered. Processing number: 2015-000239 ID: 9018 Sorting by column "name according to master data transfer" The original sorting of the data may not be retained after the synchronization of additional data via the master data import. Processing number: 2015-000205 ID: 8638 System basis 29/0 Smart Communication Server (SCS) Device to device constellations does not work. Device to device constellations were not possible if they are using the same driver. ID: 3748 Uneven distribution of orders with Prefix The concurrency of the control center was optimized. ID: 7713 44/x HHU program MES-F Error at setting for "Standard actions at reading without defaults" Both settings ("within time frame" and "without time frame") could be selected at choosing of the standard actions at reading without defaults "set date/time". Now, only one option can be selected. Processing number: 2015-000278 ID: 8816 Incorrect Greek characters INI files with Greek character code were not converted correctly. Now, character sets with foreign-languages are converted correctly. Processing number: 2015-000588 ID: 9909

34

OxCx system basis Synchronization of the INI files The following INI files were not synchronized completely: quant.ini ttgt.ini vp96em.ini vp96xm.ini zduemod.ini zvei.ini Processing number: 2015-000562 ID: 9644 Work with the favorites of the ZFA-F causes problems and could cause a crash. ZFA-F could perhaps not be started if favorites entries were added to a database from several ZFA-F clients with the same user. ID: 9787 All provided fonts are removed at uninstalling the feature "Webportal" (e.g. Arial) The font "Arial" was delivered with the feature "Webportal" and the registration of the existing font was overwritten. Thus, the font was removed too at uninstalling the feature "Webportal". Now, the font is no longer delivered and a possibly existing wrong registration is corrected. Processing number: 2015-000616 ID: 6288 The file "gasxexp.ini" will not be parsed at the update to version 10.16 Up to now, the file "gasxexp.ini" was overwritten at a ZFA-F update. Now, the settings are transferred from the file of the installed version. Processing number: 2015-000403 ID: 9513 Subordinated device is always displayed with link symbol If a device was subordinated to another device in the tree structure, the subordinated device was always displayed with the link symbol. ID: 6927 Database for data transfer could not be cleared when using the module "Shared time series administration" Error messages occur at the utilization of the shared time series administration at deletion of data from the archive database. Now, deletion in the archive database works even if the module "shared time series administration" is used. Processing number: 2015-000064 ID: 8038 The command line switch /A=NO does not work The automatic could not be switched on or off with the parameter /A=YES/NO. ID: 3812

35

Missing link symbol Moving devices with the assignment to a superordinated device via the master data import caused an incorrect displaying in the ZFA-F user interface because of wrong database entries. Now, moving of special devices is no longer permitted. Processing number: 2015-000184 ID: 8529 Error message at data transfer The data transfer of master data from and to an ORACLE database failed, if there where values in the latitude or longitude of a device. ID: 9765 Error message: "Record was refreshed" A message appears at the attempt to activate or deactivate a macro: "Record was refreshed". The changing was discarded and the record could not be saved. ID: 9524 Field "Sort_Nr" is not filled correctly The sort number of a newly created data channel was not set to the correct value. Processing number: 2015-000565 ID: 9623 The field "description" remains empty in the dialog "copy profile data" - display field "data channel name" Now, the name of the data channels can be displayed optional in the dialog of copying data channels. Processing number: 2015-000661 ID: 10076 Filter setting cannot be saved In the protocol view the filter setting for the tree view could not be saved. Processing number: 2015-000429 ID: 9571 Function container import: Entries in the filter criteria are not considered. The selections "device type" and "device number" were not considered. Now, containers with the adjusted selections are filtered correctly. Processing number: 2015-000494 ID: 10027 Measuring data check: No result in the customer view Source channels of evaluations could not be found at the measuring data check. The performance optimization which caused an error was canceled for the customer view. Now, the source channels are found again. Processing number: 2015-000663 ID: 9936 Oracle error messages Constraint violations occur at update commands to the table ACTION_EXEC in automatic mode. Processing number: 2015-000389 ID: 9529

36

Log view very slowly When accessing the function "protocol view" the messages were loaded immediately. This can take a very long time. Now, the messages are only loaded if the tab sheet "messages" is displayed. Processing number: 2015-000139, 2015-000428 ID: 9258 Font cannot be saved The modification of the font for the axis labeling and the axis title were not saved. After display change the standard font was used again. Processing number: 2015-000625 ID: 9896 Script Editor cannot be started An error message occurs at the start if the script editor includes the file to be opened as a parameter (e.g. when opening from the ZFA-F) and the script editor did no longer work. Processing number: 2015-000511, 2015-000594, 2015-000608 ID: 9860 Repeating of failed action groups Failed actions which were started via the web service interface were started again at a one-time schedule. ID: 9112 Time frame cannot be deleted Changes at the time frame for the history of constants could not be saved. Processing number: 2015-000558 ID: 9703 Changes regarding the meter value status are not logged at the messages of the meter data history The logging of the status change or value change of 0C values can be deactivated in the options. (LOG_STATUS_CHANGE_FROM_C_TO_X, LOG_VALUE_CHANGE_FROM_0C_TO_X). ID: 9185

37

Webportal 62/X Web portal Tables overlap the chart in the export file Beginning of the table overlaps the chart. The PDF export was restructured. Now, all views are clear and without overlaps. Processing number: 2015-000294 ID: 8875 ZFA-F device drivers electricity 20/4.1 Landis + Gyr: EKM647 (SCTM) Reading of different constellations does not work if the ZVEI driver is connected. The reading of billing data failed at the action sequence "reading event log and reading billing data". ID: 9431 22/11.1 LEM: EM4T/EM4T+ "Switch performed at the wrong time" at the EM4T Switch of daylight saving/standard time at the EM4T was performed at the wrong time because of a power failure. Now, the power failure can be handled and the data can be stored. Processing number: 2013-001494 ID: 9572 22/17.1 PRI: SprintXP Missing load profile values at reading The corresponding block was read again or the complete reading was repeated if the reading is executed exact during the day change. Processing number: 2015-000490 ID: 9749 22/2.14 EMH: EM4TII (IEC1107) Option "with daylight saving/standard time switch" can be deleted on the EM4TII The option "with daylight saving/standard time switch" was deleted in the device dialog because the option had no effect and delivers all time stamps in UTC. Processing number: 2015-000672 ID: 9987

38

22/21.1 SATEC: EM720/ EM720T - functionality 1 Calculation of the number of days was incorrect in the load profile recorder of the EM720 Calculation of the number of days was incorrect in the load profile recorder of the EM720. New register ID codes were added to the EM720 which allow you to determine the current load profile blocks. Processing number: 2015-000614 ID: 9757 Error message "No data existing" after load profile reading at the EM720 No load profile data can be imported from a certain time at devices which were in operation for a longer time. The cause of that was the cancellation of the reading after the maximum registration number was reached. Processing number: 2015-000586 ID: 9978 Status was not created for the load profiles at a power failure just before the end of integration period No marking of the load profile gap with status "N" occurs if power failure messages were written without integration period value for this time at the EM720. ID: 10005 22/3.11 IskraEMECO: ME382/MT382 (DLMS)GPRS reading with protocol DLMS TCP-UDP/IP not possible Protocol field for reading with DLMS TCP-UDP/IP protocol adjusted. Processing number: 2015-000471 ID: 9546 22/6.2 SLB/Actaris: SL7000 Incorrect values at reading of the SL7000 because of a new Firmware version First value of the day was missing. Now, the first time stamp is treated correctly. Processing number: 2015-000662 ID: 9921

39

22/8.4 SyM² standard Incorrect time assignment at empty Supercap via season switch at the Sym² driver Load profile values were imported incorrectly for one hour if the Supercap at a SyM² failed during the daylight saving/standard time switch. Processing number: 2014-001221 ID: 9325 SyM² incorrect result container is created An invalid result container was created if "Read date/time" was the last action in the action group and the communication between communication module and basic module of the SyM² failed. This is why the first load profile channel was not post-processed by the automatic. ID: 9414 ZFA-F device drivers gas 24/7.11 Tritschler G954/TC2 (IEC 1170) Difference time device type Tritschler TC2 The ZFA-F system time for calculation of the difference between device time and system time was converted incorrectly into the device time zone at reading of date/time, if the ZFA-F time zone was adjusted to Europe/Berlin and the time zone of the device was adjusted to Europe/without daylight saving time. This problem only occurs at daylight saving time Processing number: 2015-000385 ID: 9547 ZFA-F device drivers different energy types 22/2.2 EMH: LZKJ/LZQJ (Variant 2) Storing of load profile values with time stamp in standard time Load profile channels could not be stored if a device was parameterized without season switch. Processing number: 2015-000643 ID: 9844 OxCx system basis Missing units at energy type 5 (cold) Only the units "K" "°C" "°F" were displayed at the energy type "Cold". Now, all units which are available at the energy type "Heat" are provided. Processing number: 2014-001167 ID: 7636

40

Extensions/ new features/ changes in version 10.17 (Released on: 30/04/2015) Extensions/ new features/ changes New modules 22/2.17 EMH: Device driver EMH: Added new device driver NXT4 (EMH) IEC1107 protocol. Processing number: 2014-001159 ID: 8286 24/18.1 Emerson: Modell 700 (Modbus) Device driver Emerson: Modell 700 (Modbus) Load profile reading functionality 2 Device driver was extended by the reading of load profile data. Processing number: 2012-001188 4871 New released resources OxCx system basis Release of the database "Informix version 12.10xC5" The database "Informix version 12.10xC5" is released. ID: 9106 Release of the database "Microsoft SQL Server 2014" The database "Microsoft SQL server 2014" is released. ID: 5553 Release of the database "Oracle 12c" The database "Oracle 12c" is released. ID: 5797

41

Modified modules 18/1 Macro for automatic grouping Device grouping MP6 check Device grouping by a customer specific script with using the ID codes is possible, if a MP6 check failed. Processing number: 2015-000074 ID: 8207 21/29.2 EDIFACT/MSCONS interface Edi@Energy Export MSCONS decimal positions at the medium "gas" The MSCONS export was extended by the standardization G 685 for the number of decimal positions. Now, you can set per export macro the exactness according to the standardization G 685. Processing number: 2014-000754 ID: 6227 22/1.14 Elster: AS3000/AS3500 (IEC1107) Request of date /time incorrect due to deviated date format Date format "yy-mm-dd, HH:MM:SS" added under the ID 0.9.2. Processing number: 2015-000120 ID: 8527 22/1.8 Elster: Alpha / AS1440 Communication module AM100: Read configuration file and send to the modem. Extension of the communication module AM100 by the configuration upload and configuration download with SMP firmware update protocol. - Utilization of the already existing action "Firmware download" for the transmission of a new configuration. Differentiation if firmware file or configuration file by using file name extension. - Utilization of the already existing action "Read firmware name" for reading the configuration. Saving the configuration as file <device number>_<time stamp>.cfg. ID: 8008 22/3.12 IskraEMECO: Extension device driver (number of resets can be selected) Now, you can select the number of prevalue records to be read. Processing number: 2014-001342 ID: 7673 Extension device driver by the function "reading disconnect/connect log" The device driver was extended by reading event log "disconnect log". Processing number: 2014-001342 ID: 7870

42

Extension device driver by the function "reading fraud log" The device driver was extended by reading event log "fraud log". Processing number: 2014-001342 ID: 7674 23/16.1 Wackenhut: IMOD24NV Routing at Wackenhut IMOD Added routing functionality of the device driver. Now, you can define in the master data whether the modem is routed. ID: 7667 24/7.3 Tritschler: TTG (IEC1107) Reading prevalues at device driver Tritschler: TTG Data of both load profile channels are read at the request of billing data of a Tritschler TTG via the IEC1107 protocol. The prevalues of the maximum measuring values and the counter values from the load profile record are extracted at a change of months and are added to the billing data record. ID: 8420 29/9 IP telemetry switching center IptVcp must support the RoundRobin method according to IP telemetry. Now, the IptVcp supports the forwarding from one IP-T server to the other. This process is executed automatically as soon as the IP-T server refers to another IP-T server at a login attempt. ID: 8696 31/7 Administration of SIM cards Extend SIM card import by information "network region" and "communal utility service". The content of Ident1 and Ident2 is deleted by default via script. You can ignore deleting with the following parameters: /ClearIdent:false ID: 8554 47/28.6.2 GWF: FunkRMM-PI 4 (Wireless M-Bus EN 13757) Drive-by radio telegrams should send M-Bus status byte to ZFA-F (MESF-F) Now, the M-Bus status byte is transmitted to the ZFA-F at remote reading. Processing number: 2014-001143, 2014-001360 ID: 7136 Drive-by radio telegrams should send M-Bus status byte to ZFA-F (ZFAF-F) Now, the M-Bus status byte is transmitted to the ZFA-F at remote reading. Processing number: 2014-001143, 2014-001360 ID: 8812

43

81/8 Neutrasoft Diane Deletion of Module 81/8 Neutrasoft Diane Module "81/8 Neutrasoft Diane" was deleted. ID: 6694 OxCx system basis Revision of the unused entries in the table "CONFIG_TAG" When starting the ZFA-F the content of the tables "CONFIG_DATA" and "CONFIG_TAG" is checked and corrected if necessary. For this reason the first start of ZFA-F can take longer. ID: 8549 BSISMGW driver events / notifications The SMGW can send spontaneous events to the admin system. Now, conversion of events is supported. ID: 7623 Installation: Integrate visual C++ redistributable packages for Visual Studio 2013 Visual C++ redistributable packages for Visual Studio 2013 are installed in combination with the ZFA-F. ID: 8917 Meter modem Baer: UniMod GSM-4 The meter modem "UniMod GSM-4" by Baer is supported. Processing number: 2015-000150 ID: 8460 Errors fixed in this version Automatisms 18/1 Macro for automatic grouping Performance problem at device grouping The load profile data where still inspected if a device grouping with the feature "devices with meter data" is executed and the option "load profile data (incl. balances) was not set. Processing number: 2015-000233 ID: 8703 OxCx system basis The process stopped if ZFA-F or ZFA-F AppServer were closed The process stopped, if the application was canceled during reading results were imported. The process must be closed via the task manager then. ID: 9075

44

Calculations 30/29 Automatic generation of substitute values of register values from register values ZFA-F crashed when selecting tab sheet "Generation of substitute values at a billing data channel The ZFA-F crashed at selection of the tab sheet "Generation of substitute values at a billing data channel" Now, it is checked whether already saved substitution methods are available for the current data channel, which are no more licensed. Processing number: 2015-000194 ID: 8830 30/5.10 Plausibility check according to G 685 standard Consistency check according to G 685 standard on error after value overflow. An error message was written if the manual counter values of a device are not increasing monotonous. The consistency check is not executed for these devices. Processing number: 2014-001219 ID: 8441 31/5 Macro for automatic generation of substitute values Macro execution takes very long Even if the selection of one more device groups was limited in the device view or customer view, the determination of load profile gaps for the generation of substitute values via macro lasted very long. The manual search of load profile gaps via the measuring data check at the search dialog lasted also very long. Now, load profile gaps are determined much faster by taking account of the data channels contained in the selection. Processing number: 2014-001238 ID: 7468 Data transmission 21/29.2 EDIFACT/MSCONS interface Edi@Energy Export Export of prevalues not possible without main ID codes. The export of prevalues was not possible if the main ID code did not exist. Processing number: 2015-000299 ID: 9032 Section "data" too large Some settings for the billing data export were displayed even if they were not used. ID: 7962

45

OxCx system basis Error codes are not logged at data access A sporadic error appears at the export of files, which were accessible via network directory. Searching for the cause was difficult, because no detailed error codes of the operating system was output. Now, the error codes of the operating system are output if errors occur at the handling of files (e.g. network failure) Processing number: 2015-000001 ID: 8807 Interfaces for MES-F 44/x MES-F reading with without defaults No total readout in the presettings of the device driver There is no total readout available in the presettings of the device driver. The action is already available at the actions of the VDEW meters (e.g. A1500) .The total readout was already preselected at the load profile reading of the device drivers. Now, you can select only one type of load profile at the preselection for load profile reading. ID: 8523 44/x MES-F Module for barcode reading The integration of the barcode scanner for the device "CipherLab CP60" is not complete. The barcode scanner for the device "CipherLap CP60" was not integrated complete. Processing number: 2014-001293 ID: 8695 SCS 29/0 Smart Communication Server (SCS) No message at missing right A log message is written if a right for a communication system (e.g. SCS) is inactive and the automatic processes a corresponding order. ID: 7331 29/9 IP telemetry switching center Reading of IEC1107 devices does not work Sometimes the reading could be executed not completely at reading of larger amount of data via IptVcp. Furthermore, the port was not initialized at the next readings. ID: 8710

46

Push target does not log on at the IP-T slave Due to the introduction of the communication profiles, a value was misinterpreted. Thus, the push targets cannot log on the IP-T slave. Processing number: 2015-000265 ID: 8811 System basis 18/14 Macro for automatic post-processing of gaps in load profiles Bad performance at the function "post-processing of load profile gaps" The performance of the macro function "post-processing of load profile gaps" was improved, if the selection was limited to one or several device groups in the device view or customer view. Processing number: 2015-000179 ID: 8750 40/x Interface for mobile meter reading (MES-F) No sorting of the routes overview The routes were not sorted according to names. Processing number: 2014-001330 ID: 7657 OxCx system basis The file "status.dat" is not refreshed The file "status.dat" was not refreshed at the execution of the device grouping. Processing number: 2015-000169 ID: 8603 Wrong ODBC name ("zfaprint") for the print database The old ODBC names "zfaprint" were used in some cases. The INI files are adjusted. Now, the correct ODBC name "zfa_f_print1", the DB user name "zfa_f_print1" and the default password is used. ID: 6394 Error in message view The severity "note" was not saved in the filter at the message view. A toolbar (refresh/cancel) was displayed twice on the message page of the device view. ID: 9044 Error message at data transfer The data transfer of master data from and to an ORACLE database failed, if there where values in the latitude or longitude of a device. Processing number: 2015-000227 ID: 8838

47

Rights to move a data channel link Moving a data channel link was only possible with the right "delete measuring data". Processing number: 2014-000462 ID: 6128 Selection in the tree structure You can directly select devices in the tree view by clicking the first letter on the keypad. But this does not work with the keys "C", "X" and "V". The element was copied into the clipboard with "C" , cut out with "X" and added with "V" as like the keystroke combinations "Ctrl-C", "Ctrl-X", "Ctrl-V". The behavior was corrected. Now, the devices can be selected with the keys "C", "X" and "V" in the tree view. Processing number: 2014-001001 ID: 6635 Sporadically freeze of the application in conjunction with the Informix version 12.10xC4 The application server freezes if you are using the Informix database. Install the Informix version12.10xC5 to solve the problem. Processing number: 2014-000500, 2015-000083 ID: 5675 ZFA-F device drivers electricity 22/1.3 ABB: ALPHA/A1500 Date format was misinterpreted The date format was misinterpreted at the A1500. Processing number: 2015-000061 ID: 8509 22/12.5 ELGAMA: EPQS (IEC1142) Time synchronization The time cannot be set in the meter if an EPQS was parametrized with a DES key shorter than 8 characters. ID: 8544 22/18.1 Schneider: ION 8600 Unable to read meter after Jordanian time switch It was not possible to read the load profiles of an ION device at the switching day of standard time to daylight saving time. This problem only occurred at country settings with switching at 00:00 o'clock Reason for this problem was the reading at 00:00 o'clock on the switching day. The time stamp 00:00 o'clock is considered to be invalid because the switch should be carried out at that time. Processing number: 2015-000321 ID: 8951

48

22/21.1 SATEC: EM720/ EM720T - functionality 1 Different time stamp format at historical billing data records At the EM720 you have the possibility to separate actual values from the reset values at creation of a billing data record. But the time stamps were displayed in another format than in the actual billing data record at creation of a reset data record. Processing number: 2015-000258 ID: 8767 ZFA-F device drivers gas 24/2.4 Elster: EK260 Missing device messages EK260 Sometimes the EK260 supplied the message "unknown message" while importing the event log. The messages of the EK260 were extended and matched to the current description. Processing number: 2015-000181 ID: 8594 24/7.2 Tritschler: K902/VC2 The message "incorrect protocol flow" is carried out at the time synchronization. If a VC2, VC3 or VCC supports only one time synchronization, no error message occurs in the future, if the meter set the time only shortened. Processing number: 2015-000078 ID: 8640 24/7.3 Tritschler: TTG: Reading of date/time does not work It could happen, that checksum errors occur at the reading of the TTG time, due the fast reading and overlapping of data. ID: 8895 24/9.2 RMG: EC 994 Incorrect intermediate value is imported Under certain conditions, an intermediate value delivered by the meter was stored as final load profile value. Processing number: 2015-000248 ID: 8889 24/9.4 RMG: ERZ 2000 Prevalues could not be read It could happen that only the normal billing data were displayed and the prevalues were deleted at the conversion of billing data with prevalues via DSfG device driver. Processing number: 2015-000272 ID: 8836

49

OxCx system basis Logging causes a delay at sending The logging of large amounts of data causes a delay of sending the data. This could lead to connection clearing of the device. Now, you can limit the logging and representation of the sent data. ID: 8894 ZFA-F device drivers different energy types of energy 28/10.1 MUC standard Incorrect import because of the push data are also stored in inactive data channels. The MUC sensor stores data of inactive data channels, due to this an error message was output. Processing number: 2015-000366 ID: 9116 Extension of messages if there is no ID code Now, an error message is output if the selected OBIS ID code is missing in the load profile data of the MUC. Processing number: 2014-001287 ID: 7661 Device driver MUC: Operating values are imported incorrectly at daylight saving time/standard time switching day. If the MUC supplied the first load profile value in the second switching hour on the daylight saving time/standard time switching day at push operation, this value was included in the first hour. Now, the operating value is imported correctly in the second hour. ID: 9186 ZFA-F device drivers heat/cold 26/9.1 ABB: F2 Load profile reading via the driver F2 does not work correctly at a F4 meter It was possible, that the reading was executed correctly but no load profile data were stored at the device driver for the F2. The reason was the reading from the complete memory, this could be include unvalid time frames. Processing number: 2015-000225 ID: 8701

50

Extensions/ new features/ changes in version 10.16 (Released on: 10/03/2015) Extensions/ new features/ changes New modules 18/15 Macro for SFTP /FTP transfer Extension of the FTP macro by SFTP The new macro function "SFTP/FTP transfer" can be used to transfer files between the local file system and the server via FTP or SFTP. Following actions are available: - Upload - Download - Upload & Delete - Download & Delete - Delete ID: 3733 22/19.1 Sagemcom: CX2500-9 (DLMS) Release device driver Sagemcom: CX2500-9 (DLMS) functionality 1 Module 22/19.1 Sagemcom: CX2500-9 (DLMS) is released. ID: 5233 22/19.2 Sagemcom: CX3500 (DLMS) Release of device driver Sagemcom: CX3500 (DLMS) functionality 1 Module 22/19.2 Sagemcom: CX3500 (DLMS) is released. ID: 4446 22/19.8 Sagemcom: CX2000-9 ( DLMS) Release of device driver Sagemcom: CX2000-9 (DLMS) Module 22/19.8 Sagemcom: CX2000-9 (DLMS) is released. ID: 7899

51

Modified modules 18/0 Macro control Remove limit regarding the number of characters in column "Conditions" Up to now a maximum of 80 characters could be entered in column "Conditions". A database error message appeared if you tried to enter more characters. The limit regarding the number of characters does not exist any longer. You can enter a condition using as many characters as desired and save it. Processing number: 2012-000631 ID: 186 22/8.4 SyM2 standard Save message for exceeding the time drift at device The error message which is output if the maximum value is exceeded is now saved to the device. Processing number: 2015-000009 ID: 8000 62/X Web portal Overview page for starting web products An overview page for starting the web products "iClient", "Webportal" and "SCS" has been created. ID: 4302 88/2 Metering data import format 1 Consideration of history of constants when importing values The measuring data import also considers the constants set in the data channel. Processing number: 2014-001348 ID: 8014 OxCx system basis Set "Date/time" with ZVEI driver (ZFA-F / MES-F) The ID code 0.9.129 for setting the "Date/time" was added. Processing number: 2014-001244 ID: 8324

52

Processing of communication profiles in all components Now a communication profile can be selected for each communication mode at the communication system SCS. There you can define special communication settings for each device driver independent from the general settings. ID: 7249 Reduction of message entries The meter data history only logs the number of changes (value, status, tariff) per data channel as well as the time frame of the first and the last change but not every single change. You can restore the old behavior in the centrals configuration (General/Meter data history/LOG_FILE_LEVEL = MEASURED_VALUE). ID: 949 Errors fixed in this version Automatisms 18/14 Macro for automatic post-processing of gaps in load profiles The automatic post-processing of gaps does not group devices correctly if the gaps are one day The automatic post-processing of load profile gaps did not detect gaps that were exactly one day long. ID: 7128 Calculations 30/16 Generation of substitute values by direct comparison Tariff services are not transferred correctly (direct comparison) The service "T2" was not displayed in the reference channel in the dialog "Substitute Value Wizard" of the comparative method. Processing number: 2014-001366 ID: 7961 30/26 Generation of substitute values load profile from register values Incorrect value calculation No resp. incorrect substitute values are created at data channels with assigned tariff structure and complete day gaps. Now, the corresponding tariffs are created prior to the determination at data channels with assigned tariff structure and complete day gaps. The created substitute values are correct now. Processing number: 2015-000090 ID: 8623 30/28 Generation of substitute values load profile from register values

53

Transformer constants are not considered at generating substitute values (load profile from register values) If the substitute method „Load profile from register values" was executed, the transformer constants were not considered. ID: 6981 31/5 Macro for automatic generation of substitute values Macro execution takes very long Even if the selection of one or more device groups was limited in the device view or customer view, the determination of load profile gaps for the generation of substitute values via macro lasted very long. The manual search of load profile gaps via the measuring data check at the search dialog lasted also very long. Now, load profile gaps are determined much faster by taking account of the data channels contained in the selection. Processing number: 2014-001238 ID: 7468 Data transmission 16/1 Configurable ASCII import Search does not work with special characters (for example "[") Now, assignments in the ASCII import operate under SQL server even if an opening square bracket is included. ("["). Processing number: 2015-000148 ID: 8599 21/29.1 EDIFACT/MSCONS interface Edi@Energy import Missing logging at macro function "MSCONS import" At the MSCONS import the messages were displayed at the macro function instead at the import function. Now, all import messages are displayed at the import. Processing number: 2014-000507 ID: 5701 21/29.2 EDIFACT/MSCONS interface Edi@Energy Export Time stamp is set incorrectly at state-controlled MSCONS export Time stamp "to" was set incorrectly at event-driven data channels at state-controlled MSCONS export. Processing number: 2015-000063 ID: 8333

54

80/11 Standard interface for SAP IS-U High run time and incorrect link at SAP import There was a long run time if you tried a data channel assignment with a unfilled ident field. Now, the assignment is canceled if a second record is found, because the data channel must be unique. Processing number: 2015-000044 ID: 8564 iClient 60/x Internet module / iClient Spontaneous reading is unusable at long reading times Depending on the reading type or reading time frame, the spontaneous reading could take very long. During this time a load symbol appears and the application could not be operated. Timeouts occurred frequently The spontaneous reading was optimized to avoid long reading times. When clicking "Start" a message appears, that the reading was started. All started readings are displayed in the menu overview "current reading" ID: 6119 Customized interfaces 88/2 Metering data import format 1 Values do not match the ID codes when importing billing data The OBIS-ID codes 96.50.11, 96.50.12, 96.50.13, 96.50.14, 96.50.10 were included in the billing data record, but the values do not match the ID codes. The reason was that the values of the named OBIS-ID codes are changed from a post processing script after remote reading at import. The values of the OBIS-ID codes 96.50.11, 96.50.12, 96.50.13, 96.50.14 and 96.50.10 are converted into a readable text. Processing number: 2014-001348 ID: 7833 Interfaces for MES-F 40/x Interface for mobile meter reading (MES-F) Missing settings at manual reading A selection of devices was not possible if the right "removal orders without order" was not available on the handheld unit. The function call of the device list is now possible again Processing number: 2014-001315, 2014-001328, 2015-000018 ID: 8076

55

Wait dialog is not displayed The interface had been frozen if the MES-F actions were longer. This creates the feeling of a crash. Now, a wait dialog appears if the MES-F cannot be operated because data are processed in the background. Processing number: 2014-001267 ID: 7651 44/x HHU program MES-F MDG import does not work at reading a DC3 meter with 3 load profiles Further data channels were ignored if the billing data channel was imported after the first load profile channel. Now, the first load profile channel is known and further load profile channels can be imported. ID: 8601 44/x MES-F reading with without defaults Displayed text incorrect Orthography has been corrected: "the last month" ID: 8424 System basis 22/1.11 Elster: Alpha / AS220 - functionality 2 The right for the device action "Switch on" is missing in the license administration The right 975 for the device action "Switch on" was missing in the license administration for the following devices: AS220, AS1440, Enerscape meter and MK7C. Processing number: 2015-000028 ID: 7930 OxCx system basis Subordinated device is always displayed with link symbol If a device was subordinated to another device in the tree structure, the subordinated device was always displayed with the link symbol. ID: 6927 Device drivers are missing in the "COMSTAT" script There were some device drivers missing in the script “COMSTAT”. The script export was extended in order to determine the protocol of a meter via the command "Get("Store_Device", "Protocol")". The script "COMSTAT.SCT" was adjusted correspondingly for the communication statistic. Due to this no protocols are written to the statistic at some device types. ID: 7728

56

Meter data maintenance of values with status "E" If the meter data maintenance "Recalculate operating values" with the setting "Delete edited values" was executed for a load profile channel after a modification of data (e.g. by Generating substitute values), an incorrect accumulated value was displayed. The correct value was displayed only after a second execution of the meter data maintenance. Now, the correct accumulated value is already displayed after the first execution. Processing number: 2014-001317 ID: 7603 Callback order is not saved It was not possible to save the callback order at communication parameters/COM port under management/options of the COM-F application. Processing number: 2014-001043 ID: 6747 Search does not work with special characters The standard search of the Microsoft SQL server does not work if angular brackets was included in the search term. Processing number: 2015-000013 ID: 8033 ZFA-F crash ZFA-F crashed if the sorting of the MES-F orders was changed. ID: 8413 Time series administration 95/Ox Shared time series database Shared time series database (e-count) in combination with ID management of high IDs via Stored Procedure (sequences) The shared time series database (e-count) does not work with the ID management of high IDs via Stored Procedure (sequences). Now, the import of load profile data works with high IDs. Processing number: 2015-000059 ID: 8206 ZFA-F device drivers electricity 22/1.3 ABB: ALPHA/A1500 Crash of COM-F application It may be possible that the COM-F crashes at the night meter reading since the last update to version 10.15. The exit from the programming mode was improved to solve this problem. Processing number: 2015-000122 ID: 8312

57

Date format was misinterpreted The date format was misinterpreted at the A1500. Processing number: 2015-000061 ID: 8509 22/1.8 Elster: Alpha / AS1440 Reading of cascaded devices does not work Cascaded devices of the type "AM100+MBUS" cannot be read with only one call. Processing number: 2014-001301 ID: 7743 22/11.1 LEM: EM4T/EM4T+ Missing description of the entry "POWER_FAILURE_STATE_N=NO" in the help. The description of the entry "POWER_FAILURE_STATE_N=NO" was missing in the help. Processing number: 2014-001101 ID: 6860 22/12.5 ELGAMA: EPQS (IEC1142) Exception at import Result container from incorrect readings caused a crash of ZFA-F. Processing number: 2015-000192 ID: 8545 Time synchronization The time cannot be set in the meter if an EPQS was parametrized with a DES-key shorter than 8 characters. The DES-encoding was matched according to the specification of Elgama. Processing number: 2015-000050 ID: 8544 22/18.1 Schneider: ION 8600 Deviations at setting "Date/time" ION7500, ION8600 and ION8800 were set in the future for several seconds at setting "Date/time". Processing number: 2014-001346 ID: 7772 22/21.1 SATEC: EM720/ EM720T - functionality 1 Incorrect time at reading of an EM720 with switch The additional hour was charged twice to the displayed time, if the time was delivered in daylight saving time of a EM720. The evaluation for the time to be displayed was adjusted. Processing number: 2014-000792 ID: 6735

58

22/3.12 IskraEMECO: ME382/MT382 (DLMS) ID codes 96.11.x are not read correctly Incorrect interpretation of the ID codes 96.11.0 96.11.1 and 96.11.2. Now, they are interpreted as text. Processing number: 2015-000051 ID: 8034 22/5.4 Siemens/Landis & Gyr: ZMD/ZFD (VDEW) Message "The measured value is not onside of the integration period raster" at ZMD/ZFD VDEW If the requested time frame includes integration periods in which the time was set back over one integration period, and the latest value was outside of the requested time frame, the message "The measured value is not inside of the integration period" was displayed. So, the data were not imported. Processing number: 2014-001361 ID: 7776 22/8.4 SyM2 standard Data gaps at push mode SyM² Data gaps occurred at meters operated in push mode. This is why the timeout for incomplete push data records was set from 1 minute to 30 minutes. Processing number: 2013-000868 ID: 2857 ZFA-F device drivers gas 24/16.1 Kamstrup: Unigas 300 Negative values cannot be imported The conversion was canceled by the driver if a Unigas 300 supplied negative values in its load profile values. The special driver was adjusted and negative values can be imported, now. Processing number: 2015-000023 ID: 7975 24/7.2 Tritschler: K902/VC2 Status "I" at interference channels of VC2 devices It was possible, that the status "I" (temporary) was set at reading of VC2 interference channels. This behavior was changed. Now, the stored values are no longer marked with status "I" at event-driven channels. Processing number: 2015-000076 ID: 8103

59

ZFA-F device drivers different energy types. IMOD24NV Switch Wackenhut IMOD At the reading of cascaded meters via the meter modem "IMOD24" it was possible that the switch from one to the other meter was not executed. As a consequence the wrong data were written in the container at the request of the second meter. Now, the switch is verified and is repeated in case of an error. ID: 8084 WTT16 Reading of network nodes on a WTT16 at M-Bus devices failed. Certain M-Bus devices could not be read after the communication mode of the COM-F to the WTT16 was set from "Power line" to "Leased line" (TCP/IP). Now, network nodes can be read. (Plain Text VIFs: ID "% BATT") Processing number: 2014-000850 ID: 8138 OxCx system basis Missing units at energy type 5 (cold) Only the units "K" "°C" "°F" were displayed at the energy type "Cold". Now all units which are available at the energy type "Heat" are provided. Processing number: 2014-001167 ID: 7636 ZFA-F device drivers heat/cold 26/9.1 ABB: F2 No result is written in the container in case of incorrect data. Status code or data were entered in the result container if a M-Bus device returned non-plausible values. The problem has been solved for all M-Bus devices in the basic driver. in case of incorrect data, the message "Incorrect protocol flow" is output now. Processing number: 2014-001369 ID: 7944

60

Extensions/ new features/ changes in version 10.15 (Released on: 23/12/2014) Extensions/ new features/ changes New modules 22/1.14 Elster: AS3000/AS3500 (IEC1107) Release device driver "AS3000/AS3500 (IEC1107) Functionality 1" Module 22/1.14 Elster: AS3000/AS3500 (IEC1107) Functionality 1 is released. ID: 4774 22/1.15 Elster: AS3000/AS3500 (IEC1107) Release device driver "AS3000/AS3500 (IEC1107) Functionality 2" Module 22/1.15 Elster: AS3000/AS3500 (IEC1107) Functionality 2 is released. ID: 6383 28/6.3 OMS standard (Wireless M-Bus EN 13757) Device driver OMS with functionality 2 (MES-F) Module 28/6.3 OMS standard (wireless M-Bus EN 13757) is released. In the course of this, the database was extended by the field "Private key". If a private key is required for a device reading, a database from version 10.15 has to be used. ID: 1496 Device driver OMS with functionality 2 (ZFA-F) Module 28/6.3 OMS standard (wireless M-Bus EN 13757) is released. ID: 6760 46/22.3.10 IskraEMECO: MT880 (DLMS) Release of MES-F device driver "IskraEMECO: MT880 (DLMS)" Module 46/22.3.10 IskraEMECO: MT880 (DLMS) is released. ID: 5555 47/24.2.7 Elster: DL230 (IEC1107) Release of device driver "Elster: DL230 (IEC1107)" Module 47/24.2.7 Elster: DL230 (IEC1107) is released. ID: 6047

61

New released resources OxCx system basis Release CINTERION BGS2 terminal The GSM central system modem "CINTERION BGS2 terminal" is released. ID: 6612 Modified modules 21/26.2 EDIFACT/MSCONS interface Edi@Energy Export Filling segment "RFF+MG" with user-defined field The device number was used as meter number at the export of billing data in segment "RFF". Now you can configure per macro where the meter number is saved. ID: 6755 Support of MSCONS version 2.2d and corresponding APERAK, CONTRL and OBIS version Support of MSCONS version 2.2d. Restriction: Gas property data are exported according to the old MSCONS standard. ID: 6824 Support of document type "Gas property data" in MSCONS version 2.2d At the MSCONS export, the calorific value, operating consistence, standard density and all gas parts (Nitrogen, Hydrogen etc.) are exported with the identification "Z21" (BGM segment) and the validation indicator "13007" (RFF segment). ID: 6978 22/1.8 Elster: Alpha / AS1440 Reading event logs Bit 16 - 31 of the AS1440 Added extended event log messages. Processing number: 2014-001069 ID: 6834 22/5.6 Siemens/Landis & Gyr: ZMQ/ZFQ (DLMS) Device driver Landis+Gyr: ZMQ/ZFQ (DLMS) - Support of meters without daylight saving/standard time switch Installed request from meter whether daylight saving/standard time switch is executed. The time stamps are interpreted according to this setting. Processing number: 2014-001194 ID: 7199

62

23/2.4 Görlitz: ENERCOM400(E/G) - functionality 2 Enercom 400 TSS11 signal input "switching process" as device message Spontaneous messages of the TSS11 message input are saved as device message. ID: 6765 28/6.3 OMS standard (Wireless M-Bus EN 13757) Master data transfer with KEM file of Kamstrup The private key for Multical21 devices can be read from the KEM file of Kamstrup and assigned correspondingly by means of the master data transfer. ID: 7294 Incorrect device name "Radio module OMS (GWF)" So far “GWF” was indicated as manufacturer of the “Radio module OMS". The manufacturer was removed from the name since the “Radio module OMS" stands for several devices of different manufacturers. The database has to be adjusted by means of the corresponding SQL script in order to apply the changes to the tree structure in the device view. ID: 7456 29/0 Smart Communication Server (SCS) Push data must remain Now push results are read, deleted and imported one after the other by the SCS control center and not as package. Thus, results cannot be lost if the ZFA-F Appserver is cancelled or crashes during the import process. Processing number: 2014-000571 ID: 5838 30/5.10 Plausibility check according to G 685 Field "rel. deviation" always has to be filled The field "rel. deviation" is always filled, now. Processing number: 2014-000986, 2014-000508 ID: 6666 46/22.1.8 Elster: Alpha/AS1440 (IEC1107) DB update script with device actions "Disconnect", "Connect" and "Switch on" of AS1440 A script for adding the device actions "Disconnect", "Connect" and "Switch on" for the device driver AS1440 was created. Processing number: 2014-001149 ID: 7629

63

Adding functionalities "Disconnect", "Connect" and "Switch on" of the meter on-site (MES-F) The device driver AS1440 was extended by the functionalities "Disconnect", "Connect" and "Switch on" of the meter on-site. Processing number: 2014-001149 ID: 6993 Adding functionalities "Disconnect", "Connect" and "Switch on" of the meter on-site (ZFA-F) The device driver AS1440 was extended by the functionalities "Disconnect", "Connect" and "Switch on" of the meter on-site. Processing number: 2014-001149 ID: 7622 62/X Web portal Interface can be matched according to the Corporate Identity You can adjust the interface according to the Corporate Identity via the file ci_config.php. The folder "default" contains the standard configuration. So far the configuration is not synchronized at an update. ID: 5804 93/1 Standard interface for master data transfer ZFA-F Time default for meter installation Now the installation date can be adjusted to the integration period at the meter installation. Processing number: 2014-000886 ID: 6597 97/2 Standard Web service interface Interface for search function at iClient Implementation of an internal web service interface for an efficient search function at the iClient. Processing number: 2014-001152 ID: 6872 OxCx system basis Apply new rights to all users at importing the license New rights and limits can be applied to all users if the license is imported In this case a message window appears during the update process asking whether you want to apply the new rights and limits to all users. ID: 373

64

Add new modem "BGS2 Terminal" to COM-F and SCS The central system modem "BGS2 Terminal" is released. ID: 6924 Extension of password field at modem The maximum length for passwords of communication modules is now 20 characters. ID: 6877 Errors fixed in this version Automatisms 18/1 Macro for automatic grouping Incorrect device grouping if module "Plausibility check" is missing The dependency of the function "Device grouping" on the function "Plausibility check" was not represented correctly at the license administration. Now, the required right for the plausibility check is activated if the device grouping is activated. Processing number: 2014-000759 ID: 6921 18/14 Macro for automatic post-processing of gaps in load profiles A sporadic gap appears in the integration period at the post-processing of data gaps. It could happen that the last integration period value of the meter was not post-processed at the post-processing of data gaps. The time frame was extended by one integration period. ID: 6868 Inactive devices are considered at the post-processing of load profile gaps Inactive devices were not grouped at the automatic post-processing of gaps, however, the time frame for the post-processing was saved to the active data channel. Now the post-processing time frame is not entered at inactive devices. Channels of interference are not considered as well. ID: 6917 Calculations 21/19.2 EDIFACT/MSCONS interface VDEW export Too many assert messages are written to the event log if the metering point names are too long at the MSCONS export Error messages were output if a metering point name consisted of more than 35 characters. Now only the error message that the metering point has not been exported is output. Processing number: 2014-001078 ID: 6969 30/10 Organization of virtual billing records

65

Entries cannot be saved Entries cannot be saved under the tab sheet "Data channel". An entry that was made disappeared from the field if you tried to save it. Processing number: 2014-001261 ID: 7699 30/26 Generation of substitute values load profile from register values Automatic substitution methods with single modules 30/25, 30/26 and 30/29 not available If only the substitution modules 30/25, 30/26 or 30/29 were active, the corresponding automatic substitution methods were not available. Now, the substitution methods are also available even if only one of the modules 30/25, 30/26 or 30/29 " is active. ID: 6968 30/28 Generation of substitute values load profile from register values Manual generation of substitute values “Load profile from register values" calculated negative substitute values The generation of substitute values calculated incorrect values if the time zone "Europe/Berlin" under the ZFA-F option "Time zone administration" was not selected. Now the generation of substitute values works correctly even if another time zone is selected under "Time zone administration". Processing number: 2014-001020 ID: 7566 Manual generation of substitute values at daylight saving/standard time switch If the substitute method "Load profile from register values" was executed during the daylight saving/standard time switch, the message "No data existing" was output if settings were transferred. Now, corresponding measuring value statuses are added at the season switch. Processing number: 2014-001259 ID: 7539 30/3 Time related calculations "Suppress status C" does not work at event-driven channels of disturbance The option "Suppress status C" did not work if event-driven data channels were assigned as source to a load profile calculation and if there were no profile data in the corresponding time frame. Processing number: 2013-001078 ID: 6869 30/5.10 Plausibility check according to G 685 30/5.10 Plausibility check according to G 685 If the device ID remained empty, only the master data of the first device were included in the calculation of several devices (multiple processing). All results were written one below the other and could not be assigned to a device. Processing number: 2014-001226 ID: 7374

66

30/5.6 Plausibility check for master data check Synchronization of device ID at PP1 fails due to space character A master data error was output at the execution of PP1 because existing space characters in the device ID were not cut off at the synchronization. Now the space characters are removed before the synchronization is executed. Processing number: 2014-001260 ID: 7645 Database interfaces 21/10 Data transfer via laptop Import to Microsoft SQL database not possible The data transfer was cancelled at the export to a Microsoft SQL Server database if the data to be transferred contained an exponent. Now the data transfer can deal with all variants of a floating point number. Processing number: 2014-000997 ID: 7040 Data transmission 21/19.1 EDIFACT/MSCONS interface VDEW import Missing note in help A note was missing describing that the option "Cancel at temporary values" at the MSCONS export only works if the state control is activated. Processing number: 2014-000360 ID: 5389 21/26.2 EDIFACT/MSCONS interface Edi@Energy Export Description of new MSCONS version 2.2d and the document type "gas property data" The description of the new MSCONS version 2.2d and the document type "gas property data" was missing. The help "if_msc1.chm" was extended by the description of the MSCONS version 2.2d and the document type "gas property values". ID: 7494 ZFA-F crashes at executing a help link The help for the MSCONS export included a link to a PDF file of an external website. That link caused a crash of ZFA-F. The link to the PDF file was removed. Now the link only refers to the corresponding website (www.edi-energy.de). ID: 7553

67

21/29.2 EDIFACT/MSCONS interface Edi@Energy Export ZFA-F crashes at MSCONS export of billing data ZFA-F crashed at the export of billing data if the version "Default" was selected. Processing number: 2014-001241 ID: 7357 30/5.10 Plausibility check according to G 685 Time difference of 1 hour at macro "G685" There was a time difference of one hour at the calculation of the lower and upper limit of the macro function "G685". Processing number: 2014-001226 ID: 7590 81/10.1 Interface IS/E XML format Export of two billing data channels under one meter The export script "ise_xml.sct" only exported data of one billing data channel even if there were two channels assigned to the meter. Processing number: 2014-001310 ID: 7656 Interfaces for MES-F 21/20.1 Standard interface for billing Incorrect record saved to form at change orders It could happen that the data record read previously was not deleted if a reset was executed. Processing number: 2014-001189 ID: 7194 44/x HHU program MES-F MES-F logging with incomplete time stamp The MES-F log file was created incorrectly. Now milliseconds are formatted correctly at the time stamp. ID: 7106 Billing data are not assigned (HHU import format 2) The device ID remained unchanged if a device ID was transferred from the billing data record. Now leading zeros can be removed if required. Processing number: 2014-001147 ID: 7302

68

47/28.6.2 GWF: FunkRMM-PI 4 (Wireless M-Bus EN 13757) Crash at radio reading A memory exception occurred at a radio reading if the device drivers were loaded. Processing number: 2014-001089 ID: 6905 SCS 29/0 Smart Communication Server (SCS) The control center loses IP-T slave statuses if the network is disconnected The control center lost IP-T slave statuses if the network was disconnected. Now the statuses are requested by the IP-T master again. Processing number: 2014-000985 ID: 7316 The base.dll does not work under Windows Server 2003 The base.dll could not be loaded if the operating system Windows Server 2003 was used. ID: 7095 Error at saving the deactivation mode If a new deactivation mode was created an error message occurred at saving the deactivation mode and the process failed. Processing number: 2014-001136 ID: 6982 Error on web interface: Field "Source" too small The combo box for indicating the sources in the communications log had a fixed width of 100 characters. Entries that were longer could not be displayed completely. Now the combo box is created with a dynamic width which corresponds to the length of the entries. Processing number: 2014-001156 ID: 7196 Incorrect filtering in the communications log overview There was no filter set for the communications service or for the device ID if the communications log view was opened via the log link (in column "Action") in the order list. Thus, all communication messages were displayed. Now the communications service or the device ID is transferred to the log view and considered at the filter process. Processing number: 2014-000987 ID: 6658 Device driver "CALEC" is missing in the settings/DEVICES of the SCS web interface The communication settings for the CALEC MB were added to the SCS. Processing number: 2014-001262 ID: 7454

69

No online times at multiple connections via SCS The online time was not determined correctly at cascaded, IP-based requests. Processing number: 2014-001126 ID: 7087 Timeout setting at inactivity not considered No message was output if the session timeout was exceeded and the user was not guided to the login page via a link. ID: 5322 Record of online time even though dial-up At IP-based readings, online time was recorded even though the dial-up failed. Processing number: 2014-001255 ID: 7527 ZFA-F error message at creating external slaves A database error was logged in ZFA-F if an external IP-T slave was created. Processing number: 2014-001165 ID: 7528 OxCx system basis Settings with null string as value cannot be saved All settings that included a null string could not be saved to the database (even though a changing message was supplied). After restarting the SCS control center the old setting was displayed and used. Processing number: 2014-001055 ID: 6970 System basis 29/10 IP telemetry switching center Remove system configuration "MAX_PUSH_CHANNELS" The system configuration "MAX_PUSH_CHANNELS" was removed. Each communications service always opens one connection to the IP-T master per push target. Thus, reliability can be guaranteed. ID: 6135 31/1 Master data wizard Missing device options at meter installation with master data wizard Now the device options "Move", "Link" and "Neither copy, move or link" can be selected at the metering point option "Without metering point". Processing number: 2014-001153 ID: 7382

70

Customer group is not transferred at meter installation New metering points were always created under the root directory of the user if meters were installed with the master data wizard. The customer group selected in the options dialog was not considered. Now new metering points are created under the correct customer group. Processing number: 2014-001281 ID: 7508 Meter installation of SYM² basic module with superordinated SYM² communication module using the master data wizard If a SYM² basic module with the device option "Copy" was used for a meter installation, the assignment to the communication module remained at the new device. The assignment to a superordinated device is now deleted if the SYM² basic module is copied. Processing number: 2014-001153 ID: 7111 83/1 Standard interface for GAS-X Loading profile data takes very long at event-driven data channels Loading profile data that were counter values took very long at event-driven data channels. Processing number: 2014-001186 ID: 7276 95/Ox Shared time series database Device supplied message "No data existing" after first data reading If a first load profile reading supplied data till exactly 00:00 o'clock, all following readings failed and the error "No data existing" was output. The device types SYM2 and MUC were concerned. Processing number: 2013-001241 ID: 7470 OxCx system basis 100% CPU-Last at function: Start program The macro function "Start program" sometimes generated a CPU load of 100% even if no process was executed. Processing number: 2014-001278 ID: 7490 List of communication modes is displayed In the tab sheet "Communication mode" at a meter which was assigned to a communication module, the main communication mode of the superordinated communication module was displayed. The list "Selection of communication mode" is now hidden. Processing number: 2014-001163 ID: 7229 A route sorting in the MES-F view causes crash of ZFA-F The route sorting in the MES-F view caused a program crash. ID: 6862

71

Missing column at CSV export of the export status of the state control The export status list of the state control can be exported via the "right mouse button" > "CSV export" However, the column "Data channel" was missing in the result file. But it should have been output as well. Now, the export file contains the additional column "Data channel". Processing number: 2014-000864 ID: 6469 Missing French translation The text "New reading" was displayed in German in the French version. Processing number: 2014-001005 ID: 6687 Unable to remove meter: No metering point selected. Now you can select the metering point option "Without metering point" at the options for the meter removal. In this case the meter removal is executed without considering a temporally relation to a metering point. Processing number: 2014-001155 ID: 7358 Web service 96/0 Interface for collection of measuring data Problem at executing function "RenewPassword" in web application "iClient" The functionality "Forgot password?" in the iClient could not be executed if the user type "Internet user" was deselected for the technical user. The error message "This user is no Internet user" was logged. Processing number: 2014-000900 ID: 6908 97/2 Standard Web service interface SOAP calls via "IsRightEnabled" refer to incorrect rights The SOAP interface "IsRightEnabled" supplied the right of the technical user. Now the rights of the user who is logged in are applied. ID: 7212 ZFA-F device drivers electricity 20/4.7 Landis + Gyr: FAG (SCTM) Failed reading of action groups of the EKM 647 (SCTM) If billing data and load profile data were requested at the same time, the second request failed. Neither the right station number nor the right block number was used. Processing number: 2014-001175 ID: 7120

72

22/1.8 Elster: Alpha / AS1440 Overflow by importing incorrect data block If a time out occurred twice at the transmission load profile data, the last block was requested again. Thus, the block was received and imported twice. An overflow occurred. Now the load profile reading is cancelled in blocks if a time out occurs twice in order to avoid duplicated data. Processing number: 2014-001032 ID: 6887 22/11.1 LEM: EM4T/EM4T+ Incorrect behavior at POWER_FAILURE_STATE_N=YES If a gap was to be closed during a power failure and if the data channel contained counter values but status "C" should not be added, the gap was filled with the value "0" and status "N". This caused error at the calculation of the consumptions. Now the gap is filled with the last value before the gap and status "N". The consumptions are calculated correctly. Processing number: 2014-001101 ID: 6886 22/3.12 IskraEMECO: ME382/MT382 (DLMS) Incorrect ID code in billing data record The value of the ID codes 96.1.x was not interpreted as text. Processing number: 2014-001345 ID: 7691 ZFA-F device drivers gas 24/2.4 Elster: EK260 Conversion EK260 fails If there were no archive data at the conversion of billing data of an EK260, then there were no ID codes added for the number of resets . This behavior was changed. If no reset values are existing, the ID code "0.1.0" is added to the record. Processing number: 2014-001122 ID: 6946 24/3.4 FLOW COMP: GAS-MAX++ DSFG standard behavior at an empty time zone has to be implemented If DSfG devices are read, the time zone is determined by reading register "acb". The value of this repository might be empty. This is why a standard behavior which checks the date of the last switch was implemented. If the check fails a time zone without switching is assumed. This change concerns interpreted time stamps in billing data and the supplied time stamp in the load profile. ID: 7402

73

24/7.2 Tritschler: K902/VC2 VC2 supplies empty records If the battery was empty it could happen that a VC2 supplied correct data records without values for the load profile. Importing such data caused a ZFA-F crash. This error is corrected. Now the message "Incorrect import" is displayed at the import. Processing number: 2014-001184 ID: 7145 ZFA-F device drivers different energy types 23/16.1 Wackenhut: IMOD24NV Prevalues cannot be converted The prevalues were not included in the operating values of the register values. Now they are imported with the ID code and the time stamp. Processing number: 2014-001125 ID: 6944 28/10.1 MUC standard Property number is not determined automatically from the server ID at the MUC sensor Up to now only the RWE format was supported. The property number could not be determined automatically if the server IDs used another format. Now the addressing type "wireless" and "wired M-Bus" are supported. Thus, the property number at the MUC sensor can be determined automatically using the server ID according to the FNN specification. ID: 7166 Load profile with unit "varh" imported incorrectly Operating values were calculated incorrectly if the MUC was pushing load profile data with the unit "varh". Processing number: 2014-001107 ID: 6899 In some cases timeslices of the history of constants are not added anymore Sometimes the timeslices were not created correctly at the automatic creation of a constant history. Processing number: 2014-001107 ID: 7383

74

Extensions/ new features/ changes in version 10.14 (Released on: 14/10/2014) Extensions/ new features/ changes New modules 18/14 Macro for automatic post-processing of gaps in load profiles Automatic post processing of gaps by means of pull request at push mode Macro function for automatic post-processing of gaps in load profiles is released. ID: 3847 22/2.14 EMH: EM4TII (IEC1107) Device driver for EMH: EM4TII (IEC1107) New device driver "EM4TII" is released. Processing number: 2014-000431 ID: 5547 New released resources 00/00 New module Release Frötec optical probe BT2IR-II (version 2.4) The optical probe "BT2IR-II" with firmware version 2.4 is released. ID: 5827 44/x HHU program MES-F Cipherlab CP60: Release of the MES-F handhelds The mobile meter reading device "Cipherlab CP60" is released. ID: 6467 Modified modules 20/10.1 Klein & Partner: EDL 4/32 Deletion of module 20/10.1 Klein & Partner: EDL 4/32 Module 20/10.1 Klein & Partner: EDL 4/32 was removed. ID: 5111

75

21/31 EDIFACT/APERAK Extend help regarding the support of the APERAK version 2.1a and CONTRL version 2.0 The help for the MSCONS import was extended at the description of the option "automatically" at the selection of the APERAK version. ID: 6787 Support of the APERAK version 2.1a and CONTRL version 2.0 The MSCONS import creates an APERAK file and a CONTRL file according to the binding guidelines from 01/10/2014. ID: 5960 22/1.8 Elster: Alpha / AS1440 Support of another date format New field "date format" available at the device driver AS1440 VDEW (Elster) in the device dialog at the tab sheet "general". ID: 6693 Support of further date formats Following are supported additionally: "DD-MM-YY" "DDMMYY" "MM-DD-YY" "MMDDYY" ID: 6562 22/16.2 EDMI: Mk7C Separate reading of event logs to reduce the amount of data The device driver for the MK7C was modified to reduce the amount of data. Now, it is possible to indicate the event logs to be read in the device settings of the MK7C. ID: 6264 28/2.1 Dr. Neuhaus gMUC Device driver gMUC Now, the gMUC controller and the connected sensors can be read via HTTP in pull mode. ID: 2044 28/8.3 DSfG bus analysis Communication module DSfG-DFÜ (functionality 2) Now, functionality 2 supports the automatic device installation and the data channel assignment via DSfG bus analysis from all found DSfG devices their archive channels and the corresponding archive group. ID: 3629

76

29/0 Smart Communication Server (SCS) Individual schema for SCS Now, you can access another database schema from the user clients and application servers. The access serves to use a centrally maintained SCS. Processing number: 2013-001347 ID: 3961 31/1 Master data wizard Status output via message box The master data wizard was designed more user-friendly. Now, the dialog shows all relevant messages. Processing number: 2014-000579 ID: 5850 31/7 Administration of SIM cards Extend SIM card import by information "Connection" Now, an additional field can be imported optionally at the import of SIM cards. (Destination: store_device.ident3) ID: 6781 32/4 System monitoring Add monitoring values "Sent orders" The following new monitoring values were added to the ZFA-F application server: - Number of sent orders (OK) - Number of sent orders (Error) - Number of sent orders (Total time frame) - Number of started macros ID: 6188 Add monitoring values "Result check" The following new monitoring values were added to the ZFA-F application server: - Operating state: check for results (active/inactive) - Current number of orders at result check ID: 6187 Add monitoring values "SOAP calls to SCS control center" The following new monitoring values were added to the ZFA-F application server: - Number of sent SOAP calls to SCS control center (OK) - Number of sent SOAP calls to SCS control center (Error) - Number of sent SOAP calls to SCS control center (Total time frame) ID: 6190

77

70/2 Interface Kamstrup Network Engine Prioritization at manual readings The device driver for the Utilidriver was extended. Manually started reading jobs are transferred with the priority "high" to the Kamstrup system. Mass readings started via the macro are still transferred with the priority "normal" ID: 6438 80/11 Standard interface for SAP IS-U Adjustment of the customer format file for the standard installation. (format file isu01f23.ini) Now, the following ID codes are integrated via the SAP IS-U import: - 7-20:3.0.0 to 1.9.0 - 7-20:3.0.1 to 11.06.0 - 7-20:3.0.2 to 11.66.0 - 7-20:3.0.3 to 11.66.0 - 7-20:13.2.0 to 21.9.0 - 7-20:3.2.1 to 21.06.0 - 7-20:3.2.2 to 21.66.0 - 7-20:3.2.3 to 21.66.0 ID: 6240 88/1 Customized extension of the web service interface format 1 Customized web service interface "Correct Enerscape meters" Added new customized web service interface "INTF_09" (Remove meters from Enerscape system). ID: 6704 OxCx system basis Deleting device driver paths (DLL) The device driver entries were removed from the files "zfa_f.ini", "zfa_f_appserver.ini" and "com_f.ini". ID: 6036 Signing of the binary files for the installation All files created by ITF-EDV Fröschl are signed now. ID: 5298 Update WibuKey version 6.00a to 6.30 The WibuKey driver was updated from version 6.01 to version 6.30. Processing number: 2014-000597 ID: 5870

78

Additional customer types/market roles New customer types are available in the customer view. The new types are based on the official market roles. - Imbalance settlement responsible - Balance responsible party - Meter operator - Metered data collector - Smart meter gateway administrator - Manufacturer Two customer types were matched to the official names: - Consumer > Ultimate consumer - Trader/supplier > Supplier The following sections were removed from the file "zfa_f.ini" [CUSTOMER_TYPE] Only the customer types supplied by ITF-EDV Fröschl can be used. [CONSUMER] DLL paths are no longer configurable in the INI file. ID: 872 Errors fixed in this version Automatisms 18/1 Macro for automatic grouping The file "status.dat" is not refreshed anymore The file "status.dat" was not refreshed anymore as soon as a macro with several macro functions was executed. It was a matter of the macro function "Device grouping". Now, the file "status.dat" is also refreshed if a large number of meters is grouped. Processing number: 2014-000801 ID: 6570 18/5 FTP Macro FTP file transfer After transmitting files to the FTP server, the connection had to be disconnected and established again in order to display the transmitted files to check whether the transmission was successful. Now, the menu item "Refresh F5" is available in the following context menus: - local tree structure - local file list - remote tree structure - remote file list ID: 4874

79

31/6 Dynamic View Limited characters for SQL statement The limitation to 4096 characters for SQL statements in the dynamic view was removed since it was not required. Processing number: 2014-000775 ID: 6448 Calculations 30/15 Generation of substitute values by interpolation procedure Crash of ZFA-F at linear interpolation ZFA-F crashed if the linear interpolation was executed with the settings "Apply to all values" and "Invalid with status combination C OR N". Now, the generation of substitute values is executed correctly if the settings "Apply to all values" and "Invalid with status combination C OR N" are selected. Processing number: 2014-000991 ID: 6668 30/16 Generation of substitute values by direct comparison Generation of substitute values by means direct comparison (automatic copying) ignores tariff assignment The tariff assignment of the target data channel was ignored if substitute values were generated with the method "Copy". Processing number: 2014-000672 ID: 6551 Database interfaces 21/19.2 EDIFACT/MSCONS interface VDEW export MSCONS export fails An error occurred at the MSCONS export version 2.2c if "Supplier number" was selected as sender and receiver. Now, the sender and receiver can be selected as desired. Processing number: 2014-000914, 2014-000934, 2014-000951 ID: 6589 91/1 Interface for component-based access Function "ExecuteJob" reads too many channels There were too many data channels read if a load profile reading was executed via the web service function "ExecuteJob". The OBIS ID code 1-1:1.9.0 was filtered. However, the channels with the ID code 1-3:1.5.0 was read and imported as well. Now, only those data channels whose ID codes are requested explicitly are read. Processing number: 2014-000865 ID: 6494

80

OxCx system basis No manual reading possible after faulty reading of new billing data channel A manual reading could not be executed after a faulty reading of a new billing data channel. Processing number: 2014-000953, 2014-000959, 2014-000992 ID: 6577 Database structure Option "Wait for application execution" at "Start program" does not work Now, the macro function "Start program" also works under Windows XP if the option "Wait for application execution" is selected. Processing number: 2014-000885 ID: 6613 Data import 40/x Interface for mobile meter reading (MES-F) Import is cancelled if certain devices are selected If you have selected the option "Select certain devices" at the HHU import format 2, following message was supplied: "It was tried to execute a process which is not supported". The import was cancelled if this message was confirmed with "OK". Processing number: 2014-000752 ID: 6388 OxCx System basis GM import sets status "I" at true values At the Sym² true operating values were always overwritten independent from the INI settings. Whether operating values are overwritten now depends on the settings made in the INI file. Processing number: 2014-000998 ID: 6809 Data transmission 16/0 Configurable export Script export with template "Raw data (billing data)" The export was cancelled due to a run time error if the export script "print02f.sct" was started as macro and a data channel without data was selected. Now, the export script is executed correctly in the automatic mode even if data channels without data are selected. Processing number: 2014-000949 ID: 6573

81

21/24.2 EDIFACT/MSCONS interface VDEW export Asserts at MSCONS export of a summed load profile An incorrect value for the validity time stamp was written to the corresponding database field if a load profile calculation was created or reset. Processing number: 2014-001059 ID: 6795 21/29.2 EDIFACT/MSCONS interface Edi@Energy Export Validation indicator is not exported The validation indicator was not exported at the MSCONS export version 2.2c. Processing number: 2014-000952 ID: 6590 80/11 Standard interface for SAP IS-U Assigning data channel fails So far the entry "TRIM_LEADING_ZEROS" in the INI file "ifisu053.ini" was set to "YES". For this reason the data channel could not be assigned at the import. Now, this option is set to "NO" and the data channel can be assigned correctly at the import. Processing number: 2014-000954 ID: 6615 iClient 60/x Internet module / iClient SIMGR error at event log reading A SIMGR error occurred if the event log was read in the iClient at selecting the balances under the data view. Further readings could not be executed. Processing number: 2014-000802 ID: 6370 Error message at the installation wizard The error message "Enter all values" was output if an IP address was entered for the MySQL host at the installation wizard. This was caused by a failed MYSQL connect. The reason were missing rights for the host defined via IP. The error resulting from this was not determined correctly and an incorrect default error message was output. ID: 6424 Button "Watch lists and messages" is supplied even if rights / modules do not exist If the button "Schedule control" was clicked, the two modules "Messages and Watch lists" were displayed in the menu even if the corresponding license was not active. The identification of rights was adjusted correspondingly. ID: 6801

82

Customized interfaces 88/1 Customized extension of the web service interface format 1 English help for customized web service interface "Correct Enerscape meters" is missing The English help for customized web service interface "Correct Enerscape meters" was missing The help was translated to English. ID: 6818 Help for customized web service interface "Correct Enerscape meters" is missing The new function "Inft 09" was not described in the corresponding help. The help for customized web service interfaces was extended by the new function. ID: 6793 Customized Web-service interface MDM.Query5: Consideration of time slice definition The interface function determines the corresponding time slice / assignment to the meter for the current time. If there is no active assignment at the current time, the result for the metering point / meter remains empty. ID: 6703 Interfaces for MES-F 41/7 Order monitoring Text entry of the status is missing in the statistic for reading orders The field "Status" was not displayed at the statistic of reading orders. Processing number: 2014-001041 ID: 6750 44/x HHU program MES-F Edits meter number The extended plausibility check was not considered. Now, the meter number is taken from the billing data record, according to the indications. Processing number: 2014-000823 ID: 6433 MES-F could not be started after installation on an IPAQ 214. The device "IPAQ 214" could not be installed correctly after a reset. An operating system update has to be installed. The certificate was exchanged. Processing number: 2014-000726 ID: 6505

83

French field names at MES-F interface too long The names of some fields at the French MES-F interface were too long Due to this, the representation of the field content was very confusing. The field names were shortened as defined by the customer. Processing number: 2014-000788 ID: 6382 47/28.6.2 GWF: FunkRMM-PI 4 (Wireless M-Bus EN 13757) Crash at radio reading A memory exception occurred at a radio reading if the device drivers were loaded. Processing number: 2014-000883 ID: 6499 SCS 29/0 Smart Communication Server (SCS) Upcoming callback orders are not processed Upcoming callback orders were not processed if a pull order was executed via the COM port which was configured as callback. ID: 6811 Extended log messages concerning the control center initialization The log messages of the SCS control center were extended. ID: 6796 Incorrect representation of communication data at web interface The sent data were not displayed blue but green on the web interface of the SCS if cascaded devices were read. ID: 3624 Failed reading via IP-T message "Device not logged in" Cascaded IP-T devices could not be determined to be already imported. Processing number: 2014-000957 ID: 6621 GUI: Displaying all resources for a new communications service fails Creating a new communications service on the SCS web interface failed if you wanted to display all available resources (network adapter, COM ports) by clicking the refresh button in the resource dialog. ID: 6844 The ID of the communications server is written to the messages not the name Sometimes the database ID was written to the communication messages instead of the name of the communications server. Processing number: 2014-000936 ID: 6569

84

Push results are copied twice to the archive Sometimes push results were copied twice to the archive. ID: 6568 29/10 IP telemetry switching center Updating system configurations failed at restarting the IP-T master System configurations were not updated at starting the IP-T master Thus, it could happen that inconsistent data were not corrected at a restart. ID: 6339 Master data transfer 70/1 Interface Echelon NES Error messages at synchronizing meter with NES function The check whether the command for "Continuous load profile reading" has to be added was improved. The meters are not assigned to a concentrator with an invalid ID anymore. Processing number: 2014-000658 ID: 6212 93/1 Standard interface for master data transfer ZFA-F Additional data are not selected at an existing metering point Adding additional data to exiting metering points by means of the master data transfer caused an error. Processing number: 2014-001063 ID: 6832 System basis 31/1 Master data wizard ASSERT at metering point option "Without metering point" The meter installation with the metering point option "Without metering point" caused an error at the master data wizard. Processing number: 2014-001087 ID: 6850 Field "Data channel name" missing at master data wizard Only the field for describing the data channel was displayed on the user interface of the master data wizard. The field for the data channel name was missing. It was added to the list of fields to be displayed. ID: 6669

85

OxCx system basis Reading statistics: Value for column too long An error occurred at the reading statistics if the value for the customer title exceeded the column width. Now, only the maximum number of characters for that field is written to the print database. Processing number: 2014-000981 ID: 6734 Adjusted translation of status information (installation status) The Latvian translation of the status information (interface ZFA-F) was incorrect. The translation was adjusted according to the requirements of the foreign distributor. Processing number: 2014-000891 ID: 6548 Display "first/last record" failed The buttons "First record" and "Last record" did not work in the data view at billing data record that were not converted. Processing number: 2014-000853 ID: 6472 Constraint error at writing the action history A constraint error occurred at writing the action history if it was a repetition. Processing number: 2014-000709 ID: 6446 Extension of messages because of deadlock of the automatic Additional messages are output at the recalculation of a schedule if a problem is detected. Processing number: 2014-000761 ID: 6528 Error at editing the status The status could not be edited in the data view of a 64-bit version. The message "Status" was output. Processing number: 2014-001029 ID: 6745 Incorrect display of the data channel properties (tariff structure) The settings of the tariff structure in the data channel properties were not displayed completely if ZFA-F was not opened in full screen mode. The scroll bar ended before the complete settings could be displayed. Processing number: 2013-001336 ID: 3943 Cyclic refresh executed too often in device view The device view was refreshed too often. Speed improvements in the tree structure now depend on the number of devices under a device group. Thus, disturbing effects of the cyclic refresh can be avoided. Processing number: 2014-000814 ID: 6466

86

Installation Sybase ODBC with additional tool Existing ODBC entries in the INI files were overwritten at the installation of Sybase. Processing number: 2014-000693 ID: 6089 Object list editor (Object list, RegDefEditor) via SCS There was a note missing in the help concerning the fact that only object lists for certain device drivers are saved to the database. Now, the help contains a list of the corresponding device drivers. Processing number: 2014-000887 ID: 6515 Day balances are not created for event-driven channels At the GasX export there were no data exported for event-driven channels even though the reading was successful. Now, the last reading time frame is considered. Thus data can be exported even if no day balances are available. Processing number: 2014-000968 ID: 6665 Additional data are not copied if customer is copied If a customer was copied, its additional were not copied. Processing number: 2014-001071 ID: 6803 ZFA-F device drivers electricity 22/1.8 Elster: Alpha / AS1440 Communication module AM100 - "Unknown exception" An unknown exception occurred while reading an Elster AM100 with Object list 2 and Regdef 3. Now, it is checked whether an access error occurs while reading single attributes. Processing number: 2014-000887 ID: 6513 22/16.2 EDMI: Mk7C Leading zero missing at reset counter The device driver MK7C did not normalize the read value of the reset counter to 2 digits. This behavior was changed and one-digit resets are displayed with a leading zero. ID: 6314

87

ZFA-F device drivers gas 24/2.1 Elster: DS100 Crash at importing billing data If the gas meter EK-88 was read with the driver DS100, ZFA-F could possibly crash at the import of the register values. Processing number: 2014-000846 ID: 6456 24/2.6 Elster: DL210 Importing load profile to ZFA-F failed If a load profile of the DL210/DL220/DL240 was read by means of MES-F, without defaults and without template device, the import to ZFA-F failed. Processing number: 2014-000824 ID: 6484 24/2.9 Elster: EK280 (IEC1107) Missing messages event log Sometimes the EK280 supplied the message "Unknown message" while importing the event log. The messages of the EK280 were extended and matched to the current description. ID: 4163 24/8.1 Wieser: MRG910 (DSfG) Message is written too often and to the wrong category At the raw data import of load profiles of DSfG devices the message "No info, whether device executes daylight saving/standard time switch" was output very often. This behavior was changed. Now, the load profile data are imported in standard time. ID: 6372 ZFA-F device drivers different energy types 23/16.1 Wackenhut: IMOD24NV Meter reading of the EK260 via meter modem "I-MOD24NV" does not work Reading the meter "EK260" via the meter modem "I-MOD24NV" did not work. The meter did not react to ID code 1:181.0. ID: 6555

88

23/2.3 Görlitz: ENERCOM400(E/G) Incorrect reading at certain action group constellation Requesting VDEW meters with connected Enercom400 modem via SCS did not work if the meter reading was set before a load profile reading in the action group. Processing number: 2014-000860 ID: 6507 28/10.1 MUC standard 0.9.1 and 0.9.2 missing in MUC register data record If a MUC supplies the Unix time stamp with ID code 0.9.11*0 in the register data record, the device time is added with the ID codes 0.9.1 and 0.9.2. Processing number: 2014-000868 ID: 6563 0 values of gas devices are not displayed Load profiles of gas meters were not imported anymore at the MUC sensor. Processing number: 2014-000834 ID: 6535 28/2.1 Dr. Neuhaus gMUC Help for device driver gMUC is missing There was no help available for the device driver "gMUC". The help was created and can be accessed from ZFA-F via "F1". ID: 6592 47/28.6.2 GWF: FunkRMM-PI 4 (Wireless M-Bus EN 13757) Add AES key for module "ITRON Cyble wM-Bus" The AES key for the radio module "ITRON Cyble" was added. Processing number: 2014-000835 ID: 6545 Analyze medium and error status correctly The medium "Water" was converted to the medium "Cold" (OBIS ID code 5). Now, the original telegram status is logged. Furthermore, the OMS medium 7 "Water" was converted to the OBIS medium 8 "Cold water". Processing number: 2014-000835 ID: 6541

89

70/2 Interface Kamstrup Network Engine Too many messages are written while executing the Utilidriver macro Two messages for each synchronized device were written at the synchronization via the Utilidriver macro. If several thousand devices were maintained, an accordingly high number of messages were written to the database. The synchronization messages were set to "DEBUG". Thus, they are not written to the database anymore. Processing number: 2014-000833 ID: 6462 All load profiles channels are read at a group reading If the macro "Synchronize Utilidriver" was used at a group reading of the load profile data, even registers of inactive or non-existing data channels were read. Now, the registers of inactive or non-existing data channels are read anymore. This improve the reading time of a group reading of load profile data. Processing number: 2014-000818 ID: 6415 Time frame determined incorrectly at executing the macro The reading time frame was calculated incorrectly at reading a load profile of a device group if a relative time specification was indicated. Now, the beginning of the reading is matched correctly to the device including the oldest data. The end of the reading is calculated individually for each reading. It is not read from the database anymore. Processing number: 2014-000818 ID: 6414

90

Extensions/ new features/ changes in version 10.13 (Released on: 07/08/2014) New modules 24/2.7 Elster: DL230 (IEC1107) Device driver for Elster: DL230 (IEC1107) Module 24/2.7 Elster: DL230 (IEC1107) is released. ID: 5028 32/4 System monitoring The following options are available with the system monitoring: Monitoring • available for the following system components: ZFA-F, ZFA-F application server, SCS control center, SCS communications service, SOAP Instance Manager • each system component and each monitoring value is activatable and configurable separately • specific monitoring values per system component Data supply • as file • current status of the corresponding monitoring value • provisioning method and interval configurable • provisioning method 1: Single value file with current status • provisioning method 2: Consecutive protocol of the current status in CSV format • provisioning method 3: Consecutive protocol inside integration period raster in CSV format Configuration • central configuration of the monitoring via ZFA-F • central saving of configurations in the ZFA-F database • automatic distribution of the configurations to the system components • local buffering via the corresponding system component for initial behavior / connectionless operation ID: 1017 32/4 System monitoring Configure and distribute monitoring settings centrally The monitoring settings can be configured in ZFA-F under "Administration" > "Options" > "Monitoring Framework". Those settings are saved centrally to the database. ID: 2112

91

New released resources OxCx system basis Release request for Windows Server 2012, Windows Server 2012 R2, Windows 8 and Windows 8.1 The 64-Bit operating systems - Windows 8 - Windows 8.1 - Windows Server 2012 - Windows Server 2012 R2 are released. Processing number: 2012-001173 ID: 995 Extended modules 18/1 Macro for automatic grouping Extension of the device grouping criterion "Reading data available" by option "Additional profile status" Now, you can define missing / incorrect measuring values at load profile data via an additional option dialog for the criterion "Devices with existing reading data" at the device grouping measuring via the selection of the ZFA-F statuses or errors of the plausibility check. Processing number: 2013-001129 ID: 3591 21/26.2 EDIFACT/MSCONS interface Edi@Energy Export Support of MSCONS version 2.2c and related OBIS version Extension of the EDIFACT/MSCONS interface for the import and export with MSCONS version 2.2c ID: 5402 22/21.1 SATEC: EM720/ EM720T - functionality 1 Add additional ID codes to billing data according to customer requirements The driver EM720 was adjusted. Now, reading further registers is supported. Find further information about the new registers in the help for the EM720 under "Configuration file". Processing number: 2014-000489 ID: 5655

92

22/5.11 Landis + Gyr: ZxF100 Series 2 - functionality 2 Added action "Switch relay outputs" (Ethernet module) Added data channel type "Digital output (switching output)" with the corresponding data channel actions ("switch relay output"). Processing number: 2013-000908 ID: 2904 28/8.2 DSfG standard (DSfG) Communication module DSfG-DFÜ (functionality 1) Now, functionality 1 supports cascaded reading of subordinated DSfG devices at the DSfG-DFÜ. ID: 3200 30/26 Generation of substitute values load profile from register values Considering maximum values at the generation of substitute values with the method "Load profile from register values" The substitution method "Load profile from register values" was extended by the functionality "Consider maximum". ID: 4520 Extend help for considering maximum values at substitution method "Load profile from register values" The description for considering maximum values at the substitution method "Load profile from register values" was insufficiently. The missing content was added. Now, the help includes all information for considering maximum values. ID: 6073 40/x Interface for mobile meter reading (MES-F) Default user ID from INI file The default user ID "254" and the default address "1" is used at readings without defaults. Those settings can be changed in the file "em1020.ini" with the entries "USER_ID" and "ADDRESS". Processing number: 2013-001018 ID: 3071 62/X Web portal Integration period-precise display of daily values (instead of hour values) Up to now the day view was displayed with 24 hour values. Only if you zoomed an hour value the single integration periods were displayed (e.g. at 15 min. the four values of the selected hour). Now, the single integration periods are displayed in the day view if the corresponding configuration was set (config.inc.php: DAY_VIEW_WITH_ORIG_MP - true. Processing number: 2014-000543 ID: 5780

93

70/1 Interface Echelon NES Support of a new version of the meter EM1020: Reading maximum values and prevalues Maximum values and the corresponding prevalues are supported. ID: 5785 94/Ox Extended database API for Oracle database Extension of the DBI_PROFILE by function Get_Last_Day The database package DBI_PROFILE was extended by the function GET_LAST_DAY which is used by the SOAP function "GetLastDay". The installation of the Oracle database package XML DB is required for working with XML! ID: 6012 Modified modules 23/2.3 Görlitz: ENERCOM400(E/G) Transfer of constants from raw data to the history of constants The pulse constant of the load profile data channel can be transferred automatically from the data to the master data at the Enercom400. For this a new entry was added to the file "ener400.ini": AUTO_SCALE=NO This functionality is deactivated by default. ID: 5256 70/1 Interface Echelon NES Selecting reading keys at reading without defaults You can maintain a password list in the file "em1020.ini" for readings using the protocol "ANSIC12". The names of the passwords 1 to n are provided in the selection list in the corresponding menu of the handheld program at a reading without defaults. ID: 5973 44/x MDG program MES-F MES-F could not be started after installation on an IPAQ 214 If a clean boot has been carried out, a cab file which is updating the time zones has to be installed on the IPAQ device ID: 6167 OxCx system basis Deleting the files"recalcdt.ini" and "archives.ini" The files "recalcdt.ini" and "archives.ini" were removed from the installation. Selected settings concerning the recalculation and archiving/dearchiving of operating values were added to the file "zfa_fs.ini". ID: 5377

94

Deleting the file "cnvedit.ini" The file "cnvedit.ini" was removed from the installation. The user-specific settings SCRIPT_EDITOR, USE_STATISTIC, USE_FILTER, COPYPATH_LEV2SCT, LAST_NEWIDENT, LAST_NEWFILE were added to the file "zfa_fs.ini". ID: 6002 Extension of the macro function "Delete" by function "Deleting devices" The macro function "Delete” was extended with “Deleting devices”. ID: 2950 ID Management of high IDs via Stored Procedure (sequences) for Informix IDs for large tables are generated by sequences. Due to security reasons there is a waiting time of 4 minutes if more than 100,000 IDs are created per hour. This process is logged. ID: 4879 Add empty SQLite database to installation Now, the files "zfa_f_arc.db" and "empty.db" are supplied at each installation. They do not have to be requested at our support team anymore. ID: 5719 Errors fixed in this version Automatisms 18/13 Macro for connection to mail server Missing message entries at macro function "Receive e-mail" The messages "Macro incorrect" or "Macro OK" for the macro functions "Receive e-mail (IMAP)", "Receive e-mail (POP3)" and "Send e-mail (SMTP)" were not displayed after executing the functions. Processing number: 2014-000507 ID: 5702 18/6 Multi automatic client with fix schedule assignment Expired schedules block schedule control After a calculation / check, the status field "Next execution" was not marked as "expired" for nonrecurring schedules having a start time in the past. However, they were still considered for a new schedule calculation and thus blocked the execution of other schedules. ID: 5893

95

OxCx system basis Constraint violations at deleted schedule If a schedule for which reading results were missing was deleted, the action history could not be written after importing the results (constraint violation). Processing number: 2013-000630; 2014-000511 ID: 6210 Calculations 30/18 Generation of substitute values by manual import of comparison measurements Incorrect automatic generation of substitute values - tariffs are only transferred partially The tariff of the source was not transferred if the setting "Previous week days" and the option "Accept source tariff" was selected at the substitution method "Copying" . In this case transferring the source tariff does not make sense since a substitution value created with the setting "Previous week days" can be an average value of several profile values of different days. Now, the option "Accept source tariff" is not selectable anymore for this method and the tariff of the target channel is transferred instead. Processing number: 2014-000672 ID: 6158 30/27 Generation of substitute values for register values from load profiles Substitute Value Wizard not available if modules 30/27, 30/28 and 30/30 are used individually The Substitute Value Wizard was not available if only one of the substitution modules 30/27, 30/28 or 30/30 was active. Now, the Substitute Value Wizard is also available if only one of the modules 30/27, 30/28 or 30/30 " is active. ID: 5998 30/3 Time related calculations Load profile calculation cannot be started The standard method for generating substitute values was displayed incorrectly at loading a load profile calculation. ID: 5902 Load profile calculation is not calculated completely At the recalculation of a load profile calculation, the validity time stamp of all evaluations which define this load profile calculation as source channel is reset to the corresponding value. During this process, all involved database tables are locked. The locking of the tables failed sporadically due to an error in the program. However, the recalculation was continued whereas the reset of the validity time stamp was skipped due to this error. This caused data gaps at the involved evaluations. Now, the locking of the corresponding databases works correctly. The recalculation is canceled in case an error occurs at setting the validity time stamp. Processing number: 2013-000534 ID: 5447

96

30/30 Generation of substitute values of register values from register values Not all register values included in the substitute value billing data record get status "E" or "IE" Not all calculated substitute values were assigned to the status indicated under "Set status" at the substitution method "Register values from register values" ID: 6034 31/6 Dynamic View Same name displayed for all elements of a virtual group Elements of a virtual group are still displayed correctly in the dynamic view even though they were opened and closed several times. Processing number: 2014-000137 ID: 4842 Database interfaces 21/19.2 EDIFACT/MSCONS interface VDEW export Export was cancelled if ID code conversion was missing If there was an error at the ID code conversion, the MSCONS export was cancelled at activated state control. In case of an error the export will be continued with the next data channel. Processing number: 2014-000757 ID: 6303 Data import 31/7 Administration of SIM cards Missing entries of import file for SIM card The field "Module number" in the import file was transferred to the wrong database field. Now, the module number is imported to the field "Store_Device.Ident4". Processing number: 2014-000705 ID: 6228 SIM card import The field "IMSI" was not filled by the import to the device. Processing number: 2014-000705 ID: 6101

97

Data transmission 21/29.1 EDIFACT/MSCONS interface Edi@Energy import Export was cancelled if maximum number of segments with additional status was exceeded The MSCONS export was cancelled if the maximum number segments in segment group 10 was exceeded and if an additional status was existing. Now, the number of additional statuses is not limited anymore. Processing number: 2014-000724 ID: 6186 21/29.2 EDIFACT/MSCONS interface Edi@Energy Export Export of energy values So far MSCONS only supported the export of energy channels or volume channels for the energy type "gas", controlled by the option "Export as energy values". Independent from this option, energy channels and volume channels can be exported at the same time with the same macro function. Additionally, the calorific value of the assigned calorific value channel, if existing, is exported as well if the values are energy values. Processing number: 2013-001539;2013-001649 ID: 5007 No data transfer at 0C values There was no export file created at the export of load profile data with the option "Load profile for arbitrary time frames" or from version 2.2a if there were no data within the export time frame and if the state control was deactivated. Processing number: 2014-000645 ID: 6009 Option "Only export complete days" The option "Only export complete days" was not available for exporting load profile data at the MSCONS versions 2.2a and 2.2b if the energy type "Electricity" was selected and if an older version with the option "Day load" was selected previously. Processing number: 2014-000465 ID: 5605 iClient 60/x Internet module / iClient Loading balances at iClient takes very long If a load profile calculation was highly interlaced, loading balances took very long (several minutes). The complete time frame was recalculated by mistake. Now, only the time frame that was not calculated is recalculated. Thus, a high-performance display is guaranteed. Processing number: 2014-000324 ID: 5764

98

Interfaces for MES-F 40/x Interface for mobile meter reading (MES-F) Communication mode via BT2IR cannot open assigned COM port The COM port name was incorrect. Now, the correct name is used. Processing number: 2014-000687 ID: 6049 MES-F with time zone "GMT+2 Helsinki, Riga, Sofia" The selected system time zone was not set. Processing number: 2014-000553 ID: 5799 41/8 Macro for automatic order sorting Order sorting assigns incorrect route Processing of the default route was not considered. Now, the route is generated on the basis of the correct database field. Processing number: 2014-000502 ID: 5826 44/x HHU program MES-F MES-F installation on iPAQ hx2490 Installing MES-F on the handheld unit iPAQ hx2490 failed. Processing number: 2014-000397 ID: 5720 SCS 29/0 Smart Communication Server (SCS) Crash of MessageQueue thread after CC switch If a standby control center turned into a master, the MessageQueue thread crashed in some cases. The process was still running and orders were accepted but not processed. Now, the control center is cancelled if the process base for processing the orders does not exist anymore. ID: 6230 Incorrect description of deactivation modes The reactivation time of the deactivation modes was indicated in milliseconds in the SCS help. An indication in minutes would be correct. The indication in milliseconds was replaced by the indication in minutes. Processing number: 2014-000584 ID: 5855

99

Recall function does not work Recall function does not work at the SCS ID: 6281 Master data transfer 93/1 Standard interface for master data transfer ZFA-F Master data transfer did not work at template devices at which the protection from accidental editing and deleting was activated The import did not work if the template devices of the master data import were assigned to the protection from accidental editing and deleting. Now, the master data import can also process elements which are assigned to the protection from accidental editing/deletion. ID: 5269 System basis 28/5.2 Hydrometer: IZAR-Center Memory Action "Date/time" at device IZAR-Center in standard time Up to now the device driver IZAR-Center Memory interpreted the read time as daylight saving/standard time switch. That is incorrect. Now, the IZAR-Center Memory supplies its time in standard time. The device driver was adjusted correspondingly. Processing number: 2013-000604 ID: 2520 OxCx system basis Crash of dbupdate6.exe The database update crashed right after starting an update from ZFA-F version 03.209 to ZFA-F version V10. Now, the database update can be executed without problems. Processing number: 2014-000633 ID: 5988 Crash of ZFA-F due to incorrect paths in INI file (zfa_f.ini) ZFA-F could not be started if the path to the log file was incorrect. In this case an entry is written to the file "zfa_f_fault.log" and a message box including a note regarding the invalid file is output. ID: 6104 The integrated link did not work on 64-bit operating systems if the help was opened without ZFA-F. The help files were not registered correctly if a 32-bit version of ZFA-f was installed on a 64-bit operating system. This caused problems concerning the navigation within the help if the .chm file was opened directly. Now, the .chm help files are registered in both registry directories if a 32-bit version of ZFA-F is installed on a 64-bit operating system. ID: 687

100

Automatic client unable to import The automatic client did not import reading results under following conditions: - There are no reading results (there is no reading order in the database for which reading results are still expected). - Automatic client does not process push data due to its configuration - Automatic client does not send any reading orders to the SCS-CC/COM-F itself. ID: 6191 Automatic device installation always creates device group AUTOCREATE The automatic device installation always created the device group AUTOCREATE with subordinated device groups. Those are only saved if a device is created. Processing number: 2013-001502 ID: 3682 Description how to uninstall ZFA-F is missing in the installation manual The description how to uninstall ZFA-F was missing in the installation manual. Now the help contains a topic called "Uninstalling ZFA-F". This topic describes how to uninstall ZFA-F. ID: 5560 Bugfix cannot be installed A bug fix installation was cancelled if the PE signatures could not be determined. Now, the user can decide which version he wants to install (32-bit or 64-bit). Processing number: 2013-001236 ID: 3686 Deactivation of the option "Rename dividing line" under "Favorites" You can add a dividing line between the different favorites in the dialog "Edit favorites". It was possible to rename the dividing line. However, the changed were not saved. The option "Rename dividing line" was removed. It is only selectable for renaming favorites. Processing number: 2014-000109 ID: 4963 Services were uninstalled during an installation and installed again afterwards Up to now the required services were uninstalled during an update installation and installed again afterwards. Now, the services are stopped if the update is started. Afterwards they are updated and restarted if the installation is finished. An uninstallation with the installation package of the version that is already installed is executed before an update is installed. For this reason the change only applies to updates from version 10.13 to a new version. ID: 5871

101

Print options in the options dialog are not used anymore From version V10.x files cannot be printed out of COM-F. The section: [DATABASE] PRINT=zfaprint PRINT_UID=dba PRINT_PWD=sql was deleted from the file "com_f.ini". ID: 5427 DSfG-DFÜ is not displayed as communication module in the tree structure The device type DSfG-DFÜ was not displayed as communication module in the tree structure. ID: 5976 Edited template for standard ID code system cannot be saved The edited template of an arbitrary standard ID code system could not be saved. Processing number: 2014-000631 ID: 5956 Error at container import after an interruption of the Informix database connection. An error occurs at the import of containers after an interruption of the database connection. Now, containers are imported without error if the database connection could be restored on success. ID: 6300 Error at updating the file file "error calling zip.exe" Errors occurred at creating an INI file during an update installation. Settings required by the installation were saved to this file. The installation was cancelled if the file was faulty. Now, those settings are not saved to the INI file anymore but transferred during the installation. Thus, the intermediate step to access the INI file is not necessary and the installation is not cancelled anymore. Processing number: 2014-000690 ID: 6060 Search for devices fails at Microsoft SQL Server A standard search in a Microsoft SQL Server database was cancelled if the search was executed in an automatic client. Processing number: 2014-000433 ID: 5735

102

Error message "attempt xxx a free ID in table xxx " Unique IDs are required for saving database records to the database. Those are generated for all database tables via random numbers. At following tables conflicts occurred due to the large quantity of data records: - ACTION_EXEC_ATTEMPT - ACTION_EXEC_HISTORY - LOG_TRANS - LOG_VAL - PROFILEDATA - RESULTDATA In order to avoid those ID conflicts it is now possible to create the IDs via a subsequently installed stored procedure by means of sequences. In this case, the range of the created IDs is 1 to 2^63. Processing number: 2012-000905 ID: 1093 The field "Type of energy" is not filled in the order unit If the medium was output without address in the overview of the order unit, the information could not be loaded. Now, the information concerning the data channel can be loaded independent from the address. Processing number: 2014-000198 ID: 5916 Field "Method" at generation of substitute values stays empty The method "Copy" was not displayed at generating substitute values for a load profile channel even though the right for this method was existing. Processing number: 2014-000646 ID: 6006 Device link remains even if the assignment is deleted If the assignment of a device to a communication module was removed, a device link in the device group of the communication module remained. Now, this link is removed as well just like at the deletion of an assignment in the tree structure via the deletion function. Processing number: 2012-000895 ID: 563 Adding a time frame at the history of constants The right 786 (display tariff structure assignment) was set to "inactive". The window "History of constants" was opened via the data channel properties. There you could add an additional, active time frame with another transformer factor. It was not possible to save the changes since the saving button was inactive. Since the tariff structure assignment is not changed, it is not necessary to check whether the right 786 is available or not. It was removed. Processing number: 2014-000281 ID: 5238

103

Event log reading is generated from the wrong time frame Now, software messages (e.g. setting date/time) are not considered in determining the time frame for event log reading. Processing number: 2014-000728 ID: 4808 Macro function "Deleting device groups" can be saved without name So far the macro function "Deleting device groups" could still be saved if the field "Name" was selected but not filled. Now, a warning is output in such case and it is not possible to save the macro function. Additionally, the note "Warning: Filters that are set incorrectly can result in a loss of data" is output at saving this macro function. ID: 5982 SOAP Instance Manager does not react anymore after several invalid requests If several SOAP requests with invalid session IDs were sent to the SOAP Instance Manager, the server started to react very slowly since this was deemed to be a potential attack. The security measure was improved. It is only applied to users who permanently send invalid requests. ID: 6028 Parallel representation of load profile channels The parallel display of load profile channels in a chart is only possible if the selected load profile channels have the same day change. This characteristic is no described in the corresponding help. Processing number: 2014-000504 ID: 6074 Script adjustment is not applied until ZFA-F was restarted Script adjustments concerning the settings of the section "INIT" (e.g. TARGET) were not applied until ZFA-F was restarted. Now, export scripts are not taken from the buffer memory but they imported at each execution. Thus, changes of certain settings are applied without restarting ZFA-F. Processing number: 2013-000805 ID: 2738 SentinelHASP is not installed after new installation of ZFA-F The SentinelHASP dongle was installed at the first installation and uninstalled in one of the subsequent steps. Now, the dongle is only uninstalled if the software is uninstalled as well. ID: 5813 SentinelHASP could not be installed on Windows 8 SentinelHASP could not be installed on Windows 8 Now, the SentinelHASP version V6.63 is used. ID: 6154 Sheet of the macro group is supposed to be empty at loading an action group If an action group was loaded and selected in the tree structure of the dynamic view, error messages appeared at starting the view if you tried to load a macro group. This is avoided by displaying an empty sheet. Processing number: 2014-000123 ID: 4940

104

Sporadically freeze of application server The automatic clients sporadically freezed if the Informix database version 12.10.TC3 was used. Processing number: 2014-000670 ID: 6093 Time series loader not initialized at restoring the database connection A TSL_PUT error occurred after restoring a database connection. Now, the time series loader is initialized after the database connection is restored. ID: 6056 TSL_PUT error at Informix database A TSL_PUT error occurred if load profile data were saved because the time series loader was closed too early. Now, the connection to the time series loader is closed after you have logged out from the database. ID: 5823 Wrong translation substitution method register values from register values The wrong translation results from a too short field in the ZFA-F interface. The translated text could not be fully displayed. The field was extended in order to display the complete text. ID: 6019 Changes regarding the meter value status are not logged at the messages of the meter data history Changes of the meter value status of a 0C value made by a user were not logged. Now, a message is written to the log file if the meter value status of a 0C value is changed. Processing number: 2014-000481 ID: 5649

105

ZFA-F device drivers electricity 22/16.2 EDMI: Mk7C Communication is not cancelled if incorrect data are received At a request of billing data of an MK7C it could happen that an error message was written if the reading of a register was incorrect. However, the status code in the container was not changed correspondingly Following characteristics were implemented into the driver: - The reading is cancelled and the status code "Incorrect protocol flow" is written to the container if an error occurs during the communication. - The communication is continued if an error occurs during the evaluation of received data. However the status "Incorrect master data" is set. Processing number: 2014-000327 ID: 5562 Entry in the MK7C INI file incorrect The description of the configuration file of the device driver "MK7" contained the entry "LOD_ID1=". That was a typing error. The correct name is "LOG_ID1=". The name of the entry was corrected correspondingly in the help. Processing number: 2014-000700 ID: 6113 LOG_ID1 entries are missing in the MK7C.INI The entries for reading the different event log were missing in the INI file for the device driver MK7C. That is why, so far, all event logs were read. The missing entries were added. Processing number: 2014-000700 ID: 6114 LOG_IDx entries are missing in the system configuration of the SCS It was not possible to select the event logs for the MK7C on the web interface of the SCS. The settings were added. Processing number: 2014-000700 ID: 6117 22/20.1 ITF/Reallin: E3010 Detailed information regarding the content of the billing data record incorrect All billing data records of the E3010 were automatically assigned to the content type "Current values". This characteristic was changed. The billing data record is assigned to "Current values and resets" if current values and prevalues are read. If prevalues are separated from the record including the current values, the data records including the prevalues are assigned to the content type "Automatic reset" ID: 5946

106

22/20.2 ITF/Reallin E1000-03 Detailed information regarding the content of the billing data record incorrect All billing data records of the E1000-03 were automatically assigned to the content type "Current values". This characteristic was changed. The billing data record is assigned to "Current values and resets" if current values and prevalues are read. If prevalues are separated from the record including the current values, the data records including the prevalues are assigned to the content type "Automatic reset" ID: 5947 22/21.1 SATEC: EM720/ EM720T - functionality 1 Detailed information regarding the content of the billing data record incorrect All billing data records of the EM720 were automatically assigned to the content type "Current values". This characteristic was changed. The billing data record is assigned to "Current values and resets" if current values and prevalues are read. If prevalues are separated from the record including the current values, the data records including the prevalues are assigned to the content type "Automatic reset" ID: 5948 22/5.3 Siemens: 7E (VDEW) Crash of ZFA-F V10.11 after reading 7E ZFA-F crashed at importing load profile data of a 7E container if the data of the first integration period were faulty. Processing number: 2014-000721 ID: 6182 22/8.4 SyM2 standard Reading of NTP parameters The NTP operating parameters could not be imported by an EMH SyM² communication module if single values were not parameterized. Now, the register record is imported without the affected values. Processing number: 2014-000437 ID: 5736 SyM² operating values with brackets cannot be imported The import failed if the meter supplied a register value which included brackets. Now, the bracket is replaced by a squared bracket. Processing number: 2014-000467 ID: 5746

107

ZFA-F device drivers gas 24/17.1 Datacon Electronic FWU800, FWU1600 Closed loop at the evaluation of incorrect data Incorrect data could cause a closed loop in the device driver FWU (Datacon) at the evaluation of load profile data for a billing data channel. A check for incorrect values in the load profile data was added to the device driver. Processing number: 2014-000565 ID: 5876 Prevalue records are not marked correctly by the Datacon driver All billing data records of the FWU (Datacon) were automatically assigned to the content type "Current values". This characteristic was changed. All generated billing data records are automatically assigned to the content type "Automatic reset" at the evaluation of load profile data for the billing data record. Processing number: 2014-000559 ID: 5833 24/2.2 Elster: DL240 Data are imported incorrectly If a DL240 device was read via GSM, it could happen that load profile data were assigned to the wrong channel due to a delay between sending and receiving the data. A verification which compares the requested channel number to the channel number of the received data was added. Processing number: 2013-001235; 2013-001478 ID: 5244 24/2.5 Elster: DL220 Reading of billing data did not work in the first month Billing data could not be imported if a DL220 was read during the first month of its installation. The reason was an empty month archive. The conversion has been adjusted. An empty month archive does not cause an error at the import anymore. Processing number: 2013-001586 ID: 4410 24/2.9 Elster: EK280 (IEC1107) Billing data are imported with 1 hour difference During the import, the time stamp of the billing data was interpreted incorrectly at the device drivers EK230, EK260 and EK280. The evaluation of the indicator for daylight saving time/standard time switch was improved in order to interpret the time correctly. Processing number: 2014-000415, 2014-000398 ID: 6070

108

24/7.2 Tritschler: K902/VC2 Scaling factor is not evaluated by ZFA-F At the evaluation of the load profile data of a VC2, the supplied scaling factor was not considered and had to be indicated manually by the user. Now, it is possible to start an automatic adjustment of the "General constants". To do this set the entry "AUTO_SCALE" at the conversion settings of the VC2, accessed via the web interface of the SCS, to „YES". ID: 3353 24/8.1 Wieser: MRG910 (DSfG) Load profile reading MRG910 does not consider last integration period The device drivers for MRG905 and MRG910 interpreted the indication for the daylight saving time/standard time switch incorrectly. Due to this the load profile could not be read up to the current time. The device drivers were adjusted and the time indications are interpreted correctly. Processing number: 2014-000660 ID: 5990 24/8.2 Wieser: MRG2200 Extension of the device driver MRG2200 by messages of device driver MRG2203 So far the device driver for the MRG2200 did not support the device-specific messages of an MRG2203. Now, all specific messages of the MRG2203 are supported by the device driver MRG2200. Processing number: 2014-000340 ID: 5867 OxCx system basis Medium gas at new installation of data channel The default energy type at the data channel of the device "DSFG-DFÜ" was "Electricity". Now, the default setting is "Gas". Processing number: 2014-000733 ID: 6181

109

ZFA-F device drivers different energy types 28/10.1 MUC standard OMS OBIS ID codes in ZFA-F for heat recording by means of MUC (inlet, return, spread) cannot be selected Load profile values of heat meters that are connected to MUC could not be imported. ID: 5961 70/2 Interface Kamstrup Network Engine Creating/Synchronizing more than 1000 devices at macro function "Synchronize Utilidriver" does not work Creating or synchronizing more than 1000 Utilidriver devices with the macro "Synchronize Utilidriver" did not work. Now, it is possible to synchronize or create more than 1000 devices with this macro. Processing number: 2014-000743 ID: 6215

110

Extensions/ new features/ changes in version 10.12 (Released on: 30/05/2014) New modules 22/1.13 Elster AS230 Integration device driver Elster AS230 (IEC1107) The device driver AS230 is released. Following actions are supported: Load profile reading, meter reading, requesting results, setting date/time and requesting date/time. ID: 1392 22/3.10 IskraEMECO: MT880 (DLMS) Device driver IskraEMECO: MT880 (DLMS) functionality 1 The device driver MT880 is released. ID: 3925 46/22.2.1 EMH: LZKJ/LZQJ (IEC1107) MES-F device driver for EMH: LZKJ/LZQJ (IEC1107) The device driver LZKJ/LZQJ for MES-F is released. ID: 3465 New released resources OxCx system basis Release of the Oracle 12c client The Oracle client 12c is released. Processing number: 2014-000542 ID: 5800 Release ZDUE-GPRS-SyM2 The communication module ZDUE-GPRS-SyM2 by Dr. Neuhaus is released. ID: 5153

111

Extended modules 16/0 Configurable export Extension of script language by optional parameters The script language was extended. Now you can indicate up to 9 parameters at the commands AND, FORMAT, OR and STRCAT. Now the indication of the last parameter at the commands MESSAGE, LIMIT, SET and STRFIND is optional. Now the command STRMID can determine the text up to the end of the character string. ID: 5055 22/1.8 Elster: Alpha / AS1440 Definable port at AM100 Now you can select the ports for the communication via DLMS and for the firmware update under "Communication mode" > "Specific" > "Port for DLMS" and "Port for firmware update". Processing number: 2014-000185 ID: 4970 22/16.2 EDMI: Mk7C Connect / Disconnect (load management) The actions "Disconnect" and "Connect" are now supported by the device driver MK7C. This functionality is supported by the MK10A from firmware version 1.465. ID: 2655 22/20.1 ITF/Reallin: E3010 Device driver ITF/Reallin E3010 (DLMS) functionality 1 additional ID codes The device driver E3010 could not read specific information from the device via the load profile. We created new ID codes with which you can read those additional pieces of information and display them in the billing data record. ID: 4674 22/20.2 ITF/Reallin E1000-03 Device driver ITF/Reallin E1000-3 (DLMS) functionality 3 additional ID codes The device driver E1000 could not read specific information from the device via the load profile. We created new ID codes with which you can read those additional pieces of information and display them in the billing data record. ID: 4673

112

29/0 Smart Communication Server (SCS) Output of the usage counter at network resources In addition to the name of the resource, a usage counter is added to the log files. This applies to resources which support a multiple use such as network cards and CISCO channels. ID: 4841 SCS: expected callback: Implementation in the communications service The callback with Enercom 400 is implemented in the SCS. ID: 2140 31/7 Administration of SIM cards Extend SIM card import to fixed IP addresses Additional master data can be imported to devices of the type "SIM card". ID: 2311 70/1 Interface Echelon NES Extension of billing data reading Extended request of additional energy and power registers. Processing number: 2014-000136 ID: 5206 70/2 Interface Kamstrup Network Engine Extension of Utilidriver macro to offer meter selection Added checkbox "Synchronize master data ". If the checkbox is activated, all meters of the target group are synchronized. If the checkbox deactivated, the meters are not synchronized. If you select an action, then this action is only executed for the meters of the target group. ID: 4755 88/1 Customized extension of the web service interface format 1 Customized web service interface MDM.Intf_03 Extension of the SOAP/COM API by the customized web service interface MDM.Intf_03 (set power contract). ID: 5064 Customized Web-service interface MDM.Query6 Extension of the SOAP/COM API by the customized web service interface MDM.Query6 (get current power limit) ID: 5062

113

97/2 Standard Web service interface Optional return of ID code names Now, the ID code names are exported optionally if register values are requested via the web service interface. ID: 5035 OxCx system basis Field "Data channel name" in the data view The new column "Data channel name" is available in the data view. Processing number: 2013-001648 ID: 4605 Loading configuration of the Monitoring Framework from central settings The configuration of the Monitoring Framework is read from the ZFA-F database and saved to the file "settingscache.xml" if the SOAP Instance manager is started. For this purpose a temporary embedded ZFA-F instance is started in order to establish a connection to the ZFA-F database. The ZFA-F user and the data base profile with which the ZFA-F instance is started have to be entered at the keys "USER" and "DATABASE_PROFILE_NAME" under section "DATABASE" in the file "simgr.ini". The default settings for those two values are USER = Administrator and DATABASE_PROFILE_NAME = STANDARD ID: 5543 Installation of Microsoft SQL Server 2008 R2 Native Client In addition to the database Microsoft SQL Server 2008 R2 Express Edition it is also possible now to install the Microsoft SQL Native Client. ID: 4448 New option at hour cycle "Synchronize execution times according to daylight saving time/standard time or standard time/daylight saving time" An additional option was added under: Options > Central > Automatic > General > SYNC_EVENTS_TO_DAYLIGHT_CHANGE. If this option is active, missing/additional hours are added or removed at the cycle calculation at the switching from standard time to daylight saving time and from daylight saving time to standard time. This characteristic is reproducible at schedules with cycles longer than one hour. Processing number: 2013-001422 ID: 4146

114

Modified modules 18/3 Priority control for communication and macros Setting the priority for manual requests The priority of manual actions can be set under ZFA-F option > Central > Manual action > Priority. Processing number: 2012-001046 ID: 833 Setting a priority at assigning schedules You can now set a priority in the schedule view. If you select a priority at creating a new schedule, all action groups assigned to this schedule will get this priority. Processing number: 2013-001599 ID: 3942 21/29.2 EDIFACT/MSCONS interface Edi@Energy Export The indication of a calorific value shall be optional at the export of energy values It is not necessary to assign a calorific value channel at the export of gas devices with energy values. Calorific value and volume correction factor are missing in the export file. Processing number: 2013-001649 ID: 4738 28/8.2 DSfG standard (DSfG) Reading of all disturbance meter counters at installation reading The changes concern devices which are read via the DSfG protocol. A total readout is executed if the action "Load profile reading" is started at an event-driven data channel and if you select "Device installation" as meter reading reason. ID: 5092 93/1 Standard interface for master data transfer ZFA-F Extend error message "At least one data channel type from the format file does not comply with the device template" by ID codes Now, the OBIS ID code of the affected data channels are logged if the error message "At least one data channel type from the format file does not match the device template" is returned. ID: 5178 OxCx system basis Different symbol for communication modules and SIM card in the tree structure Now, SIM cards and communication modules have individual symbols in the tree structure. ID: 5287

115

Extension of macro function "Delete" So far the macro function "Delete Device group" deleted all devices and device links that were selected. With the new combo box "Deletion type" you can define the deletion function more precisely. There are the options "Delete links" (only the selected device links are deleted) and "Delete devices" (the selected devices as well as the device links are deleted). So far the option "Delete device completely" was offered in a dialog at deleting device groups via the context menu in the tree structure of the device view. Now, the combo box "Deletion type" with the options "Delete links", "Delete devices" and "Delete devices globally" are offered. The option "Delete devices globally" corresponds to the option "Delete device completely" and replaces it. At this option, devices that are not included in the selected group are deleted (globally) as well. ID: 2238 Optimized indexes at very large table. Following indexes in the SQL scripts for creating a database structure at new customers were changed in order to improve the database performance. The following indexes were deleted: CREATE INDEX IND_LOG_VAL_FOR1 ON LOG_VAL (LOG_TRANS_ID) TABLESPACE INDEX_DATA; CREATE INDEX IND_PROFILEDATA_DATA_FROM ON PROFILEDATA (DATA_FROM, DATACHANNEL_ID) TABLESPACE INDEX_DATA; CREATE INDEX IND_PROFILEDATA_DATA_FROM2 ON PROFILEDATA (DATA_FROM, PSTATE, DATACHANNEL_ID, STATE) TABLESPACE INDEX_DATA; CREATE INDEX IND_RESULTDATA_DATA_FROM ON RESULTDATA (DATA_FROM, DATACHANNEL_ID) TABLESPACE INDEX_DATA; CREATE INDEX IND_RESULTDATA_DATA_FROM2 ON RESULTDATA (DATACHANNEL_ID, PSTATE, DATA_FROM) TABLESPACE INDEX_DATA; CREATE INDEX IND_PROFILEDATA_FOREIGN1 ON PROFILEDATA (DATACHANNEL_ID) TABLESPACE INDEX_DATA; Following indexes were added: CREATE INDEX IND_LOG_VAL_FOR8 ON LOG_VAL (LOG_TRANS_ID, CREATE_AT) TABLESPACE INDEX_DATA; CREATE INDEX IND_PROFILEDATA_DATA_FROM3 ON PROFILEDATA (DATACHANNEL_ID, DATA_FROM) TABLESPACE INDEX_DATA; CREATE INDEX IND_PROFILEDATA_DATA_FROM4 ON PROFILEDATA (DATACHANNEL_ID, DATA_FROM, STATE, PSTATE) TABLESPACE INDEX_DATA; CREATE INDEX IND_RESULTDATA_DATA_FROM3 ON RESULTDATA (DATACHANNEL_ID, DATA_FROM) TABLESPACE INDEX_DATA; CREATE INDEX IND_RESULTDATA_DATA_FROM4 ON RESULTDATA (DATACHANNEL_ID, DATA_FROM, PSTATE) TABLESPACE INDEX_DATA; Existing databases can also be adjusted by our consulting team if desired. ID: 1442

116

Errors fixed in this version Automatisms 30/17 Automatic generation of substitute values with reference values Incorrect logging of the messages of the macro function "Generation of substitute values" The macro function "Generation of substitute values" did not log a result. Now, the macro function logs the result of the function e.g. "Function OK." Processing number: 2014-000192 ID: 4992 32/2 Schedule - Execution status Incorrect execution of a schedule if communication profile was changed Changes in the device dialog of a device started the schedule which was assigned to the action group of the device. The execution of a schedule is not influenced anymore if a device is changed in the device dialog. Processing number: 2014-000203 ID: 5047 OxCx system basis The field SORT_NR must always be filled with "0" in ACTION_GROUP_ACTION_MODE_LNK in the device dialog. The column "Pos." of the table included in the section "Schedules" at the page "Action group" in the device dialog was removed. The value is always set to 0 since it has no control effect. ID: 4955 Calculations 24/2.9 Elster: EK280 (IEC1107) EK280 needs additional field for selecting password lock Up to now you could only use the administrator password at the EK280. Now, you can select the desired lock in the field "Password lock" and the entered password is interpreted correspondingly. Customers that have created EK280 devices with a version older than 10.12 need an update script. It can be provided by our support team. Processing number: 2014-000148 ID: 5529

117

30/11 Free definition and assignment of data channels Crash of ZFA-F at display of result data ZFA-F crashed if you had selected a data channel link whose source channel had a different day change. Now, the data channel link checks the day change of the source channels. If a source channel has a different day change, the data are not loaded and an error message is written to the log. Processing number: 2014-000051 ID: 5589 Incorrect export at balancing type: "Day, month and year balance" There were no data exported at the turn of the year if the balancing type "Day, month and year balance" was selected at a data channel link. Now, the data channel link is exported correctly at the turn of the year. Processing number: 2014-000395; 2014-000175 ID: 5590 30/18 Generation of substitute values by manual import of comparison measurements Manual generation of substitute values fails The generation of substitute values failed if you had assigned a different source device at the method "Copying" for generating substitute values. Now, the manual generation of substitute values works correctly even if you have selected a different source device. Processing number: 2014-000354 ID: 5639 31/6 Dynamic View Assigning a dynamic group at the script export is not possible The error at assigning dynamic groups to a script export was removed ID: 4935 OxCx system basis Status entries at event-driven load profile channels If there was a power failure concerning a measured value status at a physical load profile channel, the status "CN" was selected up to the first measured value for the event-driven load profile channel. Now, status "N" is only selected for the corresponding integration periods and the previous statuses remain unchanged. Processing number: 2014-000172 ID: 5390

118

Database interfaces 81/10 Standard interface for IS/E Incorrect meter reader notes and notices in the export file Incorrect meter reader notes and notices were supplied at some meters if order data were exported by means of the script "ise_xml_ct". The variables for notes or notices are now cleared at each process. Processing number: 2014-000503 ID: 5717 94/OxExtended database API for Oracle database Entry missing at script "drop_synonyms" Up to now the function call for deleting the synonym "dbi_datachannel_param_tim" was missing in the script "drop_synonyms.sql" which is part of the DB API package DBI_PROFILE. The corresponding function call was added to the script. Now, the synonym is deleted if the script is executed. ID: 5078 OxCx system basis Change installation via control panel > Programs and Functions > Change An error occurred at the installation of Crystal Reports during a change of an installation. Due to a wrong directory path, the required data could not be found. Now, the installation package of Crystal Reports is part of the setup.exe. Thereby, the path is set correctly and the change installation can be executed on success. Processing number: 2014-000313 ID: 5316 Database structure Missing index in table DBI_LOG_VAL at CREATE_AT The column CREATE_AT in the table DBI_LOG_VAL did not contain an index. This index was added. ID: 4812

119

Data import 21/R00 Raw data import Missing ID code conversion for gMUC Load profile data with the ID code 12.0.x for the type of energy "Heat" could not be converted and thus could not be assigned to data channels. Now, those data can be converted and assigned to data channels. Processing number: 2014-000405 ID: 5525 OxCx system basis Copying via "STRG+C" was not possible at Crystal Report Runtime After an update of Crystal Reports it was not possible anymore to copy texts via the shortcut Ctrl+C from the print preview to the clipboard. Now, this function is available again. ID: 5157 Data transmission 16/0 Configurable export Printing from data view not possible There was no database connection information saved for the ZFA-F database if an error occurred during the start of ZFA-F. Now, it is prevented that existing information from the INI file is replaced by wrong database connection information. Processing number: 2014-000349 ID: 5552 21/19.2 EDIFACT/MSCONS interface VDEW export Status conversion cannot be selected It was not obvious which status conversion was used for the MSCONS export of billing data. Now, the status conversion is displayed and can be adjusted. Processing number: 2014-000310 ID: 5296 21/29.2 EDIFACT/MSCONS interface Edi@Energy Export MSCONS problem after switch from standard time to daylight saving time The MSCONS export did not export any values via the state control if the assigned data channel link was event-driven and the integration period of the source channel was one day long. Now, the data are transferred without any gaps. Processing number: 2014-000348 ID: 5397

120

80/11 Standard interface for SAP IS-U Performance problem at the export with the script sapisu02.sct The script export caused performance problems if default data was accessed since the database was accessed at every request of default data. The information from table "DEV_GRP_DATACHANNEL_LNK_EXT" is saved to a buffer at the first access. Thus, further accesses to the database are avoided if the request of information from this table is repeated. Processing number: 2014-000316 ID: 5582 SAP-IS-U export (one header is created per device) The export SAP IS-U created several file headers per export file under certain conditions. Now, the method for determining whether a file header already exists works correctly. Processing number: 2014-000015 ID: 4648 iClient 60/x Internet module / iClient Incorrect schedule control Now, the schedule control works correctly. The customers or channels that were missing at the selection are now displayed. Processing number: 2013-001506 ID: 4252 iClient schedule control - empty billing data records at e-mail transmission via schedule Now, the e-mail transmission via schedule control works correctly. The .csv files contain billing data records. Processing number: 2014-000402 ID: 5557 No determination of the first and the last record at an SQL Server database (case sensitive) If the iClient was used with an SQL Server database (case sensitive) the buttons "First record" and "Last record" did not work. Now, the functionality can be used correctly after the error correction. ID: 5421 Message for session- timeout incorrect At the error message for a timeout, the error number or the error codes was included in this message. They are not part of the error message anymore. ID: 5249 Meter data balances are not displayed for month balance The month balance of a data channel link was not displayed at the iClient if the first day of the month did not contain any data (0C values). Now, the balances are displayed correctly. Processing number: 2014-000323 ID: 5396

121

Performance problem at data view via the iClient The determination of master data of a deeply nested load profile calculation caused performance problems at the iClient. Now, the physical source channels of the corresponding load profile calculation are not analyzed anymore at the load process. It avoids a useless recalculation of the values. Thus, the execution time is reduced significantly. Processing number: 2014-000324 ID: 5575 Unable to create schedules under Linux It was not possible to create schedules at the schedule control of the iClient under Linux. This error was removed. ID: 5241 Webportal/iClient and Heartbleed error An encoded communication could not be guaranteed to be secure anymore due to a security gap at the OpenSSL module. Now, the new open SSL version including the error correction is used. ID: 5540 Interfaces for MES-F 21/20.1 Standard interface for billing Import load profile via HHU import At devices with several profiles per load profile recorder only the first data channel was imported if the data channels were not specified explicitly at the handheld unit. Now, the data are imported completely provided that a data channel was specified for the corresponding profile in ZFA-F. Processing number: 2014-000482 ID: 5658 Devices and templates from the device pool are not exported without an order Devices and templates of the device pool were only exported if orders were exported as well. The order list may now be empty. ID: 5069 40/x Interface for mobile meter reading ( MES-F ) MES-F with time zone "GMT+2 Helsinki, Riga, Sofia" The selected system time zone was not set. Now, the system time zone is set correctly. Processing number: 2014-000553 ID: 5799 44/x HHU program MES-F The warning messages regarding the battery life are confusing The representation of warnings messages regarding a low battery was confusing. The display was improved. Processing number: 2014-000106 ID: 5227

122

44/x MES-F reading with defaults No reading available at new installation devices There was no reading available after the device selection was cancelled. Now, the reading can be started again. Processing number: 2014-000493 ID: 5697 44/x MES-F reading with without defaults Form processing: Fields cannot be addressed recursively Editing and refreshing fields which refer to each other did not work correctly. The method is corrected. Processing number: 2014-000401 ID: 5491 SCS 29/0 Smart Communication Server (SCS) Data of the control center cannot be changed The field is deactivated after the initial settings of the master control center were made. From this point of time you can only change the settings under SCS > System administration > Control center. ID: 3829 Communications service does not send results to the control center The communications service did not return any reading data to the control center if the corresponding process medium crashed. Now, it is restarted if necessary. ID: 4617 Control center crashes sporadically The control center crashed sporadically if reading data were accessed. Now, the access is thread-safe. Processing number: 2014-000144 ID: 5534 Deleting communication lines not possible Deleting SCS resources failed due to a database error. Now, deleting those resources is possible. Processing number: 2014-000149 ID: 4888

123

Master data transfer 93/1 Standard interface for master data transfer ZFA-F Synchronization of customer master data is not executed if the customer groups are interlaced. Creating a customer in an interlaced customer group caused an error message at the master data import. The customer is now created correctly. ID: 5128 System basis 26/9.1 ABB: F2 Raw data conversion MES-F device driver ABB F2 The conversion at the handheld failed at the reading of the F2 by ABB. Now, the raw data of the R2 are converted correctly at the handheld. Processing number: 2014-000214 ID: 5203 Raw data conversion MES-F device driver ABB F2 A conversion error occurred at reading the F2 by ABB by means of a handheld. Now, the raw data of the R2 are converted correctly at the handheld. Processing number: 2014-000214 ID: 5577 30/0 Tariff processing Incorrect identification color The color selected in the tariff list for the season could not be transferred anymore. Now, the color set correctly. Processing number: 2014-000309 ID: 5733 30/5.7 Plausibility check for variable time frames The MP8 check does not identify all date formats of the ID code 0.1.2 Only the value of the ID code "0.1.2" was considered at determining prevalues at resets. The value was ignored if its time stamp format was invalid. Now, the field "Time stamp" is checked as well at the determination of the ID code. Processing number: 2014-000218 ID: 5237

124

OxCx system basis Interruption of connection to Informix database The login to Informix databases did not work Processing number: 2014-000236 ID: 5117 Crash of ZFA-F if incorrect time frame is selected in profile data view The application crashed if a user-defined time frame for displaying profile data in the data view was defined in a way that the end time was before the start time. Now, the selection regarding the time frame is checked. An error message is returned if the selection is incorrect. ID: 4994 Automatic generation of substitute values in the load profile of a SYM²BM The different characteristics regarding the generation of substitute values were corrected. There may no method be available since "Module 30/19 Automatic generation of substitute values acc. to interpolation method" may not be used for counter value data channels. Processing number: 2014-000429 ID: 5591 Data change of a user causes change at customer assignment If the data of an existing user was changed in the view "individual", the assignment to a customer group was overwritten by the selection "all groups assigned". The customer groups defined in the view remain unchanged and are not overwritten anymore. Processing number: 2014-000365 ID: 5428 Documentation for the substitute value wizard - Direct comparison The explanations regarding the direct comparison were insufficient. The description has been extended and is now complete. Processing number: 2013-000402 ID: 2173 Edited value saved to wrong position If a value of the profile data was edited and saved, the edited value was shifted one hour to the past. This error only occurred if there was a time zone without daylight saving time selected at the data channel. An edited value of the profile data is now saved to the correct position. Processing number: 2014-000374 ID: 5425 Settings for profile design are not saved (Terminal server mode) The settings for the graphical representation in the data view were not saved in some cases. Incomplete options were deleted at loading the settings. Now, the settings are saved correctly and completely. Processing number: 2013-000115 ID: 1941

125

Reading the reading time frame of event-driven data channels The reading of interference channels was incomplete if the load profile reading was part of an action group with several actions war and a communication error occurred. In this case the end of data of interference channels is not set to the end of the reading anymore. ID: 5289 Error in the Logviewer The Logviewer created an INI file in a subdirectory each time a logf file was double-clicked. The INI-file is now saved to the correct directory, independent from the location of the log file. Processing number: 2014-000351 ID: 5376 Incorrect display of the toolbar "Edit" The toolbar "Edit" was displayed incompletely at the start of ZFA-F. Processing number: 2014-000357 ID: 5676 Error message "attempt xxx a free ID in table xxx " Unique IDs are required for saving database records to the database. Those are generated for all database tables via random numbers. At following tables conflicts occurred due to the large quantity of data records: - ACTION_EXEC_ATTEMPT - ACTION_EXEC_HISTORY - LOG_TRANS - LOG_VAL - PROFILEDATA - RESULTDATA In order to avoid those ID conflicts it is now possible to create the IDs via a subsequently installed stored procedure by means of sequences. In this case the range of values of the created IDs is: 1 to 2^63. Processing number: 2012-000905 ID: 1093 The field "Type of energy" is not filled in the order unit. Data channel information (e.g. the type of energy) and notes were only displayed in the order overview if address data were displayed. Notes and data channel information are now displayed if the corresponding column is displayed. Processing number: 2014-000198 ID: 5042 Device dialog: Saving the baud rate Only the standard communication mode could be edited in the device dialog at the page "Communication mode" under the section "Specific". Those fields are disabled at the alternative communication modes. ID: 5622

126

Limits at devices are determined incorrectly The verification of the limits "Maximum number of devices read by handhelds", "Maximum number of AMR devices" and "Maximum number of remote readable Smart Meter devices" was incorrect. Certain device types were excluded from the counting and the device hierarchy was considered. Processing number: 2013-000779 ID: 2552 INI synchronization at the installation So far the entry "Filename" in the section "LOG" of the zfa_f.ini was overwritten with the data of the user who was logged in and executed the installation. The entry is now saved correctly. Processing number: 2013-001392 ID: 4115 List of released resources has to be updated The list of released resources was incomplete. The Cisco Router ISR 39xx/29xx was missing. The missing resource was added to the list. The corresponding help is up to date. ID: 5761 Logviewer.INI causes problems at terminal server installation The path to the logviewer.ini was incorrect at the terminal server installation. The error was noticed at double-clicking a logf file. Now, the INI file is created at the directory "%APPDATA%". The last settings are restored correctly. Processing number: 2014-000290 ID: 4960 Message "Installation date older than 3 months" is output without changes in device view Under certain conditions the installation date was marked as "changed" in the device dialog even if though it was not changed. Processing number: 2014-000284 ID: 5344 Created communication server groups cannot be edited The name of the communication server groups could not be edited anymore. The reason was an error in the check whether the entry can be processed. Now, the check supplies the correct result and the names can be edited. Processing number: 2014-000295 ID: 5278 Performance improvement at using an Informix database The version of the timeseries loader was requested continuously even though the information was not needed. The useless request was removed. ID: 4907

127

Position change of ID codes leads to data loss If the positions of the conversion ID codes were interchanged in the conversion editor, then skipped ID codes were overwritten. Now, changing the position of the conversion ID codes with the shortcut "Ctrl + arrow key" works correctly. Processing number: 2014-000326 ID: 5337 Problem ZFA-F registration / user administration The fields "Last name" (login name) and "Number" were checked case sensitive if a system user was saved in the administration view. However, those fields have to be unique system-wide, independent from their case. Thus, conflicts with names at logging in to ZFA-F are avoided. ID: 4396 Connections of simgr.exe remain with CLOSE_WAIT Encoded TCP connections via a reverse proxy were not closed and remained in the state "CLOSE_WAIT". Due to this fact the iClient got very slow gradually. Now, the TCP connections are closed correctly. Processing number: 2014-000209 ID: 5122 Wrong translation of "Plausi_MP" in script export help The text "Plausi_MP" was translated to "Plausi_IP". This text may not be translated since it is a proper name. The text was corrected correspondingly. ID: 5139 ZFA-F rounds installation date to full minutes The memory button became active in the device dialog at devices at which the seconds of the installation date were unequal zero. The memory button does not become active anymore. Processing number: 2014-000201 ID: 5018 Display changes in the options dialog are not saved Changes concerning the display settings were not saved because the logic for saving was incomplete. The logic for saving was extended and now works correctly. Processing number: 2014-000264 ID: 5208

128

Web Service 96/0 Interface for collection of measuring data SIMGR and Heartbleed error OpenSSL was updated to version 1.0.1g due to the so called "Heartbleed" gap. The error is corrected. ID: 5537 Webportal 62/X Webportal Interface is not displayed if more than 50 data channels are assigned It was not possible to display more than 50 data channels at the Webportal. Now, it is possible. Processing number: 2014-000182 ID: 4980 ZFA-F device drivers electricity 22/11.1 LEM: EM4T/EM4T+ Problems at reading the 2nd frequency profile at the EM4T The error message "Load profile does not correspond to expected format" was returned at the import of the second channel of the frequency profile of an EM4T. If the profile contains the value "DC" it is imported as "1". ID: 5651 22/12.5 ELGAMA: EPQS (IEC1142) 100% CPU workload at reading The entry RECEIVE_DATA_DELAY in the file "eqps.ini" was increased in order to avoid the CPU load being too high. Processing number: 2014-000191 ID: 4986 Device ID with 7 digits - EPQS (IEC1142) Only 6 digits were transferred at sending the address to the EPQS This limit is removed. Now, it is possible to send a 12 digit address to the device. Processing number: 2014-000381 ID: 5518 Event log reading incomplete The event log data of the meter were not read completely under certain conditions. Processing number: 2014-000315 ID: 5334

129

22/15.3 Kamstrup: 382 J 382J supplies season flag incorrectly The meter does not supply a valid season flag. The season flag is not considered by the meter anymore. Processing number: 2014-000382 ID: 5630 22/16.2 EDMI: Mk7C Increasing data volume EDMI In the course of time the device driver MK7C caused a continuously increasing data volume. The increasing data volume was caused by the event log which was always read completely. Thus the meter gradually recorded more and more results. Now, an algorithm determines from which event log entry the reading is executed. The algorithm depends on the time frame of the action. Processing number: 2014-000202 ID: 5029 22/17.1 PRI: SprintXP Crash at reading messages with LBP protocol Unexpected characters at event log reading caused crash of the communication service. Correct handling of unexpected characters Processing number: 2014-000181 ID: 5091 22/21.1 SATEC: EM720/ EM720T - functionality 1 Missing event log entries Messages that were written due to a triggered setpointer were not evaluated at the device driver EM720. Now, all ID codes from table "F14 Setpoint Action ID" can be converted to messages. Processing number: 2014-000347 ID: 5489 Register 46116 is missing in the prevalue data records The device driver EM720 only generated data records without meter code at the separation of the prevalues. The ID code is also added to the separated data records if you add the ID code for the meter code to a register definition with prevalue reading. ID: 5564

130

22/5.4 Siemens/Landis & Gyr: ZMD/ZFD (VDEW) Reading action groups with date/time at the ZMD/ZFD VDEW The reading of date/time failed since the automatic change of the ID code did not work. If OBIS ID codes are entered at READ_DATE_ID and READ_TIME_ID without indicating a channel or the type of energy (e.g. 0.9.1), "1-1: is put in front at the change to fully qualified ID codes. Processing number: 2014-000325 ID: 5408 22/8.4 SyM2 standard SyM² imports negative values to A- If a SyM² meter supplied a counter value greater than 2147483647, the negative values were imported as load profile. Processing number: 2014-000549 ID: 5781 SyM² Load profile values imported prior to installation date at push operation After a failure of the power reserve, load profile values were possibly imported prior to the installation date at push operation. Processing number: 2014-000206 ID: 5197 ZFA-F device drivers gas 24/17.1 Datacon Electronic FWU800, FWU1600 Incorrect import at Datacon device The conversion was cancelled if there were characters in the billing data record of a FWU (Datacon) that did not correspond to the ASCII character set. This verification was removed. Thus it is possible to import billing data records which contain umlauts or similar characters. Processing number: 2014-000411 ID: 5519 24/2.2 Elster: DL240 Unhandled exception at import of load profile values A crash occurred at the import of load profile values at LIS200 devices. Now, the import of load profile values works correctly. Processing number: 2013-001281 ID: 3844

131

24/8.7 Wieser MRG905 (DSfG) Data regarding the switch from standard time to daylight saving time are imported incorrectly at the MRG905 and MRG910. Change of behavior at device driver for MRG905 and MRG910 Up to now the device drivers wrote a manufacturer-specific value to the container to indicate whether a switch from standard time to daylight saving time is executed. This caused problems at the last switch. The device driver was matched to the standard conversion for DSfG devices. ID: 5394 47/24.2.9 Elster: EK280 (IEC1107) Passwords EK280 Up to now you could only use the administrator password at the EK280. Now, you can select the desired lock in the field "Password lock" and the entered password is interpreted correspondingly. Processing number: 2014-000148 ID: 5228 ZFA-F device drivers different energy types 23/2.6 Görlitz: Skalar (IEC1107) Reading the meter "Scalar" via PPP/FTP via SCS does not work Up to now the meter "Scalar" by Görlitz could not be read via SCS with the protocol PPP/FTP. Now, the meter "Skalar" can be read via SCS with the protocol PPP/FTP. Processing number: 2013-000444; 2013-001021 ID: 2218 28/10.1 MUC standard Conversion of BCD-encoded values The billing data record with ID code 96.1.1 was imported with an incorrect conversion. Processing number: 2013-001637 ID: 5432

132

Extensions/ new features/ changes in version 10.11 (Released on: 04/03/2014) New modules 22/18.2 Schneider: ION7500/ION7550 (ION) Device driver for Schneider: ION7500/ION7550 (ION) New device driver for the ION7500 by Schneider Electric. Following actions are supported: Load profile reading, meter reading, requesting results, setting date/time and requesting date/time. ID: 2656 22/18.3 Schneider: ION8800 (ION) Device driver for Schneider: ION8800 (ION) New device driver for the ION8800 by Schneider Electric. Following actions are supported: Load profile reading, meter reading, requesting results, setting date/time and requesting date/time. ID: 3165 24/18.1 Emerson: Type 700 (Modbus) Device driver for Emerson: Modell 700 (Modbus) functionality 1 Added new device driver. Following actions are supported:

- Meter reading (single registers) - Read date/time - Set date/time

Processing number: 2012-001188 ID: 1021 70/5 Interface SAGEMCOM Enerscape SAGEMCOM Enerscape - Level 3 Enerscape integration level 3. Activate/deactivate actions ID: 2382

133

New released resources 00/00 New module P+E K01 USB optical probe under Win7 The USB optical probe K01 by P+E can be used with Windows 7 for a request. ID: 3580 Extended modules 21/26.2 EDIFACT/MSCONS interface Edi@Energy Export Supporting the Edifact versions MSCONS V2.2b, APERAK V2.1, CONTRL 1.3d and the OBIS ID code system 2.2b The MSCONS import and export supports the format 2.2b ID: 3849 24/17.1 Datacon Electronic FWU800, FWU1600 Saving the daily counter values to a billing data record Saving the daily counter values to a billing data record. Thus, the MSCONS export can export these counter values. ID: 4028 29/0 Smart Communication Server (SCS) Extension of the column sorting Now, the sorting to device number and property number at display of the IP-T slaves is possible as well. Processing number: 2014-000047 ID: 4679 60/x Internet module / iClient Deactivate e-mail jobs (without deleting them) E-mail jobs can be activated/deactivated ID: 1753 88/1 Customized extension of the web service interface format 1 Customized web service interfaceMDM.Intf_08 Extension of the SOAP/COM API by the customized web service interface MDM.Intf_08 (get status of action execution) ID: 4638

134

Customized web service interfaceMDM.Intf_02 Extension of the SOAP/COM API by the customized web service interface MDM.Intf_02 (open/close breaker) ID: 4636 97/2 Standard Web service interface Extension of the web service interface function "ChangeUserPassword" At the interface function "ChangeUserPassword" you always had to indicate explicitly whether the user logged in via the user number, the user name or the e-mail address. However, this information is not always available. For this reason, there is an additional attribute (login-name), at which the caller does not have to indicate the type of login but it is determined internally. ID: 4203 Support of alternative communication modes at ExecuteJob Now, the web service function "ExecuteJob" supports alternative communication modes. ID: 3278 OxCx system basis Automatic disposing at importing in the MES-F view For the automatic disposing of order units for die MES-F view, the generation of a temporary group has to be omitted. Therefor the option "Do not create subgroup" was added to the import. This option is available for the import types "IS/E format 1", "SAP IS-U format 1" and "Schleupen". Processing number: 2013-001030 ID: 3083 MES-F view: Make setting dialogs centrally available The MES-F-specific setting dialogs for "Meter reader notes", "Reading reason", "Templates for manual reading" and "Program Update" are now centrally available at the options dialog of the application. ID: 4664 Modified modules Informix: Import of profile data with the time series loader The time series loader is used at the import of profile data for a Informix database. ID: 4685 Reorganisation of the "MES-F setup" installation The file "mes_fsetup.exe" was moved from the folder "setupmes_fsetupin" to the folder "bin". The folder "setupmes_fsetupin" was removed completely. ID: 4102

135

Errors fixed in this version Administration for increased data security 15/3 Protection from accidental editing/deletion A newly created tariff season cannot be saved Now, the newly created tariff season can be saved again. Processing number: 2014-000049 ID: 4697 Multiple processing of protected devices Multiple processing for protected elements (protection from accidental editing/deletion) is now supported. Processing number: 2014-000010 ID: 4622 Automatisms 18/12 Alternative communication modes Switching at message number 100 does not work If a communication failed and the message number "100" was output, only the first alternative communication mode was considered. All further communication modes were not considered. Processing number: 2013-001627 ID: 5021 Calculations 30/11 Free definition and assignment of data channels At a multiple import of data (MSCONS import) to a DCA an assert was output. The import was cancelled at a multiple import without leaving the import mask to a data channel alias with a day change at 6 o'clock. Processing number: 2013-001451 ID: 4671 Incorrect display of profile data balances At hierarchic evaluations, e. g. data channel link over a load profile calculation, the data were not displayed correctly in the table of the data view. Now, the data are displayed correctly. Processing number: 2013-000936; 2013-001429 ID: 2917

136

31/1 Master data wizard The data channel type (S0 event-driven) is not transferred correctly at he master data wizard At the meter installation via the master data wizard, the source channels of the type "S0 (event-driven)" are connected to a metering point via a data channel link. The data channel link, by mistake, was created as type "S0". Now, the data channel type is matched correctly according to the source channel at creating a data channel link. Processing number: 2014-000107 ID: 4794 31/6 Dynamic View ZFA-F crashes if the dynamic view is opened An error occurred at the processing of SQL statements if the dynamic view was opened. The dynamic view was matched to the special characteristics of the Informix database. Thus, the view is available again. Processing number: 2013-001440 ID: 4463 Database interfaces 91/1 Interface for component-based access The interface function "RenewPassword" does not consider the fields "Subject" and "Message" at sending e-mails. The fields "Subject" and "Message" were always replaced by a standard text in the country-specific language. Now, you can pre-configure those fields with own texts at the corresponding macro function. ID: 4509 94/OxExtended database API for Oracle database Extension of the help for the update of shared time series database The help was extended by the note that an update of the common data pool may only be executed after consultation with ITF-EDV. Processing number: 2013-000516 ID: 2302 Value error at DBI_RESULT.EVALUATE_OBIS_ID The range of values for the device information(t_recDeviceinformation) regarding the OBIS-ID codes 0.0.x was extended from 20 to 50 in the specification for the DB API Package DBI_RESULT. ID: 4162

137

Data transmission 21/10 Data transfer via laptop Error at opening the Sybase archive database Now, you can open the Sybase archive database even if ZFA-F was started with the ZFA-F Sybase database. Processing number: 2014-000077 ID: 4804 21/19.1 EDIFACT/MSCONS interface VDEW import Error at import of the calorific value at a higher time frame The import of a calorific value with ID code 54.0.22 was not possible. Processing number: 2013-001619 ID: 4618 21/19.2 EDIFACT/MSCONS interface VDEW export EDIFACT-MSCONS 2.2a exports incomplete days It was not possible to export only complete days at the MSCONS version 2.2a. Processing number: 2013-001596 ID: 4507 21/21 State control for EDIFACT-MSCONS export Incorrect function of the state control at active plausibility check If the export started with a plausibility error between 0 o'clock and day change (6 o'clock), then this time frame was not considered and the data were exported from the time of the day change. Processing number: 2013-001082 ID: 3337 21/26.2 EDIFACT/MSCONS interface Edi@Energy Export DCA displays counter values incorrectly at the selection of a free time frame which did not exceed one day. Incorrect counter values were supplied if a free time frame with beginning and end on the same day was requested at a data channel link. Now, the data channel link supplies correct values even if a free time frame which does not exceed one day is requested. ID: 4563

138

21/29.2 EDIFACT/MSCONS interface Edi@Energy Export Incorrect MSCONS export at status conversion The export was cancelled if a status could not be converted due to an incomplete status conversion. Now, the export is executed up to the fault position and then it is continued with the next data channel. Processing number: 2014-000038 ID: 4693 40/x Interface for mobile meter reading ( MES-F ) Wrong meter reader is exported Now, the meter reader is read from the table "SERVICE" Processing number: 2013-001462 ID: 4381 iClient 60/x Internet module / iClient Update installation wizard for the iClient Due to adjustments on the installation wizard, the configuration file has to be created again at the update to version 10.11. For starting the installation wizard, the current config.php file has to be deleted from the iClient directory or, even better, has to be renamed temporarily (thus, you can look up the old settings if necessary). ID: 4938 Wrong units are displayed at the iClient The path for Unit.ini file included backslashes. These were replaced by slashes. Thus, the file is loaded correctly under Linux as well. Processing number: 2014-000009 ID: 4763 Customized interfaces 88/1 Customized extension of the web service interface format 1 MDM.Query5: Marking or deleting of inactive connections between device and metering point Now, inactive devices are not considered anymore at the assignment from device to metering point in Query5. ID: 4588

139

88/2 Metering data import format 1 Error at import of billing data Assignment of the ID codes at the billing data record improved. ID: 4864 Interfaces for MES-F 44/41.X MES-F data transmission for handheld program MES-F installation does not start on handheld units of the type HP 2790b Now, the MES-F installation can be started from handheld units of the type HP 2790b as well. Processing number: 2014-000120 ID: 4887 44/x HHU program MES-F Scanner for MC70 and MC50 does not work Now, the handheld unit names for the scanner support are not case sensitive anymore. ID: 4902 44/x MES-F Module for barcode reading Barcode reading PPT8800 not possible Now, the handheld "PPT8800" is configured correctly for using the scanner. Processing number: 2013-001576 ID: 4375 SCS 29/0 Smart Communication Server (SCS) Switch of CC standby to CC master and automatic operation The switching process from master control centers to standby control centers was revised fundamentally so that automatic clients can continue their operation with full functionality after a switch. ID: 4263 Control center crashes The control center crashed sometimes if it was closed. Processing number: 2014-000161 ID: 4913 Login on SCS is not possible if the password begins with space characters Now, passwords with space characters at the beginning are possible. Processing number: 2014-000119 ID: 4817

140

An "empty" slave name is used at the login to an external switching center An "empty" slave name is used at the login to an external switching center. Now, the slave names are filled correctly. Processing number: 2014-000002 ID: 4632 Missing values in the field communication server of the action history Now, the field "Communication server" in the action history is filled even if you select the option "Optional" under "Communication server" at an SCS reading. Processing number: 2013-001334 ID: 3964 Error messages at php.log The codes which caused the warnings or notes in the PHP log file were adjusted correspondingly. Processing number: 2014-000004 ID: 4647 Help of the IP-T master unavailable Now, the help for the IP-T-master is displayed correctly again. Processing number: 2013-001327 ID: 3976 Communication statistics is not recorded at the communication mode TCPIP Now, the communication statistics is recorded at the transmission via TCP/IP as well and can be viewed at the data container under the section <STATISTICS_L20>. Processing number: 2013-001542 ID: 4320 Control center blocks the communication resource after fatal error The resource was blocked if the parsing of the file that was read failed. Processing number: 2014-000167 ID: 4914 Control center crashes sporadically The concurrency of the control center was optimized. ID: 4629 Control center crashes sporadically Adjusting the object lists in the settingscache.xml during a master data update could possibly cause a crash of the control center. Processing number: 2013-001530 ID: 4733 Control center started multiple times via services If at least one IP-T master was not available, it could take more than one minute to exit the service. ID: 4649

141

Parsing error at display of the communication protocol PPP The format error in the communications log that was caused by a quotation mark was removed by correcting the JSON-string. Processing number: 2013-001408; 2013-001524 ID: 4271 System basis OxCx system basis Crash in moving devices Saving edited values in the data view could lead a cancellation of the application. The corresponding spot was corrected. Processing number: 2013-001400 ID: 4266 Crash in the customer dialog if an invalid mail address was used If there was an invalid e-mail address in the master data, then loading this customer caused a crash of the application. Now, the validation of the e-mail address and loading the master data works correctly. Processing number: 2014-000079 ID: 4756 Selection arrow for new views missing After starting the program or resetting the views, the arrows for selecting specific entries were not displayed in the toolbar anymore. Processing number: 2014-000178 ID: 4990 Automatic clients remains Optimization of the automatic, operation is continued at network disturbances as well. ID: 2692 Automatic registration PrintSvr.dll Always use a .Net Framework version higher than 1 at registering the "printsvr.dll" to prevent the registration to be cancelled. Processing number: 2013-001469 ID: 4205 At error in moving devices the assigned devices are not moved with it. At moving devices to which other devices are assigned, only the first assigned device was considered. This restriction was removed. Processing number: 2013-000016 ID: 4540

142

Buttons disappear sporadically After correcting the toolbar, the bitmaps of the toolbar icons were dislocated since old settings were saved in the registry by the MFC Framework Views, toolbars and menus are reset automatically at the first start of ZFA-F. Following entry is created in the ZFA_FS.INI: [MAINFRAME] INITIAL_VIEW_RESET=VAL(FALSE); The entry prevents an automatic reset at the next start. The following actions in the INI file causes an automatic reset again: - Setting the entry to TRUE - Delete the entry - Delete the ZFA_FS.INI ID: 885 Database fields Appserver - Informix database There were TSL_Flush errors at the Appserver in the Informix database. Importing was not possible after the errors occurred. Processing number: 2014-000159 ID: 4971 Basic load profile calculation supplies error "invalid argument was encountered" The number of source channels was restricted to 50. The formula checks whether a non-existing Cx variable was entered. e.g. all values >C50 are invalid The formula check was extended: If you enter variables of the type X, L or F in the formula, they will be determined to be invalid since the formula may only include variables of type C. Processing number: 2013-000637 ID: 2629 E-mail is not moved (e-mail received (IMAP)) A buffer error occurred at the processing of e-mails with IMAP if there was no message text and the e-mail appendix exceeded the buffer size. For this reason, the received e-mail appendix could not be moved to the destination directory. The error is corrected. The size of the e-mail message text is limited to 256 KB. The remaining character string is cut off. The size of the e-mail appendix is not limited. Processing number: 2013-000942 ID: 4715 An update installation supplies an error message at the start of the INI synchronization. The synchronization is not executed correctly. Now, the INI file synchronization is executed correctly. Thus, the error "side-by-side configuration is incorrect" does not occur anymore. Processing number: 2013-001629 ID: 4789

143

Error in schedule overview Schedules which are in the future and which have to be executed only once are displayed in the schedule overview. Schedules which are in the future and which have to executed cyclically are displayed in the schedule overview from their first execution. Processing number: 2012-001484 ID: 1428 Incorrect schedule realization at DST/ST switch At DST/ST switch the execution time was calculated incorrect. The error occurred if the meter was unavailable and an alternate schedule was calculated. If the calculated alternate schedule was in the duplicate hour 2:00-3:00 o'clock at the switch from daylight saving time to standard time, the software calculated incorrect schedules from that point on. This error is corrected. Processing number: 2013-001420 ID: 4399 Remote device disconnected at leased line reading If meters were read via a general communication module in leased line mode, the communication was cancelled with the error message "Remote device disconnected". ID: 4642 Device cannot be deleted If, at a change order, the device to be installed/removed is moved, both devices are moved. Processing number: 2013-001617, 2014-000039 ID: 4500 Incorrect time stamp (setup.exe) The modification date of files in the ZFA-F installation packages is now correct. Processing number: 2014-000115 ID: 4811 Interruption test: Orders of the alternative communication server are not imported Orders which were processed via an alternative communication mode are imported even if the communication system of the used communication mode does not correspond to the standard communication mode. ID: 4258 Parent-Child: The communication mode of the meter is displayed in the meter but not the communication mode of the modem. If a device is assigned to a parent device, the page "Communication mode" has changed as follows: Now, the sections "General" and "Settings" are collapsible and the data of the standard communication mode of the parent device are displayed. These data cannot be changed. Furthermore, the selection list "Communication mode" was removed. ID: 4238 Password of the print database is not read from INI at the printing profile <no> . If the printing profile "<no>" is used at the export reading statistics, the database login information is not loaded correctly. Processing number: 2014-000179 ID: 4950

144

Saving new action groups failed The memory button does not become active anymore. Processing number: 2014-000147 ID: 4956 Update installation: Changed start parameter of service are lost At an update from a 32bit version (from version 10.10) or from 64bit (from version 10.6) to version 10.11, the settings remain unchanged. In case SCS is already installed, the dialog "SCS Ports" is not displayed anymore. ID: 4274 Webportal 62/X Web portal No function of the PDF print function Now, the PDF export function works with all currently released browsers Processing number: 2013-001653 ID: 4612 ZFA-F device drivers electricity 22/16.2 EDMI: Mk7C The completeness of the logical name is only checked by means of an assert. At a request of DLMS devices it was assumed that the logical name of the device is always supplied correctly. An assert occurred if this was not the case. This characteristic was changed. Now, the logical name of the object is checked. Processing number: 2013-001357 ID: 4580 22/20.1 ITF/Reallin: E3010 E3010: Sorting of time stamp for prevalues incorrect After the 4th reset of an E3010 the prevalues were not displayed with the correct time stamp anymore. The error is corrected. ID: 4771 Error message if no prevalues exist in the meter The reading of the prevalues was cancelled if the E3010 had not reached the maximum number of prevalues. The reason were unreadable objects in the device. The driver was adapted and only reads the maximum number of existing objects from the meter. ID: 4138

145

Integration period difference causes data gap It is possible that an E3010 supplies time stamps for load profile values which are not within the period. The reason are seconds which are supplied by the meter. Due to the difference from the integration period, the values were summed up in ZFA-F. After consultation with the manufacturer, the seconds supplied in the time stamp are not considered at the load profile evaluation. Processing number: 2013-001477 ID: 4249 22/20.2 ITF/Reallin E1000-03 E1000-03: Sorting of time stamp for prevalues incorrect After the 12th reset of an E1000 the prevalues were not displayed with the correct time stamp anymore. The error is corrected. ID: 4772 Error message if no prevalues exist in the meter The reading of the prevalues was cancelled if the E1000 had not reached the maximum number of prevalues. The reason were unreadable objects in the device. The driver was adapted and only reads the maximum number of existing objects from the meter. ID: 4137 Integration period difference causes data gap It is possible that an E1000 supplies time stamps for load profile values which are not within the period. The reason are seconds which are supplied by the meter. Due to the difference from the integration period, the values were summed up in ZFA-F. After consultation with the manufacturer, the seconds supplied in the time stamp are not considered at the load profile evaluation. Processing number: 2013-001476 ID: 4250 22/3.3 IskraEMECO: ME372/MT372 - functionality 2 Incorrect protocol flow at reading via PPP/web service Incorrect protocol flow at reading via PPP/web service improved. Processing number: 2014-000062 ID: 4770 22/8.4 SyM2 standard Device driver SyM² stores push load profile data to the wrong device The data were imported incorrectly if the push data contained load profile data of two different meters. Processing number: 2014-000132 ID: 4852

146

23/3.1 IskraEMECO: P 2S P2 meter causes problems at the export to MES_F Meters with a blank "MeterDeviceType.KeyName" are imported correctly to MES-F, now. Processing number: 2014-000145 ID: 4868 70/1.10 Device driver Echelon EM1020 Readings via SCS does not work with the ANSIC12 protocol The communication settings at the SCS were missing for requesting the EM1020 via the protocol ANSI C12 at the IR interface. That is why the request failed. ID: 4801 ZFA-F device drivers gas 24/20.1 Flonidan Uniflo 1200 (IEC 1107) The conversion is cancelled if the load profile counter values have a different length. At an evaluation of the load profile data of an Uniflo1200, it was checked whether the length of a record corresponded to the previous record. The conversion was cancelled if this was not the case. The verification was removed. Processing number: 2014-000021 ID: 4698 24/3.1 FLOW COMP: gas-net Z0 Incorrect symbol at the GNETZ0 causes fatal error at control center The SCS control center possibly crashed if invalid characters were received at the request of meter master data. Now, the device driver checks whether the characters are valid. Processing number: 2014-000144 ID: 4918 24/9.3 RMG: ERZ 2200 Incorrect import due to CRC-Check The CRC start value of the corrector instance was read for the load profile request. The import of data failed if this value was not parameterized according to the registration instance. Processing number: 2013-001313 ID: 4777 Device ID at LP request is missing (all device drivers with DSfG protocol) The PP1 master data check did not work at all DSfG devices. Now, the device ID is additionally requested at the load profile reading. The device ID is always checked if the PP1 check is active. ID: 3988

147

ZFA-F device drivers different energy types 23/2.3 Görlitz: ENERCOM400(E/G) Multibox reading: Import of several load profile channels failed If two load profile channels were requested by the Multibox, the second channel was not imported. Processing number: 2014-000083 ID: 4720 28/8.1 GPS receiver standard Error at raw data import of the geo data from the Railwaybox At the end of a data record, the data are only imported up to the last complete integration period (set in ZFA-F). Values of integration periods (of the GPS receiver), which are not within the ZFA-F integration period are deleted. Processing number: 2013-000776 ID: 4865

148

Please find further information under: Customer Login, released versions

www.itf-edv.de Walderbach, 24/11/2015 ITF-EDV Fröschl GmbH