PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 1/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year Revision M. Obritzhauser 21 03 12 B Switch Mode Power Supply Product Name: E2xFxWx 12W PS EuPII Input: 100 - 240 V AC Output : 5V – 24V max. 12W max. 1,5A Type: E2xFxWx 12W PS EuPII

E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

1/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

Switch Mode Power Supply Product Name:

E2xFxWx 12W PS EuPII

Input: 100 - 240 V AC

Output : 5V – 24V

max. 12W

max. 1,5A

Type: E2xFxWx 12W PS EuPII

helkun
Rechteck 1:3
helkun
gross, schmal
helkun
quadrat
Page 2: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

2/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

1.1 Evolution ...............................................................................................................3

2 Scope ............................................................................................................................3

3 Technical Specification Sheet...................................................................................4

3.1 Input Specification .............................................................................................4

3.2 Safety and Environmental Conditions ............................................................4

3.3 Output Specification..........................................................................................5

3.3.1 Output template.....................................................................................6

3.3.1.1 Standard power supply................................................................6 3.3.1.2 With current regulation option (optional ordering)...................7

3.4 Mechanical Parameters....................................................................................8

4 Housing Dimensions.....................................................................................................8

4.1.1 Housing 12

5 Marking on the housing........................................................................................... 12

5.1 Laser marking ................................................................................................... 12

6 EMC............................................................................................................................. 13

6.1 Emission with representative device: ........................................................... 13

6.2 Immunity To Flicker........................................................................................... 13

6.3 Immunity to Fast Transients (Burst)................................................................. 13

6.4 Immunity to Radiated Electromagnetic Field ............................................ 13

6.5 Immunity to Electrostatic Discharge ............................................................ 13

6.6 Surge Capability .............................................................................................. 13

6.7 Immunity to conducted disturbances ......................................................... 13

6.8 Immunity to voltage dips, short interruptions and voltage variations.... 14

7 Reliability .................................................................................................................... 15

7.1 MTBF 15

7.2 Maintainability.................................................................................................. 15

7.3 Temperature cycle test .................................................................................. 15

8 Safety.......................................................................................................................... 16

8.1 Dielectric Strength ........................................................................................... 16

8.2 Over-current Protection ................................................................................. 16

8.3 Single Component Failure.............................................................................. 16

8.4 Short Circuit....................................................................................................... 16

9 Approvals and test standards ................................................................................ 17

9.1 General ............................................................................................................. 17

9.2 Test Standards .................................................................................................. 17

General EMC standards .............................................................................. 17

Information technology equipment.......................................................... 17

Household devices 17

Medical electrical equipment ................................................................... 17

9.3 Approvals .......................................................................................................... 18

10 Ordering Information ............................................................................................... 20

11 Packaging and weight............................................................................................ 21

Page 3: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

3/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

1.1 Evolution

Edition Date Responsible Reason of change

A 14.12.2011 Mauritz First edition

B 21.03.2012 Mauritz Enclosure leakage current

added

2 SCOPE

This document describes a switch mode power supply unit (AC/DC converter)

with fixed output voltage.

The unit is designed as a Wall Plug In; PCB mounting module or desk top power

supply.

Page 4: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

4/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

3 TECHNICAL SPECIFICATION SHEET

3.1 Input Specification

Parameter Key Min Typ. MaxUnit Test Cond.

Input Voltage UIN 90 264V AC

Input Current IIN 3 110 300mA

Input Frequency fIN 47 50 63Hz

80 % At full load

Efficiency η

According EuP Tier II

Switching Frequency fsw 65 kHz

300mW Without

load

Stand-by power P stb

According EuP Tier II

Input Voltage

If the input voltage is out of operating range, the power supply does not meet

the full specification. Above the specified upper limit of the input voltage the

unit can get damaged. Below the specified lower limit of the input voltage the

unit does not meet the specification.

Efficiency Under Load

The efficiency is defined as the ratio between the output power and input

power.

3.2 Safety and Environmental Conditions

Parameter Key Min Typ. Max Unit Test Cond.

Dielectric Strength 3 KVAC Standard

3 KVAC Household

4 KVAC Medical

Enclosure leakage

current according EN

60601

100 µA Medical

Operating Temperature 0 40 °C

At free

convection

32 104 °F

Storage Temperature -30 25 80 °C

-22 77 176 °F

Humidity 95 %

Page 5: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

5/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

3.3 Output Specification

Parameter Key Min Typ. Max Unit Test Cond.

Output Voltage U2 5 24 V 0 – 1,5A

Output voltage

tolerance TU2 3 % at PCB

Output Current I2 Nominal 1,5 A

Max. Overload

current I2 Overload

180

150

% of I2

Nominal

UIN = 264V

UIN = 90V

Output Power P2 12 W

Ripple Voltage U2,rms 50 mVrms

Output voltage tolerance

at end of EGSTON

standard cable

1,5m/0,5mm2

∆U2

+3/-10

+3/-5

%

at 5-12,9V

at 13-24V

The unit is not long time over-current proof. If the unit is powered longer than 1

min in overload conditions (current range between I2 Nominal and I2 Overload ), the

device can be damaged. The period between two overload conditions has to

be at least 15 minutes.

Page 6: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

6/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

3.3.1 Output template

3.3.1.1 Standard power supply

OverloadCurrent

Overload Area

Nominal

Foldback

Voltage

Specified Area

Specified area:

At an output current from 0A to I2 Nominal the unit fulfills all specified data.

Overload area:

At an output current from I2 Nominal to I2 Overload the power supply delivers the

specified output voltage U2.

The unit is not long time overload proof. If the unit is powered longer than 1 min

in overload conditions, the device can be damaged. The period between two

overload conditions has to be at least 15 minutes.

Fold back area:

If the power demand would be greater than I2 Overload or the power supply

works in short circuit the output voltage and current can not be defined (this

parameters are not stable). The wattage of the SMPS is de-rated. In this mode

the unit can not be damaged. After removing this conditions the unit fulfills the

specification.

Page 7: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

7/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

3.3.1.2 With current regulation option (optional ordering)

Constant Voltage

NominalCurrent

Voltage

Specified Area

Constant Current

Constant voltage area:

At an output current from 0A to I2 Nominal the output voltage is constant.

Constant current area:

If the load on the output increases at the point I2 Nominal the output voltage

drops down, depending on load. The power supply delivers a constant current.

Current limit can be adjusted according customer requirements.

Page 8: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

8/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

3.4 Mechanical Parameters

4 HOUSING DIMENSIONS

Euro Housing:

Page 9: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

9/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

US Housing:

UK Housing:

Page 10: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

10/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

Desktop Housing with IEC 320 C14 primary plug:

Desktop Housing with IEC 320 C8 primary plug:

Page 11: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

11/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

Changeable plug Housing:

EU Plug according: EN50075 US Plug according: UL1310 UK Plug according: BS1363

Australia Plug according: AS/NZS 3112

Page 12: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

12/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

4.1.1 Housing

Housing Material PA or PBT Colour of Housing black

5 MARKING ON THE HOUSING

5.1 Laser marking

Product name

Input parameters

Output parameters

Safety instructions

Date code of production

CE marking

Approval marks

Page 13: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

13/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

6 EMC

The units meet the following EMC requirements:

6.1 Emission with representative device:

Test passed according to EN55022 Class B and FCC15 Class B.

6.2 Immunity To Flicker

Test according to EN 61000-3-2

6.3 Immunity to Fast Transients (Burst)

Test according to EN61000-4-4

Input Line: 2.0kV – 5/50 ns – 5.0 kHz

Output Line: 2.0kV – 5/50 ns – 5.0 kHz

6.4 Immunity to Radiated Electromagnetic Field

Test according to EN 61000-4-3

Test characteristic: 80 – 1000 MHz; 80% AM (1kHz), 3V/m

6.5 Immunity to Electrostatic Discharge

Test according to EN 61000-4-2

Test characteristic: Contact discharge 6kV

Air discharge 8kV

6.6 Surge Capability

Test according to EN61000-4-5

Test characteristic: line to line: 1kV Surge

line to earth: 2kV Surge

6.7 Immunity to conducted disturbances

Test according to EN 61000-4-6

Test characteristic: 150kHz – 80 MHz; 80% AM (1kHz), 3V

Page 14: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

14/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

6.8 Immunity to voltage dips, short interruptions and voltage

variations

Test according to EN 61000-4-11

Test criterion C

Page 15: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

15/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

7 RELIABILITY

7.1 MTBF

For the calculation the following standards was used:

MIL-HDBK-217 F

MTBF at 25° ambient temperature:

5.681.818h

MTBF at 40° ambient temperature:

2.604.167h

7.2 Maintainability

The power supply is not to be repaired.

7.3 Temperature cycle test

During quality approval the unit passed the EGSTON standard temperature

cycle test.

Page 16: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

16/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

8 SAFETY

The units pass the following tests:

8.1 Dielectric Strength

The input isolation test voltage is

3kV 50/60 Hz for standard and household applications / 4KV 50/60Hz for

medical application , sinusoidal waveform.

Test duration is 2 seconds for 100% test, 1minute for lot-test.

8.2 Over-current Protection

The unit is not long time over-current proof. If the unit is powered longer than 1

min in overload conditions, the device can be damaged. The period between

two overload conditions has to be at least 15 minutes.

8.3 Single Component Failure

A single component failure does not cause any damage to persons or ambient

(fire, explosions, etc).

8.4 Short Circuit

The power supply is designed with a short circuit protection. A shortened

output does not cause any damage to persons or ambient (fire, explosions,

etc.) After removing this conditions the unit fulfills the specification.

Page 17: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

17/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

9 APPROVALS AND TEST STANDARDS

9.1 General

The device is galvanically isolated with safety extra low voltage (SELV) output.

9.2 Test Standards

EN 55014-1 EN 55014-2 EN 55022 EN 55024 EN 60601-1-2 EN 55011

General EMC standards

EN 60950-1 UL 60950-1

Information technology equipment

EN 60335-1 EN 61558-2-16 UL 60950-1

Household devices

EN60601-1 EN 61558-2-16 UL 60601-1

Medical electrical equipment

Page 18: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

18/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

9.3 Approvals

Approvals Housing Information

technology equipment

Household

devices

Medical

electrical equipment

EU, UK:

US, Canada:

Desktop

Australian

Gouvernment

approval

Australian

Gouvernment

approval

Australian

Gouvernment

approval

Australia:

Australian

Gouvernment

approval

Australian

Gouvernment

approval

Australian

Gouvernment

approval

Changeable

plug:

Australian

Gouvernment

approval

Australian

Gouvernment

approval

Australian

Gouvernment

approval

Page 19: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

19/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

C/US NRTL approval issued by Curtis Straus

ENEC

Conformity with the EU low voltage directive and EMC directive

Page 20: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

20/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

10 ORDERING INFORMATION

Voltage Tolerance:

3 3% on PCB

1 1% on PCB

Application Area:

S Information Technology

H Household

M Medical electrical device

Housing:

E Euro Plug-In

U US, Canada Plug-In

G United Kingdom Plug-In

A Australia Plug-In

C Changeable Plug

D Desktop

S Cable-Cable

P PCB Module

O Open Frame

E 2 _ F _ W _ _ _ _ _

Options:

L Power On LED

C Current Regulation

F Functional Earth

W Waterproof

Page 21: E2xFxWx 12W PS EuPII 12W.pdf · PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII Page 2/21 Document prepared and responsible for M. Mauritz Standard Programme Approved by Day Month Year

PRODUCT SPECIFICATION E2xFxWx 12W PS EuPII

Page

21/21 Document prepared and responsible for

M. Mauritz Standard Programme Approved by Day Month Year Revision

M. Obritzhauser 21 03 12 B

11 PACKAGING AND WEIGHT

E2EFSW3 12W

pcs kg size

Single Carton 1 0,16 125x67x44

Power Supply per Packaging Case 50 8 371x266x242

Power Supply per Layer (EU- Pallet) 9 Packaging cases

450 93 1200x800x242

1 Full Pallet (6 Layer) 2700 453 1200x800x1500

E2GFSW3 12W

pcs kg size

Single Carton 1 0,18 135x74x49

Power Supply per Packaging Case 50 9 406x286x272

Power Supply per Layer (EU- Pallet) 8 Packaging cases

400 93 1200x800x272

1 Full Pallet (5 Layer) 2000 360 1200x800x1500

E2UFSW3 12W

pcs kg size

Single Carton 1 0,16 125x67x44

Power Supply per Packaging Case 50 8 371x266x242

Power Supply per Layer (EU- Pallet) 9 Packaging cases

450 93 1200x800x242

1 Full Pallet (6 Layer) 2700 453 1200x800x1500

E2CFSW3 12W

pcs kg size

Single Carton (including Power Supply and 4 Adapters) 1 0,24 210x74x50

Power Supply per Packaging Case 25 6 406x286x272

Power Supply per Layer (EU- Pallet) 8 Packaging cases

200 69 1200x800x272