48
IBM Systems © Copyright IBM Corporation 2016 Peter Kimmel ATS System Storage EMEA ESCC Rhein-Main Enterprise Storage Solutions 2016-11-30 DS8880 R8.2 & Flash DACH User Group Meeting

DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems© Copyright IBM Corporation 2016

Peter Kimmel

ATS System Storage EMEA – ESCC Rhein-Main

Enterprise Storage Solutions

2016-11-30

DS8880 R8.2 & Flash

DACH User Group Meeting

Page 2: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems 2

Enterprise Storage Systems

XIVDS8000

Storwize V5000

Midrange and Entry Storage Systems

Software-Defined Storage: IBM Spectrum

TS7700 Virtual Tape

FlashSystem V9000/A9000

StorwizeV3700

Storwize V7000& Unified

Integrated Solutions and Appliances

Tape and Virtual Tape SystemsStorage Systems

Elastic Storage ServerVersaStack

FlashSystem 900

Control Protect Archive Virtualize Scale Accelerate

Tape Libraries

ProtecTIERDeduplication

TS7700

Enterprise and LTO Tape Drives

IBM PurePower

PureFlex

IDEA

IBM Power Cloud

DeepFlash

IBM Storage Landscape

Page 3: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems 33

2004 2009

POWER5 POWER6

Over 6-9’s availability when DS8000 with Metro Mirror is combined with GDPS/PPRC HyperSwap, or AIX HyperSwap

2010

POWER6+

2006

POWER5+

2012

POWER7

DS8100

DS8300

DS8300

TurboDS8700

2013

POWER7+

2015

POWER8

Replication and Microcode Compatibility

2016

POWER8

DS8800DS8870POWER7

DS8870POWER7+

DS8884DS8886

DS8888

R8.2

DS8888 – 8th generation DS8000 enterprise disk system

Page 4: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems 4

DS8 Advanced F(X)

2 – 3 Times 8870 Perf

19” Rack

2 TB Cache (DRAM)

128 Ports

1536 HDD/SDD’s

IBM is introducing a family of business-critical hybrid data systems that span a wide range of price points. The family is powered by the next generation of IBM's proven DS8000 platform and delivers critical application acceleration, uncompromising availability and industry-leading capabilities.

DS8884 DS8886 DS8888

Fast

Hybrid Flash

€€ starting very low

256 GB Cache (DRAM)

64 ports

1 to 3 frames

768 HDD/SSD + 120 Flash modules

19″ Rack

Faster: 2× Performance

Hybrid Flash

2 TB Cache (DRAM)

128 ports

1 to 5 frames

1536 HDD/SSD’s + 240 Flash modules

19″ Rack

Industry’s Fastest T1 Subsystem

All-flash

2 TB Cache (DRAM)

128 ports

1 or 2 frames

480 Flash modules

19″ Rack

Introducing the DS8880 family of data systems

Page 5: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 55

Announcement date: 20 October 2015

Availability date: 4 December 2015

IBM POWER8 processor technology

Machine type models – 2831 / 2832 / 2833 / 2834

DS8886

Model 981 and Model 98E Expansion Unit

DS8884

Model 980 and Model 98B Expansion Unit

Scalable system memory and scalable processor cores in the controllers

Improved rack power system

New I/O bay interconnect

Improved I/O enclosure bays

Standard industrial rack packaging

Small form factor Hardware Management Console (HMC)

Model conversion from DS8870 Enterprise Class to DS8886 available

Introduces a new advanced function licence packaging

Base functions licence

Copy Services licence

z-synergy licence

DS8880 Family – R8.0

Page 6: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 6

Announcement date: 31 May 2016

Availability date: 10 June 2016

DS8888 (All-flash)

Model 982 and Model 98F Expansion Unit

Three-phase power supplies for DS8886 and DS8888

Small extents

Thin Provisioning for CKD

Easy Tier support for Small extents

Security enhancements

SuperPAV

CSM on HMCs

OpenStack M/N

REST: New APIs

DS Open API: SMI-S 1.6 / SCVMM support

Drive options: 1.8 TB/10K rpm, 6 TB/7200 rpm HDDs, 800 GB Flash cards

R8.2: Announcement date: 2 November / Availability date: 9 December 2016

Hardware: New DS8884/DS8886 submodel options with HPFE Gen-2 and Flash RAID Adapter

Software

DS8880 Family – R8.1

Page 7: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 7

DS8884

• Model 980

• Expansion racks are 98B

• Maximum of 3 racks (base + 2 expansion)

• 19″ 40U rack

• Based on Power 8 S822

• 6-core processors at 3.891 GHz

• Up to 64 host adapter ports

• Up to 256 GB processor memory

• Up to 768 drives

• Up to 4 Flash enclosures

• 2 Flash enclosures in base rack with 2

additional in first expansion rack

• Option for 1 or 2 HMCs installed in base frame

• Single-phase power

• Software function licences can be configured

based on customer usage and not the total

physical capacity of the system

• No upgrade path to DS8886

•DS8886

• Model 981

• Expansion racks are 98E

• Maximum of 5 racks (base + 4 expansion)

• 19″ 46U rack

• 40U with a 6U top hat that is installed as part

of the install when required

• Based on Power 8 S824

• Options for 8- / 16- / 24-core processors at

3.525 or 3.891 GHz

• Up to 128 host adapter ports

• Up to 2 TB processor memory

• Up to 1536 drives

• Up to 8 Flash enclosures

• 4 Flash enclosures in base rack with 4

additional in first expansion rack

• Option for 1 or 2 HMCs installed in base frame

• Single-phase, or three-phase power

DS8884 versus DS8886

Page 8: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 8

IBM Systems 8

19″ rack

40 to 46U

DS8300 DS8700 DS8800 DS8870 DS8880

Disk FC FC SAS SAS SAS

Power Bulk Bulk Bulk DC-UPS DC-UPS

CEC p5/p5+ p6 p6 p7/p7+ p8

IO Bay RIOG PCIe-1 PCIe-1 PCIe-2 PCIe-3

Adapters 4Gb/2Gb 4Gb/2Gb 8Gb/8Gb 16Gb/8Gb 16Gb/8Gb

33″ rack

40U

Rack 33″ 33″ 33″ 33″ 19″

The story of an architecture evolution

Page 9: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 9

DS8884

12 cores per system (6 cores per node)

Up to 256 GB of system memory

Maximum of 64 16Gb FCP/FICON ports

Maximum of 768 HDD/SSD drives

Maximum of 120 Flash Cards

19″, 40U rack

DS8886

Up to 48 cores per system (24 cores per node)

Up to 2 TB of system memory

Maximum of 128 16Gb FCP/FICON ports

Maximum of 1536 HDD/SSD drives

Maximum of 240 Flash Cards

19″, 46U rack

All-Flash DS8888

Up to 96 cores per system (48 cores per node)

Up to 2 TB of system memory

Maximum of 128 16Gb FCP/FICON ports

Maximum of 480 Flash Cards

19″, 40U rack (982)

DS8880 Family – Built with Power 8 Technology

Page 10: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 10

Base Frame Expansion Frame

SSD/DDM Media Enclosure

High-Performance Flash Enclosure

I/O Bay Enclosure

DC-UPS

P8 Servers

SSD/DDM Media Enclosure

High-Performance Flash Enclosure

I/O Bay Enclosure

DC-UPS

1 or 2 HMC

DS8886 Architecture

Page 11: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 11

New Mini HMC allows for 2 HMCs to

be integrated into base Rack.

Keyboard / display slide out

from side of rack

Small HMC allows for 1 or

2 to be installed under

DC-UPS

Configuration Options:

•DS8880 can support one or two HMCs in the base

frame. Second HMC can be concurrently installed

after initial install if desired. No cross coupling of

HMCs allowed in DS8880

HMC and Keyboard/Display

Page 12: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 12

• 3.5″ Nearline – 7200 RPM Native SAS• Extremely high density, direct SAS interface

• 4 TB / 6 TB drives

• 2.5″ Enterprise Class 15K RPM• Drive selection traditionally used for OLTP

• 300 / 600 GB drives

• 2.5″ Enterprise Class 10K RPM• Large capacity, much faster than Nearline

• 600 GB / 1.2 TB / 1.8 TB

• Flash – High-Performance Flash Enclosure• 400 / 800 GB card 1.8″

• SSD – 2.5″ Small Form Factor• Latest generation with higher sequential bandwidth

• 400 / 800 / 1600 GB SSD

Perform

ance

All drives support

encryption at rest

• + R8.2: 400 / 800 / 1600 / 3200 GB card 2.5″ Gen-2

DS8880 Available Drive Technology

Page 13: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems 13

IOPS

Cut IO Wait Time

80%+LatencyUnder

300

Microseconds

No application

or architecture

changes

Benefits &

economics outweigh

disk

Reduce floor space,

power & cooling

Servers, Applications and

Databases are FASTER!

Go FROM5 milliseconds to

under 400

microseconds

HighestReliability levels

Purpose-built,

Enterprise Architecture

Flash enables increased IOPS and CPU savings Flash enables consistently reduced latency

Flash enables environmental efficiencies DS8880 delivers trusted Enterprise Reliability

Why DS8880 with Integrated Flash?

Page 14: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems 14

• 1U drawer … 30 Flash cards (1.8″ form factor)

− developed in synergy with System p, FlashSystem and DS8000 development teams

• Optimised for true flash performance

• Integrated RAID and switch function

− Capabilities that are provided in the Device Adapter (RAID) and Storage Enclosure

(switch) for traditional HDDs and SSDs

• Two large-cache SAS adapters especially designed for Flash

− With 800 GB drives = up to 24 TB raw

− Directly connected to DS8000 internal PCIe fabric

• High-Performance Flash Enclosure is x8 PCIe attached to both POWER8 servers in

the base frame

− New slot positions in I/O bays are used

− DS8870: x4 attachment / + adapter cards to redrive the PCIe signal to the enclosure

• Enterprise class RAS

- High-Availability 2W Cluster

- RAID 5/10 mirrored/protected write cache

• Easy Tier enabled

DS8000 integration of high-performance flash storage: Gen-1

Page 15: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 15

High-Bandwidth, Fault-Tolerant Interconnect

SAN

Persistent memory

Cache memoryN-way

SMP

Persistent memory

Cache memory N-waySMP

RAIDAdapters

RAID

Adapters

Host

AdaptersHost

AdaptersHost

AdaptersHost

AdaptersHost

AdaptersHost

Adapters

Host Host Host

High-Speed PCIe IO Fabric

Intelligent

SAN/Host

Adapters

Enterprise

Controller

Hardware

High-

availability

RAID

adapters

High-Performance Flash Enclosure

– bypassing RAID adapters:

RAID calculation within HPFE. High-speed PCIe adapters for passthrough only/DS8870 only.

Flash Architecture: DS88x0 Internal Topology with HPFE

Page 16: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 16

4-port 16 Gb host adapters

can be installed in Host

Adapter Slots 1, 2, 4 and 5

High-Performance Flash

PCIe direct connect to HPF

enclosures I/O

En

clo

sure

Ho

st A

dap

ter

Slo

t 1

Ho

st A

dap

ter

Slo

t 2

Dev

ice

Ad

apte

r Sl

ot

3

Ho

st A

dap

ter

Slo

t 4

Ho

st A

dap

ter

Slo

t 5

Dev

ice

Ad

apte

r Sl

ot

6

PC

Ie G

en2

HPF Slot 7 PCIe Gen3

PC

Ie G

en2

PC

Ie G

en2

PC

Ie G

en2

PC

Ie G

en2

PC

Ie G

en2

HPF Slot 8PCIe Gen3

Device adapter slots are

used to connect to SSD,

Enterprise and Nearline

drives

Adapter Install Locations

Page 17: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems 17

17

Adjustable top enables rack to stretch from 40U to 46U once rack is in place

• Can be performed by a single SSR – no heavy components

• Top is never removed from the rack

• Extension to the front and rear door to cover

• Can be added as a MES without disruption

Base 40U

rack

Remove bolts to release

top. Extend top up, one

end at a time.

Add side panel/EIA rails and secure

with bolts. Release extension corner

posts and lock down.

Final assembly with

top extended to 46U

Extendable Top Rack (DS8886 and DS8888)

Page 18: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 18

• 19″ 40U Rack

- Max of 2 Rack

• 2 P8 Alpine 4S4U CEC's

• 4x IO Bay Pairs

-2x IO Bay Pair in A Rack

- 2x IO Bay Pair in B Rack

• Max of 128 Ports Host Ports

- 128 ports with 8Gb 4/8-port Host Adapter

- 128 ports with 16Gb 4-port Host Adapter

• Max 0 DA Pairs Supported

• Max of 16 HPFE Drawers/480 flash drives

- 400 GB Flash Drives for 192 TB Raw

- 800 GB Flash Drives for 384 TB Raw

- Supports intermix of 400GB/800GB in system (not in enclosure)

• 2 12U DC-UPS Three Phase per Rack 1 or 2 HMC option

- Single BSM set

- No Single-Phase DC-UPS/Three-Phase DC-UPS intermix

• 1 or 2 HMC option

Max HDD-SDD/Flash/Total

DS8888 (982) Physical Layout, Three-Phase Power

Page 19: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 19

Model Proces-

sors per

CEC

Processor

Cards per

CEC

Available

Threads

System

Memory

NVS Expan-

sion

Frame

Max DA Pairs

/ Max HAs

Max Flash /

Max DDMs+

SSDs

DS8884 Business Class – Single-Phase

980 6-core 1× 6 core 24 64 4 0 2 / 8

(32 ports)

60 / 240

980 6-core 1× 6 core 24 128

256

8

16

0 to 2 4 / 16

(64 ports)

120 / 768

DS8886 Enterprise Class – Single-Phase and Three-Phase

981 8-core 1× 8 core 32 128

256

8

16

0 4 / 16

(64 ports)

120 /

192 1-Ph.

144 3-Ph.

981 16-core 2× 8 core 64 256

512

16

32

0 to 4 8 / 32

(128 ports)

240 / 1536

981 24-core 2×12 core

96 1024

2048

64

64

0 to 4 8 / 32

(128 ports)

240 / 1536

DS8888 Analytics Class – Three-Phase

982 24-core 2×12 core

96 1024 64 0 0 / 16

(64 ports)

240 / 0

982 48-core 4×12 core

192 2048 64 0 to 1 0 / 32

(128 ports)

480 / 0

DS8880 Configuration Summary (R8.0/R8.1)

Page 20: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 20

DS8880 Configuration Summary (R8.2/R8.2.1)Model Proces-

sors per

CEC

Processor

Cards per

CEC

Available

Threads

System

Memory

NVS Expan-

sion

Frame

Max DA Pairs

/ Max HAs

Max Flash

Gen-2 / Max

DDMs+SSDs

DS8884 Business Class – Single-Phase

984 6-core 1× 6 core 24 64 4 0 1 / 8

(32 ports)

48 / 192

984 6-core 1× 6 core 24 128

256

8

16

0 to 2 4 / 16

(64 ports)

96 / 768

DS8886 Enterprise Class – Single-Phase and Three-Phase

985

986

8-core 1× 8 core 32 128

256

8

16

0 4 / 16

(64 ports)

96 /

144 1-Ph.

96 3-Ph.

985

986

16-core 2× 8 core 64 256

512

16

32

0 to 4 8 / 32

(128 ports)

192 /

1536 1-Ph.

1440 3-Ph.

985

986

24-core 2×12 core

96 1024

2048

64

64

0 to 4 8 / 32

(128 ports)

192 /

1536 1-Ph.

1440 3-Ph.

DS8888 Analytics Class – Three-Phase (R8.2.1/Preview)

988 24-core 2×12 core

96 1024 64 0 0 / 16

(64 ports)

192 / 0

988 48-core 4×12 core

192 2048 64 0 to 1 0 / 32

(128 ports)

384 / 0

Page 21: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 21

IBM Systems 21

7a4

7b4

7a3

7b3

7a2

7b2

7a1

7b1

6a4

6b4

11U

6a1

6b1

3a2

3b2

3a4

3b4

3a3

3b3

6a3

6b3

6a2i

6b2

2a1

2b1

3a1

3b1

2a3

2b3

2a4

2b4

2a2

2b2

3U

HMC HMC

3U40

38

36

34

32

30

28

26

24

22

20

18

16

14

12U

10U

8U

6U

4U

2U

DS8884 (984) Physical Layout, Single-Phase Power

Rack Size 19″, 40U

Max number of racks 3

Power8 2S2U CEC 2

IO Bay Pairs 2

• 1 IO Bay Pair in A Rack

• 1 IO Bay Pair in B Rack

Max Ports 64

• 64 ports with 8Gb 4/8 port Host Adapter

• 64 ports with 16Gb 4 port Host Adapter

Max DA Pairs 4

Max DDMs/SSD 768

• Max 32 DDM/SSD Enclosure drawers

Max Flash cards 96

Max HPFE Gen2 2

• 1 HPFE Gen2 in A Rack

• 1 HPFE Gen2 in B Rack

DC-UPS Single

phase per rack

2, 8U

• (3-Phase is not supported)

HMC 1 or 2

HPFE Gen2 1

HPFE Gen2 2

48 / 192 / 240 48 / 240 / 288 0 / 336 / 336 Flash Cards / HDD-SSD / Total

96 / 768 / 864

Page 22: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 22

IBM Systems 22

DS8886 (985) Physical Layout, Single-Phase Power

22U

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

2a1

2b1

0a1

0b1

3a1

3b1

HMCHMC

2U 2U

6a1

6b1

4a1

4b1

7a1

7b1

5a1

5b1

1b1

1a11U

Rack Size 19″, 46U

Max number of

racks

5

Power8 2S2U

CEC

2

IO Bay Pairs 4• 2 IO Bay Pair in A Rack

• 2 IO Bay Pair in B Rack

Max Ports 128• 128 ports with 8Gb 4/8 port Host Adapter

• 128 ports with 16Gb 4 port Host Adapter

Max DA Pairs 8

Max DDMs/SSD 1536• Max 64 DDM/SSD Enclosure drawers

Max Flash cards 192

Max HPFE Gen2 4

• 2 HPFE Gen2 in A Rack

• 2 HPFE Gen2 in B Rack

DC-UPS Single

phase per rack

2, 8U

• No Phase intermix

HMC 1 or 2

96 / 144 / 240 96 / 240 / 336 0 / 432 / 432 0 / 432 / 432 0 / 288 / 288 Flash cards /HDD-SSD / Total

HPFE Gen2 2

HPFE Gen2 1

0a2

0b2

3a2

3b2

1a2

1b2

7a2

7b2

5a2

5b2

2a2

2b2

2a3

2b3

4a2

4b2

6a2

6b2

HPFE Gen2 4

HPFE Gen2 3

6a3

6b3

4a3

4b3

7a3

7b3

5a3

5b3

1a3

1b3

2a4

2b4

0a4

0b4

3b3

3a3

0a3

0b3

6a4

6b4

4a4

4b4

7a4

7b4

5a4

5b4

3b4

3a4

1a4

1b4

192 / 1536 / 1728

Page 23: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 23

IBM Systems 23

DS8886 (986) Physical Layout, Three-Phase Power96 / 96 / 192 96 / 192 / 288 0 / 384 / 384 0 / 384 / 384 0 / 384 / 384 Flash cards / HDD-SSD / Total

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

2U

6a4

6b4

4a4

4b4

7a4

7b4

6a4

6b4

2a3

2b3

0a4

0b4

3a4

3b4

1a4

1b4

2U

6a2

6b2

4a3

4b3

7a3

7b3

6a3

6b3

1a3

1b3

0a3

0b3

2a2

2b2

3a3

3b3

2U

0a2

0b2

3a2

3b2

1a2

1b2

7a2

7b2

6a2

6b2

2a1

2b1

6a1

6b1

4a2

4b2

2U1a1

1b1

4a1

4b1

7a1

7b1

6a1

6b1

0a1

0b1

3a1

3b1

HMC HMCHMC HMC

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 3

HPFE Gen2 4

Rack Size 19″, 46U

Max number of

racks

5

Power8 2S2U

CEC

2

IO Bay Pairs 4• 2 IO Bay Pair in A Rack

• 2 IO Bay Pair in B Rack

Max Ports 128• 128 ports with 8Gb 4/8 port Host Adapter

• 128 ports with 16Gb 4 port Host Adapter

Max DA Pairs 8

Max DDMs/SSD 1440• Max 60 DDM/SSD Enclosure drawers

Max Flash cards 192

Max HPFE Gen2 4

• 2 HPFE Gen2 in A Rack

• 2 HPFE Gen2 in B Rack

DC-UPS Three

Phase per Rack

2, 12U

• No Phase intermix

HMC 1 or 2

192 / 1440 / 1632

Page 24: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems

|

24

24

Preview!

DS8888 (988) Physical Layout, Three-Phase Power (R8.2.1)

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

8U

HMC HMCHMC HMC

192 192 Flash Cards

Total: 384

Rack Size 19″, 46U

Max number of racks 2

Power8 Alpine 4S4U CEC 2

IO Bay Pairs 4 2x IO Bay Pair in A Rack

2x IO Bay Pair in b Rack

Max Ports 128 128 ports with 8Gb 4/8 port Host Adapter

128 ports with 16Gb 4 port Host Adapter

Max Flash cards 384

Max HPFE Gen2 8 4 HPFE Gen2 in A Rack

4 HPFE Gen2 in B Rack

12U DC-UPS Three Phase

per Rack

2

Single-phase is not supported

HMC 1 or 2

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 3

HPFE Gen2 4

HPFE Gen2 5

HPFE Gen2 6

HPFE Gen2 7

HPFE Gen2 8

Page 25: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 25

IBM Systems 25

SSD refers to a flash media based storage device that is accessed and

managed as a logical disk drive, consisting of a standard disk drive

interface (such as SAS or SATA). Their sizes are 1.8 and 2.5 inches

Flash technology can be used in many forms …

IBM Systems Flash Storage Offerings

All-flash array (AFA)

Mixed

(HDD/SSD/CFH)All-Custom Flash

Hardware (CFH)All-SSD

Hybrid-flash array (HFA)

CFH defines an architecture that uses optimised flash modules to provide

better performance and lower latency than SSDs. Examples of CFH are:

• High-Performance Flash Enclosure Gen-2

• FlashSystem MicroLatency Module

• All-flash arrays are storage solutions that only use

flash media (CFH or SSDs) designed to deliver maximum

performance for application and workload where speed is critical.

• Hybrid-flash arrays are storage solutions that

support a mix of HDDs, SSDs and CFH designed to provide a

balance between performance, capacity and cost for a variety of

workloads

The DS8880 Family offers All-flash and Hybrid-flash with CFH,

SSD and HDD configurations designed to satisfy a wide range of

business needs from superior performance to cost efficient

requirementsSource: IDC's Worldwide Flash in the Datacenter Taxonomy, 2016

Page 26: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 26

IBM Systems 26

Flash brings real benefits that justify the investment by far …

Besides the performance benefits, there are additional compelling advantages when

adopting Flash technology

Source: Justifying Investment in All-Flash Arrays. IDC August 2016

1.Meet or exceed the performance

level agreements with far fewer

devices

2.Flash requires lower energy

and less floor space

consumption

3.Fewer servers are required

due to better CPU utilization

4. Fewer servers require

less spending on

software licenses

5. Lower operating and

administrative costs

6. Better reliability since flash is

based on electronic rather

than mechanical media

Page 27: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 27

IBM Systems 27

Source: Worldwide External Enterprise Storage Systems Forecast, 2016–2020, Publication Date: IDC July 2016

Future view of the All-flash and Hybrid-flash market …

74.5% of the business revenue will be flash-based (AFA and HFA) by 2020

All Hard Disk Drive

Hybrid Flash

All Flash5.64% 11.20% 16.28% 20.38% 24.05% 27.38% 29.28%

42.11% 41.70% 42.64% 43.85% 44.66% 45.63% 45.25%

Page 28: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 28

28

Introducing the new DS8880 ALL-flash family

DS8884 DS8886 DS8888

1Q2017

All-flash storage solutions for every business need

Affordable business-class storage

solution with All-Flash performance

packaged in a single rack

Enterprise-class storage designed to

support a wide variety of mission-critical

workloads and applications

Analytic-class storage with superior performance

and capacity able to address the most demanding

business workload requirements

• Lowest entry cost for midrange enterprises

• 256 GB Cache (DRAM)

• 64 Fibre Channel/FICON ports

• 6.4 TB to 154 TB of Flash Capacity

• Higher performance for large enterprises

• 2 TB Cache (DRAM)

• 128 Fibre Channel/FICON ports

• 6.4 TB to 614.4 TB of Flash Capacity

• Industry’s fastest T1 Subsystem

• 2 TB Cache (DRAM)

• 128 Fibre Channel/FICON ports

• 6.4 TB to 1.22 PB of Flash Capacity

Business

Class Analytics

Class

During the first quarter of 2017, IBM plans to enrich the D8880 portfolio with new all-flash versions of DS8884, DS8886 and DS8888

Preview! Preview! Preview!

Enterprise

Class

Page 29: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 29

29

DS8884AF Physical layout for R8.2.1

Rack Size 19″, 40U

Max number of racks 1

Power8 2S2U CEC 2

IO Bay Pairs 1

Max Ports 32

• 32 ports with 8Gb 4/8 port Host Adapter

• 32 ports with 16Gb 4 port Host Adapter

Max Flash cards 48

Max HPFE Gen2 1

8U DC-UPS Single

phase per rack

2

• 3-Phase is not supported

HMC 1 or 2

48 Flash Cards

Total: 48

HMC HMC

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12U

10U

8U

6U

4U

2U

18U

HPFE Gen2 1

Preview!

Page 30: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 30

30

Rack Size 19″, 40U

Max number of racks 1

Power8 2S2U CEC 2

IO Bay Pairs 1

Max Ports 32

• 32 ports with 8Gb 4/8 port Host Adapter

• 32 ports with 16Gb 4 port Host Adapter

Max Flash cards 192

Max HPFE Gen2 4

8U DC-UPS Single

phase per rack

2

• 3-Phase is not supported

HMC 1 or 2

DS8884AF Physical layout for R8.3

HMC HMC

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12U

10U

8U

6U

4U

2U

6U

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 3

HPFE Gen2 4

192 Flash Cards

Total: 192

Preview!

Page 31: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 31

31

DS8886AF Physical layout for R8.2.1

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2HMCHMC

12U

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2HMC HMCHMC HMC

TH 7

TH 7

TH 8

TH 8

20U

16U

TH 3

TH 4

TH 4

8U

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 3

HPFE Gen2 4

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 3

HPFE Gen2 4

Single-Phase DC-UPS only Three-Phase DC-UPS only

Rack Size 19″, 46U

Max number of

racks

2

Power8 2S4U CEC 2

IO Bay Pairs 4 2x IO Bay Pair in A Rack

2x IO Bay Pair in b Rack

Max Ports 128 128 ports with 8Gb 4/8 port Host Adapter

128 ports with 16Gb 4 port Host Adapter

Max Flash cards 192

Max HPFE Gen2 4 2 HPFE Gen2 in A Rack

2 HPFE Gen2 in B Rack

HMC 1 or 2

96 96 Flash Cards 96 96

Total: 192

Preview!

Page 32: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 32

32

DS8886AF Physical layout for R8.3

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2HMCHMC

4U

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2HMC HMCHMC HMC

12U

8U

TH 3

TH 4

TH 4

8U

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 5

HPFE Gen2 6

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 5

HPFE Gen2 6

Single-Phase DC-UPS only Three-Phase DC-UPS only

Rack Size 19″, 46U

Max number of

racks

2

Power8 2S4U CEC 2

IO Bay Pairs 4 2x IO Bay Pair in A Rack

2x IO Bay Pair in b Rack

Max Ports 128 128 ports with 8Gb 4/8 port Host Adapter

128 ports with 16Gb 4 port Host Adapter

Max Flash cards 384

Max HPFE Gen2 8 4 HPFE Gen2 in A Rack

4 HPFE Gen2 in B Rack

HMC 1 or 2

192 192 Flash Cards 192 192

Total: 384

HPFE Gen2 3

HPFE Gen2 4

HPFE Gen2 7

HPFE Gen2 8

HPFE Gen2 3

HPFE Gen2 4

HPFE Gen2 7

HPFE Gen2 8

Preview!

Page 33: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 33

33

All-flash DS8888 Physical layout for R8.2.1

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

8U

HMC HMCHMC HMC

192 192 Flash Cards

Total: 384

Rack Size 19″, 46U

Max number of racks 2

Power8 Alpine 4S4U CEC 2

IO Bay Pairs 4 2x IO Bay Pair in A Rack

2x IO Bay Pair in b Rack

Max Ports 128 128 ports with 8Gb 4/8 port Host Adapter

128 ports with 16Gb 4 port Host Adapter

Max Flash cards 384

Max HPFE Gen2 8 4 HPFE Gen2 in A Rack

4 HPFE Gen2 in B Rack

12U DC-UPS Three Phase

per Rack

2

Single phase is not supported

HMC 1 or 2

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 3

HPFE Gen2 4

HPFE Gen2 5

HPFE Gen2 6

HPFE Gen2 7

HPFE Gen2 8

Preview!

Page 34: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 34

34

All-flash DS8888 Physical layout for R8.3

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

8U

HMC HMCHMC HMC

192 288 Flash Cards

Total: 480

Rack Size 19″, 46U

Max number of racks 2

Power8 Alpine 4S4U CEC 2

IO Bay Pairs 4 2x IO Bay Pair in A Rack

2x IO Bay Pair in b Rack

Max Ports 128 128 ports with 8Gb 4/8 port Host Adapter

128 ports with 16Gb 4 port Host Adapter

Max Flash cards 480

Max HPFE Gen2 10 4 HPFE Gen2 in A Rack

6 HPFE Gen2 in B Rack

12U DC-UPS Three Phase

per Rack

2

Single-phase is not supported

HMC 1 or 2

HPFE Gen2 1

HPFE Gen2 2

HPFE Gen2 3

HPFE Gen2 4

HPFE Gen2 5

HPFE Gen2 6

HPFE Gen2 7

HPFE Gen2 8

HPFE Gen2 9

HPFE Gen2 10

Preview!

Page 35: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 35

IBM Systems 35

High-Performance Flash Enclosure Gen-2 is a breakthrough in technology

1 to 1

High-Performance Flash Enclosure High-Performance Flash Enclosure Gen-2

Size 1U 4U

Flash card options 400 / 800 GB 400 / 800 / 1600 / 3200 GB

Number of supported flash

cards

16 or 30 (1.8″) 16, 32 or 48 (2.5″)

Max raw capacity 24 TB1 153.6 TB2 Over 6x

RAID protection 5 / 10 6 / 10 / 5

Attachment Two PCIe Gen-2 • Two PCIe Gen-3 for attachment to the IO / Microbay

• Eight SAS for attachment to the Gen-2 enclosure

Install groups 2 install groups of 16 Flash cards and 14 Flash cards

(4 array sites)

3 install groups of 16 Flash cards each

(6 array sites)

Increments Populate in increments of a single

High-Performance Flash Enclosure

Populate in increments of a single storage group consisting of:

One High-Performance Flash Enclosure Gen-2 pair + Two IO / Microbays

Performance IOPS Throughput IOPS Throughput

Read 340,000 3.8 GB/s Read 650,000 +90% 12 GB/s +216%

Write 200,000 2.7 GB/s Write 300,000 +50% 5 GB/s +85%

1 30 flash cards x 800 GB2 48 flash cards x 3.2 TB

Page 36: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 36

IBM Systems 36

Flash RAID AdapterPCIe Switch Card

Fan Assembly

Enclosure Front View

Enclosure Rear View

Terapack

12Gb SAS Expander

12Gb SAS Expander

24 FlashCards

Terapack

12Gb SAS Expander

12Gb SAS Expander

24 Flash Cards

Microbay

Flash RAID Ad.

x4 SAS

x4 SAS

x4 SAS

x4 SAS

Switch Card

PLX

Switch

PP

C–P

PC

Microbay

Flash RAID Ad.

x4 SAS

x4 SAS

x4 SAS

x4 SAS

Switch Card

PLX

Switch

PP

C–P

PC

Microbay

Terapacks

New Flash Hardware

Page 37: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 37

IBM Systems 37

RAID-6 for mission-critical protection

Drive media is rapidly increasing in capacity to 10 TB and more. The greater density provides real

cost advantages but requires changes in the types of RAID protection used.

In order to improve data availability, IBM moves protection to the next level by enabling RAID-6

as default in the GUI for all drive types.

1 2 3 4 5 6 P

S

RAID-5

1 2 3 4 5 Q P

S

RAID-6

RAID-5 uses one parity drive whereas RAID-6 uses two

RAID-6 ensures business continuity for mission-critical applications because: Data is still protected event if a second drive fails while the first failed drive is being rebuilt

Information placed in unreadable regions in a specific drive can be detected, isolated and recovered

from the remaining drives

RAID-6 provides a 1000x improvement over RAID-5 for impact risk

The use of RAID-6 rather than RAID-5 can dramatically reduce the probability of drive failures

providing increased protection for workloads where data integrity is critical

The DS8880 family takes the increased risks posed by high-capacity drives very seriously

Page 38: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems 38

GUI: Performance views

Page 39: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 39

IBM Systems 39

GUI improvements: Host creation, managing clustered hosts,embedded CLI

Automatic creation

based on unassigned

host ports

Page 40: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 40

IBM Systems 40

Syslog servers / Customer certificates for encryption / setfirewall

Page 41: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 41

IBM Systems 41

IBM DS8880 Family: All-flash and Hybrid-flash Made for Business-Critical Workloads

DS8884 DS8886 DS8888

Affordable hybrid-flash block storage

solution for midrange enterprises

Faster hybrid-flash block storage for large

enterprises designed to support a wide variety of

application workloads

Fastest all-flash block storage with superior

performance designed to address the most

demanding business workloads

Model984

985 (Single-Phase)

986 (Three-Phase)982 / 988

Cache 256 GB 2 TB 2 TB

FC/FICON ports 64 128 128

Media768 HDD/SSD

96 Flash cards

1536 HDD/SSD

192 Flash cards480 / 384 Flash cards

Max raw capacity 2.6 PB 5.2 PB 384 TB / 1.2 PB

Business

Class

Enterprise

Class

Analytics

Class

IBM DS8880 is the business-critical storage family designed to offer a wide range of price points. This enterprise storage data

systems are powered by the next generation of IBM’s proven DS8000 platform and deliver critical application acceleration,

uncompromising availability and industry-leading capabilities.

Page 42: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems 42

Questions???

Thank You!!!

Page 43: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

Backup Slides

Page 44: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 44

IBM Systems 44

7a4

7b4

7a3

7b3

7a2

7b2

7a1

7b1

6a4

6b4

11U

240/60/300 288/60/248 240/0/240

6a1

6b1

3a2

3b2

3a4

3b4

3a3

3b3

HPFE

HPFE

6a3

6b3

6a2i

6b2

2a1

2b1

3a1

3b1

2a3

2b3

2a4

2b4

2a2

2b2

1UHPFE

HPFE

1U

HMC HMC

1U40

38

36

34

32

30

28

26

24

22

20

18

16

14

12U

10U

8U

6U

4U

2U

19″ 40U Rack

Max of 3 Racks

2x P8 2S2U CEC's

2x IO Bay Pairs

1 IO Bay Pair in A Rack

1 IO Bay Pair in B Rack

Max of 64 Ports

64 ports with 8Gb 4/8 port Host Adapter

64 ports with 16Gb 4 port Host Adapter

Max 4 DA Pairs

Max of 768 DDMs/SSD’s

Max 32 DDM/SSD Enclosure drawers

Max of 4 HPFE Drawers/120 flash drives

2 HPFE Drawers A Rack

2 HPFE Drawers B Rack

2 8U DC-UPS Single Phase per Rack

(3 Phase is not supported)

1 or 2 HMC option

DS8884 (980) Rack Configuration – R8.0–R8.1

HDD-SSD/Flash/Total

Page 45: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 45

IBM Systems 45

DS8886 (981) Rack Configuration – Single-Phase power R8.0–R8.1

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

19″ 46U Rack

Max of 5 Racks

2x P8 2S4U CEC's

4x IO Bay Pairs

2x IO Bay Pair in A Rack

2x IO Bay Pair in B Rack

Max of 128 Ports

128 ports with 8Gb 4/8 port Host Adapter

128 ports with 16Gb 4 port Host Adapter

Max 8 DA Pairs

Max of 1536 DDMs/SSD’s

Max 64 DDM/SSD Enclosure drawers

Max of 8 HPFE/240 flash drives

4 HPFE Drawers A Rack

4 HPFE Drawers B Rack

2 8U DC-UPS Single Phase per Rack

No Phase intermix

1 or 2 HMC option

HDD-SSD/Flash/Total192/120/312 288/120/408 432/0/432 432/0/432 192/0/192

2a1

2b1

0a1

0b1

3a1

3b1

1a1

1b1

HPFE

HPFE

HPFE

HPFE

HMCHMC

6a1

6b1

4a1

4b1

7a1

7b1

5a1

5b1

6a2

6b2

4a2

4b2

HPFE

HPFE

HPFE

HPFE

0a2

0b2

3a2

3b2

1a2

1b2

7a2

7b2

5a2

5b2

0a3

0b3

2a3

2b3

2U

2a2

2b2

3a3

3b3

6a3

6b3

4a3

4b3

7a3

7b3

5a3

5b3

1a3

1b3

2a4

2b4

0a4

0b4

3a4

3b4

1a4

1b4

2U

6a4

6b4

4a4

4b4

7a4

7b4

5a4

5b4

22U

Page 46: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems | 46

IBM Systems 46

DS8886 (981) Rack Configuration – Three-Phase power R8.0–R8.1

46

44

42

40

38

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

6

4

2

19″ 46U Rack

Max of 5 Racks

2x P8 2S4U CEC's

4x IO Bay Pairs

2x IO Bay Pair in A Rack

2x IO Bay Pair in B Rack

Max of 128 Ports

128 ports with 8Gb 4/8 port Host Adapter

128 ports with 16Gb 4 port Host Adapter

Max 8 DA Pairs

Max of 1536 DDMs/SSD’s

Max 64 DDM/SSD Enclosure drawers

Max of 8 HPFE/240 flash drives

4 HPFE Drawers A Rack

4 HPFE Drawers B Rack

2 12U DC-UPS Three Phase per Rack

No Phase intermix

1 or 2 HMC option

HDD-SSD/Flash/Total192/120/312 288/120/408 432/0/432 432/0/432 192/0/192

2U

6a4

6b4

4a4

4b4

7a4

7b4

5a4

5b4

2a4

2b4

0a4

0b4

3a4

3b4

1a4

1b4

2U

6a3

6b3

4a3

4b3

7a3

7b3

5a3

5b3

1a3

1b3

0a3

0b3

2a3

2b3

3a3

3b3

2U

0a2

0b2

3a2

3b2

1a2

1b2

7a2

7b2

5a2

5b2

2a2

2b2

6a2

6b2

4a2

4b2

2U

HPFE

HPFE

HPFE

HPFE

1a1

1b1

6a1

6b1

4a1

4b1

7a1

7b1

5a1

5b1

HPFE

HPFE

HPFE

HPFE

2a1

2b1

0a1

0b1

3a1

3b1

HMC HMCHMC HMC

Page 47: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM SystemsIBM Systems 47

47

DeepFlash

150

DS8888

Big Data

•High capacity

•High density

• Extreme performance

• Targeting database

acceleration &

Spectrum Storage

booster

FlashSystem 900 Application acceleration

IBM FlashCore™ Technology Optimised

FlashSystem

A9000

FlashSystem

A9000R

•Full-time data

reduction

•Workloads:

Cloud, VDI,

VMware

Large

deployments

FlashSystem

V9000

Virtualising

the DCCloud service

providers

•Full-time data

reduction

•Workloads: Mixed

and cloud

Storwize

V7000F

Mid-Range

Storwize

V5030F

Entry /

Mid-Range

Enhanced data storage functions, economics and flexibility with sophisticated virtualisation

SVC

IBM Systems Flash Storage Offerings Portfolio

Simplified management

Flexible consumption model

Virtualised, enterprise-class, flash-optimised, modular storage

Enterprise class heterogeneous data services and selectable

data reduction

DS8884

Business

class

DS8886

Enterprise

class

Analytics class

with superior

performance

Business critical, deepest integration with

z Systems, superior performance, highest

availability, Three-site/Four-site replication and

industry-leading reliability

Preview!

High availability with IBM PowerHA

z/OS DFSMS

Page 48: DS8880 R8.2 & Flash - IBM...IBM Systems 11 New Mini HMC allows for 2 HMCs to be integrated into base Rack. Keyboard / display slide out from side of rack Small HMC allows for 1 or

IBM Systems

IBM Confidential

Trademarks and Disclaimers

© IBM Corporation 2016. All rights reserved.

References in this document to IBM products or services do not imply that IBM intends to make them available in every country.

AIX, DB2, DS8000, Easy Tier, FICON, FlashCopy, GDPS, HyperSwap, IBM, Power, Power Systems, POWER6, POWER6+, POWER7, POWER7+, POWER8, PowerHA,

Real-time Compression, Redbooks, Redpaper, System i, System p, System z, System Storage, SystemMirror, Tivoli, XIV, z Systems, z13, zHyperWrite, z/OS, FlashSystem, Storwize, ProtecTIER, PureFlex, PurePower System,

Resource Measurement Facility, RMF, IBM Elastic Storage and IBM Spectrum are trademarks or registered trademarks of International Business Machines Corporation.

InfiniBand is a trademark and/or service mark of the InfiniBand Trade Association.

Linear Tape-Open, LTO, and the LTO Logo are trademarks of HPE, IBM Corp. and Quantum in the United States and other countries.Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.Microsoft, and Windows are trademarks of Microsoft Corporation in the United States, other countries, or both.Other company, product, and service names may be trademarks or registered trademarks of their respective companies.

Trademarks of International Business Machines Corporation in the United States, other countries, or both can be found on the World Wide Web at http://www.ibm.com/legal/copytrade.shtml.

Product data has been reviewed for accuracy as of the date of initial publication. Product data is subject to change without notice. This information could include technical inaccuracies or typographical

errors. IBM may make improvements and/or changes in the product(s) and/or program(s) at any time without notice. THE INFORMATION PROVIDED IN THIS DOCUMENT IS DISTRIBUTED

“AS IS” WITHOUT ANY WARRANTY, EITHER EXPRESS OR IMPLIED. IBM EXPRESSLY DISCLAIMS ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE

OR NON-INFRINGEMENT. IBM shall have no responsibility to update this information. IBM products are warranted according to the terms and conditions of the agreements (e.g., IBM Customer

Agreement, Statement of Limited Warranty, International Program License Agreement, etc.) under which they are provided.

The customer examples described are presented as illustrations of how those customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics may vary by customer.

Information concerning non-IBM products was obtained from a supplier of these products, published announcement material, or other publicly available sources and does not constitute an endorsement of such products by IBM. Sources for non-IBM list prices and performance numbers are taken from publicly available information, including vendor announcements and vendor worldwide homepages. IBM has not tested these products and cannot confirm the accuracy of performance, capability, or any other claims related to non-IBM products. Questions on the capability of non-IBM products should be addressed to the supplier of those products.

All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.

Some information addresses anticipated future capabilities. Such information is not intended as a definitive statement of a commitment to specific levels of performance, function or delivery schedules with respect to any future products. Such commitments are only made in IBM product announcements. The information is presented here to communicate IBM's current investment and development activities as a good faith effort to help with our customers’ future planning.

Performance is based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput or performance that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user’s job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput or performance improvements equivalent to the ratios stated here.

48