_____________________ _____________________Folke Mattsson Seppo RaeACS850 Product Manager Senior Test EngineerABB Oy, Drives ABB Oy, Drives
Drive: ACS880-01-169A-3Motor: M3BL 200MLC, 3GBL202002-ASB, Pn 72 kW, 3000 rpm
Speed Speed rpm P/Pn Package efficiency50 %** 1500 13 %** 87.2 %
63 % 1890 25 % 90.1 %75 % 2250 42 % 91.5 %80 % 2400 51 % 92.0 %91 % 2730 75 % 92.7 %
100 %** 3000 100 %** 93.2 %**Estimated tolerance according to IEC 60034-1:
≤150kW: 0.15 x (100 - package efficiency (%)) at the nominal point>150kW: 0.10 x (100 - package efficiency (%)) at the nominal point
**Measurement points according to EN 50598-2 (will be published 2014)
84%
85%
86%
87%
88%
89%
90%
91%
92%
93%
94%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
1000 1500 2000 2500 3000
hP/Pn
rpm
72 kW, 3000 rpm drive systemin pump/fan duty
Pump/Fan power curve SynRM package efficiency
Document no: SEVEN201401200102
Manufacturer’s statementACS880-01 and High output SynRM motor package efficiency
Document no:SEVEN201401200102
Package efficiency [%] for applications with other load characteristics:
Points of measurement
Efficiency η = P2/P1
Efficiency measurements were made at:
ABB verification laboratory, Vaasa X ABB verification laboratory, Västerås
ABB verification laboratory, Helsinki
Mechanical Power P2
Motor Speed
Load
Torq
ue
Electrical Power P1