Upload
nguyenquynh
View
215
Download
0
Embed Size (px)
Citation preview
2 VP-210-1
The Extended Capacity Range
Rango Ampliado de
Capacidad
Displacement (3500 RPM)
Desplazamiento (3500 RPM)
CFH
ACP 95 Series
Nominal Horsepower 400-1000HP
Contents Page
The Special Highlights 2
The Decisive Technical Features 4
Model Number Nomenclature
Performance data
8
9
Technical Data 13
Dimensional Drawings 14
The Next Generation of Screw Compressor Packages
The world’s leading compressor and pressure vessel manufacturer has expanded to meet the demands of the industrial and commercial market with a series of screw compressor packages designed specifically for ammonia. Available with a wide variety of options and accessories, The BITZER Ammonia Compressor Package (ACP) is designed to meet the growing demand for high efficient, natural refrigerant solutions. For over 40 years, BITZER has delivered compressors for the ammonia refrigeration market. These packages now make applying these reliable and efficient compressors easy for any system.
Special Highlights
Heavy duty industrial construction Wide variety of option and accessories Compact design Easy access and easy to service Same designs among different size compressors High efficiency, especially in part load Redundant in compressors, filters and sensors
Serie ACP 95
Potencia Nominal 400-1000 HP
Contenido Página
Lo Más Destacado 2
Características Técnicas Decisivas 4
Nomenclatura
Datos de Desempeño
8
9
Datos Técnicos 13
Dibujos Dimensionales 14
La Siguiente Generación en Paquetes de Compresores
El fabricante de compresores y recipientes líder en el mundo se ha expandido para satisfacer las demandas del mercado industrial con una serie de paquetes de compresores diseñada específicamente para amoniaco.
Disponible con una amplia variedad de opciones y accesorios, los Paquetes BITZER de Compresores de Amoniaco (ACP) están diseñados para satisfacer la creciente demanda de sistemas con refrigerantes naturales de alta eficiencia Por más de 40 años, BITZER ha suministrado compresores para el mercado de refrigeración con amoniaco. Pero ahora, los paquetes hacen más sencillo aplicar estos compresores confiables y eficientes en cualquier sistema.
Lo Más Destacado
Construcción robusta Amplia variedad de opciones y accesorios Diseño compacto Serviceabildad Mismos diseños entre diferentes tamaños de compresores Alta Eficiencia, especialmente en cargas parciales Redundancia en compresores, filtros y sensores
3 VP-210-1
Energy Efficiency
No Suction Check valve
BITZER ACP packages utilize internal check valves
on the compressors to prevent the rotors from
spinning backwards when the compressor is off. This
feature is complemented by an oil solenoid/stop valve
to ensure that oil does not flow while the compressor
is not running. These features eliminate the need for a
suction check valve which would create unnecessary
pressure drop and wasteful system inefficiency!
Automatic Volumetric Index (Vi)
With larger compressors (over 150 tons), it can be
beneficial to have variable Vi control that adjusts the
internal volumes to match the pressure ratio of the
system. A better matched Vi is able to increase the
isentropic efficiency of the compressor process and
reduce power consumption. BITZER accomplishes
this on the 95 Series compressors through a Vi slider
and the new IQ - CM Technology. The IQ module
monitors the pressures of the compressor and
automatically adjusts the Vi valve to the optimum
position to maintain the highest efficiency.
Part Load Efficiency
All of BITZER’s ACP packages can come equipped
with a variable frequency drive. A VFD ensures
system stability and a more efficient part load
performance than other unloading methods. Years of
experience has proven that compressors operate at
part load (75% or below) for the vast majority of time.
A VFD capitalizes on this to increase system
efficiency.
Furthermore, multiple compressors greatly increases
part load efficiency by keeping running compressors
closer to full load, where the efficiency is highest.
Eficiencia Energética
No existe Válvula Check en la Succión
Los paquetes BITZER ACP utilizan válvulas check
internas en los compresores para prevenir que los
rotores giren continuamente en sentido contrario
mientras el compresor esté apagado. Esta característica
además está respaldada por una válvula solenoide de
paro de aceite para asegurar que el aceite no pueda
llenar el compresor o la línea de succión mientras el
compresor está detenido.
Estas características evitan la necesidad de una válvula
check en la succión, la cual podría crear una caída de
presión innecesaria y afectar la eficiencia del sistema!
Indicé Volumétrico Fijo (Vi)
Con compresores grandes (mayores a 150 TR), puede
ser un beneficio tener un índice volumétrico variable Vi
que ajusta los volúmenes internos para que coincidan
con la relación de compresión del sistema. Sin embargo,
esta característica mecánica genera pérdidas en el
proceso de compresión que son difíciles de rectificar con
rotores de diámetros menores. Por esta razón, BITZER
fija el Vi para aplicaciones de baja y media temperatura
e incluso logra mejores eficiencias en la mayoría de los
rangos de aplicación en comparación con un compresor
de la competencia de volumen variable Vi.
Variadores de Velocidad
Todos los paquetes BITZER ACP pueden venir
equipados con un variador de velocidad. Dicho variador
asegura la estabilidad del sistema y una operación más
eficiente a cargas parciales. Años de experiencia han
probado que los compresores operan a cargas parciales
(menores del 75%) la mayor parte del tiempo. Un
variador de velocidad permite mejorar la eficiencia en
cargas parciales.
Por otra parte, varios compresores aumentan en gran
medida la eficiencia de carga parcial, manteniendo los
compresores operando cercanas a plena carga, donde la
eficiencia es mayor.
Vi Slider
Pressure Ratio
Isentropic
Efficiency
4 VP-210-1
The Decisive Technical Features
Latest Screw Technology
High-efficiency profile twin screws using advance
geometry and high rigidity
Wide Speed Range (VFD Optional):
o OS’95: 1450-4000 RPM
Automatic start unloading
Slide Valve with infinite capacity control and Vi
control thanks to an optimized slider concept
Automatic Vi adjustment
Economizer operation (Optional)
High quality shaft seal
Internal pressure relief valve
Compressor integrated discharge check valve
High Efficiency Motors
NEMA premium efficiency C-face motors
Inverter rated duty with 70Hz option for zero loss
of torque above 60Hz
Standard: ODP (IP23)
Option: TEFC (IP55)
Quality
Robust, industrial strength frame
C-Face motor and machined steel housing
ensures perfect motor/compressor shaft alignment
Long lasting “Flender” style coupling increases
shaft to motor reliability
Motors include Aegis ring and ground shaft
current protection for VFD operation
Motor heaters available for high humidity
conditions
Características Técnicas Decisivas
La más Nueva Tecnología de Tornillo
Perfil de tornillos de alta eficiencia que utilizan una
geometría avanzada y robusta
Amplio Rango de Velocidad (Variador de
Velocidad Opcional):
o OS’95: 1450-4000 RPM
Arranque descargado automático
Válvula deslizable de control de capacidad infinito:
Ajuste Automático de Vi
Operación con Economizador (Opcional)
Sello de flecha de alta calidad
Válvula de alivio de presión interna
Válvula check en la descarga integrada en el
compresor
Motores de Alta Eficiencia
Motores NEMA brida “C” de eficiencia premium
Adecuado para uso con un Variador de Velocidad
hasta 70 Hz sin pérdida de torque
Estándar: ODP (IP23)
Opcional: TEFC (IP55)
Calidad
Bastidor robusto tipo industrial
El motor brida C y “housing” de acero maquinado
aseguran la perfecta alineación motor/compresor
Cople tipo “Flender” de larga duración incrementa
la confiabilidad flecha-motor
Los motores incluyen anillos Aegis y protección de
corriente con flecha aterrizada para operación con
variadores de velocidad
Calefactores de motor disponibles para
condiciones de alta humedad
5 VP-210-1
The Decisive Technical Features
Oil Separator
BITZER ASME horizontal coalescing oil separator
Multiple coalescer elements designed to match
application
Pressure rating: 300psi (higher available)
4 Stages of separation
99.9% efficient
Oil Management
5 micron primary oil filtration
Easily accessible oil filter
Individual dedicated redundant secondary filter
Discharge pressure regulator to ensure oil
pressure on startup (and in low ambient).
o Booster applications: Regulator is removed
and an oil pump is added to primary oil line
Oil Cooling
Standard: High efficiency plate heat exchanger
can be used with thermosiphon or water/glycol
cooling
Option: Liquid injection available (controlled via
reliable motorized multifunction valve system)
Sensor and Switches
Pressure and temperature sensors:
o Suction Header
o Discharge (between compressor and
separator)
o Coalescing oil separator basin
o Oil line (pre and post oil filter pressure
sensors)
Las características técnicas decisivas
Separador de Aceite
Separador de aceite horizontal BITZER certificado
ASME
Elementos coalescentes múltiples diseñados para
cada aplicación
Rango de presión: 300 psi (mayores disponibles)
4 Etapas de separación
Eficiencia de separación de 99.9%
Manejo de Aceite
Filtración primaria de aceite a 5 micrones
Filtro de aceite de fácil accesibilidad
Filtro secundario individual y redundante
Regulador de presión de descarga para asegurar
presión de aceite durante el arranque (y en
ambientes de baja temperatura).
o Aplicaciones Booster: El regulador se elimina
y se incluye una bomba de aceite en la linea
principal de aceite
Enfriamiento de Aceite
Estándar: Uso de intercambiador de calor de
placas de alta eficiencia en sistemas termosifón o
en sistemas de enfriamiento por agua o glicol
Alternativa: Inyección de líquido controlado via
válvula motorizada multifuncional (LIOC)
Sensores e Interruptores
Sensores de presión y temperatura:
o Cabezal de Succión
o Línea de descarga (antes de separador)
o Separador de aceite
o Línea de aceite (sensores de presión antes y
después de los filtros de aceite)
6 VP-210-1
The Controller
Controller Functions (Standard)
Compressor capacity control
o Standard: Variable frequency drive
o Option: Mechanical Unloading
Compressor / motor protection:
o Application limit monitoring
- Complete compressor application limits
- Pre-alarm warning
o Low Suction pressure
o Oil temp and pressure monitoring
o Primary and secondary oil filter, oil flow
switch and oil solenoid valve monitoring
o Short cycle protection
o Rotation direction protection
Motor Protection
o High motor amps
o High motor temperature via embedded
thermistors
Economizer control
VFD control and communication via Modbus
Digital Input and Output available for system
Communication
Highly serviceable input and output menu and
panel layout
El Controlador
Funciones del Controlador
Control de capacidad del compresor
o Estándar: Variador de Velocidad
o Opcional: Descarga mecánica
Protección compresor / motor:
o Monitoreo de límites de aplicación
- Límites Monitoreo completo de límites
de aplicación
- Aviso previo de alarmas
o Baja presión de succión
o Monitoreo de temperatura y presión de aceite
o Monitoreo del filtro de aceite primario y
secundario, interruptor de flujo de aceite y
válvula de paro de aceite
o Protección contra arranques consecutivos
(Short cycle)
o Protección de dirección de rotación
Protección de Motor
o Alto amperaje de motor
o Alta temperatura de motor a través de
termistores internos
Control del economizador
Variador de velocidad y comunicación vía
Modbus
Entradas y salidas digitales disponibles para
comunicación con el sistema
Menú de entradas y salidas sencillo y lay out de
panel de fácil servicio
7 VP-210-1
The Controller
Technical Details
UL rated painted enclosure
12” Color Touch Screen
Graphical User Friendly Operator Interface
Replicate display with web browser or smartphone
App
TCP/IP Modbus external communication
Additional Features
Easy and simple menu navigation
Remote PC monitoring
Security / User log-in access levels
Highly serviceable input and output menu and
panel layout
Alarm history and data logging
Historical and live real time data graphing
BITZER IQ: CM Technology
Features
Utilizing the CM-SW Module
Compressor / Oil Separator Mounted
Modbus external communication
Elimination of sensor wiring to controller
(Only power, Modbus, and fault circuit wiring required)
LED lights indicate module status
Easy commissioning and troubleshooting through
BEST Software
Automatic Monitoring and Control
Capacity control (Based on system controller)
Ensures unloaded starting
Automatic internal volume ratio control (Vi)
Alarm history and data logging
Application limit monitoring of suction/discharge
pressure with warning, alarm and shutoff levels
Oil supply and discharge gas temperature
El Controlador
Detalles Técnicos
Gabinete pintado conforme UL
Pantalla en color LCD de 12" Touch Screen
El interface de operación gráfica lo hace amigable
con el usuario
Replicar la pantalla con un navegador web o un
App para el teléfono
Comunicación externa tipo TCP/IP Modbus
Características Adicionales
Menú de navegación simple y sencillo
Monitoreo remoto en PC
Diferentes niveles de acceso: seguridad / usuario
Menú de entradas y salidas amigable
Historial de alarmas y adquisición de datos
Datos en tiempo real
IQ BITZER: Tecnología CM
Características
Uso del modulo CM-SW
Montaje Compresor / Separador de Aceite
Comunicación externa vía Modbus
Eliminación de cableado de sensores hacia el
controlador (Sólo fuerza, Modbus, y cableado de
circuito de falla)
Luces LED indicando el estatus del módulo
Fácil puesta en marca y solución de problemas al
usar software BEST
Monitoreo y Control Automático
Control de Capacidad
Arranque descargado
Relación de volúmen interno automática (Vi)
Histórico de alarmas y adquisición de datos
Monitoreo de presiones de succión y descarga
dentro de los límites de aplicación, con avisos,
alarmas y paro.
Temperatura de suministro de aceite y
temperatura de descarga
8 VP-210-1
Model Number Nomenclature
A C P 9 5 9 3 K -
2K
2 V - H B E P
Series
A C P 9 5 9 3 K -
2K
2 V - H B E P
Compressor Model Frame Size / Displacement
A C P 9 5 9 3 K -
2K
2 V - H B E P
Application Range K = Medium / High Temperature Range N = Low Temperature Application B = Booster Application
A C P 9 5 9 3 K -
2K
2 V - H B E P
Number of Compressors
A C P 9 5 9 3 K -
2K
2 V - H B E P
Capacity Control Method V = Variable frequency drive C = Capacity control (w/o VFD)
A C P 9 5 9 3 K -
2K
2 V - H B E P
Oil Cooling Method
A
H
=
T
h
er
m
os
ip
h
o
n
or
w
at
er
/b
ri
n
e
vi
a
a
H
X
A
C P 9 5 9 3 K -
2K
2 V - H B E P
Controller B = w/Controller
A C P 9 5 9 3 K -
2K
2 V - H B E P
Economizer E = Economizer heat exchanger included
A C P 9 5 9 3 K -
2K
2 V - H B E P
Starter Panel P = Soft-Starter or VFD panel included
Note: Model number does not fully define complete extent of delivery.
Application Limits
Nomenclatura
A C P 9 5 9 3 K -
2K
2 V - H B E P
Serie
A C P 9 5 9 3 K -
2K
2 V - H B E P
Modelo de Compresor Tamaño / Desplazamiento
A C P 9 5 9 3 K -
2K
2 V - H B E P
Rango de Aplicación K = Media / Alta Temperatura N = Baja Temperatura B = Booster
A C P 9 5 9 3 K -
2K
2 V - H B E P
Número de Compresores
A C P 9 5 9 3 K -
2K
2 V - H B E P
Método de Control de Capacidad V = Variador de Velocidad C = Control de Capacidad Mecánico (sin VFD)
A C P 9 5 9 3 K -
2K
2 V - H B E P
Método de Enfriamiento de Aceite
A
In
te
rc
a
m
bi
a
d
or
d
e
ca
lo
r
co
n
ag
u
a
o
te
r
m
os
if
ó
n
A
C P 9 5 9 3 K -
2K
2 V - H B E P
Controlador B = con controlador
A C P 9 5 9 3 K -
2K
2 V - H B E P
Economizador E = Intercambiador de Calor de Economizador incluido
A C P 9 5 9 3 K -
2K
2 V - H B E P
Panel Arrancador P = Panel de Arrancador o Variador Incluido
Nota: El modelo no define totalmente los accesorios incluidos.
Límites de Aplicación
9 VP-210-1
Performance Data (Medium Temp / 60Hz) Datos de Desempeño (Temperatura Media / 60Hz)
Based on 2°F Suction gas superheat, 5°Subcooling Basado en 2°F Sobrecalentamiento, 5°F Subenfriamiento
Package Model*
Cond
. T
em
p Cooling Capacity [TR] Power [kW]
Potencia frigorífica [Toneladas] Potencia [kW]
Modelo* Evaporation Temp °F Temperatura de evaporación °F
°F 45 40 35 25 20 15 10 5 0
ACP9593K-2C
85 TR 835.6 756.4 682.9 552.4 494.7 441.8 393.4 349.3 309.1 kW 336.2 341.1 343.8 343.1 340.1 335.6 329.9 323.0 315.3
95 TR 811.2 733.7 661.9 534.5 478.2 426.7 379.5 336.5 297.4 kW 399.6 401.4 401.2 395.0 389.5 382.7 374.7 365.8 356.1
105 TR 786.6 710.9 640.8 516.4 461.6 411.4 365.4 323.6 285.5 kW 465.4 464.2 461.0 449.5 441.5 432.3 422.1 411.0 399.4
ACP95103K-2C
85 TR 932.2 844.1 762.4 617.2 553.0 494.2 440.3 391.2 346.4 kW 371.9 377.0 379.5 377.9 374.3 369.0 362.3 354.4 345.6
95 TR 905.6 819.5 739.6 597.8 535.2 477.9 425.4 377.5 333.9 kW 441.4 443.0 442.3 434.6 428.1 420.2 411.1 400.9 389.9
105 TR 905.6 819.5 739.6 597.8 535.2 477.9 425.4 377.5 333.9 kW 513.5 511.7 507.7 494.0 484.7 474.2 462.6 450.2 437.1
ACP9593K-3C
85 TR 1253.3 1134.5 1024.4 828.6 742.1 662.8 590.1 523.9 463.6
kW 504.3 511.7 515.7 514.6 510.1 503.4 494.8 484.6 473.0
95 TR 1216.7 1100.6 992.9 801.7 717.4 640.0 569.3 504.7 446.0
kW 599.4 602.2 601.8 592.5 584.3 574.0 562.0 548.6 534.1
105 TR 1179.9 1066.3 961.2 774.6 692.4 617.0 548.2 485.4 428.3
kW 698.1 696.4 691.6 674.2 662.2 648.4 633.1 616.6 599.1
ACP95103K-3C
85 TR 1398.4 1266.2 1143.6 925.7 829.5 741.3 660.5 586.7 519.6
kW 557.8 565.4 569.3 566.9 561.4 553.5 543.4 531.6 518.4
95 TR 1358.5 1229.2 1109.4 896.7 802.9 716.8 638.0 566.2 500.9
kW 662.1 664.5 663.4 651.9 642.2 630.3 616.6 601.3 584.9
105 TR 1358.5 1229.2 1109.4 896.7 802.9 716.8 638.0 566.2 500.9
kW 770.3 767.6 761.5 741.0 727.1 711.3 693.9 675.2 655.6
*For packages with VFD, overspeeding is possible
To estimate capacity and power, use the following factors:
-- 2 compressor package: 1.09
-- 3 compressor package: 1.06
*Para paquetes con variador de velocidad, velocidad excesiva es
posible
Para estimar la capacidad y la potencia, use los siguientes factores:
- Paquete de 2 compresores: 1,09
- Paquete de 3 compresores: 1,06
10 VP-210-1
Performance Data (Low Temp / 60Hz) Datos de Desempeño (Baja Temperatura / 60Hz)
Based on 2°F Suction gas superheat, 5°Subcooling Basado en 2°F Sobrecalentamiento, 5°F Subenfriamiento
Package Model*
Cond
.
Te
mp
Cooling Capacity [TR] Power [kW]
Potencia frigorífica [Toneladas] Potencia [kW]
Modelo* Evaporation Temp °F Temperatura de evaporación °F
°F 10 0 -10 -20 -25 -30 -35 -40 -45
ACP9593K-2C
85 TR 393.4 309.1 239.6 182.9 158.7 136.9 117.3 99.6 83.6
kW 329.9 315.3 298.0 279.5 270.3 261.4 253.1 245.4 238.6
95 TR 379.5 297.4 229.7 174.6 151.0 129.8 110.7 93.4 77.7
kW 374.7 356.1 335.3 313.8 303.4 293.3 284.0 275.4 267.9
105 TR 365.4 285.5 219.8 166.2 143.3 122.6 104.0 87.0 71.6
kW 422.1 399.4 375.1 350.7 339.0 327.9 317.5 308.1 299.9
ACP95103K-2C
85 TR 440.3 346.4 269.0 205.9 178.9 154.6 132.8 113.0 95.1
kW 362.3 345.6 326.0 305.3 295.1 285.3 276.2 267.8 260.6
95 TR 425.4 333.9 258.6 197.1 170.9 147.2 125.8 106.4 88.8
kW 411.1 389.9 366.6 342.7 331.2 320.3 310.1 301.0 293.1
105 TR 425.4 333.9 258.6 197.1 170.9 147.2 125.8 106.4 88.8
kW 462.6 437.1 410.0 383.1 370.3 358.3 347.2 337.2 328.7
ACP9593K-3C
85 TR 590.1 463.6 359.3 274.3 238.0 205.4 176.0 149.4 125.4
kW 494.8 473.0 447.0 419.3 405.5 392.2 379.6 368.0 357.9
95 TR 569.3 446.0 344.6 261.9 226.5 194.7 166.0 140.1 116.5
kW 562.0 534.1 502.9 470.7 455.0 440.0 426.0 413.1 401.9
105 TR 548.2 428.3 329.7 249.3 214.9 183.9 155.9 130.6 107.4
kW 633.1 599.1 562.7 526.1 508.5 491.8 476.3 462.2 449.9
ACP95103K-3C
85 TR 660.5 519.6 403.6 308.8 268.4 232.0 199.1 169.5 142.6
kW 543.4 518.4 489.0 458.0 442.7 428.0 414.3 401.8 390.9
95 TR 638.0 500.9 387.9 295.7 256.3 220.7 188.7 159.6 133.2
kW 616.6 584.9 549.8 514.1 496.9 480.4 465.2 451.5 439.6
105 TR 638.0 500.9 387.9 295.7 256.3 220.7 188.7 159.6 133.2
kW 693.9 655.6 615.0 574.7 555.5 537.4 520.7 505.8 493.0
*For packages with VFD, overspeeding is possible
To estimate capacity and power, use the following factors:
-- 2 compressor package: 1.09
-- 3 compressor package: 1.06
*Para paquetes con variador de velocidad, velocidad excesiva es
posible
Para estimar la capacidad y la potencia, use los siguientes factores:
- Paquete de 2 compresores: 1,09
- Paquete de 3 compresores: 1,06
11 VP-210-1
Performance Data (Low Temp, Economizer / 60Hz) Datos de Desempeño (Baja Temperatura, Economizador / 60Hz)
Based on 2°F Suction gas superheat, 10°F Approach Basado en 2°F Sobrecalientamiento, 10°F Approach
Package Model*
Cond
.
Te
mp
Cooling Capacity [TR] Power [kW]
Potencia frigorífica [Toneladas] Potencia [kW]
Modelo* Evaporation Temp °F Temperatura de evaporación °F
°F 10 0 -10 -20 -25 -30 -35 -40 -45
ACP9593K-2C
85 TR 431.1 345.7 273.1 212.2 185.7 161.7 140.1 120.7 103.3
kW 344.3 332.0 316.3 298.9 290.0 281.3 272.9 265.0 257.9
95 TR 424.6 339.6 267.3 206.7 180.5 156.7 135.3 116.1 99.0
kW 393.8 377.4 358.1 337.5 327.2 317.2 307.6 298.7 290.6
105 TR 417.9 333.2 261.3 201.1 175.1 151.6 130.4 111.5 94.7
kW 446.6 426.0 403.0 379.2 367.5 356.2 345.4 335.4 326.5
ACP95103K-2C
85 TR 486.0 390.1 308.7 240.3 210.6 183.7 159.4 137.5 117.9
kW 379.7 365.8 348.4 329.1 319.2 309.5 300.1 291.3 283.1
95 TR 479.3 383.8 302.7 234.8 205.3 178.6 154.5 132.9 113.5
kW 434.3 415.9 394.5 371.6 360.1 348.9 338.1 328.0 318.7
105 TR 479.3 383.8 302.7 234.8 205.3 178.6 154.5 132.9 113.5
kW 492.5 469.5 443.9 417.4 404.2 391.5 379.3 367.8 357.3
ACP9593K-3C
85 TR 646.6 518.6 409.7 318.2 278.5 242.5 210.1 181.0 155.0
kW 516.4 498.0 474.5 448.4 435.0 421.9 409.3 397.5 386.8
95 TR 637.0 509.4 401.0 310.1 270.7 235.0 202.9 174.2 148.6
kW 590.7 566.1 537.1 506.2 490.8 475.8 461.4 448.0 436.0
105 TR 626.8 499.8 392.0 301.7 262.6 227.4 195.7 167.3 142.1
kW 669.9 639.0 604.5 568.8 551.2 534.2 518.1 503.2 489.7
ACP95103K-3C
85 TR 729.0 585.2 463.0 360.4 315.9 275.5 239.1 206.3 176.9
kW 569.5 548.7 522.6 493.6 478.9 464.3 450.2 436.9 424.7
95 TR 719.0 575.7 454.1 352.2 308.0 267.9 231.8 199.3 170.2
kW 651.4 623.9 591.7 557.4 540.2 523.3 507.1 491.9 478.0
105 TR 719.0 575.7 454.1 352.2 308.0 267.9 231.8 199.3 170.2
kW 738.7 704.3 665.9 626.1 606.4 587.2 568.9 551.7 536.0
*For packages with VFD, overspeeding is possible
To estimate capacity and power, use the following factors:
-- 2 compressor package: 1.09
-- 3 compressor package: 1.06
*Para paquetes con variador de velocidad, velocidad excesiva es
posible
Para estimar la capacidad y la potencia, use los siguientes factores:
- Paquete de 2 compresores: 1,09
- Paquete de 3 compresores: 1,06
12 VP-210-1
Technical Data Datos Técnicos
Package Model Capacity Control
Performance Data* Suction Conn
Discharge Conn
Weight (lbs.)
CFM
Modelo Control del Capacidad
TR KW THR RPM Conexión succión
Conexión descarga
Peso CFM
ACP9593K- 2C 478 390 548 3550
6" 6" 14300 1311
2V 509 414 582 4000 / 3550 14655 1394
ACP95103K- 2C 535 428 613 3550
6" 6" 14300 1463
2V 569 455 652 4000 / 3550 15275 1555
ACP9593K- 3C 717 584 822 3550
6" 6" 18300 1967
3V 763 621 875 4000 / 3550 18655 2050
ACP95103K- 3C 803 642 919 3550
6" 6" 18300 2194
3V 854 683 979 4000 / 3550 19275 2287
ACP9593K- 2C 207 337 243 3550
6" 6" 13898 1311
2V 220 359 259 4000 / 3550 14454 1555
ACP95103K- 2C 235 372 277 3550
6" 6" 13898 1311
2V 250 395 295 4000 / 3550 14454 1555
ACP9593K- 3C 310 506 365 3550
6" 6" 17697 1967
3V 330 538 390 4000 / 3550 18253 2287
ACP95103K- 3C 352 557 415 3550
6" 6" 17697 1967
3V 374 593 444 4000 / 3550 18655 2287
*ACP..K condition = 20°F SST / 95°F SDT / 2°F SH / 5°F SC / Non Economized
*ACP..N condition = -20°F SST / 95°F SDT / 2°F SH / 10°F Approach / Economized
14 VP-210-1
Notes Notas
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
15 VP-210-1
Notes Notas
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....
…………………………………………………………………………………………………………………………………………………………………………………………....