Thank you for your purchase of a Fowler Dial Caliper. Please carefully review this instruction manual to insure proper and accurate use of your new instrument. Precautions • Maintenance & Cleaning Before use, thoroughly remove oil, dust and dirt from the entire surface of the dial caliper. Be sure not to damage the measuring and reference faces. • Zero Point Confirmation Before taking a measurement, clean and close the jaws and check that the dial needle points to "0" on the dial face. • During Use Properly close the caliper on the workpiece. Do not allow dirt, chips, etc., to enter the rack. Otherwise, the rack and pinion could be seriously damaged, resulting in reduced accuracy and improper zero adjustment. Setting Zero Clean both measuring faces of jaw (D) and close caliper to see if the needle points to "0" on the dial face. • If caliper does not zero, loosen the bezel clamp screw (B) and rotate the bezel to the "0" position. • Tighten the bezel clamp screw (B) to fix the "0" position. Readings Inches (1") and tenth inch (.1") measurements can be read on the main scale. • Thousandths (.001") may be read on the dial gage. • One revolution equals .100" Example: Main Scale .800" Dial Indicator .037" Total Value .837" A: Thumbroll B: Bezel Clamp Screw C: Carriage Lock Screw D: Outside Jaws E: Internal Jaws F: Depth Rod G: Step Measurement H: Bezel

Dial Caliper Instructionmedia.hiscoinc.com/Volume2/d110001/medias/docus/201...dial caliper. Be sure not to damage the measuring and reference faces. • Zero Point Confirmation Before

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Dial Caliper Instructionmedia.hiscoinc.com/Volume2/d110001/medias/docus/201...dial caliper. Be sure not to damage the measuring and reference faces. • Zero Point Confirmation Before

Th

ank yo

u fo

r you

r pu

rchase o

f a Fo

wler D

ial Calip

er. P

lease carefully review

this in

structio

n m

anu

al to in

sure

pro

per an

d accu

rate use o

f you

r new

instru

men

t.

Pre

ca

utio

ns

• M

ainten

ance &

Clean

ing

Before use, thoroughly rem

ove oil, dust and dirt from the entire surface of the

dial caliper. Be sure not to dam

age the measuring and reference faces.

• Z

ero P

oin

t Co

nfi

rmatio

n B

efore taking a measurem

ent, clean and close the jaws and check that the dial

needle points to "0" on the dial face.

• D

urin

g U

se P

roperly close the caliper on the workpiece. D

o not allow dirt, chips, etc., to

enter the rack. Otherw

ise, the rack and pinion could be seriously damaged,

resulting in reduced accuracy and improper zero adjustm

ent.

Se

tting

Ze

ro •

Clean both m

easuring faces of jaw (D

) and close caliper to see if the needle points to "0" on the dial face. • If caliper does not zero, loosen the bezel clam

p screw (B

) and rotate the bezel to the "0" position. • T

ighten the bezel clamp screw

(B) to fix the "0" position.

Re

ad

ing

s •

Inches (1") and tenth inch (.1") measurem

ents can be read on the main scale.

• Thousandths (.001") m

ay be read on the dial gage. • O

ne revolution equals .100"

Exam

ple:

Main S

cale .800"

Dial Indicator

.037"Total V

alue .837"

A: T

humbroll

B: B

ezel Clam

p Screw

C: C

arriage Lock Screw

D: O

utside Jaws

E: Internal Jaw

sF

: Depth R

odG

: Step M

easurement

H: B

ezel

Th

ank yo

u fo

r you

r pu

rchase o

f a Fo

wler D

ial Calip

er. P

lease carefully review

this in

structio

n m

anu

al to in

sure

pro

per an

d accu

rate use o

f you

r new

instru

men

t.

Pre

ca

utio

ns

• M

ainten

ance &

Clean

ing

Before use, thoroughly rem

ove oil, dust and dirt from the entire surface of the

dial caliper. Be sure not to dam

age the measuring and reference faces.

• Z

ero P

oin

t Co

nfi

rmatio

n B

efore taking a measurem

ent, clean and close the jaws and check that the dial

needle points to "0" on the dial face.

• D

urin

g U

se P

roperly close the caliper on the workpiece. D

o not allow dirt, chips, etc., to

enter the rack. Otherw

ise, the rack and pinion could be seriously damaged,

resulting in reduced accuracy and improper zero adjustm

ent.

Se

tting

Ze

ro •

Clean both m

easuring faces of jaw (D

) and close caliper to see if the needle points to "0" on the dial face. • If caliper does not zero, loosen the bezel clam

p screw (B

) and rotate the bezel to the "0" position. • T

ighten the bezel clamp screw

(B) to fix the "0" position.

Re

ad

ing

s •

Inches (1") and tenth inch (.1") measurem

ents can be read on the main scale.

• Thousandths (.001") m

ay be read on the dial gage. • O

ne revolution equals .100"

Exam

ple:

Main S

cale .800"

Dial Indicator

.037"Total V

alue .837"

A: T

humbroll

B: B

ezel Clam

p Screw

C: C

arriage Lock Screw

D: O

utside Jaws

E: Internal Jaw

sF

: Depth R

odG

: Step M

easurement

H: B

ezel

Joe
Text Box
DISTRIBUTED BY: All-Spec Industries 1-800-537-0351 (phone) Wilmington, NC 1-800-379-9903 (fax) www.all-spec.com [email protected]