MANUAL BALL VALVES Tag Nº: BV-101 P&ID: PWT PID Line No.: Non-Flashing Flashing Erosive Corrosive With Solids Liquid Gas St 1. Fluid Crude oil Service: Crude oil Units Maximum Normal Min 2. Flow Rate BFPD 2,435 2,000.0 3. Inlet Pressure Psig 300 Psig 150 Psig 50 4. Outlet Pressure Psig 300 Psig 150 Psig 50 5. Inlet Temperature DegF 300 200 1 6. Specific Gravity 0.834 0.834 0. 7. Viscosity cP 0.58 0.58 0 Specific heat rati Cp/Cv (gamma) NA NA 8. bar(a) NA NA Compressibility factor z 0.898 0.898 0. Critical pressure Pc bar(a) NA NA 9. Travel % NA NA 10. C.V. C.V. NA NA 11. Noise level dBA NA MA 13. Size-Inches & IN 3" SCH80 53. Type Manual 14. Schedule OUT 3" SCH80 54. Mfr & Model NA 15. Pipe line Insulati NONE 55. Size NA Eff Area NA 16. Type TRUNNION BALL VALVE 56. On/Off Modulating 17. FULL BORE 57. Spring Action Open Close Maintain Last Posit 18. Size REFER LIST ATTACHED 58. Max Allowable Pressure NA 19. Mfr & Model Vendor to advice 59. Min Required Pressure NA 20. Body/Bonnet Matl ASTM A216 60. Available Air Supply Pressure: Max NA 21. Liner Yes No Matl 61. Min. NA 22. End. In 3" ANSI 300# RF FLANGE 62. Bench Range NA 23. Conn. Out 3" ANSI 300# RF FLANGE 63. Actuator Orientation STD Other VERTICAL STE 24. Flg Face Finish Vendor to advice 64. Handwheel Yes No Type NA 25. End Ext. Yes No Matl 65. Air Failure Valve Yes No Set at NA 26. Flow Direction BI-DIRECTIONAL 66. Max. Diff. pressure valve should withstan NA 27. Type of Bonnet STANDARD 67. Input Signal NA 28. Lub & Iso Valve Yes No 68. Type NA Lube 69. Mfr & Model NA 29. Packing Material VITON 70. On Incr Signal Output Incr Decr 30. Packing Type O - RING 71. Gauges By-pass 32. Type FULL BORE BALL 72. Cam Characteristic EL Conn. NA 33. Size (mm) FULL Rated Travel 90 DEG. 73. Explosion protection NA 34. Characteristic ON / OFF 74. Type Qty 35. Seats 1 2 Balanced Unbal 75. Mfr & Model 36. Rated Cv NA NA -- 76. Contacts/Rating 37. Ball Matl. SS 316 77. Actuation Points Valve open Valve Shut 38. Seat Material PTFE 78. Soft Seat Yes No Matl 79. Mfr & Model NA 39. Cage/Guide Materia NA 80. Set Pressure NA 40. Stem/Shaft Materia SS 316 81. Filter Gauges NA SPECIALS/ACCESSORIES 83. Hydro Pressure YES 43. Area classificatio NA 84. ANSI/FCI Leakage Class : Explosion proof Four Five Six (Bubble Tight) Notes: 1 VALVES ARE TWO PIECES BOLTED BODY OF FORGED LF2 MATERIAL 2 TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS 3 FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS 4 FIRESAFE DESIGN TO API 607 5 BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM 6 SEAT SPRING MATERIAL: INCONEL X750 DR DATE TITLE: MANUAL BALL VALVE CHK DATE PROJECT NAME: B For Consruction METERING SYSTEM JAVA MANIS A For Approval APP DATE DOC. NO. Vapor Pressure Pv FL XT TRIM VALVE BODY / BONNET LINE SERVICE CONDITIONS { ACTUATOR TEST AIRSET SWITCHES POSITIONER

Design Economic Sewage Treatment Plant

Embed Size (px)

DESCRIPTION

sewage treatment plant (STP)

Citation preview

Page 1: Design Economic Sewage Treatment Plant

MANUAL BALL VALVES

Tag Nº: BV-101 P&ID: PWT PID Line No.:

Non-Flashing Flashing Erosive Corrosive With Solids Liquid Gas Steam

1. Fluid Crude oil Service: Crude oil

Units Maximum Normal Minimum

2. Flow Rate BFPD 2,435 2,000.0 -

3. Inlet Pressure Psig 300 Psig 150 Psig 50 Psig

4. Outlet Pressure Psig 300 Psig 150 Psig 50 Psig

5. Inlet Temperature DegF 300 200 100

6. Specific Gravity 0.834 0.834 0.834

7. Viscosity cP 0.58 0.58 0.58

Specific heat ratio Cp/Cv (gamma) NA NA NA

8. bar(a) NA NA NA

Compressibility factor z 0.898 0.898 0.898

Critical pressure Pc bar(a) NA NA NA

9. Travel % NA NA NA

10. C.V. C.V. NA NA NA

11. Noise level dBA NA MA NA

13. Size-Inches & IN 3" SCH80 53. Type Manual

14. Schedule OUT 3" SCH80 54. Mfr & Model NA

15. Pipe line Insulation NONE 55. Size NA Eff Area NA

16. Type TRUNNION BALL VALVE 56. On/Off Modulating

17. FULL BORE 57. Spring Action Open Close Maintain Last Position

18. Size REFER LIST ATTACHED 58. Max Allowable Pressure NA

19. Mfr & Model Vendor to advice 59. Min Required Pressure NA

20. Body/Bonnet Matl ASTM A216 60. Available Air Supply Pressure: Max NA

21. Liner Yes No Matl 61. Min. NA

22. End. In 3" ANSI 300# RF FLANGE 62. Bench Range NA

23. Conn. Out 3" ANSI 300# RF FLANGE 63. Actuator Orientation STD Other VERTICAL STEM

24. Flg Face Finish Vendor to advice 64. Handwheel Yes No Type NA

25. End Ext. Yes No Matl 65. Air Failure Valve Yes No Set at NA

26. Flow Direction BI-DIRECTIONAL 66. Max. Diff. pressure valve should withstand NA

27. Type of Bonnet STANDARD 67. Input Signal NA

28. Lub & Iso Valve Yes No 68. Type NA

Lube 69. Mfr & Model NA

29. Packing Material VITON 70. On Incr Signal Output Incr Decr

30. Packing Type O - RING 71. Gauges By-pass

32. Type FULL BORE BALL 72. Cam Characteristic EL Conn. NA

33. Size (mm) FULL Rated Travel 90 DEG. 73. Explosion protection NA

34. Characteristic ON / OFF 74. Type Qty

35. Seats 1 2 Balanced Unbal 75. Mfr & Model

36. Rated Cv NA NA -- 76. Contacts/Rating

37. Ball Matl. SS 316 77. Actuation Points Valve open Valve Shut

38. Seat Material PTFE 78.

Soft Seat Yes No Matl 79. Mfr & Model NA

39. Cage/Guide Material NA 80. Set Pressure NA

40. Stem/Shaft Material SS 316 81. Filter Gauges NA

SPECIALS/ACCESSORIES 83. Hydro Pressure YES

43. Area classification: NA 84. ANSI/FCI Leakage Class :

Explosion proof Four Five Six (Bubble Tight)

Notes: 1 VALVES ARE TWO PIECES BOLTED BODY OF FORGED LF2 MATERIAL

2 TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS

3 FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

4 FIRESAFE DESIGN TO API 607

5 BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM

6 SEAT SPRING MATERIAL: INCONEL X750

DR DATE TITLE: SHT. NO.

MANUAL BALL VALVE

CHK DATE PROJECT NAME:

B For Consruction METERING SYSTEM JAVA MANIS CONT'D

A For Approval APP DATE DOC. NO. SHT. NO.

Vapor Pressure Pv

FL XT

TR

IMV

ALV

E B

OD

Y /

BO

NN

ET

LIN

ES

ER

VIC

E C

ON

DIT

ION

S

{

AC

TU

AT

OR

TE

ST

AIR

SE

TS

WIT

CH

ES

PO

SIT

ION

ER

Page 2: Design Economic Sewage Treatment Plant

REV DATE DESCRIPTION REV BY CHK BY

MANUAL BALL VALVESLIST OF TAG NUMBERS

QTY Tag Nº: Service Size8 HV 104 NATURAL GAS 6" ANSI RF 300#

HV 105

Notes:

DR DATE TITLE: SHT. NO.

MANUAL BALL VALVE

CHK DATE PROJECT NAME:

B For Consruction METERING SYSTEM JAVA MANIS CONT'D

A For Approval APP DATE DOC. NO. SHT. NO.

REV DATE DESCRIPTION REV BY CHK BY

Page 3: Design Economic Sewage Treatment Plant
Page 4: Design Economic Sewage Treatment Plant

MANUAL BALL VALVES

Tag Nº: HV - 101 - 102 - 103 P&ID: Line No.:

Non-Flashing Flashing Erosive Corrosive With Solids Liquid

1. Fluid NATURAL GAS Service: NATURAL GAS

Units Maximum Normal

2. Flow Rate MMSCFD 3,5 2.5

3. Inlet Pressure Psig 300 Psig 150 Psig

4. Outlet Pressure Psig 100 Psig 75 Psig

5. Inlet Temperature DegC 90 82

6. Specific Gravity 0.69498 0.69498

7. Viscosity cP 0.01251 0.01251

Specific heat ratio Cp/Cv (gamma) 1.2894 1.2894

8. bar(a) NA NA

Compressibility factor z 0.981025 0.981025

Critical pressure Pc bar(a) NA NA

9. Travel % NA NA

10. C.V. C.V. NA NA

11. Noise level dBA NA MA

13. Size-Inches & IN 3" SCH40 53. Type LEVER

14. Schedule OUT 3" SCH40 54. Mfr & Model Crane

15. Pipe line Insulation NONE 55. Size NA

16. Type TRUNNION BALL VALVE 56. On/Off Modulating

17. FULL BORE 57. Spring Action Open Close

18. Size REFER LIST ATTACHED 58. Max Allowable Pressure19. Mfr & Model KTM 59. Min Required Pressure20. Body/Bonnet Matl ASTM A105N 60. Available Air Supply Pressure:21. Liner Yes No Matl 61.

22. End. In 3" ANSI 300# RF FLANGE 62. Bench Range

23. Conn. Out 3" ANSI 300# RF FLANGE 63. Actuator Orientation STD

24. Flg Face Finish SERRATED RA 3.2 64. Handwheel Yes No

25. End Ext. Yes No Matl 65. Air Failure Valve Yes No

26. Flow Direction BI-DIRECTIONAL 66. Max. Diff. pressure valve should withstand

27. Type of Bonnet STANDARD 67. Input Signal NA

28. Lub & Iso Valve Yes No 68. Type NA

Lube 69. Mfr & Model NA

29. Packing Material VITON 70. On Incr Signal Output

30. Packing Type O - RING 71. Gauges

32. Type FULL BORE BALL 72. Cam Characteristic

33. Size (mm) FULL Rated Travel 90 DEG. 73. Explosion protection NA

34. Characteristic ON / OFF 74. Type Qty

35. Seats 1 2 Balanced Unbal 75. Mfr & Model

36. Rated Cv NA NA -- 76. Contacts/Rating

37. Ball Matl. SS 316 77. Actuation Points Valve open

38. Seat Material R - PTFE 78.

Soft Seat Yes No Matl 79. Mfr & Model NA

39. Cage/Guide Material NA 80. Set Pressure NA

40. Stem/Shaft Material SS 316 81. Filter Gauges

SPECIALS/ACCESSORIES 83. Hydro Pressure YES

43. Area classification: NA 84. ANSI/FCI Leakage Class :

Explosion proof Four Five

Vapor Pressure Pv

FL XT

TR

IMV

ALV

E B

OD

Y /

BO

NN

ET

LIN

ES

ER

VIC

E C

ON

DIT

ION

S

{

AC

TU

AT

OR

TE

ST

AIR

SE

TS

WIT

CH

ES

PO

SIT

ION

ER

Page 5: Design Economic Sewage Treatment Plant

Notes: 1 VALVES ARE THREE PIECES BOLTED BODY OF FORGED LF2 MATERIAL

2 TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS

3 FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

4 FIRESAFE DESIGN TO API 607

5 FINAL TEST AND INSPECTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

6 BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM

7 SEAT SPRING MATERIAL: INCONEL X750

DR DATE TITLE:

MANUAL BALL VALVE

CHK DATE PROJECT NAME:

B For Consruction METERING SYSTEM JAVA MANIS

A For Approval APP DATE DOC. NO.

REV DATE DESCRIPTION REV BY CHK BY

MANUAL BALL VALVESLIST OF TAG NUMBERS

QTY Tag Nº: Service8 HV 101 NATURAL GAS

HV 102

HV 103

Page 6: Design Economic Sewage Treatment Plant

Notes:

DR DATE TITLE:

MANUAL BALL VALVE

CHK DATE PROJECT NAME:

B For Consruction METERING SYSTEM JAVA MANIS

A For Approval APP DATE DOC. NO.

REV DATE DESCRIPTION REV BY CHK BY

Page 7: Design Economic Sewage Treatment Plant

MANUAL BALL VALVES

Gas Steam

Normal Minimum

2.5 0.5

150 Psig 50 Psig

75 Psig 50 Psig

82 77

0.69498 0.69498

0.01251 0.01251

1.2894 1.2894

NA NA

0.981025 0.981025

NA NA

NA NA

NA NA

MA NA

LEVER

Crane

Eff Area NA

Maintain Last Position

NA

NA

Max NA

Min. NA

NA

Other VERTICAL STEM

Type NA

Set at NA

NA

NA

NA

NA

Incr Decr

By-pass

EL Conn. NA

NA

Valve Shut

NA

NA

Gauges NA

YES

Six (Bubble Tight)

Page 8: Design Economic Sewage Treatment Plant

VALVES ARE THREE PIECES BOLTED BODY OF FORGED LF2 MATERIAL

TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS

FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

FIRESAFE DESIGN TO API 607

FINAL TEST AND INSPECTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM

SEAT SPRING MATERIAL: INCONEL X750

SHT. NO.

MANUAL BALL VALVE

METERING SYSTEM JAVA MANIS CONT'D

SHT. NO.

MANUAL BALL VALVESLIST OF TAG NUMBERS

Size3" ANSI RF 300#

Page 9: Design Economic Sewage Treatment Plant

SHT. NO.

MANUAL BALL VALVE

METERING SYSTEM JAVA MANIS CONT'D

SHT. NO.

Page 10: Design Economic Sewage Treatment Plant

MANUAL BALL VALVES

Tag Nº: HV - 106 - 107 P&ID: Line No.:

Non-Flashing Flashing Erosive Corrosive With Solids Liquid

1. Fluid NATURAL GAS Service: NATURAL GAS

Units Maximum Normal

2. Flow Rate MMSCFD 3,5 2.5

3. Inlet Pressure Psig 300 Psig 150 Psig

4. Outlet Pressure Psig 100 Psig 75 Psig

5. Inlet Temperature DegC 90 82

6. Specific Gravity 0.69498 0.69498

7. Viscosity cP 0.01251 0.01251

Specific heat ratio Cp/Cv (gamma) 1.2894 1.2894

8. bar(a) NA NA

Compressibility factor z 0.981025 0.981025

Critical pressure Pc bar(a) NA NA

9. Travel % NA NA

10. C.V. C.V. NA NA

11. Noise level dBA NA MA

13. Size-Inches & IN 4" SCH40 53. Type LEVER

14. Schedule OUT 4" SCH40 54. Mfr & Model Crane

15. Pipe line Insulation NONE 55. Size NA

16. Type TRUNNION BALL VALVE 56. On/Off Modulating

17. FULL BORE 57. Spring Action Open Close

18. Size REFER LIST ATTACHED 58. Max Allowable Pressure19. Mfr & Model KTM 59. Min Required Pressure20. Body/Bonnet Matl ASTM A105N 60. Available Air Supply Pressure:21. Liner Yes No Matl 61.

22. End. In 4" ANSI 300# RF FLANGE 62. Bench Range

23. Conn. Out 4" ANSI 300# RF FLANGE 63. Actuator Orientation STD

24. Flg Face Finish SERRATED RA 3.2 64. Handwheel Yes No

25. End Ext. Yes No Matl 65. Air Failure Valve Yes No

26. Flow Direction BI-DIRECTIONAL 66. Max. Diff. pressure valve should withstand

27. Type of Bonnet STANDARD 67. Input Signal NA

28. Lub & Iso Valve Yes No 68. Type NA

Lube 69. Mfr & Model NA

29. Packing Material VITON 70. On Incr Signal Output

30. Packing Type O - RING 71. Gauges

32. Type FULL BORE BALL 72. Cam Characteristic

33. Size (mm) FULL Rated Travel 90 DEG. 73. Explosion protection NA

34. Characteristic ON / OFF 74. Type Qty

35. Seats 1 2 Balanced Unbal 75. Mfr & Model

36. Rated Cv NA NA -- 76. Contacts/Rating

37. Ball Matl. SS 316 77. Actuation Points Valve open

38. Seat Material R - PTFE 78.

Soft Seat Yes No Matl 79. Mfr & Model NA

39. Cage/Guide Material NA 80. Set Pressure NA

40. Stem/Shaft Material SS 316 81. Filter Gauges

SPECIALS/ACCESSORIES 83. Hydro Pressure YES

43. Area classification: NA 84. ANSI/FCI Leakage Class :

Explosion proof Four Five

Vapor Pressure Pv

FL XT

TR

IMV

ALV

E B

OD

Y /

BO

NN

ET

LIN

ES

ER

VIC

E C

ON

DIT

ION

S

{

AC

TU

AT

OR

TE

ST

AIR

SE

TS

WIT

CH

ES

PO

SIT

ION

ER

Page 11: Design Economic Sewage Treatment Plant

Notes: 1 VALVES ARE THREE PIECES BOLTED BODY OF FORGED LF2 MATERIAL

2 TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS

3 FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

4 FIRESAFE DESIGN TO API 607

5 FINAL TEST AND INSPECTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

6 BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM

7 SEAT SPRING MATERIAL: INCONEL X750

DR DATE TITLE:

MANUAL BALL VALVE

CHK DATE PROJECT NAME:

B For Consruction METERING SYSTEM JAVA MANIS

A For Approval APP DATE DOC. NO.

REV DATE DESCRIPTION REV BY CHK BY

MANUAL BALL VALVESLIST OF TAG NUMBERS

QTY Tag Nº: Service8 HV 106 NATURAL GAS

HV 107

Page 12: Design Economic Sewage Treatment Plant

Notes:

DR DATE TITLE:

MANUAL BALL VALVE

CHK DATE PROJECT NAME:

B For Consruction METERING SYSTEM JAVA MANIS

A For Approval APP DATE DOC. NO.

REV DATE DESCRIPTION REV BY CHK BY

Page 13: Design Economic Sewage Treatment Plant

MANUAL BALL VALVES

Gas Steam

Normal Minimum

2.5 0.5

150 Psig 50 Psig

75 Psig 50 Psig

82 77

0.69498 0.69498

0.01251 0.01251

1.2894 1.2894

NA NA

0.981025 0.981025

NA NA

NA NA

NA NA

MA NA

LEVER

Crane

Eff Area NA

Maintain Last Position

NA

NA

Max NA

Min. NA

NA

Other VERTICAL STEM

Type NA

Set at NA

NA

NA

NA

NA

Incr Decr

By-pass

EL Conn. NA

NA

Valve Shut

NA

NA

Gauges NA

YES

Six (Bubble Tight)

Page 14: Design Economic Sewage Treatment Plant

VALVES ARE THREE PIECES BOLTED BODY OF FORGED LF2 MATERIAL

TRUNNION MOUNTED BALL WITH SELF RELIEVING SEATS

FULL BORE DESIGN AND CONSTRUCTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

FIRESAFE DESIGN TO API 607

FINAL TEST AND INSPECTION IN ACCORDANCE WITH API 6D SPECIFICATIONS

BODY STUD / STUD NUTS MATERIAL: ASTM A193-B7M / A194-2HM

SEAT SPRING MATERIAL: INCONEL X750

SHT. NO.

MANUAL BALL VALVE

METERING SYSTEM JAVA MANIS CONT'D

SHT. NO.

MANUAL BALL VALVESLIST OF TAG NUMBERS

Size4" ANSI RF 300#

Page 15: Design Economic Sewage Treatment Plant

SHT. NO.

MANUAL BALL VALVE

METERING SYSTEM JAVA MANIS CONT'D

SHT. NO.

Page 16: Design Economic Sewage Treatment Plant

BAK SEPTIC TANK

Dimensi Bak Septic Tank

Jumlah = 1 unit #VALUE! #VALUE! hariVolume = #VALUE! m3 40.5Panjang = 9.00 mLebar = 4.50 mTinggi = 3.70 mFree board 0.30 m

Unit tambahan untuk proses di Bak Septic Tank

Pompa tran*Jumlah 2 unit*Jenis Submersible pump*Kapasitas/ 15 liter/min #VALUE!*Head 6 m Aqua

BAK ANAEROBIC

Dimensi Bak Anaerobic

Jumlah = 2 unitVolume = 104.77 m3 55 #VALUE! hari Panjang = 7.4 m 37.4Lebar = 2.4 m 17.8Tinggi = 2.8 mFree board 0.7 m

Unit tambahan untuk proses di Bak Anaerob

Packing *Jumlah*Jenis Batu split*Ukuran 40 mm x 80 mm

SAND FILTER

Jumlah = 2 unitVolume = 50.97 m3 67.07 66.89Panjang = 11.60 m 67.28 #VALUE! hariLebar = 5.80 mTinggi = 0.76 m

Silica sand*Jumlah 63713 kg*Ukuran

*Jumlah 2 unit*Jenis Submersible pump*Kapasitas 15 liter/min*Head 18 m Aqua

Page 17: Design Economic Sewage Treatment Plant

No. Prosp : General D : Limbah c 15.12 m3/hariDate :

BAK SEPTIC TANK

Dimensi Bak Septic Tank

Jumlah = 1 unit 40.9 10 hariVolume = 151.20 m3 40.5Panjang = 9.00 mLebar = 4.50 mTinggi = 3.70 mFree board 0.30 m

Unit tambahan untuk proses di Bak Septic Tank

Pompa tran*Jumlah 2 unit*Jenis Submersible pump*Kapasitas/ 15 liter/min 11*Head 6 m Aqua

BAK ANAEROBIC

Dimensi Bak Anaerobic

Jumlah = 2 unitVolume = 104.77 m3 55 6.93 hari Panjang = 7.4 m 37.4Lebar = 2.4 m 17.8Tinggi = 2.8 mFree board 0.7 m

Unit tambahan untuk proses di Bak Anaerob

Packing *Jumlah*Jenis Batu split*Ukuran 40 mm x 80 mm

SAND FILTER

Jumlah = 2 unitVolume = 50.97 m3 67.07 66.89Panjang = 11.60 m 67.28 3.37 hariLebar = 5.80 mTinggi = 0.76 m

Silica sand*Jumlah 63713 kg*Ukuran

Page 18: Design Economic Sewage Treatment Plant

*Jumlah 2 unit*Jenis Submersible pump*Kapasitas 15 liter/min*Head 18 m Aqua